Product Manual: Programmable LED Indicator
Product Manual: Programmable LED Indicator
MADE
                                                                                                                                                        SMARTER
Product manual
5714
Programmable LED indicator
T E M P E R AT U R E | I . S . I N T E R FA C E S | CO M M U N I C AT I O N I N T E R FA C E S | M U LT I F U N C T I O N A L | I S O L AT I O N | D I S P L AY
No. 5714V105- UK
From serial number : 1910 4 6 0 01
6 Product Pillars
to meet your every need
Individually outstanding, unrivalled in combination
With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six
product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial
and factory automation. All our products comply with or surpass the highest industry standards, ensuring reliability in even
the harshest of environments and have a 5-year warranty for greater peace of mind.
                      Our range of temperature transmitters and sensors provides the highest level of signal integrity from the
                      measurement point to your control system. You can convert industrial process temperature signals to analog, bus or
                      digital communications using a highly reliable point-to-point solution with a fast response time, automatic self-
                      calibration, sensor error detection, low drift, and top EMC performance in any environment.
                      We deliver the safest signals by validating our products against the toughest safety standards. Through our
                      commitment to innovation, we have made pioneering achievements in developing I.S. interfaces with SIL 2 Full
                      Assessment that are both efficient and cost-effective. Our comprehensive range of analog and digital intrinsically
                      safe isolation barriers offers multifunctional inputs and outputs, making PR an easy-to-implement site standard.
                      Our backplanes further simplify large installations and provide seamless integration to standard DCS systems.
                      We provide inexpensive, easy-to-use, future-ready communication interfaces that can access your PR installed base
                      of products. All the interfaces are detachable, have a built-in display for readout of process values and diagnostics,
                      and can be configured via push-buttons. Product specific functionality includes communication via Modbus and
                      Bluetooth and remote access using our PR Process Supervisor (PPS) application, available for iOS and Android.
                      Our unique range of single devices covering multiple applications is easily deployable as your site standard. Having
                      one variant that applies to a broad range of applications can reduce your installation time and training, and greatly
                      simplify spare parts management at your facilities. Our devices are designed for long-term signal accuracy, low
                      power consumption, immunity to electrical noise and simple programming.
                      Our compact, fast, high-quality 6 mm isolators are based on microprocessor technology to provide exceptional
                      performance and EMC-immunity for dedicated applications at a very low total cost of ownership. They can be
                      stacked both vertically and horizontally with no air gap separation between units required.
                      Our display range is characterized by its flexibility and stability. The devices meet nearly every demand for display
                      readout of process signals and have universal input and power supply capabilities. They provide a real-time
                      measurement of your process value no matter the industry and are engineered to provide a user-friendly and reliable
                      relay of information, even in demanding environments.
                              Programmable LED indicator
                                       5714
                                                           Table of contents
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .       4
Symbol identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  4
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               5
Front and back layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                   6
Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .         7
Technical characteristics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                    7
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .        7
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .          8
Order  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    9
Electrical specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  9
Sensor error detection / sensor error detection outside range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                                    12
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .          14
Block diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .           15
Routing diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .              17
Scrolling help text  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .             18
Configuration / operating the function keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                    20
Graphic depiction of the relay function setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                                       21
Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                  22
Document history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .               23
                                                                                                5714V105-UK                                                                                                     3
                                                 Warning
              This device is designed for connection to hazardous electric voltages.
              Ignoring this warning can result in severe personal injury or mechanical damage.
              To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and
              the guidelines followed.
              The specifications must not be exceeded, and the device must only be applied as described in the
    GENERAL   following.
              Prior to the commissioning of the device, this manual must be examined carefully.
              Only qualified personnel (technicians) should install this device.
              If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
              equipment may be impaired.
                                                 Warning
              Until the device is fixed, do not connect hazardous voltages to the device.
              The following operations should only be carried out on a disconnected device and under ESD-safe
HAZARDOUS     conditions:
 VOLTAGE            Troubleshooting the device.
