The ZP2-F2-FB-xx is an addressable fire panel designed for small to mid-sized applications, featuring a contemporary design and user-friendly interface with fire brigade controls. It supports up to 256 zones, offers various connectivity options, and complies with multiple safety standards. The panel includes programmable outputs, LED indicators, and a history log, making it versatile for building owners and installers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views2 pages

UTCFire

The ZP2-F2-FB-xx is an addressable fire panel designed for small to mid-sized applications, featuring a contemporary design and user-friendly interface with fire brigade controls. It supports up to 256 zones, offers various connectivity options, and complies with multiple safety standards. The panel includes programmable outputs, LED indicators, and a history log, making it versatile for building owners and installers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product Data Sheet

ZP2-F2-FB-xx
Addressable Fire Panel with User Interface with Fire Brigade controls- 2

Overview

The ZP2 Series life safety control systems are bringing the
speed and functionality of high-end intelligent processing to
small to mid-sized addressable applications. They feature an
attractive contemporary design that fits with any decor. Special
plastics allows for painting in any color and the easy to remove
electronics will support in this matter. The gently lined door with
the intuitive dark inset user interface and EN54 compliant
graphical LCD offers a distinctive flair. The main controls are
clearly, but discreetly highlighted with the focus on the central
located Jog Dial.

With the addressable detection and a full line of easily


configured option cards and modules, USB and Ethernet®
connectivity, these quick-to-configure systems offer versatility
that benefits building owners and life safety system installers Standard Features
alike.
E 2 loops expandable to 4 with up to 256 zones with Fire
Brigade & Fire Protection controls and 300 output groups
The Panel E Up to 40 LED Zone indicators for Fire and Fault with ample
text space
The fire panels supplied in local language, with user interface E Auto configuration and default EN54 setup modes
with fire brigade and fire protection controls, with 2 loops that E Ethernet port with TCP/IP for remote maintenance and
supports up to 254 devices each (127 addresses) in 128 zones, programming
have standard 4 supervised sounder/fire-routing outputs, which E EN54 compliant graphical LCD with icons and symbols for
can be used as freely programmable outputs as well. In addition easy recognition of events
2 conventional relay outputs and 2 supervised outputs, working E Jog Dial with 4 soft buttons for simple and intuitive user
in pair and dedicated to common fire and fault conditions, as control
well as 2 user configurable inputs for monitoring and control are E Aesthetic pleasing design with special paintable synthetic
available. door
E Easy removable door and chassis for quick and clean
installation
Options E All pluggable connectors
E 3 USB ports with memory stick support and RS232 for
The panels supports an extra 2 loop board that brings the panel printer support
to up to 256 zones with 4 additional programmable outputs, one E Email notification for events directly from the panel (4 user
auxiliary relay board with 8 outputs - 2 standard fitted with accounts)
relays and 6 open collector outputs with the option to add relays E Auxiliary 24VDC supply output with reset support
afterwards - and one network board to create a maximum of 32 E 3 operator level menu structure (20 user names and
nodes / 32 loops network of fire panels, fire panel repeaters and passwords)
black-boxes (including conventional fire panels and fire panel E History log memory for 9999 events
repeaters up to a maximum of 64 conventional zones). Last but E Up to 72 hours standby time and 30 minutes alarm
not least, in case seperate zone indications are required, a 20 E Compatible with the Ziton loop powered sounders/beacons
or a 40 zone fire/fault LED indicator board can be mounted in and base sounders and Ziton series detectors
the panel or repeater with ample space for custom text.

Approvals & Compliance

• CE / CPD / EN54-2 / EN54-4


• NEN2535 / NBNS21-100 compliant
• BS5839-1 compliant
• VdS and LPCB certified
• WEEE / RoHS compliant
ZP2-F2-FB-xx
Addressable Fire Panel with User Interface with Fire Brigade controls- 2

Specifications Ordering Information


Mains supply Part No. Description
Voltage 230 / 110 VAC (+10% / -15%) ZP2-F2-FB-xx Addressable Fire Panel with User Interface with Fire Brigade
Frequency 50 / 60 Hz (±5%) controls- 2 Loop
Current Nom. 0.6 / 1.3 A, Max. 1.5 / 3.15 A -xx Language Codes
Fuse rating 2/4A
Cable type 3 x 1.5 mm² (live, neutral, earth) ZP2-ZI-20 Addressable Fire Panel Component - LED indicator - 20 zone
Batteries Max. 2 x 12V/18Ah (use supplied cables)
ZP2-ZI-40 Addressable Fire Panel Component - LED indicator - 40 zone
Outputs
Programmable supervised 4, 750mA / 19.5-28VDC (24VDC nominal) ZP2-LB Addressable Fire Panel Accessory - Loop Expansion Printed
General Fire + Fault Circuit Board - 2 loop
2, 350mA / 19.5-28VDC (24 VDC nominal)
supervised
BS127N Sealed Lead-Acid Battery - 12V 7.2Ah
General Fire + Fault relay 2
1 resetable, 500mA / 19.5-28VDC (24VDC BS130N Sealed Lead-Acid Battery - 12V 12Ah
Aux nominal)
Cable type Recommended 2 core 1.5 mm² twisted pair BS131N Sealed Lead-Acid Battery - 12V 18Ah
End of Line resistor 15kohm
Inputs 2010-2-FTP-C30 Addressable Fire Panel Accessory - Cable FTP CAT5 - 3m
Programmable 2
2010-2-USB-C30 Addressable Fire Panel Accessory - Cable USB A to B - 3m
Cable type Recommended 2 core 1.5 mm² twisted pair
End of Line resistor 15kohm
Maximum Load 150 mA
Loops
Outputs 2, 300mA@11VDC (peak 500mA@20V)
max 52ohms / 500nF (max 2km with 2mm² and
Cable length 127 detectors)
Cable type Recommended 2 core 1.5 mm² twisted pair
Environmental conditions
Storage temperature -10°C to +50 °C
Operating temperature -5°C to +40 °C
Relative humidity max. 95 % (non-condencing)
Mechanical
Size (W x D x H) 449.6 x 171.2 x 550 mm
Weight 7.4 kg (without batteries)
Color RAL7035
Cable entries (Top / Bottom 18 (20mm) / 2 (20mm) / 2 removable plates
/ Back)
IP rating IP30: for indoor use only

As a company of innovation, UTC Fire & Security reserves the right to change product
specifications without notice. For the latest product specifications, visit UTC Fire & Security
online or contact your sales representative.
ZP2-F2-FB-xx-2016-10-19 19:15:30 Released :08-FEB-13

You might also like