The AS511 Communication Driver enables serial communication between the Studio system and Siemens S5 devices using the AS511 protocol. The document outlines the necessary specifications, configuration steps, and troubleshooting tips for effectively using the driver. It includes sections on driver selection, device configuration, and execution procedures, along with a revision history for reference.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views17 pages

AS511

The AS511 Communication Driver enables serial communication between the Studio system and Siemens S5 devices using the AS511 protocol. The document outlines the necessary specifications, configuration steps, and troubleshooting tips for effectively using the driver. It includes sections on driver selection, device configuration, and execution procedures, along with a revision history for reference.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

AS511 – Driver Version 11.

05
Doc. Revision G– March 10, 2008

AS511 Communication Driver


Driver for Serial Communication with
Siemens S5 Devices Using the AS511 Protocol

Contents
INTRODUCTION ........................................................................................................................................................2

GENERAL INFORMATION ........................................................................................................................................3


DEVICE SPECIFICATIONS .........................................................................................................................................3
NETWORK SPECIFICATIONS.....................................................................................................................................3
DRIVER CHARACTERISTICS .....................................................................................................................................3
CONFORMANCE TESTING ........................................................................................................................................4
SELECTING THE DRIVER ........................................................................................................................................5

CONFIGURING THE DEVICE ...................................................................................................................................6

CONFIGURING THE DRIVER ...................................................................................................................................6


CONFIGURING THE COMMUNICATION SETTINGS .......................................................................................................6
CONFIGURING THE DRIVER WORKSHEETS ...............................................................................................................8
EXECUTING THE DRIVER ..................................................................................................................................... 13

TROUBLESHOOTING ............................................................................................................................................ 14

REVISION HISTORY............................................................................................................................................... 17

Page 1/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Introduction
The AS511 driver enables Serial communication between the Studio system and Siemens devices using the
AS511 protocol, according to the specifications discussed in this document.

This document will help you to select, configure and execute the AS511 driver, and it is organized as follows:

 Introduction: This section, which provides an overview of the document.

 General Information: Identifies all of the hardware and software components required to implement
communication between the Studio system and the target device.

 Selecting the Driver: Explains how to select the AS511 driver in the Studio system.

 Configuring the Driver: Explains how to configure the AS511 driver in the Studio system, including how to
associate database tags with device registers.

 Executing the Driver: Explains how to execute the AS511 driver during application runtime.

 Troubleshooting: Lists the most common errors for this driver, their probable causes, and basic procedures
to resolve them.

 Revision History: Provides a log of all changes made to the driver and this documentation.

 Notes:
 This document assumes that you have read the “Development Environment” chapter in Studio’s Technical
Reference Manual.
 This document also assumes that you are familiar with the Microsoft Windows NT/2000/XP environment. If
you are not familiar with Windows, then we suggest using the Help feature (available from the Windows
desktop Start menu) as you work through this guide.

Page 2/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

General Information
This chapter identifies all of the hardware and software components required to implement serial communication
between the AS511 driver in Studio and a Siemens devices

The information is organized into the following sections:


 Device Specifications
 Network Specifications
 Driver Characteristics
 Conformance Testing

Device Specifications
To establish communication, your target device must meet the following specifications:
 Manufacturer: Siemens
 Compatible Equipment: Siemens S5 Series CPU 943/944/945
 Programmer Software: Step 5
For a description of the device(s) used to test driver conformance, see “Conformance Testing”.

Network Specifications
To establish communication, your device network must meet the following specifications:
 Device Communication Port: PG port
 Physical Protocol: RS232
 Logic Protocol: Siemens AS511
 Device Runtime Software: None
 Specific PC Board: None
 Adapters/Converters: None
 Cable Wiring: Cable must be compatible with Siemens S5 Series (e.g., PC / RS232 Siemens Converter
6ES5 734-1BD20).

Driver Characteristics
The AS511 driver package consists of the following files, which are automatically installed in the \DRV
subdirectory of Studio:
 AS511.INI: Internal driver file. You must not modify this file.
 AS511.MSG: Internal driver file containing error messages for each error code. You must not modify this
file.
 AS511.PDF: This document, which provides detailed information about the AS511 driver.
 AS511.DLL: Compiled driver.

 Note:
You must use Adobe Acrobat® Reader™ to view the AS511.PDF document. You can install Acrobat Reader
from the Studio installation CD, or you can download it from Adobe’s Web site.

