0% found this document useful (0 votes)
364 views98 pages

UK Price List 2024 LR

The document outlines Panasonic's air conditioning solutions for 2025/2026, emphasizing their commitment to sustainability and advanced technology, including the nanoe™ X technology for improved indoor air quality. It details various product offerings, including domestic and commercial systems, alongside tools for HVAC professionals to aid in design and installation. Panasonic's extensive experience and global reach position it as a leader in the heating and cooling sector.

Uploaded by

Andy Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
364 views98 pages

UK Price List 2024 LR

The document outlines Panasonic's air conditioning solutions for 2025/2026, emphasizing their commitment to sustainability and advanced technology, including the nanoe™ X technology for improved indoor air quality. It details various product offerings, including domestic and commercial systems, alongside tools for HVAC professionals to aid in design and installation. Panasonic's extensive experience and global reach position it as a leader in the heating and cooling sector.

Uploaded by

Andy Dang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 98

AIR TO AIR PRICE LIST

2025 / 2026

PANASONIC TOTAL SOLUTION


Panasonic environmental vision 2050
To achieve “a better life” and “a sustainable global environment,” Panasonic will work towards creation
and more efficient utilisation of energy which exceeds the amount of energy used, aiming for a society
with clean energy and a more comfortable lifestyle.

Vitalise the future with air. Bringing nature’s balance indoors.


These are times of exceptional challenge. nanoe™ X, technology with the benefits of hydroxyl radicals.
If the world is to move forward confidently, it must overcome the In today’s health-conscious world, we care about taking exercise, we
serious threats of the new global pandemics and the degrading of the care about what we eat and what we touch, we also care about what
environment. It must find ways large and small to reduce the we breathe – and technology exists to bring good outdoor air, indoors.
stresses that affect people’s health and the stability of their
communities.

100% Panasonic, the DNA of Japanese craftsmanship A globally trusted air conditioning brand.
Applying advanced technologies that truly make life better, we live by Panasonic – leading the way in Heating and Cooling.
an unparalleled commitment to product quality. With more than 50 years of experience, selling to more than 120
Panasonic is building on the Japanese tradition of uncompromising countries around the world, Panasonic is one of the leaders in the
quality control worldwide, developing and manufacturing fine heating and cooling sector.
products and delivering them to customers everywhere. With a diverse network of production and R&D facilities, Panasonic
delivers innovative products incorporating cutting-edge technologies
that set the standard for air conditioners worldwide.
Editorial Commercial air to air - PACi
Panasonic – leading the way in Heating and Cooling. With 65 years of The commercial range is continuously being improved to offer
experience, selling to more than 120 countries around the world, the optimal solutions. High performance, silent operation and
Panasonic is one of the leaders in the heating and cooling sector. a wide range of indoor units and connectivity available.

Bringing nature’s balance indoors. New Jet Air Stream.


nanoe™ X, technology with the benefits of hydroxyl The new PACi NX indoor units designed for large
radicals that have the capacity to inhibit pollutants, spaces that require high air distribution, such as
viruses, and bacteria and deodorise. gymnasiums, production areas, and warehouses.
They ensure optimal user comfort, a quiet
environment, and are much easier to install than
other systems.

Domestic Ventilation
Panasonic has developed a range of domestic products Panasonic ventilation solutions for maximum savings and easy
designed for you and your clients. integration.

Etherea: a very welcome addition to Energy recovery ventilation.


your home. Panasonic energy recovery ventilations (ERV) help to
The smart, Etherea comes with the nanoe™ X improve your comfort and energy-saving plan.
(Generator Mark 3) and built-in Wi-Fi which enables Introducing the ERV with DX coil - HRPT Series,
advanced smart control and voice assistant, now with specifically designed for commercial applications or
an easier and quicker set-up. collective residential buildings, offering highly
efficient heat recovery.

Commercial VRF Systems - ECOi and ECO G Refrigeration


Panasonic provides an extensive range of solutions for Panasonic CO2 condensing units. Natural refrigerant solution
medium and large sized buildings, combining the best options for showcases and cold rooms. Reliable quality - made in
to satisfy all needs and site restrictions. Japan.

Mini ECOi LZ2 Series R32. CR Series 20 HP MT/LT model.


Outstanding efficiency in a compact body and The CR Series now includes a 20 HP medium/low R744
continuous operation even at extreme ambient temperature model, a highly efficient multi-
temperatures. compressor solution.
The smaller footprint of the unit and the maximum
piping length of 100 m allow for flexible installation in
light refrigeration projects.

Quality Management System Certificate Environmental Management System Certificate

ISO 9001: 2015 GB/T 19001-2016/ISO 9001: 2015 ISO 14001: 2015 GB/T 24001-2016/ISO 14001: 2015
Panasonic Appliances Air-Conditioning Panasonic Appliances Air-Conditioning Panasonic Appliances Air-Conditioning Panasonic Appliances Air-Conditioning
Malaysia. Sdn.Bhd. (GuangZhou) Co., Ltd. Malaysia Sdn.Bhd. (GuangZhou) Co., Ltd.
Cert. No.: QMS 00413 Registration Number: 01218Q30835R8L Cert. No.: EMS 00109 Registration Number: 02118E10944R7M
Bringing nature’s balance indoors
nanoe™ X, technology with the benefits of hydroxyl radicals.
In today’s health-conscious world, we care about taking exercise, we care about what
we eat and what we touch, we also care about what we breathe – and technology
exists to bring good outdoor air, indoors.

Cumulative global
shipments of nanoe™
devices exceed
100 million units*
* From July 2024, the results apply to
all other products with nanoe™ X
devices, including heating and
cooling.

Effective on fabrics and surfaces. Longer lifespan. Huge quantity. Maintenance-free.

The image shows nanoeTM X Generator Mark 3.

1 | At one billionth of a metre, nanoe™ X 2 | Contained in tiny water particles, 3 | nanoe™ X Generator Mark 3 produces 4 | No service and maintenance required.
is much smaller than steam and can nanoe™ X has a long lifespan, which is 48 trillion hydroxyl radicals per nanoe™ X is a filter free solution that
deeply penetrate cloth fabrics to about 600 seconds, to spread easily second. Greater amounts of hydroxyl does not require maintenance, as its
deodorise. around the room. radicals contained in nanoe™ X lead to atomisation electrode is enveloped
higher performance on inhibition of with water during its generation
pollutants. process and it is made with Titatium.

7 effects of nanoe™ X Deodorises Capacity to inhibit 5 types of pollutants Moisturises

* Refer to https://aircon.panasonic.eu for


more details and validation data.

Odours Bacteria and Mould Allergens Pollen Hazardous Skin and hair
viruses substances

First nanoe™ device was developed by Panasonic in 2003


Generator: nanoe™ Generator: nanoe™ X
2003 Mark 1 - 2016 Mark 2 - 2019 Mark 3 - 2022
480 billion hydroxyl radicals/sec 4,8 trillion hydroxyl radicals/sec 9,6 trillion hydroxyl radicals/sec 48 trillion hydroxyl radicals/sec
Ion particle
structure 10x 20x 100x
Hydroxyl radicals times times times

Licensed in VDI 6022


Certification of a HVAC system under VDI 6022 guarantees that the system fulfills the market’s strictest hygiene requirements.

VDI 6022 – Part 5 1) Certification. VDI 6022 – Part 1 1) & 1.1 2) Certification.
or allergy suf uirements
le f req
ab
fe
Avoidance of allergenic exposure. ne fu
Ventilation and indoor-air quality.
rer
it

lfil
su

i
Hyg
s

led

Inhibits a wide range of harmful bacteria, scientifically


Panasonic nanoe™ X technology improving
VD

1 .1

scientifically
tested tested
I6

02
rt

VD
I 6 0 2 2 P a rt 5 2P Pa

Cert. No.:
viruses, mould, pollen and allergens. a rt 1 a n d
Cert. No.:
indoor air quality.
ALR-100-408-23 VDI-6022-505-23

2023 2023

1) Certification mark only valid for nanoeTM X Generator Mark 3. 2) Certification mark only valid for nanoeTM X Generator Mark 2 and Mark 3.

4
PRO Club. The professional website of Panasonic
Panasonic has an impressive range of support services for designers, specifiers, engineers
and distributors working in the heating and cooling markets.

Aquarea Designer - online tool Residential ventilation selection tool


With Panasonic’s online tool, projects can be The tool contains all the information the HVAC
developed simply and easily. The developed tool AQUAREA DESIGNER professionals need for their residential ventilation projects
is optimised to help HVAC professionals easily (specifications, technical manuals, etc.) as well as a
identify the most appropriate Aquarea air to water heat calculator of the performance curves.
pump for a particular application.

Panasonic DX PRO Designer AC SELECT


The Panasonic DX PRO Designer will be rebuilt Use AC SELECT to choose and configure your hydronic
with an improved user experience. The software solution.
runs in the cloud and is always up to date with Panasonic online selection tool offers an easy and quick
the latest products. An intuitive interface supports the solution to specify all the hydronics ranges and rooftops at
most complicated designs, allows online sharing and required conditions.
project collaboration with multilingual support.

Refrigeration designer BIM & AutoCAD Support


This easy to use design tool supports engineers, Panasonic offers a wide range of HVAC&R products with
installers, and technicians to make a quick BIM (Building Information Modelling) objects in Revit
calculation for commercial refrigeration systems. format and AutoCAD files, providing comprehensive
support for design offices, consultants, and installers in
planning projects.

5
GENERAL INDEX

Panasonic domestic air


to air heat pump
Panasonic has developed a range of products
designed for you, better than ever before.
Above all, it is also a range for air conditioning
professionals, such as yourself, thanks to its
broad range of products which are capable of
conditioning rooms of all sizes – always with
optimal efficiency and incomparable ease of
installation.

6
DOMESTIC

New 2025
Power Heat Multi system. Reliable heating for cold winters.
· Powerful heating of two or three rooms with one outdoor unit
· Reliable heating even at -25 °C
· Equipped with base pan heater
· High energy efficiency
· Etherea indoor units with nanoe™ X technology to improve protection 24/7

RAC Solo, the compact air conditioner without an outdoor unit.


· Slim and compact, only 165 mm deep
· No outdoor unit, only two holes in the wall
· Optimised performance with DC Inverter technology
· Easy and flexible installation

Etherea with nanoe™ X technology.


· nanoe™ X technology to improve protection 24/7 (Generator Mark 3)
· Sleek and stylish design, in graphite grey, silver and matt white colours
· Improved SEER / SCOP for top class energy efficiency
· Built-in Wi-Fi, now with easier and faster set-up
· Compatible with Google Assistant and Amazon Alexa

Wall-mounted TZ super-compact.
· The perfect air conditioner for the smallest spaces in your home (only 779 mm wide)
· nanoe™ X technology to improve protection 24/7
· Built-in Wi-Fi, now with easier and faster set-up
· Compatible with Google Assistant and Amazon Alexa
· High energy savings

Wall-mounted indoor units, designed for simple installation and maintenance.


The full range of wall-mounted indoor units has been carefully designed for simple, stress-free installation and ongoing
maintenance.
Welcome to the connected world of Panasonic Comfort Cloud App.
The Panasonic Comfort Cloud App put total control of your indoor air quality at your fingertips.
· Easily manage your comfort and air quality anytime, anywhere
· Monitor energy consumption and maximise energy savings by comparing the energy usage patterns

7
GENERAL INDEX

Domestic air conditioner R32 range


Page Single split units 2,0 kW 2,5 kW 3,5 kW 4,2 kW 5,0 kW 6,0 kW 7,1 kW

Wall-mounted Etherea · R32

CS-XZ20ZKEW-H CS-XZ25ZKEW-H CS-XZ35ZKEW-H CS-XZ42ZKEW-H


CU-Z20ZKE CU-Z25ZKE CU-Z35ZKE CU-Z42ZKE

P. 10
CS-XZ20ZKEW CS-XZ25ZKEW CS-XZ35ZKEW CS-XZ50ZKEW
CU-Z20ZKE CU-Z25ZKE CU-Z35ZKE CU-Z50ZKE

CS-Z20ZKEW CS-Z25ZKEW CS-Z35ZKEW CS-Z42ZKEW CS-Z50ZKEW CS-Z71ZKEW


CU-Z20ZKE CU-Z25ZKE CU-Z35ZKE CU-Z42ZKE CU-Z50ZKE CU-Z71ZKE

Wall-mounted TZ super-compact · R32

P. 11
CS-TZ20ZKEW CS-TZ25ZKEW CS-TZ35ZKEW CS-TZ42ZKEW CS-TZ50ZKEW CS-TZ60ZKEW CS-TZ71ZKEW
CU-TZ20ZKE CU-TZ25ZKE CU-TZ35ZKE CU-TZ42ZKE CU-TZ50ZKE CU-TZ60ZKE CU-TZ71ZKE

Wall-mounted BZ super-compact · R32

P. 11
CS-BZ25ZKE CS-BZ35ZKE CS-BZ50ZKE CS-BZ60ZKE
CU-BZ25ZKE CU-BZ35ZKE CU-BZ50ZKE CU-BZ60ZKE

Floor console · R32

P. 12
CS-Z25UFEAW CS-Z35UFEAW CS-Z50UFEAW
CU-Z25UBEA CU-Z35UBEA CU-Z50UBEA

Low static pressure hide-away · R32

P. 13
CS-Z25UD3EAW CS-Z35UD3EAW CS-Z50UD3EAW CS-Z60UD3EAW
CU-Z25UBEA CU-Z35UBEA CU-Z50UBEA CU-Z60UBEA

Page Stand-alone units 1,7 kW 2,0 kW 2,5 kW 3,0 kW

NEW RAC Solo · R290 / R32

P. 18 P-MOG16IC5-E P-MOZ20IC5-E P-MOZ25IC5-E P-MOZ30IC5-E

Try Panasonic's augmented Configure your multi split system


reality tool, the AR Heat in a few steps using our
Pump Viewer. online tool and see all
possible combinations.

8
DOMESTIC INDEX DOMESTIC

Page Free Multi indoors 1,6 kW 2,0 kW 2,5 kW 3,5 kW 4,2 kW 5,0 kW 6,0 kW 7,1 kW

Wall-mounted Etherea

CS-XZ20ZKEW-H CS-XZ25ZKEW-H CS-XZ35ZKEW-H CS-XZ42ZKEW-H

P. 14
CS-XZ20ZKEW CS-XZ25ZKEW CS-XZ35ZKEW CS-XZ50ZKEW

CS-MZ16ZKE CS-Z20ZKEW CS-Z25ZKEW CS-Z35ZKEW CS-Z42ZKEW CS-Z50ZKEW CS-Z71ZKEW

Wall-mounted TZ super-compact

P. 15
CS-MTZ16ZKE CS-TZ20ZKEW CS-TZ25ZKEW CS-TZ35ZKEW CS-TZ42ZKEW CS-TZ50ZKEW CS-TZ60ZKEW CS-TZ71ZKEW

Floor console

P. 15
CS-MZ20UFEA CS-Z25UFEAW CS-Z35UFEAW CS-Z50UFEAW

4 way 60x60 cassette

P. 15
S-M20PY3E S-25PY3E S-36PY3E S-50PY3E S-60PY3E
CZ-KPY4 CZ-KPY4 CZ-KPY4 CZ-KPY4 CZ-KPY4

Low static pressure hide-away

P. 15
CS-MZ20UD3EA CS-Z25UD3EAW CS-Z35UD3EAW CS-Z50UD3EAW CS-Z60UD3EAW

Page Free Multi 3,2 ~ 6,0 kW 3,2 ~ 6,0 kW 3,2 ~ 7,7 kW 4,5 ~ 9,5 kW 4,5 ~ 11,2 kW 4,5 ~ 11,5 kW 4,5 ~ 14,7 kW 4,5 ~ 18,3 kW

Outdoor units Free


P. 14
Multi system Z · R32

CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE CU-3Z52TBE CU-3Z68TBE CU-4Z68TBE CU-4Z80TBE CU-5Z90TBE

Power Heat Multi system 5,0 kW (2 room) 7,5 kW (3 room)

NEW Outdoor units Power Heat


P. 16
Multi system · R32

CU-2Z50ABEC CU-3Z75ABEC

Page Multi wall TZ outdoors 3,2 ~ 6,0 kW 3,2 ~ 7,7 kW 4,5 ~ 9,5 kW

Outdoor units Multi TZ for wall


P. 17
TZ indoors · R32

CU-2TZ41TBE CU-2TZ50TBE CU-3TZ52TBE

9
GENERAL INDEX

Single split
Wall-mounted Etherea · R32 Built-in

nanoe™ X (Generator Mark 3) and inside cleaning.


Built-in Wi-Fi for connectivity via Panasonic Comfort
Cloud App.
Operation range down to -20 °C in heating.

Kit (remote controller included) Indoor unit Outdoor unit RRP


Nominal capacity SEER SCOP Dimension / Weight Dimension 1) / Weight
Cool UK Heat UK A+++ to D A+++ to D HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
Kit graphite grey
2.0 kW KIT-XZ20-ZKE-H 2.05 2.09 / 2.07 2.80 2.78 8.70 A+++ 4.80 A++ CS-XZ20ZKEW-H 295 x 870 x 229 / 10 CU-Z20ZKE 542 x 780 x 289 / 27 1,335
2.5 kW KIT-XZ25-ZKE-H 2.50 2.58 / 2.52 3.40 3.20 9.50 A+++ 5.20 A+++ CS-XZ25ZKEW-H 295 x 870 x 229 / 10 CU-Z25ZKE 542 x 780 x 289 / 27 1,468
1ph
3.5 kW KIT-XZ35-ZKE-H 3.50 3.47 / 3.28 4.00 3.81 9.50 A+++ 5.20 A+++ CS-XZ35ZKEW-H 295 x 870 x 229 / 11 CU-Z35ZKE 542 x 780 x 289 / 31 1,634
4.2 kW KIT-XZ42-ZKE-H 4.20 4.25 / 4.07 5.30 4.78 7.10 A++ 4.30 A+ CS-XZ42ZKEW-H 295 x 870 x 229 / 10 CU-Z42ZKE 542 x 780 x 289 / 31 1,887
Kit silver
2.0 kW KIT-XZ20-ZKE 2.05 2.09 / 2.07 2.80 2.78 8.70 A+++ 4.80 A++ CS-XZ20ZKEW 295 x 870 x 229 / 10 CU-Z20ZKE 542 x 780 x 289 / 27 1,291
2.5 kW KIT-XZ25-ZKE 2.50 2.58 / 2.52 3.40 3.20 9.50 A+++ 5.20 A+++ CS-XZ25ZKEW 295 x 870 x 229 / 10 CU-Z25ZKE 542 x 780 x 289 / 27 1,415
1ph
3.5 kW KIT-XZ35-ZKE 3.50 3.47 / 3.28 4.00 3.81 9.50 A+++ 5.20 A+++ CS-XZ35ZKEW 295 x 870 x 229 / 11 CU-Z35ZKE 542 x 780 x 289 / 31 1,575
5.0 kW KIT-XZ50-ZKE 5.00 4.70 / 4.07 5.80 5.57 8.50 A+++ 4.80 A++ CS-XZ50ZKEW 295 x 1 040 x 244 / 12 CU-Z50ZKE 695 x 875 x 320 / 40 2,267
Kit matt white
2.0 kW KIT-Z20-ZKE 2.05 2.09 / 2.07 2.80 2.78 8.70 A+++ 4.80 A++ CS-Z20ZKEW 295 x 870 x 229 / 10 CU-Z20ZKE 542 x 780 x 289 / 27 1,236
2.5 kW KIT-Z25-ZKE 2.50 2.58 / 2.52 3.40 3.20 9.50 A+++ 5.20 A+++ CS-Z25ZKEW 295 x 870 x 229 / 10 CU-Z25ZKE 542 x 780 x 289 / 27 1,351
3.5 kW KIT-Z35-ZKE 3.50 3.47 / 3.28 4.00 3.81 9.50 A+++ 5.20 A+++ CS-Z35ZKEW 295 x 870 x 229 / 11 CU-Z35ZKE 542 x 780 x 289 / 31 1,489
1ph
4.2 kW KIT-Z42-ZKE 4.20 4.25 / 4.07 5.30 4.78 7.10 A++ 4.30 A+ CS-Z42ZKEW 295 x 870 x 229 / 10 CU-Z42ZKE 542 x 780 x 289 / 31 1,753
5.0 kW KIT-Z50-ZKE 5.00 4.70 / 4.07 5.80 5.57 8.50 A+++ 4.80 A++ CS-Z50ZKEW 295 x 1 040 x 244 / 12 CU-Z50ZKE 695 x 875 x 320 / 40 2,030
7.1 kW KIT-Z71-ZKE 7.10 6.68 / 5.52 8.20 7.15 6.50 A++ 4.20 A+ CS-Z71ZKEW 295 x 1 040 x 244 / 13 CU-Z71ZKE 695 x 875 x 320 / 45 2,848

Piping information Electrical information (power supply to indoor)


Kit kW 2,0 2,5 3,5 4,2 5,0 7,1 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-⅜ ¼-½ ¼-½ ¼-⅝ Kit kW 2,0 2,5 3,5 4,2 5,0 7,1
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30 3 ~ 30 Recommended fuse A 16 16 16 16 16 20
Elevation difference (in / out) m 15 15 15 15 15 20 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 7,5 7,5 7,5 10
Additional gas amount g/m 10 10 10 10 15 25 Order our full RAC range online at
www.panasonic-hvac-direct.co.uk
1) Add 70 mm for piping port.

Hi-durability outdoor units


Panasonic RAC, PAC and VRF outdoor units have been treated for high resistance to corrosion (rust and
salty air) to ensure long-lasting performance. No need for expensive and time consuming third part
coatings. Tests have been completed under the norm ASTM B117 for 1000 hours.

Specially protected parts.

Outer body

Accumulator Receiver
tank oil separator

Heat exchanger
(Bluefin condenser)

Note: Selecting this unit does not completely eliminate the possibility of rust developing. For details
concerning unit installation and maintenance, please consult an authorised dealer.

10
DOMESTIC INDEX DOMESTIC

Single split
Wall-mounted TZ super-compact · R32 Built-in

nanoe™ X technology to improve protection 24/7.


Built-in Wi-Fi for connectivity via Panasonic Comfort Cloud App.
Operation range down to -15 °C in heating.

Kit (remote controller included) Indoor unit Outdoor unit RRP


Nominal capacity SEER SCOP Dimension / Weight Dimension 1) / Weight
Cool UK Heat UK A+++ to D A+++ to D HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
2.0 kW KIT-TZ20-ZKE 2.00 1.87 / 1.85 2.70 2.50 7.00 A++ 4.60 A++ CS-TZ20ZKEW 290 x 779 x 209 / 8 CU-TZ20ZKE 542 x 780 x 289 / 24 940
2.5 kW KIT-TZ25-ZKE 2.50 2.34 / 2.30 3.30 2.91 7.10 A++ 4.60 A++ CS-TZ25ZKEW 290 x 779 x 209 / 8 CU-TZ25ZKE 542 x 780 x 289 / 25 1,083
3.5 kW KIT-TZ35-ZKE 3.50 3.37 / 2.95 4.00 3.61 6.80 A++ 4.60 A++ CS-TZ35ZKEW 290 x 779 x 209 / 8 CU-TZ35ZKE 542 x 780 x 289 / 29 1,252
1ph 4.2 kW KIT-TZ42-ZKE 4.20 3.94 / 3.17 5.00 4.70 6.40 A++ 4.10 A+ CS-TZ42ZKEW 290 x 779 x 209 / 8 CU-TZ42ZKE 542 x 780 x 289 / 31 1,493
5.0 kW KIT-TZ50-ZKE 5.00 4.69 / 4.31 5.80 5.25 6.90 A++ 4.50 A+ CS-TZ50ZKEW 290 x 779 x 209 / 8 CU-TZ50ZKE 619 x 824 x 299 / 35 1,593
6.0 kW KIT-TZ60-ZKE 6.00 5.70 / 4.65 7.00 5.70 6.80 A++ 4.30 A+ CS-TZ60ZKEW 295 x 1 040 x 244 / 12 CU-TZ60ZKE 619 x 824 x 299 / 35 1,970
7.1 kW KIT-TZ71-ZKE 7.10 6.68 / 5.25 8.20 7.15 6.20 A++ 4.10 A+ CS-TZ71ZKEW 295 x 1 040 x 244 / 13 CU-TZ71ZKE 695 x 875 x 320 / 45 2,272

Piping information Electrical information (power supply to indoor)


Kit kW 2,0 2,5 3,5 4,2 5,0 6,0 7,1 Single phase
Piping diameter (liquid - gas) Inch ¼- ⅜ ¼- ⅜ ¼- ⅜ ¼- ½ ¼- ½ ¼- ½ ¼- ⅝ Kit kW 2,0 2,5 3,5 4,2 5,0 6,0 7,1
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 30 3 ~ 30 Recommended fuse A 16 16 16 16 16 20 20
Elevation difference (in / out) m 15 15 15 15 15 15 20 4x 4x 4x 4x 4x 4x 4x
Connection in. / out. mm²
1,5 1,5 1,5 1,5 2,5 2,5 2,5
Pre-charged pipe length m 7,5 7,5 7,5 7,5 10 10 10
Additional gas amount g/m 10 10 10 10 15 15 25
Order our full RAC range online at
1) Add 70 mm for piping port. www.panasonic-hvac-direct.co.uk

Wall-mounted BZ super-compact · R32 Optional

Cleaner air with PM2,5 filter.


Optional Wi-Fi control via Panasonic Comfort Cloud App
(CZ-TACG1 required).
Operation range down to -15 °C in heating.
Kit (remote controller included) Indoor unit Outdoor unit RRP
Nominal capacity SEER SCOP Dimension / Weight Dimension 1) / Weight
Cool UK Heat UK A+++ to D A+++ to D HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
2.5 kW KIT-BZ25-ZKE 2.50 2.29 / 2.26 3.15 2.50 6.30 A++ 4.20 A+ CS-BZ25ZKE 290 x 779 x 209 / 8 CU-BZ25ZKE 542 x 780 x 289 / 24 706
3.5 kW KIT-BZ35-ZKE 3.30 3.08 / 2.83 3.70 3.05 6.30 A++ 4.20 A+ CS-BZ35ZKE 290 x 779 x 209 / 8 CU-BZ35ZKE 542 x 780 x 289 / 25 799
1ph
5.0 kW KIT-BZ50-ZKE 5.00 4.59 / 3.64 5.40 5.25 6.50 A++ 4.20 A+ CS-BZ50ZKE 290 x 779 x 209 / 8 CU-BZ50ZKE 619 x 824 x 299 / 35 1,246
6.0 kW KIT-BZ60-ZKE 6.00 5.25 / 4.36 6.80 5.64 6.40 A++ 4.10 A+ CS-BZ60ZKE 290 x 779 x 209 / 9 CU-BZ60ZKE 695 x 875 x 320 / 40 1,571

Piping information Electrical information (power supply to indoor)


Kit kW 2,5 3,5 5,0 6,0 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-½ ¼-½ Kit kW 2,5 3,5 5,0 6,0
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 30 Recommended fuse A 16 16 16 20
Elevation difference (in / out) m 15 15 15 15 Connection in. / out. mm² 4x1,5 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 10 7,5
Additional gas amount g/m 10 10 15 15 Order our full RAC range online at
www.panasonic-hvac-direct.co.uk
1) Add 70 mm for piping port.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
11
GENERAL INDEX

Single split
Floor console · R32 Optional

nanoe™ X technology to improve protection 24/7.


Optional Wi-Fi control via Panasonic Comfort Cloud App
(CZ-TACG1 required).
Operation range down to -15 °C in heating.

Kit (remote controller included) Indoor unit Outdoor unit RRP


Nominal capacity SEER SCOP Dimension / Weight Dimension 1) / Weight
Cool UK Heat UK A+++ to D A+++ to D HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
2.5 kW KIT-Z25-UFE 2.50 2.36 / 2.19 3.40 3.45 7.90 A++ 4.60 A++ CS-Z25UFEAW 600 x 750 x 207 / 13 CU-Z25UBEA 542 x 780 x 289 / 33 1,782
1ph 3.5 kW KIT-Z35-UFE 3.50 3.30 / 2.83 4.30 4.13 8.10 A++ 4.60 A++ CS-Z35UFEAW 600 x 750 x 207 / 13 CU-Z35UBEA 619 x 824 x 299 / 35 1,922
5.0 kW KIT-Z50-UFE 5.00 4.72 / 3.47 5.80 5.68 6.70 A++ 4.30 A+ CS-Z50UFEAW 600 x 750 x 207 / 13 CU-Z50UBEA 695 x 875 x 320 / 43 2,328

Piping information Electrical information (power supply to outdoor)


Kit kW 2,5 3,5 5,0 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-½ Kit kW 2,5 3,5 5,0
Pipe length range m 3 ~ 20 3 ~ 20 3 ~ 30 Recommended fuse A 16 16 16
Elevation difference (in / out) m 15 15 20 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5
Pre-charged pipe length m 7,5 7,5 7,5
Additional gas amount g/m 10 10 15
Order our full RAC range online at
1) Add 70 mm for piping port. www.panasonic-hvac-direct.co.uk

Floor console. Efficient comfort and clean air all year round
Floor console with nanoe™ X technology: outstanding efficiency A++, comfort (Super Quiet technology only
20 dB(A)) and better air quality combined in a breakthrough design.

12
DOMESTIC INDEX DOMESTIC

Single split
Low static pressure hide-away · R32 Optional

Eco mode for 20% energy saving.


Optional Wi-Fi control via Panasonic Comfort Cloud App
(CZ-TACG1 required). Drain pump included.
Operation range down to -15 °C in heating.

Kit (remote controller included) Indoor unit Outdoor unit RRP


Nominal capacity SEER SCOP Dimension / Weight Dimension 1) / Weight
Cool UK Heat UK A+++ to D A+++ to D HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
2.5 kW KIT-Z25-UD3 2.50 2.30 / 2.28 3.20 3.16 5.90 A+ 4.20 A+ CS-Z25UD3EAW 200 x 750 x 640 / 19 CU-Z25UBEA 542 x 780 x 289 / 33 1,685
3.5 kW KIT-Z35-UD3 3.50 3.08 / 2.76 4.20 3.54 5.80 A+ 4.10 A+ CS-Z35UD3EAW 200 x 750 x 640 / 19 CU-Z35UBEA 619 x 824 x 299 / 35 1,783
1ph
5.0 kW KIT-Z50-UD3 5.10 3.63 / 2.90 6.10 5.06 5.90 A+ 4.10 A+ CS-Z50UD3EAW 200 x 750 x 640 / 19 CU-Z50UBEA 695 x 875 x 320 / 43 2,298
6.0 kW KIT-Z60-UD3 6.00 4.25 / 3.42 7.00 5.64 5.60 A+ 4.10 A+ CS-Z60UD3EAW 200 x 750 x 640 / 19 CU-Z60UBEA 695 x 875 x 320 / 43 2,485

Piping information Electrical information (power supply to outdoor)

Kit kW 2,5 3,5 5,0 6,0 Single phase

Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-½ ¼-½ Kit kW 2,5 3,5 5,0 6,0

Pipe length range m 3 ~ 20 3 ~ 20 3 ~ 30 3 ~ 30 Recommended fuse A 16 16 16 16

Elevation difference (in / out) m 15 15 20 20 Connection in. / out. mm² 4x1,5 ~ 2,5 4x1,5 ~ 2,5 4x1,5 ~ 2,5 4x1,5 ~ 2,5

Pre-charged pipe length m 7,5 7,5 7,5 7,5


Order our full RAC range online at
Additional gas amount g/m 10 10 15 15
www.panasonic-hvac-direct.co.uk

1) Add 100 mm for indoor unit or 70 mm for outdoor unit for piping port.

Welcome to the connected world of Voice Control. Words do more than


Panasonic Comfort Cloud App. actions.
Whether you are at home or at work, the Boundless control and hands-free help to access
Panasonic Comfort Cloud App puts total control of all the features of your air-to-air heat pump.
your indoor air quality at your fingertips. Maximising your comfort is now a breeze with our
connected air conditioners using the Panasonic Comfort
Cloud App and voice control.

· Remote control. Control and monitor your air conditioners anytime,


anywhere
· Monitor energy consumption. Check the energy consumption of
each individual unit across different time intervals by comparing the
energy usage patterns to maximise energy savings
· nanoe™ X: improving protection 24/7*. Switch on nanoe™ X mode
with cooling OFF / ON and see the nanoe™ X coverage in your space
through a simulation
· Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates
* Only for units compatible with nanoe™ X function.
· Availability of Voice Assistant services varies depending on country and language
· Google and Google Home are trademarks of Google LLC.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
13
GENERAL INDEX

Outdoor units Free Multi system Z


Outdoor units Free Multi system Z · R32
Up to 5 indoor units with a single outdoor unit.
High energy efficiency class A+++ SEER.
Operation range down to -15 °C in heating.

Outdoor unit Nominal capacity SEER SCOP Dimension 1) Weight RRP


Cooling Heating HxWxD
kW kW A+++ to D A+++ to D mm kg £
3,2 ~ 6,0 kW CU-2Z35TBE 3,50 4,20 8,50 A+++ 4,60 A++ 619 x 824 x 299 39 1,329
3,2 ~ 6,0 kW CU-2Z41TBE 4,10 4,60 8,50 A+++ 4,60 A++ 619 x 824 x 299 39 1,509
3,2 ~ 7,7 kW CU-2Z50TBE 5,00 5,60 8,50 A+++ 4,60 A++ 619 x 824 x 299 39 1,663
4,5 ~ 9,5 kW CU-3Z52TBE 5,20 6,80 8,50 A+++ 4,20 A+ 795 x 875 x 320 71 2,005
1ph
4,5 ~ 11,2 kW CU-3Z68TBE 6,80 8,50 8,00 A++ 4,20 A+ 795 x 875 x 320 71 2,368
4,5 ~ 11,5 kW CU-4Z68TBE 6,80 8,50 8,00 A++ 4,20 A+ 795 x 875 x 320 72 2,650
4,5 ~ 14,7 kW CU-4Z80TBE 8,00 9,40 7,90 A++ 4,70 A++ 999 x 940 x 340 80 3,329
4,5 ~ 18,3 kW CU-5Z90TBE 9,00 10,40 8,50 A+++ 4,68 A++ 999 x 940 x 340 81 3,835

Piping information Electrical information (power supply to outdoor)


Outdoor unit kW 2Z35 2Z41 2Z50 3Z52 3Z68 4Z68 4Z80 5Z90 Single phase

¼- ¼- ¼- ¼- ¼- ¼- ¼- ¼- Outdoor unit kW 2Z35 2Z41 2Z50 3Z52 3Z68 4Z68 4Z80 5Z90
Piping diameter (liquid - gas) Inch
⅜ ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ ⅜ Recommended fuse A 16 16 16 16 16 20 20 25
Pipe length range total 2) m 6 ~ 30 6 ~ 30 6 ~ 30 6 ~ 50 6 ~ 60 6 ~ 60 6 ~ 70 6 ~ 80 Recommended power
mm² 2,5 2,5 2,5 2,5 2,5 2,5 2,5 4,0
Pipe length range to one unit m 3 ~ 20 3 ~ 20 3 ~ 20 3 ~ 25 3 ~ 25 3 ~ 25 3 ~ 25 3 ~ 25 cable section

Elevation difference (in / out) m 10 10 10 15 15 15 15 15 4x 4x 4x 4x 4x 4x 4x 4x


Connection in. / out. mm²
Pre-charged pipe length m 20 20 20 30 30 30 45 45 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5

Additional gas amount g/m 15 15 15 20 20 20 20 20

1) Add 70 mm for piping port. 2) Minimum piping length is 3 meters per indoor unit.

Possible outdoor / indoor units combinations


Rooms Outdoor unit Indoor capacity Wall-mounted Etherea Wall-mounted TZ Floor console 4 way 60x60 Low static pressure
connected super-compact cassette hide-away
(Min - Max)
16 20 25 35 42 50 71 16 20 25 35 42 50 60 71 20 25 35 50 20 25 35 50 60 20 25 35 50 60
CU-2Z35TBE 3,2 ~ 6,0 kW • • • • • • • • • • • • 1) • 1) • 1) • • •
2 CU-2Z41TBE 3,2 ~ 6,0 kW • • • • • • • • • • • • 1) • 1) • 1) • • •
CU-2Z50TBE 3,2 ~ 7,7 kW • • • • • 1) • 1) • • • • • 1) • 1) • • • • 1) • 1) • 1) • 1) • 1) • • • • 1)
CU-3Z52TBE 4,5 ~ 9,5 kW • • • • • 1)
• 1)
• • • • • 1)
• 1)
• 1)
• 1)
• 1)
• 1)
• • • • 1)
3
CU-3Z68TBE 4,5 ~ 11,2 kW • • • • • 1)
• 1)
• • • • • 1)
• 1)
• 1)
• 1)
• 1)
• 1)
• 1)
• 2)
• • • • 1) • 1)
CU-4Z68TBE 4,5 ~ 11,5 kW • • • • • 1)
• 1)
• • • • • 1)
• 1)
• 1)
• 1)
• 1)
• 1)
• 1)
• 2)
• • • • 1) • 1)
4
CU-4Z80TBE 4,5 ~ 14,7 kW • • • • • 1) • 1) • 3) • • • • • 1) • 1) • 1) • 3) • 1) • 1) • 1) • 1) • 2) • • • • 1) • 1)
5 CU-5Z90TBE 4,5 ~ 18,3 kW • • • • • 1) • 1) • 3) • • • • • 1) • 1) • 1) • 3) • 1) • 1) • 1) • 1) • 2) • • • • 1) • 1)

Compatible indoor units for multi combinations


Optional wired
remote controller.
CZ-RD517C
Built-in

Wall-mounted Indoor unit Indoor unit Indoor unit Nominal capacity Connection Dimension / Net weight Piping diameter RRP
Etherea graphite grey silver matt white in. / out.
Cooling Heating HxWxD Liquid / Gas Grey Silver White
kW kW mm² mm / kg Inch (mm) £ £ £
1,6 kW — — CS-MZ16ZKE 1,60 2,60 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ⅜ (9,52) — — 359
2,0 kW CS-XZ20ZKEW-H CS-XZ20ZKEW CS-Z20ZKEW 2,00 3,20 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ⅜ (9,52) 479 435 380
2,5 kW CS-XZ25ZKEW-H CS-XZ25ZKEW CS-Z25ZKEW 2,50 3,60 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ⅜ (9,52) 580 527 463
3,5 kW 1) CS-XZ35ZKEW-H CS-XZ35ZKEW CS-Z35ZKEW 3,50 4,50 4x1,5 295 x 870 x 229 / 11 ¼ (6,35) / ⅜ (9,52) 659 600 514
4,2 kW 2)
CS-XZ42ZKEW-H — CS-Z42ZKEW 4,20 5,60 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ½ (12,70) 685 — 551
5,0 kW 3) — CS-XZ50ZKEW CS-Z50ZKEW 5,00 6,80 4x2,5 295 x 1 040 x 244 / 12 ¼ (6,35) / ½ (12,70) — 973 736
7,1 kW — — CS-Z71ZKEW 7,10 8,70 4x2,5 295 x 1 040 x 244 / 13 ¼ (6,35) / ⅝ (15,88) — — 1,125

14
DOMESTIC INDEX DOMESTIC

Compatible indoor units for multi combinations

Optional wired
remote controller.
CZ-RD517C
Built-in

Wall-mounted TZ Indoor unit Nominal capacity Connection in. / out. Dimension / Net weight Piping diameter RRP
super-compact
Cooling Heating HxWxD Liquid / Gas
kW kW mm² mm / kg Inch (mm) £
1,6 kW CS-MTZ16ZKE 1,60 2,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 347
2,0 kW CS-TZ20ZKEW 2,00 3,20 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 385
2,5 kW CS-TZ25ZKEW 2,50 3,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 429
3,5 kW 1) CS-TZ35ZKEW 3,50 4,50 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 475
4,2 kW CS-TZ42ZKEW 4,20 5,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ½ (12,70) 542
5,0 kW CS-TZ50ZKEW 5,00 6,80 4x2,5 290 x 779 x 209 / 8 ¼ (6,35) / ½ (12,70) 592
6,0 kW CS-TZ60ZKEW 6,00 8,50 4x2,5 295 x 1 040 x 244 / 12 ¼ (6,35) / ½ (12,70) 846
7,1 kW CS-TZ71ZKEW 7,10 8,70 4x2,5 295 x 1 040 x 244 / 13 ¼ (6,35) / ⅝ (15,88) 1,000

Optional wired
remote controller.
CZ-RD517C
Optional

Floor console 4) Indoor unit Nominal capacity Connection in. / out. Dimension / Net weight Piping diameter RRP
Cooling Heating HxWxD Liquid / Gas
kW kW mm² mm / kg Inch (mm) £
2,0 kW CS-MZ20UFEA 2,00 3,20 4x1,5 600 x 750 x 207 / 13 ¼ (6,35) / ⅜ (9,52) 774
2,5 kW CS-Z25UFEAW 2,50 3,60 4x1,5 600 x 750 x 207 / 13 ¼ (6,35) / ⅜ (9,52) 964
3,5 kW 1)
CS-Z35UFEAW 3,50 4,50 4x1,5 600 x 750 x 207 / 13 ¼ (6,35) / ⅜ (9,52) 1,046
5,0 kW CS-Z50UFEAW 5,00 5,30 4x1,5 600 x 750 x 207 / 13 ¼ (6,35) / ½ (12,70) 1,236

Optional wired Optional wired Panel (sold separately).


remote controller. remote controller. CZ-KPY4
CZ-RTC6W CZ-RTC6
Optional

4 way 60x60 Indoor unit Nominal capacity Connection in. / Dimension / Net weight Piping diameter RRP
cassette* (Panel CZ-KPY4) out.
Cooling Heating Indoor H x W x D Panel H x W x D Liquid / Gas Indoor Panel
kW kW mm² mm / kg mm / kg Inch (mm) £ £
2,0 kW S-M20PY3E 2,00 3,20 4x1,5 243 x 575 x 575 / 15 30 x 625 x 625 / 2,8 ¼ (6,35) / ½ (12,70) 657 266
2,5 kW S-25PY3E 2,50 3,60 4x1,5 243 x 575 x 575 / 15 30 x 625 x 625 / 2,8 ¼ (6,35) / ½ (12,70) 738 266
3,5 kW 1) S-36PY3E 3,50 3,60 4x1,5 243 x 575 x 575 / 15 30 x 625 x 625 / 2,8 ¼ (6,35) / ½ (12,70) 782 266
5,0 kW 3) S-50PY3E 5,00 6,80 4x1,5 243 x 575 x 575 / 15 30 x 625 x 625 / 2,8 ¼ (6,35) / ½ (12,70) 887 266
6,0 kW S-60PY3E 6,00 8,50 4x1,5 243 x 575 x 575 / 15 30 x 625 x 625 / 2,8 ⅜ (9,52) / ⅝ (15,88) 1,083 266

* Compatible with Commercial control and connectivity accessories only. For detailed information go to the control systems section.

