0% found this document useful (0 votes)
40 views19 pages

Dm1a 1

This document contains technical information related to Schneider Electric's project DM1-A for Meiko, including equipment specifications and layout diagrams. It emphasizes that the information is proprietary and cannot be shared without consent, and outlines the order number and revision details. The document consists of 19 pages detailing various components such as circuit breakers, current transformers, and control circuits.

Uploaded by

iannurhadianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views19 pages

Dm1a 1

This document contains technical information related to Schneider Electric's project DM1-A for Meiko, including equipment specifications and layout diagrams. It emphasizes that the information is proprietary and cannot be shared without consent, and outlines the order number and revision details. The document consists of 19 pages detailing various components such as circuit breakers, current transformers, and control circuits.

Uploaded by

iannurhadianto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

1 2 3 4 5 6 7 8 9 10

Schneider Electric
A

EJIP PLOT 4B1-4B2 CIKARANG SELATAN


17550 BEKASI

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
Phone. +62 21 8970203
Fax +62 21 8970209
B

Company / Customer -
Project name DM1-A FOR MEIKO
Order Number / WBS Number C2030-4050932
C

Client -

Manufacturer (company) Schneider Electric


Switchboard Name
Type of equipment SM6
Country VIETNAM
D
E

Drawn by WDD Checked by NUG Approved by RZK


F

Schneider Electric Project Name Page description Order Number / WBS Number Page 1
B 26/10/2023 Revision 1 Title page / cover sheet C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Table of contents SE_SEC_F06_002

Page N° Page description Revision Remarks


A

1 Title page / cover sheet DM1-A A B

2 Table of contents DM1-A A B

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
3 Layout component DM1-A A B

4 Circuit breaker and contacts DM1-A A B

5 Current transformers 1st secondary DM1-A A B

6 Current transformers 2nd secondary DM1-A A B


B

7 Z-Plan Relay DM1-A A B

8 Earthing Switch and contacts DM1-A A B

9 Auxiliary power supply DM1-A A B

10 Control Circuit DM1-A A B

11 Control Circuit DM1-A A B

12 Control Circuit DM1-A A B

13 Control Circuit DM1-A A B


C

14 Table of Component DM1-A A B

15 Terminal diagram DM1-A A B

16 Terminal diagram DM1-A A B

17 Terminal diagram DM1-A A B

18 Part list DM1-A A B

19 Part list DM1-A A B


D
E
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 2
B 26/10/2023 Revision 1 Table of contents C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

FRONT VIEW FRONT VIEW


(W=750) (Door & Cover removed)
A

-Q4

-Q5

-Q6
-CN

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
630 mm
-F1

1
2
3
4
5
6
7
8
B

-XB1 -XB2 -XB3 -XB4 -XB30

630 mm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

1
2
3
4
5
6
6
7
8
C

-XB31

350 mm
-X1.2

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
-1S2 -1S1 -S41 -H1 -H2
D

-F1
DISPLAY RELAY FUNCTION

F1 F2
Enclosure legend
E

Device tag Label Engraving Function button 1 Function button 2


-H1 OPEN POWER SERVICE
-H2 CLOSED
OPEN CLOSED
-S41 LOCAL-REMOTE
-F1 PROTECTION AND MEASURING RELAY I>51 I>>50

-X1.2 CURRENT TEST BLOCK Io>51N Io>>50N


-1S1 CLOSE
TRIP
-1S2 OPEN
F2
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 3
B 26/10/2023 Revision 1 Layout component C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

L1

L2

L3
A

O O

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
D/S CLOSED D/S OPEN D/S CLOSED D/S OPEN

-Q2 (SPARE) (SPARE) (SPARE) (SPARE)

D/S A B

-XB30 5 6 -XB30 6 -XB30 1 -XB30 3


=
-Q2 -Q2 -Q2 -Q2
B

Output Contact cross ref


S5:1 +4/2B S9:1 +4/2B S6:1 +4/2B S8:1 +4/2B
S5:4
S5 S5:1 4/6B S5 S9 S6 S8
S5:2
S6:4 S5:2 S5:4 S9:2 S9:4 S6:2 S6:4 S8:2 S8:4
S6 S6:1 4/7B
S6:2
-Q3 S8
S8:2