Page 3/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

You can use the AS511 driver on the following operating systems:
 Windows NT/2000/XP
 Windows CE
For a description of the operating systems used to test driver conformance, see “Conformance Testing” below.
The AS511 driver supports the following registers:

Register Type Length Write Read Bit Byte Word


E or I (Inputs) 1 Byte     
A or Q (Outputs) 1 Byte     
M or F (Flags) 2 Bytes     
DB (Data Blocks) 2 Bytes     
T (Timer) 2 Bytes     
C or Z (Counter) 2 Bytes     

Conformance Testing
The following hardware/software was used for conformance testing:
 Equipment: PLC S5 115U CPU944R
 Driver Configuration:
– Baud Rate: 9600
– Protocol: AS511
– Data Bits: 8
– Stop Bits: 1
– Parity: Even
– COM Port: COM1
 Cable: PC / RS232 Siemens Converter 6ES5 734-1BD20

Driver Studio Operating System Operating System


Equipment
Version Version (development) (target)
Windows XP SP2
11.05 6.1 + SP1 Windows XP SP2 PLC S5 115U CPU944R
Windows CE v5.00

Page 4/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Selecting the Driver


When you install Studio, all of the communication drivers are automatically installed in the \DRV subdirectory but
they remain dormant until manually selected for specific applications. To select the AS511 driver for your Studio
application:

1. From the main menu bar, select Insert Driver to open the Communication Drivers dialog.

2. Select the AS511 driver from the Available Drivers list, and then click the Select button.

Communication Drivers Dialog

3. When the AS511 driver is displayed in the Selected Drivers list, click the OK button to close the dialog. The
driver is added to the Drivers folder, in the Comm tab of the Workspace.

 Note:
It is not necessary to install any other software on your computer to enable communication between Studio
and your target device. However, this communication can only be used by the Studio application; it cannot
be used to download control logic to the device. To download control logic to a Siemens S5 Series device,
you must also install the Siemens programming software (e.g., Step 5). For more information, please
consult the documentation provided by the device manufacturer.

 Attention:
For safety reasons, you must take special precautions when installing any physical hardware. Please
consult the manufacturer’s documentation for specific instructions.

Page 5/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Configuring the Device


The Siemens Step 5 Programmable Controller Manual indicates the following serial communication settings:
 Baud Rate: 9600
 Data bits: 8
 Stop bits: 1
 Parity: Even
 Protocol: AS511
 Status: Run

Configuring the Driver


Once you have selected the AS511 driver in Studio, you must properly configure it to communicate with your
target device. First, you must set the driver’s communication settings to match the parameters set on the device.
Then, you must build driver worksheets to associate database tags in your Studio application with the appropriate
addresses (registers) on the device.

Configuring the Communication Settings


The communication settings are described in detail in the “Communication” chapter of the Studio Technical
Reference Manual, and the same general procedures are used for all drivers. Please review those procedures
before continuing.

For the purposes of this document, only AS511 driver-specific settings and procedures will be discussed here. To
configure the communication settings for the AS511 driver:

1. In the Workspace pane, select the Comm tab and then expand the Drivers folder. The AS511 driver is
listed here as a subfolder.

2. Right-click on the AS511 subfolder and then select the Settings option from the pop-up menu. The AS511:
Communication Parameters dialog is displayed:

Select Settings from the Pop-Up Menu AS511: Communication Parameters Dialog

3. Verify the Serial Port settings, and change them if necessary.

Page 6/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

4. Configure the additional driver-specific settings, as described in the following table:

Setting Default Value Valid Values Description


Order of words 1 (LH) 0 (HL) or 1 (LH) This setting applies only to Word writing and it
determines the order in which Words (bytes) are
written, from LOW to HIGH or from HIGH to LOW.
Addressing (Byte or Word) BYTE BYTE or WORD Sets the type of register addressing, Byte or Word. For
example, given a Header value of F:0, Byte
addressing would address registers from FY0 and
Word addressing would address registers from FW0.
NOTE: If you intend to use Data Blocks, then Word
addressing is recommended.
Order of bit LH LH or HL This setting applies only to Bit writing and it determines
the order in which Bits are written, from LOW to HIGH
or from HIGH to LOW. For example, given Word
addressing and a Header value of F:0, LH would
write FY0 FY1 and HL would write FY1 FY0.
NOTE: Bit reading is always determined by the target
device, and on the 115U, it is always HL.