Optional wireless
control kit.
CZ-RL511D
Optional

Low static Indoor unit Nominal capacity Connection in. / out. Dimension / Net weight Piping diameter RRP
pressure
hide-away Cooling Heating HxWxD Liquid / Gas
kW kW mm² mm / kg Inch (mm) £
2,0 kW CS-MZ20UD3EA 2,00 3,20 4x1,5 200 x 750 x 640 / 19 ¼ (6,35) / ⅜ (9,52) 719
2,5 kW CS-Z25UD3EAW 2,50 3,60 4x1,5 200 x 750 x 640 / 19 ¼ (6,35) / ⅜ (9,52) 867
3,5 kW 1) CS-Z35UD3EAW 3,50 4,50 4x1,5 200 x 750 x 640 / 19 ¼ (6,35) / ⅜ (9,52) 907
5,0 kW 3) CS-Z50UD3EAW 5,00 6,80 4x1,5 200 x 750 x 640 / 19 ¼ (6,35) / ½ (12,70) 1,206
6,0 kW CS-Z60UD3EAW 6,00 8,50 4x1,5 200 x 750 x 640 / 19 ¼ (6,35) / ½ (12,70) 1,258

1) Heating capacity in combination with Free Multi outdoor units except with CU-2Z35TBE. In this case, the heating capacity is 4,20 kW. 3) Heating capacity in combination with Free Multi outdoor units except with
CU-2Z50TBE. In this case, the heating capacity is 5,00 kW. 3) Heating capacity in combination with Free Multi outdoor units except with CU-2Z35TBE. In this case, the heating capacity is 5,30 kW. 4) Compatible only
with 2 ports R32 outdoor CU-2Z35TBE / CU-2Z41TBE / CU-2Z50TBE. Minimum quantity of connection: 2 indoor units.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
15
GENERAL INDEX

New Power Heat Multi system


Outdoor units Power Heat Multi system · R32
New 2025
Operation range down to -25 °C.
Equipped with base pan heater.
High energy efficiency: SCOP of 4,60.
TENTATIVE DATA
Outdoor unit Nominal capacity SEER SCOP Dimension 1) Weight RRP
Cooling Heating HxWxD
kW kW A+++ to D A+++ to D mm kg £
4,00 ~8.50 kW CU-2Z50ABEC 5,30 6,40 8,00 A++ 4,40 A++ 795 x 875 x 320 58 2,332
1ph
4,50 ~11,00 kW CU-3Z75ABEC 7,50 8,60 8,00 A++ 4,60 A++ 795 x 875 x 320 62 3,192

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 4,00 ~8.50 4,50 ~11,00 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ Outdoor unit kW 4,00 ~8.50 4,50 ~11,00
Pipe length range total m 50 60 Recommended fuse A 20 20
Pipe length range to one unit m 3 ~ 25 3 ~ 25 Recommended power
mm² 3 x 2.5 3 x 2.5
Elevation difference (in / out) m 15 15 cable section

Pre-charged pipe length m 30 30 Connection in. / out. mm² 4 x 1.5 4 x 1.5


Additional gas amount g/m 20 20

1) Add 70 or 95 mm for piping port.

Possible outdoor / indoor units combinations


Rooms Outdoor unit Indoor capacity Wall-mounted Etherea
connected (Min - Max)
20 25 35 50
2 CU-2Z50ABEC 4,00 ~8.50 kW • • • •
3 CU-3Z75ABEC 4,50 ~11.00 kW • • • •

Optional wired
remote controller.
CZ-RD517C
Built-in

Wall-mounted Indoor unit Indoor unit Indoor unit Nominal capacity Connection Dimension / Net weight Piping diameter RRP
Etherea graphite grey silver matt white in. / out.
Cooling Heating HxWxD Liquid / Gas Grey Silver White
kW kW mm² mm / kg Inch (mm) £ £ £
2,0 kW CS-XZ20ZKEW-H CS-XZ20ZKEW CS-Z20ZKEW 2,00 3,20 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ⅜ (9,52) 479 435 380
2,5 kW CS-XZ25ZKEW-H CS-XZ25ZKEW CS-Z25ZKEW 2,50 3,60 4x1,5 295 x 870 x 229 / 10 ¼ (6,35) / ⅜ (9,52) 580 527 463
3,5 kW CS-XZ35ZKEW-H CS-XZ35ZKEW CS-Z35ZKEW 3,50 4,50 4x1,5 295 x 870 x 229 / 11 ¼ (6,35) / ⅜ (9,52) 659 600 514
5,0 kW — CS-XZ50ZKEW CS-Z50ZKEW 5,00 6,80 4x2,5 295 x 1 040 x 244 / 12 ¼ (6,35) / ½ (12,70) — 973 736

New Power Heat Multi system. Reliable heating for the coldest winters.

Powerful heating and cleaner indoor air from -25


a single outdoor unit. The multi split system °C
engineered for cold climates. Reliable heating Equipped with base Compatible with
Powerful heating of two or three rooms with one outdoor even at -25 °C. pan heater. Etherea indoor units,
with nanoe™ X.
unit, even at -25 °C low outdoor temperatures.
The multi split solution offers high flexibility, as 2 to 3
Reduces the burden of aesthetics, installation and maintenance.
indoor units can be connected to a single outdoor unit.

Check out the installation of the


Power Heat Multi system at the Arctic Seamless Reduced Excellent
Treehouse Hotel in Lapland, Finland. integration of installation time. maintainability.
outdoor unit.

16
DOMESTIC INDEX DOMESTIC

Multi wall TZ
Outdoor units Multi TZ · R32
Up to 3 indoor units with a single outdoor unit.
High energy efficiency class A++ SEER.
Operation range down to -15 °C in heating.

Outdoor unit Nominal capacity SEER SCOP Dimension 1) Weight RRP


Cooling Heating HxWxD
kW kW A+++ to D A+++ to D mm kg £
3,2 ~ 6,0 kW CU-2TZ41TBE 4,10 4,40 7,10 A++ 4,30 A+ 542 x 780 x 289 35 1,292
1ph 3,2 ~ 7,7 kW CU-2TZ50TBE 5,00 5,70 7,00 A++ 4,20 A+ 542 x 780 x 289 35 1,468
4,5 ~ 9,5 kW CU-3TZ52TBE 5,20 6,80 7,60 A++ 4,20 A+ 795 x 875 x 320 71 1,769

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 3,2 ~ 6,0 3,2 ~ 7,7 4,5 ~ 9,5 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-⅜ Outdoor unit kW 3,2 ~ 6,0 3,2 ~ 7,7 4,5 ~ 9,5
Pipe length range total m 6 ~ 30 6 ~ 30 6 ~ 50 Recommended fuse A 16 16 16
Pipe length range to one unit m 3 ~ 20 3 ~ 20 3 ~ 25 Recommended power
mm² 2,5 2,5 2,5
Elevation difference (in / out) m 10 10 15 cable section

Pre-charged pipe length m 20 20 30 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5
Additional gas amount g/m 15 15 20

1) Add 70 or 95 mm for piping port.

Possible outdoor / indoor units combinations


Rooms Outdoor unit Indoor capacity Wall-mounted TZ super-compact
connected (Min - Max)
16 20 25 35 42 50
CU-2TZ41TBE 3,2 ~ 6,0 kW • • • •
2
CU-2TZ50TBE 3,2 ~ 7,7 kW • • • • • •
3 CU-3TZ52TBE 4,5 ~ 9,5 kW • • • • • •
Minimum quantity of connection: 2 indoor units.

Optional wired
remote controller.
CZ-RD517C
Built-in

Wall-mounted TZ Indoor unit Nominal capacity Connection in. / out. Dimension / Net weight Piping diameter RRP
super-compact
Cooling Heating HxWxD Liquid / Gas
kW kW mm² mm / kg Inch (mm) £
1,6 kW CS-MTZ16ZKE 1,60 2,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 333
2,0 kW CS-TZ20ZKEW 2,00 3,20 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 385
2,5 kW CS-TZ25ZKEW 2,50 3,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 429
3,5 kW CS-TZ35ZKEW 3,50 4,50 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ⅜ (9,52) 475
4,2 kW CS-TZ42ZKEW 4,20 5,60 4x1,5 290 x 779 x 209 / 8 ¼ (6,35) / ½ (12,70) 542
5,0 kW CS-TZ50ZKEW 5,00 6,80 4x2,5 290 x 779 x 209 / 8 ¼ (6,35) / ½ (12,70) 592

Order our full RAC range online at


www.panasonic-hvac-direct.co.uk

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
17
GENERAL INDEX

New RAC Solo


RAC Solo · R290 / R32
New 2025 R290
R32
Slim and compact, only 165 mm deep.
No outdoor unit.
Heating and cooling or cooling only modes available.
Built-in
Wi-Fi control via the Aquarea Home app.
Kit matt white RRP
Nominal capacity EER COP Air flow External air flow Dimension Weight
Cooling Heating Average Average HxWxD
kW kW A+++ to D A+++ to D m³/min m³/min mm kg £
1,7 kW P-MOG16IC5-E 1,73 1,71 3,01 - A 3,15 - A 5,0 6,0 549 x 810 x 165 38 2,780
2,0 kW P-MOZ20IC5-E 2,09 2,08 3,29 - A+ 3,31 - A+ 5,2 6,3 549 x 1 010 x 165 41 2,780
1ph
2,5 kW P-MOZ25IC5-E 2,33 2,31 3,25 - A+ 3,28 - A+ 5,3 6,5 549 x 1 010 x 165 41 2,947
3,0 kW P-MOZ30IC5-E 2,87 2,75 2,74 - A 3,12 - A 5,8 7,7 549 x 1 010 x 165 41 3,225

1) Energy Label Scale from A+++ to D.

Order our full RAC range online at


www.panasonic-hvac-direct.co.uk

Domestic AirCon Quick Selector.


This easy-to-use online tool for our range of
domestic products allows you to select the most
suitable split or multi-split system for the needs
of each project and obtain the specifications for
that particular application.

Configure your multi split system in a


few steps using our online tool and see
all possible combinations.

AR Heat Pump Viewer.


Want to show your customer how a Panasonic air
conditioner will look in a particular room?
This is possible with Panasonic's augmented
reality tool, the AR Heat Pump Viewer.

18
DOMESTIC INDEX ACCESSORIES AND CONTROL

Connectivity RRP £ Panel RRP £

Wi-Fi adapter for smart control via CZ-TACG1 136 Panel for 4 way 60x60 cassette - PY3. CZ-KPY4 266
Panasonic Comfort Cloud App.

RAC interface adapter for integration CZ-CAPRA1 194


into S-Link, plus external input and RAC Solo accessories RRP £
alarm/status output.
KNX interface. Can be used with all PAW-AC-KNX-1i 421 Kit of external aluminium grilles with PCZ-GB0738 105
models which have a CN-CNT fixed fins (162 mm holes).
connector (Intesis).
Kit of external aluminium grilles with PCZ-GB1091 135
Modbus interface. Can be used with PAW-AC-MBS-1 421 fixed fins (202 mm holes).
all models which have a CN-CNT
Insect protection kit (1 metal mesh, 1 PCZ-GB0755 93
connector (Intesis).
grille in metal wire and fixing
BACnet interface. Can be used with all PAW-AC-BAC-1 629 accessories).
models which have a CN-CNT
Side exit formwork for corner PCZ-L00773 1,187
connector (Intesis).
installation (right-hand outlet).
KNX interface. Can be used with all PAW-AZAC-KNX-1 358 Side exit formwork for corner PCZ-L00774 1,187
models which have a CN-CNT installation (left-hand outlet).
connector (Airzone).
Bottom cover kit for overhead PCZ-GB0737 93
Modbus interface. Can be used with PAW-AZAC-MBS-1 358 installation for P-MOZ20/25/30IC5-E.
all models which have a CN-CNT
connector (Airzone). Bottom cover kit for overhead PCZ-GB1105 93
installation for P-MOG16IC5-E.
BACnet interface. Can be used with all PAW-AZAC-BAC-1 592
models which have a CN-CNT Condensate drain pipe heater kit*. PCZ-GB1119 62
connector (Airzone). * Check availability.
This interface can be used with all PAW-AC-DIO 212
models which have a CN-RMT
connector.

Individual controls RRP £

Wired remote controller for wall- CZ-RD517C 172


mounted and floor console.

Infrared Sky Remote controller for CZ-RL511D 126


hideaway with 2 m infrared receiver
cable.
CONEX wired remote controller (non- CZ-RTC6W 172
wireless) for 4 way 60x60 cassette -
PY3, white.
CONEX wired remote controller (non- CZ-RTC6 172
wireless) for 4 way 60x60 cassette -
PY3, black.

19
GENERAL INDEX

Panasonic Commercial
air to air
Panasonic has developed an impressive range
of highly efficient Commercial Air Conditioners.
This range confirms our commitment to the
environment, with our highly efficient Inverter
compressor technology to optimise performance.

20
COMMERCIAL

New 2025

Jet Air Stream.


· High air distribution for large spaces, with an air volume of up to 5 000 m³/h
· Optimal comfort with Smart Jet – self-directing nozzles
· Three versions available: Smart Jet (self-directing nozzles), Manual nozzles, and Ducted connection

Enhanced flexibility with the upgraded PACi NX indoor unit line-up.


· Wall-mounted PK4: New flat design with stylish matt white finish featuring improved serviceability and nanoe™ X
(Generator Mark 3) for better indoor air quality
· 4 way 90x90 cassette PU3: New graphite black and white panels providing options to suit a variety of light commercial
applications

BION air pollutant filter.


IAQ solution filtering certain types of pollutants, such as nitrogen dioxide (NO2), nitrogen oxides (NOX) and ozone (O3).
Designed for the adaptive ducted unit - PF3.

PACi NX Elite Series for top-tier commercial air conditioning (3,6 - 25,0 kW).
· 3 wire power and communication for absolute ease of refurbishment
· Highly efficient performance SEER: 8,9 A+++ / SCOP: 5,1 A+++ at 3,6 kW (in 90x90 cassette)
· A compact outdoor unit featuring a single fan across all the capacities
· Long piping allowance, maximum 100 m 1)
· Wide operation range, up to 52 °C in cooling and down to -20 °C in heating
· Big PACi NX range (20,0-25,0 kW): Available with Water Heat Exchanger for chilled and hot water production, offering high
energy efficiency rated A+++ (scale: A+++ to D)
1) For models 10,0 ~ 25,0 kW.

PACi NX Standard Series for economy and value (2,5 - 14,0 kW).
· 3 wire power and communication for absolute ease of refurbishment
· Top class SEER / SCOP in the standard Inverter category SEER: 8,1 A++ / SCOP: 4,8 A++ at 3,6 kW (in 90x90 cassette)
· Low-height single fan outdoor unit design
· Operation range, up to 43 °C in cooling and down to -15 °C in heating

The complete line-up of air to air indoor units with nanoe™ X as a standard.
Better indoor air quality with nanoe™ X.
· nanoe™ X is a filter free solution that does not require maintenance
· 99,9% SARS-CoV-2 inhibition within 2 hours 1)
1) Novel coronavirus (SARS-CoV-2), [Test organization] Texcell (France) [Test subject] Adhered novel coronavirus (SARS-CoV-2) [Test volume] 45 L enclosed box [Test result] Inhibited 99,9% in 2 hours [Test report]
1140-01 A1.

Water Heat Exchanger for chilled and hot water production.


· Water outlet temperature in cooling from 5 to 15 °C, in heating from 30 to 55 °C
· Constant 55 °C flow available
· A+++ energy efficiency class (scale: A+++ to D)
· Flexible and space saving system

CONEX. Devices and apps.


· Intuitive control with a stylish design; available in white and black colours
· Apps available for daily remote control operation via Bluetooth® 1) or Wi-Fi 2)
· Panasonic H&C Diagnosis App for professionals 1)
1) Panasonic H&C Control App and Panasonic H&C Diagnosis App.
2) Panasonic Comfort Cloud App.

YKEA-1 server room solution.


Perfect solution for smaller server rooms.
· Designed for 24/7 operation
· Operation down to -25 °C ambient
· Aerowings 2.0 technology for enhanced airflow distribution
· High seasonal performance

21
GENERAL INDEX

Commercial units range


Page Indoor units 2,5 kW 3,6 kW 4,5 kW 1) 5,0 kW 6,0 kW

Wall-mounted
P. 24
Professional · R32 2)
CS-Z25YKEA-1 CS-Z35YKEA-1 CS-Z42YKEA-1 CS-Z50YKEA-1

NEW PACi NX
P. 24
wall-mounted · R32
S-2545PK4E S-2545PK4E S-2545PK4E S-5010PK4E S-5010PK4E

PACi NX 4 way
P. 25 60x60 cassette
· R32
S-25PY3E S-36PY3E S-50PY3E S-60PY3E

PACi NX 4 way
P. 26 90x90 cassette
· R32
S-3650PU3E S-3650PU3E S-3650PU3E S-6071PU3E

PACi NX ceiling
P. 27
· R32
S-3650PT3E S-3650PT3E S-3650PT3E S-6071PT3E

PACi NX adaptive
P. 28
ducted · R32
S-3650PF3E S-3650PF3E S-3650PF3E S-6071PF3E

Big PACi NX high


static pressure
P. 29
hide-away 20-25 kW
· R32

NEW PACi NX
P. 30 Jet Air Stream
· R32

Outdoor units 2,5 kW 3,6 kW 5,0 kW 6,0 kW

PACi NX Elite · R32


Big PACi NX
(20,0-25,0 kW) · R32

U-36PZH3E5 U-50PZH3E5 U-60PZH3E5

PACi NX Standard · R32

U-25PZ3E5 U-36PZ3E5 U-50PZ3E5 U-60PZ3E5A

1) The 4,5 kW indoor capacity options are only available only for twin, triple and double-twin combinations. 2) Not compatible with PACi NX outdoors and accessories. Domestic range sales conditions may apply.
Check with your sales representative.
* U-__E5 Single phase / U-__E8 Three phase.

22
COMMERCIAL INDEX COMMERCIAL

OPTIONAL UNITS ON VENTILATION SECTION

7,1 kW 10,0 kW 12,5 kW 14,0 kW 20,0 kW 25,0 kW

CS-Z71YKEA-1

S-5010PK4E S-5010PK4E

A new panel in graphite black (RAL9011) is available.

S-6071PU3E S-1014PU3E S-1014PU3E S-1014PU3E

S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E

S-6071PF3E S-1014PF3E S-1014PF3E S-1014PF3E

S-200PE4E S-250PE4E

P-VTVF140MC5-PE / P-VTVF250MC5-PE /
P-VTVF140NC5-PE / P-VTVF250NC5-PE /
P-VTVF140PC5-PE P-VTVF250PC5-PE

7,1 kW 10,0 kW 12,5 kW 14,0 kW 20,0 kW 25,0 kW

U-71PZH4E5 / U-71PZH4E8 U-100PZH4E5 / U-100PZH4E8 U-125PZH4E5 / U-125PZH4E8 U-140PZH4E5 / U-140PZH4E8 U-200PZH4E8 U-250PZH4E8

U-71PZ3E5A U-100PZ3E5 / U-100PZ3E8 U-125PZ3E5 / U-125PZ3E8 U-140PZ3E5 / U-140PZ3E8

23
GENERAL INDEX

Wall-mounted Professional
Wall-mounted Professional -25 °C · R32
Designed for 24h/7d a week operation for server rooms.
High seasonal performance.
Operation range up to 43 °C in cooling and down to -15 °C in heating.

Kit (remote controller included) Indoor unit Outdoor unit RRP


Nominal capacity SEER 1) SCOP 1) Dimension Weight Dimension 2) Weight
Cooling Heating HxWxD HxWxD
kW kW mm kg mm kg £
2,5 kW KIT-Z25-YKEA-1 2,50 3,40 9,5 A+++ 4,6 A++ CS-Z25YKEA-1 295 x 870 x 229 11 CU-Z25YKEA-1 542 x 780 x 289 30 1,330
3,5 kW KIT-Z35-YKEA-1 3,50 4,00 9,6 A+++ 4,6 A++ CS-Z35YKEA-1 295 x 870 x 229 11 CU-Z35YKEA-1 542 x 780 x 289 30 1,524
1ph 4,2 kW KIT-Z42-YKEA-1 4,20 5,30 8,6 A+++ 4,5 A+ CS-Z42YKEA-1 295 x 870 x 229 11 CU-Z42YKEA-1 542 x 780 x 289 30 1,824
5,0 kW KIT-Z50-YKEA-1 5,00 5,80 8,6 A+++ 4,6 A++ CS-Z50YKEA-1 295 x 1 040 x 244 12 CU-Z50YKEA-1 695 x 875 x 320 40 1,924
7,1 kW KIT-Z71-YKEA-1 7,10 8,20 6,5 A++ 4,1 A+ CS-Z71YKEA-1 295 x 1 040 x 244 13 CU-Z71YKEA-1 695 x 875 x 320 45 2,604

Piping information Electrical information (power supply to indoor)


Kit kW 2,5 3,5 4,2 5,0 7,1 Single phase
Piping diameter (liquid - gas) Inch ¼-⅜ ¼-⅜ ¼-½ ¼-½ ¼-⅝ Kit kW 2,5 3,5 4,2 5,0 7,1
Pipe length range m 3 ~ 20 3 ~ 20 3 ~ 20 3 ~ 30 3 ~ 30 Recommended fuse A 16 16 16 16 20
Elevation difference (in / out) m 15 15 15 15 20 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 7,5 7,5 10
Additional gas amount g/m 10 10 10 15 25

1) Energy Label Scale from A+++ to D. 2) Add 70 mm for piping port. * Not compatible with PACi NX outdoors and accessories. Domestic range sales conditions may apply. Check with your sales representative.

PACi NX Series
NEW PACi NX Series Elite wall-mounted - PK4 · R32
Modern, flat design with a stylish matte white finish featuring
nanoe™ X (Generator Mark 3). New 2025
Improved fan serviceability.
Operation range up to 52 °C 1) in cooling and down to -20 °C in heating.
Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER 2) SCOP 2) Dimension Weight Dimension Weight
Cooling Heating HxWxD HxWxD
kW kW mm kg mm kg £
3,6 kW KIT-36PK4ZH5 3,5 4,0 7,7 A++ 4,7 A++ S-2545PK4E 290 x 765 x 214 9 U-36PZH3E5 695 x 875 x 320 42 2,344
5,0 kW KIT-50PK4ZH5 5,0 5,6 8,0 A++ 4,6 A++ S-5010PK4E 295 x 1 060 x 249 14 U-50PZH3E5 695 x 875 x 320 42 2,863
1ph 6,0 kW KIT-60PK4ZH5 6,1 7,0 7,1 A++ 4,7 A++ S-5010PK4E 295 x 1 060 x 249 14 U-60PZH3E5 695 x 875 x 320 43 3,030
7,1 kW KIT-71PK4ZH45 7,1 7,8 6,6 A++ 4,6 A++ S-5010PK4E 295 x 1 060 x 249 14 U-71PZH4E5 996 x 980 x 370 66 2,801
10,0 kW KIT-100PK4ZH45 9,5 9,5 6,6 A++ 4,1 A+ S-5010PK4E 295 x 1 060 x 249 14 U-100PZH4E5 996 x 980 x 370 84 3,130
7,1 kW KIT-71PK4ZH48 7,1 7,8 6,6 A++ 4,6 A++ S-5010PK4E 295 x 1 060 x 249 14 U-71PZH4E8 996 x 980 x 370 66 3,620
3ph
10,0 kW KIT-100PK4ZH48 9,5 9,5 6,6 A++ 4,1 A+ S-5010PK4E 295 x 1 060 x 249 14 U-100PZH4E8 996 x 980 x 370 82 4,181

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 7,1 10,0
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 Recommended fuse A 20 20 25 25 35 16 16
Elevation difference (in / out) 3)
m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5 4x2,5 4x2,5 4x2,5 4x2,5
Pre-charged pipe length m 30 30 30 30 30
Additional gas amount 4) g/m 15 15 15 30 40

1) For models U-***PZH4E5(8). 2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Outdoor unit located lower / outdoor unit located higher. 4) Please refer to the technical manual for the required refrigerant amount for multi-indoor systems.

Order our full PACi range online at


www.panasonic-hvac-direct.co.uk

24
COMMERCIAL INDEX COMMERCIAL

PACi NX Series
NEW PACi NX Series Standard wall-mounted - PK4 · R32
Modern, flat design with a stylish matte white finish featuring
nanoe™ X (Generator Mark 3). New 2025
Improved fan serviceability.
Operation range up to 43 °C in cooling and down to -15 °C in heating.
Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER 1) SCOP 1) Dimension Weight Dimension Weight
Cooling Heating HxWxD HxWxD
kW kW mm kg mm kg £
2,5 kW KIT-25PK4Z5 2,5 2,8 6,6 A++ 4,2 A+ S-2545PK4E 290 x 765 x 214 9 U-25PZ3E5 619 x 824 x 299 32 1,879
3,6 kW KIT-36PK4Z5 3,5 3,6 6,8 A++ 4,4 A+ S-2545PK4E 290 x 765 x 214 9 U-36PZ3E5 619 x 824 x 299 32 1,940
5,0 kW KIT-50PK4Z5 5,0 5,0 7,2 A++ 4,4 A+ S-5010PK4E 295 x 1 060 x 249 14 U-50PZ3E5 619 x 824 x 299 35 2,501
1ph
6,0 kW KIT-60PK4Z5 6,1 6,1 7,0 A++ 4,6 A++ S-5010PK4E 295 x 1 060 x 249 14 U-60PZ3E5A 695 x 875 x 320 42 2,513
7,1 kW KIT-71PK4Z5 6,9 7,1 6,0 A+ 4,4 A+ S-5010PK4E 295 x 1 060 x 249 14 U-71PZ3E5A 695 x 875 x 320 50 2,861
10,0 kW KIT-100PK4Z5 9,0 9,0 6,2 A++ 4,0 A+ S-5010PK4E 295 x 1 060 x 249 14 U-100PZ3E5 996 x 980 x 370 83 3,203
3ph 10,0 kW KIT-100PK4Z8 9,0 9,0 6,2 A++ 4,0 A+ S-5010PK4E 295 x 1 060 x 249 14 U-100PZ3E8 996 x 980 x 370 83 3,318

Piping information Electrical information (power supply to outdoor)


Kit kW 2,5 3,6 5,0 6,0 7,1 10,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-⅝ ⅜-⅝ Kit kW 2,5 3,6 5,0 6,0 7,1 10,0 10,0
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 Recommended fuse A 16 20 20 25 25 35 16
Elevation difference (in / out) 2) m 15 / 15 15 / 15 15 / 15 15 / 30 20 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5 4x1,5 4x2,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 7,5 30 30 30
Additional gas amount g/m 10 10 15 15 17 45

1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825.
2) Outdoor unit located lower / outdoor unit located higher.

PACi NX Series Elite and Standard 4 way 60x60 cassette - PY3 · R32
nanoe™ X (Generator Mark 2).
Panel CZ-KPY4 (H x W x D / net weight): 30 x 625 x 625 mm / 2,8 kg, Panel.
CZ-KPY4
white colour, RAL9010.

Kit (CZ-RTC5B remote controller £172 and CZ-KPY4 panel £266 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER 1) SCOP 1) Dimension / Weight Dimension / Weight
Cool UK Heat UK HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
Standard
2.5 kW KIT-25PY3Z5 2.5 2.4 / 1.6 3.2 4.0 6.5 A++ 4.6 A++ S-25PY3E 243 x 575 x 575 / 15 U-25PZ3E5 619 x 824 x 299 / 32 2,016
3.6 kW KIT-36PY3Z5 3.6 3.4 / 2.3 3.6 4.0 6.7 A++ 4.3 A+ S-36PY3E 243 x 575 x 575 / 15 U-36PZ3E5 619 x 824 x 299 / 32 2,121
1ph
5.0 kW KIT-50PY3Z5 5.0 4.8 / 3.0 5.0 5.6 7.3 A++ 4.4 A+ S-50PY3E 243 x 575 x 575 / 15 U-50PZ3E5 619 x 824 x 299 / 35 2,492
6.0 kW KIT-60PY3Z5 6.0 5.9 / 3.7 6.0 6.3 6.8 A++ 4.2 A+ S-60PY3E 243 x 575 x 575 / 15 U-60PZ3E5A 695 x 875 x 320 / 46 2,700
Elite
3.6 kW KIT-36PY3ZH5 3.6 3.5 / 2.3 4.0 4.5 7.3 A++ 4.7 A++ S-36PY3E 243 x 575 x 575 / 15 U-36PZH3E5 695 x 875 x 320 / 42 2,525
1ph 5.0 kW KIT-50PY3ZH5 5.0 4.9 / 3.1 5.6 5.8 7.0 A++ 4.6 A++ S-50PY3E 243 x 575 x 575 / 15 U-50PZH3E5 695 x 875 x 320 / 42 2,854
6.0 kW KIT-60PY3ZH5 6.0 5.9 / 3.7 7.0 6.7 6.7 A++ 4.3 A+ S-60PY3E 243 x 575 x 575 / 15 U-60PZH3E5 695 x 875 x 320 / 43 3,217

Piping information Electrical information (power supply to outdoor)


Elite Standard Single phase
Kit kW 3,6 5,0 6,0 2,5 3,6 5,0 6,0 Kit kW 2,5 3,6 5,0 6,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ Recommended fuse A 16 16 16 20
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 40 Connection in. / out. mm² 4x1,5 4x1,5 4x1,5 4x2,5
Elevation difference (in / out) 2) m 15 / 30 15 / 30 15 / 30 15 / 15 15 / 15 15 / 15 15 / 30
Pre-charged pipe length m 30 30 30 7,5 7,5 7,5 30
Additional gas amount g/m 15 15 15 10 10 15 15

1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825.
2) Outdoor unit located lower / outdoor unit located higher.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
25
GENERAL INDEX

PACi NX Series
PACi NX Series Elite 4 way 90x90 cassette - PU3 · R32
nanoe™ X (Generator Mark 1).
Panel (H x W x D / net weight): 33,5 x 950 x 950 mm / 5 kg.
Advanced Econavi function available (optional panel: CZ-KPU3AW).
Operation range up to 52 °C 1) in cooling and down to -20 °C in heating.
Kit (CZ-RTC5B remote controller £172 and CZ-KPU3W panel £242 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 2) ηs,h 2) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PU3ZH5 3.6 3.5 / 2.6 4.0 4.5 8.9 A+++ 5.1 A+++ S-3650PU3E 256 x 840 x 840 / 19 U-36PZH3E5 695 x 875 x 320 / 42 2,387
5.0 kW KIT-50PU3ZH5 5.0 4.9 / 3.4 5.6 5.9 8.6 A+++ 4.9 A++ S-3650PU3E 256 x 840 x 840 / 19 U-50PZH3E5 695 x 875 x 320 / 42 2,611
6.0 kW KIT-60PU3ZH5 6.0 5.9 / 4.1 7.0 7.2 8.0 A++ 4.8 A++ S-6071PU3E 256 x 840 x 840 / 20 U-60PZH3E5 695 x 875 x 320 / 43 3,121
1ph 7.1 kW KIT-71PU3ZH45 7.1 8.1 / 6.2 8.0 8.3 7.7 A++ 4.8 A++ S-6071PU3E 256 x 840 x 840 / 20 U-71PZH4E5 996 x 980 x 370 / 66 3,648
10.0 kW KIT-100PU3ZH45 10.0 11.2 / 9.1 11.2 12.7 7.8 A++ 4.9 A++ S-1014PU3E 319 x 840 x 840 / 25 U-100PZH4E5 996 x 980 x 370 / 84 4,334
12.5 kW KIT-125PU3ZH45 12.5 12.5 / 9.9 14.0 14.6 304.3% 186.0% S-1014PU3E 319 x 840 x 840 / 25 U-125PZH4E5 996 x 980 x 370 / 86 4,664
14.0 kW KIT-140PU3ZH45 14.0 14.3 / 10.9 16.0 16.4 286.6% 181.2% S-1014PU3E 319 x 840 x 840 / 25 U-140PZH4E5 996 x 980 x 370 / 86 5,124
7.1 kW KIT-71PU3ZH48 7.1 8.1 / 6.2 8.0 8.3 7.6 A++ 4.8 A++ S-6071PU3E 256 x 840 x 840 / 20 U-71PZH4E8 996 x 980 x 370 / 66 3,711
10.0 kW KIT-100PU3ZH48 10.0 11.2 / 9.1 11.2 12.7 7.7 A++ 4.9 A++ S-1014PU3E 319 x 840 x 840 / 25 U-100PZH4E8 996 x 980 x 370 / 82 4,378
3ph
12.5 kW KIT-125PU3ZH48 12.5 12.5 / 9.9 14.0 14.6 303.3% 186.0% S-1014PU3E 319 x 840 x 840 / 25 U-125PZH4E8 996 x 980 x 370 / 84 4,804
14.0 kW KIT-140PU3ZH48 14.0 14.3 / 10.9 16.0 16.4 285.6% 181.1% S-1014PU3E 319 x 840 x 840 / 25 U-140PZH4E8 996 x 980 x 370 / 84 5,500

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 7,1 10,0 12,5 14,0
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5~100 5~100 5~100 Recommended fuse A 20 20 25 25 35 40 40 16 16 16 16
Elevation difference (in / out) 3) m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 30 30 30 30 30 30 30
Additional gas amount g/m 15 15 15 30 404) 404) 404)

1) For models U-***PZH4E5(8). 2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Outdoor unit located lower / outdoor unit located higher. 4) 25g/m over 85 m

PACi NX Series Standard 4 way 90x90 cassette - PU3 · R32


nanoe™ X (Generator Mark 1).
Panel (H x W x D / net weight): 33,5 x 950 x 950 mm / 5 kg.
Advanced Econavi function available (optional panel: CZ-KPU3AW).
Operation range up to 43 °C in cooling and down to -15 °C in heating.
Kit (CZ-RTC5B remote controller £172 and CZ-KPU3W panel £242 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 1) ηs,h 1) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PU3Z5 3.6 3.4 / 2.6 3.6 4.0 8.1 A++ 4.8 A++ S-3650PU3E 256 x 840 x 840 / 19 U-36PZ3E5 619 x 824 x 299 / 32 1,983
5.0 kW KIT-50PU3Z5 5.0 4.8 / 3.3 5.0 5.6 8.0 A++ 4.7 A++ S-3650PU3E 256 x 840 x 840 / 19 U-50PZ3E5 619 x 824 x 299 / 35 2,249
6.0 kW KIT-60PU3Z5 6.0 5.9 / 4.1 6.0 6.3 7.8 A++ 4.9 A++ S-6071PU3E 256 x 840 x 840 / 20 U-60PZ3E5A 695 x 875 x 320 / 42 2,604
1ph 7.1 kW KIT-71PU3Z5 7.1 6.7 / 4.4 7.1 7.1 6.8 A++ 4.6 A++ S-6071PU3E 256 x 840 x 840 / 20 U-71PZ3E5A 695 x 875 x 320 / 50 2,952
10.0 kW KIT-100PU3Z5 10.0 10.7 / 7.6 10.0 13.0 6.8 A++ 4.4 A+ S-1014PU3E 319 x 840 x 840 / 25 U-100PZ3E5 996 x 980 x 370 / 83 3,400
12.5 kW KIT-125PU3Z5 12.5 12.6 / 8.4 12.5 14.7 267.0% 157.0% S-1014PU3E 319 x 840 x 840 / 25 U-125PZ3E5 996 x 980 x 370 / 87 3,761
14.0 kW KIT-140PU3Z5 14.0 13.9 / 9.2 14.0 15.4 257.0% 152.2% S-1014PU3E 319 x 840 x 840 / 25 U-140PZ3E5 996 x 980 x 370 / 87 4,441
10.0 kW KIT-100PU3Z8 10.0 10.7 / 7.6 10.0 13.0 6.7 A++ 4.4 A+ S-1014PU3E 319 x 840 x 840 / 25 U-100PZ3E8 996 x 980 x 370 / 83 3,515
3ph 12.5 kW KIT-125PU3Z8 12.5 12.6 / 8.4 12.5 14.7 265.8% 157.0% S-1014PU3E 319 x 840 x 840 / 25 U-125PZ3E8 996 x 980 x 370 / 87 3,831
14.0 kW KIT-140PU3Z8 14.0 13.9 / 9.2 14.0 15.4 256.2% 152.2% S-1014PU3E 319 x 840 x 840 / 25 U-140PZ3E8 996 x 980 x 370 / 87 4,476

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 Recommended fuse A 16 16 20 20 30 40 40 20 20 20
Elevation difference (in / out) 2) m 15 / 15 15 / 15 15 / 30 20 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 30 30 30 30 30
Additional gas amount g/m 10 15 15 17 45 45 45
1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825.
2) Outdoor unit located lower / outdoor unit located higher.