                                       Symbol identification
              Triangle with an exclamation mark: Read the manual before installation and commissioning of the
              device in order to avoid incidents that could lead to personal injury or mechanical damage. Warning /
              demand. Potentially lethal situations.
The CE mark proves the compliance of the device with the essential requirements of the EU directives.
              The UKCA mark proves the compliance of the device with the essential requirements of the UK
              regulations.
The double insulation symbol shows that the device is protected by double or reinforced insulation.
4                                                 5714V105-UK
                                                Safety instructions
Definitions
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and also trouble-shoot technically correct and in
accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal
operation.
Receipt and unpacking
Unpack the device without damaging it and check whether the device type corresponds to the one ordered. The packing
should always follow the device until this has been permanently mounted.
Environment
Avoid direct sun light, dust, high temperatures, mechanical vibrations and shock, and rain and heavy moisture. If necessary,
heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation.
The device must be installed in pollution degree 2 or better.
The device is designed to be safe at least under an altitude up to 2 000 m.
The device is designed for indoor use.
Mounting
Only technicians, who are familiar with the technical terms, warnings, and instructions in the manual and who are able to
follow these, should connect the device. Should there be any doubt as to the correct handling of the device, please contact
your local distributor or, alternatively,
                                                    PR electronics A/S
                                                   www.prelectronics.com
Mounting and connection of the device should comply with national legislation for mounting of electric materials, i.e. wire
cross section, protective fuse, and location.
Stranded wire should be installed with an insulation stripping length of 5 mm or via a suitable insulated terminal such as a
bootlace ferrule.
Descriptions of input / output and supply connections are shown in the block diagram and side label.
Year of manufacture can be taken from the first two digits in the serial number.
Calibration and adjustment
During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the
specifications of this manual. The technician must use tools and instruments that are safe to use.
Normal operation
Operators are only allowed to adjust and operate devices that are safely fixed in panels, etc., thus avoiding the danger of
personal injury and damage. This means there is no electrical shock hazard, and the device is easily accessible.
Cleaning
When disconnected, the device may be cleaned with a cloth moistened with distilled water.
Liability
To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR
electronics A/S that would otherwise exist according to the concluded sales agreement.
                                                         5714V105-UK                                                            5
                            Front and back layout
6                                 5714V105-UK
                                         Programmable LED indicator
                                                  5714
Application
•	Display for digital readout of current, voltage, resistance, temperature or potentiometer signals.
• Process control with 2 pairs of potential-free relays and / or analogue output.
• For local readout in extremely wet atmospheres with a specially designed splash-proof cover.
Technical characteristics
•	4-digit LED indicator with 13.8 mm 14-segment characters. Max. display readout -1999...9999 with programmable decimal
   point, relay ON / OFF indication.
•	2.3 kVAC galvanic isolation between input, output and supply.
• All operational parameters can be adjusted to any application by use of the front keys.
• 5714 is available fully-configured acc. to specifications ready for process control and visualisation.
• Help texts in eight languages can be selected via a menu item.
•	In versions with relay outputs the user can minimise the installation test time by activating / deactivating each relay
   independently of the input signal.
Mounting
•	To be mounted in front panel. The included rubber packing must be mounted between the panel cutout hole and the
   display front to obtain a protection degree of IP65 (type 4X). For extra protection in extreme environments, 5714 can be
   delivered with a speially designed splash-proof cover as accessory.
                                                         5714V105-UK                                                          7
                                                                                 Applications
                Input signals:
                         Current
             +                                                                                    46
                                                            4      3     2
                                     Voltage                                                     44
                               +
                                                                                     TC
                                                                                                  43               1      2
                               -          +                                      +
                                                                                                  42
                                          -                                      -
                                                                                                  41
     Output signals:
                                                                                                             26
25
24
                           1          2                                         12                           23
                                                                                          +
                                                                                                             22
                                                                                          -
                                                                                11                           21
                                                                       Analog, 0/4...20 mA                 2 change over relays
Supply:
32
                                   21.6...253 VAC
                                          or
                                   19.2...300 VDC                                             1        2
31
8                                                                                     5714V105-UK
Order
Type Version
     5714            Standard                                                                  :A
                     2 relays                                                                  :B
                     Analog output                                                             :C
                     Analog output and 2 relays                                                :D
NB! Please order the splash-proof cover seperately. Order No. 8335.
