0% found this document useful (0 votes)
31 views1 page

Certificate

The document is a certificate of test and examination for a full body harness manufactured by Paharpur Cooling Towers Ltd, confirming compliance with IS 3521 (Part-1):2021 and EN 361:2002 standards. It details the results of various tests including dynamic performance, static strength, and corrosion resistance, all of which were successfully passed. The harness model is TANGO-II+SHAB, with a batch quantity of 100 pieces, dated 21-10-2024.

Uploaded by

Omkar Mishra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views1 page

Certificate

The document is a certificate of test and examination for a full body harness manufactured by Paharpur Cooling Towers Ltd, confirming compliance with IS 3521 (Part-1):2021 and EN 361:2002 standards. It details the results of various tests including dynamic performance, static strength, and corrosion resistance, all of which were successfully passed. The harness model is TANGO-II+SHAB, with a batch quantity of 100 pieces, dated 21-10-2024.

Uploaded by

Omkar Mishra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

IS 3521 (Part-1):2021

Certificate
CM/L No. 1573759 OF TEST AND EXAMINATION OF FULL BODY HARNESS

Certificate No. PL24Y-05154-2011 Date: 21-10-2024

M/S. PAHARPUR COOLING TOWERS LTD

Gujarat

This is to certify that the full body harness manufactured against your
order and as listed below has been tested and found according to Test as
per IS 3521 (Part1) :2021 & EN 361:2002
Sr.
TYPE OF TEST METHOD RESULT
No.

1. Dynamic performance test The harness is fitted to a 100 kg torso The harness holds the
dummy and released from 4 m. Test dummy following both
conducted twice on each attachment point drops

2. Static strength test The harness is subjected to a tensile load The harness withstands
of 15 kN for 3 minutes the test

3. Corrosion resistance test All metallic components shall be exposed The components do not
to the neutral salt spray test for a period of show any traces of rust
24 h followed by one hour drying, followed
by an additional exposure of 24 h

Model : TANGO-II+SHAB, SUSP, 1.8, 2LL, BR, SH-60 HOOK

Batch No. : T21024 Qty : 100 pcs.

Invoice No. : PL24Y-05154 Date: 21-10-2024

Quality-Inspector

Udyogi International Pvt Ltd


294 B B Ganguly Street, 2nd Floor, Kolkata-700012, West Bengal, India
Email - qc@Udyogi.net