Profile - Renovate Cooling Tower 2
Profile - Renovate Cooling Tower 2
Our Cooling Tower products are widely used in electrical power Plant, chemical industrial,
metallurgy, light industrial, civil facilities and other fields. We also have excellent after-sales service
team.
Establishment
Renovate cooling tower Is establishment in Bangladesh.Since 2015 to continue.We improves day by day
and use latest technology to Improves Our Products Quality by experienced and professional
entreneurs.Who are committed to produce a quality range of products.
OUR CORE
Our core competencies are the reasonable price with superior quality and also our products own high
efficiency, environmental protection, easy installation, operation and maintenance , long service life
and what matters most is that we pay more attention to customer’s feelings.
01
OUR PRODUCTS LIST
02
Evaporative Cooling Tower
SPECIFICATIONS ALL KINDS OF COOLING TOWER
Parts Details
Counter Flow Bottle Type Cooling Tower Counter Flow Square Type Cooling Tower
Bearing Housing
Motor
Ladder
Fan Guard
Fan
Motor Support
Sprinkler System/Nozzle
Casing
Infill Support
Infill
Sump
Suction Tank
Float Valve Assembly
Air Inlet Louver
Ladder
Access Door
Range
Water Outlet
re
tu
ra
2
pe
m
Suction Tank
te
3
lb
bu
30 9
4
-
2 8
et
2 6
5
2 5
en
2 4
2 3
bi
2 2
1
Am
Water Inlet
2 1
6
2 0
2
7
Infill
8
Lower Frame
12 1
1
13
14
15
16
Remarks
1 For cooling tower hot water temperature exceeding 500 C, heat-resistant version should be used (delivered by special order).
2 If suitable model cannot be found from the chart, please inquire us.
04
CLASSIFICATION OF COOLING TOWER
Mechanical Draft
Forced Draft Induced Draft Induced Draft Forced Draft Induced Fraft Splash Type Splash Type
Counter Flow Counter Flow Bottle Type Counter Flow Square Type Cross Flow Cross Flow Counter Flow Cross Flow
Cooling Tower Cooling Tower Cooling Tower Cooling Tower Cooling Tower Cooling Tower Cooling Tower
Difference Between Counter Flow, Cross Flow And Natural Draft Cooling Tower
Fan EXCHANGE
Hot Water in SURFACE
Air Air AIR AIR
in Fill Fill in
Fill Media
Air in Air in
Cold water BASIN COOLED
Cold Water Out out WATER
Hot water
exits at top. inlet
Hot water
Uses forced and induced Advantages: Suited for
Fill
draft fans. high air resistance & fans
Fill Advantage:les recirculation are relatively quiet
Cold water Centrifugal
than forced draft towers. fan Disadvantages:
Disadvantage: fans and recirculation due to high
Cold water motor drive mechanism air-entry and low air-exit
require weather-proofing. Cold water velocities
05
Evaporative Cooling Tower
SPECIFICATIONS OF COUNTER FLOW BOTTLE TYPE COOLING TOWER
Design Condition
Water flow rate=390m3/h
Tin=370C
H
H
Tout=320C
WBT=290 C
Dº Dº
Dº IRT=3900 Kcal/hour
RRT-10~40 RRT-50~300 RRT-350~500
B A B
H1 H1
H1 H1
H1 B B
Details
B
4
120 H2 B H2 B
ZT
B W W W
W
Z
C H1 C
Dia Dia C 10
C
B Dia Dia
Dia
45
20 20
Z Z
In RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT RRT
mm 10 20 30 40 50 60 80 100 125 150 175 200 225 250 300 350 400 500 600
W 580 811 925 925 931 931 1135 1360 1360 2260 1400 1400 1255 1255 1255 1760 1760 2680 2680
B 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300
C 300 300 300 300 400 400 400 580 580 580 3725 3725 3725 600 600 600 600
H 300 300 400 400 400 400 300 300 300 300 300 300 300 300 300 300 300 300 300
Dia 670 937 1308 1308 1317 1317 1605 1923 1923 2336 2799 2799 3280 3280 3280 4600 4600 5359 5359
07
Evaporative Cooling Tower
SPECIFICATIONS OF COUNTER FLOW SQUARE TYPE COOLING TOWER
Design Condition
Water flow rate =390m3/h
H Tin=370 C
Tout=320 C
WBT=290 C
IRT= 3900 kcal/hour
Specification of Piping Connection : For high tempreture condition, the pipe diameter might be changed please consult with
our representaive
RRTS 40 50 60 80 100 125 150 175 200 225 250 300 350 400 500 600 700 800
Inlet 80 80 80 100 125 125 150 150 150 200 200 200 200 200 250 250 250 300
Outlet 80 80 100 125 125 150 150 150 200 200 200 200 200 250 250 250 300
Overflow 25 25 25 40 40 40 40 50 80 80 80 100 100 100 100
Drain 25 25 40 40 40 40 40 40 40 40 40 40 80 80 80 80
Float valve 15 20 20 20 20 20 20 25 25 25 25 50 50 50 50
Makeup - - - - 20 20 20 20 25 25 25 25 25 50 50 50 50
Foundation Details : For multiple cells configuration, consult for tower layout & foundation dimension.