White and graphite black panels now available for the 4 way 90x90 cassette,
offering versatile options for commercial applications.
Standard panel, white Econavi panel, white Standard panel, graphite
(RAL9003). (RAL9003). black (RAL9011).
CZ-KPU3W CZ-KPU3AW CZ-KPU3B

26
COMMERCIAL INDEX COMMERCIAL

PACi NX Series
PACi NX Series Elite ceiling - PT3 · R32
Large and wide air distribution good for big rooms.
nanoe™ X (Generator Mark 2).
Operation range up to 52 °C 1) in cooling and down to -20 °C in heating.

Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 2) ηs,h 2) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PT3ZH5 3.5 3.4 / 2.5 4.0 4.5 7.7 A++ 4.9 A++ S-3650PT3E 235 x 960 x 690 / 26 U-36PZH3E5 695 x 875 x 320 / 42 2,478
5.0 kW KIT-50PT3ZH5 5.0 4.9 / 3.3 5.6 5.8 7.4 A++ 4.8 A++ S-3650PT3E 235 x 960 x 690 / 26 U-50PZH3E5 695 x 875 x 320 / 42 2,702
6.0 kW KIT-60PT3ZH5 6.0 5.9 / 4.0 7.0 7.2 7.5 A++ 4.8 A++ S-6071PT3E 235 x 1 275 x 690 / 34 U-60PZH3E5 695 x 875 x 320 / 43 3,144
1ph 7.1 kW KIT-71PT3ZH45 6.8 8.1 / 6.0 8.0 8.0 7.3 A++ 4.7 A++ S-6071PT3E 235 x 1 275 x 690 / 34 U-71PZH4E5 996 x 980 x 370 / 66 3,671
10.0 kW KIT-100PT3ZH45 9.5 11.2 / 8.5 11.2 12.3 7.3 A++ 4.5 A+ S-1014PT3E 235 x 1 590 x 690 / 40 U-100PZH4E5 996 x 980 x 370 / 84 4,581
12.5 kW KIT-125PT3ZH45 12.1 12.5 / 9.5 14.0 14.2 278.4% 175.6% S-1014PT3E 235 x 1 590 x 690 / 40 U-125PZH4E5 996 x 980 x 370 / 86 4,911
14.0 kW KIT-140PT3ZH45 13.4 14.3 / 10.3 16.0 15.9 263.3% 169.3% S-1014PT3E 235 x 1 590 x 690 / 40 U-140PZH4E5 996 x 980 x 370 / 86 5,371
7.1 kW KIT-71PT3ZH48 6.8 8.1 / 6.0 8.0 8.0 7.2 A++ 4.7 A++ S-6071PT3E 235 x 1 275 x 690 / 34 U-71PZH4E8 996 x 980 x 370 / 82 3,734
10.0 kW KIT-100PT3ZH48 9.5 11.2 / 8.5 11.2 12.3 7.2 A++ 4.5 A+ S-1014PT3E 235 x 1 590 x 690 / 40 U-100PZH4E8 996 x 980 x 370 / 84 4,625
3ph
12.5 kW KIT-125PT3ZH48 12.1 12.5 / 9.5 14.0 14.2 277.3% 175.6% S-1014PT3E 235 x 1 590 x 690 / 40 U-125PZH4E8 996 x 980 x 370 / 84 5,051
14.0 kW KIT-140PT3ZH48 13.4 14.3 / 10.3 16.0 15.9 262.4% 169.3% S-1014PT3E 235 x 1 590 x 690 / 40 U-140PZH4E8 996 x 980 x 370 / 84 5,747

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 7,1 10,0 12,5 14,0
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5~100 5~100 5~100 Recommended fuse A 20 20 25 25 35 40 40 16 16 16 16
Elevation difference (in / out) 3) m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 30 30 30 30 30 30 30
Additional gas amount g/m 15 15 15 30 404) 404) 404)

1) For models U-***PZH4E5(8). 2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Outdoor unit located lower / outdoor unit located higher. 4) 25g/m over 85 m

PACi NX Series Standard ceiling - PT3 · R32


Large and wide air distribution good for big rooms.
nanoe™ X (Generator Mark 2).
Operation range up to 43 °C in cooling and down to -15 °C in
heating.
Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 1) ηs,h 1) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PT3Z5 3.5 3.3 / 2.4 3.5 4.0 7.2 A++ 4.4 A+ S-3650PT3E 235 x 960 x 690 / 26 U-36PZ3E5 619 x 824 x 299 / 32 2,074
5.0 kW KIT-50PT3Z5 5.0 4.8 / 3.2 5.0 5.6 6.7 A++ 4.1 A+ S-3650PT3E 235 x 960 x 690 / 26 U-50PZ3E5 619 x 824 x 299 / 35 2,340
6.0 kW KIT-60PT3Z5 6.0 5.9 / 4.0 6.0 6.3 7.3 A++ 4.6 A++ S-6071PT3E 235 x 1 275 x 690 / 34 U-60PZ3E5A 695 x 875 x 320 / 42 2,627
1ph 7.1 kW KIT-71PT3Z5 6.8 6.5 / 4.3 6.8 7.1 5.9 A+ 4.3 A+ S-6071PT3E 235 x 1 275 x 690 / 34 U-71PZ3E5A 695 x 875 x 320 / 50 2,975
10.0 kW KIT-100PT3Z5 10.0 10.7 / 7.1 10.0 13.0 6.6 A++ 4.2 A+ S-1014PT3E 235 x 1 590 x 690 / 40 U-100PZ3E5 996 x 980 x 370 / 83 3,647
12.5 kW KIT-125PT3Z5 12.5 12.6 / 8.2 12.5 14.7 241.7% 147.4% S-1014PT3E 235 x 1 590 x 690 / 40 U-125PZ3E5 996 x 980 x 370 / 87 4,008
14.0 kW KIT-140PT3Z5 14.0 13.9 / 8.9 14.0 15.4 228.8% 145.3% S-1014PT3E 235 x 1 590 x 690 / 40 U-140PZ3E5 996 x 980 x 370 / 87 4,688
10.0 kW KIT-100PT3Z8 10.0 10.7 / 7.1 10.0 13.0 6.5 A++ 4.2 A+ S-1014PT3E 235 x 1 590 x 690 / 40 U-100PZ3E8 996 x 980 x 370 / 83 3,762
3ph 12.5 kW KIT-125PT3Z8 12.5 12.6 / 8.2 12.5 14.7 240.9% 147.4% S-1014PT3E 235 x 1 590 x 690 / 40 U-125PZ3E8 996 x 980 x 370 / 87 4,078
14.0 kW KIT-140PT3Z8 14.0 13.9 / 8.9 14.0 15.4 228.1% 145.3% S-1014PT3E 235 x 1 590 x 690 / 40 U-140PZ3E8 996 x 980 x 370 / 87 4,723

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 Recommended fuse A 16 16 20 20 35 40 40 16 16 16
Elevation difference (in / out) 2) m 15 / 15 15 / 15 15 / 30 20 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 30 30 30 30 30
Additional gas amount g/m 10 15 15 17 45 45 45
Order our full PACi range online at
1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For
www.panasonic-hvac-direct.co.uk
models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825. 2) Outdoor unit located lower / outdoor unit located higher.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
27
GENERAL INDEX

PACi NX Series
PACi NX Series Elite adaptive ducted unit - PF3 · R32
2 installation possibilities (horizontal / vertical) with high ESP 150 Pa.
nanoe™ X (Generator Mark 2).
Operation range up to 52 °C 1) in cooling and down to -20 °C in heating.

Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 2) ηs,h 2) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PF3ZH5 3.6 3.5 / 2.4 4.0 4.5 6.8 A++ 4.5 A+ S-3650PF3E 250 x 800 x 730 / 25 U-36PZH3E5 695 x 875 x 320 / 42 2,479
5.0 kW KIT-50PF3ZH5 5.0 4.9 / 3.2 5.6 5.8 6.1 A++ 4.2 A+ S-3650PF3E 250 x 800 x 730 / 25 U-50PZH3E5 695 x 875 x 320 / 42 2,703
6.0 kW KIT-60PF3ZH5 5.7 5.6 / 3.7 7.0 7.2 7.1 A++ 4.4 A+ S-6071PF3E 250 x 1 000 x 730 / 30 U-60PZH3E5 695 x 875 x 320 / 43 3,113
1ph 7.1 kW KIT-71PF3ZH45 6.8 7.1 / 5.5 7.5 8.0 7.1 A++ 4.7 A++ S-6071PF3E 250 x 1 000 x 730 / 30 U-71PZH4E5 996 x 980 x 370 / 66 3,640
10.0 kW KIT-100PF3ZH45 9.5 10.2 / 8.2 10.8 11.9 7.4 A++ 4.3 A+ S-1014PF3E 250 x 1 400 x 730 / 39 U-100PZH4E5 996 x 980 x 370 / 84 4,572
12.5 kW KIT-125PF3ZH45 12.1 12.1 / 9.3 13.5 13.6 281.7% 165.0% S-1014PF3E 250 x 1 400 x 730 / 39 U-125PZH4E5 996 x 980 x 370 / 86 4,902
14.0 kW KIT-140PF3ZH45 13.4 13.7 / 10.1 15.5 15.4 275.9% 162.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-140PZH4E5 996 x 980 x 370 / 86 5,362
7.1 kW KIT-71PF3ZH48 6.8 7.1 / 5.5 7.5 8.0 7.1 A++ 4.7 A++ S-6071PF3E 250 x 1 000 x 730 / 30 U-71PZH4E8 996 x 980 x 370 / 82 3,703
10.0 kW KIT-100PF3ZH48 9.5 10.2 / 8.2 10.8 11.9 7.4 A++ 4.3 A+ S-1014PF3E 250 x 1 400 x 730 / 39 U-100PZH4E8 996 x 980 x 370 / 84 4,616
3ph
12.5 kW KIT-125PF3ZH48 12.1 12.1 / 9.3 13.5 13.6 281.0% 165.0% S-1014PF3E 250 x 1 400 x 730 / 39 U-125PZH4E8 996 x 980 x 370 / 84 5,042
14.0 kW KIT-140PF3ZH48 13.4 13.7 / 10.1 15.5 15.4 275.2% 162.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-140PZH4E8 996 x 980 x 370 / 84 5,738

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 7,1 10,0 12,5 14,0
Pipe length range m 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5~100 5~100 5~100 Recommended fuse A 20 20 25 25 35 40 40 16 16 16 16
Elevation difference (in / out) 3) m 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 30 30 30 30 30 30 30
Additional gas amount g/m 15 15 15 30 404) 404) 404)

1) For models U-***PZH4E5(8). 2) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For models above 12 kW, the ηs,c / ηs,h values is
calculated based on EN 14825. 3) Outdoor unit located lower / outdoor unit located higher. 4) 25g/m over 85 m

PACi NX Series Standard adaptive ducted unit - PF3 · R32


2 installation possibilities (horizontal / vertical) with high ESP
150 Pa. nanoe™ X (Generator Mark 2).
Operation range up to 43 °C in cooling and down to -15 °C in
heating.

Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity SEER / SCOP / Dimension / Weight Dimension / Weight
Cool UK Heat UK ηs,c 1) ηs,h 1) HxWxD HxWxD
Total / Total
Sensible

kW kW kW kW mm / kg mm / kg £
3.6 kW KIT-36PF3Z5 3.4 3.2 / 2.3 3.4 4.0 6.0 A+ 4.0 A+ S-3650PF3E 250 x 800 x 730 / 25 U-36PZ3E5 619 x 824 x 299 / 32 2,075
5.0 kW KIT-50PF3Z5 5.0 4.8 / 3.1 5.0 5.2 6.5 A++ 4.0 A+ S-3650PF3E 250 x 800 x 730 / 25 U-50PZ3E5 619 x 824 x 299 / 35 2,341
6.0 kW KIT-60PF3Z5 5.7 5.6 / 3.7 5.7 6.3 6.4 A++ 4.4 A+ S-6071PF3E 250 x 1 000 x 730 / 30 U-60PZ3E5A 695 x 875 x 320 / 42 2,596
1ph 7.1 kW KIT-71PF3Z5 6.8 6.5 / 4.2 6.8 7.1 6.0 A+ 4.1 A+ S-6071PF3E 250 x 1 000 x 730 / 30 U-71PZ3E5A 695 x 875 x 320 / 50 2,944
10.0 kW KIT-100PF3Z5 9.5 10.6 / 7.3 9.5 12.5 6.6 A++ 3.9 A S-1014PF3E 250 x 1 400 x 730 / 39 U-100PZ3E5 996 x 980 x 370 / 83 3,638
12.5 kW KIT-125PF3Z5 12.1 12.6 / 8.2 12.1 14.7 257.4% 142.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-125PZ3E5 996 x 980 x 370 / 87 3,999
14.0 kW KIT-140PF3Z5 13.4 13.9 / 9.0 13.4 15.4 252.2% 140.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-140PZ3E5 996 x 980 x 370 / 87 4,679
10.0 kW KIT-100PF3Z8 9.5 10.6 / 7.3 9.5 12.5 6.5 A++ 3.9 A S-1014PF3E 250 x 1 400 x 730 / 39 U-100PZ3E8 996 x 980 x 370 / 83 3,753
3ph 12.5 kW KIT-125PF3Z8 12.1 12.6 / 8.2 12.1 14.7 256.2% 142.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-125PZ3E8 996 x 980 x 370 / 87 4,069
14.0 kW KIT-140PF3Z8 13.4 13.9 / 9.0 13.4 15.4 251.4% 140.6% S-1014PF3E 250 x 1 400 x 730 / 39 U-140PZ3E8 996 x 980 x 370 / 87 4,714

Piping information Electrical information (power supply to outdoor)


Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ Kit kW 3,6 5,0 6,0 7,1 10,0 12,5 14,0 10,0 12,5 14,0
Pipe length range m 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 Recommended fuse A 16 16 20 20 35 40 40 16 20 20
Elevation difference (in / out) 2) m 15 / 15 15 / 15 15 / 30 20 / 30 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x1,5 4x2,5 4x2,5
Pre-charged pipe length m 7,5 7,5 30 30 30 30 30
Additional gas amount g/m 10 15 15 17 45 45 45

Order our full PACi range online at


1) Energy Label Scale from A+++ to D. For models below 12 kW, the SEER and SCOP is calculated based on values of EU/626/2011. For
models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825. 2) Outdoor unit located lower / outdoor unit located higher. www.panasonic-hvac-direct.co.uk

28
COMMERCIAL INDEX COMMERCIAL

PACi NX Series
Big PACi NX Series high static pressure hide-away 20,0-25,0 kW · R32
nanoe™ X (Generator Mark 3).
Maximum piping length 100 m.
High external static pressure, maximum 200 Pa setting.

Kit (CZ-RTC5B remote controller £172 included) Indoor unit Outdoor unit RRP
Nominal capacity ηs,c 1) ηs,h 1) Dimension Weight Dimension 2) Weight
Cooling Heating HxWxD HxWxD
kW kW mm kg mm kg £
20,0 kW KIT-200PE4ZH8 19,0 22,4 237,8% 146,0% S-200PE4E 486 x 1 456 x 916 83 U-200PZH4E8 996 x 1 140 x 460 109 8,097
3ph
25,0 kW KIT-250PE4ZH8 22,0 24,0 213,0% 145,0% S-250PE4E 486 x 1 456 x 916 87 U-250PZH4E8 996 x 1 140 x 460 109 9,208

Piping information Electrical information (power supply to outdoor)


Kit kW 20,0 25,0 Three phase
Piping diameter (liquid - gas) Inch ½-⅞ ½-⅞ Kit kW 20,0 25,0
Pipe length range m 5 ~ 100 5 ~ 100 Recommended fuse A 30 30
Elevation difference (in / out) m 30 30 Connection in. / out. mm² 4x2,5 4x2,5
Pre-charged pipe length m 30 30
Additional gas amount g/m 80 80

1) Energy Label Scale from A+++ to D. For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825. 2) Add 100 mm for indoor unit or 70 mm for outdoor unit for piping port.

PACi NX with Water Heat Exchanger


The Water Heat Exchanger for chilled and hot water production
Hydronic solution with PACi NX for a quick return on investment.
Constant 55 °C flow available.
A+++ energy efficiency class (scale from A+++ to D).

Water Heat Exchanger Outdoor unit RRP


Nominal capacity Heating energy ηs,h Dimension Weight Dimension Weight Water Heat Outdoor
Cooling 1) Heating 2) efficiency class (LOT1) 4) Exchanger
3)
HxWxD HxWxD
35 °C 55 °C
kW kW A+++ to D A+++ to D mm kg mm kg £ £
PAW-200W5APAC-2 17,9 23,1 A+++ A++ 179,8% 550 x 455 x 205 27 U-200PZH4E8 996 x 1 140 x 460 109 4,494 4,061
1ph
PAW-250W5APAC-2 22,9 26,0 A+++ A+ 176,5% 550 x 455 x 205 27 U-250PZH4E8 996 x 1 140 x 460 109 4,870 4,784

Piping information Electrical information (power supply to outdoor)


Kit kW 20,0 25,0 Three phase
Piping diameter (liquid - gas) Inch ½-⅞ ½-⅞ Kit kW 20,0 25,0
Pipe length range m 5 ~ 100 5 ~ 100 Recommended fuse A 30 30
Elevation difference (in / out) m 30 30
Pre-charged pipe length m 30 30
Additional gas amount g/m 80 80

1) Data refers to 7 °C leaving chilled water temperature and 35 °C ambient air temperature, according to EN 14511 standard. 2) Data refers to 35 °C leaving warm water temperature and 7 °C ambient air
temperature according to EN 14511 standard. 3) Following COMMISSION REGULATION (EU) No 811/2013 for low-temperature heat pumps. Scale from A+++ to D. 4) Following COMMISSION REGULATION (EU) No
813/2013 for low-temperature heat pumps.

CONEX. Devices and apps.


CONEX provides comfort and control for varying
user needs. Accessible, flexible and scalable with
different controllers and apps.

Model Description RRP £


CZ-RTC6W CONEX wired remote controller (non-wireless),white 172
CZ-RTC6WBL CONEX wired remote controller with Bluetooth®, white 203
CZ-RTC6WBLW2 CONEX wired remote controller with Wi-Fi and Bluetooth®, white 286
CZ-RTC6 CONEX wired remote controller (non-wireless),black 172 Panasonic H&C Panasonic H&C Control Panasonic Comfort
Diagnosis App for App for end user, service Cloud App for end user.
CZ-RTC6BL CONEX wired remote controller with Bluetooth®, black 203 service and installer. and installer.
CZ-RTC6BLW2 CONEX wired remote controller with Wi-Fi and Bluetooth®, black 286

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
29
GENERAL INDEX

New Jet Air Stream


PACi NX Jet Air Stream · R32
Energy-saving solution for year-round heating and cooling
in large and high spaces.
High air volume up to 5 000 m³/h and long maximum air New
throw distance of 30 m.
Kit (PCZ-AHRX0012 remote controller £466 included) Indoor unit: Jet Air Stream Smart Outdoor unit RRP
Nominal capacity ηs,c 2) ηs,h 2) Dimension Weight Dimension Weight
Cooling Heating HxWxD HxWxD
kW kW mm kg mm kg £
1ph 14,0 kW KIT-140MC5ZH5 14,1 14,0 227% 155% P-VTVF140MC5-PE 802 x 1 105 x 893 88 U-140PZH4E5 996 x 980 x 370 86 10,276
14,0 kW KIT-140MC5ZH8 14,1 14,0 227% 155% P-VTVF140MC5-PE 802 x 1 105 x 893 88 U-140PZH4E8 996 x 980 x 370 84 10,652
3ph
25,0 kW KIT-250MC5ZH8 24,2 26,7 250% 155% P-VTVF250MC5-PE 1 026 x 1 458 x 953 130 U-250PZH4E8 996 x 1 140 x 460 109 11,386

Piping information Electrical information (power supply to outdoor)


Kit kW 14,0 14,0 25,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅝ ½-⅞ Kit kW 14,0 14,0 25,0
Pipe length range m 5 ~ 100 5 ~ 100 5 ~ 100 Recommended fuse A 40 16 30
Elevation difference (in / out) 2) m 15 / 30 4) 15 / 30 4) 30
Pre-charged pipe length m 30 30 30
Additional gas amount g/m 403) 403) 80

1) For models above 12 kW, the ηs,c / ηs,h values is calculated based on EN 14825. 2) Outdoor unit located lower / outdoor unit located higher. 3) 25g/m over 85 m.

Optional configurations* Front panel type Air flow (m³/h) RRP (indoor) £
P-VTVF140NC5-PE Jet Air Stream Standard Manual nozzles 2 500 5,682
P-VTVF250NC5-PE Jet Air Stream Standard Manual nozzles 5 000 8,392
P-VTVF140PC5-PE Jet Air Stream Ducted Ducted connection 2 500 4,507
P-VTVF250PC5-PE Jet Air Stream Ducted Ducted connection 5 000 6,040
* The product technical data is the same as Jet Air Stream Smart.

Jet Air Stream.


The Jet Air Stream provides an efficient and sustainable solution
for year-round heating and cooling in large spaces such as
gymnasiums, production areas, and warehouses.
It ensures optimal user comfort, a quiet environment, and is much
easier to install than comparable HVAC systems.

Efficient heating Long air Smart Jet - self- Quiet operation.


and cooling. distribution. directing nozzles.

Accessories for remote air intake Three versions available: Smart Jet - self-directing nozzles, Manual nozzles, and Ducted
configurations. connection.
Manual version. Ducted version. Jet Air Stream Smart Jet Air Stream Standard Jet Air Stream Ducted
A A P-VTVF***MC5-PE P-VTVF***NC5-PE P-VTVF***PC5-PE
Smart Jet - self-directing nozzles Manual nozzles Ducted connection

B B A | PCZ-AHRX0051. Ducted air intake plenum (1 x DN 355 mm) for VTVF140N and VTVF140P
A | PCZ-AHRX0052. Ducted air intake plenum (2 x DN 355 mm) for VTVF250N and VTVF250P
B | PCZ-AHRX0061. Ground air intake module (VTVF250 requires two of them)
C | PCZ-AHRX0071. Air supply grille for ducts

30
COMMERCIAL INDEX WATER SOLUTION

Low temperature compatible unit configurations


Solutions for cold rooms. Set the room temperature to 8 °C
Flexibility with different types of indoor units.
nanoe™ X technology for better indoor air quality.
Redundancy support for up to 2 systems using the CONEX controller
and up to 4 systems with the optional controller (PAW-PACR4).

Possible outdoor / indoor units combinations

Single Twin
Cooling capacity 1) 3,5 kW 4,9 kW 5,8 kW 6,9 kW 9,3 kW 11,6 kW 13,6 kW 18,5 kW 23,2 kW
Outdoor unit single phase U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5 U-100PZH4E5 U-125PZH4E5 U-140PZH4E5 — —
RRP £ 1,305 1,529 1,696 2,223 2,803 3,133 3,593 — —
Outdoor unit three phase — — — U-71PZH4E8 U-100PZH4E8 U-125PZH4E8 U-140PZH4E8 U-200PZH4E8 U-250PZH4E8
RRP £ — — — 2,286 2,847 3,273 3,969 4,143 4,880
Wall-mounted S-5010PK4E S-5010PK4E S-5010PK4E 2×S-5010PK4E 2×S-5010PK4E 2×S-5010PK4E 2×S-5010PK4E — —
RRP £ — —
4 way 90x90 cassette S-6071PU3E S-6071PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-1014PU3E 2×S-1014PU3E 2×S-1014PU3E 2×S-1014PU3E
RRP £ 1,253 1,253 1,359 1,359 1,359 1,359 2,718 2,718 2,718
Ceiling S-6071PT3E S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E 2×S-1014PT3E 2×S-1014PT3E 2×S-1014PT3E
RRP £ 1,276 1,276 1,606 1,606 1,606 1,606 3,212 3,212 3,212
Adaptive ducted unit S-6071PF3E S-6071PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E 2×S-1014PF3E 2×S-1014PF3E 2×S-1014PF3E
RRP £ 1,245 1,245 1,597 1,597 1,597 1,597 3,194 3,194 3,194
Jet Air Stream 2) P-VTVF140 P-VTVF140 P-VTVF250 P-VTVF250
RRP £ — - - - - PRICE DEPENDANT UPON CHOSEN MODEL TYPE
1) Under the condition with outdoor 35 °C (DB) and indoor 15 °C (WB). The CONEX controller CZ-RTC6(-BL/-BLW2) is required. 2) Available in all configurations: Smart, Standard, and Ducted. The CONEX
controller CZ-RTC6 (-BL/-BLW2) required for setup. However, the operation controller is built-in.

Cold room solutions with PACi NX Series. Temperature control at 8 °C.


The PACi NX series offers flexibility for specialised applications, beyond standard cooling. This
product can maintain room temperatures between +8 °C and +24 °C WB (or +10 °C and +30 °C DB).
To achieve this, the indoor unit must be sized for adequate coil and airflow requirements, and key
parameters adjusted accordingly.
Wired remote control. A wide range of
CZ-RTC6W/WBL/WBLW2 indoor units is
or CZ-RTC6/BL/BLW2. available.

PACi NX outdoor unit.


Temperature range.
In cooling. Outdoor air intake temperature °C DB.

50
40 Only allowed after installation of
wind and snow vents.
Temperature range
30
Indoor Outdoor
20
Cooling operation +8 ~ +24 °C WB -5 (-15) ~ 43 °C DB
10
Area where cooling capacity is
0
established for this purpose.
-10
-20
10 15 20 25 30
Indoor air intake temperature °C WB

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
31
GENERAL INDEX

PACi NX Series Elite ceiling - PT3 · R32


For light refrigeration applications.

nanoe™ X as a standard.

Pricing includes CZ-RTC6 remote controller and any required branch pipes

High temperature
Kit 36 50 60 71 100 125 140 200 250
Indoor unit - 1 S-6071PT3E S-6071PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E S-1014PT3E
Indoor unit - 2 — — — — — — S-1014PT3E S-1014PT3E S-1014PT3E
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5/8 U-100PZH4E5/8 U-125PZH4E5/8 U-140PZH3E5/8 U-200PZH2E8 U-250PZH2E8

Indoor Cooling capacity kW 3,50 4,90 5,80 6,60 8,80 11,20 13,00 18,50 23,20
15 °C EER 4,67 3,71 3,63 3,53 3,76 3,15 3,40 3,32 2,92
(WB) Input power kW 0,75 1,32 1,60 1,87 2,34 3,56 3,82 5,57 7,94
Outdoor Indoor Cooling capacity kW 3,19 4,46 5,28 6,01 8,01 10,19 11,83 16,84 21,11
35 °C 12 °C EER 4,33 3,45 3,37 3,28 3,49 2,92 3,16 3,08 2,71
(DB) (WB) Input power kW 0,74 1,29 1,57 1,83 2,29 3,49 3,74 5,46 7,78
Indoor Cooling capacity kW 2,10 2,94 3,48 3,96 5,28 6,72 7,80 11,10 13,92
8 °C EER 3,59 2,86 2,79 2,71 2,89 2,42 2,62 2,55 2,25
(WB) Input power kW 0,59 1,03 1,25 1,46 1,83 2,78 2,98 4,34 6,19
Indoor Cooling capacity kW 3,75 5,24 5,92 6,73 9,42 11,98 13,91 20,17 25,29
15 °C EER 5,43 4,32 3,93 3,83 4,37 3,66 3,96 3,94 3,46
(WB) Input power kW 0,69 1,21 1,50 1,76 2,15 3,28 3,51 5,12 7,30
Outdoor Indoor Cooling capacity kW 3,43 4,80 5,39 6,14 8,62 10,98 12,74 18,50 23,20
30 °C 12 °C EER 5,08 4,04 3,66 3,57 4,09 3,43 3,71 3,69 3,25
(DB) (WB) Input power kW 0,68 1,19 1,47 1,72 2,11 3,20 3,44 5,01 7,15
Indoor Cooling capacity kW 2,10 2,94 3,48 3,96 5,28 6,72 7,80 11,10 13,92
8 °C EER 4,00 3,18 3,02 2,94 3,22 2,70 2,92 2,85 2,50
(WB) Input power kW 0,53 0,92 1,15 1,35 1,64 2,49 2,67 3,90 5,56
Dimension (H x W x D) mm 235x1275x690 235x1275x690 235x1590x690 235x1590x690 235x1590x690 235x1590x690 235x1590x690 235x1590x690 235x1590x690
Indoor unit Net weight kg 34 34 40 40 40 40 40 40 40
nanoe™ X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Dimension (H x W x D) mm 695x875x320 695x875x320 695x875x320 996x980x370 996x980x370 996x980x370 996x980x370 1500x980x370 1500x980x370
Outdoor unit
Net weight kg 42 42 43 66 84 86 86 117 128

PACi NX Series Elite adaptive ducted unit - PF3 · R32


For light refrigeration applications.

nanoe™ X as a standard.
Pricing includes CZ-RTC6 remote controller and any required branch pipes

High temperature
Kit 36 50 60 71 100 125 140 200 250
Indoor unit - 1 S-6071PF3E S-6071PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E S-1014PF3E
Indoor unit - 2 — — — — — — S-1014PF3E S-1014PF3E S-1014PF3E
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5/8 U-100PZH4E5/8 U-125PZH4E5/8 U-140PZH4E5/8 U-200PZH2E8 U-250PZH2E8

Indoor Cooling capacity kW 3,50 4,90 5,80 6,60 8,80 11,20 13,00 18,50 23,20
15 °C EER 3,98 3,20 3,52 3,37 3,79 3,21 3,59 3,50 3,08
(WB) Input power kW 0,88 1,53 1,65 1,96 2,32 3,49 3,62 5,29 7,54
Outdoor Indoor Cooling capacity kW 3,19 4,46 5,28 6,01 8,01 10,19 11,83 16,84 21,11
35 °C 12 °C EER 3,69 2,97 3,26 3,13 3,52 2,98 3,33 3,25 2,86
(DB) (WB) Input power kW 0,86 1,50 1,62 1,92 2,27 3,42 3,55 5,18 7,39
Indoor Cooling capacity kW 2,10 2,94 3,48 3,96 5,28 6,72 7,80 11,10 13,92
8 °C EER 3,06 2,46 2,70 2,59 2,92 2,47 2,76 2,69 2,37
(WB) Input power kW 0,69 1,19 1,29 1,53 1,81 2,72 2,82 4,13 5,88
Indoor Cooling capacity kW 3,75 5,24 5,92 6,73 9,42 11,98 13,91 20,17 25,29
15 °C EER 4,63 3,72 3,81 3,65 4,41 3,73 4,18 4,14 3,65
(WB) Input power kW 0,81 1,41 1,55 1,84 2,13 3,21 3,33 4,87 6,94
Outdoor Indoor Cooling capacity kW 3,43 4,80 5,39 6,14 8,62 10,98 12,74 18,50 23,20
30 °C 12 °C EER 4,33 3,49 3,55 3,40 4,13 3,49 3,91 3,89 3,42
(DB) (WB) Input power kW 0,79 1,38 1,52 1,80 2,09 3,14 3,26 4,76 6,79
Indoor Cooling capacity kW 2,10 2,94 3,48 3,96 5,28 6,72 7,80 11,10 13,92
8 °C EER 3,41 2,75 2,93 2,81 3,25 2,75 3,08 3,00 2,64
(WB) Input power kW 0,62 1,07 1,19 1,41 1,62 2,44 2,53 3,70 5,28
Dimension (H x W x D) mm 250x1000x730 250x1000x730 250x1000x730 250x1400x730 250x1400x730 250x1400x730 250x1400x730 250x1400x730 250x1400x730
Indoor unit Net weight kg 30 30 30 39 39 39 39 39 39
nanoe™ X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Dimension (H x W x D) mm 695x875x320 695x875x320 695x875x320 996x980x370 996x980x370 996x980x370 996x980x370 1500x980x370 1500x980x370
Outdoor unit
Net weight kg 42 42 43 66 84 86 84 117 128

32
COMMERCIAL INDEX COMMERCIAL

PACi NX Series Elite 4 way 90x90 cassette - PU3 · R32


For light refrigeration applications.

nanoe™ X as a standard.

Pricing includes CZ-RTC6 remote controller and any required branch pipes

High temperature
Kit 36 50 60 71 100 125 140 200 250
Indoor unit - 1 S-6071PU3E S-6071PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-1014PU3E S-1014PU3E
Indoor unit - 2 — — — — — — S-1014PU3E S-1014PU3E S-1014PU3E
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5/8 U-100PZH4E5/8 U-125PZH4E5/8 U-140PZH4E5/8 U-200PZH2E8 U-250PZH2E8

Indoor Cooling capacity kW 3,50 4,90 5,80 6,90 8,80 11,60 13,00 18,50 23,20
15 °C EER 5,12 4,05 3,81 3,67 4,09 3,47 3,82 3,38 2,97
(WB) Input power kW 0,68 1,21 1,52 1,88 2,15 3,34 3,40 5,48 7,82
Outdoor Indoor Cooling capacity kW 3,19 4,46 5,28 6,28 8,01 10,56 11,83 16,84 21,11
35 °C 12 °C EER 4,78 3,76 3,54 3,41 3,80 3,22 3,55 3,13 2,75
(DB) (WB) Input power kW 0,67 1,19 1,49 1,84 2,11 3,27 3,33 5,37 7,66
Indoor Cooling capacity kW 2,10 2,94 3,48 4,14 5,28 6,96 7,80 11,10 13,92
8 °C EER 3,96 3,12 2,94 2,82 3,15 2,67 2,94 2,60 2,28
(WB) Input power kW 0,53 0,94 1,19 1,47 1,68 2,61 2,65 4,27 6,10
Indoor Cooling capacity kW 3,75 5,24 5,92 7,04 9,42 12,41 13,91 20,17 25,29
15 °C EER 5,99 4,71 4,14 3,98 4,76 4,04 4,45 4,00 3,51
(WB) Input power kW 0,63 1,11 1,43 1,77 1,98 3,07 3,13 5,04 7,19
Outdoor Indoor Cooling capacity kW 3,43 4,80 5,39 6,42 8,62 12,41 12,74 18,50 23,20
30 °C 12 °C EER 5,60 4,41 3,86 3,71 4,46 4,04 4,16 3,75 3,30
(DB) (WB) Input power kW 0,61 1,09 1,40 1,73 1,94 3,07 3,06 4,93 7,04
Indoor Cooling capacity kW 2,10 2,94 3,48 4,14 5,28 6,96 7,80 11,10 13,92
8 °C EER 4,41 3,47 3,18 3,06 3,51 2,98 3,28 2,89 2,54
(WB) Input power kW 0,48 0,85 1,09 1,35 1,51 2,34 2,38 3,84 5,47
Dimension (H x W x D) mm 256x840x840 256x840x840 256x840x840 319x840x840 319x840x840 319x840x840 319x840x840 319x840x840 319x840x840
Indoor unit Net weight kg 19 19 20 25 25 25 25 25 25
nanoe™ X Generator Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1 Mark 1
Dimension (H x W x D) mm 695x875x320 695x875x320 695x875x320 996x980x370 996x980x370 996x980x370 996x980x370 1500x980x370 1500x980x370
Outdoor unit
Net weight kg 42 42 43 66 84 86 86 117 128

PACi NX Series Elite wall-mounted - PK4 · R32


For light refrigeration applications.

nanoe™ X as a standard.

Pricing includes CZ-RTC6 remote controller and any required branch pipes

High temperature
Kit 36 50 60 71 100 125 140
Indoor unit - 1 S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E
Indoor unit - 2 S-5010PK4E S-5010PK4E S-5010PK4E S-5010PK4E
Outdoor unit U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 U-71PZH4E5/8 U-100PZH4E5/8 U-125PZH4E5/8 U-140PZH4E5/8
Indoor Cooling capacity kW 3,50 4,90 5,80 6,90 8,80 11,60 13,00
15 °C EER 4,55 3,83 3,56 3,17 2,97 3,06 3,34
(WB) Input power kW 0,77 1,28 1,63 2,18 2,96 3,79 3,89
Outdoor Indoor Cooling capacity kW 3,19 4,46 5,28 6,28 8,01 10,56 11,83
35 °C 12 °C EER 4,22 3,55 3,30 2,94 2,76 2,84 3,10
(DB) (WB) Input power kW 0,75 1,25 1,60 2,14 2,90 3,71 3,81
Indoor Cooling capacity kW 2,10 2,94 3,27 4,14 5,28 6,96 7,80
8 °C EER 3,50 2,94 2,14 2,44 2,28 2,35 2,57
(WB) Input power kW 0,60 1,00 1,52 1,70 2,31 2,96 3,03
Indoor Cooling capacity kW 3,75 5,24 5,92 7,04 9,42 12,41 13,91
15 °C EER 5,29 4,45 3,86 3,44 3,45 3,56 3,88
(WB) Input power kW 0,71 1,18 1,53 2,05 2,72 3,49 3,58
Outdoor Indoor Cooling capacity kW 3,43 4,80 5,39 6,42 8,62 11,37 12,74
30 °C 12 °C EER 4,95 4,17 3,60 3,20 3,23 3,33 3,64
(DB) (WB) Input power kW 0,69 1,15 1,50 2,01 2,66 3,41 3,50
Indoor Cooling capacity kW 2,10 2,94 3,48 4,14 5,28 6,96 7,80
8 °C EER 3,90 3,28 2,97 2,64 2,55 2,62 2,86
(WB) Input power kW 0,54 0,90 1,17 1,57 2,16 2,65 2,72
Dimension (H x W x D) mm 302 x 1 120 x 236 302 x 1 120 x 236 302 x 1 120 x 236 302 x 1 120 x 236 302 x 1 120 x 236 302 x 1 120 x 236 302 x 1 120 x 236
Indoor unit Net weight kg 14 14 14 14 14 14 14
nanoe™ X Generator Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2 Mark 2
Dimension (H x W x D) mm 695 x 875 x 320 695 x 875 x 320 695 x 875 x 320 996 x 980 x 370 996 x 980 x 370 996 x 980 x 370 996 x 980 x 370
Outdoor unit
Net weight kg 42 42 43 66 84 86 86

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
33
GENERAL INDEX

Commercial twin, triple and double-twin systems


Outdoor units PACi Elite Commercial twin, triple and double-
twin systems · R32
Up to 4 indoor units can be connected to the same outdoor unit.