S8:4
S8:1 4/8B -XB30 7 -XB30 8 -XB30 2 -XB30 4
E/S
S9:2
S9 S9:1 4/7B
S9:4
C

CB CLOSE CB OPEN CB CLOSE CB OPEN CB CLOSE


-Q1
D

(SPARE) (SPARE) (SPARE) (SPARE) (SPARE)


CIRCUIT BREAKER C
-XB3 1 -XB3 3 -XB3 5 -XB3 7 -XB3 9

=
Output Contact cross ref -XB31 15 -XB31 17 -XB31 19 -XB31 21 -XB31 23 -XB31 8 -XB31 9 -XB31 25-XB31 26
QF 2 1 10/4E

QF 4 3 10/5E

QF 5 6 12/3C
19 21 23 25 27
QF 7 8 12/3C -Q1 -Q1 -Q1 -Q1 -Q1
+4/2D +4/2D +4/2D +4/2D +4/2D 77+ 78- 90 91
QF 11 12 11/3E
QF 20 QF 22 QF 24 QF 26 QF 28
QF 15 16
TERMINAL CB
E

QF 17 18 11/3E
Q3.1 QF 19 20 4/7E -XB31 16 -XB31 18 -XB31 20 -XB31 22 -XB31 24
8/1A
QF 21 22 4/7E

QF 23 24 4/7E

QF 25 26 4/8E -XB3 2 -XB3 4 -XB3 6 -XB3 8 -XB3 10


QF 27 28 4/8E

M B1 B2 10/2D
3~
M

YF A1 A2 10/4F

YO1 C1 C2 11/3F

L1 L2 L3
F

5/2A 5/2A 5/2A

Schneider Electric Project Name Page description Order Number / WBS Number Page 4
B 26/10/2023 Revision 1 Circuit breaker and contacts C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

4/3F 4/3F 4/4F


L1 L2 L3
A

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
=
-XB4 1 REMOVED "LINK"
IF USE
B

1P1 1S1 -XB4 2

-T1

CT'S CONNECTION
FOR METERING
+6/2B
DETAIL CT 1S2
1P2

[SPARE]
SEE SLD

1P1 1S1 -XB4 3

-T2
+6/2C
DETAIL CT 1S2
1P2
SEE SLD
C

1P1 1S1 -XB4 4

-T3
+6/2C
DETAIL CT 1S2
1P2
SEE SLD
D
E

L1 L2 L3
F

6/2A 6/2A 6/2A

Schneider Electric Project Name Page description Order Number / WBS Number Page 5
B 26/10/2023 Revision 1 Current transformers 1st secondary C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

5/2F 5/2F 5/2F


L1 L2 L3
A

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
+D1-X1.2 +D1-F1
CURRENT TEST BLOCK +7/2A
48 - 230V
1 01
B

2P1 2S1 2 02
X1:1 IL1 X1:2
-T1
+5/2B
2S2
2P2

2P1 2S1 3 03
X1:3 IL2 X1:4
-T2
+5/2C
2S2
2P2
C

2P1 2S1 4 04
X1:5 IL3 X1:6
-T3
+5/2C
2S2
2P2

X1:7 1A/5A X1:8


I0
X1:9 0.2A/1A X1:10
D
E

L1 L2 L3
F

8/2A 8/3A 8/3A

Schneider Electric Project Name Page description Order Number / WBS Number Page 6
B 26/10/2023 Revision 1 Current transformers 2nd secondary C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
A 1 2 3 4 5 6 7 8 9 10

+D1-F1
PROTECTION AND MEASURING RELAY

REL52018

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
Output Contact cross ref
X3:8
Front
P3U20-5AAA2ACAA A1 X3:7 12/5C
X3:9
X3:20
SF X3:18 12/6C
X3:19
T1 X3:17 X3:16 11/4B
PROTECTIONS
T2 X3:15 X3:14 10/4C

T3 X3:13 X3:12 12/7C


37/38/49T/46
B

T4 X3:11 X3:10 12/7C


49/46BC/48
51LR/50/51/99
50BF/50N/51N
50HS/51C/59C
59N/60/66/86
67N/68F2/79
C

+/~
9/5E / C5 X2:3

-/~
9/4E / D5 X2:4

Eth1

X4

Eth2
D

MEASUREMENTS

A Hz V
E

PE

1
-MM2
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 7
B 26/10/2023 Revision 1 Z-Plan Relay C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
B
A
F E D C B A

