0% found this document useful (0 votes)
37 views3 pages

Systemair Freshman Series

The Freshman Series Air Handling Units are flexible, non-packaged units designed for quiet operation in classrooms, adhering to sound performance standards. They offer various HVAC options, high efficiency features, and easy maintenance, making them suitable for diverse applications. The units are backed by sound testing certifications and provide a range of airflow and installation configurations.

Uploaded by

markrabinovich94
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views3 pages

Systemair Freshman Series

The Freshman Series Air Handling Units are flexible, non-packaged units designed for quiet operation in classrooms, adhering to sound performance standards. They offer various HVAC options, high efficiency features, and easy maintenance, making them suitable for diverse applications. The units are backed by sound testing certifications and provide a range of airflow and installation configurations.

Uploaded by

markrabinovich94
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Freshman Series Item #: #G1112 Operating Mode: Cabinet B

Freshman Air Handling Units


The Freshman series classroom units are flexible non-packaged units (no
compressor) that allow for greater design options and cabinet choices, and
that’s just the beginning.
Using a hat trick of sound guidelines and standards to give teachers and
students the absolute quietest units in North America.
Our Intelligently Quiet (IQ) design is backed by:
AMCA Standard 300-08 – Our sound laboratory is an AMCA-accredited
reverberant room. Reverberant room method for sound testing in
accordance with AMCA Standard.
ANSI/ASA S12.60 – Sound guidelines and requirements for schools –
designing a classroom with reliable data
AHRI 260 – tested in accordance with AHRI 260 – sound rating of
ducted air moving in conditioned equipment

Our Freshman IQ units are the only classroom unit that bears the AMCA label
for sound, and adhere to the above three standards and guidelines which
means you get the quietest unit ventilator for your classroom needs.
Find more details in our online catalogue

Unmatched sound performance Flexible Applications


With available Sound Power Data from an accredited reverberant HVAC performance suitable for classrooms, office spaces, gyms,
Laboratory, NC 30 classrooms are a reality. workshops and meeting rooms.

High Efficiency Unit Many heating & cooling options


Energy recovery wheel, EC Fans, COP, EER, VRF and Economizer VRF, Hot Water, Steam, Electric, High Efficiency Gas with or without
efficiency options Chilled Water, Split DX Heat & Cooling Choices

Easy service Building management system (BMS)


All components are designed to facilitate maintenance, which ensures Factory Standalone or BACnet controls.
a long reliable operation.

Certifications

Green Ventilation

Item name: Freshman Series | Product link: https://shop.systemair.com/en-US/productPermalink?p=142983 | Item #: G1112 | Variant: Cabinet B | Document type: Product card
| Created on: 2024-03-16 | Generated by: Systemair Online Catalogue | Language: English
Page 1 of 3
Freshman Series Item #: #G1112 Operating Mode: Cabinet B

Technical parameters
Unit

Air flow 700 to 2,200 cfm

Supply Location Left; Right; Face; Top

Return Location Front

Exchanger

Heat exchanger Sensible and Enthalpy wheels and cores

Others

Fan control VAV, pressure control

Installation type Vertical

Dimensions and weights

Weight 430 kg

Sound data

Sound options IQ (Intelligently Quiet); SP (Sound package)

Dimensions

Item name: Freshman Series | Product link: https://shop.systemair.com/en-US/productPermalink?p=142983 | Item #: G1112 | Variant: Cabinet B | Document type: Product card
| Created on: 2024-03-16 | Generated by: Systemair Online Catalogue | Language: English
Page 2 of 3
Freshman Series Item #: #G1112 Operating Mode: Cabinet B

Documents
Changeair High Efficiency Gas
Changeair LG VRF
Changeair VRF Daikin VRV
E1717 Changeair Series VUV IQ
E1983 Changeair Mitsubishi Sell Sheet EN
E2005 Changeair Samsung Sell Sheet EN
E2194 Changeair Mitsubishi Sales Sheet EN
Freshman Dehumidification Owners Manual
Freshman Series Owner Manual EN
Manuel D'installation Série Freshman
Freshman Datasheet EN.pdf
Freshman Datasheet FR.pdf
Beacon HS Case Study Changeair
Evansville North HS_Case Study
MadisonHS Case Study
PDSB McHugh_Case Study
Stamford Collegiate Secondary School_sm
Changeair Freshman CSI Specification Text
Changeair Freshman IQ CSI Specification Text

Item name: Freshman Series | Product link: https://shop.systemair.com/en-US/productPermalink?p=142983 | Item #: G1112 | Variant: Cabinet B | Document type: Product card
| Created on: 2024-03-16 | Generated by: Systemair Online Catalogue | Language: English
Page 3 of 3

You might also like