Outdoor unit Nominal capacity 1) Dimension Weight RRP


Cooling Heating HxWxD
Series kW kW mm kg £
7,1 kW U-71PZH4E5 PACi NX 7,1 8,0 996 x 980 x 370 66 2,223
10,0 kW U-100PZH4E5 PACi NX 9,5 11,2 996 x 980 x 370 84 2,803
1ph
12,5 kW U-125PZH4E5 PACi NX 12,5 14,0 996 x 980 x 370 98 3,133
14,0 kW U-140PZH4E5 PACi NX 13,4 16,0 996 x 980 x 370 98 3,593
7,1 kW U-71PZH4E8 PACi NX 6,8 8,0 996 x 980 x 370 66 2,286
10,0 kW U-100PZH4E8 PACi NX 9,5 11,2 996 x 980 x 370 84 2,847
12,5 kW U-125PZH4E8 PACi NX 12,1 14,0 996 x 980 x 370 98 3,273
3ph
14,0 kW U-140PZH4E8 PACi NX 13,4 16,0 996 x 980 x 370 98 3,969
20,0 kW U-200PZH4E8 Big PACi NX 19,0 22,4 996 x 1 140 x 460 109 4,143
25,0 kW U-250PZH4E8 Big PACi NX 22,0 24,0 996 x 1 140 x 460 109 4,880

Piping information Electrical information (power supply to outdoor)


Outdoor unit kW 7,1 10,0 12,5 14,0 20,0 25,0 Single phase
Piping diameter (liquid - gas) Inch ⅜- ⅝ ⅜- ⅝ ⅜- ⅝ ⅜- ⅝ ½- ⅞ ½- ⅞ Outdoor unit kW 7,1 10,0 12,5 14,0
5~ 5~ 5~ 5~ 5~ Recommended fuse A 25 35 40 40
Pipe length range m 5 ~ 60
100 100 100 100 100 Connection in. / out. mm² 4x2,5
15 / 15 / 15 / 15 / Three phase
Elevation difference (in / out) m 30 30
30 2) 30 2) 30 2) 30 2) Outdoor unit kW 7,1 10,0 12,5 14,0 20,0 25,0
Pre-charged pipe length m 30 304) 304) 304) 30 30 Recommended fuse A 16 16 16 16 30 30
Additional gas amount g/m 40 40 40 40 80 80 Connection in. / out. mm² 4x2,5 — —

PACi Elite from 7,1 to 25,0 kW simultaneous operation system combinations · R32 3)
Outdoor 7,1 kW 10,0 kW 12,5 kW 14,0 kW 20,0 kW 25,0 kW
U-71 (S-3650 + S-3650) U-100 (S-3650 + S-3650) U-125 (S-6071 + S-6071) U-140 (S-6071 + S-6071)
Twin U-200 (S-1014 + S-1014) U-250 (S-1014 + S-1014)
U-71 (S-2545 + S-2545) U-100 (S-5010 + S-5010) U-125 (S-5010 + S-5010) U-140 (S-5010 + S-5010)
U-100 (S-3650 + S-3650 U-125 (S-3650 + S-3650 U-140 (S-3650 + S-3650
U-71 (S-25 + S-25 + S-25)
+ S-3650) + S-3650) + S-3650) U-200 (S-6071 + S-6071
Triple U-71 (S-2545 + S-2545 + —
U-100 (S-2545 + S-2545 + U-125 (S-2545 + S-2545 + U-140 (S-2545 + S-2545 + + S-6071)
S-2545)
S-2545) S-2545) S-2545)
U-100 (S-25 + S-25 + U-125 (S-3650 + S-3650
S-25 + S-25) + S-3650 + S-3650) U-200 (S-3650 + S-3650 U-250 (S-6071 + S-6071
Double-twin — —
U-100 (S-2545 + S-2545 + U-125 (S-2545 + S-2545 + + S-3650 + S-3650) + S-6071 + S-6071)
S-2545 + S2545) S-2545 + S2545)

1) With 4 way 90x90 cassette (PU3). 2) Outdoor unit located lower / outdoor unit located higher. 3) 7,1 to 14,0 kW: Available with indoor unit types PY3, PF3, PK3, PT3, and PU3. 20,0 - 25,0 kW: Available with
indoor unit types PF3 and PU3. 4) triple & double twin 20.

Outdoor units PACi NX Standard Commercial twin system · R32


Up to 2 indoor units can be connected to the same outdoor unit.

Outdoor unit Nominal capacity 1) Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
10,0 kW U-100PZ3E5 10,0 10,0 996 x 980 x 370 83 1,869
1ph 12,5 kW U-125PZ3E5 12,5 12,5 996 x 980 x 370 87 2,230
14,0 kW U-140PZ3E5 14,0 14,0 996 x 980 x 370 87 2,910
10,0 kW U-100PZ3E8 10,0 10,0 996 x 980 x 370 83 1,984
3ph 12,5 kW U-125PZ3E8 12,5 12,5 996 x 980 x 370 87 2,300
14,0 kW U-140PZ3E8 14,0 14,0 996 x 980 x 370 87 2,945

Piping information Electrical information (power supply to outdoor)


Outdoor unit kW 10,0 12,5 14,0 Single phase Three phase
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅝ ⅜-⅝ Outdoor unit kW 10,0 12,5 14,0 10,0 12,5 14,0
Pipe length range m 5 ~ 50 5 ~ 50 5 ~ 50 Recommended fuse A 35 40 40 16 20 20
Elevation difference (in / out) 2) m 15 / 30 15 / 30 15 / 30 Connection in. / out. mm² 4x2,5 4x2,5
Pre-charged pipe length m 30 30 30
Additional gas amount g/m 45 45 45

PACi NX Standard from 10,0 to 14,0 kW simultaneous operation system combinations · R32 3)
Outdoor 10,0 kW 12,5 kW 14,0 kW
Twin U-100 (S-3650 + S-3650) U-125 (S-6071 + S-6071) - U-125 (S-6010 + S-6010) U-140 (S-6071 + S-6071) - U-140 (S-6010 + S-6010)

1) With 4 way 90x90 cassette (PU3). 2) Outdoor unit located lower / outdoor unit located higher. 3) Available with indoor unit types PY3, PF3, Order our full PACi range online at
PK3, PT3, and PU3. www.panasonic-hvac-direct.co.uk

34
COMMERCIAL INDEX COMMERCIAL

Compatible indoor units for multi combinations


Indoor units Commercial twin, triple and double-twin systems
Power supply to outdoor.
nanoe™ X as a standard.

Wall-mounted - PK4 Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,5 - 5,0 kW S-2545PK4E 2,5 - 5,0 2,8 - 5,6 290 x 765 x 214 9 867
1ph 6,0 - 7,1 kW S-5010PK4E 6,1 - 7,1 6,1 - 7,8 295 x 1 060 x 249 14 1,162
10,0 kW S-5010PK4E 9,5 9,5 295 x 1 060 x 249 14 1,162

Panel (sold separately).


CZ-KPY4

4 way 60x60 cassette - PY3 Nominal capacity Dimension (indoor) Weight (indoor) Dimension (panel) Weight (panel) RRP
(panel CZ-KPY4)
Cooling Heating HxWxD HxWxD Indoor Panel
kW kW mm kg mm kg £ £
2,5 kW S-25PY3E 2,5 3,2 243 x 575 x 575 15 30 x 625 x 625 2,8 738 266
3,6 kW S-36PY3E 3,6 4,0 243 x 575 x 575 15 30 x 625 x 625 2,8 782 266
1ph
5,0 kW S-50PY3E 5,0 5,6 243 x 575 x 575 15 30 x 625 x 625 2,8 887 266
6,0 kW S-60PY3E 6,0 7,0 243 x 575 x 575 15 30 x 625 x 625 2,8 1,083 266

Panels (sold separately):

Standard, white Econavi, white Standard, graphite


(RAL9003). (RAL9003). black (RAL9011).
CZ-KPU3W CZ-KPU3AW CZ-KPU3B

4 way 90x90 cassette - PU3 Nominal capacity Dimension (indoor) Weight Dimension (panel) Weight RRP
(panels CZ-KPU3W / CZ-KPU3B / (indoor) (panel)
Cooling Heating HxWxD HxWxD Indoor Panel 3/3B Panel 3A
CZ-KPU3AW)
kW kW mm kg mm kg £ £ £
3,6 - 5,0 kW S-3650PU3E 3,6 - 5,0 4,0 - 5,6 256 x 840 x 840 19 33,5 x 950 x 950 5 668 242 328
6,0 - 7,1 kW S-6071PU3E 6,0 - 7,1 7,0 - 8,0 256 x 840 x 840 20 33,5 x 950 x 950 5 1,011 242 328
1ph
10,0 - 12,5 kW S-1014PU3E 10,0 - 12,5 11,2 - 14,0 319 x 840 x 840 25 33,5 x 950 x 950 5 1,117 242 328
14,0 kW S-1014PU3E 14,0 16,0 319 x 840 x 840 25 33,5 x 950 x 950 5 1,117 242 329

Ceiling - PT3 Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
3,6 - 5,0 kW S-3650PT3E 3,5 - 5,0 4,0 - 5,6 235 x 960 x 690 26 1,001
6,0 - 7,1 kW S-6071PT3E 6,0 - 6,8 7,0 - 8,0 235 x 1 275 x 690 34 1,276
1ph
10,0 - 12,5 kW S-1014PT3E 9,5 - 12,1 11,2 - 14,0 235 x 1 590 x 690 40 1,606
14,0 kW S-1014PT3E 13,4 16,0 235 x 1 590 x 690 40 1,606

Adaptive ducted unit - PF3 Nominal capacity Dimension Weight External static pressure RRP
Cooling Heating HxWxD Nominal (Min - Max)
kW kW mm kg Pa £
3,6 - 5,0 kW S-3650PF3E 3,6 - 5,0 4,0 - 5,6 250 x 800 x 730 25 30 (10 - 150) - 30 (10 - 150) 1,002
6,0 - 7,1 kW S-6071PF3E 5,7 - 6,8 7,0 - 7,5 250 x 1 000 x 730 30 30 (10 - 150) - 30 (10 - 150) 1,245
1ph
10,0 - 12,5 kW S-1014PF3E 9,5 - 12,1 10,8 - 13,5 250 x 1 400 x 730 39 40 (10 - 150) - 50 (10 - 150) 1,597
14,0 kW S-1014PF3E 13,4 15,5 250 x 1 400 x 730 39 50 (10 - 150) 1,597

* The data shown in these tables are based on PACi NX Elite combinations. The 2,5 kW capacity is based on PACi NX Standard combinations.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
35
GENERAL INDEX

Commercial ventilation solutions


AHU connection kit PAH3M-1 for PACi NX and PACi
CONEX Bluetooth® version (CZ-RTC6BL) is built-in.
Easy connection and set-up is possible via Bluetooth®.
0-10 V demand control.

Reference With PACi NX Elite With PACi NX Standard


Nominal capacity Nominal capacity Dimension Weight RRP
Cooling Heating Cooling Heating HxWxD
kW kW kW kW mm kg £
2,5 kW PAW-280PAH3M-1 — — 2,5 3,2 500 x 400 x 150 11,5
3,6 kW PAW-280PAH3M-1 3,6 3,6 3,6 3,6 500 x 400 x 150 11,5
5,0 kW PAW-280PAH3M-1 5,0 5,0 5,0 5,0 500 x 400 x 150 11,5
6,0 kW PAW-280PAH3M-1 6,0 6,0 6,0 6,0 500 x 400 x 150 11,5
7,5 kW PAW-280PAH3M-1 7,1 7,5 7,1 7,1 500 x 400 x 150 11,5
1,844
10,0 kW PAW-280PAH3M-1 10,0 10,8 10,0 10,0 500 x 400 x 150 11,5
12,5 kW PAW-280PAH3M-1 12,5 13,5 12,5 12,5 500 x 400 x 150 11,5
14,0 kW PAW-280PAH3M-1 14,0 15,5 14,0 14,0 500 x 400 x 150 11,5
20,0 kW PAW-280PAH3M-1 19,0 22,4 — — 500 x 400 x 150 11,5
25,0 kW PAW-280PAH3M-1 22,0 24,0 — — 500 x 400 x 150 11,5

Piping information
Model kW 2,5 3,6 5,0 6,0 7,5 10,0 12,5 14,0 20,0 25,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ½-⅞ ½-⅞ ½-⅞
Pipe length range (Standard) m 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 — —
Pipe length range (Elite) m — 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 100
Elevation difference (in / out) m 15 30 30 30 30 30 30 30 30 30

Electric air curtain


Comprehensive product line up (width: 0,9 m 1,2 m and 1,5 m).
Simple structure for easy installation and maintenance.

Reference Width Air flow Consumption Dimension Weight RRP


Hi / Lo Hi / Lo HxWxD
mm m³/h W mm kg £
FY-3009U1 900 1 100 / 920 76 / 70 231,5 x 900 x 212 12,0 809
1ph FY-3012U1 1 200 1 400 / 1 270 94 / 85 231,5 x 1 200 x 212 14,5 906
FY-3015U1 1 500 2 000 / 1 800 131 / 110 231,5 x 1 500 x 212 18,0 1,061

Air curtain with DX coil, connected to PACi systems


Compatible with R32 and R410A refrigerant.
Simple structure for easy installation and maintenance.
Easy redirection of air flow with manual deflector.

Reference Maximum capacity Air flow Dimension 3) Weight RRP


Cooling 1) Heating 2) Hi HxWxD
kW kW m³/h mm kg £
PAW-10PAIRC-LS-1 6,1 7,9 1 800 260 (+140) x 1 000 x 460 50 8,777
Air outlet height PAW-15PAIRC-LS-1 9,7 12,0 2 700 260 (+140) x 1 500 x 460 65 10,236
2,7 m PAW-20PAIRC-LS-1 13,0 15,0 3 600 260 (+140) x 2 000 x 460 80 11,540
PAW-25PAIRC-LS-1 17,0 19,0 4 500 260 (+140) x 2 500 x 460 95 12,929
1ph
PAW-10PAIRC-HS-1 9,1 11,8 2 700 260 (+140) x 1 000 x 460 55 9,147
Air outlet height PAW-15PAIRC-HS-1 13,0 15,8 3 600 260 (+140) x 1 500 x 460 65 10,528
3,0 m PAW-20PAIRC-HS-1 19,5 23,6 5 400 260 (+140) x 2 000 x 460 85 12,051
PAW-25PAIRC-HS-1 23,7 27,6 6 300 260 (+140) x 2 500 x 460 110 13,197

LS / PACi outdoor combination* PACi Elite PACi Standard HS / PACi outdoor combination* PACi Elite PACi Standard
Operation until 40 °C 35 °C 30 °C 40 °C 35 °C 30 °C Operation until 40 °C 35 °C 30 °C 40 °C 35 °C 30 °C
PAW-10PAIRC-LS-1 U-100 U-100 U-50 U-100 U-100 U-60 PAW-10PAIRC-HS-1 U-200 U-100 U-100 — U-100 U-100
PAW-15PAIRC-LS-1 U-200 U-100 U-100 — U-100 U-100 PAW-15PAIRC-HS-1 U-200 U-200 U-100 — — U-100
PAW-20PAIRC-LS-1 U-200 U-140 U-100 — — U-100 PAW-20PAIRC-HS-1 — U-250 U-200 — — —
PAW-25PAIRC-LS-1 U-250 U-200 U-125 — — U-125 PAW-25PAIRC-HS-1 — U-250 U-200 — — —

1) Cooling capacity DX coil, air temperature in / out +27 / +18 °C, R32 and R410. 2) Heating capacity condenser, air temperature in / out +20 / +33 °C, R32 and R410. In the case of lower outdoor temperatures, an
outdoor model with higher capacity may be necessary. 3) 140 mm is the height of an electrical box if it is installed on the top.

36
COMMERCIAL INDEX COMMERCIAL

Commercial ventilation solutions


Ceiling mounted air-e nanoe™ X Generator
nanoe™ X (Generator Mark 1).
Silent operation.
Low power consumption.

Reference Air flow Consumption Sound pressure Dimension Net weight RRP
Panel Hole size
m³/h W dB(A) mm mm kg £
1ph FV-15CSD1G 16 4 25,5 Ø200 Ø145 1,1 363

Ceiling mounted air-e nanoe™ X Generator


Bringing nature’s balance indoors.
Deodorises and inhibits certain bacteria, viruses, mould,
pollens and allergens for better indoor air quality.

One device is suitable for around 20 m² (with a ceiling height 3 m) 3m

Ex. 3 air-e devices are required for the room size 60 m².
The nanoe™ X performance varies depending on the room size, environment and usage. nanoe™ X
is not a medical device. 3 air-e
devices

60 m²

Smart multi-site control solution.


Modern and scalable energy management for
your Heating & Cooling Solutions.
The smart multi-site control solution allows you
to have complete control of all your installations.
With a simple click, all your units from several
locations, receive status updates in real-time
preventing breakdowns and optimising costs.

Installation. Connectivity. Reliability. Use. Roles and permission. Security.


Easy installation and A standard LAN connection 24/7/365 days connection. Real-time control from Easily configure different Highly secure communication
configuration. with internet access (fibre or anywhere. access roles for each user. and complaint with GDPR.
mobile).

DETAILED REFERENCES IS IN PAGE 65

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
37
ACCESSORIES AND CONTROL GENERAL INDEX

Drain kits RRP £ VRF Smart Connectivity+ RRP £

Drain kit to suit outdoor units from 3,6 CZ-50DRS1 23 Remote controller Panasonic Net Con, SER8150R0B1194 608
to 7,1 kW. RH, No PIR, R1/R2.
Drain kit to suit outdoor units from CZ-140DRS1 30 Remote controller Panasonic Net Con, SER8150R5B1194 648
10,0 to 25 kW. RH, PIR, R1/R2.
Wireless ZigBee® Pro module / Green VCM8000V5094P 220
Branch Pipes, Header RRP £ Com card.

Branch pipe. CZ-P224BK2BM 109 Door / window wireless sensor. SED-WDC-G-5045 250

Branch pipe (from 22,4 kW to 68 kW). CZ-P680BK2BM 179 Wall / ceiling (motion) wireless sensor. SED-MTH-G-5045 305

Header. CZ-P3HPC2BM 153 CO2 sensor. SED-CO2-G-5045 784

Sensor with room temperature and SED-TRH-G-5045 247


Outdoor accessories RRP £ humidity.

Tray for condenser water compatible PAW-WTRAY 158 Water leakage sensor. SED-WLS-G-5045 240
with outdoor elevation platform.

Outdoor elevation platform. PAW-GRDSTD40 158 Cover frame. Silver. FAS-00 51


Dimension (H x W x D):
400 x 900 x 400 mm
Outdoor base ground support for noise PAW-GRDBSE20 145 Cover frame. White. FAS-01 51
and vibration absorption.
Dimension (H x W x D): 600 x 95 x 130 mm
Safe working load: 500 kg
Cover frame. Glossy translucent white. FAS-03 91

Panels RRP £
Cover frame. Light tan wood. FAS-05 71
Panel for 4 way 60x60 cassette - PY3. CZ-KPY4 266

Cover frame. Dark brown wood. FAS-06 71


Standard panel for 4 way 90x90 CZ-KPU3W 242
cassette, white (RAL9003).
Cover frame. Dark black wood. FAS-07 71
Econavi panel for 4 way 90x90 CZ-KPU3AW 328
cassette, white (RAL9003).
Cover frame. Brushed steel finish. FAS-10 91
Standard panel for 4 way 90x90 CZ-KPU3B 242
cassette, graphite black (RAL9011).

Controller and touch controllers for hotels with dry


RRP £
Sensors RRP £ contacts
Modbus RS-485 touch room controller PAW-RE2C4-MOD-WH 523
Econavi energy saving sensor. CZ-CENSC1 179 with I/O, white.
Touch display control with 2 digital PAW-RE2D4-WH 319
inputs, white.
Remote temperature sensor. CZ-CSRC3 129 Modbus RS-485 touch room controller PAW-RE2C4-MOD-BK 523
with I/O, black.
Touch display control with 2 digital PAW-RE2D4-BK 319
Cassette fresh air-intake kit. CZ-FDU3+CZ-ATU2
inputs, black.

IAQ filter for adaptive ducted unit RRP £


Hotel sensors for dry contacts RRP £

BION air pollutant filter for PAW-APF800F TBC Wall motion sensor 24 V. PAW-WMS-DC 220
S-3650PF3E.
BION air pollutant filter for PAW-APF1000F TBC Wall motion sensor 240 V AC. PAW-WMS-AC 220
S-6071PF3E.
* Tentative Ceiling motion sensor 24 V. PAW-CMS-DC 220
image. BION air pollutant filter for PAW-APF1400F TBC
S-1014PF3E. Ceiling motion sensor 240 V AC. PAW-CMS-AC 220

Power supply 24 V. PAW-24DC 71


Plenums RRP £

Air outlet plenum for S-3650PF3E. CZ-56DAF2 203 Door or window contact. PAW-DWC 24
Air outlet plenum for S-6071PF3E. CZ-90DAF2 249
Air outlet plenum for S-1014PF3E. CZ-160DAF2 286

38
COMMERCIAL INDEX ACCESSORIES AND CONTROL

Centralised controls RRP £ Individual controls RRP £

System controller for 64 indoor units CZ-64ESMC3 897 CONEX wired remote controller (non- CZ-RTC6W 172
with weekly timer. wireless), white.
CONEX wired remote controller with CZ-RTC6WBL 286
Bluetooth®, white.
Central ON / OFF controller, up to 16 CZ-ANC3 608
groups, 64 indoor units. CONEX wired remote controller with CZ-RTC6WBLW2 286
Wi-Fi and Bluetooth®, white.
CONEX wired remote controller (non- CZ-RTC6 172
Intelligent controller (touch screen/web CZ-256ESMC3 3,359 wireless), black.
server) to control up to 256 indoors with
CONEX wired remote controller with CZ-RTC6BL 286
included load distribution ratio (LDR).
Bluetooth®, black.
CONEX wired remote controller with CZ-RTC6BLW2 286
Wi-Fi and Bluetooth®, black.
Panasonic AC Smart Cloud RRP £ Design wired remote controller with CZ-RTC5B 172
Econavi function.

Panasonic AC Smart Cloud. Cloud CZ-CFUSCC1 508 Infrared remote controller for wall- CZ-RWS3 129
internet control. Up to 128 groups. mounted.
Controls 128 units.

Detailed references is in page 65. Infrared remote controller and CZ-RWS3 + 256
receiver for 4 way 60x60 cassette - CZ-RWRY3
PY3 with panel.
BMS interface with S-Link RRP £
Infrared remote controller and CZ-RWS3 + 328
receiver for 4 way 90x90 cassette. CZ-RWRU3W
A unified interface supporting Modbus, PAW-AC2-BMS-16 2,620
BACnet, and KNX protocols for up to
16 indoor units. Infrared remote controller and CZ-RWS3 + 328
receiver for ceiling. CZ-RWRT3
A unified interface supporting Modbus, PAW-AC2-BMS-64 3,760
BACnet, and KNX protocols for up to
64 indoor units. Infrared remote controller and CZ-RWS3 + 328
receiver for all indoor units. CZ-RWRC3
A unified interface supporting Modbus, PAW-AC2-BMS-128 5,034
BACnet, and KNX protocols for up to
128 indoor units.
Accessories PCB RRP £
Accessories interfaces RRP £
T10 interface PCB with digital and PAW-T10 120
relay connections.
Commercial Wi-Fi Adaptor. CZ-CAPWFC2 207

PCB for server room application, PAW-PACR4 2,044


control up to 4 indoor unit groups,
KNX interface (Intesis). PAW-RC2-KNX-1i 408
redundancy, backup, etc.
Connector to PACi NX indoor unit’s PAW-OPT-NX 32
PCB to provide OPT functions.
Modbus RTU interface (Intesis). PAW-RC2-MBS-1 408

Redundancy of 2 units YKEA-1. PAW-SERVER-PKEA-1 282


SG Ready.
Modbus RTU interface to control 4 PAW-RC2-MBS-4 944
indoor/groups (Intesis).

BACnet IP and MSTP interface PAW-RC2-BAC-1 674 Accessories cables RRP £


(Intesis).
Cable for all the T10 functions. CZ-T10 59
KNX interface (Airzone). PAW-AZRC-KNX-1 348

Cable to operate external EC fan. PAW-FDC 59


Modbus RTU interface (Airzone). PAW-AZRC-MBS-1 348

Cable for all option monitoring PAW-OCT 59


signals.
BACnet IP and MSTP interface PAW-AZRC-BAC-1 634
(Airzone).
Cable with force thermo OFF/leakage PAW-EXCT 59
detection.
RAC interface adapter for integration CZ-CAPRA1 194
into S-Link, plus external input and
alarm/status output (for YKEA-1 units).
Accessories for Jet Air Stream RRP £
Centralised controls. Connection with general equipment RRP £
Touch panel controller with Modbus PCZ-AHRX0012 466
integration and group control up to 8
Adaptor for ON / OFF control of CZ-CAPC3 387
units.
external devices.
Recessed mounting box for controller. PCZ-AHRP0681 57

Mini series parallel device controlling CZ-CAPBC2 324


indoor units, maximum 1 group and 8
Ducted air intake plenum (1 x DN PCZ-AHRX0051 318
indoor unit.
355 mm) for VTVF140N and VTVF140P.
Communication Adaptor. Up to 128 CZ-CFUNC2 1,413
groups. Controls 128 units. Ducted air intake plenum (2 x DN PCZ-AHRX0052 522
355 mm) for VTVF250N and VTVF250P.

Ground air intake module (VTVF250 PCZ-AHRX0061 979


requires two of them).

Air supply grille for ducts. PCZ-AHRX0071 178

39
GENERAL INDEX

Commercial VRF Systems


Panasonic VRF Systems are specifically designed for energy
saving, easy installation and high efficiency performance. A
wide range of outdoor and indoor unit models offer unique
features which are designed for the most demanding offices
and large buildings.

40
VRF SYSTEMS

New 2025
2-Pipe ECOi EX MZ1 Series R32.
Extreme efficiency, quality, compact.
With advanced R32 refrigerant technology and optimised system design, this series offers a more sustainable solution
compared to R410A.
· Compact outdoor unit with a significant 43% 1) footprint reduction, delivering high seasonal efficiency, reliable quality, and
R32 standard compliance
· The series uses 57% 2) less R32 refrigerant than R410A, minimizing the need for extra safety measures
· Extensive R32 Range with all air-to-air indoor units equipped with nanoe™ X, along with ERVs, AHU connection kits, and a
hydronic module option for heating and hot water production
· A wide range of connectivity options, including stand-alone, central, and remote monitoring, with BMS integration for
seamless operation
1) 12 HP model compared to the equivalent conventional R410A ECOi EX ME2.
2) Panasonic’s internal research. 12 HP model with 30 m piping installation.

ERV with DX coil - HRPT Series.


· Dual flow ventilation with EC fan, featuring high efficiency heat recovery (>85% η)
· 2 types of polypropylene heat exchanger (high efficiency and sensible) with counter-current flows and integrated bypass
as standard
· Modbus connection available

BION air pollutant filter.


IAQ solution filtering certain types of pollutants, such as nitrogen dioxide (NO2), nitrogen oxides (NOX) and ozone (O3).
Designed for the F3 type adaptive duct.

Mini ECOi LZ2 Series R32.


Outstanding efficiency in a compact body and continuous operation even at extreme ambient temperature.
· Low GWP and less refrigerant
· SEER up to 8,50 and SCOP levels up to 5,05 1)
· Operation range down to -20 °C in heating and up to 52 °C in cooling
· Optional R32 safety measures and Pump Down System available
1) 4 HP model.

Electricity or Gas or Hybrid? Various VRF technologies satisfy your project needs.
· VRF ECOi EX Series: A game-changing VRF system delivering outstanding energy-saving performance. Available in 2-Pipe
(8 - 80 HP) and 3-Pipe (8 - 48 HP) system
· Gas driven VRF, ECO G Series: For the project location with lack of electricity. Available in 2-Pipe (16 - 60 HP) and 3-Pipe
(16 - 25 HP) system
· Hybrid GHP/EHP taking advantage of gas and electricity to achieve better energy savings

Air to air indoor units with nanoe™ X.


· For better indoor air quality
· Quick effect in even large space
· Bacteriophage inhibition 99% in 4 hours at the room size 139 m² 1)
· nanoe™ X is a filter free solution that does not require maintenance
1) [Test organization] SGS Inc. [Test subject] Adhesive virus (bacteriophage) [Test volume] 139 m³ [Test result] Inhibited 99% in 4 hours [Device type] nanoe™ X Generator Mark 3, Internal unit: 4 way cassette.

Hydraulic solution for VRF projects.


· Water heat exchanger for chilled and hot water production. It’s ideal for hotel project. Maximum hot water outlet
temperature 45 °C with ECOi EX and 55 °C with ECO G
· Hydrokit for the medium water temperature application. Maximum hot water temperature 45 °C

41
GENERAL INDEX

VRF outdoor units range


Page Outdoor units 4 HP 5 HP 6 HP 8 HP 10 HP 12 HP

R32
P. 46
Mini ECOi LZ2
Series · R32
U-4LZ2E5 / U-4LZ2E8 U-5LZ2E5 / U-5LZ2E8 U-6LZ2E5 / U-6LZ2E8 U-8LZ2E8 U-10LZ2E8

Mini ECOi LE2 /


P. 47
LE1 Series · R410A

U-4LE2E5 / U-4LE2E8 U-5LE2E5 / U-5LE2E8 U-6LE2E5 / U-6LE2E8 U-8LE1E8 U-10LE1E8

R32

P. 49
NEW 2-Pipe
ECOi EX MZ1
Series · R32
U-8MZ1E8 U-10MZ1E8 U-12MZ1E8

2-Pipe ECOi EX
P. 51
ME2 Series · R410A

U-8ME2E8 U-10ME2E8 U-12ME2E8

3-Pipe ECOi EX
P. 53
MF3 Series · R410A

U-8MF3E8 U-10MF3E8 U-12MF3E8

2-Pipe ECO G GE3


P. 55
Series · R410A

3-Pipe ECO G GF3


P. 55
Series · R410A

GHP/EHP Hybrid
P. 55
System · R410A

42
VRF SYSTEMS INDEX VRF SYSTEMS

14 HP 16 HP 18 HP 20 HP 25 HP 30 HP

U-14ME2E8 U-16ME2E8 U-18ME2E8 U-20ME2E8

U-14MF3E8 U-16MF3E8

U-16GE3E5 U-20GE3E5 U-25GE3E5 U-30GE3E5

U-16GF3E5 U-20GF3E5 U-25GF3E5

U-20GES3E5 / U-10MES2E8

43
GENERAL INDEX

ECOi and ECO G indoor units range


Page Indoor units 1,0 kW 1,5 kW 2,2 kW 2,8 kW 3,6 kW 4,5 kW 5,6 kW

U2 type 4 way 90x90


P. 56
cassette · R32 / R410A
S-22MU2E5C S-28MU2E5C S-36MU2E5C S-45MU2E5C S-56MU2E5C

Y3 type 4 way 60x60


P. 56
cassette · R32 / R410A
S-15MY3EB S-22MY3EB S-28MY3EB S-36MY3EB S-45MY3EB S-56MY3EB

L1 type 2 way cassette


P. 57
· R410A
S-22ML1E5 S-28ML1E5 S-36ML1E5 S-45ML1E5 S- 56ML1E5

D1 type 1 way cassette


P. 57
· R410A
S-28MD1E5 S-36MD1E5 S-45MD1E5 S-56MD1E5

F3 type variable static


P. 58 pressure adaptive
duct · R32 / R410A S-15MF3E5D S-22MF3E5D S-28MF3E5D S-36MF3E5D S-45MF3E5D S-56MF3E5D

NEW M2 type slim


variable static
P. 58
pressure hide-away
· R32 / R410A S-10MM2EB S-15MM2EB S-22MM2EB S-28MM2EB S-36MM2EB S-45MM2EB S-56MM2EB

E2 type high static


P. 58 pressure hide-away
· R410A

T2 type ceiling
P. 59
· R410A
S-36MT2E5A S-45MT2E5A S-56MT2E5A

NEW K3 type wall-


P. 59 mounted · R32 /
R410A S-15MK3E S-22MK3E S-28MK3E S-36MK3E S-45MK3E S-56MK3E

G1 type floor console


P. 60
· R410A
S-22MG1E5N S-28MG1E5N S-36MG1E5N S-45MG1E5N S-56MG1E5N

P1 type floor-standing
P. 60
· R410A
S-22MP1E5 S-28MP1E5 S-36MP1E5 S-45MP1E5 S-56MP1E5

R1 type concealed
P. 60
floor-standing · R410A
S-22MR1E5 S-28MR1E5 S-36MR1E5 S-45MR1E5 S-56MR1E5

Hydrokit for ECOi,


P. 61
water at 45 °C · R410A

Energy recovery
ventilation with DX
P. 61
coil - HRPT Series
PAW-HRPT40HX PAW-HRPT80HX
· R32 / R410A PAW-HRPT40 (2,5 kW) PAW-HRPT80 (5 kW)

44
VRF SYSTEMS INDEX VRF SYSTEMS

OPTIONAL UNITS ON VENTILATION SECTION

6,0 kW 7,3 kW 9,0 kW 10,6 kW 11,2 kW 14,0 kW 16,0 kW 22,4 kW 28,0 kW

A new panel in graphite black


(RAL9011) is available.

S-60MU2E5C S-73MU2E5C S-90MU2E5C S-106MU2E5C S-112MU2E5C S-140MU2E5C S-160MU2E5C

S-73ML1E5

S-73MD1E5

S-60MF3E5D S-73MF3E5D S-90MF3E5D S-112MF3E5D S-140MF3E5D S-160MF3E5D

S-224ME2E5 S-280ME2E5

S-73MT2E5A S-106MT2E5A S-140MT2E5A

S-73MK3E S-106MK3E

S-71MP1E5

S-71MR1E5

S-80MW1E5 S-125MW1E5

PAW-HRPT120HX PAW-HRPT160HX PAW-HRPT200HX


PAW-HRPT120 (7 kW) PAW-HRPT160 (10 kW) PAW-HRPT200 (12,5 kW)

45
GENERAL INDEX

Mini VRF - Mini ECOi LZ2 Series R32


Mini ECOi LZ2 Series 4 to 6 HP · R32
R32
Outstanding seasonal efficiency.
Compact body - Low height only 996 mm.
Wide operation range from -20 °C in heating to +52 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
4 HP U-4LZ2E5 12,1 12,5 8,50 / 337,0% 5,05 / 199,0% 996 x 980 x 370 94 4,418
1ph 5 HP U-5LZ2E5 14,0 16,0 8,12 / 321,8% 4,61 / 181,4% 996 x 980 x 370 94 4,734
6 HP U-6LZ2E5 15,5 16,5 7,71 / 305,4% 4,59 / 180,6% 996 x 980 x 370 94 5,247
4 HP U-4LZ2E8 12,1 12,5 8,50 / 337,0% 5,05 / 199,0% 996 x 980 x 370 94 4,731
3ph 5 HP U-5LZ2E8 14,0 16,0 8,12 / 321,8% 4,61 / 181,4% 996 x 980 x 370 94 5,350
6 HP U-6LZ2E8 15,5 16,5 7,71 / 305,4% 4,59 / 180,6% 996 x 980 x 370 94 5,760

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 4 5 6 Single phase Three phase
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅝ ⅜-⅝ Outdoor unit HP 4 5 6 4 5 6
Maximum piping length (total) m 90 (180) 90 (180) 90 (180) Recommended fuse A 25 32 32 10 16 16
50 (OU above) / 50 (OU above) / 50 (OU above) /
Elevation difference (in / out) m
40 (OU below) 40 (OU below) 40 (OU below)

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values
of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

Mini ECOi LZ2 Series 8 and 10 HP · R32


R32
Outstanding seasonal efficiency.
Maximum piping length 100 m.
Wide operation range from -20 °C in heating to +52 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
8 HP U-8LZ2E8 22,4 25,0 7,56 / 299,4% 4,59 / 180,6% 1 500 x 980 x 370 125 7,504
3ph
10 HP U-10LZ2E8 28,0 28,0 7,08 / 280,2% 4,60 / 181,0% 1 500 x 980 x 370 126 8,229

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 8 10 Three phase
Piping diameter (liquid - gas) Inch ⅜-¾ ⅜-⅞ Outdoor unit HP 8 10
Maximum piping length (total) m 100 (300) 100 (300) Recommended fuse A 20 25
50 (OU above) / 50 (OU above) /
Elevation difference (in / out) m
40 (OU below) 40 (OU below)

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating
efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

R32 Pump Down solution.


R32 Pump Down solution offers the assurance
of additional safety protection, whilst expanding
the potential installation cases, allowing for
installation within smaller rooms.
Suitable for the Mini ECOi LZ2 range up to 10 HP, compatible indoor units connected to CZ-CGLSC2
or integrated Panasonic R32 refrigerant leak detector.

Model reference Description RRP £


Basic Pump Down system (2 way) for one R32 Mini ECOi
PAW-PUD2WB-1
outdoor unit

Leak detector designed for 4 way 90x90 cassettes, 4 way


CZ-CGLSC2
60x60 cassettes, and wall-mounted units.

46
VRF SYSTEMS INDEX VRF SYSTEMS

Mini VRF - Mini ECOi LE Series R410A


Mini ECOi LE2 Series high efficiency 4 to 6 HP · R410A
Ideal solution for the limited installation space.
Wide operation range from -20 °C in heating to +46 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
4 HP U-4LE2E5 12,1 12,5 7,85 / 311,0% 4,87 / 191,8% 996 x 980 x 370 106 4,167
1ph 5 HP U-5LE2E5 14,0 16,0 7,48 / 296,2% 4,40 / 172,9% 996 x 980 x 370 106 4,465
6 HP U-6LE2E5 15,5 16,5 7,25 / 286,8% 4,24 / 166,7% 996 x 980 x 370 106 4,950
4 HP U-4LE2E8 12,1 12,5 7,85 / 311,0% 4,87 / 191,8% 996 x 980 x 370 106 4,462
3ph 5 HP U-5LE2E8 14,0 16,0 7,48 / 296,2% 4,40 / 172,9% 996 x 980 x 370 106 5,047
6 HP U-6LE2E8 15,5 16,5 7,25 / 286,8% 4,24 / 166,7% 996 x 980 x 370 106 5,432

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 4 5 6 Single phase Three phase
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅝ ⅜-⅝ Outdoor unit HP 4 5 6 4 5 6
Maximum piping length (total) m 150 (180) 150 (180) 150 (180) Recommended fuse A 25 32 32 10 16 16
50 (OU above) / 50 (OU above) / 50 (OU above) /
Elevation difference (in / out) m
40 (OU below) 40 (OU below) 40 (OU below)

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating
efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

Mini ECOi LE1 Series high efficiency 8 and 10 HP · R410A


Ideal solution for the limited installation space.
Wide operation range from -20 °C in heating to +46 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
8 HP U-8LE1E8 22,4 25,0 6,27 / 247,9% 4,24 / 166,4% 1 500 x 980 x 370 132 7,078
3ph
10 HP U-10LE1E8 28,0 28,0 6,37 / 251,8% 4,31 / 169,5% 1 500 x 980 x 370 133 7,762

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 8 10 Three phase
Piping diameter (liquid - gas) Inch ⅜ 3) / ½ 4) - ¾ 3) / ⅞ 4) ⅜ 3) / ½ 4) - ⅞ 3) / 1 4) Outdoor unit HP 8 10
Maximum piping length (total) m 7,5 ~ 150 (7,5 ~ 300) 7,5 ~ 150 (7,5 ~ 300) Recommended fuse A 20 25
50 (OU above) / 50 (OU above) /
Elevation difference (in / out) m
40 (OU below) 40 (OU below)

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating
efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF. 3) Under 90 m for ultimate indoor unit. 4) Over 90 m for ultimate indoor unit. If the longest piping
equivalent length exceeds 90 m, increase the sizes of the main tubes by 1 rank for gas and liquid pipes.