Rev. Date
18/10/2023
26/10/2023
1

Revision 1
First Issued
E/S
-Q3.1

Revision description
4/2E
Q3.1
2

TH110 SENSORS

Rev. Date
-B1L1-3

L1
L1
6/2F

L2
L2
6/2F

Revision description
3

L3
L3
6/2F

-H21
4

VOLTAGE INDICATION

Schneider Electric
5

Project Name

DM1-A FOR MEIKO


6

Page description
7

DM1-A
Earthing Switch and contacts
8

C2030-4050932
Customer Drawing number
Order Number / WBS Number
9

Drawing number
10

Z-4050932-30-002-1-30
Page
Total pages

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
19
8
B
A
F E D C B A

Rev. Date
INTERCONNECTION

18/10/2023
26/10/2023
FROM PREV. CUBICLE
1

Revision 1
First Issued
=

-CN
-CN
-CN
-CN

Revision description
7
5
3
1
2

220VAC (N)
220VAC (N)

220VAC (PH)
220VAC (PH)

Rev. Date
-EH1
2A
-Q4

Revision description
3

2
1

2
1

=
-XB1
D1

1
10/1F

D2

2
11/1F
4

D3

D5
7/1C

3
12/1F

10A
D4 -Q5

2
1

4
13/1F

Schneider Electric
-XB1
C1
4
3

5
10/1A

C2

C5
7/1C

6
11/1A

C3
5

Project Name
12/1A

C4

8
13/1A
10A
-Q6

M2
2
1

10/2E

DM1-A FOR MEIKO


6

M1
4
3

10/2C

Page description
7

DM1-A
Auxiliary power supply
8

C2030-4050932
Customer Drawing number
Order Number / WBS Number
9

-CN
-CN
-CN
-CN

Drawing number
8
6
4
2
10

INTERCONNECTION
Z-4050932-30-002-1-30

TO NEXT CUBICLE
Page
Total pages

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
19
9
1 2 3 4 5 6 7 8 9 10

SPRING CHARGING CLOSING FROM


MOTOR CLOSING REMOTE

9/5F / C1
A

11 13 23 33 11 21 31
+D1-S41 +D1-S41
+10/5A 12 LOCAL-REMOTE 14 24 34 12 22 32

+11/3A

+10/4A

+11/3A

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
-XB1 13 -XB1 14

13
+D1-1S1

FROM REMOTE
CLOSE 14

CLOSING
B

-XB1 15 -XB1 16

M1
C

9/6F / X3:15
+D1-F1 Programmable NC
+7/2A Inhibit Close
X3:14
T2

-XB31 1

67
9 10
INTERLOCK
FACILITY

-Q1 M
+4/2D
D

5 -XB1 11 12
-M1
6

68
-XB31 3 -XB31 5

-XB31 2
69
11
-KN 71

12
2 4 41
-Q1 -Q1 -KN
E

+4/2D +4/2D
QF 1 QF 3 44
1
9/6F / M2 -M2
2

75 76

-Q1 -KN
+4/2D
YF

70
F

-XB31 4

9/4F / D1

Schneider Electric Project Name Page description Order Number / WBS Number Page 10
B 26/10/2023 Revision 1 Control Circuit C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

OPENING FROM TRIP CIRCUIT


REMOTE OPENING TRIP SUPERVISION

9/5F / C2
A

23 21
+D1-S41 +D1-S41
+10/5A 24 +10/5A 22

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
+
-XB1 17 -XB1 18 +D1-F1 +
+7/2A
X3:3
X3:5
13 X3:17
+D1-1S2 +D1-F1 DI 1

FROM REMOTE
OPEN +7/2A DI 2
14 X3:16
OPENING T1
X3:4
X3:6
B

-
-

-XB1 19 -XB1 20
C

-XB3 15
D

-XB31 7 -XB31 13 14

11 17
-Q1 -Q1
E

+4/2D +4/2D
QF 12 QF 18

89

-Q1
+4/2D
YO1

88

-XB31
F

9/4F / D2

Schneider Electric Project Name Page description Order Number / WBS Number Page 11
B 26/10/2023 Revision 1 Control Circuit C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

DIGITAL OUTPUT WATCHDOG DIGITAL OUTPUT DIGITAL OUTPUT


OPEN CLOSED (SPARE) (SPARE) (SPARE) (SPARE)