IT
EM Foundation Dimension (mm) Anchor Bold
M
O
D
Lenght QTY
C E A B C1 C2 D H Size
L mm Pcs
C2 RRTS-40 1500 1500 N/A 750 200 300 M16 150 4
RRTS-50 1500 1500 N/A 750 200 300 M16 150 4
RRTS-60 1750 1750 N/A 875 200 300 M16 150 4
C
RRTS-70 1750 1750 N/A 875 200 300 M16 150 4
RRTS-80 2000 2000 N/A 1000 200 300 M16 150 4
RRTS-100 2000 2000 N/A 1000 200 300 M16 150 4
B
C RRTS-125 2200 2300 N/A 1100 200 300 M16 150 4
RRTS-150 2300 2300 N/A 1150 200 300 M16 150 4
RRTS-175 2700 2700 1350 1350 250 500 M16 150 4
RRTS-200 2700 2700 1350 1350 250 500 M16 150 4
C RRTS-225 3000 3000 1500 1500 250 500 M16 150 4
RRTS-250 3300 3300 1500 1650 250 500 M16 150 9
RRTS-300 3500 3500 1650 1650 250 500 M16 150 9
RRTS-350 3700 3700 1750 1750 250 500 M16 150 9
A RRTS-400 4200 4200 1850 1850 250 500 M16 150 9
RRTS-500 4600 4600 2100 2100 300 500 M16 150 9
D
H RRTS-600 4900 4900 1533 1533 300 500 M16 150 16
RRTS-700 5350 5350 1783 1783 300 500 M16 150 16
RRTS-800 5650 5650 1883 1883 300 500 M16 150 16
Renovate Cooling Tower the specification subject right to change without further notice. Please consult with our respresentative
09
Evaporative Cooling Tower
SPECIFICATIONS OF CROSS FLOW COOLING TOWER
H2
A
Design Condition
25
Water flow rate =390m3/h
Tin=370 C
Tout=320 C
H3
H1
WBT=290 C
W
IRT= 3900 kcal/hour
400
1400
660
D E
200 B F
310
210
95
L
400 200
100 300
L/MIN FAN MOTER FAN DEAD OPPERATING IN OUT OVER AUTO QUICK
RRTX L W H1 H2 H3 DRIVE KG DRAIN
CM3/H HP SPEED KG LET LET D E F
1300
RRTX-100 2HP 4P 512 V-BELT 140X2 125 50A 50A 25A 25A
78 1500 3560 2075 815 3550 1300X DIRECT 970 1950
4HP 8P 750 DRIVE 5 5 2 2 1 1
1625 3HP 4P 625 V-BELT 140X2 125 50A 50A 25A 25A
RRTX-125 1500 3560 2075 815 3550 1300X1 DIRECT 990 1970
98 3HP 6P 750 DRIVE 5 5 2 2 1 1
1950 5HP 4P 465 V-BELT 165 50A 50A 25A 25A
RRTX-150 1800 3760 2075 915 3550 1500X1 DIRECT 1110 2360 140X2
117 3HP 8P 750 DRIVE 6 2 2 1 1
2275 7.5HP 4P 557 V-BELT 165 50A 50A 25A
RRTX-175 1800 3760 2075 915 3550 1500X1 DIRECT 1200 2460 140X2 25A
137 5HP 8P 750 DRIVE 6 2 2 1
2600 7.5HP 4P 495 V-BELT 165 65A 65A 25AX2 40A
RRTX-200 2100 3960 2075 915 3680 1700X1 DIRECT 1400 2840 140X2
156 5HP 10P 560 DRIVE 6 2.5 2.5 X2 1.5
3250 7.5HP 4P 450 V-BELT 200 65A 65A 25AX2 40A