Panasonic DX PRO Designer.


The Panasonic DX PRO Designer, rebuilt
with an improved user experience. The
software runs in the cloud and is always up to date
with the latest products. An intuitive interface
supports the most complicated designs, allows
online sharing and project collaboration with
multilingual support.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
47
GENERAL INDEX

New generation of 2-Pipe ECOi EX MZ1 Series R32


Extreme efficiency, quality, compact.
Panasonic provides safety measure compliant with the latest standards, as required based
on R32 refrigerant density under specific project conditions. Everything necessary for R32
refrigerant safety is prepared by Panasonic.

R32
REFRIGERANT

ηs,c ηs,h
R32
310,1% 2)
172,4% 2)

Reliable quality - R32 High seasonal More sustainable Saving installation Silent mode, maintaining
standard-compliant 1). efficiency. solution 3). space. high capacity.

52°C Max. 1 000 m 200


-25°C %

Extended operation Flexible piping Maximum indoor / Saving installation


range. installation. outdoor capacity ratio cost.
200%.
1) Panasonic’s R32 safety measures comply with IEC 60335-2-40 (ed. 7.0) and EN 378 (ISO 5149). 2) U-10MZ1E8. 3) Compared to R410A systems.

NEW
Extensive R32 range to meet any project
NEW
requirements.
· All air to air indoor units are equipped with nanoe™ X for
improved indoor air quality
· Hydronic modules options enable the production of heating /
hot water
· A range of ventilations including ERVs and AHU connection kits
· A wide range of connectivity options, including stand-alone, ERVs and AHU Hydronic
central, and remote monitoring, with BMS integration for connection kit modules

seamless operation

R32 safety measures by Panasonic.


Leak detector - Leak alarm - 2-pipe safety valve External power
CZ-CGLSC2. CZ-CGLALC1. kit - supply -
Leak detector designed R32 refrigerant leak CZ-P1160SVK. PAW-16DC-ALC1.
for 4 way 90x90 alarm designed for A 2-pipe safety valve External 16 V power
cassettes, 4 way 60x60 adaptive duct and slim manages the shutdown supply (EN 378
cassettes, and duct units. of only the area / zone compliant), including a
wall-mounted units. experiencing a leak alarm for remote
refrigerant leak, instead locations. The leak
of shutting down the alarm can be
whole system. deactivated.

48
VRF SYSTEMS INDEX VRF SYSTEMS

VRF - ECOi EX Series R32


NEW 2-Pipe ECOi EX MZ1 Series · R32
R32 New 2025
Extreme efficiency, quality, compact.
Advanced R32 refrigerant technology and optimised system design.
Wide operation range from -25 °C in heating to +52 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
8 HP U-8MZ1E8 22,4 25,0 7,27 / 288,0% 4,35 / 171,0% 1 660 x 880 x 765 203 9,283
3ph 10 HP U-10MZ1E8 28,0 31,5 7,82 / 310,1% 4,38 / 172,4% 1 660 x 880 x 765 203 9,964
12 HP U-12MZ1E8 33,5 37,5 7,37 / 292,1% 4,33 / 170,3% 1 660 x 880 x 765 206 11,940

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 8 10 12 Three phase
Piping diameter (liquid) Inch ⅜-½ ⅜-½ ⅜-½ Outdoor unit HP 8 10 12
Piping diameter (gas) Inch ¾/⅞ ¾/⅞ ⅞ / 1⅛ Recommended fuse A 20 25 25
Piping diameter (balance) Inch ¼ ¼ ¼

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values
of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

NEW 2-Pipe ECOi EX MZ1 Series


combination from 16 to 48 HP · R32 R32 New 2025

Outdoor unit Nominal capacity SEER 2) / ηs,c SCOP 2) / ηs,h Dimension Weight RRP
Cooling Heating HxWxD
kW kW mm kg £
16 HP U-8MZ1E8 + U-8MZ1E8 44,8 50,0 7,24 / 286,8% 4,32 / 169,8% 1 660 x 1 760 (+60) x 765 406 18,566
18 HP U-8MZ1E8 + U-10MZ1E8 50,4 56,5 7,56 / 299,6% 4,33 / 170,3% 1 660 x 1 760 (+60) x 765 406 19,247
20 HP U-8MZ1E8 + U-12MZ1E8 55,9 62,5 7,29 / 288,9% 4,29 / 168,8% 1 660 x 1 760 (+60) x 765 409 21,223
20 HP U-10MZ1E8 + U-10MZ1E8 56,0 63,0 7,82 / 310,1% 4,38 / 172,2% 1 660 x 1 760 (+60) x 765 406 19,928
22 HP U-10MZ1E8 + U-12MZ1E8 61,5 69,0 7,55 / 299,1% 4,34 / 170,7% 1 660 x 1 760 (+60) x 765 409 21,904
24 HP U-12MZ1E8 + U-12MZ1E8 67,0 75,0 7,33 / 290,2% 4,33 / 170,2% 1 660 x 1 760 (+60) x 765 412 23,880
24 HP U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8 67,2 75,0 7,24 / 286,8% 4,32 / 169,8% 1 660 x 2 640 (+120) x 765 609 27,849
26 HP U-8MZ1E8 + U-8MZ1E8 + U-10MZ1E8 72,8 81,5 7,46 / 295,6% 4,31 / 169,5% 1 660 x 2 640 (+120) x 765 609 28,530
28 HP U-8MZ1E8 + U-8MZ1E8 + U-12MZ1E8 78,3 87,5 7,23 / 286,3% 4,34 / 170,9% 1 660 x 2 640 (+120) x 765 612 30,506
28 HP U-8MZ1E8 + U-10MZ1E8 + U-10MZ1E8 78,4 88,0 7,61 / 301,5% 4,35 / 171,2% 1 660 x 2 640 (+120) x 765 609 29,211
30 HP U-8MZ1E8 + U-10MZ1E8 + U-12MZ1E8 83,9 94,0 7,45 / 295,1% 4,33 / 170,4% 1 660 x 2 640 (+120) x 765 612 31,187
30 HP U-10MZ1E8 + U-10MZ1E8 + U-10MZ1E8 84,0 94,5 7,82 / 310,1% 4,38 / 172,4% 1 660 x 2 640 (+120) x 765 609 29,892
32 HP U-8MZ1E8 + U-12MZ1E8 + U-12MZ1E8 89,4 100,0 7,26 / 287,4% 4,31 / 169,6% 1 660 x 2 640 (+120) x 765 615 33,163
32 HP U-10MZ1E8 + U-10MZ1E8 + U-12MZ1E8 89,5 100,0 7,63 / 302,4% 4,38 / 172,2% 1 660 x 2 640 (+120) x 765 612 31,868
32 HP U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8 89,6 100,0 7,24 / 286,8% 4,32 / 169,8% 1 660 x 3 520 (+180) x 765 812 37,132
3ph 34 HP U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 95,0 106,0 7,47 / 295,9% 4,35 / 171,3% 1 660 x 2 640 (+120) x 765 615 33,844
34 HP U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8 + U-10MZ1E8 95,2 106,0 7,37 / 291,8% 4,29 / 168,7% 1 660 x 3 520 (+180) x 765 812 37,813
36 HP U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 100,0 112,0 7,37 / 292,0% 4,33 / 170,3% 1 660 x 2 640 (+120) x 765 618 35,820
36 HP U-8MZ1E8 + U-8MZ1E8 + U-10MZ1E8 + U-10MZ1E8 100,0 113,0 7,53 / 298,2% 4,33 / 170,3% 1 660 x 3 520 (+180) x 765 812 38,494
36 HP U-8MZ1E8 + U-8MZ1E8 + U-8MZ1E8 + U-12MZ1E8 100,0 112,0 7,25 / 287,0% 4,32 / 170,1% 1 660 x 3 520 (+180) x 765 815 39,789
38 HP U-8MZ1E8 + U-8MZ1E8 + U-10MZ1E8 + U-12MZ1E8 106,0 119,0 7,36 / 291,7% 4,31 / 169,6% 1 660 x 3 520 (+180) x 765 815 40,470
38 HP U-8MZ1E8 + U-10MZ1E8 + U-10MZ1E8 + U-10MZ1E8 106,0 119,0 7,66 / 303,4% 4,36 / 171,4% 1 660 x 3 520 (+180) x 765 812 39,175
40 HP U-8MZ1E8 + U-8MZ1E8 + U-12MZ1E8 + U-12MZ1E8 111,0 125,0 7,30 / 289,0% 4,29 / 168,8% 1 660 x 3 520 (+180) x 765 818 42,446
40 HP U-10MZ1E8 + U-10MZ1E8 + U-10MZ1E8 + U-10MZ1E8 112,0 126,0 7,82 / 310,1% 4,38 / 172,2% 1 660 x 3 520 (+180) x 765 812 39,856
40 HP U-8MZ1E8 + U-10MZ1E8 + U-10MZ1E8 + U-12MZ1E8 111,0 125,0 7,53 / 298,2% 4,34 / 170,6% 1 660 x 3 520 (+180) x 765 815 41,151
42 HP U-8MZ1E8 + U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 117,0 131,0 7,43 / 294,4% 4,35 / 171,0% 1 660 x 3 520 (+180) x 765 818 43,127
42 HP U-10MZ1E8 + U-10MZ1E8 + U-10MZ1E8 + U-12MZ1E8 117,0 132,0 7,65 / 303,2% 4,36 / 171,6% 1 660 x 3 520 (+180) x 765 815 41,832
44 HP U-8MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 122,0 137,0 7,28 / 288,5% 4,33 / 170,3% 1 660 x 3 520 (+180) x 765 821 45,103
44 HP U-10MZ1E8 + U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 123,0 138,0 7,56 / 299,4% 4,34 / 170,7% 1 660 x 3 520 (+180) x 765 818 43,808
46 HP U-10MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 128,0 144,0 7,41 / 293,7% 4,35 / 171,2% 1 660 x 3 520 (+180) x 765 821 45,784
48 HP U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 + U-12MZ1E8 134,0 150,0 7,37 / 292,1% 4,33 / 170,3% 1 660 x 3 520 (+180) x 765 824 47,760

Piping information
Outdoor unit HP 16 HP 18 HP 20 HP 20 HP 22 HP 24 HP 24 HP 26 HP 28 HP 28 HP 30 HP 30 HP 32 HP 32 HP 32 HP 34 HP
Piping diameter (liquid) Inch ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ½/⅝ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾
Piping diameter (gas) Inch 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Outdoor unit HP 34 HP 36 HP 36 HP 36 HP 38 HP 38 HP 40 HP 40 HP 40 HP 42 HP 42 HP 44 HP 44 HP 46 HP 48 HP
Piping diameter (liquid) Inch ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾
Piping diameter (gas) Inch 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

1) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF. SEER / SCOP and
ηs,c / ηs,h are in accordance with ErP test data for U2 type 4 way 90x90 cassette indoor units.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
49
GENERAL INDEX

ECOi EX Series R410A


VRF with outstanding energy-saving performance and powerful
operation SEER 7,56 (2-Pipe 18 HP model).

The ECOi EX Series delivers energy-saving performance, powerful operation, exceptional reliability, and
comfort that surpasses anything previously possible.

52°C
-25°C

High performance at extreme Outstanding efficiency and comfort. Superior flexibility.


conditions. The ECOi EX system is designed to ECOi EX, the ideal air conditioning
The units can operate at 100% of increase energy efficiency by option for expansive buildings, such
capacity at 43 °C, reaching a great delivering high SEER rating, as well as train stations, airports, schools or
cooling operation up to 52 °C and in as high efficiency for part-load hospitals.
heating to -25 °C*. operation.
* Conditions of 2-Pipe ECOi EX ME2 Series.

50
VRF SYSTEMS INDEX VRF SYSTEMS

VRF - ECOi EX Series R410A


2-Pipe ECOi EX ME2 Series · R410A
High performance at extreme conditions.
Oil recovery intelligent control for high performance and comfort.
Wide operation range from -25 °C in heating to +52 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
8 HP U-8ME2E8 22,4 25,0 7,43 / 294,3% 4,79 / 188,4% 1 842 x 770 x 1 000 210 9,022
10 HP U-10ME2E8 28,0 31,5 6,96 / 275,4% 4,27 / 167,6% 1 842 x 770 x 1 000 210 9,685
12 HP U-12ME2E8 33,5 37,5 6,74 / 266,6% 4,72 / 185,8% 1 842 x 1 180 x 1 000 270 11,605
3ph 14 HP U-14ME2E8 40,0 45,0 7,23 / 286,0% 4,28 / 168,2% 1 842 x 1 180 x 1 000 315 13,074
16 HP U-16ME2E8 45,0 50,0 6,43 / 254,3% 4,05 / 159,0% 1 842 x 1 180 x 1 000 315 14,129
18 HP U-18ME2E8 50,0 56,0 7,56 / 299,2% 4,29 / 168,7% 1 842 x 1 540 x 1 000 375 16,227
20 HP U-20ME2E8 56,0 63,0 7,03 / 278,2% 4,09 / 160,4% 1 842 x 1 540 x 1 000 375 17,049

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 8 10 12 14 16 18 20 Three phase
Piping diameter (liquid) Inch ⅜-½ ⅜-½ ½/⅝ ½/⅝ ½/⅝ ⅝/¾ ⅝/¾ Outdoor unit HP 8 10 12 14 16 18 20
Piping diameter (gas) Inch ¾/⅞ ⅞ / 1⅛ 1⅛ 1⅛ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ Recommended fuse A 16 20 25 32 40 40 50
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating
efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

2-Pipe ECOi EX ME2 Series · R410A


High efficiency model combination from 18 to 64 HP

Outdoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
18 HP U-8ME2E8 + U-10ME2E8 50,0 56,0 1 842 x 1 600 x 1 000 420 9,022
20 HP U-10ME2E8 + U-10ME2E8 56,0 63,0 1 842 x 1 600 x 1 000 420 9,685
22 HP U-10ME2E8 + U-12ME2E8 61,5 69,0 1 842 x 2 010 x 1 000 480 11,605
24 HP U-12ME2E8 + U-12ME2E8 68,0 76,5 1 842 x 2 420 x 1 000 540 13,074
26 HP U-10ME2E8 + U-16ME2E8 73,0 81,5 1 842 x 2 010 x 1 000 535 14,129
28 HP U-12ME2E8 + U-16ME2E8 78,5 87,5 1 842 x 2 420 x 1 000 585 18,707
30 HP U-14ME2E8 + U-16ME2E8 85,0 95,0 1 842 x 2 420 x 1 000 630 19,370
32 HP U-16ME2E8 + U-16ME2E8 90,0 100,0 1 842 x 2 420 x 1 000 630 21,290
34 HP U-10ME2E8 + U-12ME2E8 + U-12ME2E8 96,0 108,0 1 842 x 3 250 x 1 000 750 23,210
36 HP U-12ME2E8 + U-12ME2E8 + U-12ME2E8 101,0 113,0 1 842 x 3 660 x 1 000 810 23,814
38 HP U-10ME2E8 + U-12ME2E8 + U-16ME2E8 107,0 119,0 1 842 x 3 250 x 1 000 795 25,734
40 HP U-12ME2E8 + U-12ME2E8 + U-16ME2E8 113,0 127,0 1 842 x 3 660 x 1 000 855 27,203
3ph
42 HP U-10ME2E8 + U-16ME2E8 + U-16ME2E8 118,0 132,0 1 842 x 3 250 x 1 000 840 28,258
44 HP U-12ME2E8 + U-16ME2E8 + U-16ME2E8 124,0 138,0 1 842 x 3 660 x 1 000 900 39,863
46 HP U-14ME2E8 + U-16ME2E8 + U-16ME2E8 130,0 145,0 1 842 x 3 660 x 1 000 945 41,332
48 HP U-16ME2E8 + U-16ME2E8 + U-16ME2E8 135,0 150,0 1 842 x 3 660 x 1 000 945 42,387
50 HP U-10ME2E8 + U-12ME2E8 + U-12ME2E8 + U-16ME2E8 140,0 155,0 1 842 x 4 490 x 1 000 1 065 47,024
52 HP U-12ME2E8 + U-12ME2E8 + U-12ME2E8 + U-16ME2E8 145,0 160,0 1 842 x 4 900 x 1 000 1 125 48,944
54 HP U-10ME2E8 + U-12ME2E8 + U-16ME2E8 + U-16ME2E8 151,0 169,0 1 842 x 4 490 x 1 000 1 110 49,548
56 HP U-12ME2E8 + U-12ME2E8 + U-16ME2E8 + U-16ME2E8 156,0 175,0 1 842 x 4 900 x 1 000 1 170 51,468
58 HP U-10ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 162,0 182,0 1 842 x 4 490 x 1 000 1 155 52,072
60 HP U-12ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 168,0 189,0 1 842 x 4 900 x 1 000 1 215 53,992
62 HP U-14ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 174,0 195,0 1 842 x 4 900 x 1 000 1 260 55,461
64 HP U-16ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 180,0 201,0 1 842 x 4 900 x 1 000 1 260 56,516

Piping information
Outdoor unit HP 18 20 22 24 26 28 30 32 34 36 38 40
Piping diameter (liquid) Inch ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞
Piping diameter (gas) Inch 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅝ 1⅝ 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Outdoor unit HP 42 44 46 48 50 52 54 56 58 60 62 64
Piping diameter (liquid) Inch ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞
Piping diameter (gas) Inch 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1½ / 1⅝ 1⅝/ 1 ¾ 1⅝/ 2 ⅛
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
51
GENERAL INDEX

VRF - ECOi EX Series R410A


2-Pipe ECOi EX ME2 Series · R410A
Space saving model combination from 22 to 80 HP

Outdoor unit Nominal capacity SEER 1) SCOP 1) Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
22 HP U-10ME2E8 + U-12ME2E8 61,5 69,0 6,90 4,53 1 842 x 2 010 x 1 000 480 21,290
24 HP U-12ME2E8 + U-12ME2E8 68,0 76,5 6,86 4,78 1 842 x 2 420 x 1 000 540 23,210
26 HP U-10ME2E8 + U-16ME2E8 73,0 81,5 6,62 4,16 1 842 x 2 010 x 1 000 525 23,814
28 HP U-12ME2E8 + U-16ME2E8 78,5 87,5 6,60 4,29 1 842 x 2 420 x 1 000 585 25,734
30 HP U-14ME2E8 + U-16ME2E8 85,0 95,0 6,88 4,13 1 842 x 2 420 x 1 000 630 27,203
32 HP U-16ME2E8 + U-16ME2E8 90,0 100,0 6,55 4,09 1 842 x 2 420 x 1 000 630 28,258
34 HP U-14ME2E8 + U-20ME2E8 96,0 108,0 7,21 4,14 1 842 x 2 780 x 1 000 690 30,123
36 HP U-16ME2E8 + U-20ME2E8 101,0 113,0 6,86 4,06 1 842 x 2 780 x 1 000 690 31,178
38 HP U-18ME2E8 + U-20ME2E8 107,0 119,0 7,32 4,14 1 842 x 3 140 x 1 000 750 33,276
40 HP U-20ME2E8 + U-20ME2E8 113,0 127,0 7,16 4,13 1 842 x 3 140 x 1 000 750 34,098
42 HP U-10ME2E8 + U-16ME2E8 + U-16ME2E8 118,0 132,0 6,57 4,11 1 842 x 3 250 x 1 000 840 37,943
44 HP U-12ME2E8 + U-16ME2E8 + U-16ME2E8 124,0 138,0 6,60 4,21 1 842 x 3 660 x 1 000 900 39,863
46 HP U-14ME2E8 + U-16ME2E8 + U-16ME2E8 130,0 145,0 6,70 4,12 1 842 x 3 660 x 1 000 945 41,332
48 HP U-16ME2E8 + U-16ME2E8 + U-16ME2E8 135,0 150,0 6,55 4,09 1 842 x 3 660 x 1 000 945 42,387
50 HP U-14ME2E8 + U-16ME2E8 + U-20ME2E8 140,0 155,0 6,96 4,08 1 842 x 4 020 x 1 000 1 005 44,252
3ph
52 HP U-16ME2E8 + U-16ME2E8 + U-20ME2E8 145,0 160,0 6,72 4,05 1 842 x 4 020 x 1 000 1 005 45,307
54 HP U-14ME2E8 + U-20ME2E8 + U-20ME2E8 151,0 169,0 7,16 4,13 1 842 x 4 380 x 1 000 1 065 47,172
56 HP U-16ME2E8 + U-20ME2E8 + U-20ME2E8 156,0 175,0 6,92 4,07 1 842 x 4 380 x 1 000 1 065 48,227
58 HP U-18ME2E8 + U-20ME2E8 + U-20ME2E8 162,0 182,0 7,30 4,13 1 842 x 4 740 x 1 000 1 125 50,325
60 HP U-20ME2E8 + U-20ME2E8 + U-20ME2E8 168,0 189,0 7,16 4,13 1 842 x 4 740 x 1 000 1 125 51,147
62 HP U-14ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 174,0 195,0 6,68 4,11 1 842 x 4 900 x 1 000 1 260 55,461
64 HP U-16ME2E8 + U-16ME2E8 + U-16ME2E8 + U-16ME2E8 180,0 201,0 6,55 4,09 1 842 x 4 900 x 1 000 1 260 56,516
66 HP U-10ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8 185,0 207,0 6,92 4,11 1 842 x 5 210 x 1 000 1 275 57,912
68 HP U-12ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8 190,0 213,0 6,91 4,17 1 842 x 5 620 x 1 000 1 335 59,832
70 HP U-10ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8 196,0 219,0 7,09 4,13 1 842 x 5 570 x 1 000 1 335 60,832
72 HP U-16ME2E8 + U-16ME2E8 + U-20ME2E8 + U-20ME2E8 202,0 226,0 6,86 4,06 1 842 x 5 620 x 1 000 1 380 62,356
74 HP U-16ME2E8 + U-18ME2E8 + U-20ME2E8 + U-20ME2E8 208,0 233,0 7,03 4,12 1 842 x 5 980 x 1 000 1 440 64,454
76 HP U-16ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8 213,0 239,0 7,01 4,07 1 842 x 5 980 x 1 000 1 440 65,276
78 HP U-18ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8 219,0 245,0 7,18 4,13 1 842 x 6 340 x 1 000 1 500 67,374
80 HP U-20ME2E8 + U-20ME2E8 + U-20ME2E8 + U-20ME2E8 224,0 252,0 7,16 4,13 1 842 x 6 340 x 1 000 1 500 68,196

Piping information
Outdoor unit HP 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50
Piping diameter (liquid) Inch ⅝/¾ ⅝/¾ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞
Piping diameter (gas) Inch 1⅛ / 1¼ 1⅛ / 1¼ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅜ / 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Outdoor unit HP 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80
Piping diameter (liquid) Inch ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ⅞ / 1⅛ ⅞ / 1⅛ ⅞ / 1⅛ ⅞ / 1⅛ ⅞ / 1⅛ ⅞ / 1⅛ ⅞ / 1⅛
Piping diameter (gas) Inch 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ / 2⅛ 1⅝ / 2⅛ 2⅛ 1⅝ / 2⅛ 2⅛ 2⅛ 2⅛ 2⅛ 2⅛
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

1) SEER / SCOP is calculated based on the seasonal space cooling / heating efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

ECOi 2-Pipe with water heat exchanger for chilled and hot water production
Flexible modularity from 25 kW.
Maximum hot water outlet temperature: 45 °C.
Minimum chilled water outlet temperature: 5 °C.

Hydrokit Outdoor unit RRP


Nominal Energy ηs,h Dimension / Weight Dimension / Weight w w/o Outdoor
capacity efficiency (LOT21) 2) (with pump) pump pump
class at HxWxD
With A class Without pump Cool Heat HxWxD
35 °C 1)
water pump kW kW mm / kg mm / kg £ £ £
1 000 x 575 x 1 110 / 1 842 x 770 x 1 000 /
25 kW PAW-250WP5G1 PAW-250W5G1 25,0 28,0 A++ 152,00% U-10ME2E8 9,685
135 (140) 210 14,273 13,560
1ph
1 000 x 575 x 1 110 / 1 842 x 1 540 x 1 000 /
50 kW PAW-500WP5G1 PAW-500W5G1 50,0 56,0 A++ 152,00% U-20ME2E8 17,049
155 (165) 375 15,095 14,341

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 25 50 Three phase
Piping diameter (liquid - gas) Inch ⅜-⅞ ⅝ - 1⅛ Outdoor unit kW 25 50
Elevation difference (in / out) m 50 (OU above) / 35 (OU below) 50 (OU above) / 35 (OU below) Recommended fuse A 16 16
Pre-charged pipe length m 0< 0<
Additional gas amount g/m Refer to manual Refer to manual

1) Unit efficiency energy level: Scale from A+++ to D. 2) Seasonal space cooling / heating energy efficiency following COMMISSION REGULATION (EU) 813/2013.

52
VRF SYSTEMS INDEX VRF SYSTEMS

VRF - ECOi EX Series R410A


3-Pipe ECOi EX MF3 Series · R410A
Simultaneous heating and cooling operation with heat recovery.
Slim heat recovery boxes with just 200 mm height.
Wide operation range from -20 °C in heating to +52 °C in cooling.

Outdoor unit Nominal capacity ErP data 1) Dimension Weight RRP


Cooling Heating SEER 2) / ηs,c SCOP 2) / ηs,h HxWxD
kW kW mm kg £
8 HP U-8MF3E8 22,4 25,0 7,02 / 277,7% 4,85 / 190,9% 1 842 x 1 180 x 1 000 261 9,144
10 HP U-10MF3E8 28,0 31,5 7,05 / 278,9% 4,25 / 166,8% 1 842 x 1 180 x 1 000 262 10,092
3ph 12 HP U-12MF3E8 33,5 37,5 6,39 / 252,7% 4,27 / 167,8% 1 842 x 1 180 x 1 000 286 11,662
14 HP U-14MF3E8 40,0 45,0 6,69 / 264,4% 4,13 / 162,1% 1 842 x 1 180 x 1 000 334 13,489
16 HP U-16MF3E8 45,0 50,0 6,02 / 237,7% 3,81 / 149,3% 1 842 x 1 180 x 1 000 334 15,501

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 8 10 12 14 16 Three phase
Piping diameter (liquid) Inch ⅜/½ ⅜/½ ½/⅝ ½/⅝ ½/⅝ Outdoor unit HP 8 10 12 14 16
Piping diameter (discharge) Inch ⅝/¾ ¾/⅞ ¾/⅞ ⅞ / 1⅛ ⅞ / 1⅛ Recommended fuse A 20 25 25 40 40
Piping diameter (suction) Inch ¾/⅞ ⅞ / 1⅛ 1⅛ 1 / 1⅛ 1⅛ / 1 ⅜
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼

1) SEER / SCOP and ηs,c / ηs,h are in accordance with ErP test data for F2 type variable static pressure hide-away indoor units. 2) SEER / SCOP is calculated based on the seasonal space cooling / heating
efficiency “η” values of the COMMISSION REGULATION (EU) 2016/2281. SEER, SCOP = (η + Correction) × PEF.

3-Pipe ECOi EX MF3 Series · R410A


Combination from 18 to 48 HP

Outdoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
18 HP U-8MF3E8 + U-10MF3E8 50,0 56,0 1 842 x 2 360 (+60) x 1 000 523 19,236
20 HP U-8MF3E8 + U-12MF3E8 56,0 63,0 1 842 x 2 360 (+60) x 1 000 547 20,806
22 HP U-10MF3E8 + U-12MF3E8 61,5 69,0 1 842 x 2 360 (+60) x 1 000 548 21,754
24 HP U-12MF3E8 + U-12MF3E8 68,0 76,5 1 842 x 2 360 (+60) x 1 000 574 23,324
26 HP U-10MF3E8 + U-16MF3E8 73,0 81,5 1 842 x 2 360 (+60) x 1 000 596 25,593
28 HP U-12MF3E8 + U-16MF3E8 78,5 87,5 1 842 x 2 360 (+60) x 1 000 620 27,163
30 HP U-14MF3E8 + U-16MF3E8 85,0 95,0 1 842 x 2 360 (+60) x 1 000 668 28,990
32 HP U-16MF3E8 + U-16MF3E8 90,0 100,0 1 842 x 2 360 (+60) x 1 000 668 31,002
3ph
34 HP U-8MF3E8 + U-10MF3E8 + U-16MF3E8 96,0 108,0 1 842 x 3 540 (+120) x 1 000 857 34,737
36 HP U-8MF3E8 + U-12MF3E8 + U-16MF3E8 101,0 113,0 1 842 x 3 540 (+120) x 1 000 881 36,307
38 HP U-10MF3E8 + U-12MF3E8 + U-16MF3E8 107,0 119,0 1 842 x 3 540 (+120) x 1 000 882 37,255
40 HP U-8MF3E8 + U-16MF3E8 + U-16MF3E8 113,0 127,0 1 842 x 3 540 (+120) x 1 000 929 40,146
42 HP U-10MF3E8 + U-16MF3E8 + U-16MF3E8 118,0 132,0 1 842 x 3 540 (+120) x 1 000 930 41,094
44 HP U-12MF3E8 + U-16MF3E8 + U-16MF3E8 124,0 138,0 1 842 x 3 540 (+120) x 1 000 954 42,664
46 HP U-14MF3E8 + U-16MF3E8 + U-16MF3E8 130,0 145,0 1 842 x 3 540 (+120) x 1 000 1 002 44,491
48 HP U-16MF3E8 + U-16MF3E8 + U-16MF3E8 135,0 150,0 1 842 x 3 540 (+120) x 1 000 1 002 46,503

Piping information
Outdoor unit HP 18 20 22 24 26 28 30 32
Piping diameter (liquid) Inch ⅝/¾ ⅝/¾ ⅝/¾ ⅝/¾ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞
Piping diameter (discharge) Inch ⅞ / 1⅛ ⅞ / 1⅛ 1⅛ 1⅛ 1⅛ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜
Piping diameter (suction) Inch 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Outdoor unit HP 34 36 38 40 42 44 46 48
Piping diameter (liquid) Inch ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞ ¾/⅞
Piping diameter (discharge) Inch 1⅛ / 1⅜ 1⅛ / 1⅜ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝ 1⅜/ 1⅝
Piping diameter (suction) Inch 1⅜/ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝ 1⅝
Piping diameter (balance) Inch ¼ ¼ ¼ ¼ ¼ ¼ ¼ ¼

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
53
GENERAL INDEX

Gas driven VRF - ECO G Series R410A


2-Pipe ECO G GE3 Series
A perfect solution for the project location with lack of electricity.
Quick start up and high heating capacity at low ambient temperature.
Operation range from -21 °C in heating to +43 °C in cooling.

Outdoor unit Nominal capacity ηs,c (LOT21) 1) ηs,h (LOT21) 1) Dimension Weight RRP
Cooling Heating HxWxD
kW kW mm kg £
16 HP U-16GE3E5 45,0 50,0 220,60% 150,60% 2 255 x 1 650 x 1 000 765 37,890
20 HP U-20GE3E5 56,0 63,0 219,30% 143,70% 2 255 x 1 650 x 1 000 765 43,185
1ph
25 HP U-25GE3E5 71,0 80,0 240,10% 146,90% 2 255 x 2 026 x 1 000 870 46,137
30 HP U-30GE3E5 85,0 95,0 229,30% 151,30% 2 255 x 2 026 x 1 000 880 51,560

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 16 20 25 30 Single phase
Piping diameter (liquid - gas) Inch ½ - 1⅛ ⅝ - 1⅛ ⅝ - 1⅛ ¾ - 1⅜ Outdoor unit HP 16 20 25 30
Piping diameter (fuel gas) Inch ¾ ¾ ¾ ¾ Recommended fuse A 16 16 16 16
Piping diameter (exhaust drain port) mm 25 25 25 25
Piping diameter (hot water supply in/out) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread)
Elevation difference (in / out) m 50 50 50 50

1) ErP test data.

2-Pipe ECO G GE3 Series combination from 32 to 60 HP

Outdoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
32 HP U-16GE3E5 + U-16GE3E5 90,0 100,0 2 255 x 1 650 + 100 + 1 650 x 1 000 1 530 (765 + 765) 75,780
36 HP U-16GE3E5 + U-20GE3E5 101,0 113,0 2 255 x 1 650 + 100 + 1 650 x 1 000 1 530 (765 + 765) 81,075
40 HP U-20GE3E5 + U-20GE3E5 112,0 126,0 2 255 x 1 650 + 100 + 1 650 x 1 000 1 530 (765 + 765) 86,370
1ph 45 HP U-20GE3E5 + U-25GE3E5 127,0 143,0 2 255 x 1 650 + 100 + 2 026 x 1 000 1 635 (765 + 870) 89,322
50 HP U-25GE3E5 + U-25GE3E5 142,0 160,0 2 255 x 2 026 + 100 + 2 026 x 1 000 1 740 (870 + 870) 92,274
55 HP U-25GE3E5 + U-30GE3E5 156,0 175,0 2 255 x 2 026 + 100 + 2 026 x 1 000 1 750 (870 + 880) 97,697
60 HP U-30GE3E5 + U-30GE3E5 170,0 190,0 2 255 x 2 026 + 100 + 2 026 x 1 000 1 760 (880 + 880) 103,120

Piping information
Outdoor unit HP 32 36 40 45 50 55 60
Piping diameter (liquid - gas) Inch ¾ - 1⅜ ¾ - 1⅜ ¾ - 1⅝ ¾ - 1⅝ ¾ - 1⅝ ⅞ - 1⅝ ⅞ - 1⅝
Piping diameter (fuel gas) Inch ¾ ¾ ¾ ¾ ¾ ¾ ¾
Piping diameter (exhaust drain port) mm 25 25 25 25 25 25 25
Piping diameter (hot water supply in/out) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread)
Elevation difference (in / out) m 50 50 50 50 50 50 50

Smart multi-site control solution.


Modern and scalable energy management for
your Heating & Cooling Solutions.
With a simple click, all your units from several
locations, receive status updates in real-time
preventing breakdowns and optimising costs.

DETAILED REFERENCES IS IN PAGE 65

Installation. Connectivity. Reliability. Use. Roles and permission. Security.


Easy installation and configuration. A standard LAN connection with 24/7/365 days connection. Real-time control from anywhere. Easily configure different access Highly secure communication and
internet access (fibre or mobile). roles for each user. complaint with GDPR.

54
VRF SYSTEMS INDEX VRF SYSTEMS

Gas driven VRF - ECO G Series R410A


3-Pipe ECO G GF3 Series
A perfect solution for the project location with lack of electricity.
Free DHW (Domestic Hot Water) production available in all seasons.
Operation range from -21 °C in heating to +43 °C in cooling.

Outdoor unit Nominal capacity ηs,c (LOT21) 1) ηs,h (LOT21) 1) Dimension Weight RRP
Cooling Heating HxWxD
kW kW mm kg £
16 HP U-16GF3E5 45,0 50,0 185,20% 139,20% 2 255 x 1 650 x 1 000 775 40,195
1ph 20 HP U-20GF3E5 56,0 63,0 198,80% 140,20% 2 255 x 1 650 x 1 000 775 44,662
25 HP U-25GF3E5 71,0 80,0 204,90% 150,90% 2 255 x 2 026 x 1 000 880 48,372

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 16 20 25 Single phase
Piping diameter (liquid - gas) Inch ¾ - 1⅛ ¾ - 1⅛ ¾ - 1⅛ Outdoor unit HP 16 20 25
Piping diameter (discharge) Inch ⅞ 1⅛ 1⅛ Recommended fuse A 16 16 16
Piping diameter (fuel gas) Inch ¾ ¾ ¾
Piping diameter (exhaust drain port) mm 25 25 25
Piping diameter (hot water supply in/out) Rp¾ (Nut, thread) Rp¾ (Nut, thread) Rp¾ (Nut, thread)
Elevation difference (in / out) m 50 50 50

1) ErP test data.

2-Pipe Hybrid GHP/EHP


Intelligent technology taking advantage of Gas and Electricity to achieve better energy savings.
Long lifespan thanks to the optimal performance between GHP and EHP.
Operation range from -21 °C in heating to +43 °C in cooling.

Outdoor unit Nominal capacity ηs,c (LOT21) ηs,h (LOT21) Dimension Weight RRP
Cooling Heating HxWxD
kW kW mm kg £
1ph 20 HP Hybrid GHP U-20GES3E5 56,0 63,0 211,80% 143,20% 2 255 x 1 650 x 1 000 765 45,002
3ph 10 HP Hybrid EHP U-10MES2E8 28,0 31,5 275,40% 167,60% 1 842 x 770 x 1 000 210 11,619

Piping information Electrical information (power supply to indoor)


Outdoor unit HP 20 10 Single phase Three phase
Piping diameter (liquid - gas) Inch ⅝ - 1⅛ ⅜-⅞ Outdoor unit HP 20 10
Piping diameter (balance) Inch ¼ ¼ Recommended fuse A 16 25
Elevation difference (in / out) m — —

ECO G with water heat exchanger for chilled and hot water production
Free DHW from waste heat of engine.
Hot water outlet temperatures from 35 to 55 °C.
Chilled water outlet temperatures from -15 to +15 °C.

Hydrokit Outdoor unit RRP


Nominal Energy ηs,h Dimension / Weight Dimension / Weight w w/o Outdoor
capacity efficiency (LOT21) 2) (with pump) pump pump
class at HxWxD
With A class Without pump Cool Heat HxWxD
35 °C 1)
water pump kW kW mm / kg mm / kg £ £ £
1 000 x 575 x 1 110 2 255 x 1 650 x 1 000
50 kW PAW-500WP5G1 PAW-500W5G1 50,0 60,0 A+ 130,00% U-20GE3E5 43,185
/ 155 (165) / 765 15,095 14,341
1ph
1 000 x 575 x 1 110 2 255 x 2 026 x 1 000
71 kW PAW-710WP5G1 PAW-710W5G1 67,0 80,0 — 128,00% U-30GE3E5 51,560
/ 160 (175) / 880 17,361 16,492

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 50 71 Single phase
Piping diameter (liquid - gas) Inch ⅝ - 1⅛ ¾ - 1⅜ Outdoor unit kW 50 71
Elevation difference (in / out) m 50 (OU above) / 35 (OU below) 50 (OU above) / 35 (OU below) Recommended fuse A 16 16

1) Unit efficiency energy level: Scale from A+++ to D. 2) ErP test data. Seasonal space cooling / heating energy efficiency following COMMISSION REGULATION (EU) 813/2013.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
55
GENERAL INDEX

VRF Systems indoor units


U2 type 4 way 90x90 cassette · R32 / R410A Standard panel.
White (RAL9003): CZ-KPU3W
Upgraded nanoe™ X (Generator Mark 3). Graphite black (RAL9011): CZ-KPU3B

Advanced Econavi functions available (optional). Econavi panel.


