ENGINEER Project: Design, Supply, Installation, CONTRACTOR :
Testing and Commissioning of Ballastless,
Ballasted Track, Fastening System and
Turnouts in Corridor 2 from Benniganahalli
to Chikkabanavara @ Chainage (-) 1413 to
Chainage 27029 including Ballasted and
Special Tracks in Soladevanahalli Depot.
Format Title: GRADING ANALYSIS
Format No.:RIL-K-Ride-C2-QA-QC-07
As Per IS:2386-Part-1 (CA - 20 mm)
Engineer: Rail Infrastructure Development Company (Karnataka) Limited.
Contractor: RAHEE INFRATECH LIMITED
Location : Frequency: Once in every 7 days
Record No.: Ref. Method.: As per IS 383
Sampling Date : Sample Source :
Testing Date : Sampled By:
Sample Size/ Sample Wt.:- Sample Location:
Cumulative Cumulative %
Weight Cumulative % of Specific Limit As
Sieve Size (mm) Weight of Weight
retained (gm) Weight Retained Per IS 383
Retained Passing
40 mm 100
20 mm 85 - 100
10 mm 0 - 20
4.75 mm 0-5
Pan
Total
Fineness Modulus:
STATUS OF TEST: SATISFACTORY/ UNDER OBSERVATION/ FAILED
RIL Representative GC/K-Ride Representative
Name: …................................................................... Name: …...................................................................
Sign : ….................................................................... Sign : …....................................................................
Date : …................................................................... Date : …...................................................................
ENGINEER: Project: Design, Supply, Installation, CONTRACTOR:
Testing and Commissioning of Ballastless,
Ballasted Track, Fastening System and
Turnouts in Corridor 2 from Benniganahalli
to Chikkabanavara @ Chainage (-) 1413 to
Chainage 27029 including Ballasted and
Special Tracks in Soladevanahalli Depot.
Format Title: GRADING ANALYSIS
Format No.: RIL-K-Ride-C2-QA-QC-06
As Per IS:2386-Part-1 (CA - 10 mm)
Engineer: Rail Infrastructure Development Company (Karnataka) Limited.
Contractor: RAHEE INFRATECH LIMITED
Location : Frequency: Once in every 7 days
Record No.: Ref. Method.: As per IS 383
Sampling Date : Sample Source :
Testing Date : Sampled By:
Sample Size/ Sample Wt.:- Sample Location:
Cumulative Cumulative %
Weight retained Cumulative % of Specific Limit As
Sieve Size (mm) Weight of Weight
(gm) Weight Retained Per IS 383
Retained Passing
12.5 mm 100
10 mm 85 - 100
4.75 mm 0 - 20
2.36 mm 0-5
Pan
Total
Fineness Modulus:
STATUS OF TEST: SATISFACTORY/ UNDER OBSERVATION/ FAILED
RIL Representative GC/K-Ride Representative
Name: …................................................................... Name: …...................................................................
Sign : ….................................................................... Sign : …....................................................................
Date : …................................................................... Date : …...................................................................
ENGINEER: CONTRACTOR
Project: Design, Supply, Installation, Testing and
Commissioning of Ballastless, Ballasted Track,
Fastening System and Turnouts in Corridor 2 from
Benniganahalli to Chikkabanavara @ Chainage (-)
1413 to Chainage 27029 including Ballasted and
Special Tracks in Soladevanahalli Depot.
Format Title: GRADING ANALYSIS
Format No.: RIL-K-Ride-C2-QA-QC-05
As Per IS:2386-Part-1 (Fine Aggregate)
Engineer : Rail Infrastructure Development Company (Karnataka) Limited.
Contractor : RAHEE INFRATECH LIMITED
Location: Frequency: Once in every 7 days.
Record No.: Ref. Method.: As per IS 383
Sampling Date : Sample Source :
Testing Date : Sampled By:
Sample Size/ Sample Wt.:- Sample Location:
Weight retained Cumulative Weight Cumulative % of
Sieve Size (mm) (gm) Retained Cumulative % of Weight Retained Weight Passing Specific Limit As Per IS 383
10 mm 100
4.75 90-100
2.36 75-100
1.18 55-90
0.600 35-59
0.300 8-30
0.150 0-20
Pan
Total
Fineness Modulus:
STATUS OF TEST: SATISFACTORY/ UNDER OBSERVATION/ FAILED
RIL Representative GC/K-Ride Representative
Name: …................................................................... Name: …...................................................................
Sign : ….................................................................... Sign : …....................................................................
Date : …................................................................... Date : …...................................................................