RRTX-250 2450 4260 2075 915 3720 2000X1 DIRECT 1600 3510 140X2
195 5HP 10P 560 DRIVE 8 2.5 1X2 1.5
3900 10HP 4P 475 V-BELT 200 80A 80A 25AX2 40A
RRTX-300 2450 4565 2075 1200 3935 2000X1 DIRECT 1800 3700 165X2
234 7.5HP 12P 480 DRIVE 8 3 3 1 1.5
5460 10 HP 4P 475 V-BELT 200 80A 80A 25AX2 40A
RRTX-350 3150 5080 2075 1200 3935 2400X1 DIRECT 2000 4300 165X2
273 7.5HP12P 480 DRIVE 8 3 3 1X2 1.5
5220 15 HP V-BELT 250 80A 80A 25X2 50A
RRTX-400 3150 5630 2800 1200 4800 2400 475 OR 2800 5800 165X2
312 4P GEAR 10 3 3 1X2 2
6500 15 HP 380 V-BELT 250 80A 80A 25X2 50A
RRTX-500 3700 6000 2800 1200 4800 3000 OR 3500 7506 165X2
390 4P GEAR 10 3 3 1X2 2
7800 20 HP 340 V-BELT 250 80A 80 25X2 50A
RRTX-600 4000 6650 2800 1200 4800 3200 OR 4250 8100 165X2
468 4P GEAR 10 3 A 1X2 2
9160 20 HP 340 V-BELT 250 80A 80A 25X2 50A
RRTX-700 4000 6650 3200 1200 5300 3200 OR 4800 9000 200X2
546 GEAR 10 3 3 2
10400 25 HP 340 V-BELT 300 100A 100A 25AX2 65A
RRTX-800 4000 6650 3400 1200 5700 3200 OR 5200 11250 200X2
625 GEAR 12 4 4 1X2 2.5
13000 30 HP 320 V-BELT 300 100A 100A 25XAX2 65A
RRTX-1000 4600 7000 4300 1200 5800 3600 OR 7600 15200 200X2
780 GEAR 12 4 4 1X2 2.5
D
MODEL A B C D E F
Anchr hole 100 x 200 depth
B
(onchor bolt m 16 x 200) RRTX 100-125 1300 1115 1240 1600 3560
Junction iron bar
4700 1250
-
A
400 150 1000 4400 1375 4000 4700 1250 7050
11
Evaporative Cooling Tower
SPLASH TYPE COOLING TOWER
Design Condition
Water flow rate =390m3/h
H Tin=370 C
Tout=320 C
WBT=290 C
IRT= 3900 kcal/hour
Specification of Piping Connection : For high tempreture condition, the pipe diameter might be changed please consult with
our representaive
RRTS 40 50 60 80 100 125 150 175 200 225 250 300 350 400 500 600 700 800
Inlet 80 80 80 100 125 125 150 150 150 200 200 200 200 200 250 250 250 300
Outlet 80 80 100 125 125 150 150 150 200 200 200 200 200 250 250 250 300
Overflow 25 25 25 40 40 40 40 50 80 80 80 100 100 100 100
Drain 25 25 40 40 40 40 40 40 40 40 40 40 80 80 80 80
Float valve 15 20 20 20 20 20 20 25 25 25 25 50 50 50 50
Makeup - - - - 20 20 20 20 25 25 25 25 25 50 50 50 50
Foundation Details : For multiple cells configuration, consult for tower layout & foundation dimension.