White (RAL9003): CZ-KPU3AW
Panel (H x W x D / net weight): 33,5 x 950 x 950 mm / 5 kg.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,2 kW S-22MU2E5C 2,2 2,5 256 x 840 x 840 20 1,432
2,8 kW S-28MU2E5C 2,8 3,2 256 x 840 x 840 20 1,464
3,6 kW S-36MU2E5C 3,6 4,2 256 x 840 x 840 20 1,506
4,5 kW S-45MU2E5C 4,5 5,0 256 x 840 x 840 20 1,591
5,6 kW S-56MU2E5C 5,6 6,3 256 x 840 x 840 20 1,670
1ph 6,0 kW S-60MU2E5C 6,0 7,1 256 x 840 x 840 20 1,697
7,3 kW S-73MU2E5C 7,3 8,0 256 x 840 x 840 20 1,728
9,0 kW S-90MU2E5C 9,0 10,0 256 x 840 x 840 20 1,883
11,2 kW S-112MU2E5C 11,2 14,0 319 x 840 x 840 25 2,023
14,0 kW S-140MU2E5C 14,0 16,0 319 x 840 x 840 25 2,262
16,0 kW S-160MU2E5C 16,0 18,0 319 x 840 x 840 25 2,449

Piping information
Indoor unit R32 kW 2,2 2,8 3,6 4,5 5,6 6,0 7,3 9,0 11,2 14,0 16,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝
Indoor unit R410A kW 2,2 2,8 3,6 4,5 5,6 6,0 7,3 9,0 11,2 14,0 16,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝

Y3 type 4 way 60x60 cassette · R32 / R410A


Upgraded nanoe™ X (Generator Mark 3).
Stylish and full flat panel. Panel.
CZ-KPY4
Panel (H x W x D / net weight): 30 x 625 x 625 mm / 2,8 kg.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
1,5 kW S-15MY3EB 1,5 1,7 243 x 575 x 575 15 1,347
2,2 kW S-22MY3EB 2,2 2,5 243 x 575 x 575 15 1,376
2,8 kW S-28MY3EB 2,8 3,2 243 x 575 x 575 15 1,408
1ph
3,6 kW S-36MY3EB 3,6 4,2 243 x 575 x 575 15 1,436
4,5 kW S-45MY3EB 4,5 5,0 243 x 575 x 575 15 1,532
5,6 kW S-56MY3EB 5,6 6,3 243 x 575 x 575 15 1,667

Piping information
Indoor unit kW 1,5 2,2 2,8 3,6 4,5 5,6
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½

White and graphite black panels


now available for the 4 way 90x90
cassette, offering versatile options for
commercial applications.

Standard panel, Standard panel,


white (RAL9003). graphite black (RAL9011).
CZ-KPU3W CZ-KPU3B

Econavi panel,
white (RAL9003).
CZ-KPU3AW

56
VRF SYSTEMS INDEX VRF SYSTEMS

VRF Systems indoor units


L1 type 2 way cassette · R410A
Simple and easy maintenance.
Auto flat control depending on the operation mode. Panel for S-22 to S-56 models.
CZ-02KPL2
Panel (H x W x D / net weight): 8 x 1 060 x 680 mm / 8 kg. Panel for S-73 model.
CZ-03KPL2

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,2 kW S-22ML1E5 2,2 2,5 350 x 840 x 600 26 1,839
2,8 kW S-28ML1E5 2,8 3,2 350 x 840 x 600 26 1,869
3,6 kW S-36ML1E5 3,6 4,2 350 x 840 x 600 26 1,955
1ph
4,5 kW S-45ML1E5 4,5 5,0 350 x 840 x 600 26 2,190
5,6 kW S-56ML1E5 5,6 6,3 350 x 840 x 600 26 2,235
7,3 kW S-73ML1E5 7,3 8,0 350 x 1 140 x 600 26 2,379

Piping information
Indoor unit kW 2,2 2,8 3,6 4,5 5,6 7,3
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝

D1 type 1 way cassette · R410A


Suitable for standard and high ceilings.
Easy to installation and maintenance. Panel.
CZ-KPD2
Panel (H x W x D / net weight): 20 x 1 230 x 800 mm / 7,5 kg.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,8 kW S-28MD1E5 2,8 3,2 200 x 1 000 x 710 23,5 1,986
3,6 kW S-36MD1E5 3,6 4,2 200 x 1 000 x 710 23,5 2,074
1ph 4,5 kW S-45MD1E5 4,5 5,0 200 x 1 000 x 710 23,5 2,139
5,6 kW S-56MD1E5 5,6 6,3 200 x 1 000 x 710 23,5 2,178
7,3 kW S-73MD1E5 7,3 8,0 200 x 1 000 x 710 24,5 2,373

Piping information
Indoor unit kW 2,8 3,6 4,5 5,6 7,3
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝

Bringing nature’s balance indoors.


All R32 air to air indoor units are equipped with nanoe™ X
(Generator Mark 3) for improved indoor air quality.
The nanoe™ X Generator Mark 3 produces the highest amount of hydroxyl
radicals in nanoe™ history, generating 100 times more than traditional nanoe™.
This increased concentration enhances nanoe™'s cleaning power, delivering
superior performance.

Bacteriophage
inhibition 99%
in 4 hours at the
Y3 type 4 way 60x60 cassette U2 type 4 way 90x90 cassette F3 type variable static
pressure adaptive duct room size 139 m² 1)

M2 type slim variable static K3 type wall-mounted


pressure hide-away

1) [Test organization] SGS Inc. [Test subject] Adhesive virus (bacteriophage) [Test volume] 139 m² [Test result] Inhibited 99% in 4 hours [Device type] nanoe™ X Generator Mark 3, Internal unit: 4 way cassette.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
57
GENERAL INDEX

VRF Systems indoor units


F3 type variable static pressure adaptive duct · R32 / R410A
Upgraded nanoe™ X (Generator Mark 3).
2 installation possibilities (horizontal / vertical) with high ESP Maximum 150 Pa.

Indoor unit Nominal capacity External static pressure Dimension Weight RRP
Cooling Heating HxWxD
kW kW Pa mm kg £
1,5 kW S-15MF3E5D 1,5 1,7 30 (10-150) 250 x 800 x x 730 26 1,551
2,2 kW S-22MF3E5D 2,2 2,5 30 (10-150) 250 x 800 x x 730 26 1,596
2,8 kW S-28MF3E5D 2,8 3,2 30 (10-150) 250 x 800 x x 730 26 1,645
3,6 kW S-36MF3E5D 3,6 4,2 30 (10-150) 250 x 800 x x 730 26 1,701
4,5 kW S-45MF3E5D 4,5 5,0 30 (10-150) 250 x 800 x x 730 26 1,849
5,6 kW S-56MF3E5D 5,6 6,3 30 (10-150) 250 x 800 x x 730 26 1,962
1ph
6,0 kW S-60MF3E5D 6,0 7,1 30 (10-150) 250 x 1 000 x x 730 31 2,036
7,3 kW S-73MF3E5D 7,3 8,0 30 (10-150) 250 x 1 000 x x 730 31 2,089
9,0 kW S-90MF3E5D 9,0 10,0 40 (10-150) 250 x 1 000 x x 730 31 2,147
11,2 kW S-112MF3E5D 11,2 12,5 50 (10-150) 250 x 1 400 x x 730 40 2,296
14,0 kW S-140MF3E5D 14,0 16,0 50 (10-150) 250 x 1 400 x x 730 40 2,488
16,0 kW S-160MF3E5D 16,0 18,0 50 (10-150) 250 x 1 400 x x 730 40 2,626

Piping information
Indoor unit R32 kW 1,5 2,2 2,8 3,6 4,5 5,6 6,0 7,3 9,0 11,2 14,0 16,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝
Indoor unit R410A kW 1,5 2,2 2,8 3,6 4,5 5,6 6,0 7,3 9,0 11,2 14,0 16,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝

NEW M2 type slim variable static pressure hide-away concealed duct · R32 / R410A
New 2025
Upgraded nanoe™ X (Generator Mark 3).
Ultra-slim profile: 200 mm for all capacities.
Ideal for hotel application with very narrow false ceilings.

Indoor unit Nominal capacity External static pressure Dimension Weight RRP
Cooling Heating HxWxD
kW kW Pa mm kg £
1,0 kW S-10MM2EB 1,0 1,3 10 (30) 200 x 700 x 450 17 1,050
1,5 kW S-15MM2EB 1,5 1,7 10 (30) 200 x 700 x 450 17 1,050
2,2 kW S-22MM2EB 2,2 2,5 10 (30) 200 x 700 x 450 17 1,061
1ph 2,8 kW S-28MM2EB 2,8 3,2 15 (30) 200 x 700 x 450 17 1,094
3,6 kW S-36MM2EB 3,6 4,2 15 (40) 200 x 700 x 450 17 1,139
4,5 kW S-45MM2EB 4,5 5,0 15 (40) 200 x 900 x 450 19 1,186
5,6 kW S-56MM2EB 5,6 6,3 15 (40) 200 x 900 x 450 19 1,242

Piping information
Indoor unit kW 1,0 1,5 2,2 2,8 3,6 4,5 5,6
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½

E2 type high static pressure hide-away · R410A


High pressure duct and 100% Fresh air duct function.
Complete flexibility for ductwork design.
* Optional Rap valves required.

Indoor unit 100% Fresh air duct function High pressure duct RRP
Nominal capacity External static Nominal capacity External static Dimension Weight
Cooling Heating pressure Cooling Heating pressure HxWxD
kW kW Pa kW kW Pa mm kg £
22,4 kW S-224ME2E5 22,4 21,2 200 22,4 25,0 140 (60 - 270) 1) 479 x 1 453 x 1 205 102 5,937
1ph
28,0 kW S-280ME2E5 28,0 26,5 200 28,0 31,5 140 (72 - 270) 1) 479 x 1 453 x 1 205 106 6,379

Piping information
Indoor unit kW 22,4 28,0
Piping diameter (liquid - gas) Inch ⅜-¾ ⅜-⅞

Rating Conditions for 100% Fresh air duct function: Cooling Outdoor 33 °C DB / 28 °C WB. Heating outdoor 0 °C DB / -2,9 °C WB.
1) Available to select the setting by initial setup. * No filter included. ** No compatible with 3-Pipe ECO G GF3.

58
VRF SYSTEMS INDEX VRF SYSTEMS

VRF Systems indoor units


T2 type ceiling · R410A
Large and wide air distribution good for big rooms.
All units just 235 mm high.
Horizontal air flow reaches maximum 9,5 m.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
3,6 kW S-36MT2E5A 3,6 4,2 235 x 960 x 690 27 1,545
4,5 kW S-45MT2E5A 4,5 5,0 235 x 960 x 690 27 1,624
5,6 kW S-56MT2E5A 5,6 6,3 235 x 960 x 690 27 1,703
1ph
7,3 kW S-73MT2E5A 7,3 8,0 235 x 1 275 x 690 33 1,776
10,6 kW S-106MT2E5A 10,6 11,4 235 x 1 590 x 690 40 2,164
14,0 kW S-140MT2E5A 14,0 16,0 235 x 1 590 x 690 40 2,473

Piping information
Indoor unit kW 3,6 4,5 5,6 7,3 10,6 14,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝

NEW K3 type wall-mounted · R32 / R410A


Upgraded nanoe™ X (Generator Mark 3). New 2025
Modern, flat design with a stylish matte white finish.
Improved fan serviceability.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
1,5 kW S-15MK3E 1,5 1,7 295 x 890 x 244 12 803
2,2 kW S-22MK3E 2,2 2,5 295 x 890 x 244 12 831
2,8 kW S-28MK3E 2,8 3,2 295 x 890 x 244 12 830
3,6 kW S-36MK3E 3,6 4,2 295 x 890 x 244 12 871
1ph
4,5 kW S-45MK3E 4,5 5,0 295 x 890 x 244 12 999
5,6 kW S-56MK3E 5,6 6,3 295 x 1 060 x 249 14 1,051
7,3 kW S-73MK3E 7,3 8,0 295 x 1 060 x 249 14 1,234
10,6 kW S-106MK3E 10,6 10,6 295 x 1 060 x 249 14 1,266

Piping information
Indoor unit kW 1,5 2,2 2,8 3,6 4,5 5,6 7,3 10,6
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝

New K3 type wall-mounted · R32 /


R410A.
The K3 wall-mounted unit features the upgraded
nanoe™ X (Generator Mark 3) for enhanced air
purification. Its modern, flat design with a stylish
matte white finish complements any interior,
while improved fan serviceability ensures
effortless maintenance.

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
59
GENERAL INDEX

VRF Systems indoor units


G1 type floor console · R410A
nanoe™ X (Generator Mark 1).
Modern design with slim depth.
Self-cleaning function available.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,2 kW S-22MG1E5N 2,2 2,5 600 x 750 x 207 14 1,576
2,8 kW S-28MG1E5N 2,8 3,2 600 x 750 x 207 14 1,656
1ph 3,6 kW S-36MG1E5N 3,6 4,2 600 x 750 x 207 14 1,742
4,5 kW S-45MG1E5N 4,5 5,0 600 x 750 x 207 14 1,839
5,6 kW S-56MG1E5N 5,6 6,3 600 x 750 x 207 14 1,978

Piping information
Indoor unit kW 2,2 2,8 3,6 4,5 5,6
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½

P1 type floor-standing · R410A


Easy to install.
Effective perimeter handling.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,2 kW S-22MP1E5 2,2 2,5 615 x 1 065 x 230 29 1,574
2,8 kW S-28MP1E5 2,8 3,2 615 x 1 065 x 230 29 1,577
3,6 kW S-36MP1E5 3,6 4,2 615 x 1 065 x 230 29 1,615
1ph
4,5 kW S-45MP1E5 4,5 5,0 615 x 1 380 x 230 39 1,836
5,6 kW S-56MP1E5 5,6 6,3 615 x 1 380 x 230 39 1,856
7,1 kW S-71MP1E5 7,1 8,0 615 x 1 380 x 230 39 1,957

Piping information
Indoor unit kW 2,2 2,8 3,6 4,5 5,6 7,1
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝

R1 type concealed floor-standing · R410A


Chassis unit for discreet installation.
Just 229 mm depth.
Easy to install.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
2,2 kW S-22MR1E5 2,2 2,5 616 x 904 x 229 21 1,363
2,8 kW S-28MR1E5 2,8 3,2 616 x 904 x 229 21 1,442
3,6 kW S-36MR1E5 3,6 4,2 616 x 904 x 229 21 1,528
1ph
4,5 kW S-45MR1E5 4,5 5,0 616 x 1 219 x 229 28 1,612
5,6 kW S-56MR1E5 5,6 6,3 616 x 1 219 x 229 28 1,732
7,1 kW S-71MR1E5 7,1 8,0 616 x 1 219 x 229 28 1,765

Piping information
Indoor unit kW 2,2 2,8 3,6 4,5 5,6 7,1
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ¼-½ ¼-½ ⅜-⅝

60
VRF SYSTEMS INDEX VRF SYSTEMS

VRF Systems indoor units


Hydrokit for ECOi, water at 45 °C · R410A
Maximum hot water outlet temperature: 45 °C.
Compatible with 3-Pipe ECOi (VRF) System up to 48 HP.

Indoor unit Nominal capacity Dimension Weight RRP


Cooling Heating HxWxD
kW kW mm kg £
8,0 kW S-80MW1E5 8,0 9,0 892 x 502 x 353 43 3,492
1ph
12,5 kW S-125MW1E5 12,5 14,0 892 x 502 x 353 43 4,189

Piping information
Indoor unit kW 8,0 12,5
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅝

Energy recovery ventilation with DX coil - HRPT Series · R32 / R410A


Dual flow ventilation with EC fan, featuring high efficiency heat recovery (>85% η).
2 types of polystyrene heat exchanger (high efficiency and sensible) with counter-current
flows and integrated bypass as standard.
Modbus connection available.
Indoor unit Heat exchanger option Heat recovery ventilation 1) DX coil 2) RRP
Temperature Enthalpy Air flow External Total / Sensible Dimension Weight
efficiency efficiency static capacity
pressure
Cool Heat Cool Heat High High Cool Heat HxWxD
% % % % m³/h Pa kW kW mm kg £
2,5 kW PAW-HRPT40HX High efficiency 63,4 76,7 52,3 53,2 480 150 2,5 3,0 283 x 975 x 1 400 70 5,409
2,5 kW PAW-HRPT40 Sensible 84,6 84,9 — — 480 150 2,5 3,0 283 x 975 x 1 400 67 4,021
5,0 kW PAW-HRPT80HX High efficiency 60,0 73,5 47,8 49,2 800 150 5,0 6,0 408 x 1 180 x 1 720 120 7,068
5,0 kW PAW-HRPT80 Sensible 84,3 84,7 — — 800 150 5,0 6,0 408 x 1 180 x 1 720 117 5,333
1ph
7,0 kW PAW-HRPT120HX High efficiency 61,4 75,0 49,5 50,7 1 100 150 7,0 8,1 408 x 1 580 x 1 720 135 9,389
7,0 kW PAW-HRPT120 Sensible 84,8 85,2 — — 1 100 150 7,0 8,1 408 x 1 580 x 1 720 132 6,729
10,0 kW PAW-HRPT160HX High efficiency 62,2 76,0 50,0 51,2 1 500 150 10,0 12,5 408 x 1 980 x 1 720 150 11,471
10,0 kW PAW-HRPT160 Sensible 84,7 85,1 — — 1 500 150 10,0 12,5 408 x 1 980 x 1 720 147 7,885
12,5 kW PAW-HRPT200HX High efficiency 59,4 73,2 46,8 48,3 1 750 150 12,5 14,0 408 x 1 980 x 1 720 180 13,437
3ph
12,5 kW PAW-HRPT200 Sensible 83,8 84,2 — — 1 750 150 12,5 14,0 408 x 1 980 x 1 720 177 9,967

Piping information Electrical information


Indoor unit kW 2,5 5,0 7,0 10,0 12,5 Single phase Three phase
Piping diameter (liquid) Inch ¼ ⅜ ⅜ ⅜ ⅜ Indoor unit kW 2,5 5,0 7,0 10,0 12,5 12,5
Piping diameter (gas) Inch ½ ⅝ ⅝ ⅝ ⅝ Maximum input current A 1,5 2,2 4,1 4,4 3,3 3,3

1) Data refers to the following conditions (UNI EN 13141-7): nominal air flow, external air 5 °C with 72% r. / expelled air 25 °C with 28% r. 2) Data refers to the following conditions: nominal air flow, cooling inlet
coil summer 27 °C with 48% / heating inlet coil winter 20 °C with 50% r. * Image is for PAW-HRPT40.

Energy recovery ventilation with DX coil - HRPT Series for VRF.


The HPRT Series is specifically designed for commercial applications or collective residential buildings,
offering highly efficient heat recovery of up to 85,2%.

High-efficiency heat recovery >85% η

PAW-HRPT40HX PAW-HRPT80HX PAW-HRPT120HX PAW-HRPT160/200HX

480 m³/h 800 m³/h 1 100 m³/h 1 500 / 1 750 m³/h

Rating conditions: Cooling indoor 27 °C DB / 19 °C WB. Cooling outdoor 35 °C DB / 24 °C WB. Heating indoor 20 °C DB. Heating outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb).
Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
61
ACCESSORIES AND CONTROL GENERAL INDEX

Distribution joint kits RRP £ Panels RRP £

2-Pipe ME2 for outdoor units (up to CZ-P680PH2BM 190 Standard panel for 4 way 90x90 CZ-KPU3W 242
68,0 kW). cassette, white (RAL9003).
2-Pipe ME2 for outdoor units (from CZ-P1350PH2BM 260
68,0 kW to 168,0 kW). Econavi panel for 4 way 90x90 CZ-KPU3AW 328
cassette, white (RAL9003).
2-Pipe ME2 and Mini ECOi for indoor CZ-P224BK2BM 109
units (up to 22,4 kW*).
2-Pipe ME2 for indoor units (from CZ-P680BK2BM 179 Standard panel for 4 way 90x90 CZ-KPU3B 242
22,4 kW to 68,0 kW*). cassette, graphite black (RAL9011).

2-Pipe ME2 for indoor units (from CZ-P1350BK2BM 243


68,0 kW to 168,0 kW*). Panel for 4 way 60x60 cassette - MY3. CZ-KPY4 266

3-Pipe MF3 for outdoor units (up to CZ-P680PJ2BM 323


68,0 kW).
Panel for 2 way cassette (for S-22 to CZ-02KPL2 427
3-Pipe MF3 for outdoor units (from CZ-P1350PJ2BM 552 S-56 models).
68,0 kW to 135,0 kW).
Panel for 2 way cassette (for S-73 CZ-03KPL2 507
3-Pipe MF3 for indoor units (up to CZ-P224BH2BM 128 model).
22,4 kW).
Panel for 1 way cassette. CZ-KPD2 450
3-Pipe MF3 for indoor units (from CZ-P680BH2BM 318
22,4 kW to 68,0 kW).
3-Pipe MF3 for indoor units (up to CZ-P1350BH2BM 336
68,0 kW).
Sensors RRP £
2-Pipe ME2 header pipe. CZ-P4HP4C2BM 298
3-Pipe MF3 header pipe. CZ-P4HP3C2BM 203 Econavi energy saving sensor. CZ-CENSC1 179
* In case the total capacity of indoor units connected after distribution exceeds the total capacity
of the outdoor units, select the distribution piping size for the total capacity of the outdoor units.

Remote temperature sensor. CZ-CSRC3 129

Heat recovery box RRP £

Cassette fresh air-intake kit. CZ-FDU3+CZ-ATU2 TBC


3-Pipe control Solenoid valve kit (up to KIT-P56HR3 581
5,6 kW).
CZ-P56HR3 + CZ-CAPE2. R32 safety measures RRP £

3-Pipe control Solenoid valve kit (from KIT-P160HR3 681


5,6 to 16,0 kW). Leak detector for 4 way 90x90 CZ-CGLSC2 190
CZ-P160HR3 + CZ-CAPE2. cassettes, 4 way 60x60 cassettes, and
wall-mounted units.
Solenoid valve kit (up to 5,6 kW). CZ-P56HR3 472
R32 refrigerant leak alarm for CZ-CGLALC1 196
Solenoid valve kit (from 5,6 kW to CZ-P160HR3 572 adaptive duct and slim duct units.
16,0 kW).
3-Pipe control PCB. CZ-CAPE2 109 2-pipe safety valve kit. CZ-P1160SVK 1,085

3-Pipe control PCB for wall-mounted. CZ-CAPEK2 119 External 16 V power supply. PAW-16DC-ALC1 TBC
4 ports 3 pipe box (up to 5,6 kW per CZ-P456HR3 2,866
port).

6 ports 3 pipe box (up to 5,6 kW per CZ-P656HR3 3,933 IAQ filter for adaptive ducted unit RRP £
port).
BION air pollutant filter for MF3 15, PAW-APF800F TBC
8 ports 3 pipe box (up to 5,6 kW per CZ-P856HR3 5,359 22, 28, 36, 45 and 56.
port).
BION air pollutant filter for MF3 60 PAW-APF1000F TBC
and 73.
* Tentative
4 ports 3 pipe box (up to 16,0 kW per CZ-P4160HR3 3,195 image. BION air pollutant filter for MF3 90, PAW-APF1400F TBC
port). 106, 112, 140 and 160.

Plenums RRP £
R32 Pump Down solution RRP £

Air inlet plenum for MF3 60, 73 and CZ-DUMPA90MF2 319


Basic Pump Down system (2 way) for PAW-PUD2WB-1 1,306 90.
one R32 Mini ECOi outdoor unit
Air inlet plenum for MF3 106, 112, 140 CZ-DUMPA160MF2 344
and 160.
Leak detection and automatic Pump Down for R410A Air inlet plenum for MM2 22, 28, 36, 45 CZ-DUMPA22MMR2 325
RRP £
refrigerant and 56.

Pump Down system (2 way) for 1 PAW-PUD2W-1R 12,426 Air outlet plenum for MM2 22, 28 and CZ-DUMPA22MMS2 508
outdoor unit. 36.

Pump Down system (2 way) for 2 PAW-PUD2W-2R 13,072 Air outlet plenum for MM2 45 and 56. CZ-DUMPA45MMS3 650
outdoor units. * Plenums installed with an R32 Mini ECOi system may only be used when no Panasonic R32
refrigerant leak detector is required. Please refer to technical data manual for refrigerant
Pump Down system (2 way) for 3 PAW-PUD2W-3R* 14,365 installation requirements.
outdoor units.
Pump Down system (3 way) for 1 PAW-PUD3W-1R 12,426
outdoor unit.
Pump Down system (3 way) for 2 PAW-PUD3W-2R 13,072
outdoor units.
Pump Down system (3 way) for 3 PAW-PUD3W-3R* 14,365
outdoor units.
* Special order requiring the longer lead time than usual. For the detailed information, please
contact an authorised Panasonic dealer.

62
VRF SYSTEMS INDEX ACCESSORIES AND CONTROL

Valves RRP £ Centralised controls RRP £

Rap valve kit. CZ-P160RVK2 690 System controller for 64 indoor units CZ-64ESMC3 897
with weekly timer.
Wall-mounted external valve for CZ-P73SVK3 173
model sizes 15 to 73. Central ON / OFF controller, up to 16 CZ-ANC3 608
* A 3/8 “ to 1/4” reducer is required when combining
groups, 64 indoor units.
the S-73MK3E with ECOi EX R410A outdoor units
(ME2 and MF3).

Wall-mounted external valve for CZ-P106SVK3 289 Intelligent controller (touch screen/ CZ-256ESMC3 TBC
model size 106. web server) to control up to 256
indoors with included load distribution
ratio (LDR).
VRF Smart Connectivity+ RRP £

Remote controller Panasonic Net Con, SER8150R0B1194 608 Centralised controls. BMS system. PC base RRP £
RH, No PIR, R1/R2.
Remote controller Panasonic Net Con, SER8150R5B1194 648 P-AIMS core software: Centralised CZ-CSWKC2 4,855
RH, PIR, R1/R2. software to control up to 1 024 indoor
units.
Wireless ZigBee® Pro module / Green VCM8000V5094P 220
Com card. P-AIMS consumption calculation CZ-CSWAC2 2,776
extension.
Door / window wireless sensor. SED-WDC-G-5045 250 P-AIMS BACnet extension. CZ-CSWBC2 5,548
P-AIMS layout display extension. CZ-CSWGC2 2,084
P-AIMS web application extension. CZ-CSWWC2 2,084
Wall / ceiling (motion) wireless sensor. SED-MTH-G-5045 305
P-AIMS communication adaptor. CZ-CFUNC2 1,413

CO2 sensor. SED-CO2-G-5045 784


Panasonic AC Smart Cloud RRP £

Sensor with room temperature and SED-TRH-G-5045 247


humidity. Panasonic AC Smart Cloud. Cloud CZ-CFUSCC1 508
internet control. Up to 128 groups.
Controls 128 units.
Water leakage sensor. SED-WLS-G-5045 240
Detailed references is in page 65.

Cover frame. Silver. FAS-00 51 BMS interface with S-Link RRP £

A unified interface supporting Modbus, PAW-AC2-BMS-16 2,620


Cover frame. White. FAS-01 51 BACnet, and KNX protocols for up to
16 indoor units.
A unified interface supporting Modbus, PAW-AC2-BMS-64 3,760
Cover frame. Glossy translucent white. FAS-03 91 BACnet, and KNX protocols for up to
64 indoor units.
A unified interface supporting Modbus, PAW-AC2-BMS-128 5,034
Cover frame. Light tan wood. FAS-05 71 BACnet, and KNX protocols for up to
128 indoor units.

Cover frame. Dark brown wood. FAS-06 71


Accessories interfaces RRP £

Commercial Wi-Fi Adaptor. CZ-CAPWFC2 207


Cover frame. Dark black wood. FAS-07 71

Cover frame. Brushed steel finish. FAS-10 91 KNX interface. PAW-RC2-KNX-1i 408

Modbus RTU interface. PAW-RC2-MBS-1 408


Controller and touch controllers for hotels with dry
RRP £
contacts
Modbus RS-485 touch room controller PAW-RE2C4-MOD- 523 Modbus RTU interface to control 4 PAW-RC2-MBS-4 944
with I/O, white. WH indoor/groups.
Touch display control with 2 digital PAW-RE2D4-WH 319
inputs, white. BACnet IP and MSTP. PAW-RC2-BAC-1 674
Modbus RS-485 touch room controller PAW-RE2C4-MOD-BK 523
with I/O, black.
Touch display control with 2 digital PAW-RE2D4-BK 319 KNX interface (Airzone). PAW-AZRC-KNX-1 348
inputs, black.

Hotel sensors for dry contacts RRP £ Modbus RTU interface (Airzone). PAW-AZRC-MBS-1 348

Wall motion sensor 24 V. PAW-WMS-DC 220


BACnet IP and MSTP interface PAW-AZRC-BAC-1 634
Wall motion sensor 240 V AC. PAW-WMS-AC 220 (Airzone).
Ceiling motion sensor 24 V. PAW-CMS-DC 220
RAC interface adapter for integration CZ-CAPRA1 194
Ceiling motion sensor 240 V AC. PAW-CMS-AC 220 into S-Link, plus external input and
alarm/status output (for YKEA-1 units).
Power supply 24 V. PAW-24DC 71

Door or window contact. PAW-DWC 24

63
ACCESSORIES AND CONTROL GENERAL INDEX

Centralised controls. Connection with general equipment RRP £ Accessories PCB RRP £

Adaptor for ON / OFF control of CZ-CAPC3 387 T10 interface PCB with digital and PAW-T10 120
external devices. relay connections.

Demand control for Mini ECOi (LZ2, CZ-CAPDC3 697 PCB for fan speed control of external PAW-ECF TBC
LE2). EC Fan.

Mini series parallel device controlling CZ-CAPBC2 324 R-22 Replacement Kit RRP £
indoor units, maximum 1 group and 8
indoor unit.
Replacement kit for R-22. CZ-SLK2 420
Communication Adaptor. Up to 128 CZ-CFUNC2 1,413
groups. Controls 128 units.

Accessories cables RRP £


Individual controls RRP £
Cable for all the T10 functions. CZ-T10 59
CONEX wired remote controller (non- CZ-RTC6W 172
wireless), white.
Cable to operate external EC fan. PAW-FDC 59
CONEX wired remote controller with CZ-RTC6WBL 203
Bluetooth®, white.
Cable for all option monitoring PAW-OCT 59
CONEX wired remote controller with CZ-RTC6WBLW2 1) 286 signals.
Wi-Fi and Bluetooth®, white.
Cable with force thermo OFF/leakage PAW-EXCT 59
CONEX wired remote controller (non- CZ-RTC6 172 detection.
wireless), black.

CONEX wired remote controller with CZ-RTC6BL 203 Water heat exchanger accessories RRP £
Bluetooth®, black.
Stacking kit for vertically stacking up PAW-3WSK 216
CONEX wired remote controller with CZ-RTC6BLW2 1) 286 to 3 WHE (4 pieces per Kit).
Wi-Fi and Bluetooth®, black.

* BLW2 are models available except for the indoor unit type MU2.
Design wired remote controller with CZ-RTC5B 172
Econavi function.

Infrared remote controller and CZ-RWS3 + 256


receiver for 4 way 60x60 cassette - CZ-RWRY3
MY3 with panel.
Infrared remote controller and CZ-RWS3 + 328
receiver for 4 way 90x90 cassette. CZ-RWRU3W

Infrared remote controller and CZ-RWS3 + 328


receiver for 2 way cassette. CZ-RWRL3

Infrared remote controller and CZ-RWS3 + 328


receiver for 1 way cassette. CZ-RWRD3

Infrared remote controller and CZ-RWS3 + 328


receiver for ceiling. CZ-RWRT3

Infrared remote controller for wall- CZ-RWS3 129


mounted and floor console.

Infrared remote controller and CZ-RWS3 + 328


receiver for all indoor units. CZ-RWRC3

64
VRF SYSTEMS INDEX ACCESSORIES AND CONTROL

Panasonic AC Smart Cloud AC Service Cloud RRP £

Product Reference Items included in a kit Description

CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 508


Cloud base kit KIT-ACSCBASE32
SR-ACSCSTART32 AC Smart Cloud start up to 32 indoor units 225
Up to 32
indoor units AC Smart Cloud access fee SR-ACSC1Y32 AC Smart Cloud access fee for 1 year 109

AC Smart Cloud access fee with


SR-ACSC1Y32CNT AC Smart Cloud access fee for 1 year with data connectivity 270
data connectivity

CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 508


Cloud base kit KIT-ACSCBASE64
SR-ACSCSTART64 AC Smart Cloud start up to 64 indoor units 360
Up to 64
indoor units AC Smart Cloud access fee SR-ACSC1Y64 AC Smart Cloud access fee for 1 year 163

AC Smart Cloud access fee with


SR-ACSC1Y64CNT AC Smart Cloud access fee for 1 year with data connectivity 369
data connectivity

CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 508


Cloud base kit KIT-ACSCBASE128
SR-ACSCSTART128 AC Smart Cloud start up to 128 indoor units 539
Up to 128
indoor units AC Smart Cloud access fee SR-ACSC1Y128 AC Smart Cloud access fee for 1 year 234

AC Smart Cloud access fee with


SR-ACSC1Y128CNT AC Smart Cloud access fee for 1 year with data connectivity 530
data connectivity

2x CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 1,016


Cloud base kit KIT-ACSCBASE192
SR-ACSCSTART192 AC Smart Cloud start up to 192 indoor units 647
Up to 192
indoor units AC Smart Cloud access fee SR-ACSC1Y192 AC Smart Cloud access fee for 1 year 304

AC Smart Cloud access fee with


SR-ACSC1Y192CNT AC Smart Cloud access fee for 1 year with data connectivity 663
data connectivity

2x CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 1,016


Cloud base kit KIT-ACSCBASE256
SR-ACSCSTART256 AC Smart Cloud start up to 256 indoor units 809
Up to 256
indoor units AC Smart Cloud access fee SR-ACSC1Y256 AC Smart Cloud access fee for 1 year 374

AC Smart Cloud access fee with


SR-ACSC1Y256CNT AC Smart Cloud access fee for 1 year with data connectivity 888
data connectivity

3x CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 1,524


Cloud base kit KIT-ACSCBASE320
SR-ACSCSTART320 AC Smart Cloud start up to 320 indoor units 929
Up to 320
indoor units AC Smart Cloud access fee SR-ACSC1Y320 AC Smart Cloud access fee for 1 year 430

AC Smart Cloud access fee with


SR-ACSC1Y320CNT AC Smart Cloud access fee for 1 year with data connectivity 888
data connectivity

4x CZ-CFUSCC1 Cloud adapter for ECOi. PACi and ECO G 1) 2,032


Cloud base kit KIT-ACSCBASE512
SR-ACSCSTART512 AC Smart Cloud start up to 512 indoor units 1,293
Up to 512
indoor units AC Smart Cloud access fee SR-ACSC1Y512 AC Smart Cloud access fee for 1 year 598

AC Smart Cloud access fee with


SR-ACSC1Y512CNT AC Smart Cloud access fee for 1 year with data connectivity 1,128
data connectivity

Options RRP £

Panasonic AC Service Cloud SR-ACSC1Y32M AC Service Cloud access for 1 year up to 32 indoor units 109
Service
function
System Health Check 2) SR-ACSC1Y32SHC System Health Check access for 1 year up to 32 indoor units 60

Floor map 3)
SR-ACSC1FLRUP Upload 1 floor map or maximum 32 units 225

Floor map 3) SR-ACSC1FLRCP Create 1 floor map or maximum 32 units 360

Indoor assign 3) SR-ACSC32ASSIGN Assign indoors up to 32 units 225

PAW-ACSCRTR4G AC Smart Cloud 4G connection kit including 4G router and SIM 206
4G connectivity kit 4) KIT-ACSC4GCNT
PAW-ACSCSIM card 33

4G Router PAW-ACSCRTR4G 4G Router for Panasonic AC Smart Cloud 206

SIM card PAW-ACSCSIM SIM card without data amount 33

* One cloud adapter is required per 128 indoor units. 1) The adapter has to be sold always together with start up. 2) AC Service Cloud is required to use this function. 3) Floor map and indoor assignments can be
done by customer without additional charge. 4) Data amount of SIM card is not included.

65
GENERAL INDEX

Panasonic ventilation
solutions
Panasonic ventilation solutions for maximum
savings and easy integration.

AHU connection kit MAH4M for ECOi 2-Pipe.


· Space-saving compact casing
· Direct Modbus communication without the need for an
additional interface
· Accurate control with a pressure transducer

Advanced energy recovery ventilation - ZY Series.


Extended line-up covering 2 000 m³/h model meet a variety
of commercial uses.
· F7 grade filter bult-in all models
· Independent motors equipped for air supply / exhaust
· Easily adjust air volume balance - 4 speeds setting for air
supply / exhaust
· Intuitive control design
· BMS connection available (RS485 built-in controller)
· NEW IAQ Controller for enhanced air quality, reduced
energy consumption, and auxiliary heater control

Air curtain with DX coil.


· Line-up available for PACi and VRF system
· Compatible with R32 and R410A refrigerants
· Simple structure for easy installation and maintenance

Ceiling mounted air-e nanoe™ X Generator.


First standalone nanoe™ X Generator available.
Compact and modern design match well into any ceiling
materials.
· Quiet operation - at 27 dB(A)
· Low power consumption
· Easy Installation
· nanoe™ X is a filter free solution that does not require
maintenance

66
VENTILATION

Page 2,5 kW 3,6 kW 5,0 kW 6,0 kW 7,5 kW 10,0 kW 12,5 kW 14,0 kW 20,0 kW 25,0 kW

AHU connection kit


PAH3M-1 for PACi NX
and PACi
P. 68

PAW- 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1 280PAH3M-1

Page 6 HP 12 HP 16 HP 18 HP

AHU connection kit


MAH4M for ECOi
2-Pipe
P. 69

PAW-P+100MAH4M PAW-P+100MAH4M PAW-P+100MAH4M PAW-P+100MAH4M

Page 5 HP 10 HP 20 HP 30 HP 40 HP 50 HP 60 HP 70 HP 80 HP

AHU connection kit


MAH3M for ECOi and
ECO G
P. 68
560MAH3M 560MAH3M
560MAH3M 560MAH3M
280MAH3M 560MAH3M 560MAH3M 560MAH3M
PAW- 160MAH3M 280MAH3M 560MAH3M 560MAH3M 560MAH3M
560MAH3M 560MAH3M 560MAH3M 560MAH3M
280MAH3M 560MAH3M
280MAH3M 560MAH3M

Page 150 m³/h 250 m³/h 350 m³/h 500 m³/h 650 m³/h 800 m³/h 1 000 m³/h 1 500 m³/h 2 000 m³/h

Advanced energy
recovery ventilation -
ZY Series
P. 70

FV-15ZY1G FV-25ZY1G FV-35ZY1G FV-50ZY1G FV-65ZY1G FV-80ZY1G FV-1KZY1G FV-1HZY1G FV-2KZY1G

Page 480 m³/h 800 m³/h 1 100 m³/h 1 500 m³/h 1 750 m³/h

Energy recovery
ventilation with DX
coil - HRPT Series
P. 61
PAW-HRPT40HX PAW-HRPT80HX PAW-HRPT120HX PAW-HRPT160HX PAW-HRPT200HX
PAW-HRPT40 PAW-HRPT80 PAW-HRPT120 PAW-HRPT160 PAW-HRPT200

PACi 7,1 kW 10,0 kW 14,0 kW 20,0 kW


Outdoor unit
Page
capacity
VRF 4 HP 4 HP 5 HP 8 HP

Air curtain with DX


coil

PAW-10PAIRC-LS-1 PAW-15PAIRC-LS-1 PAW-20PAIRC-LS-1 PAW-25PAIRC-LS-1


P. 71 PAW-10PAIRC-HS-1 PAW-15PAIRC-HS-1 PAW-20PAIRC-HS-1 PAW-25PAIRC-HS-1

PAW-10EAIRC-LS PAW-15EAIRC-LS PAW-20EAIRC-LS PAW-25EAIRC-LS


PAW-10EAIRC-HS PAW-15EAIRC-HS PAW-20EAIRC-HS PAW-25EAIRC-HS

67
GENERAL INDEX

Panasonic ventilation solutions


AHU connection kit PAH3M-1 for PACi NX and PACi
CONEX Bluetooth® version (CZ-RTC6BL) is built-in.
Easy connection and set-up is possible via Bluetooth®.
0-10 V demand control.

