mico
Solutions for Intelligent
Power Distribution
ÔÔ
Monitor
ÔÔ
Detect
ÔÔ
Switch Off
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
02 | 03
vital to your system
Thousands of satisfied customers Murrelektronik offers you...
Control cabinet construction Transformers
Machine tools Switch mode power supplies
Packaging industry Intelligent power distribution
Logistics Buffer module
Process automation Redundancy modules
Food&Beverage
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
| SOLUTIONS FOR
INTELLIGENT POWER DISTRIBUTION
Complex power supply systems with many components require reliable
load protection. Switch mode power supplies are the core of these systems
since they electronically monitor output voltage and output current. If
there is a short circuit or an overload, protective devices downstream (for
example circuit breakers) react slower than the power supply and do not
ensure selectivity. This can cause critical situations like voltage drops or
even cable fires.
Our compact MICO modules help eliminate these problems: MICO is an
essential component for protecting power supply systems!
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
04 | 05
| MICO – Solutions for intelligent power distribution
CASCADING START
MICO eliminates start-up peaks with a time-delayed
(cascading) start of individual current paths. Advantage:
Now you can use power supplies with lower output
current.
I nom (A )
competitor
MICO
100 %
70 %
channel 1 channel 2 channel 3 channel 4
Target-oriented protection is a big challenge for modern power supply systems. MICO is an intelligent power
distribution system that meets this challenge! Errors are found quickly while availability remains high.
MICO Monitors Currents: You can select a maximum, individual current value for each
channel and MICO monitors this value. The LED is green when the current is OK.
MICO Indicates When Approaching the Maximum Load: There is a visual alarm when
90 % of the selected current load is reached. The LED blinks green.
MICO Detects Stress: When there are short circuits or if the selected load current is excee-
ded, MICO switches the affected channel off. The LED blinks red.
MICO Provides Flexibility: Each channel can be individually switched off by pressing a but-
ton. Here, the LED is red. Of course, you also can switch all channels on manually.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Example for a 6 A circuit breaker in a 24 V DC system
Distributor cable
Incoming cable 0.34 mm2/10 m
Outgoing cable 0.75 mm /10 m
Installation wire LSS* 6A Passive Sensor cable
1.5 mm2/3m Ri=0.06 Ω Distribution Box 0.34 mm2 / 5m
R=10m Ω per
terminal
connection
* Circuit breaker
Specific resistance of copper ( ) = 0.0178 (Ω x mm2 /m)
0.0178 x (2x3 m)
Wire resistance: R= = = 0.07
A 1.5 mm2
0.0178 x (2x10 m)
Distributor cable resistance: R= = = 0.65
A (0.34 + 0.75 mm2)/2
Sensor cable resistance: R= = 0.0178 x (2x5 m) = 0.52
A 0.34 mm2
Inner resistance of circuit breaker and connection terminals = 0.08
Total loop resistance = 1.32
U 24 V
Calculation of maximum possible current flow I= = = 18.18 A
(limited by loop resistance) R 1.32
Required tripping current of the 6 A circuit breaker Type C Tripping current Max. current flow
14 x INom = 14 x 6 A = 84 A 84 A > 18.18 A
| The Perfect MICO for Any Application
Description MICO+ MICO CLASSIC MICO BASIC MICO FUSE
Electronic current monitoring x x x
Monitoring with glass tube fuse x
2 output channels x
4 output channels x x x
8 output channels x x
Adjustable current ranges x x
Spring clamp terminals x x x x
Bridge system on both sides x x
Bridge system left x
90 % warning notice with blinking LED x x x
90 % warning notice as digital signal x
Channel switch off by signal x
Group alarm contact (potential-free) x
Group alarm contact (digital output) x x x
Cascading start of the individual current paths x x x
UL Approval x x x
For more information see our online shop
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
06 | 07
| MICO+ – appealing features and even more options
Mico saves energy: When loads are switched
on, they need energy. Often current is already
flowing, even though no productive activity is
carried out. For example during pause times:
Energy is consumed as stand-by power, pumps
are running, displays lighten, loads are heating ...
With MICO+ you can switch off all 4 output
channels from a control input during idle times.
This way, only those loads that actually require
energy are supplied. This saves energy, results in
fewer losses, increases lifetime and productivity.
If the part of the machine that was switched off
is needed again, it can be immediately reactiva-
ted with MICO+.
MICO+ MICO Classic MICO BASIC MICO FUSE
| Model Overview
Art. No. Description Current ranges (adjustable)
9000-41084-0100400 MICO+ 4.4 (4 channels) 1A/2A/3A/4A
9000-41084-0100600 MICO+ 4.6 (4 channels) 1A/2A/4A/6A
9000-41084-0401000 MICO+ 4.10 (4 channels) 4A/6A/8A/10A
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
YOUR BENEFITS
% warning notice – now available as digital signal: MICO's visual
90
90 % warning notice is a perfect tool for setting up machines and
Save energy during idle times
systems. If channels are near the limit, the LED starts blinking. Often
the total current needed increases during operation. This happens React early to creeping failures
for example, because valves and motors wear out. Therefore, the
Create single channel diagnostics
MICO+ 90 % warning notice is additionally available as signal. The
signal is transferred to the control, the control sets off the alarm – Ideal switch off behavior
and counter-measures can be immediately taken.