Electrical specifications
Environmental conditions:
Ambient operating temperature range  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                                -20°C to +60°C
Calibration temperature  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                 20...28°C
Humidity  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .     < 95% RH (non-cond.)
Protection degree (mounted in panel)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                               IP65 / Type 4X
Mechanical specifications:
Dimensions (HxWxD)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                48 x 96 x 120 mm
Cutout dimensions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .             44.5 x 91.5 mm
Weight  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    230 g
Wire size, pin 41...46 max.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                   0.05...1.31 mm2 AWG 30...16 stranded wire
Wire size, others max.   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .              0.05...3.31 mm2 / AWG 30...12 stranded wire
Vibration  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    IEC 60068-2-6
  2...13.2 Hz  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .      ±1 mm
  13.2...100 Hz   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .         ±0.7 g
Common specifications:
Supply voltage, universal   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  21.6...253 VAC, 50...60 Hz or
                                                                                                                      19.2...300 VDC
                                    Internal
        Type                                                                Max. required power
                                power dissipation
      5714A                                2.2 W                                          2.5 W
    5714B/C                                2.7 W                                          3.0 W
      5714D                                3.2 W                                          3.5 W
General values
                                                                                                    5714V105-UK                                                                    9
                                                                     Basic values
mA ≤ ±4 μA ≤ ±0.4 μA / °C
Volt ≤ ±20 μV ≤ ±2 μV / °C
  TC type:
  E, J, K, L, N, T, U                                                ≤ ±1°C                                             ≤ ±0.05°C / °C
  TC type: R, S,
  W3, W5, LR                                                         ≤ ±2°C                                              ≤ ±0.2°C / °C
  TC type: B
  85...200°C                                                         ≤ ±4°C                                              ≤ ±0.4°C / °C
  TC type: B
  200...1820°C                                                       ≤ ±2°C                                              ≤ ±0.2°C / °C
Auxiliary supply:
2 wire supply, pin 46...45   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  > 15 VDC @ 0...20 mA
TC input
Cold junction compensation (CJC) via internal sensor  .  .  .  .  .  .  .  .  .  .  .  .  .  .                                         ±(2.0°C + 0.4°C * Δt)
Δt = internal temperature - ambient temperature
Sensor error detection, all TC types  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                           Yes
Sensor error current:
 when detecting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .               Nom. 2 μA
 else  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    0 μA
10                                                                                                    5714V105-UK
RTD, linear resistance and potentiometer input
                                                                                                   5714V105-UK                                                            11
 Relay outputs
 Relay function .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .             Setpoint
 Hysteresis   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .         0...100%
 On and Off delay  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                0...3600 s
 Sensor error detection  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                   Make / Break / Hold
 Max. voltage  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .           250 VAC / VDC
 Max. AC current  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .              2A
 Max. AC power  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                500 VA
 Max. DC current, resistive load:
  @ Urelay ≤ 30 VDC  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                 2 ADC
                                                                                                                                                   -2            U
  @ Urelay >30 VDC  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                  [1380 x Urelay x 1.0085 relay] ADC
                                                        -2                      Urelay
 Graphic depiction of [1380 x Urelay x 1.0085                                            ]:
3.00 A
2.00 A
           1.00
             1,00 A
                  A
          0.80 A
Current
          CURRENT
0.60 A
0.40 A
0.20 A
           0.10
             0,10 A
                  A
                    0V
                      0          50
                                 50 V
                                                  100
                                                  100 V
                                                                    150
                                                                    150 V
                                                                                      200
                                                                                      200 V
                                                                                                        250
                                                                                                        250 V
                                                                                                              VDC
                                                        Urelay
                                                      URELAY
 12                                                                                                     5714V105-UK
                                      Outside range readout (IN.LO, IN.HI):
                     If the valid range of the A/D converter or the polynomial is exceeded
     Input                           Range                            Readout                     Limit
                                                                       IN.LO                     < -25 mV
                                0...1 V / 0.2...1 V
                                                                        IN.HI                    > 1.2 V
     VOLT
                                                                       IN.LO                     < -25 mV
                                0...10 V / 2...10 V
                                                                        IN.HI                     > 12 V
                                                                       IN.LO                    < -1.05 mA
     CURR                     0...20 mA / 4...20 mA
                                                                        IN.HI                   > 25.05 mA
                                                                       IN.LO                     < -0.5%
     POTM                                -
                                                                        IN.HI                   > 100.5%
                                                                       IN.LO           < temperature range -2°C
     TEMP                           TC / RTD
                                                                        IN.HI          > temperature range +2°C
                                                                       IN.LO                     < 0 ohm
                                   0...800 ohm
                                                                        IN.HI                    > 1 kohm
     LIN. R
                                                                       IN.LO                     < 0 ohm
                                   0...10 kohm
                                                                        IN.HI                   > 15 kohm
! Error indications in the display blink once a second. The help text explains the error.