IT
EM Foundation Dimension (mm) Anchor Bold
M
O
D
Lenght QTY
C E A B C1 C2 D H Size
L mm Pcs
C2 RRTS-40 1500 1500 N/A 750 200 300 M16 150 4
RRTS-50 1500 1500 N/A 750 200 300 M16 150 4
RRTS-60 1750 1750 N/A 875 200 300 M16 150 4
C
RRTS-70 1750 1750 N/A 875 200 300 M16 150 4
RRTS-80 2000 2000 N/A 1000 200 300 M16 150 4
RRTS-100 2000 2000 N/A 1000 200 300 M16 150 4
B
C RRTS-125 2200 2300 N/A 1100 200 300 M16 150 4
RRTS-150 2300 2300 N/A 1150 200 300 M16 150 4
RRTS-175 2700 2700 1350 1350 250 500 M16 150 4
RRTS-200 2700 2700 1350 1350 250 500 M16 150 4
C RRTS-225 3000 3000 1500 1500 250 500 M16 150 4
RRTS-250 3300 3300 1500 1650 250 500 M16 150 9
RRTS-300 3500 3500 1650 1650 250 500 M16 150 9
RRTS-350 3700 3700 1750 1750 250 500 M16 150 9
A RRTS-400 4200 4200 1850 1850 250 500 M16 150 9
RRTS-500 4600 4600 2100 2100 300 500 M16 150 9
D
H RRTS-600 4900 4900 1533 1533 300 500 M16 150 16
RRTS-700 5350 5350 1783 1783 300 500 M16 150 16
RRTS-800 5650 5650 1883 1883 300 500 M16 150 16
Renovate Cooling Tower the specification subject right to change without further notice. Please consult with our respresentative
13
TECHNICAL SPECIFICATIONS OF CROSS FLOW SPLASH TYPE (ETP) COOLING TOWER
4”
W
TOP OF
PERIMETER
GUARDRAIL
Design Condition
Water flow rate =390m3/h
Tin=370 C
Tout=320 C
H WBT=290 C
BASE OF IRT= 3900 kcal/hour
PERIMETER
L TOWER COLUMNS
TOP OF
SUPPORTING
STEEL
61/4”
ENDWALL ELEVATION
4” PLAN
L/MIN FAN MOTER FAN DEAD OPPERATING IN OUT OVER AUTO QUICK
RRTX L W H1 H2 H3 DRIVE KG DRAIN
CM3/H HP SPEED KG LET LET D E F
1300
RRTX-100 2HP 4P 512 V-BELT 140X2 125 50A 50A 25A 25A
78 1500 3560 2075 815 3550 1300X DIRECT 970 1950
4HP 8P 750 DRIVE 5 5 2 2 1 1
1625 3HP 4P 625 V-BELT 140X2 125 50A 50A 25A 25A
RRTX-125 1500 3560 2075 815 3550 1300X1 DIRECT 990 1970
98 3HP 6P 750 DRIVE 5 5 2 2 1 1
1950 5HP 4P 465 V-BELT 165 50A 50A 25A 25A
RRTX-150 1800 3760 2075 915 3550 1500X1 DIRECT 1110 2360 140X2
117 3HP 8P 750 DRIVE 6 2 2 1 1
2275 7.5HP 4P 557 V-BELT 165 50A 50A 25A
RRTX-175 1800 3760 2075 915 3550 1500X1 DIRECT 1200 2460 140X2 25A
137 5HP 8P 750 DRIVE 6 2 2 1
2600 7.5HP 4P 495 V-BELT 165 65A 65A 25AX2 40A
RRTX-200 2100 3960 2075 915 3680 1700X1 DIRECT 1400 2840 140X2
156 5HP 10P 560 DRIVE 6 2.5 2.5 X2 1.5
3250 7.5HP 4P 450 V-BELT 200 65A 65A 25AX2 40A
RRTX-250 2450 4260 2075 915 3720 2000X1 DIRECT 1600 3510 140X2
195 5HP 10P 560 DRIVE 8 2.5 1X2 1.5
3900 10HP 4P 475 V-BELT 200 80A 80A 25AX2 40A
RRTX-300 2450 4565 2075 1200 3935 2000X1 DIRECT 1800 3700 165X2
234 7.5HP 12P 480 DRIVE 8 3 3 1 1.5
5460 10 HP 4P 475 V-BELT 200 80A 80A 25AX2 40A
RRTX-350 3150 5080 2075 1200 3935 2400X1 DIRECT 2000 4300 165X2
273 7.5HP12P 480 DRIVE 8 3 3 1X2 1.5
5220 15 HP V-BELT 250 80A 80A 25X2 50A
