0% found this document useful (0 votes)
10 views3 pages

Lcb3a Prices en

The LCB3A is a hygienic universal digitizer for load cells that converts analog signals into digital format and is designed for IoT applications. It features a micro USB port for PC configuration, multiple communication interfaces, and is compliant with various international standards. The device supports up to four load cells and includes advanced functions for precision batching and calibration.

Uploaded by

phat nguyen minh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views3 pages

Lcb3a Prices en

The LCB3A is a hygienic universal digitizer for load cells that converts analog signals into digital format and is designed for IoT applications. It features a micro USB port for PC configuration, multiple communication interfaces, and is compliant with various international standards. The device supports up to four load cells and includes advanced functions for precision batching and calibration.

Uploaded by

phat nguyen minh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

LCB3A

HYGIENIC UNIVERSAL DIGITIZER FOR LOAD CELLS

COMING SOON

MICRO USB FOR


PC CONFIGURATION

DESCRIPTION

 LCB3A transforms an analog load cell (mV/V output) into a digital one; it can also be used on existing load cells to digitize the weighing
system.
 Hygienic device RPSCQC authorized by 3-A SSI.
 Conceived for IoT applications (Internet of Things).
 PC configuration software via micro USB port.
 Status LED of the communication interface.
 Mounting: wired or integral to the load cell body via standard ¼ GAS fitting (specific adapters for different threads are supplied on request).
 IP67 AISI 304 stainless steel box (dimensions: 90x40x107 mm including flying connectors).
 3 M12 hygienic connectors with solder terminals included in the supply.
 The instrument can be configured and managed using the free “Instrument Manager” PC software, which you can download from www.
laumas.com.

INPUTS/OUTPUTS AND COMMUNICATION

 1 micro USB port.


 3 relay outputs controlled by the setpoint values or via protocols.
 2 digital inputs: status reading via serial communication protocols.
 1 load cell input.

CERTIFICATIONS

Complies with the Eurasian Custom Union regulations

Equivalent of the CE marking for the United Kingdom

American standard that regulates the design, production and use of hygienic equipment

FIELDBUSES
R ev. 0 .0

LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com
LCB3A
HYGIENIC UNIVERSAL DIGITIZER FOR LOAD CELLS

INTERFACES AND FIELDBUSES

EURO

RS485.
Male M12 circular connector, A-coded, 5-pin.
coming soon
Female M12 circular connector, A-coded, 5-pin.
Baud rate: 2400, 4800, 9600, 19200, 38400, 115200 (bit/s).

RS485 + analog output.


Current: 0÷20 mA; 4÷20 mA (up to 400 Ω).
Voltage: 0÷10 V; 0÷5 V (min 2 kΩ). 628,00
Male M12 circular connector, A-coded, 5-pin.
Female M12 circular connector, A-coded, 5-pin.

IO-Link.
2x male M12 circular connector, A-coded, 4-pin. 628,00
The instrument works as device in a IO-Link network.

CANopen.
Male M12 circular connector, A-coded, 5-pin.
Female M12 circular connector, A-coded, 5-pin.
661,00
The instrument works as slave in a CANopen synchronous network.

CC-Link IE Field Basic.


2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as slave in a CC-Link IE Field Basic network.

CC-Link.
Male M12 circular connector, A-coded, 4-pin. coming soon
Female M12 circular connector, A-coded, 5-pin.
The instrument works as Remote Device Station in a CC-Link network and occupies 3 stations.

Profibus DP.
Male M12 circular connector, B-coded, 5-pin.
coming soon
Female M12 circular connector, B-coded, 5-pin.
The instrument works as slave in a Profibus DP network.

Modbus/TCP.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as slave in a Modbus/TCP network.

Ethernet TCP/IP.
Female M12 circular connector, D-coded, 4-pin. coming soon
The instrument works in an Ethernet TCP/IP network and it is accessible via web browser.

Ethernet/IP.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as adapter in an Ethernet/IP network.

Profinet IO.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as device in a Profinet IO network.

EtherCAT.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as slave in an EtherCAT network.

POWERLINK.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as slave in a Powerlink network.

SERCOS III.
2x female M12 circular connectors, D-coded, 4-pin. 705,00
The instrument works as slave in a Sercos III network.
R ev. 0 .0

LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com
LCB3A
HYGIENIC UNIVERSAL DIGITIZER FOR LOAD CELLS

MAIN FUNCTIONS

 Connections to: BASE PROGRAM


- PLC via analog output or fieldbuses;  Hysteresis and setpoint value setting.
- PC/PLC via RS485 (up to 99 instruments with line repeaters, up
to 32 without line repeaters); SINGLE PRODUCT LOADING PROGRAM
- up to 4 load cells in parallel by junction box.  99 settable formulas.
 TCP/IP WEB APP: integrated software in combination with the  Automatic fall calculation.
Ethernet TCP/IP version for remote supervision, management and
control of the instrument.
 Tolerance error control.
 Precision batching through slow function.
 Digital filter to reduce the effects of weight oscillation.  Precision batching through tapping function.
 Theoretical calibration (via PC software) and real calibration (with  Consumption storage.
sample weights and the possibility of weight linearization up to 8
points).  Batching start via external contact or fieldbus.
 Calibration via characterization values of the load cell.
 Tare weight zero setting.
 Automatic zero setting at power-on.
 Gross weight zero tracking.
 Semi-automatic tare (net/gross weight) and preset tare.
 Semi-automatic zero.
 Direct connection between RS485 and RS232 without converter.
 Configuration backup and restore via PC software.

TECHNICAL FEATURES

Power supply and consumption 12÷24 VDC ±10%; 5 W


Number of load cells • Load cells supply up to 4 (350 Ω) - 4/6 wires • 3.3 VDC/40 mA
Linearity • Analog output linearity <0.01% full scale • <0.01% full scale
Thermal drift • Analog output thermal drift <0.0005% full scale/°C • <0.003% full scale/°C
A/D Converter 24 bit (16000000 points) - 4.8 kHz
Divisions (with measurement range ±10 mV and sensitivity 2 mV/V) ±999999 • 6.6 nV/d
Measurement range ±26 mV
Usable load cells sensitivity ±7 mV/V
Conversions per second 500/s
Decimals • Display increments 0÷4 • x1 x2 x5 x10 x20 x50 x100
Digital filter • Readings per second 3 filter types • 5÷500 Hz
Relay outputs 3 - max 115 VAC/150 mA - 24 VDC/200 mA
Digital inputs 2 - 5÷24 VDC
Micro USB port B type - USB 2.0 (full-speed)
Humidity (condensate free) 85%
Storage temperature -30 °C +80 °C
Working temperature -20 °C +50 °C
R ev. 0 .0

The Company reser ves the right to make changes to the technical data, drawings and images without notice.

LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001