                                                           5714V105-UK                                             13
                                   Connections
Inputs:
          RTD & Lin R, 2-wire     RTD & Lin R, 3-wire             RTD & Lin R, 4-wire
     41 42 43 44 45 46          41 42 43 44 45 46               41 42 43 44 45 46
      -        +                                 -        +       -           +
                                                     Tx
               Voltage              Potentiometer
     41 42 43 44 45 46          41 42 43 44 45 46
- +
                                                      Output:
     Supply:
                                           Current                      Relays
      31 32                            11 12                    21 22 23 24 25 26
                                       -
                                            mA   +
                                                                 R1              R2
14                                    5714V105-UK
                                          2-wire supply
                                            > 15 VDC       46                                                    32   Supply
                                                                                                                      21.6...253 VAC
                                      +                                                                                      or
                                                                                                                      19.2...300 VDC
                                     Tx                                                                          31
                                                                                                                      Supply
                                               Input +,
                                                 mA        45                   Version D                        12   I+
                                                                   PTC
                                                                                                                           mA
                                                                                                                 11
                                                                    20 W
                                                +                                                                       I
                                                                                                                      Output
                                                                                            1   2   3   4
5714V105-UK
                                                                           AD    CPU
                                                                                                                                       Block diagram
              1
                                                           42
                                                           41                     5714
                                              Input gnd.
15
 Power up
                           ADV.SET         POTM                                                3
                                           CURR 3 RANG
1.0 = Default state
                                                        1 2
1.1 = Only if password-protected
1.2 = Only is FastSet is enabled                     0-20 4-20                                 3
1.3 = FastSet and relay test
       disabled at password                VOLT 3 RANG
       5000...9999.                                     1 2
1.4 = No relay outputs                               0-1 0.2-1                                                        1.6
1.5 = Not valid for these input                     0-10 2-10                                 3
       signals: Potentiometer,
       0...20 mA and voltage               LIN.R 3 LR.LO               LR.HI           CONN                           1.4
1.6 = No analog output                                   1 2 3 1 2 3 1 2
1.7 = Only if input signal is                                                 3
       temperature
                                                        0-9998 1-9999 2W 3W 4W
1.8 = In default state press and
       hold 1 or 2 to change               TEMP 3 TYPE
       display intensity between                         1 2
       damped and full
       (7 = full intensity).
                                            PT     3    PT.TY          CONN
                                                         1 2 3 1 2
                                                       10-1000 2W 3W 4W              3
                                            NI     3    NI.TY          CONN
                                                         1 2 3 1 2
                                                       50-1000 2W 3W 4W             3
                                            TC     3 TC.TY                          3          DEC.P            UNIT
                                                        1 2                                     1 2             1 2
                                                 TC.B-E-J-K-L-N-R
                                                                                                          3             3
                                                                                                1111             'C
                                                 S-T-U-W3-W5-LR                                 111.1            'F
                                            CU     3    CU.TY           CONN
                                                         1 2      3    1 2
                                                        10-100       2W 3W 4W        3
16                                                 5714V105-UK
                                                         Routing diagram
     If no keys are activated for 2 minutes the display returns to default state 1.0 without saving configuration changes.
