The document outlines various Intelligent Device Protocol (IDP) addressable devices compatible with Farenhyt fire alarm control panels, including detectors, modules, and accessories. It details specific devices such as photoelectric smoke detectors, thermal detectors, and modules for interfacing with conventional smoke detectors. The document emphasizes the capabilities and applications of these devices, along with installation considerations and support information.

Uploaded by

Amzad Hussain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views2 pages

HBT Fire IDP Devices

The document outlines various Intelligent Device Protocol (IDP) addressable devices compatible with Farenhyt fire alarm control panels, including detectors, modules, and accessories. It details specific devices such as photoelectric smoke detectors, thermal detectors, and modules for interfacing with conventional smoke detectors. The document emphasizes the capabilities and applications of these devices, along with installation considerations and support information.

Uploaded by

Amzad Hussain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Addressable Devices with Intelligent IDP-Heat-ROR

Device Protocol (IDP)


A fixed temperature and rate-of-rise thermal detector that uses
a thermistor sensing circuit to produce 135ºF (57ºC) thermal
Intelligent Device Protocol (IDP) devices are intelligent protection. Rate-of-rise detection occurs at 15ºF per minute
addressable devices for use with the following Farenhyt (9ºC per minute).
addressable fire alarm control panels (FACPs): IFP-2000/ECS,
IDP-Beam
IFP-1000/ECS, IFP-100/ECS, and IFP-50. IDP detectors,
A beam smoke detector that is
modules, and accessories communicate to the FACP over the
uniquely suited for protecting open
signaling line circuit loop (SLC loop) using a two-wire
areas with high ceilings where
connection. Shielded or twisted wire is not required. Up to 99
other methods of smoke detection
addressable IDP detectors and 99 IDP modules can
are difficult to install and maintain.
communicate with the IFP-50, IFP-100/ECS, and IFP-
1000/ECS FACP on a single loop. The IFP-2000/ECS can IDP-Beam-T
have up to 159 IDP detectors and 159 IDP modules on a A beam smoke detector that
single SLC loop. Any combination of addressable IDP devices includes an integrated sensitivity
IDP-Beam
and IDP modules can be used on a single SLC loop. test feature. The IDP-Beam-T is
The assortment of IDP detectors, modules, and accessories uniquely suited for protecting open areas with high ceilings
that are compatible with Farenhyt addressable FACPs are where other methods of smoke detection are difficult to install
described below. For detailed information on IDP devices, see and maintain.
the device specification sheet.
DNR/DNRW
The DNR Intelligent non-relay
Detectors photoelectric duct smoke detector
IDP-Photo housing and DNRW watertight non-
A plug-in photoelectric smoke relay photoelectric duct smoke
detector. IDP-Photo offers a detector housing (head not included)
unique optical sensing chamber are for use in air handling systems DNR
that is engineered to sense that have air velocities of 100 to 4000 ft/minute.
smoke produced by a wide range
IDP-PhotoR
of combustion sources.
Remote test capable head replacement for DNR/DNRW that
IDP-Photo (Base Not Included) has a date code of 0013 or newer.
IDP-Photo-T
A plug-in photoelectric smoke detector with thermal. IDP-Acclimate
IDP-Photo-T offers a unique optical sensing chamber that is Incorporates both thermal and photoelectric technologies that
engineered to sense smoke produced by a wide range of interact to maximize detection. The IDP-Acclimate has an on-
combustion sources. Dual electronic thermistors add 135ºF board microprocessor with advanced software that focuses on
(57ºC) thermal technology to maximize detection. rejecting nuisance alarms.
IDP-Ion IDP-FIRE-CO
A plug-in ionization smoke detector. IDP-Ion incorporates a The IDP-FIRE-CO is a plug-in, addressable device that
unique single source, dual chamber design to respond quickly provides both fire and carbon
to a broad range of fires. monoxide (CO) detection. The IDP-
IDP-Heat FIRE-CO should be used in
conjunction with the B200S
A fixed temperature thermal
intelligent sounder base.
detector that uses a thermistor
sensing circuit to produce
135ºF (57ºC) fixed thermal
detection. IDP-FIRE-CO
With B200S
IDP-Heat-HT
(Base Not included)
A variable high temperature IDP-Heat (Base Not Included)
detector that provides high
temperature detection at 135ºF
– 190ºF (57ºC – 88ºC).