9/5F / C3
A

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
=
-XB3 11 -XB3 12
B

=
-XB31 10 -XB2 1 3 -XB2 4 6 -XB2 7 -XB2 9

74

6 8
-Q1 -Q1
+4/2D +4/2D
QF 5 QF 7

-XB31 12 11
C

X3:9 X3:8 X3:19 X3:20 X3:13 X3:11


+D1-F1 +D1-F1 +D1-F1 +D1-F1
+7/2A X3:7 +7/2A X3:18 +7/2A X3:12 +7/2A X3:10
A1 SF T3 T4
D

-XB3 13 -XB3 14 -XB2 2 -XB2 5 -XB2 8 -XB2 10


E

X1 X1
+D1-H1 +D1-H2
GREEN X2 RED X2
OPEN CLOSED
F

9/4F / D3

Schneider Electric Project Name Page description Order Number / WBS Number Page 12
B 26/10/2023 Revision 1 Control Circuit C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT DIGITAL INPUT
(SPARE) (SPARE) (SPARE) (SPARE) (SPARE) (SPARE) (SPARE) (SPARE)

9/5F / C4
A

-XB2 11 -XB2 12 -XB2 13 -XB2 14 -XB2 15 -XB2 16 -XB2 17 -XB2 18

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
B

-XB2 19 -XB2 20 -XB2 21 -XB2 22 -XB2 23 -XB2 24 -XB2 25 -XB2 26


C
D
E

+D1-F1
+7/2A
X4:2 X4:4 X4:6 X4:8 X4:10 X4:11 X4:13 X4:14
48 - 230V

DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 DI 9 DI 10

X4:1 X4:3 X4:5 X4:7 X4:9 X4:12


F

9/4F / D4

Schneider Electric Project Name Page description Order Number / WBS Number Page 13
B 26/10/2023 Revision 1 Control Circuit C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

NOTE:
1. SELECTION OF AUX. SUPPLY SEE DATA SPECIFICATION ON SINGLE LINE DIAGRAM PAGE 3,
2. FOR DC AUX. SUPPLY (Vdc) PILOT LAMP NO NEED ENERGY LIMITER
CLOSING COIL Type.1 OPENING COIL Type.2

DESCRIPTION SERVICE VOLTAGE REF. No. DESCRIPTION SERVICE VOLTAGE REF. No.
A

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 24 Vdc 00889705AM "Y01" 1st & "Y02" 2nd OPENING COIL 24 Vdc 887191HM

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 110 Vdc 889705AF "Y01" 1st & "Y02" 2nd OPENING COIL 48 Vdc 887191HJ

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 125 Vdc 889705AE "Y01" 1st & "Y02" 2nd OPENING COIL 110 Vdc 887191HF

30~32 Vdc "Y01" 1st & "Y02" 2nd OPENING COIL 120~125 Vdc 887191HE
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 889705AL
110~120 Vac 50/60Hz
48 Vdc "Y01" 1st & "Y02" 2nd OPENING COIL 220 Vdc 887191HC
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 889705AJ
230~240 Vac 60Hz
60 Vdc 30~32 Vdc
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 889705AH "Y01" 1st & "Y02" 2nd OPENING COIL 887191HL
220~230 Vac 50Hz 110~120 Vac 50/60Hz
B

60 Vdc
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 48 Vac 50Hz 889705AP "Y01" 1st & "Y02" 2nd OPENING COIL 887191HH
220~240 Vac 50/60Hz
"Y01" 1st & "Y02" 2nd OPENING COIL 48 Vac 50Hz 887191HP
OPENING COIL Type.1
"Y01" 1st & "Y02" 2nd OPENING COIL 120 Vac 50Hz 887191HK
DESCRIPTION SERVICE VOLTAGE REF. No.