     1 Increase value / choose next parameter.
     2 Decrease value / choose previous parameter.
     3 Accept the chosen parameter and go to the next menu.
     Hold 3 Back to previous menu / return to menu 1.0 without saving.
                                                                        1.5
    REL.1              SETP              ACT1               HYS1               ERR1               ON.DE                OF.DE
     1 2                1 2                1 2               1 2                  1 2                 1 2              1 2
     SET        3        0.0
                                   3       INCR
                                                       3      0.0
                                                                         3        HOLD
                                                                                            3         0000
                                                                                                              3        0000
                                                                                                                                3
     SKIP               100.0              DECR              100.0                ACTI                3600             3600
3    OFF                                                                          DEAC
                                                                                  NONE
                                                                             1.5
             REL.2            SETP             ACT2                HYS2            ERR2               ON.DE            OF.DE
              1 2              1 2               1 2               1 2              1 2                1 2              1 2
              SET       3       0.0
                                          3      INCR
                                                           3        0.0
                                                                              3     HOLD
                                                                                              3        0000
                                                                                                               3        0000
                                                                                                                                3
              SKIP             100.0             DECR              100.0            ACTI               3600             3600
       3      OFF                                                                   DEAC
                                                                                    NONE
    1.6
                                                                                           1.6
    1.4                 1.7              1.7               1.5
             A.OUT              O.LO             O.HI            O.ERR             RESP               E.PAS             N.PAS
              1 2              1 2               1 2              1 2                1 2               1 2              1 2
              4-20      3      a999
                                          3      a999
                                                           3     0/3.5mA      3       0.0
                                                                                                3      YES
                                                                                                                   3    0000
                                                                                                                                3
              0-20             9999              9999             23mA               60.0               NO              9999
              20-4                                                NONE                                             NO
              20-0
                                                DE   DK
                                LANG            ES   FR                                     To default state 1.0        ----
            ADV.SET             DISP            IT   SE
                                 CAL            UK   CZ
                                 12               12
                              LANG 3              UK       3
                                                 HLP.T
                                                 1...7
                                                 12
                       1.8 DISP           3        7       3
                                                 LIGH
                                                                   100.0                              100.0
                                                YES NO              0.0            YES NO              0.0         YES NO
