0% found this document useful (0 votes)
67 views6 pages

TD Series

The user manual provides detailed instructions for the TD/JTB series precision balance, including specifications, features, and operational guidelines. It covers assembly, calibration, weighing, taring, and piece counting, along with troubleshooting tips. The balance operates on high precision strain gauge load cells and is designed for high reliability and quick stabilization.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views6 pages

TD Series

The user manual provides detailed instructions for the TD/JTB series precision balance, including specifications, features, and operational guidelines. It covers assembly, calibration, weighing, taring, and piece counting, along with troubleshooting tips. The balance operates on high precision strain gauge load cells and is designed for high reliability and quick stabilization.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

User Manual

FOR TD/JTB SERIES PRECISION


BALANCE

Please read operating manual before installation and operation.

Drawell International Technology Limited


Shanghai Drawell Scientific Instrument Co.,Ltd

Add : Suite 1506,Lane581 XiuChuan Rd.,PuDong New Area,Shanghai,China


Tel: 0086 21 50966080
Fax: 0086 21 50966080
Web : www.drawell.com.cn
Email : sales01@drawell.com.cn
TD/JTB series precision balance works on high precision strain gauge
load cell which implements high speed stabilization and high reliability.

Specifications,

Model No. (JTB) 1003 2003 3003


Max. Capacity (g) 0-100 0-200 0-300
Tare Range (g) 100 200 300
Readability 0.001
Repeatability (g) +/-0.001 +/-0.001 +/-0.002
Non-Linearity (g) +/-0.001 +/-0.001 +/-0.002
Corner Error (g) +/-0.001 +/-0.001 +/-0.002
Pan Size (mm) ∮90mm
Dimensions (LxWxH) 295x192x280mm
Power supply AC 110-120V/220-240V

Model No. (TD) 3002 6002 10002 20002 30002 50002


Max. Capacity (g) 0-300 0-600 0-1000 0-2000 0-3000 0-5000
Tare Range (g) 300 600 1000 2000 3000 5000
Readability 0.01
Pan Size (mm) ∮125mm 170*170mm
Dimensions (LxWxH) 265x200x80mm
Power supply AC 110-120V/220-240V

Model No. (TD) 3001 1001 12001 30001 50001 100001


Max. Capacity (g) 0-300 0-100 0-1200 0-3000 0-5000 0-10000
Tare Range (g) 300 1000 1200 3000 5000 10000
Readability 0.1
Pan Size (mm) ∮125mm 170*170mm
Dimensions (LxWxH) 265x200x80mm
Power supply AC 110-120V/220-240V

Model No. (TD) 1000 2000 3000 4000 5000 10000


Max. Capacity (g) 0-1000 0-2000 0-3000 0-4000 0-5000 0-10000
Tare Range (g) 1000 2000 3000 4000 5000 10000
Readability 1
Pan Size (mm) ∮125mm 170*170mm
Dimensions (LxWxH) 265x200x80mm
Power supply AC 110-120V/220-240V
Operating Temperature Range: 5-35 Degree Centigrade
Moisture: 50-85%
Function Keys,
TARE, to tare
CAL, to calibrate
PCS, for counting

Features,
 High Precision Loadcell
 Aluminum Alloy die cast base, Plastic case
 Stainless Steel Platter
 Super Bright easy to read contrast LED display
 Height adjustable feet
 RS232 Interface Optional
 Full Capacity Taring
 Simple 3 keys menu for easy operation
 Stabilization time 1-1.5 seconds typically
 Overload Protection
 Below Balance Weighing Facility
 Checking Weighing, Piece counting function

ASSEMBLING
 Unpack the package, put the platter on the top of the loader.
 Put the balance on a steady flat surface away from vibration, direct
sunshine ,air blow or strong magnetic disturbance..

TURN ON THE BALANCE


Connect the balance to power supply, keep the switch in the ON(-) status.
the balance will in turns display following figures,
8.8.8.8.8.8.
Maximum capacity
------------
Finally the balance stays in a standby state of showing 0.0g,0.00g or 0.000g in
the display

Notice: the lasting time of --------- will be decided by the stability of the loadcell,
thus, the balance must not be located in an unstable surface or in the wind
blow.
CALIBRATION
 The purpose for this operation is to calibrate the balance so as to achieve
the best performance in case there is obvious tolerance error in weighing
or the balance is located in different gravity due to different latitude.
 it is suggested to warm up the balance over half an hour before calibration.
 Remove all loads from the platter, press key TARE to clear the readings to
0.0g,0.00g or 0.000g.
 Press and hold key CAL for 3 seconds, release the key CAL when
“---CAL---“ is shown in the display, a figure of standard weight will flash in
the display, put a standard weight on the platter accordingly, standby state
“------“ will be shown in the display for a few seconds before the standard
weight figure is shown in the display, remove the weight, “------“ standby
state will remain for a few seconds before the balance enter stable
weighing mode, showing 0.0g ,0.00g or 0.000g.
 It is recommended to make the operations twice to achieve the best
calibration result.
 Linearity Calibration, Press and hold key CAL for 3 seconds, release the
key CAL when “---CAL---“ is shown in the display, after a short presence of
“- - - - “, a standard weight figure will flash in the display, press and hold
key PCS to enter linearity calibration mode, follow the instructions to
proceed linearity calibration.

WEIGHING
When the balance is warmed up and calibrated, 0.0g,0.00g or 0.000g is shown
in the display indicating weighing mode, put the object on the platter, when
stable, the weight of the object is shown in the display.

TARING
When a loader is put over the platter, its weight is shown in the display, press
key TARE, 0.0g ,0.00g or 0.000g will be shown in the display, indicating the
weight of the loader is deducted, put the object into the loader, when stable,
the figure shown in the display is the weight of the object.

PIECE COUNTING
Remove all loads from the platter, press key TARE to clear the readings in the
display, press key PCS to enter counting mode, “- -COU- -“ “- - - -“ and figure
10(default sampling quantity) will in turns be shown in the display, press key
CAL to select sampling quantity from 10,25,50,100 up to 500,release key CAL
when the desired quantity flashes in the display, put a sample on the platter
accordingly, press key PCS again to save setting, the counting mode setting is
finished, in counting mode, weighing unit will change from g to PCS.
Notice: In counting mode, the weight of the sampling objects should be even,
the weight of the individual sample should not be less than the division of the
balance.
Return to Weighing Mode: Press key PCS to return to Weighing mode.

OVERLOAD
The weight of the objective cannot exceed the rated maximum capacity of the
balance, when exceeding, “-------“ will be shown in the display, remove the
objective immediately from the platter so as to prevent damages to the
balance.

TIPS
 Warming up is necessary before any operation to the balance.
 In TARE mode, the value of the tare cannot exceed the maximum capacity
of the balance
 Calibration is necessary to ensure a reliable weighing.
 Switch off the balance when it is not used.
 It is suggested to turn the round platter clockwisely before take it off the balance

Maintenance ----- Trouble shooting and solutions

Phenomenon Possible Reason Solution


Upper Line - - - - Over Load Re-calibrate the Balance
The object is not properly loaded to
Under Line_ _ _ _ Re-calibrate the Balance
the balance
Too frequently turn on and off the Turn off the balance, resume it after 3
Err-1
balance seconds
Err-2 The balance is not stablised Wait for a few seconds for stabilization