5. If you are using a Data Communication Equipment (DCE) converter (e.g., 232/485) between your PC and
your target device, then you must also adjust the Control RTS (Request to Send) setting to account for the
converter. In the Communication Settings dialog, click the Advanced button to open the Advanced Settings dialog:

Advanced Settings Dialog

When the dialog is displayed, configure the Control RTS setting using the following information:

Setting Default Values Description


Control RTS no no Do not set the RTS (Request to Send) handshake signal. IMPORTANT: If you
are using Windows 95/98 or Windows CE with the correct RS232/RS485
adapter (i.e. without RTS control), then you must select this option.
yes Set the RTS (Request to Send) handshake signal before communication.
IMPORTANT: If you are using Windows NT and the Cutler-Hammer
RS232/RS485 adapter, then you must select this option.
yes+echo Set the RTS (Request to Send) handshake signal before communication, and
echo the signal received from the target device.

Page 7/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

 Attention:
If you incorrectly configure the Control RTS setting, then runtime communication will fail and the driver
will generate a –15 error. See “Troubleshooting” for more information.

You do not need to change any other advanced settings at this time. You can consult the Studio
Technical Reference Manual later for more information about configuring these settings.
6. Click OK to close the Advanced Settings dialog, and then click OK to close the Communication Settings dialog.

Configuring the Driver Worksheets


A selected driver includes one or more driver worksheets, which are used to associate database tags in Studio
with operands on the target device. Each worksheet is triggered by specific application behavior, so that the tags /
operands defined on that worksheet are scanned only when necessary – that is, only when the application is
doing something that requires reading from or writing to those specific tags / operands. Doing this optimizes
communication and improves system performance.

The configuration of these worksheets is described in detail in the “Communication” chapter of the Studio
Technical Reference Manual, and the same general procedures are used for all drivers. Please review those
procedures before continuing.

 Note:
We recommend configuring operands on the device in sequential blocks in order to maximize performance.

To insert a new driver worksheet:


1. In the Comm tab, open the Drivers folder and locate the AS511 subfolder.

2. Right-click on the AS511 subfolder, and then select Insert from the pop-up menu:

Inserting a New Worksheet

Page 8/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

A new AS511 driver worksheet is inserted into the AS511 subfolder, and the worksheet is opened for
configuration:

Header

Body

AS511 Driver Worksheet

 Note:
Worksheets are numbered in order of creation, so the first worksheet is AS511001.drv.

Most of the fields on this worksheet are standard for all drivers; see the “Communication” chapter of the
Technical Reference Manual for more information on configuring these fields. However, the Station,
Header, and Address fields use syntax that is specific to the AS511 driver.

3. Configure the Station and Header fields as follows:

 Station field: Not used for Serial communication; you can configure the necessary settings in the
Communication Parameters dialog described above.

 Header field: Specify the address of the first register of a block of registers on the target device. The
addresses declared in the Body of the worksheet are simply offsets of this Header address. When
Read/Write operations are executed for the entire worksheet (see Read Trigger and Write Trigger
above), it scans the entire block of registers from the first address to the last.

For Flags, Inputs and Outputs, use the following syntax:


<Register Type>[Data Format]:<Address Reference>
Examples — MW:1

For Data Blocks, use the following syntax:


<Register Type><Block Number>:<Address Reference>
Example — DB2:1

Page 9/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Where:

– <Register Type> : Siemens register type. Valid values are E or I (Input), A or Q (Output), M
or F (Flag), DB (Data Block), T (Timer) and C or Z (Counter).

– [Data Format] (optional): Format of the data being read or written. Valid values are B (Byte)
and W (Word). This parameter is optional and if it is omitted, then the value configured in
Addressing (Byte or Word) is used by default. (See “Configuring the Communication Settings”
above.)

 Note:
The [Data Format] parameter does not apply to DB (Data Block), T (Timer), C or Z
(Counter) registers; These registers are always formatted as Words.

– <Block Number> : Number of the data block.

– <Address Reference> : The initial address (reference) of the block of registers configured on
this worksheet. This value always refers to the Byte address number; see following table.

Header Address Siemens Address

Byte Address Number Byte Address Number Word Address Number


Byte 0 Byte 0
W0
Byte 1 Byte 1
W1
Byte 2 Byte 2
W2
Byte 3 Byte 3
W3
Byte 4 Byte 4
W4
Byte 5 Byte 5
W5
Byte 6 Byte 6
W6
Byte 7 Byte 7
W7
Byte 8 Byte 8
W8
Byte 9 Byte 9
W9
Byte 10 Byte 10
W10
Byte 11 Byte 11

Page 10/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

For descriptions of valid values for the Header field, see the following table:

Type Sample of syntax Valid range of initial Address Comment


Input I:0, E:0, IB:0, IW:0, Varies according to the Physical Inputs.
EB:0 or EW:0 equipment. (E.g. I0 to I127 for We can read its status from words or from bytes
the 115U 944 PLC) and we can, but should not, write on them.
Output Q:0, A:0, QB:0, Varies according to the Physical Outputs.
QW:0, AB:0 or AW:0 equipment. (E.g. Q0 to Q127 We can read its status from words or from bytes
for the 115U 944 PLC) and we can, but should not, write on them.
Flag F:0, M:0, FY:0, FW:0, Varies according to the Internal Auxiliary Flag. Can be read or written by
MY:0 or MW:0 equipment. (E.g. F0 to F255 for words, bytes or bits. Just take care about the
the 115U 944 PLC) Order of bit writing field at the Communication
Parameters
Data Block DB1:0 Varies according to the We can read and write the whole data word from
equipment. (E.g. DB0:0 to a Data Block and we can also read and write its
DB255:255 for the 115U 944 block, always taking care with the “Order of bit
PLC) writing” on the Communication Parameters
window. In the Header, always type the DB
number, followed by the initial data word number
after the colon.
Timer T:0 Varies according to the We can read and write the whole data word,
equipment. always taking care with the “Order of bit writing”
on the Communication Parameters window.
Counter C:0 or Z:0 Varies according to the We can read and write the whole data word,
equipment. always taking care with the “Order of bit writing”
on the Communication Parameters window.

4. For each table row (i.e., each tag/register association), configure the Address field using the following
syntax…
<Address Offset>.[Bit]
Example — 10, 0.7

Where:

– <Address Offset> : Value added to the <Address Reference> parameter (configured in the
Header field above) to produce complete register address.

– [Bit] (optional): The bit number of the address. Valid values are 0 to 15 for Word-formatted
addresses and Data Blocks, and 0 to 7 for Byte-formatted Inputs, Outputs and Flags.

Page 11/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

For examples of how device registers are specified using Header and Address, see the following table:

Address on the PLC Header Field Address Field


IW0 I:0 0
IW10 I:0 10
IW10 I:10 0
I0.0 I:0 0.0
I0.7 IB:0 0.7
I1.0 IW:1 0.0
I1.5 I:1 0.5
QW0 Q:0 0
QW10 QW:0 10
QW10 Q:10 0
Q0.0 QB:0 0.0
Q0.7 QW:0 0.7
Q1.0 Q:1 0.0
Q1.5 Q:1 0.5
FW0 FW:0 0
FW10 F:0 10
FW10 F:10 0
F0.0 F:0 0.0
F0.7 FW:0 0.7
F1.0 FB:1 0.0
F1.5 F:1 0.5
DB100, DW 0 DB100:0 0
DB100, DW 100 DB100:0 100
DB100, DW 100 DB100:100 0
T10 T:0 10
T10 T:10 0
C5 C:5 0
C5 C:0 5

For more information about device registers and addressing, please consult the manufacturer’s documentation.

 Attention:
You must not configure a range of addresses greater than the maximum block size (data buffer length)
supported by each device within the same worksheet. The maximum data buffer length for this driver is 255
bytes per driver worksheet.

Page 12/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Executing the Driver


By default, Studio will automatically execute your selected communication driver(s) during application runtime.
However, you may verify your application’s runtime execution settings by checking the Project Status dialog.

To verify that the the communication driver(s) will execute correctly:

1. From the main menu bar, select Project → Status. The Project Status dialog displays:

Project Status Dialog

2. Verify that the Driver Runtime task is set to Automatic.

 If the setting is correct, then proceed to step 3 below.

 If the Driver Runtime task is set to Manual, then select the task and click the Startup button to toggle the
task’s Startup mode to Automatic.

3. Click OK to close the Project Status dialog.

4. Start the application to run the driver.

Page 13/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Troubleshooting
If the AS511 driver fails to communicate with the target device, then the database tag(s) that you configured for
the Read Status or Write Status fields of the Main Driver Sheet will receive an error code. Use this error code and the
following table to identify what kind of failure occurred.