                                                 12                 12              12                 12           12
NO NO
                                                              5714V105-UK                                                       17
                                          Scrolling help text
Display in default state xxxx, hardware error:         DI.HI
SE.BR --> SENSOR WIRE BREAKAGE                         xxxx    -->   DISPLAY READOUT HIGH
SE.SH --> SENSOR SHORT CIRCUIT
IN.HI    --> INPUT OVERRANGE                           REL.U		
IN.LO    --> INPUT UNDERRANGE                          PERC  --> SET RELAY IN PERCENTAGE
9.9.9.9 --> DISPLAY OVERRANGE                          DISP  --> SET RELAY IN DISPLAY UNITS
-1.9.9.9 --> DISPLAY UNDERRANGE                        		
HW.ER --> HARDWARE ERROR                               TYPE		
EE.ER --> EEPROM ERROR - CHECK CONFIGURATION           CU    --> SELECT CU SENSOR TYPE
RA.ER --> RAM MEMORY ERROR                             PT    --> SELECT PT SENSOR TYPE
CJ.ER     --> CJC SENSOR ERROR                         NI    --> SELECT NI SENSOR TYPE
                                                       TC    --> SELECT TC SENSOR TYPE
Fastset (Enabled):
F.SET		                                                CU.TY		
REL1     --> FAST SET MENU -                           10    --> SELECT CU SENSOR TYPE
REL2     --> SELECT RELAY                              20    --> SELECT CU SENSOR TYPE
                                                       50    --> SELECT CU SENSOR TYPE
SETP		                                                 100   --> SELECT CU SENSOR TYPE
xxxx --> RELAY SETPOINT - PRESS OK TO SAVE             		
                                                       PT.TY		
Fastset (Disabled):                                    10    --> SELECT PT SENSOR TYPE
SETP		                                                 20    --> SELECT PT SENSOR TYPE
xxxx     --> RELAY SETPOINT - READ ONLY                50    --> SELECT PT SENSOR TYPE
                                                       100   --> SELECT PT SENSOR TYPE
Configuration menus:                                   200   --> SELECT PT SENSOR TYPE
ADV                                                    250   --> SELECT PT SENSOR TYPE
YES     --> ENTER ADVANCED SETUP MENU?                 300   --> SELECT PT SENSOR TYPE
NO                                                     400   --> SELECT PT SENSOR TYPE
                                                       500   --> SELECT PT SENSOR TYPE
PASS		                                                 1000  --> SELECT PT SENSOR TYPE
xxxx --> SET CORRECT PASSWORD                          		
                                                       NI.TY		
IN		                                                   50    --> SELECT NI SENSOR TYPE
C.LIN* --> TEXT ENTERED BY USER IN PRESET              100   --> SELECT NI SENSOR TYPE
CURR --> CURRENT INPUT                                 120   --> SELECT NI SENSOR TYPE
VOLT   --> VOLTAGE INPUT                               1000  --> SELECT NI SENSOR TYPE
POTM --> POTENTIOMETER INPUT                           		
LIN.R  --> LINEAR RESISTANCE INPUT                     CONN		    When Cu, Pt and Ni sensor is selected
TEMP --> TEMPERATURE SENSOR INPUT                      2W    --> SELECT 2-WIRE SENSOR CONNECTION
		                                                     3W    --> SELECT 3-WIRE SENSOR CONNECTION
RANG		     When current selected:                      4W    --> SELECT 4-WIRE SENSOR CONNECTION
0-20   --> INPUT RANGE IN mA
4-20   --> INPUT RANGE IN mA                           TC.TY		
		                                                     TC. B  --> SELECT TC SENSOR TYPE
RANG		     When voltage selected:                      TC. E  --> SELECT TC SENSOR TYPE
0-10   --> INPUT RANGE IN VOLT                         TC. J  --> SELECT TC SENSOR TYPE
2-10   --> INPUT RANGE IN VOLT                         TC. K  --> SELECT TC SENSOR TYPE
0.0-1  --> INPUT RANGE IN VOLT                         TC. L  --> SELECT TC SENSOR TYPE
0.2-1  --> INPUT RANGE IN VOLT                         TC. N  --> SELECT TC SENSOR TYPE
		                                                     TC. R  --> SELECT TC SENSOR TYPE
DEC.P		                                                TC. S  --> SELECT TC SENSOR TYPE
1111   --> DECIMAL POINT POSITION                      TC. T  --> SELECT TC SENSOR TYPE
111.1 --> DECIMAL POINT POSITION                       TC. U  --> SELECT TC SENSOR TYPE
11.11 --> DECIMAL POINT POSITION                       TC.W3 --> SELECT TC SENSOR TYPE
1.111 --> DECIMAL POINT POSITION                       TC.W5 --> SELECT TC SENSOR TYPE