"Y01" 1st & "Y02" 2nd OPENING COIL 24 Vdc 889705BM


PILOT LAMP
"Y01" 1st & "Y02" 2nd OPENING COIL 48 Vdc 889705BJ
DESCRIPTION SERVICE VOLTAGE REF. No.
"Y01" 1st & "Y02" 2nd OPENING COIL 110 Vdc 889705BF
PILOT LAMP, WHITE 220~240 Vac EILW240A
C

"Y01" 1st & "Y02" 2nd OPENING COIL 120~125 Vdc 889705BE
PILOT LAMP, GREEN 220~240 Vac EILG240A
"Y01" 1st & "Y02" 2nd OPENING COIL 220 Vdc 889705BC
30~32 Vdc PILOT LAMP, RED 220~240 Vac EILR240A
"Y01" 1st & "Y02" 2nd OPENING COIL 889705BL
110~120 Vac 50/60Hz
60 Vdc PILOT LAMP, YELLOW 220~240 Vac EILY240A
"Y01" 1st & "Y02" 2nd OPENING COIL 889705BH
220~230 Vac 50/60Hz
PILOT LAMP, BLUE 220~240 Vac EILB240A
"Y01" 1st & "Y02" 2nd OPENING COIL 48 Vac 50Hz 889705BP
PILOT LAMP, WHITE 110 Vdc EILW110D

SPRING CHARGING MOTOR PILOT LAMP, GREEN 110 Vdc EILG110D


D

DESCRIPTION SERVICE VOLTAGE REF. No. PILOT LAMP, RED 110 Vdc EILR110D

"M" SPRING CHARGING MOTOR 24 Vdc 886657 PILOT LAMP, YELLOW 110 Vdc EILY110D

"M" SPRING CHARGING MOTOR 48 Vdc 886658 PILOT LAMP, BLUE 110 Vdc EILB024C

"M" SPRING CHARGING MOTOR 110 Vdc/Vac 886661 PILOT LAMP, WHITE 24 Vdc/Vac EILW024C

"M" SPRING CHARGING MOTOR 220 Vdc/Vac 886662 PILOT LAMP, GREEN 24 Vdc/Vac EILG024C

CLOSING COIL Type.2 PILOT LAMP, RED 24 Vdc/Vac EILR024C


E

DESCRIPTION SERVICE VOLTAGE REF. No. PILOT LAMP, YELLOW 24 Vdc/Vac EILY024C

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 24 Vdc 887191HM PILOT LAMP, BLUE 24 Vdc/Vac EILB024C

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 110 Vdc 887191HF PILOT LAMP, WHITE 48 Vdc/Vac EILW048C

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 125 Vdc 887191HE PILOT LAMP, GREEN 48 Vdc/Vac EILG048C
30~32 Vdc
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 887191HL PILOT LAMP, RED 48 Vdc/Vac EILR048C
110~120 Vac 50Hz
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 48 Vdc 887191HJ PILOT LAMP, YELLOW 48 Vdc/Vac EILY048C
60 Vdc
"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 887191HH PILOT LAMP, BLUE 48 Vdc/Vac EIB048C
220~240 Vac 50/60Hz
F

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 48 Vac 50Hz 887191HP

"YF" CLOSING COIL; "KN" RI ANTI PUMPING RELAY 120 Vac 60Hz 887191HK

Schneider Electric Project Name Page description Order Number / WBS Number Page 14
B 26/10/2023 Revision 1 Table of Component C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Terminal diagram SEC_LEVEL1_F13_003


A

M1 M1
-CN -XB1
Saddle Jumper Saddle Jumper
Insertable Insertable Insertable Insertable

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
Target designation Jumper Jumper Target designation Placement Terminal Type Target designation Jumper Jumper Target designation Placement Terminal Type

1 -Q4:1 +9/1A ST 2,5 13 +D1-S41:14 +10/5B ST 2,5

2 +9/10A ST 2,5 14 +10/5B ST 2,5

3 +P-EH1:2 +9/1A ST 2,5 15 +D1-1S1:14 +10/5B ST 2,5


B

4 +9/10A ST 2,5 16 +M2-XB31:5 +10/5B ST 2,5

5 -Q5:3 +9/1A ST 2,5 17 +D1-S41:24 +11/3B ST 2,5

6 +9/10A ST 2,5 18 +11/3B ST 2,5

7 -Q5:1 +9/1A ST 2,5 19 +M2-XB31:7 +11/3B ST 2,5

8 +9/10A ST 2,5 20 +D1-1S2:14 +11/3B ST 2,5


C

M1 M1
-XB1 -XB2
Saddle Jumper Saddle Jumper
Insertable Insertable Insertable Insertable
Target designation Jumper Jumper Target designation Placement Terminal Type Target designation Jumper Jumper Target designation Placement Terminal Type