Error Code Description Possible Causes Procedure to Solve

0 OK Communication without problems None.


1 Station number must Wrong station number typed Check on the driver configuration’s worksheet
always be 0 that is getting this error if the configured
station is different then. If so, correct it.
2 Only I, Q, F, DB1 – An invalid Header has been typed or Type a valid Header either on the header field
DB255 as allowed entries the tag that is inside this field has an or on the tag value. A lot of different valid
invalid configuration. headers are shown on the section IV.2
3 Only decimal values and An invalid Address has been typed. Sometimes people type bit addressing with
bits allowed letters (0 to 9 and then A to F). This driver
requires 0 to 15 or 0 to 7 as bit addressing.
Take a look at the driver worksheet and
correct it.
4 Block size exceeded Block size is greater then 255 The highest allowed offset is 255. Reconfigure
your Driver worksheet.
5 Protocol error  Fail in the protocol There is something wrong with the
 Timeout waiting start a message communication. Check the communication
 Cable not connected parameters, the PLC settings, cable, etc…
 PLC without a program Sometimes the PLC does not send a complete
 Non-existent address in the PLC answer when the message is too big.
 Incomplete answer sent by the PLC
6 Checksum error Fail in the protocol There is something wrong with the
communication. Check the communication
parameters and the PLC settings.
7 Non-existent module Wrong header, station number, etc… Check the Header and the values. It must be
one of the valid.
8 Bit writing forbidden It is not allowed to write bits. Maybe we are trying to write a bit where it is
not possible.
9 Write blocks only in We are trying to write with the Write Correct the worksheet without letting any
continuous areas! trigger and the worksheet has spaces space between the addresses. To write group
between the addresses all the addresses areas must be continuous.
10 Wrong Interface to the Problems with the serial ports If you are using the transit mode with a
Transfer Mode number different then 0, so you are using
another COM port. To get this error you must
have declared a wrong COM port on the “
Transit mode from COMx” Communication
Parameters field.

Page 14/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

AS511/S5-945 - Driver Configuration

1. Communication Parameters

On communication parameters, use:


Baud: 9600
Bits: 8
Stop: 1
Parity: Even

Modification in the AS511/S5-945 Drivers's Configuration (Version 9.21):


Addressing(Byte or Word): Addressing type of the protocol. Default: Byte
Order of bit writing(LH or HL): Order of bit writing (Low and High, or , High and Low). Default: LH

2. Read and Write groups

Station: not used


Header valid entries:
M Flags
T Timer
Z Counter
E Inputs
A Outputs
DBxx Data block xx
Address:
Offset
Offset.Bit //0..15 or 0..7 according to type

3. LogWin

Attention: when using this driver do not enable the LOG/SERIAL COMMUNICATION on
LogWin, because it can generate communications errors with this drivers.

Modification in the AS511/S5-945 Drivers's Configuration


(Version 8.00):

1. Offset Address

Now it is possible to define an offset address in the Header of the Driver's Configuration.
This new feature is very usefull in cases when it is necessary to do a shift in the address range in
the PLC or if the user needs to realize an on-line driver configuration.
This modification was thought, in principle, for applications that need an on-line change of the
offset-address.

In the former configuration, the user had to define in the HEADER field simply the data-range
and the number of the data-block (DB), if the case.
Ex: Let's define the configuration-table for DB number 5.
Header : DB5
Tag Name : var[0]

Page 15/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

 Tip:
You can monitor communication status by establishing an event log in Studio’s Output window (LogWin
module). To establish a log for Field Read Commands, Field Write Commands and Serial Communication, right-click
in the Output window and select the desired options from the pop-up menu.
You can also use the LogWin module (Tools  LogWin) to establish an event log on a remote unit that runs
Windows CE. The log is saved on the unit in the celog.txt file, which can be downloaded later.

If you are unable to establish communication between Studio and the target device, then try instead to establish
communication using the device’s own programming software (e.g., Step 5). Quite often, communication is
interrupted by a hardware or cable problem or by a device configuration error. If you can successfully
communicate using the programming software, then recheck the driver’s communication settings in Studio.

If you must contact us for technical support, please have the following information available:
 Operating System (type and version): To find this information, select Tools → System Information.
 Project Information: To find this information, select Project → Status.
 Driver Version and Communication Log: Displays in the Studio Output window when the driver is running.
 Device Model and Boards: Consult the hardware manufacturer’s documentation for this information.

Page 16/17
AS511 – Driver Version 11.05
Doc. Revision G– March 10, 2008

Revision History
Revision Version Author Date Description of Changes
 First driver version
A 11.01 Roberto V. Junior 30-Jul-1999
 Driver available for Windows CE
B 11.02 Roberto V. Junior 19-Apr-2000 Implemented consistence tests when communicating with DBs.
C 11.03 José L. Teodoro 20-Jul-2001 Fixed problems with Windows CE.
D 11.04 José L. Teodoro 14-Nov-2001 Inserted the word order option.
E 11.05 Rafael R. Fernandes 22-Sep-2006 UDrvOpen Modified for SCPortOpen not to be called twice.
F 11.05 Michael D. Hayden 08-Dec-2006 Edited for language and usability.
G 11.05 Eric Vigiani 10-Mar-2008 Added information’s about Timer and Counter.