                                                       TC.LR --> SELECT TC SENSOR TYPE
LR.LO		                                                		
xxxx  -->     SET RESISTANCE VALUE LOW                 DEC.P		    When temperature selected
                                                       1111   --> DECIMAL POINT POSITION
LR.HI                                                  111.1 --> DECIMAL POINT POSITION
xxxx    -->   SET RESISTANCE VALUE HIGH
                                                       UNIT		
DI.LO		                                                °C   --> DISPLAY AND RELAY SETUP IN CELSIUS
xxxx  --> DISPLAY READOUT LOW                          °F   --> DISPLAY AND RELAY SETUP IN FAHRENHEIT
18                                               5714V105-UK
REL1		                                           O.HI		
SET   --> ENTER RELAY 1 SETUP                    xxxx --> DISPLAY VALUE FOR OUTPUT HIGH
SKIP  --> SKIP RELAY 1 SETUP
OFF   --> RELAY 1 DISABLED                       O.ERR		
		                                               23 mA --> NAMUR NE43 UPSCALE AT ERROR
SETP		                                           3,5 mA --> NAMUR NE43 DOWNSCALE AT ERROR
xxxx  --> RELAY SETPOINT                         0mA    --> DOWNSCALE AT ERROR
		                                               NONE --> UNDEFINED OUTPUT AT ERROR
ACT1		                                           		
INCR  --> ACTIVATE AT INCREASING SIGNAL          RESP		
DECR  --> ACTIVATE AT DECREASING SIGNALL         xxx.x  --> ANALOGUE OUTPUT RESPONSE TIME
		                                               		         IN SECONDS
HYS1		                                           		
xxxx  --> RELAY HYSTERESIS                       E.PAS		
		                                               NO     --> ENABLE PASSWORD PROTECTION
ERR1		                                           YES
HOLD --> HOLD RELAY AT ERROR                     		
ACTI  --> ACTIVATE RELAY AT ERROR                N.PAS		
DEAC  --> DEACTIVATE RELAY AT ERROR              xxxx   --> SELECT NEW PASSWORD
NONE --> UNDEFINED STATUS AT ERROR
		
ON.DE		                                          ADV MENU:
xxxx  --> RELAY ON-DELAY IN SECONDS              LANG -->      ENTER LANGUAGE SETUP
		                                               DISP   -->    ENTER DISPLAY SETUP
OF.DE		                                          CAL    -->    PERFORM PROCESS CALIBRATION
xxxx  --> RELAY OFF-DELAY IN SECONDS
		                                               HLP.T
REL2		                                           DE    -->     DE - WAEHLE DEUTSCHEN HILFETEXT
SET   --> ENTER RELAY 2 SETUP                    DK    -->     DK - VAELG DANSK HJAELPETEKST
SKIP  --> SKIP RELAY 2 SETUP                     ES    -->     ES - SELECCIONAR TEXTO DE
OFF   --> RELAY 2 DISABLED                       		            AYUDA EN ESPANOL
                                                 FR    -->     FR - SELECTION TEXTE D’AIDE
SETP		                                           		            EN FRANCAIS
xxxx  --> RELAY SETPOINT                         IT    -->     IT - SELEZIONARE TESTI DI
		                                               		            AIUTO ITALIANI
ACT2		                                           SE    -->     SE - VALJ SVENSK HJALPTEXT
INCR  --> ACTIVATE AT INCREASING SIGNAL          UK    -->     UK - SELECT ENGLISH HELPTEXT
DECR  --> ACTIVATE AT DECREASING SIGNAL          CZ    -->     CZ - VYBER CESKOU NAPOVEDU
		
HYS2		                                           LIGH
xxxx  --> RELAY HYSTERESIS                       xxxx    -->   ADJUST DISPLAY LIGHT INTENSITY
		
ERR2		                                           CA.LO		
HOLD --> HOLD RELAY AT ERROR                     YES   --> CALIBRATE INPUT LOW TO PROCESS
ACTI  --> ACTIVATE RELAY AT ERROR                		VALUE?
DEAC  --> DEACTIVATE RELAY AT ERROR              NO
NONE --> UNDEFINED STATUS AT ERROR               		
		                                               CA.HI		
ON.DE		                                          YES   --> CALIBRATE INPUT HIGH TO PROCESS
xxxx  --> RELAY ON-DELAY IN SECONDS              		VALUE?
		                                               NO
OF.DE		
xxxx  --> RELAY OFF-DELAY IN SECONDS             VAL.L		
                                                 xxxx  --> SET VALUE FOR LOW CALIBRATION
A.OUT		                                          		POINT
0-20  -->   OUTPUT RANGE IN mA
4-20  -->   OUTPUT RANGE IN mA                   VAL.H		
20-0  -->   OUTPUT RANGE IN mA                   xxxx  --> SET VALUE FOR HIGH CALIBRATION
20-4  -->   OUTPUT RANGE IN mA                   		POINT
O.LO		                                           USE.C		
xxxx --> DISPLAY VALUE FOR OUTPUT LOW            YES   -->     USE PROCESS CALIBRATED VALUES?