+M2-XB31:4 1 +9/4F ST 2,5 1 +D1-F1:X3:9 +12/5B ST 2,5

+M2-XB31:6 2 +9/4F ST 2,5 2 +D1-F1:X3:7 +12/5E ST 2,5


D

+D1-H1:X2 3 +D1-F1:X2:4 +9/4F ST 2,5 3 +D1-F1:X3:8 +12/6B ST 2,5

+D1-F1:X4:1 4 -Q5:2 +9/4F ST 2,5 4 +D1-F1:X3:19 +12/6B ST 2,5

+D1-S41:11 5 -Q5:4 +9/5F ST 2,5 5 +D1-F1:X3:18 +12/6E ST 2,5

+D1-S41:23 6 +D1-F1:X2:3 +9/5F ST 2,5 6 +D1-F1:X3:20 +12/6B ST 2,5

-XB3:11 7 +9/5F ST 2,5 7 +D1-F1:X3:13 +12/7B ST 2,5


E

-XB2:11 8 +9/5F ST 2,5 8 +D1-F1:X3:12 +12/7E ST 2,5

9 +D1-F1:X3:14 +10/4D ST 2,5 9 +D1-F1:X3:11 +12/7B ST 2,5

10 +10/4D ST 2,5 10 +D1-F1:X3:10 +12/7E ST 2,5

11 +M2-XB31:3 +10/4D ST 2,5 11 -XB1:8 +13/1A ST 2,5

12 +10/4D ST 2,5 12 +13/2A ST 2,5


F

Schneider Electric Project Name Page description Order Number / WBS Number Page 15
B 26/10/2023 Revision 1 Terminal diagram C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Terminal diagram SEC_LEVEL1_F13_003


A

M1 M1
-XB2 -XB3
Saddle Jumper Saddle Jumper
Insertable Insertable Insertable Insertable

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
Target designation Jumper Jumper Target designation Placement Terminal Type Target designation Jumper Jumper Target designation Placement Terminal Type

13 +13/3A ST 2,5 7 +M2-XB31:21 +4/8D ST 2,5

14 +13/3A ST 2,5 8 +M2-XB31:22 +4/8F ST 2,5

15 +13/4A ST 2,5 9 +M2-XB31:23 +4/8D ST 2,5


B

16 +13/5A ST 2,5 10 +M2-XB31:24 +4/8F ST 2,5

17 +13/5A ST 2,5 +M2-XB31:10 11 -XB1:7 +12/3B ST 2,5

18 +13/6A ST 2,5 12 +12/3B ST 2,5

19 +D1-F1:X4:2 +13/1C ST 2,5 +D1-H1:X1 13 +M2-XB31:12 +12/3E ST 2,5

20 +D1-F1:X4:4 +13/2C ST 2,5 +D1-H2:X1 14 +M2-XB31:11 +12/3E ST 2,5

21 +D1-F1:X4:6 +13/3C ST 2,5 +D1-F1:X3:4 15 +M2-XB31:13 +11/6D ST 2,5


C

22 +D1-F1:X4:8 +13/3C ST 2,5

23 +D1-F1:X4:10 +13/4C ST 2,5


M1
24 +D1-F1:X4:11 +13/5C ST 2,5 -XB4
Saddle Jumper
25 +D1-F1:X4:13 +13/5C ST 2,5
Insertable Insertable
Target designation Jumper Jumper Target designation Placement Terminal Type
26 +D1-F1:X4:14 +13/6C ST 2,5
1 +P-T3:1S2 +5/9B ST 2,5
D

2 +P-T1:1S1 +5/9B ST 2,5


M1
3 +P-T2:1S1 +5/9C ST 2,5
-XB3
Saddle Jumper 4 +P-T3:1S1 +5/9C ST 2,5
Insertable Insertable
Target designation Jumper Jumper Target designation Placement Terminal Type

1 +M2-XB31:15 +4/7D ST 2,5


M1
E

2 +M2-XB31:16 +4/7F ST 2,5 -XB30


Saddle Jumper
3 +M2-XB31:17 +4/7D ST 2,5
Insertable Insertable
Target designation Jumper Jumper Target designation Placement Terminal Type
4 +M2-XB31:18 +4/7F ST 2,5
1 +P-Q2:S6:1 +4/7B ST 2,5
5 +M2-XB31:19 +4/7D ST 2,5
2 +P-Q2:S6:4 +4/8C ST 2,5
6 +M2-XB31:20 +4/7F ST 2,5
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 16
B 26/10/2023 Revision 1 Terminal diagram C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Terminal diagram SEC_LEVEL1_F13_003


