NITROGEN GAS GENERATOR
Generatore di azoto
50
N2-TOWER PLUS
The new series of Nitrogen generator modules La nuova serie di generatori N2-TOWER Plus
N2-TOWER Plus produces high purity garantiscono alta purezza per la maggior parte
di
Nitrogen for all major applications in
applicazioni del laboratorio analitico.
analytical laboratories. Nitrogen generators
Specificamente progettati per eliminare
eliminate the typical problems associated with
le problematiche tipiche dell’uso delle
the handling of high pressure gastanks and
bombole garantiscono un buon risparmio
they reduce the cost for high purity Nitrogen
economico
immediately.
nel medio termine.
The N2-TOWER Plus series of Nitrogen
La serie N2-TOWER Plus rimuove
generators use air from a separate compressor
l’ossigeno dall’aria generata dal
and remove the Oxygen to less than 10ppm
compressore esterno sino a valori inferiori a
(hydrocarbons to
10ppm (idrocarburi a valori inferiori
<0.1ppm is optional). The guaranteed flow
a 0,1 ppm con apposita opzione).
rates of pure Nitrogen are 200 ml / min, 500
I modelli disponibili garantiscono flussi
ml / min, 750 ml / min, 1300 ml / min or 4000
Di 200 ml / min 500 ml / min, 750 ml /
ml / min depending on the generator module.
min,1300 ml / min, 4000 ml / min
51
NITROGEN GAS GENERATOR | Generatore di azoto
N2-TOWER Plus
SPECIFICATIONS CARATTERISTICHE
LED-display for status Display LED per il controllo del corretto
Maintenance control funzionamento Necessita di un semplice Kit
light manutenzione a 4000h Semplicità rimozione filtri
senza dover aprire lo strumento ALLARMI
Alarms for: Catalyst duration, Catalyst temperature,
pressione, durata forno catalitico (opzione), temperatura
pressure Simple removal of filters without the need to
open instrument
APPLICAZIONI
APPLICATIONS • GC-Carrier Gas e Make-Up Gas
• GC-Carrier Gas and Make-Up Gas • ICP / HPLC-ELSD
• ICP / HPLC-ELSD • GC / FTIR
• GC / FTIR • Incubatori
• Incubators • TGA-DSC
• TGA-DSC
BENEFITS VANTAGGI
The constant high purity of the Nitrogen provides La costante purezza dell’azoto prodotto migliora la
stable conditions for analytical systems and stabilità del sistema analitico e assicura la riproducibilità
guarantees highly reproducible results. dei risultati.
The investment for the Nitrogen generator is Il costo del generatore viene mediamente ammortizzato
recuperated in about one year since there is no extra in poco più di un anno d’utilizzo eliminando costose
cost anymore for handling, transporting, storing and linee di trasporto del gas, la sostituzione delle bombole
purchasing the high pressure gastanks. oltre
al bunker di stoccaggio.
The installation is very simple and quick as is the
routine maintenance. L’installazione è semplice ed immediata
come le manutenzioni di routine.
N2TOWER N2TOWER N2-TOWER N2-TOWER N2-TOWER
MODELS modelli
200 500 750 1300 4000
Flow Nml / min. 200 500 750 1300 4000
Weight (kg) 10 10 10 15 15
Purity 99,999% 99,999% 99,995% 99,99% 99%
Delivery pressure Up to 5 barg (75 Psig)
Input pressure for model without compressor 7 min - 10 barg max (110-145 PSI) / Non condensing and oil free Air
N2 purity 0.1 ppm Total Hydrocarbons (if Option is installed) < -50°C DP (-58°F)
Sound level Noiseless (external compressor)
Particle filtration level 50 µm
Inlet: 1 / 8’’ G thread with 6mm tube rapid fitting Outlet: 1/8” G thread with 4mm tube rapid
Fittings
fitting
Pressure setting, system status, LED RGB display
User interface
Dimensions (mm) 140W x 630D x 490H
Power consumptions 20W - 270W with catalytic oven
Power requirements 110-120V 60Hz / 220-240V 50Hz
52
Generatore di azoto | NITROGEN GAS
N2-TOWER Plus
GENERATOR
OPERATING DIAGRAM PRINCIPIO DI FUNZIONAMENTO
The compressed air from an outside source (not L’aria prodotta da un compressore esterno (non
included) is pre-cleaned by passing through a fornito) attraversa un filtro coalescente per
charcoal filter before the Oxygen is removed by the l’essicazione per poi attraversare il sistema PSA a
double column pressure swing adsorption (PSA) doppia colonna per rimuovere l’ossigeno. Mentre
system. One of the PSA columns is active whilst una colonna è operativa la seconda si rigenera per la
the second one fase successiva. L’ossigeno intrappolato viene
is regenerated. The removed gases like Oxygen are scaricato in atmosfera.
released back to the atmosphere.