                                                 NO
                                           5714V105-UK                                           19
                             Configuration / operating the function keys
Documentation for routing diagram.
In general
When configuring the display you are guided through all parameters, you can choose the settings which fit the application.
For each menu there is a scrolling help text which is automatically shown in the display, this starts after 5 seconds if no key
has been activated.
If a function does not exist in the display all parameters are skipped to make the configuration as simple as possible.
Once the configuration has been entered the display will show “----”.
Pressing and holding 3 will return to the previous menu or return to the default state (1.0) without saving the changed values
or parameters.
If no key is activated for 2 minutes, the display will return to the default state (1.0) without saving the changed values or
parameters.
Further explanations
Fast setpoint adjustment and relay test: These menus allow you to change the set point quickly and to check the operation
of the relays.
Pressing 1 and 2 at the same time will change the state of the relay – this change is indicated by the diodes on the display.
Pressing 3 will save the set point change.
Holding down 3 for more than 0.5 seconds will return the unit to the default state without changing the set point.
Password protection: Using a password will stop access to the menu and parameters. There are two levels of password
protection. Passwords between 0000…4999 allow access to the fast set point adjustment and relay test. (Using this
password stops access to all other parts of the menu). Passwords between 5000…9999 stop access to all parts of the menu,
fast set point and relay test. (Current set point is still shown). If the configured password is not known, please contact PR
electronics support - www.prelectronics.com/contact.
20                                                        5714V105-UK
                                Graphic depiction of the relay function setpoint
100                                                                                    100
          Relay units                                                                            Relay units
90                                                                                     90
80 80
70 70
60                                                                                     60
                                                                                                               Hysteresis = 10
50                                                                                     50
                             Setpoint = 50                                                                      Setpoint = 50
40                                                                                     40
                             Hysteresis = 10
30                                                                                     30
20 Off N.O. On N.O. Off N.O. 20 Off N.O. On N.O. Off N.O.
                                                                              5714V105-UK                                                                       21
                                                                            Installation instructions
UL installation requirements
For use on a flat surface of a type 1 enclosure
Use 60/75°C copper conducters only
Enclosure rating (face only) acc. to UL50E  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                            Type 4X
Max. ambient temperature  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .                   60°C
Max. wire size, pins 41...46  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .               AWG 30-16
Max. wire size, others  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .            AWG 30-12
UL file number  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .        E248256
Relay outputs:
Max. voltage  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    250 VRMS
Max. current  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .    2 A / AC
Max. AC power  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .         500 VA
Max. current at 24 VDC  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .               1A
22                                                                                                5714V105-UK
                                                 Document history
The following list provides notes concerning revisions of this document.
Rev. ID                                Date  Notes
104                                    1933	Relay data updated, graph with resistive loads
                                             inserted.
                                             EU-RO marine approval added.
105                                    2208  UKCA approval added.
We are near you,
all over the world
Our trusted red boxes are supported wherever you are
All our devices are backed by expert service and a 5-year    business with a global reach. This means that we are
warranty. With each product you purchase, you receive        always nearby and know your local markets well.
personal technical support and guidance, day-to-day          We are committed to your satisfaction and provide
delivery, repair without charge within the warranty period   PERFORMANCE MADE SMARTER all around the world.
and easily accessible documentation.
                                                             For more information on our warranty program, or to meet
We are headquartered in Denmark, and have offices and        with a sales representative in your region, visit
authorized partners the world over. We are a local           prelectronics.com.
Benefit today from
PERFORMANCE MADE SMARTER
Our innovative, patented technologies are derived from our extensive R&D facilities and
from having a great understanding of our customers’ needs and processes. We are guided
by principles of simplicity, focus, courage and excellence, enabling some of the world’s
greatest companies to achieve PERFORMANCE MADE SMARTER.
www.prelectronics.com