Reference With PACi NX Elite With PACi NX Standard


Nominal capacity Nominal capacity Dimension Weight RRP
Cooling Heating Cooling Heating HxWxD
kW kW kW kW mm kg £
2,5 kW PAW-280PAH3M-1 — — 2,5 3,2 500 x 400 x 150 11,5
3,6 kW PAW-280PAH3M-1 3,6 3,6 3,6 3,6 500 x 400 x 150 11,5
5,0 kW PAW-280PAH3M-1 5,0 5,0 5,0 5,0 500 x 400 x 150 11,5
6,0 kW PAW-280PAH3M-1 6,0 6,0 6,0 6,0 500 x 400 x 150 11,5
7,5 kW PAW-280PAH3M-1 7,1 7,5 7,1 7,1 500 x 400 x 150 11,5
1,844
10,0 kW PAW-280PAH3M-1 10,0 10,8 10,0 10,0 500 x 400 x 150 11,5
12,5 kW PAW-280PAH3M-1 12,5 13,5 12,5 12,5 500 x 400 x 150 11,5
14,0 kW PAW-280PAH3M-1 14,0 15,5 14,0 14,0 500 x 400 x 150 11,5
20,0 kW PAW-280PAH3M-1 19,0 22,4 — — 500 x 400 x 150 11,5
25,0 kW PAW-280PAH3M-1 22,0 24,0 — — 500 x 400 x 150 11,5

Piping information
Model kW 2,5 3,6 5,0 6,0 7,5 10,0 12,5 14,0 20,0 25,0
Piping diameter (liquid - gas) Inch ¼-½ ¼-½ ¼-½ ⅜-⅝ ⅜-⅝ ⅜-⅝ ⅜-⅝ ½-⅞ ½-⅞ ½-⅞
Pipe length range (Standard) m 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50 5 ~ 50 — —
Pipe length range (Elite) m — 3 ~ 40 3 ~ 40 3 ~ 40 5 ~ 60 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 100 5 ~ 100
Elevation difference (in / out) m 15 30 30 30 30 30 30 30 30 30

AHU connection kit MAH3M for ECOi and ECO G


Available with ECOi and ECO G Series.
CONEX Bluetooth® version (CZ-RTC6BL) is built-in.
0-10 V demand control.

Reference Nominal capacity Air flow Dimension Weight RRP


Cooling Heating Min / Max HxWxD
kW kW m³/h mm kg £
5 HP PAW-160MAH3M 14,0 16,0 1 140 / 2 600 500 x 400 x 150 11,5 1,763
10 HP PAW-280MAH3M 28,0 31,5 3 500 / 5 000 500 x 400 x 150 11,5 1,924
20 HP PAW-560MAH3M 56,0 63,0 7 000 / 10 000 500 x 400 x 150 11,5 2,145
30 HP PAW-280MAH3M + PAW-560MAH3M 84,0 95,0 10 500 / 15 000 500 x 400 x 150* 11,5* 4,069
40 HP PAW-560MAH3M + PAW-560MAH3M 112,0 127,0 14 000 / 20 000 500 x 400 x 150* 11,5* 4,290
50 HP PAW-560MAH3M + PAW-560MAH3M + PAW-280MAH3M 140,0 155,0 17 500 / 25 000 500 x 400 x 150* 11,5* 6,214
60 HP PAW-560MAH3M + PAW-560MAH3M + PAW-560MAH3M 168,0 189,0 21 000 / 30 000 500 x 400 x 150* 11,5* 6,435
70 HP PAW-560MAH3M + PAW-560MAH3M + PAW-560MAH3M + PAW-280MAH3M 196,0 219,0 24 000 / 35 000 500 x 400 x 150* 11,5* 8,359
80 HP PAW-560MAH3M + PAW-560MAH3M + PAW-560MAH3M + PAW-560MAH3M 224,0 252,0 28 000 / 40 000 500 x 400 x 150* 11,5* 8,580

Piping information
Model HP 5 10 20 30 40 50 60 70 80
Piping diameter (liquid - gas) Inch ⅜-⅝ ⅜-⅞ ⅝-1⅛ ¾-1⅜ ¾-1⅝ ¾-1 ⅝ ¾-1⅝ ⅞-1⅝ ⅞-2⅛
Pipe length range m 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100
Elevation difference (in / out) m 10 10 10 10 10 10 10 10 10

*The value applies to one unit of the AHU connection kit.

AHU connection kit / system combination


Capacity ECOi Series AHU kit Capacity ECO G Series AHU kit
5 HP 16 kW Mini ECOi / ECOi EX ME2 Series 160MAH3M — — — 5 HP 16 kW All ECO G 160MAH3M
U-8LZ2E8/U-10LZ2E8/
10 HP 28 kW U-8LE1E8/U-10LE1E8/ — — 280MAH3M — — — 10 HP 28 kW All ECO G 280MAH3M
U-10ME2E8
20 HP 56 kW U-20ME2E8 — — 560MAH3M — — — 20 HP 56 kW U-20GE3E5 560MAH3M
30 HP 84 kW U-16ME2E8 U-14ME2E8 — 560MAH3M 280MAH3M — —
40 HP 112 kW U-20ME2E8 U-20ME2E8 — 560MAH3M 560MAH3M — —
50 HP 140 kW U-18ME2E8 U-16ME2E8 U-16ME2E8 560MAH3M 560MAH3M 280MAH3M —
60 HP 168 kW U-20ME2E8 U-20ME2E8 U-20ME2E8 560MAH3M 560MAH3M 560MAH3M —
70 HP 196 kW U-20ME2E8 U-20ME2E8 U-20ME2E8 560MAH3M 560MAH3M 560MAH3M 280MAH3M
80 HP 224 kW U-20ME2E8 U-20ME2E8 U-20ME2E8 560MAH3M 560MAH3M 560MAH3M 560MAH3M

68
VENTILATION INDEX VENTILATION

Panasonic ventilation solutions


AHU connection kit MAH4M for ECOi 2-Pipe
Space-saving compact casing.
Direct Modbus communication without the need for an additional interface.
Accurate control with a pressure transducer.

Reference Nominal capacity Air flow Dimension Weight RRP


Cooling Heating Min / Max HxWxD
kW kW m³/h mm kg £
6 HP PAW-P+100MAH4M 16,0 17,0 1 800 / 4 400 300 x 400 x 150 11 2,121
12 HP PAW-P+100MAH4M 33,5 37,5 2 000 / 10 000 300 x 400 x 150 11 2,121
16 HP PAW-P+100MAH4M 45,0 50,0 3 500 / 12 000 300 x 400 x 150 11 2,121
18 HP PAW-P+100MAH4M 56,0 63,0 5 000 / 20 000 300 x 400 x 150 11 2,121

Piping information
Model HP 5 6 8 10 12 14 16 18
Piping diameter (liquid - gas) ≤ 90 m Inch ⅜-⅝ ⅜-⅝ ⅜-¾ ⅜-⅞ ½-1⅛ ½-1⅛ ½-1⅛ ⅝-1⅛
Piping diameter (liquid - gas) > 90 m 1) — — ½-⅞ ½-1⅛ ⅝-1⅛ ⅝-1⅛ ⅝ - 1⅜ ¾-1 ⅜
Pipe length range m 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100 10 ~ 100
Elevation difference (in / out) m 10 10 10 10 10 10 10 10

1) For R410A models only.

AHU connection kit / system combination


Cooling Mini VRF 2-Pipe VRF AHU connection kit EEV pack
capacity Mini ECOi LZ2 Series (R32) Mini ECOi LE2 Series (R410A) ECOi EX ME2 Series
U-4LZ2E5(8) / U-5LZ2E5(8) / U-4LE2E5(8) / U-5LE2E5(8) /
4 ~ 6 HP — PAW-P+100MAH4M PAW-P+116EEVPACK
U-6LZ2E5(8) U-6LE2E5(8)
U-8ME2E8 / U-10ME2E8 /
8 ~ 12 HP U-8LZ2E8 / U-10LZ2E8 U-8LE1E8 / U-10LE1E8 PAW-P+100MAH4M PAW-P+133EEVPACK
U-12ME2E8
U-14ME2E8 / U-16ME2E8 /
14 ~ 18 HP — — PAW-P+100MAH4M PAW-P+145EEVPACK
U-18ME2E8

Accessories RRP £ Accessories RRP £


AHU connection kit sensor pack 1 (2 pcs of EEV pack 3 (1 pc of expansion valve ≤ 45 kW
PAW-P+145EEVPACK 157
PAW-P+102SENSPACK SENSOR PT1000 HT IP67 -50/250 CABLE 6 m 247 (R410A / R32) and 1 pc of UNIPOLAR stator)
PCK)
Remote control pack (1 pc of PGNE
EEV pack 1 (1 pc of expansion valve ≤ 16 kW PAW-P+100PGNEPACK 132 x 64 mm, mounting panel and 1 pc of cable 546
PAW-P+116EEVPACK 133 L= 1,5 m, telephone connectors)
(R410A / R32) and 1 pc of UNIPOLAR stator)
EEV pack 2 (1 pc of expansion valve ≤ 33 kW
PAW-P+133EEVPACK 157
(R410A / R32) and 1 pc of UNIPOLAR stator)

Optional parts for AHU connection kit MAH4M RRP £ Optional parts for AHU connection kit RRP £

AHU connection kit sensor pack 1 PAW-P+102SENSPACK 247 Design wired remote controller with CZ-RTC5B 172
(2 pcs of SENSOR PT1000 HT IP67 Econavi function.
-50/250 CABLE 6 m PCK)
EEV pack 1 (1 pc of expansion valve PAW-P+116EEVPACK 133
≤ 16 kW (R410A / R32) and 1 pc of
UNIPOLAR stator)
EEV pack 2 (1 pc of expansion valve PAW-P+133EEVPACK 157
≤ 33 kW (R410A / R32) and 1 pc of
UNIPOLAR stator)
EEV pack 3 (1 pc of expansion valve PAW-P+145EEVPACK 157
≤ 45 kW (R410A / R32) and 1 pc of
UNIPOLAR stator)
Remote control pack (1 pc of PGNE PAW-P+100PGNEPACK 546
132 x 64 mm, mounting panel and 1 pc
of cable L= 1,5 m, telephone
connectors)

69
GENERAL INDEX

Panasonic ventilation solutions


Advanced energy recovery ventilation - ZY Series 1HZY1G / 2KZY1G 1)

Extended 9 model line-up including 2 000 m³/h model.


F7 grade filter built-in as a standard. 15ZY1G ~ 1KZY1G 1)

Design remote controller with RS485 for BMS integration.

Reference Air flow External static pressure Heating exchange Fuse Dimension Weight RRP
efficiency Rating
Hi Hi HxWxD
m³/h Pa % A mm kg £
150 m³/h FV-15ZY1G 150 100 83 5 289 x 610 x 860 23 1,537
250 m³/h FV-25ZY1G 250 120 82 5 289 x 735 x 860 27 1,681
350 m³/h FV-35ZY1G 350 140 83 5 331 x 874 x 968 37 2,008
500 m³/h FV-50ZY1G 500 130 81 5 331 x 1 016 x 968 40 2,086
1ph 650 m³/h FV-65ZY1G 650 150 82 5 404 x 954 x 1 008 48 2,400
800 m³/h FV-80ZY1G 800 150 83 5 404 x 1 004 x 1 224 60 2,767
1 000 m³/h FV-1KZY1G 1 000 150 82 10 404 x 1 231 x 1 224 64 3,228
1 500 m³/h FV-1HZY1G 1 500 130 83 10 808 x 1 004 x 1 224 119 5,485
2 000 m³/h FV-2KZY1G 2 000 130 82 10 808 x 1 231 x 1 224 142 6,833

1) Different dimensions depending on models. * A remote controller is included.

Replacement high efficiency filter for FV-FP65ZY1G 89


Advanced energy recovery ventilation accessories RRP £ FV-65ZY1G.

Replacement high efficiency filter for FV-FP15ZY1G 59 Replacement high efficiency filter for FV-FP80ZY1G 94
FV-15ZY1G. FV-80ZY1G and FV-1HZY1G 1).

Replacement high efficiency filter for FV-FP25ZY1G 63 Replacement high efficiency filter for FV-FP1KZY1G 104
FV-25ZY1G. FV-1KZY1G and FV-2KZY1G 1).

Replacement high efficiency filter for FV-FP35ZY1G 74 IAQ Controller for advanced energy PAW-ERV-IAQCT TBC
FV-35ZY1G. recovery ventilation - ZY Series 2).

Replacement high efficiency filter for FV-FP50ZY1G 83


FV-50ZY1G. 1) 2 sets of filters required for those models. 2) Available in Spring 2025.

New ERV IAQ Controller.


The IAQ Controller optimises indoor air quality while reducing
energy consumption. It also provides seamless control
of auxiliary heaters, ensuring a comfortable and efficient
environment. It is compatible with the ERV - ZY Series.
* Available in Spring 2025.

PAW-ERV-IAQCT

Electric air curtain


Comprehensive product line up (width: 0,9 m 1,2 m and 1,5 m).
Simple structure for easy installation and maintenance.

Reference Width Air flow Consumption Dimension Weight RRP


Hi / Lo Hi / Lo HxWxD
mm m³/h W mm kg £
FY-3009U1 900 1 100 / 920 76 / 70 231,5 x 900 x 212 12,0 809
1ph FY-3012U1 1 200 1 400 / 1 270 94 / 85 231,5 x 1 200 x 212 14,5 906
FY-3015U1 1 500 2 000 / 1 800 131 / 110 231,5 x 1 500 x 212 18,0 1,061

70
VENTILATION INDEX VENTILATION

Panasonic ventilation solutions


Air curtain with DX coil, connected to PACi systems
Compatible with R32 and R410A refrigerant.
Simple structure for easy installation and maintenance.
Easy redirection of air flow with manual deflector.

Reference Maximum capacity Air flow Dimension 3) Weight RRP


Cooling 1) Heating 2) Hi HxWxD
kW kW m³/h mm kg £
PAW-10PAIRC-LS-1 6,1 7,9 1 800 260 (+140) x 1 000 x 460 50 8,777

Air outlet height PAW-15PAIRC-LS-1 9,7 12,0 2 700 260 (+140) x 1 500 x 460 65 10,236
2,7 m PAW-20PAIRC-LS-1 13,0 15,0 3 600 260 (+140) x 2 000 x 460 80 11,540
PAW-25PAIRC-LS-1 17,0 19,0 4 500 260 (+140) x 2 500 x 460 95 12,929
1ph
PAW-10PAIRC-HS-1 9,1 11,8 2 700 260 (+140) x 1 000 x 460 55 9,147

Air outlet height PAW-15PAIRC-HS-1 13,0 15,8 3 600 260 (+140) x 1 500 x 460 65 10,528
3,0 m PAW-20PAIRC-HS-1 19,5 23,6 5 400 260 (+140) x 2 000 x 460 85 12,051
PAW-25PAIRC-HS-1 23,7 27,6 6 300 260 (+140) x 2 500 x 460 110 13,197

LS / PACi outdoor combination* PACi Elite PACi Standard HS / PACi outdoor combination* PACi Elite PACi Standard
Operation until 40 °C 35 °C 30 °C 40 °C 35 °C 30 °C Operation until 40 °C 35 °C 30 °C 40 °C 35 °C 30 °C
PAW-10PAIRC-LS-1 U-100 U-100 U-50 U-100 U-100 U-60 PAW-10PAIRC-HS-1 U-200 U-100 U-100 — U-100 U-100
PAW-15PAIRC-LS-1 U-200 U-100 U-100 — U-100 U-100 PAW-15PAIRC-HS-1 U-200 U-200 U-100 — — U-100
PAW-20PAIRC-LS-1 U-200 U-140 U-100 — — U-100 PAW-20PAIRC-HS-1 — U-250 U-200 — — —
PAW-25PAIRC-LS-1 U-250 U-200 U-125 — — U-125 PAW-25PAIRC-HS-1 — U-250 U-200 — — —

1) Cooling capacity DX coil, air temperature in / out +27 / +18 °C, R32 and R410. 2) Heating capacity condenser, air temperature in / out +20 / +33 °C, R32 and R410. In the case of lower outdoor temperatures, an
outdoor model with higher capacity may be necessary. 3) 140 mm is the height of an electrical box if it is installed on the top.

Air curtain with DX coil, connected to VRF systems


Compatible with R32 and R410A refrigerant.
Simple structure for easy installation and maintenance.
Easy redirection of air flow with manual deflector.

Reference Maximum capacity Air flow Dimension 3) Weight RRP


Cooling 1)
Heating 2)
Hi HxWxD
kW kW m³/h mm kg £
PAW-10EAIRC-LS 6,1 7,9 1 800 260 (+140) x 1 000 x 460 50 9,485

Air outlet height PAW-15EAIRC-LS 9,7 12,0 2 700 260 (+140) x 1 500 x 460 65 11,203
2,7 m PAW-20EAIRC-LS 13,0 15,0 3 600 260 (+140) x 2 000 x 460 80 12,604
PAW-25EAIRC-LS 17,0 19,0 4 500 260 (+140) x 2 500 x 460 95 14,103
1ph
PAW-10EAIRC-HS 9,1 11,8 2 700 260 (+140) x 1 000 x 460 55 9,883

Air outlet height PAW-15EAIRC-HS 13,0 15,8 3 600 260 (+140) x 1 500 x 460 65 11,513
3,0 m PAW-20EAIRC-HS 19,5 23,6 5 400 260 (+140) x 2 000 x 460 85 13,149
PAW-25EAIRC-HS 23,7 27,6 6 300 260 (+140) x 2 500 x 460 110 14,387

LS / VRF outdoor combination HS / VRF outdoor combination


Operation until 40 °C 35 °C 30 °C Operation until 40 °C 35 °C 30 °C
PAW-1EAIRC-LS U-4 U-4 U-4 PAW-10EAIRC-HS U-6 U-5 U-4
PAW-15EAIRC-LS U-6 U-5 U-4 PAW-15EAIRC-HS U-8 U-6 U-4
PAW-20EAIRC-LS U-8 U-6 U-4 PAW-20EAIRC-HS U-8 U-8 U-8
PAW-25EAIRC-LS U-8 U-8 U-5 PAW-25EAIRC-HS U-12 U-10 U-8

1) Cooling capacity DX coil, air temperature in / out +27 / +18 °C, R32 and R410. 2) Heating capacity condenser, air temperature in / out +20 / +33 °C, R32 and R410. In the case of lower outdoor temperatures, an
outdoor model with higher capacity may be necessary. 3) 140 mm is the height of an electrical box if it is installed on the top. * Also compatible with ECO G Series (GE3 and GF3) and Hybrid Serie.

Ceiling mounted air-e nanoe™ X Generator


nanoe™ X (Generator Mark 1).
Silent operation.
Low power consumption.

Reference Air flow Consumption Sound pressure Panel dimension Hole size dimension Net weight RRP
m³/h W dB(A) mm mm kg £
1ph FV-15CSD1G 16 4 25,5 Ø200 Ø145 1,1 363

71
GENERAL INDEX

Close Control and


Vertical DX units
Close Control units provide a strict control of
environmental conditions such as temperature,
humidity in data centers, laboratories, and other
applications where sensitive equipment or processes
require stable and controlled conditions.
Vertical DX units can be used in industries, data
centers and tertiary application thanks to their high
reliability, high efficiency and low noise level.

72
CLOSE CONTROL / VERTICALCHILLERS
DX UNITS

Different versions for data centers applications: Flexibility, reliability and advanced remote control.
CCUs small footprint and the possibility of modulating CCUs are flexible solutions that can be customised to fit
operation for all components allow the development of the specific requirements of data centers applications.
solutions tailored to the real needs of the infrastructure. These environments also require high levels of reliability.
P Series: Perimetral and compact solution. Real-time remote monitoring and control of all unit
G Series: Perimetral and high efficiency solution for operating cycles thanks to a simple and intuitive large
large data centers. colour display and touch keys.
R Series: In-row solution.
W Series: Technical corridor solution.
Vertical DX units.
This range of monobloc cabinets has the particularity of
Precise control of temperature and humidity. extremely simplified implementation and maintenance.
CCUs are designed to provide precise and stable control They have a small footprint, high reliability and efficiency
over temperature and humidity levels. This is crucial in which combined with low noise level make them
environments where even small variations can have a particularly well suited for cooling, heating and air
significant impact on equipment performance or the filtration in industries, data center and tertiary application.
quality of processes.

73
GENERAL INDEX

Quick selection guide - Close Control - chilled water


Page Size Cooling capacity (kW) Air flow Sound pressure Dimension
(m³/h) (dB(A)) H x W x D (mm)

P Series - Perimetral 10 9,9 2 200 51 1 990 x 750 x 600

20 17,2 3 200 59 1 990 x 750 x 600

30 30,0 7 000 56 1 990 x 860 x 880

50 41,0 8 000 60 1 990 x 860 x 880

60 52,8 12 000 67 1 990 x 1 410 x 880

P. 76 70 63,1 12 000 68 1 990 x 1 410 x 880

80 65,4 16 000 61 1 990 x 1 750 x 880

110 80,0 18 000 62 1 990 x 1 750 x 880

160 110,0 24 000 62 1 990 x 2 640 x 880

220 160,0 36 000 65 1 990 x 3 495 x 880

G Series - Great 70 55,5 11 000 58 1 990 x 1 320 x 921

150 112,6 23 000 60 1 990 x 1 840 x 921

150 XH 129,7 26 000 62 2 350 x 1 840 x 1 050

P. 76 230 176,6 36 000 63 1 990 x 2 740 x 921

230 XH 220,7 39 000 65 2 350 x 2 740 x 1 050

300 202,8 45 200 62 1 990 x 4 020 x 921

R Series - In-Row
20 24,5 5 600 53 1 970 x 300 x 1 200

P. 77
40 37,3 9 000 62 2 000 x 600 x 1 220

W Series - Cold Wall 2X1 112,0 25000 71 1 800 x 1 900 x 1 400

3X1 189,9 37500 72 1 800 x 2 850 x 1 400

4X1 258,9 50000 72 1 800 x 3 800 x 1 400

P. 77 2X2 224,0 50000 72 3 600 x 1 900 x 1 400

3X2 379,9 75000 74 3 600 x 2 850 x 1 400

4X2 500,5 96000 74 3 600 x 3 800 x 1 400

74
CLOSE CONTROL / VERTICAL DX INDEX CLOSE CONTROL / VERTICALCHILLERS
DX UNITS

Quick selection guide - Close Control - direct expansion


Page Size Cooling capacity (kW) Air flow Sound pressure Dimension
(m³/h) (dB(A)) H x W x D (mm)

P Series - Perimetral 71 8,2 2 200 51 1 990 x 750 x 600

141 14,7 3 200 59 1 990 x 750 x 600

211 21,0 7 000 56 1 990 x 860 x 880

251 27,4 7 000 57 1 990 x 860 x 880

301 32,3 12 000 67 1 990 x 1 410 x 880

321 35,2 12 000 67 1 990 x 1 410 x 880

322 33,8 12 000 67 1 990 x 1 410 x 880

P. 76 361 38,1 14 000 58 1 990 x 1 750 x 880

461 48,1 14 000 58 1 990 x 1 750 x 880

422 43,7 14 000 58 1 990 x 1 750 x 880

512 57,8 14 000 59 1 990 x 1 750 x 880

662 67,3 18 000 61 1 990 x 2 300 x 880

852 84,4 18 000 61 1 990 x 2 300 x 880

932 94,9 21 000 61 1 990 x 2 640 x 880

G Series - Great
932 102,6 18 000 56 1 990 x 2 390 x 921

P. 76
1342 153,9 31 500 61 1 990 x 3 120 x 921

R Series - In-Row 121 11,4 3 200 51 1 970 x 300 x 1 200

201 22,0 3 600 53 1 970 x 300 x 1 200

P. 77 231 22,9 6 000 54 2 000 x 600 x 1 220

361 36,6 6 000 56 2 000 x 600 x 1 220

Quick selection guide - Vertical DX units


Page Size Cooling capacity (kW) Air flow Sound pressure Dimension
(m³/h) (dB(A)) L x W x H (mm)

T-XAR · R407C - air cooled models 1 200 12,3 2,000 51 890 x 1 540 x 430

1 900 16,2 3,200 56 1 000 x 1 735 x 500

2 450 19,8 4,500 59 1 300 x 1 840 x 600

P. 78 3 250 29,0 5,800 65 1 530 x 1 830 x 600

4 650 38,9 9,000 61 1 715 x 1 970 x 790

6 450 55,0 12,000 69 1 980 x 1 970 x 790

T-CX and T-XAO · R407C - water cooled 25 8,0 1,500 52 800 x 1 280 x 407
models
1 200 15,0 2,000 51 890 x 1 540 x 430

1 900 18,0 3,200 55 1 000 x 1 735 x 500

2 450 23,0 4,500 58 1 300 x 1 840 x 600


P. 79
3 250 32,4 5,800 64 1 530 x 1 830 x 600

4 650 45,7 9,000 60 1 715 x 1 970 x 790

75
GENERAL INDEX

Close Control units


P Series - Perimetral
Perimetral and compact solution.
Versions with upflow and downflow air discharge configurations.
Very high EER (energy efficiency ratio) and low operating costs.
Direct expansion or Chilled water system.
Outdoor Cooling Sensible EER 2) Air flow Sound Dimension Weight Air-cooled Water- Two RRP
unit capacity 1) cooling pressure 3) free cooling cooled free sources
HxWxD
capacity 1) cooling

kW kW m³/h dB(A) mm kg £
UPA/OPA - direct expansion air conditioners with air-cooled or water-cooled condensers
71 8,2 7,9 3,83 2 200 51 1 990 x 750 x 600 170 ● ○ ○
141 14,7 12,9 3,40 3 200 59 1 990 x 750 x 600 225 ● ○ ○
211 21,0 21,0 3,30 7 000 56 1 990 x 860 x 880 280 ● ○ ●
251 27,4 25,7 3,14 7 000 57 1 990 x 860 x 880 305 ● ○ ○
301 32,3 32,3 3,21 12 000 67 1 990 x 1 410 x 880 360 ● ○ ○
321 35,2 35,2 3,13 12 000 67 1 990 x 1 410 x 880 385 ● ● ●
322 33,8 33,8 3,34 12 000 67 1 990 x 1 410 x 880 430 ● ○ ○
POA
361 38,1 38,1 3,57 14 000 58 1 990 x 1 750 x 880 460 ● ○ ○
461 48,1 46,8 3,63 14 000 58 1 990 x 1 750 x 880 470 ● ● ●
422 43,7 43,7 3,47 14 000 58 1 990 x 1 750 x 880 535 ● ○ ○
512 57,8 53,6 3,34 14 000 59 1 990 x 1 750 x 880 540 ● ○ ●
662 67,3 66,2 3,26 18 000 61 1 990 x 2 300 x 880 685 ● ● ●
852 84,4 73,7 3,27 18 000 61 1 990 x 2 300 x 880 705 ● ● ●
932 94,9 86,3 3,64 21 000 61 1 990 x 2 640 x 880 745 ● ○ ●
UPU/OPU - chilled water air conditioners
10 9,9 9,3 38,26 2 200 51 1 990 x 750 x 600 125 — — ○
20 17,2 14,9 29,13 3 200 59 1 990 x 750 x 600 150 — — ○
30 30,0 27,8 30,00 7 000 56 1 990 x 860 x 880 245 — — ○
50 41,0 36,2 24,54 8 000 60 1 990 x 860 x 880 250 — — ●
60 52,8 47,4 22,75 12 000 67 1 990 x 1 410 x 880 270 — — ○
POA
70 63,1 54,2 24,17 12 000 68 1 990 x 1 410 x 880 280 — — ●
80 65,4 61,8 24,79 16 000 61 1 990 x 1 750 x 880 375 — — ○
110 80,0 73,0 24,17 18 000 62 1 990 x 1 750 x 880 410 — — ●
160 110,0 99,7 29,33 24 000 62 1 990 x 2 640 x 880 690 — — ●
220 160,0 146,0 24,17 36 000 65 1 990 x 3 495 x 880 810 — — ○

1) Performance refers to: intake air 24 °C-45%Rh; R410A refrigerant; condensing temperature 45 °C; water temperature 7/12 °C; external static pressure 30 Pa. The declared performance does not consider the
heat generated by the fans, which must be added to the thermal load of the system. 2) EER (energy efficiency ratio)= total cooling capacity / input power of compressors + input power of fans (excluding air-
cooled condensers). 3) Sound pressure levels at a distance of 2 m; in a free field; pursuant to UNI EN ISO 3744:2010.

G Series - Great
Perimetral and high efficiency solution for large data centers.
High delivered cooling capacity to footprint ratio.
Optimised air distribution in raised floor.
Direct expansion or Chilled water system.
Outdoor unit Cooling Sensible cooling EER 2) Air flow Sound pressure 3) Dimension Weight RRP
capacity 1) capacity 1)
HxWxD

kW kW m³/h dB(A) mm kg £
UGA - direct expansion air conditioners with air-cooled or water-cooled condensers
932 102,6 102,6 4,16 18 000 56 1 990 x 2 390 x 921 910
POA
1342 153,9 153,9 4,54 31 500 61 1 990 x 3 120 x 921 1 240
UGU - chilled water air conditioners
70 55,5 55,5 31,17 11 000 58 1 990 x 1 320 x 921 540
150 112,6 112,6 36,32 23 000 60 1 990 x 1 840 x 921 840
150 XH 129,7 129,7 36,94 26 000 62 2 350 x 1 840 x 1 050 865
POA
230 176,6 176,6 36,65 36 000 63 1 990 x 2 740 x 921 1 220
230 XH 220,7 220,7 38,86 39 000 65 2 350 x 2 740 x 1 050 1 250
300 202,8 202,8 33,97 45 200 62 1 990 x 4 020 x 921 1 630

1) Performance refers to: intake air 32 °C-30%Rh; R410A refrigerant; condensing temperature 45 °C; water temperature 12/20 °C; external static pressure 30 Pa. The declared performance does not consider
the heat generated by the fans, which must be added to the thermal load of the system. 2) EER (energy efficiency ratio)= total cooling capacity / input power of compressors + input power of fans (excluding air-
cooled condensers). 3) Sound pressure levels at a distance of 2 m; in a free field; pursuant to UNI EN ISO 3744:2010.

76
CLOSE CONTROL / VERTICAL DX INDEX CLOSE CONTROL UNITS
CHILLERS

Close Control units


R Series - In-Row
In-row solution.
Airflow distribution as close as possible to servers.
Rear suction from hot aisles and front delivery to cold aisles.
Direct expansion or chilled water system.

Outdoor unit Cooling Sensible EER 2) Air flow Sound Dimension Weight Water-cooled Two sources RRP
capacity 1) cooling pressure 3) free cooling
capacity 1) HxWxD

kW kW m³/h dB(A) mm kg £
HRA - direct expansion air conditioners with air-cooled or water-cooled condensers
121 11,4 11,4 3,70 3 200 51 1 970 x 300 x 1 200 220 ○ ○
201 22,0 19,9 3,52 3 600 53 1 970 x 300 x 1 200 235 ○ ○
POA
231 22,9 22,6 3,66 6 000 54 2 000 x 600 x 1 220 235 ● ●
361 36,6 34,7 3,91 6 000 56 2 000 x 600 x 1 220 235 ○ ○
HRU - chilled water air conditioners
20 24,5 24,5 23,09 5 600 53 1 970 x 300 x 1 200 145 ○
POA
40 37,3 37,3 27,82 9 000 62 2 000 x 600 x 1 220 210 ●

1) Performance refers to: intake air 32 °C-30%Rh; R410A refrigerant; condensing temperature 45 °C; water temperature 12/20 °C; external static pressure 30 Pa. The declared performance does not consider
the heat generated by the fans, which must be added to the thermal load of the system. 2) EER (energy efficiency ratio)= total cooling capacity / input power of compressors + input power of fans (excluding air-
cooled condensers). 3) Sound pressure levels at a distance of 2 m; in a free field; pursuant to UNI EN ISO 3744:2010.

W Series - Cold Wall


Technical corridor solution.
Zero data centers floor space occupied.
Very high EER (energy efficiency ratio) thanks to the optimised air flow.
Fully customizable according the data centers characteristics.
Outdoor unit Cooling capacity 1) Sensible cooling EER 2) Air flow Sound Dimension Weight RRP
capacity 1) pressure 3)
HxWxD

kW kW m³/h dB(A) mm kg £
HWU - chilled water air conditioners
2X1 112,0 112,0 18,60 25000 71 1 800 x 1 900 x 1 400 600
3X1 189,9 189,9 21,58 37500 72 1 800 x 2 850 x 1 400 900
4X1 258,9 258,9 22,32 50000 72 1 800 x 3 800 x 1 400 1 200
POA
2X2 224,0 224,0 18,60 50000 72 3 600 x 1 900 x 1 400 1 200
3X2 379,9 379,9 21,59 75000 74 3 600 x 2 850 x 1 400 1 800
4X2 500,5 500,5 23,50 96000 74 3 600 x 3 800 x 1 400 2 400

1) Performance refers to: intake air 40 °C-25%Rh; R410A refrigerant; condensing temperature 45 °C; water temperature 20/30 °C; external static pressure 30 Pa. The declared performance does not consider
the heat generated by the fans, which must be added to the thermal load of the system. (2) EER (Energy Efficiency Ratio) = total cooling capacity / input power of compressors + input power of fans (excluding
air-cooled condensers). (3) Sound pressure levels at a distance of 2 m; in a free field; pursuant to UNI EN ISO 3744:2010.

Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
77
VERTICAL DX UNITS GENERAL INDEX

Vertical DX units
T-XAR · R407C
Configuration: split system - indoor unit. UC outdoor condensing unit.
2 heating options: integrated electric or hot water coils. 3-speed fan motor.
Operation range: indoor temperature +13 to +22 °C (WB) and +17 to +32 °C (DB),
outdoor temperature +19 to +47 °C (DB).
Outdoor unit Cooling Air flow Static Sound Dimension RRP
capacity 1) pressure 2) pressure 3)
Treated air Fresh air (with accessory) LxWxH
Nominal Min / Max Nominal Normal speed
kW m³/h m³/h m³/h daPa dB(A) mm £
T-XAR - air cooled models
1 200 T-X1200.AR 12,3 2 000 1 500 / 2 500 180 0 / 13 51 890 x 430 x 1540
1 900 T-X1900.AR 16,2 3 200 2 500 / 3 800 285 0 / 21 56 1 000 x 500 x 1 735
2 450 T-X2450.AR 19, 8 4 500 3 600 / 5 400 420 0 / 20 59 1 300 x 600 x 1 840
POA
3 250 T-X3250.AR 29 ,0 5 800 4 600 / 7 000 500 0 / 25 65 1 530 x 600 x 1 830
4 650 T-X4650.AR 38 ,9 9 000 7 200 / 10 800 1 300 0 / 23 61 1 715 x 790 x 1 970
6 450 T-X6450.AR 55, 0 12 000 9 500 / 14 500 1 650 0 / 29 69 1 980 x 790 x 1 970

UC outdoor condensing Compatible with / number of necessary Air flow Input power Sound pressure 4) Dimension RRP
unit (accessory) outdoor unit(s)
LxWxH
m³/h W dB(A) mm £
UC34 X1200.AR / 1 8 600 530 52 885 x 825 x 840
UC54 X1900.AR / 1 7 600 611 53 885 x 825 x 840
POA
UC74 X2450.AR / 1 X4650.AR / 2 8 550 611 56 1 141 x 885 x 840
UC104 X3250.AR / 1 X6450.AR / 2 14 000 1 222 56 1 546 x 885 x 840

1) International standard ISO 51.51 conditions. 27 °C/19 °C (WB) - outside air : 35 °C/24 °C (WB). Wasted water: inlet +15 °C - recycled water inlet/outlet: 30 °C/35 °C. 2) Pressure in air flow range at nominal
voltage, without accessories. 3) Total sound pressure dB(A) (4 m) under nominal conditions in a room of 1 000 m³ (reverberation 0,83 s). 4) Total sound pressure dB(A) (4 m) under nominal conditions in free field
on reflecting surface.

Accessories and options Accessories and options


Air distribution duct frame ON / OFF switch and room thermostat
Electric heaters Pipe link 10 m - 1 circuit
Fresh air intake Remote fault reporting
Front air distribution plenum Set of female valves (mandatory)
High ventilation (provided as standard for sizes 1200 and 1900) Total rear intake duct frame
Hot water coil UC - outdoor condensing unit

Vertical air conditioners.


· Robust unit with mechanical control
· Easy installation and maintenance
· Small footprint casing
· Different air intake and discharge configurations
· Heating systems available (options)

UC - outdoor unit (accessory)

78
CLOSE CONTROL / VERTICAL DX INDEX VERTICALCHILLERS
DX UNITS

Vertical DX units
T-CX and T-XAO · R407C
Configuration: Mono-bloc system. 2 heating options: integrated electric or hot
water coils (hot water coil not available for CX25). 3-speed fan motor (2-speed
fan motor for CX25). Operation range: air temperature +15 to +23 °C (WB) and
+21 to +32 °C (DB), water temperature +10 to +34 °C.
Outdoor unit Cooling Air flow Static Sound Dimension RRP
capacity 1) pressure 2) pressure 3)
Treated air Fresh air (with accessory) LxWxH
Nominal Min / Max Nominal Normal speed
kW m³/h m³/h m³/h daPa dB(A) mm £
T-CX and T-XAO - water cooled models
25 T-CX25 8 ,0 1 500 1500 / 1750 — 0/8 — 800 x 407 x 1 280
1 200 T-X1200.AO 15, 0 2 000 1 500 / 2 500 180 0 / 13 51 890 x 430 x 1 540
1 900 T-X1900.AO 18 ,0 3 200 2 500 / 3 800 285 0 / 21 55 1 000 x 500 x 1 735
POA
2 450 T-X2450.AO 23 ,0 4 500 3 600 / 5 400 420 0 / 20 58 1 300 x 600 x 1 840
3 250 T-X3250.AO 32, 4 5 800 4 600 / 7 000 500 0 / 25 64 1 530 x 600 x 1 830
4 650 T-X4650.AO 45, 7 9 000 7 200 / 10 800 1 300 0 / 23 60 1 715 x 790 x 1 970

1) International standard ISO 51.51 conditions. 27 °C/19 °C (WB) - outside air : 35 °C/24 °C (WB). Wasted water: inlet +15 °C - recycled water inlet/outlet: 30 °C/35 °C. 2) Pressure in air flow range at nominal
voltage, without accessories. 3) Total sound pressure dB(A) (4 m) under nominal conditions in a room of 1 000 m³ (reverberation 0,83 s).

Accessories and options Accessories and options


Air distribution duct frame Hot water coil
Electric heaters ON / OFF switch and room thermostat
Fresh air intake Remote fault reporting
Front air distribution plenum Sump heating resistance
High ventilation (provided as standard for CX25, X1200.AO and X1900.AO) Total rear intake duct frame

Specifications subject to change without notice. For detailed information about ErP / Energy Labelling, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
79
GENERAL INDEX

CO2 condensing units -


CR Series with natural
refrigerant
Panasonic’s C02 condensing units - CR Series
provide the ideal solution for supermarkets,
convenience stores and gas stations.
Keeping food always fresh at right temperature in
showcases or cold rooms is a very critical point.
And one of the biggest challenges for those
retailers has been the expensive effects of
refrigeration breakdowns which can result in
costly product wastage.