RRTX-400 3150 5630 2800 1200 4800 2400 475 OR 2800 5800 165X2
312 4P GEAR 10 3 3 1X2 2
6500 15 HP 380 V-BELT 250 80A 80A 25X2 50A
RRTX-500 3700 6000 2800 1200 4800 3000 OR 3500 7506 165X2
390 4P GEAR 10 3 3 1X2 2
7800 20 HP 340 V-BELT 250 80A 80 25X2 50A
RRTX-600 4000 6650 2800 1200 4800 3200 OR 4250 8100 165X2
468 4P GEAR 10 3 A 1X2 2
9160 20 HP 340 V-BELT 250 80A 80A 25X2 50A
RRTX-700 4000 6650 3200 1200 5300 3200 OR 4800 9000 200X2
546 GEAR 10 3 3 2
10400 25 HP 340 V-BELT 300 100A 100A 25AX2 65A
RRTX-800 4000 6650 3400 1200 5700 3200 OR 5200 11250 200X2
625 GEAR 12 4 4 1X2 2.5
13000 30 HP 320 V-BELT 300 100A 100A 25XAX2 65A
RRTX-1000 4600 7000 4300 1200 5800 3600 OR 7600 15200 200X2
780 GEAR 12 4 4 1X2 2.5
D
MODEL A B C D E F
Anchr hole 100 x 200 depth
B
(onchor bolt m 16 x 200) RRTX 100-125 1300 1115 1240 1600 3560
Junction iron bar
4700 1250
-
A
400 150 1000 4400 1375 4000 4700 1250 7050
14
SPARE PARTS OF COOLING TOWER
Counter Flow Cooling Tower Infill Cross Flow Cooling Tower Infill
Material-PVC Material-PVC
Honey Comb structure Honey Comb structure
Sheet to sheet bonding by PVC Sheet to sheet bonding by PVC
Solution Solution
Rectangular or circular shape Rectangular or circular shape
Black/green/transparent color Black/green/transparent color
Vacuum forming Vacuum forming
Nozzle : PPA.
Turbulator : ABS
Adapter : ABS
SS Extended Shaft
Aluminum/PVC metal net. Low RPM 950-550.
Washable. IP-55, insl, class F. S1 duty
Small mesh size. TEAC/TEFC
Water proof
Low RPM.
S.S.Shaft
Worm Bevel Gear.
Teper Bearing
Lubricated By Gear Oil.
Oil System
Permanent Lube Bearing.
Galvanised Structure.
Easy Mainteance.
15
INDUSTRIRAL BLOWER (EXHAUST FAN)
Our energy saving industriral Blower (Exhaust Fan) is easy to install. These exhaust fan have
automatic shutter on one side and a security grill on other side to prevent accidents. they
consume low power but have high capacity and create less noise.
1380mm
1220mm
1100mm
1000mm
900mm
820mm
720mm
1380mm
600mm
1100mm
1220mm
1000mm
900mm
820mm
720mm
600mm
QCHS1250 (54” Fan) QCHS1110 (48” Fan) QCHS1000 (44” Fan) QCHS900 (40” Fan) QCHS760 (36” Fan) QCHS750 (32” Fan)
QCHS610 (28.5” Fan) QCHS550 (24” Fan)
BODY SIZE
BlADE
BODY BLADE SHUTTER CAPACITY
ROUND MOTOR
NOISE
FAN
MODEL
(MM)
ROTATING
MATERIAL MATERIAL MATERIAL (m3/Hr.)
SPEED SPEED
(db)
POWER WEIGHT
DIA (Inc) (RPM) (RPM) (kg)
QCHS1250 Stainless Steel Stainless Steel 1.1/1.5Kw, 3PH
(54” Fan) 1380X1380X400 50” Galvanized Steel Alumunium Alloy Alumunium Alloy 44000 439 1400 =70
Galvanized Steel Galvanized Steel 380Volt. 50Hz 85
16
ROOF MOUNTED NEGATIVE PRESSURE SYSTEM :
In case a wall mounted negative pressure ventilation system is not applicable, then roof mounted
system is specially designed for roof mounted application.