P/N 350361 Rev G


Copyright © 2015 Honeywell International Inc.
Modules
IDP-Monitor IDP-Zone
A monitor module that acts as an A two-wire interface module that allows an FACP to interface
interface to contact devices, such as with and monitor two-wire conventional smoke detectors. This
waterflow switches and pull stations. means you can retrofit an existing building and use existing
The IDP-Monitor supports Class B conventional devices. The IDP-Zone supports Style B and Style
supervised or Class A supervised D wiring.
wiring.
IDP-Monitor IDP-Zone-6
IDP-Minimon A two-wire interface module that has six integrated modules
A compact and light weight monitor module that acts as an and allows an FACP to interface with and monitor two-wire
interface to contact devices, such as waterflow switches and conventional smoke detectors. This means you can retrofit an
pull stations. The IDP-Minimon supports Class B supervised existing building and use existing conventional devices. The
wiring. IDP-Zone-6 supports Class B and Class A wiring.
IDP-Monitor-2 IDP-ISO
A monitor module with two initiating circuits that acts as an A line isolator module that acts as an automatic switch that
interface to contact devices, such as waterflow switches and opens when the line voltage on the SLC loop
pull stations. Because the IDP-Monitor-2 is capable of drops below four volts. Isolator modules are
monitoring two separate Class B circuits, it is ideal for spaced between groups of sensors or
waterflow tamper switch and flow switch monitoring. modules in a loop to protect the rest of the
loop. If a short occurs between any two
IDP-Monitor-10
isolators, then both isolators immediately
A 10 point monitor module that acts as an interface to contact
switch to an open circuit state and isolate the IDP-ISO
devices, such as waterflow switches and pull stations.
devices between them.
Conventional 4-wire smoke detectors can be monitored for
alarm and trouble conditions. The IDP-Monitor-10 supports ten Accessories
Class B or five Class A supervised contact inputs.
IDP-Pull-SA/IDP-Pull-DA
IDP-Relay The IDP-Pull-SA is a single action pull station requiring only
A relay module that allows an FACP to switch discrete contacts one motion to activate the station. The IDP-Pull-DA is a dual
by code command. The relay contains two isolated sets of action pull station requiring two motions to active the station.
Form C contacts, which operate as a DPDT switch.
B210LP
IDP-Relay-6 A 6” mounting base with built-in remote annunciator
A relay module that has six Form C relays. The IDP-Relay-6 connections.
allows an FACP to switch discrete contacts by code command
and can be used by virtually any normally open or normally B200SR
closed application. The B200SR is designed for new and existing dwelling unit
applications. It offers maximum flexibility in installation,
IDP-Relaymon-2 configuration, and operation to meet or exceed UL 268 and UL
The IDP-Relaymon-2 combines two relay outputs and two 464 requirements.
monitor inputs into one module device. The module is capable
of Class B supervised wiring to the monitored devices. It also B200S
contains Form C relay contacts allowing the panel to switch the The sounder base “listens in” to the communication between
contacts on command. the attached sensor head and the fire alarm control panel
(FACP) to adopt the same address as the detector, but as a
IDP-Control unique device type on the loop. The B200S has support for CO
A notification module that lets you add notification circuits detection using the IDP-FIRE-CO.
wherever they are needed on an FACP SLC loop. The IDP-
Control provides supervised monitoring of wiring to load B224RB
devices such as bells, horns, and strobes. The IDP-Control A 6” mounting base with a built-in Form C relay contact. Lets
supports Class B and Class A wiring. you control a wide variety of normally open and normally
closed applications. The B224RB supports Class B and Class
IDP-Control-6 A wiring.
A notification module that has six
integrated modules for maximum B224BI
flexibility, allowing you to add A 6” mounting base with a built-in isolator for IDP-series
notification circuits wherever they are detectors. The B224BI prevents an entire communication loop
needed on an FACP SLC loop. from being disabled when a short circuit occurs by isolating
any part of a loop that has a short from the rest of the loop.
IDP-Control-6
Restores the entire loop when the cause of the short circuit is
corrected. Supports Class B and Class A wiring.

This document is not intended to be used for installation purposes. We try to keep our product information
up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All
specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville
Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118.
For Technical Support, Please call 800-446-6444. www.farenhyt.com

You might also like