80
REFRIGERATION

CR Series 20 HP MT/LT model. Easy and quick installation.


· Multi-compressor system Pressure release valves and a range of optional
· Smaller footprint accessories support fast and efficient installation.
· Maximum piping length of 100 m
· Cooling capacity can be controlled from 25 to 100% under
partial load CO2 service checker.
· Useful tool supporting daily technical tasks on the field
such as commissioning
CO2 transcritical condensing units - CR Series. · Reading and recording variable technical parameters
· Reliable quality - made in Japan · Monitoring an alarm status
· Set-points at medium or low temperature available
depending on applications
· 2-stage compressor with the split cycle for increased Design support tool available in Panasonic PRO Club.
efficiency · Supporting engineers and installers to make a quick
· High seasonal performance and high COP at high calculations when specifying the project
ambient temperature · Ready to work on all computers, tablets and
smartphones
Compact control panel and electric expansion valves https://www.panasonicproclub.com
(EEVs).
· A compact intelligent controller has the smart program
especially for cold rooms PACi NX Elite can cool rooms down to 8 °C.
· 7 different sizes EEVs are ready to meet precisely the PACi NX Elite offers a high quality and efficient solution for
field demand high temperature refrigeration applications for facilities
such as wine cellars, food processing facilities and
supermarkets.
Refer to page 31 in the Commercial section for more
details.
81
GENERAL INDEX

MT 4,0 kW 7,0 kW 8,0 kW 15,0 kW 16,0 kW 29,0 kW


Outdoor
units
LT 2,0 kW 4,0 kW 8,0 kW 15,0 kW

2 HP MT / LT
(200VF5A)

OCU-CR200VF5A
OCU-CR200VF5A-PRV

4 HP MT
(400VF8)

OCU-CR400VF8
OCU-CR400VF8-PRV

4 HP MT / LT
(400VF8A)

OCU-CR400VF8A
OCU-CR400VF8A-PRV

10 HP MT
(1000VF8)

OCU-CR1000VF8
OCU-CR1000VF8-PRV

10 HP MT / LT
(1000VF8A)

OCU-CR1000VF8A
OCU-CR1000VF8A-PRV

20 HP MT / LT
(2000VF8A)

OCU-CR2000VF8A
OCU-CR2000VF8A-PRV

82
REFRIGERATION INDEX REFRIGERATION

Superior cooling capacity at each evaporating temperature.


CO2 transcritical condensing units - CR Series have a high cooling capacity at each set point. The CO2 2-stage compressor
developed by Panasonic is designed to compress CO2 refrigerant twice; it reduces the load in operation by half (compared
to 1-stage refrigerant compression) and delivers increased durability and reliability.
Units can be programmed to run at low and medium temperatures at initial set-up. These settings can then be modified by
turning a simple and user friendly rotary switch to further enhance energy savings.

MT/LT Type: MT Type: 400VF8 - 7,5 kW.


200VF5A - 4 / 2 kW. MT/LT Type: 400VF8A - 8 / 4 kW.
3,83 SEPR cooling. 2,45 SEPR cooling.
1,92 SEPR freezing. 1,56 SEPR freezing.
* SEPR values has been tested at 3-part laboratory. * Model 400VF8A.

OCU-CR200VF5A(SL) 1). OCU-CR400VF8(SL) / OCU-CR400VF8A(SL) 2).


Cooling capacity (kW) Cooling capacity (kW)
5,0 10,0

4,0 8,0
OCU-CR400VF8
3,0 6,0
OCU-CR400VF8A
2,0 4,0

1,0 2,0

0 0
–50 –45 –40 –35 –30 –25 –20 –15 –10 –5 0 –50 –45 –40 –35 –30 –25 –20 –15 –10 –5 0

Evaporation temperature (ºC) Evaporation temperature (ºC)

MT Type: 1000VF8 - 15 kW. NEW MT/LT Type:


MT/LT Type: 1000VF8A - 16 / 8 kW. 2000VF8A - 29 / 15 kW.
2,86 SEPR cooling. 3,10 SEPR cooling.
1,49 SEPR freezing. 1,64 SEPR freezing.
* Model 1000VF8A.

OCU-CR1000VF8(SL) / OCU-CR1000VF8A(SL) 2). OCU-CR2000VF8A(SL) 1).


Cooling capacity (kW) Cooling capacity (kW)
20,0 35,0

30,0
15,0
25,0
OCU-CR1000VF8
OCU-CR1000VF8A 20,0
10,0
15,0

10,0
5,0
5,0

0 0
–50 –45 –40 –35 –30 –25 –20 –15 –10 –5 0 –50 –45 –40 –35 –30 –25 –20 –15 –10 –5 0

Evaporation temperature (ºC) Evaporation temperature (ºC)

1) Ambient temperature: 32 °C, 230 V, refrigerant: R744, suction gas temperature: 18 °C. 2) Ambient temperature: 32 °C, 400 V, refrigerant: R744, suction gas temperature:18 °C.

Superior efficiency with reliable quality Flexible installation

1 · Panasonic has combined the 2-stage compressor with the


split cycle for increased efficiency
· High seasonal performance. SEPR: Maximum 3,83 in
3 · Set-points at medium or low temperature
available depending on applications
· Compact unit
cooling, 1,92 in freezing 1) · Silent operation
· High COP at high ambient temperature · Long piping length: Maximum 100 m 2)
1) 200VF5A. · High external static pressure
· Transfer pressure control for stable
electric expansion valve control in
Heat recovery port 1) as renewable energy showcases 2)

2 · Maximum 16,7 kW 2) of heating for free


· Optional possibility to get subsidy (depending on location)
· Easy connection process
2) For models 1000VF8A and 2000VF8A.

1) For models 1000VF8A and 2000VF8A. 2) For model 1000VF8A.

83
GENERAL INDEX

CO2 condensing units - CR Series

Standard outdoor unit OCU-CR200VF5A OCU-CR400VF8 OCU-CR400VF8A


Outdoor unit with PRV Fitted OCU-CR200VF5A-PRV OCU-CR400VF8-PRV OCU-CR400VF8A-PRV
Type (MT: medium temperature, LT: low temperature) MT (4 kW) / LT (2 kW) MT (7,5 kW) MT (8 kW) / LT (4 kW)
Voltage V 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415
Power supply Phase Single phase Three phase Three phase
Frequency Hz 50 50 50
Cooling capacity at ET -10 °C AT 32 °C kW 3,70 6,89 7,52
Cooling capacity at ET -35 °C AT 32 °C kW 1,80 — 3,77
SEPR cooling at ET -10 °C AT 32 °C 3,83 3,17 3,20
SEPR freezing at ET -35 °C AT 32 °C 1,92 — 1,73
Annual electricity consumption at ET -10 °C AT 32 °C kWh/a 6 797 13 384 14 488
Annual electricity consumption at ET -35 °C AT 32 °C kWh/a 8 021 — 16 255
Evaporator connection Multiple Multiple Multiple
Evaporation temperature Min ~ Max °C -45 ~ -5 -20 ~ -5 -45 ~ -5
Ambient temperature Min ~ Max °C -20 ~ +43 -20 ~ +45 -20 ~ +45
Refrigerant R744 R744 R744
Design pressure liquid line Mpa 12 8 8
Design pressure suction line Mpa 8 8 8
User system external alarm. Digital input. Non-voltage contact Yes Yes Yes
Liquid tube electromagnetic valve Vac 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240
Showcase operation ON / OFF signal. Digital input. Non-voltage contact Yes Yes Yes
Modbus communication line (RS485) Ports Yes Yes Yes
Compressor type 2- stage rotary 2- stage rotary 2- stage rotary
Dimension HxWxD mm 930 x 900 x 437 948 x 1 143 x 609 948 x 1 143 x 609
Net weight Kg 70 136 149
Suction pipe Inch (mm) ⅜ (9,52) ½ (12,70) ½ (12,70)
Piping diameter 1)
Liquid pipe Inch (mm) ¼ (6,35) ⅜ (9,52) ⅜ (9,52)
Length of connection piping m 25 50 2) 50 2)
PED CAT Ι ΙΙ ΙΙ
Air flow m³/min 54 59 59
External static pressure Pa 17 50 50
Heat recovery port — — Yes
Ambient temperature °C 32 32 32
Evaporating temperature °C -10 -35 -10 -10 -35
Cooling capacity kW 3,70 1,80 6,89 7,52 3,77
Standard performance
Power consumption kW 1,79 1,65 4,00 4,51 3,69
Nominal load ampere A 7,94 7,26 6,14 7,20 6,20
Sound pressure dB(A) 35,5 3) 35,5 3) 33,0 4) 36,1 4) 36,1 4)
Necessary accessories
Drier filter liquid line, Ø6,35 mm D-152T / DCY-P12 Yes (included) Yes (included) Yes (included)
Drier filter liquid line, Ø15,88 mm D-155T / DCY-P8 — — —
Suction filter, Ø19,05 mm (outer Ø welding) S-008T / S-008T1 — Yes (included) Yes (included)
RRP £ 10,298/10,608 16,503 /16,999 22,568/23,245

1) These diameters correspond to the output of the unit. The required diameter must be calculated with Refrigeration designer available on PRO Club. 2) PZ-68S (refrigeration oil) must be added according to
Refrigeration designer available on PRO Club. 3) ET-10 °C, 65 S-1, 10 m from product. 4) ET-10 °C, 80 S-1, 10 m from product.

43 °C
CO2
5
YEARS
HIGH EFFICIENCY AMBIENT ANTI CORROSION HEAT RECOVERY COMPRESSOR BMS
R744 COMPRESSOR SUPER QUIET TEMPERATURE COATING PORT AUTOMATIC FAN WARRANTY CONNECTIVITY

84
REFRIGERATION INDEX REFRIGERATION

Standard outdoor unit OCU-CR1000VF8 OCU-CR1000VF8A OCU-CR2000VF8A


Outdoor unit with PRV Fitted OCU-CR1000VF8-PRV OCU-CR1000VF8A-PRV OCU-CR2000VF8A-PRV
Type (MT: medium temperature, LT: low temperature) MT (15 kW) MT (16 kW) / LT (8 kW) MT (29 kW) / LT (15 kW)
Voltage V 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415
Power supply Phase Three phase Three phase Three phase
Frequency Hz 50 50 50
Cooling capacity at ET -10 °C AT 32 °C kW 14,00 15,10 28,70
Cooling capacity at ET -35 °C AT 32 °C kW — 8,00 14,70
SEPR cooling at ET -10 °C AT 32 °C 2,62 2,86 3,14
SEPR freezing at ET -35 °C AT 32 °C — 1,49 1,64
Annual electricity consumption at ET -10 °C AT 32 °C kWh/a 32 815 32 409 56 306
Annual electricity consumption at ET -35 °C AT 32 °C kWh/a — 39 985 66 660
Evaporator connection Multiple Multiple Multiple
Evaporation temperature Min ~ Max °C -20 ~ -5 -45 ~ -5 -45 ~ -5
Ambient temperature Min ~ Max °C -20 ~ +43 -20 ~ +43 -20 ~ +45
Refrigerant R744 R744 R744
Design pressure liquid line Mpa 8 8 8
Design pressure suction line Mpa 8 8 8
User system external alarm. Digital input. Non-voltage contact Yes Yes Yes
Liquid tube electromagnetic valve Vac 220 / 230 / 240 220 / 230 / 240 —
Showcase operation ON / OFF signal. Digital input. Non-voltage contact Yes Yes Yes
Modbus communication line (RS485) Ports Yes Yes Yes
Compressor type 2- stage rotary 2- stage rotary 2- stage rotary
Dimension HxWxD mm 1 941 x 890 x 890 1 941 x 890 x 890 1 941 x 1 190 x 890
Net weight Kg 293 320 494
Suction pipe Inch (mm) 50,833¾ (19,05) ¾ (19,05) 1 1/8 (28.58) and ⅞ (22,22)
Piping diameter 1)
Liquid pipe Inch (mm) ⅝ (15,88) ⅝ (15,88) ¾ (19,05)
Length of connection piping m 100 2) 100 2) 100 2)
PED CAT ΙΙ ΙΙ ΙΙ
Air flow m³/min 220 220 220
External static pressure Pa 58 58 58
Heat recovery port — Yes Yes
Ambient temperature °C 32 32 32
Evaporating temperature °C -10 -10 -35 -10 -35
Cooling capacity kW 14,00 15,10 8,00 28,70 14,70
Standard performance
Power consumption kW 8,20 8,20 7,57 15,70 13,45
Nominal load ampere A 12,60 12,60 11,60 24,31 20,49
Sound pressure dB(A) 36,0 3) 36,0 3) 36,0 3) 42,0 3) 42,0 3)
Necessary accessories
Drier filter liquid line, Ø6,35 mm D-152T / DCY-P12 — — —
Drier filter liquid line, Ø15,88 mm D-155T / DCY-P8 Yes (included) Yes (included) Yes (included)
Suction filter, Ø19,05 mm (outer Ø welding) S-008T / S-008T1 Yes (included) Yes (included) Yes (included)
RRP £ 26,460/27,253 29,902/30,800 50,833/52,359

1) These diameters correspond to the output of the unit. The required diameter must be calculated with Refrigeration designer available on PRO Club. 2) PZ-68S (refrigeration oil) must be added if >50 m. 3) ET
-10 °C, 60 S-1, 10 m from product.

45 °C
CO2
5
YEARS
HIGH EFFICIENCY AMBIENT ANTI CORROSION HEAT RECOVERY COMPRESSOR BMS
R744 COMPRESSOR SUPER QUIET TEMPERATURE COATING PORT AUTOMATIC FAN WARRANTY CONNECTIVITY

85
GENERAL INDEX

Showcases.
Convenience stores, supermarkets, gas-stations.
Open showcase Walk-in refrigerator Reach-in freezer

OCU-CR1000VF8
OCU-CR1000VF8A
* * * * *
Dessert showcase

* OCU-CR200VF5A

* Controllers: PAW-CO2-PANEL-C or local supply.

Cold room application to keep food fresh


Multiple installation capabilities. Unparalleled flexibility:
· Food retail applications (convenience store,
supermarkets, gas-stations)
· Food service applications (restaurants, canteens, schools)
· Non-food applications (warehousing, industrial storage,
healthcare)

Cold room application integrated with PACi NX Series


Panasonic offers various solutions for cold rooms by combining a wide range of products.
Integrated with PACi NX Series, it allows for flexible design and installation.

1 2
R32
REFRIGERANT

CO2 condensing units - CR Series for refrigerated room. PACi NX Series for cooling rooms between 8 °C WB and 24 °C WB.

PACi NX: 8 °C WB
and 24 °C WB

CO2: < +5 °C DB 2

86
REFRIGERATION INDEX REFRIGERATION

Control panel and electric expansion valves RRP £

Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-03 1,992


probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V03CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-05 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V05CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-09 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V09CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-11 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V11CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-14 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V14CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-18 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V18CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-24 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E2V24CWAC0.
Panel-C + MPXPRO control, stator, KIT-CO2-PANEL-C-30 1,992
probes, etc + EEV ⅜” (9,52) ODF high
pressure, size E3V30CWM00.

Accessories RRP £

Service adaptor for vacuum and SPK-TU125 194


service (HP and LP port) for all
outdoor units*.
Lubrication Oil PZ-68S (0,5L) for all CZ-CO2LBROL500 114
outdoor units**.

CO2 service checker RRP £

CO2 service checker for PAW-CO2-CHECKER 569


commissioning, maintenance and
troubleshooting.

* 2 pcs. are recommended for the 2000VF8A. ** You can find the PZ-68S oil “Safety Sheet” in the
SAFETY section of our pipe selection software, available on our PRO Club platform.

Compatibility relationship: 1) and 2) are compatible; 3) and 4) are compatible; 5) and 6) are
compatible.
Stock availability: 1), 3) and 5) until end of stock.

Refrigeration designer available


in Panasonic PRO Club.
This easy to use design tool supports
engineers, installers, and technicians to make a
quick calculation for commercial refrigeration
systems.

· Evaporation temperature selection


· Cooling capacity calculator
· Refrigerant pipe calculation
· Electric expansion valves calculation
· Refrigerant amount calculation

Ready to work on all devices, computers, tablets and www.panasonicproclub.com or


smartphones!! connect simply with your smartphone
to the PRO Club using this QR

87
Legacy Sanyo replacement technology from Panasonic

GHP - J2 - 2-Pipe VRF - Mini ECOi


Sanyo model Panasonic model Sanyo reference Panasonic equivalent
SGP-E70J2GU2 No equivalent SPW-CR365GX(H)56(B) U-4LE2E5
SGP-E90J2GU2 No equivalent SPW-CR485GX(H)56(B) U-5LE2E5
SGP-E120J2GU2 No equivalent SPW-CR605GX(H)56(B) U-6LE2E5
SGP-E150J2GU2 U-16GE3E5 SPW-CR365GXH8B U-4LE2E8
SGP-E190J2GU2 U-20GE3E5 SPW-CR485GXH8B U-5LE2E8
SPW-CR605GXH8B U-6LE2E8

GHP - K1 - 2-Pipe
Sanyo model Panasonic model VRF - 6 Series 2-Pipe
SGP-E70K1GU2 No equivalent Sanyo reference Panasonic equivalent
SGP-E90K1GU2 No equivalent SPW-C0706DXH8 U-8ME2E8
SGP-E120K1GU2W No equivalent SPW-C0906DXH8 U-10ME2E8
SGP-E150K1GU2W U-16GE3E5 SPW-C1156DXH8 U-12ME2E8
SGP-E190K1GU2W U-20GE3E5 SPW-C1306DXH8 U-14ME2E8
SGP-E240K1GU2W U-25GE3E5 SPW-C1406DXH8 U-16ME2E8
SPW-C1606DXH8 U-18ME2E8
SPW-C1806DXH8 U-20ME2E8
GHP - M2 - 2-Pipe
Sanyo model Panasonic model
SGP-EW150M2G2W U-16GE3E5 VRF - 5 Series 2-Pipe
SGP-EW190M2G2W U-20GE3E5 Sanyo reference Panasonic equivalent
SGP-EW240M2G2W U-25GE3E5 SPW-C0705DXHN8 U-8ME2E8
SPW-C0905DXHN8 U-10ME2E8
SPW-C1155DXHN8 U-12ME2E8
GHP - J2 - 3-Pipe
SPW-C1305DXHN8 U-14ME2E8
Sanyo model Panasonic model
SPW-C1405DXHN8 U-16ME2E8
SGP-EZ190J2GU2 U-20GF3E5

VRF - 5 Series outdoor units - 3-Pipe


GHP - K1 - 3-Pipe
Sanyo reference Panasonic equivalent
Sanyo model Panasonic model
SPW-C0705DZH8 U-8MF3E8
SGP-EZ190K1GU2 U-20GF3E5
SPW-C0905DZH8 U-10MF3E8
SPW-C1155DZH8 U-12MF3E8
GHP - M2 - 3-Pipe SPW-C1305DZH8 U-14MF3E8
Sanyo model Panasonic model SPW-C1405DZH8 U-16MF3E8
SGP-EW120M2G2W No equivalent Please be advised that when replacing Sanyo outdoor unit with any U-**MF3E8 outdoor unit. It is
necessary to take into consideration that the discharge pipe length is required for additional
SGP-EZ150M2G2 U-16GF3E5 refrigerant charge.
SGP-EZ190M2G2 U-20GF3E5
SGP-EZ240M2G2 U-25GF3E5

GHP - ECO G Power


Sanyo model Panasonic model
SGP-EGW190M2G2W No equivalent

VRF - indoor units


Cassette 90x90 Hide-away Ceiling Wall-mounted
X***XH U***XH T***XH K***XH
Model size
XDR***GXH56 UR***GXH56 TDR***GXH56 KR***GXH56
XDR***GXH56 UR***GXH56 TDR***GXH56 KR***GXH56
74 / 75 / 76 S-22MU2E5B S-22MF3E5A — S-22MK2E5B
94 / 95 / 96 S-28MU2E5B S-28MF3E5A — S-28MK2E5B
124 / 125 / 126 S-36MU2E5B S-36MF3E5A S-36MT2E5A S-36MK2E5B
164 / 165 / 166 S-45MU2E5B S-45MF3E5A S-45MT2E5A S-45MK2E5B
184 / 185 / 186 S-56MU2E5B S-56MF3E5A S-56MT2E5A S-56MK2E5B
254 / 255 / 256 S-73MU2E5B S-73MF3E5A S-73MT2E5A S-73MK2E5B
364 / 365 / 366 S-106MU2E5B S-106MF3E5A S-106MT2E5A S-106MK2E5B
484 / 485 / 486 S-140MU2E5B S-140MF3E5A S-140MT2E5A —
604 / 605 / 606 S-160MU2E5B S-160MF3E5A — —

4 & 5 series indoor units: Above is a table showing the current Panasonic equivalent for each Sanyo indoor model. Indoor units can be added or replaced without any setting changes.
Please note there have been design changes therefore dimensions and appearances will not be the same. Please check in technical manual.
3 series indoor units: When using a current Panasonic R410A outdoor and mixing the current Panasonic indoors with 3 series Sanyo indoor units on the same system, you will need to access the detailed
settings to change code 15 to 0029 on the Sanyo indoor units.

88
EDITORIAL

In almost all circumstances it is possible to replace old Sanyo units with current
Panasonic models however, each Sanyo generation has different criteria to
consider when replacing. Below we have outlined how to replace each generation.

VRF - 4 Series outdoor units - 3-Pipe Local and system controls


Sanyo reference Panasonic equivalent Controls Sanyo reference Panasonic equivalent
SPW-CR704GDZH8 U-8MF3E8 Wired remote controller RCS-TM80BG CZ-RTC5B
SPW-CR904GDZH8 U-10MF3E8 Schedule timer SHA-TM64AGB CZ-ESWC2
SPW-CR1154GDZH8 U-12MF3E8 System controller SHA-KC64AGB CZ-64ESMC2
SPW-CR1304GDZH8 U-14MF3E8 ON / OFF controller SHA-KC16KAGB CZ-ANC2
SPW-CR1404GDZH8 U-16MF3E8 Intelligent controller SHA-KT256EG CZ-256ESMC3
SPW-CR704GDZH8B U-8MF3E8 Communication adaptor connector SHA-KA128AGB CZ-CFUNC2
SPW-CR904GDZH8B U-10MF3E8 Seri-Para I/O unit for outdoor ACC-XSP4U1GB CZ-CAPDC2
SPW-CR1154GDZH8B U-12MF3E8 Interface adaptor SHA-KL4UGB CZ-CAPC2
SPW-CR1304GDZH8B U-14MF3E8 Seri-Para I/O unit for each I/U ACC-SP1AGB CZ-CAPBC2
SPW-CR1404GDZH8B U-16MF3E8 LonWorks® interface SHA-LN16UGB CZ-CLNC2
Please be advised that when replacing Sanyo outdoor unit with any U-**MF3E8 outdoor unit. It is Web interface SHA-KW64EG CZ-CWEBC2
necessary to take into consideration that the discharge pipe length is required for additional
refrigerant charge. All local controls work via the same 2 core cable as current Panasonic controllers meaning they can
easily be replaced for new controllers. The appearance of the new Panasonic controls have changed
and also not all of the new features will work on existing Sanyo equipment (i.e. energy monitoring
on CZ-RTC5B).
The same applies for system controls and other interfaces which operate using 2 core
VRF - 3 Series 3-Pipe - R407c communications (U1,U2) therefore new replacements are compatible just some of the new features
Sanyo reference Panasonic equivalent may not be available.

SPW-CR703GZH8 U-8MF3E8
SPW-CR903GZH8 U-10MF3E8 Heat Recovery Boxes
This generation runs on R407c refrigerant so it is always best practice to replace all equipment and Sanyo reference Panasonic equivalent
take advantage of Panasonic’s renewal technologies.
However in situations where this is not feasible then it is possible to replace indoors and also ATK-RZP56BGWB CZ-P56HR3
outdoor units with conditions. When carrying out these replacements it is particularly important to
check the wall thickness and integrity of the pipework is appropriate for re-use and that standard ATK-RZP56BG CZ-P56HR3
renewal procedures are followed. ATK-ZP80UG CZ-P56HR3
NOTE: The new R410A system will run at a lot higher pressure than the existing R407c system ATK-RZP160BGWB CZ-P160HR3
therefore it is necessary to change a setting on the outdoor unit which will restrict the running
pressure to the lower value associated with R407c refrigerant. As a further fail safe it is ATK-RZP160BG CZ-P160HR3
recommended to replace the high pressure switch, the part number for this is
CZ-PSWK2.
ATK-ZP140UG CZ-P160HR3
ACC-3WAY-AGB CZ-CAPE2
Please be advised that when replacing Sanyo outdoor unit with any U-**MF3E8 outdoor unit. It is
necessary to take into consideration that the discharge pipe length is required for additional ACC-3WAY-AG CZ-CAPE2
refrigerant charge.
CR-3WAY-TG CZ-CAPE2
Care must be taken when replacing SVK boxes due to variation of wirings. The Sanyo kit used a
cable with additional connectors. Please check wiring and spare parts for differences.

The above is for guidance only, please contact you usual sales representative before proceeding
with Sanyo replacement for up to date advise.

Cassette 60x60 Floor Chassis Slim hide-away 1 way cassette 2 way cassette
XM***XH FR***GXH56 FMR***GXH56 US***XH LDR***GXH56 —
XMR***EXH56 FR***GXH56 FMR***GXH56 FUR***EXH56 LDR***GXH56 —
— FR***GXH56 FMR***GXH56 — LDR***GXH56 SR***GXH56
S-22MY3E S-22MP1E5 S-22MR1E5 S-22MM1E5B — S-22ML1E5
S-28MY3E S-28MP1E5 S-28MR1E5 S-28MM1E5B S-28MD1E5 S-28ML1E5
S-36MY3E S-36MP1E5 S-36MR1E5 S-36MM1E5B S-36MD1E5 S-36ML1E5
S-45MY3E S-45MP1E5 S-45MR1E5 S-45MM1E5B S-45MD1E5 S-45ML1E5
S-56MY3E S-56MP1E5 S-56MR1E5 S-56MM1E5B S-56MD1E5 S-56ML1E5
— S-71MP1E5 S-71MR1E5 — S-73MD1E5 S-73ML1E5
— — — — — —
— — — — — —
— — — — — —

To amend the setting you will need a standard controller CZ-RTC4 or CZ-RTC5 and a maintenance cable PAW-MRC which allows you to plug the controller on the outdoor PCB.
Once connected follow the procedure below to change the code.

Please contact Panasonic Technical Department before proceeding.

89
6
10 Amp fuse for non NX units (high
Additional Accessories RRP £
static ducted).
PAW-UK-PACi-10A

49 21
10 metre flow box extension lead. PAW-UK-FLOW-EXT10 Power supply for Intesis. PAW-UK-INT-PWR

67 25
25 metre flow box extension lead. PAW-UK-FLOW-EXT25 Power supply for Smart Cloud router. PAW-UK-SMCL-PWR

589 14
PAW-UK-HEATER- Back box for heat recovery unit remote
Pre-heater kit for model 250 - 350. PAW-UK-HRV-RC-BOX
KIT1 controller.

641 3,450
PAW-UK-HEATER-
Pre-heater kit for model 500. KIT2
Units with 1 fan stripdown. SVC-VRF-SD1

641 3,450
PAW-UK-HEATER-
Pre-heater kit for model 800 - 1000. KIT3
Units with 2 fans stripdown. SVC-VRF-SD2

50 3,450
PACi unit fan interface including relay. PAW-UK-SMF1 PACi units stripdown. SVC-PAC-SD

29
RAC unit return air sensor extension. PAW-UK-RACSENSOR

239
Leak detector - curved white - 2 relay. PAW-UK-LD-RD-CW2

248
Leak detector - stainless steel - 2
PAW-UK-LD-RD-SS2
relay.

228
Leak detector - white - 2 relay. PAW-UK-LD-RD-W2

67
Single leak detector power supply. PAW-UK-RD-em-PS2

216
4 way leak detector power supply. PAW-UK-RD-em-PS4

3
Plastic flushmount 47 mm back box PAW-UK-PC3RDEM-
for leak detector (rd-em). FMBB

2,081
IMEC - rad 32 channel leak detector
PAW-UK-IMEC-RAD32
monitoring unit.

3,364
IMEC - rad 64 channel leak detector
PAW-UK-IMEC-RAD64
monitoring unit.

451
Test kit case + ancillary equipment. PAW-UK-LD-Test-Kit

423
Test gas (10,000 ppm R410A in air). PAW-UK-LD-Test-Gas

66
Outlet plenum - S-3650PF3E & MF3
PAW-UK-NXPF-2DUCT
indoor sizes 15, 22, 28, 36 & 50.

150
Inlet plenum - S-3650PF3E & MF3 PAW-UK-NXPF-
indoor sizes 15, 22, 28, 36 & 50. 2DUCTRETURN

89
Outlet plenum - S-6071PF3E & MF3
PAW-UK-NXPF-3DUCT
indoor sizes 60, 73, & 90.

164
Inlet plenum - S-6071PF3E & MF3 PAW-UK-NXPF-
indoor sizes 60, 73, & 90. 3DUCTRETURN

110
Outlet plenum - S-1014PF3E & MF3
PAW-UK-NXPF-4DUCT
indoor sizes 106, 140, & 160.

212
Inlet plenum - S-1014PF3E & MF3 PAW-UK-NXPF-
indoor sizes 106, 140, & 160. 4DUCTRETURN

6
5 Amp fuse for non NX units. PAW-UK-PACi-5A

90
ACCESSORIES
EDITORIAL

282
Webserver airzone cloud Wi-Fi & PAW-UK-
Airzone Accessories RRP £
ethernet. AZX6WSPHUB

250
Airzone blueface zero thermostat PAW-UK-
white 8Z (CE6). AZCE6BLUEZEROCB

250
Airzone blueface zero thermostat PAW-UK-
wired black 8Z (CE6). AZCE6BLUEZEROCN

344
PAW-UK-
Airzone flexa 3.0 Main board 6Z. AZCE6FLEXA3

173
PAW-UK-
Airzone lite thermostat wired (white). AZCE6LITECB

173
PAW-UK-
Airzone lite thermostat wired (black). AZCE6LITECN

216
Airzone lite wireless thermostat PAW-UK-
(white). AZCE6LITERB

216
Airzone lite wireless thermostat PAW-UK-
(black). AZCE6LITERN

164
Airzone think thermostat wired PAW-UK-
(white). AZCE6THINKCB

255
Airzone think monochrome wireless PAW-UK-
thermostat (white). AZCE6THINKRB

255
Airzone think monochrome thermostat PAW-UK-
wireless (black). AZCE6THINKRN

1,432
Airzone medium plenum 4x 200 mm PAW-UK-
spigots. AZE25PANBS08L4

1,528
Airzone medium plenum 5x 200 mm PAW-UK-
spigots. AZE25PANBS08L5

Airzone Easyzone medium discharge 1,432


PAW-UK-
plenum 4x 200 mm spigots to suit AZE25PANBS08M4
S-6071PF3 (no fa connection).
Airzone Easyzone medium discharge 1,343
PAW-UK-
plenum 3x 200 mm spigots to suit AZE25PANBS08S3
S-3650PF3 (no fa connection).
Airzone Easyzone standard discharge 1,432
PAW-UK-
plenum 4x 200 mm spigots to suit AZE25PANBS08S4
S-3650PF3 (no fa connection).
Airzone Easyzone standard discharge 1,528
PAW-UK-
plenum 5x 200 mm spigots (fa AZE25PANST08L5
connection).
Airzone Easyzone standard discharge 1,623
PAW-UK-
plenum 6x 200 mm spigots (fa AZE25PANST08L6
connection).
Airzone Easyzone standard discharge 1,343
PAW-UK-
plenum 3x 200 mm spigots to suit AZE25PANST08S3
S-3650PF3 (fa connection).
Airzone Easyzone standard discharge 1,432
PAW-UK-
plenum 4x 200 mm spigots to suit AZE25PANST08S4
S-3650PF3 (fa connection).
107
X6 comun - cable bus Airzone PAW-UK-
(2x 0,5 + 2x 0,22) 100 m. AZX6CABLEBUS100

23
Airzone shielded bus cable 2x 0.22 + PAW-UK-
2x 0.5 (15 m). AZX6CABLEBUS15

107
Airzone 2x 0.75 red-black cable PAW-UK-
(100 m). AZX6CABLERN100

282
Airzone Panasonic controller gateway. PAW-UK-AZX6GTCPAN

235
PAW-UK-
Webserver Airzone cloud Wi-Fi. AZX6WSC5GER

91
Warranty terms and conditions
Please speak to us about on site training courses.

3 5 7

The Standard warranty The Extended warranty The Extended+ warranty


3 years parts and labour 5 years parts and labour. 7 years parts and labour.
(A2W exc. Labour). · The unit should be installed by a · The unit should be installed by a
· The unit should be installed by a competent person competent person
competent person · The installation instructions · The installation instructions supplied
· The installation instructions supplied with the unit must be with the unit must be followed
supplied with the unit must be followed · Annual maintenance records must
followed · Annual maintenance records must be kept
· Annual maintenance records must be kept · The installer must be a current
be kept · The installer must have completed PRO Partner or Elite PRO Partner
the relevant Panasonic training and must have completed the
· The installer must register the unit relevant Panasonic training
on PRO Club (VRF and A2W units · The Installer must register the unit
require additional commissioning on PRO Club (VRF and A2W units
documentation uploading onto require additional commissioning
PRO Club) documentation uploading onto
PRO Club
· A2W units must be installed with a
CZ-TAW1C adapter

* CZ-TAW1B Installation is mandatory on all Air to Water installations for 7 year warranty to be granted. For retrofit installations, the CZ-TAW1B must be installed and the smart cloud service activated. For new
build installations, smart cloud activation is not mandatory for the 7 year warranty to be granted.

Where do I register my unit for warranty?


Warranty registration can be completed through the PRO Club platform, or for
PRO Partners via the 24 hour support centre via e-mail: propartner.uk@eu.panasonic.com
or phone 01189 287 569.

Spare parts ordering - in warranty requests.


· Ring the air to water technical service support line on: 01707 378670 to diagnose the issue
and receive a warranty request code
· Receive and complete the in warranty spare parts form as provided by the technical team
· Complete and return the form to the following inbox: uk-aircon-service@eu.panasonic.com
· The spare part request is processed and the item(s) distributed

Our commitment to quality extends far beyond our products, which is why we
have developed a partner scheme designed to support installers who love our
solutions as much as we do.
To find out more about how you can become a Panasonic PRO Partner and have accesses to
a complete range of benefits including extended warranty, business support and reward
points, click on the link below:
www.aircon.panasonic.eu/GB_en/propartner

92
PROEDITORIAL
PARTNER

Panasonic PRO Partner scheme


Scheme overview
Designed to support the business development of installers who continually choose the quality and innovation of our
professional and residential solutions, the Panasonic PRO Partner scheme offers an extensive range of rewards, from
extended warranties to business support of up to £800. Our commitment to quality extends far beyond our products, which
is why we have developed a partner scheme designed to support installers who value our solutions.

The scheme is divided into two exclusive tiers, each offering a unique set of rewards to installers that trust the quality and
reliability of Panasonic Heating & Cooling Solutions.

To be eligible for PRO Partner status, installers must be To become an Elite PRO Partner, installers must be true
committed to selling Panasonic products and must complete advocates of Panasonic Heating & Cooling Solutions, this
Panasonic face-to-face training based in one of our UK training includes completion of our face-to-face training courses in one
centres. of our UK training centres.
· Extended warranty of up to 7 years, subject to conditions · Extended warranty up to 7 years, subject to conditions
· Reward points that can be exchanged for electronic goods, tools, · Enhanced reward points that can be exchanged for electronic
clothing, merchandise and more goods, tools, clothing, merchandise and more
· Increased business visibility through our installer finder network, · Increased business visibility and boosted sales through our
listed as a PRO Partner installer finder network listed as an Elite PRO Partner
· Business support fund · Enhanced Business support fund

Benefits
The PRO Partner scheme offers a myriad of benefits to enhance business opportunities
for ambitious installers that are passionate about our products.

Increased visibility on PRO Club. PRO Partner rewards portal. Business support fund.
The unique i-Finder feature available with With each of our exclusive PRO Partner To support installers, and businesses, we
our PRO Partner membership helps to tiers, members can earn points on their offer PRO and Elite PRO Partners an
provide online exposure for installers on installations which can be exchanged for incredible business support package. This
our network of worldclass heating and Panasonic branded merchandise, clothing is designed to further the growth and
cooling industry professionals. and more*. success of installers’ businesses with
personalised sales literature, industry
memberships, training courses and beyond.

24hr business support centre


As part of our commitment to support our installers with the PRO Partner scheme, we aim to ensure that the
administration is as easy as possible for our installers. Find support with your commissioning forms, warranty
registrations and general PRO Partner queries through our dedicated support centre.

*To begin earning points for installations, members of the PRO Partner Scheme must register their Panasonic unit on our PRO Club platform to
begin earning points and subsequent Panasonic rewards.

93
Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

94
EDITORIAL

Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

95
Panasonic service
Our Panasonic Service teams are committed to ensuring your peace of mind. Best service is our aim.
Panasonic provides a team of highly trained technicians and engineers to deliver professional and responsive services that
meet the highest levels of quality and safety while being efficient and cost effective.
To find out more about Panasonic Heating & Cooling Solutions, please visit www.aircon.panasonic.eu.

Maintenance. Repair. Warranty.


To meet the requirements of the standard Panasonic offers a wide range of service In accordance with the regulations,
warranty, the product must be maintained agreements, like Panasonic Service+ for a Panasonic guarantees its products against
and serviced annually by a suitably trained maximised product lifetime. Leave the care hidden defects. Moreover, Panasonic grants
and qualified engineer. This way we can of your Panasonic products to the experts. to the professional purchaser a commercial
extend the lifetime of the product. In the unlikely event that something goes warranty, specific to the product families,
wrong, trust one of our qualified and subject to compliance of all the rules of
Panasonic trained experts to get things installation and use of its products.
back on track.

Panasonic Heating & Cooling Solutions


customer service
Panasonic enables different channels for end users or professionals to get in touch with us:

Use our European website www.aircon.panasonic.eu for contacting us.


Panasonic has implemented a contact page on the Panasonic Heating & Cooling Solutions
website for potential or existing Panasonic customers.

Another option is to contact the highly experienced teams at the Panasonic customer service center, who
are more than qualified to support Panasonic clients in 13 different languages across Europe.

Our service center for United Kingdom end customers:


0808 208 2115
Mo-Fr 9-17h

96
WWW.AIRCON.PANASONIC.EU
www.eggeassociats.net
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without
prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic Marketing Europe GmbH.

Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the
damage and deterioration in safety due to usage of the other refrigerant.
The outdoor units in this catalogue contains fluorinated greenhouse gases with a GWP higher than 150.
To find out how Panasonic cares for you, log on to:
www.panasonic.co.uk/aircon

General requests:
Email: uk-aircon@eu.panasonic.com

Sales administration team:


Email: sales.PHVACUK@eu.panasonic.com

Technical service team:


Email: technical.PHVACUK@eu.panasonic.com
UK Office : +44 (0) 1707 378670
EU-PLST1224/01

Panasonic Heating & Ventilation Air-Conditioning UK Ltd.


Registered Office: Ground Floor, Building 3, Albany Place, Hyde Way,
Welwyn Garden City, Hertfordshire AL7 3BT
Company Registration: 02371708

You might also like