A

M1 M2
-XB30 -XB31
Saddle Jumper Saddle Jumper
Insertable Insertable Insertable Insertable

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
Target designation Jumper Jumper Target designation Placement Terminal Type Target designation Jumper Jumper Target designation Placement Terminal Type

3 +P-Q2:S8:1 +4/9B ST 2,5 14 +11/3E ST 2,5

4 +P-Q2:S8:4 +4/9C ST 2,5 +M1-XB3:1 15 +P-Q1:19 +4/7E ST 2,5

5 +4/6B ST 2,5 +M1-XB3:2 16 +P-Q1:20 +4/7E ST 2,5


B

6 +P-Q2:S5:1 +4/7B ST 2,5 +M1-XB3:3 17 +P-Q1:21 +4/7E ST 2,5

6 +P-Q2:S9:1 +4/7B ST 2,5 +M1-XB3:4 18 +P-Q1:22 +4/7E ST 2,5

7 +P-Q2:S5:4 +4/7C ST 2,5 +M1-XB3:5 19 +P-Q1:23 +4/7E ST 2,5

8 +P-Q2:S9:4 +4/7C ST 2,5 +M1-XB3:6 20 +P-Q1:24 +4/7E ST 2,5

+M1-XB3:7 21 +P-Q1:25 +4/8E ST 2,5

+M1-XB3:8 22 +P-Q1:26 +4/8E ST 2,5


C

M2
-XB31 +M1-XB3:9 23 +P-Q1:27 +4/8E ST 2,5
Saddle Jumper
+M1-XB3:10 24 +P-Q1:28 +4/8E ST 2,5
Insertable Insertable
Target designation Jumper Jumper Target designation Placement Terminal Type
25 90 +4/10E ST 2,5
+M1-Q6:4 1 67 +10/2D ST 2,5
26 91 +4/10E ST 2,5
+M1-Q6:2 2 68 +10/2E ST 2,5

+M1-XB1:11 3 69 +10/4E ST 2,5


D

+M1-XB1:1 4 70 +10/4F ST 2,5

+M1-XB1:16 5 71 +10/5E ST 2,5

+M1-XB1:2 6 88 +11/3F ST 2,5

+M1-XB1:19 7 +P-Q1:11 +11/3E ST 2,5

8 77+ +4/9E ST 2,5


E

9 78- +4/10E ST 2,5

+M1-XB3:11 10 74 +12/3B ST 2,5

+M1-XB3:14 11 +P-Q1:7 +12/3C ST 2,5

+M1-XB3:13 12 +P-Q1:5 +12/3C ST 2,5

+M1-XB3:15 13 +P-Q1:17 +11/3E ST 2,5


F

Schneider Electric Project Name Page description Order Number / WBS Number Page 17
B 26/10/2023 Revision 1 Terminal diagram C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Parts list F01_SEC_002-PART-LV

Device tag Qty Designation Order number Part number Panel Location Manufacturer Remark
A

Easergy P3U20, 4L, 1U, 10DI/5DO, Uaux: 48-230V, DI: 110-230V, 2 x


-F1 1 REL52018 SE.REL52018 DM1-A_002 D1 Schneider Electric
RJ-45
-H1 1 Green complete pilot light Ø22 SEE TABLE SE.PL_GREEN DM1-A_002 D1 -

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
-H2 1 Red complete pilot light Ø22 SEE TABLE SE.PL_RED DM1-A_002 D1 -
Harmony XB4 black selector Key switch Metal head Ø22
-S41 1 XB4BG41 SE.XB4BG41 DM1-A_002 D1 Schneider Electric
2-position stay put 1NO Contact Key withdrawable in any position
-S41 2 Harmony XB5 1NO contact ZBE101 SE.ZBE101 DM1-A_002 D1 Schneider Electric
B