L’azoto così prodotto viene canalizzato in un
Other trace impurities such as hydrocarbons and serbatoio con catalizzatore (opzionale) in acciaio
CO are removed to levels <0.1ppm whilst the inossidabile così da rimuovere idrocarburi ed il
Nitrogen is passing through an optional catalyst. monossido di carbonio per valori inferiori a 0, 1
An additional filter is installed to remove ppm. Un filtro terminale rimuove eventuali
particulates down to 0.5 microns. particolati maggiori di 0,5 microns
The Nitrogen generators of the N2-TOWER Plus I generatori della serie N2-Tower Plus sono ideali
series are ideal for the method development and per lo sviluppo di analisi GC-HS, ICP, HPLC-
routine analysis by GC, GC-HS, ICP, HPLC- ELSD, TGA-DSC.
ELSD.
Al fine di rimuovere completamente gli
For the complete removal of all hydrocarbons, an idrocarburi presenti un forno catalitico
optional catalytic oven is available. This will opzionale può essere installato così da garantire
guarantee trouble-free operation of FID detectors ottime performance
in GC. in GC-FID
53
PG PLUS DBS
HYDROGEN GENERATOR www.vicidbs.com
DETECTOR GRADE
North America & South America contact: Europe, Asia, Africa, & Australia/Oceania contact:
VICI DBS USA VICI AG INTERNATIONAL
tel: +1 713-263-6970 tel: Int + 41 41 925-6200
fax: +1 713-263-6971 fax: Int + 41 41 925-6201
web: www.vicidbs.com web: www.vicidbs.com
2 | VICI DBS - PG PLUS HYDROGEN GENERATOR
DESCRIPTION
The VICI DBS PG Plus hydrogen generators offer the optimum combination of safe operation, reliability and performance.
®
Designed as a hazard free alternative to high pressure cylinders, all that is required is deionized water and a standard
electrical supply for weeks of continuous operation.
Utilizing the VICI DBS proprietary prepared field proven PEM (Proton Exchange Membrane) incorporated inside a 100%
titanium cell provides superior generator performance and cell life. The unique high pressure permeation membrane
drying system eliminates the requirement for desiccant cartridges along with the associated downtime and cost. Innovative
software control allows unrivaled operational performance and safety as well as the additional options of auto water feed,
remote networking and cascading for built in redundancy.
With a maximum output capacity of 600 mL/min, one generator can supply up to 14 GCs. The compact design allows the
generator to be installed directly in the laboratory eliminating the requirement for long gas lines and guaranteeing the
delivery of high purity gas to your GC.
A sophisticated control system connected to a touch screen continuously monitors vital operating parameters to ensure
safe and consistent performance. Built in sensors will shut the generator down if internal/external leaks are present,
contaminated water, low water or over pressure. This is why the VICI DBS generators meet the strict safety guidelines to be
certified for CE, FCC, MET (UL and CSA compliant).
INCREASE EFFICIENCY IMPROVE SAFETY ENHANCE PERFORMANCE
A constant gas supply with a Gas is produced on demand, Gas generators can be installed
guaranteed purity, eliminates which allows for the safe use of in the laboratory close to the
interruptions of analyses to change the hydrogen generator when instrument, eliminating the need
cylinders and reduces the amount cylinders are prohibited or for long gas lines from external
of instrument re-calibration regarded as potentially dangerous. cylinder supplies. A constant
required. Sophisticated software control and guaranteed high purity gas supply
full alarm capability, including for improves stability and ensures
hydrogen leaks, gives the user full greater reproducibility of results.
control of the gas supply.
