LED Strobe Warning Lights for Heavy Equipment
QA70HLS/ QA100HLS
30 50
66
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications Product Specifications
QA100HLS - 12/24 - R Model number Voltage Current Certificate Weight Color
[Model number] [Voltage] [Color]
QA70HLS Max.650mA - 0.23kg
| | |
R-Red
DC12V-24V
• QA70HLS • 12/24-DC12V-24V R-Red A-Amber
• QA100HLS A-Amber QA100HLS Max.1.2A 0.39kg
※ CE compliant : DC12V-24V(QA100HLS)
• Protection rating : IP66
• Ambient operating temperature : -30°C to + 50°C
Please scan the QR code for more
detailed product information.
www.qlight.com
1
Dimensions (Units : mm)
QA70HLS QA100HLS
Ø72
Ø9 CABLE ENTRY
86
92
108
113
22
15
14
93
Ø101
360 ° /3-M4 BOLT PCD 60
2-Ø6.5 HOLES(Slot hole)
24.5
8.5
6.5
PCD 91~95
112 FITTING HOLES Ø10
CABLE ENTRY
Wiring Instructions
DC
Red • QA70HLS model : External power line - UL1015 AWG18(0.75sq) × 2C 400mm
Black Fuse Power • QA100HLS model : External power line - KSC3304 0.85sq × 2C 400mm
• These products can be wired regardless of polarity.
Parts Definition/ Installation
■Parts Definition ■Installation
QA70HLS QA100HLS • First, machine taps or holes on the mounting surface.• The
mounting hole of this product is 5.4mm(QA70HLS),
9mm(QA100HLS) in diameter.• When machining taps, fasten the
bolt through the mounting hole
Lens(PC) of the product(QA70HLS only).
• When machining holes, insert the bolt through the hole of the
product, and tighten the nut from the opposite side of the
mounting surface.
LED
Housing (ABS+GF)
Housing (ABS)
2
Mounting Hole Specification
• Machine holes on the mounting surface referring to the diagram below.
Min.Ø5 CABLE ENTRY
2-Ø7 HOLES 91~95
3-Ø5 HOLES
PCD 60
QA70HLS QA100HLS
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP66), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
• For further information, please visit our website (www.qlight.com).
3
Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement.
For your safety The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
Qlight Co., Ltd. www.qlight.com | trade@qlight.com
Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com
China Factory/ Shanghai Sales Office | #Room 333 Building B, #11, Lane 450, Zhenda Road, Baoshan District, Shanghai, China
Tel. +86 - 21 - 6651 - 7100 Fax. +86 - 21 - 6315 - 3929
China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China
Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
www.qlight.com
EN - QA70HLS - 2405A