-S41 3 Harmony XB5 1NC contact ZBE102 SE.ZBE102 DM1-A_002 D1 Schneider Electric
Harmony XB5 green flush complete pushbutton Ø22
-1S1 1 XB5AA31 SE.XB5AA31 DM1-A_002 D1 Schneider Electric
spring return 1NO unmarked
-1S1 1 Harmony XB5 Black padlock flap ZB4BZ62 SE.ZB4BZ62 DM1-A_002 D1 Schneider Electric
Harmony XB5 Red flush complete pushbutton Ø22
-1S2 1 XB5AA41 SE.XB5AA41 DM1-A_002 D1 Schneider Electric
spring return 1NO unmarked
-1S2 1 Harmony XB5 Black padlock flap ZB4BZ62 SE.ZB4BZ62 DM1-A_002 D1 Schneider Electric
ABB (Asea Brown
-X1.2 1 Essailec current test box 1SNA166625R2000 ABB.1SNA166625R2000 DM1-A_002 D1
Boveri AG)
C

-CN 8 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact

-Q4 1 Miniature circuit breaker iC60N, 1P, 2A, C A9F74102 SE.A9F74102 DM1-A_002 M1 Schneider Electric

-Q5 1 Miniature circuit breaker iC60N, 2P, 10A, C A9F74210 SE.A9F74210 DM1-A_002 M1 Schneider Electric

-Q6 1 Miniature circuit breaker iC60N, 2P, 10A, C A9F74210 SE.A9F74210 DM1-A_002 M1 Schneider Electric

-XB1 20 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact

-XB2 26 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact
D

-XB3 15 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact

-XB4 4 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact

-XB30 9 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M1 Phoenix Contact

-XB31 26 Feed-through terminal with spring-cage connection 3031212 PXC.3031212 DM1-A_002 M2 Phoenix Contact

-EH1 1 Space Heater, 50W, 220/240VAC, 50/60Hz 3736436-220V LOCAL.3736436-220V DM1-A_002 P Schneider Electric

-H21 1 VPIS LED voltage indicators VPIS SE.SM6.VPIS DM1-A_002 P Schneider Electric
E

-Q1 1 SF6 Circuit Breaker 3P Fixed type Detail See SLD SM6.CB.SF SE.SM6.CB.FIXED DM1-A_002 P Schneider Electric

-Q1 1 "M" Spring Charging Motor SM6.M SE.SM6.M DM1-A_002 P Schneider Electric

-Q1 1 "YF" Closing Coil; "KN" RI Anti Pumping Relay + Socket SM6.YF SE.SM6.YF DM1-A_002 P Schneider Electric

-Q1 1 "YO1" Opening Coil SM6.YO1 SE.SM6.YO1 DM1-A_002 P Schneider Electric

-Q1 1 1 Set Locking 50 Tubular (3 Lock barrel + 2 Key) + Kit Lock Type 50/3730356A+3731441 SE.SM6.TYPE50 DM1-A_002 P Schneider Electric
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 18
B 26/10/2023 Revision 1 Part list C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30
1 2 3 4 5 6 7 8 9 10

Parts list F01_SEC_002-PART-LV

Device tag Qty Designation Order number Part number Panel Location Manufacturer Remark
A

-Q2 1 Disconnecting Switch 3P SM6.DS SE.SM6.DS.4C/O DM1-A_002 P Schneider Electric

-Q3 1 Earthing Switch 3P SM6.ES SE.SM6.ES DM1-A_002 P Schneider Electric

The technical information contained in this document is the exclusive property of Schneider Electric and can not be used or disclosed to third parties of any kind without its written consent. Only those drawings and diagrams remitted after order booking are binding for execution. All devices shown in this diagrams are in open position, drawn out with operating mechanisms discharged and all power sources off.
-T1 1 Current Transformer Detail See SLD SEE SLD CT-1P/2S DM1-A_002 P -

-T2 1 Current Transformer Detail See SLD SEE SLD CT-1P/2S DM1-A_002 P -

-T3 1 Current Transformer Detail See SLD SEE SLD CT-1P/2S DM1-A_002 P -
B

-B1L1-3 1 Easergy TH110 Wireless thermal sensor EMS59440 SE.EMS59440 DM1-A_002 S4 Schneider Electric

-B1L1-3 1 Thermal sensor NFC Sticker for TH110 REL52862 SE.NFC STICKER DM1-A_002 S4 Schneider Electric
C
D
E
F

Schneider Electric Project Name Page description Order Number / WBS Number Page 19
B 26/10/2023 Revision 1 Part list C2030-4050932 Total pages 19
A 18/10/2023 First Issued DM1-A FOR MEIKO DM1-A Customer Drawing number Drawing number
Rev. Date Revision description Rev. Date Revision description Z-4050932-30-002-1-30