VICI DBS - PG PLUS HYDROGEN GENERATOR | 3
FEATURES
Produces a continuous supply of H2 | On-demand supply 24/7 | Flow rate: 100 to 600 mL/min |
Purity: +99.9996% | Pressure: 11 barg (160 psig) | Proprietary 100% titanium cell technology | Unique
permeation membrane drying system | USB connectivity | 2-year complete cell and product warranty |
Easy to install, operate and maintain
BENEFITS
Eliminates dangerous high pressure cylinders helping to keep your employees safer | Removes the
logistics, inconvenience, downtime and costs of a cylinder system | Flow capacity to match your specific
instrument demands | Ideal for all GC detector applications | Meets and exceeds the requirements for
the most demanding GC applications | Superior hydrogen production with reliable long life cell | Minimal
maintenance - no desiccant cartridges to change | PC monitoring for maintenance, diagnostics and remote
connection | Peace of mind | Improve your laboratory work flow and productivity
OPTIONS
I/O board | Remote control software (RS232 or USB) | Cascading hardware (standard or high purity)
| Autorefill
APPLICATIONS
GC APPLICATIONS ANALYZER APPLICATIONS OTHER LAB APPLICATIONS
• GC-FID fuel gas • Total Hydrocarbon • Hydrogenation reactors
• GC-NPD plasma gas Analyzer (THA) fuel gas • Hydrogen fuel cells
• GC-FPD fuel gas
OPERATING DIAGRAM
Hydrogen is produced from the hydrolysis
of deionized water across a PEM (proton
exchange membrane), housed in a 100%
titanium cell. The resultant hydrogen
is dried via a dual stage process, a gas
liquid separator and a unique dual high
performance membrane dryer. In addition
to water all that the generator requires is a
standard connection and supply of electricity
for a continuous 24/7 supply of high purity
hydrogen. Consumable items are limited to
the replacement of a deionizer bag every 6
months.
4 | VICI DBS - PG PLUS HYDROGEN GENERATOR
MODELS & SPECS PG PLUS 100 PG PLUS 160 PG PLUS 250 PG PLUS 300 PG PLUS 500 PG PLUS 600
Flow mL/min 100 160 250 300 500 600
Purity +99.9996%
Dew point at 7 barg (100 psig) -25 oC (-77 oF)
Outlet pressure barg (psig) 0.5 to 11 (7 to 160)
Technology PEM (Proton Exchange Membrane) - 100% Titanium cell
Drying system Regenerative Permeation Membrane
Deionized water quality Minimum < 1 micro S/cm @25ºC - 1 Mohm-cm@25ºC - ASTM II
Recommended < 0.2 microS/cm @25ºC - 5 Mohm-cm @25ºC - ASTM II
Internal water tank (liters) 2.5
Safety Automatic shut down - internal/external hydrogen leak, overpressure and low water
Display Touch screen with operating parameters, system status and safety alarms
LED indicators Power on/off, system ready, errors
Interface USB mod A
Electrical supply 110-120V 60Hz / 220-240V 50Hz
Power consumption (watts) 75 95 140 180 190 230
Dimensions mm (in) 230W x 480H x 370D (9W x 19H x 15D)
Weight kg (lbs) 13 (28.5) 13 (28.5) 13 (28.5) 14 (31) 15 (33) 15 (33)
Shipping dimensions mm (in) 580W x 570H x 400D (22.8W x 22.4H x 15.7D)
Shipping weight kg (lbs) 17 (37.5) 17 (37.5) 17 (37.5) 18 (39.5) 19 (42) 19 (42)
Operating temp oC (oF) 15 to 35 (59 to 95)
Outlet connection 1/8" Compression
Certification CE, FCC, MET (UL and CSA compliant)
OPTIONS
Auto water refill Continuous water feed from an external water supply
Cascading Up to 10 units – built in redundancy for guaranteed up-time
Interface RS232/RS485, external contacts, PC control and intranet
ORDERING INFORMATION (for best service, please call to discuss your application before placing your order).
PG PLUS 100 PG PLUS 160 PG PLUS 250
DB-PHG100-EU 230-240V/50-60Hz DB-PHG160-EU 230-240V/50-60Hz DB-PHG250-EU 230-240V/50-60Hz
DB-PHG100-US 115V/60Hz DB-PHG160-US 115V/60Hz DB-PHG250-US 115V/60Hz
DB-PHG100-JP 100V/60Hz DB-PHG160-JP 100V/60Hz DB-PHG250-JP 100V/60Hz
PG PLUS 300 PG PLUS 500 PG PLUS 600
DB-PHG300-EU 230-240V/50-60Hz DB-PHG500-EU 230-240V/50-60Hz DB-PHG600-EU 230-240V/50-60Hz
DB-PHG300-US 115V/60Hz DB-PHG500-US 115V/60Hz DB-PHG600-US 115V/60Hz
DB-PHG300-JP 100V/60Hz DB-PHG500-JP 100V/60Hz DB-PHG600-JP 100V/60Hz