KF 48
KF 54-2P KF 36
KF 60-3A
LR 54-3A
BODY SIZE BLADE BODY BLADE NO. OF ROUND SPEED POWER CAPACITY
MODEL FAN WEIGHT
(CM) (INC) MATERIAL MATERIAL BLADE (RPM) (Hp) (M³/Hr.)
SMC OR 2 85 45,000
KF - 48 239.6X160 (94.70) 48” FRP 3 630
ALUMINIUM
17
AXIAL BLOWER FAN
Dimensions
Zx D
Di
Da
K E
L Tk
AXC Di Da Tk Zx D L hf E K
AXCP 315 315 395 355 8x10 425 235 265 360
AXCP 355 355 435 395 8x10 425 250 305 360
AXCP 400 400 480 450 8x12 450 280 350 385
AXCP 450 450 530 500 8x12 500 315 400 435
AXCP 500 500 590 560 12x12 554 335 440 464
AXCP 560 560 650 620 12x12 500/750 * 375 500 424/674 *
AXCP 630 630 720 690 12x12 500/750 * 425 570 424/674 *
AXC 710 710 800 770 16x12 500/700/800 * 450 650 424/624/722 *
AXC 800 800 890 860 16x12 500/700 * 530 730 414/614 *
AXC 900 900 1005 970 16x15 640/850 * 560 830 552/762 *
AXC 1000 1000 1105 1070 16x15 640/850 * 670 930 552/762 *
AXC 1200 1120 1260 1190 20x15 700/1000 * 710 1030 612/910 *
AXC 1250 1250 1390 1320 20x15 850/1050 * 800 1180 740/938 *
Dimensions in mm.
* Dimensions L + K depend on motor frame size
Ordering code
AXC 630 - 9 / 22 - 2 - EK
Economy with terminal box
2-pole motor
Pitch angle
Number of blades
Nominal diameter
18
PUMPS AND PUMPING SYSTEMS
Base Mounted End Suction Pump Submersible Pump
Duty Parameter : Duty Parameter :
3 3
Capacity: Up to 600m /hr Capacity: Up to 2500m /hr
Head: Up to 150m Head: Up to 580m
0
Temp: up to 120 C 0
Temp: up to 40 C
Delivery Size: DN 32-DN150 Delivery Size: DN 252-DN 400
Applications : Applications :
General industry Water supply from borehole
Chemical & process Sprilking and Irrigation
Water supply Pressure Boosting
Building service/fire fighting Process Water supply
Irrigation/sprinkler system
Applications :
HVAC Systems Applications :
Water Transfer Building service
Distribution Systems Hot water
Fire Fighting Water glycol mixture
Cooling Tower Cold water without abrasive
Substances
Applications : Applications :
Pressure Boosting for Waste water transfer
residential building Sewage treatment plants
Small cottages and Effluent treatment plants
bungalow Dirty water in industry
PFI Panel
VCB
LT SWITCHGEAR
AVR
19
ETP, WTP & STP ALL KINDS OF SPARES CHEMICALS & CONSULTANCY
The safe water demand & environmental pollution are increasing in Bangladesh. We Renovate Cooling
Tower offer superior total water management solution to hold the trade & business to stay green as well
as competitive Through deep extended expertise and best engineering practices. If we are of obsessed
with the quality of our products & services and our customer, growth & profit are brown to follow.
Applications : Applications :
Waste Water Supply ETP, STP and Aquaculture
Sewage treatment plants Electroplating Industry
Effluent treatment plants Paper, Chemical and Food Industry
Dirty water in industry
Applications : Applications :
ETP, STP and Aquaculture Industrial & Municipal wastewater
Electroplating Industry treatment
Paper, Chemical and Food Aeration of fish pond
Industry Aeration of streams and lakes
Sludge stabilization
20
ETP, WTP & STP ALL KINDS OF SPARES CHEMICALS & CONSULTANCY
Tube Diffuser Saddle
Duty Parameter : Duty Parameter :
Support Disk: PVC Suitable for 2” to 5” air pipe
Length: up to 1000 Inch
Connection : 3 4 PT
Operation Temp: up to 1000C Applications :
Industrial & Municipal
Applications : wastewater treatment
Aeration of fish pond
Industrial & Municipal
Aeration of streams and lakes
wastewater Treatment
Aeration of fish pond
Aeration of streams and lakes
sludge stabilization
Applications :
Wastewater lift station, municipal wastewater
treatment plant.
Building wastewater treatment system.
Piggery excrement, animal & poultry farm.
wastewater treatment system.
Applications :
Waste water, civil discharfes
Industries, farms, paper-mills, tanneries
Dish industries and soon.
21
ETP, WTP & STP ALL KINDS OF SPARES CHEMICALS & CONSULTANCY
pH Controller
Duty Parameter :
Measuring Varable : pH
Measuring Range : pH 0.00-14.0
Tube Pack
Applications :
Water Treatment Plant
Waste Water Treatment Plant
22
WATER TREATMENT CHEMICALS
Cooling Tower Water Treatment Chemicals
Discalant Antiscalant
Function : Cleans the equipment as per the Function : It works as an Antiscalant and
requirement Corrosion inhibitor
Capacity Available : 35 Kg Capacity Available : 35 Kg
23
HEAT EXCHANGER
Plate Heat Exchangers
INTRODUCTION:
High Performance Heat Transfer Plates. Fast Installation, Easy Maintenance. Posibility Of Adding Extra
Plates to Incase Capacity. 80% Less Space Occupied Compared to Shell & Tube Designs . Design Standarts
ASME - DIN - CE - PED 97/23/EC .
Plate Heat Exchangers Plate Heat Exchangers Heat Exchangers Plate Heat Exchangers gasket
10.00
15.00
20.00 75
10
SHELL 50
SIDE
5
25
TUBE SIDE
5 10 15 gpm 20
Flow Rate
24
HVAC & INDUSTRIAL CHILLER
Air Cooled Chillers
Air cooled chillers use air to remove heat by using fans to force air across the exposed tubes of the condenser.
While air chillers require more energy than water-cooled chillers, they can be a great option when it comes to
stationary cooling. Air chillers are easy to install and typically can be installed outside a building (no extra
space requirements). Compared to water chillers, air chillers are more prone to blockages and recirculation
issues.
Air C
ooled
Reci
Air Cooled Centrifugal Chillers proca
ting C
hiller
s
rs
Chille
ressor
Co mp
Scroll
iller
s
ooled
n Ch ir C
r ive A
ewD
Scr
ed
C ool
Air
Water Cooled Chillers
Water chillers remove heat by pumping water through a sealed condenser and dispersing it through the cooling
tower. Water-cooled chillers are typically more efficient than air-cooled chillers. Using water evaporation to
dissipate heat use significantly less energy than blowing air across a hot surface. This is thanks to water’s high
heat capacity. Additionally, water chillers tend to last longer than air-cooled chillers.
Wate
rC ooled
Water Cooled Centrifugal Chillers Reci
proca
ting C
hiller
s
rs
ers C hille
r Ch
ill
riven
sso wD
ll C
om
pre
led Scre
Scro Stay Cooling, Be Smart er Coo
Cooled Wat
ter
Wa
25
OUR REPUTED CUSTOMERS
26
INSTALLATION LOCATION INSTALLATION LOCATION
To Keep the cooling tower in full swing. choose a 1. Turn the fan balde by hand to make
place according to the following conditions sure the blade tips are out of contact
a. Well--ventilated, clean. with the fan stack.
b. Exhaust air from the cooling tower is not circulated 2. Run the fan for a while and check for
and sucked again into the tower. urning direction (arrow-marked),
c. Free from much dust and dirt, sulfurous acid and unusual sound, excess vibrations etc.
other hazard gases; these are major cause to damage 3. Fill the water basin up to the top
the refrigerator condenser. level of the overflow pipe.
d. Not in the vicinity of kitchen or restroom exhaust ports, 4. Run the circulation pump for a while
or ammonia type copying machine. to force air out of the pipes until the
e. Not near smokestack or stovepipe, or radiant heat pipes and cold water basin are filled
from any other heat source. up with water. Be careful not to allow
f. Open and out not affected by sound echo. air to be suck into the cooling water
g. 2.7m or more space between the cooling tower air pipe.
inlet and the wall or other barrier.