Flexibly adjustable current ranges
Capacitive load per channel 20,000 μF
New connection terminals on the outputs: Two connection options
Group alarm contact
are available per channel. With MICO+ you can connect twice as
many loads compared to MICO Classic. It's also easy to create 90 % warning notice, shown by a
features such as single channel monitoring: one wire to the load, the blinking LED
other wire to the control's input – it doesn't get any easier
Unique bridge system
than that!
Cascading start of individual current
paths
Non-volatile error memory
ON Manual switch-off and -on by
pressing a button
OFF
24 VDC 90 %
13 (Fail)
GND (OV) OUT 1-4
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
08 | 09
| MICO CLASSIC – Top Class Power Distribution
Allows remote start with 24 V DC signal
Manually switch on each channel for start-up and shut-down
LED status indication for each channel
Proven bridge concept connects several MICOs
Minimum output resistance, almost no power loss
Optimum labeling options, for device location and channels
Maintenance-free with spring clamp terminals
Adjustable current range for each channel
Perfect shut-down function: as late as possible, as early as
necessary
Visual warning notice when 90 %
Less is more
of the load current set is reached
Potential-free alarm output
75 %
Temperature does not affect MICO
No current limits
| MICO CLASSIC 4.10 Speed-Start
– READY TO GO AT ANY TIME
Circuit breaker MICO CLASSIC
With its optimized start-up behavior, MICO CLASSIC 4.10 Speed-Start
powers very sensitive loads without any noticeable interruption, for
example with: fieldbus systems, industrial computers, controls or drive
controls. This eliminates any problems that happen when loads are
switched off automatically.
30.000
µF
Did You Know?
With MICO CLASSIC 4.10 Speed-Start, you can handle capacitive loads of up to 30,000 μF per
channel. It can protect up to 15 drive controls per channel without any problems!
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
| MICO CLASSIC 4.4.10 Actuator Sensor – FOR ANY APPLICATION
MICO CLASSIC 4.4.10 Actuator-Sensor features two channels to
protect sensors (current range 1 to 4 A) and two channels
PERFECT FIT
to protect actuators (4 to 10 A). It covers the complete current
range from 1 - 10 A in one compact device!
MICO CLASSIC is available in a
two channel and four channel
version: The modules can be in-
stalled in any combination to en-
1…10 A
sure a cost-effective and space-
saving system design.
They are linked with a bridge set.
This minimizes wiring efforts.
2 channels, width 36 mm
4 channels, width 70 mm
MICO+ MICO Classic MICO BASIC MICO FUSE
| Model Overview
Art. No. Description Current ranges (adjustable)
9000-41042-0100400 MICO CLASSIC 2.4 (2 channels) 1A/2A/3A/4A
9000-41042-0100600 MICO CLASSIC 2.6 (2 channels) 1A/2A/4A/6A
9000-41042-0401000 MICO CLASSIC 2.10 (2 channels) 4A/6A/8A/10A
Art. No. Description Current ranges (adjustable)
9000-41034-0100400 MICO CLASSIC 4.4 (4 channels)* 1A/2A/3A/4A
9000-41034-0100600 MICO CLASSIC 4.6 (4 channels)* 1A/2A/4A/6A
9000-41034-0401000 MICO CLASSIC 4.10 (4 channels)* 4A/6A/8A/10A
Art. No. Description Current ranges (adjustable)
9000-41034-0101000 MICO CLASSIC 4.4.10 Actuator-Sensor 2 x 1A/2A/3A/4A, 2 x 4A/6A/8A/10A
9000-41034-0401005 MICO CLASSIC 4.10 Speed-Start 4A/6A/8A/10A
* GL approval
| Accessories
Art. No. Description Other
9000-41034-0000002 Bridge set 1 set
9000-41034-0000001 Bridge set 10 sets
9000-41034-0000003 Shortened button 4 buttons
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
10 | 11
| MICO BASIC – INTELLIGENT SWITCH OFF
As early as necessary, as late as possible – MICO BASIC features intelligent switch off characteristics! The modules are
suitable for any application that requires protection of a great number of sensors and actuators with similar demands.
The current ranges for the individual circuits are fixed. The compact modules secure either four or eight channels with
2, 4, or 6 A. LEDs show the operating conditions of the individual channels and, when blinking, indicate that a maximum
load of 90 % is reached. If there is an overload or short circuit, MICO BASIC switches the affected channel off and the
LED blinks red. A group alarm contact sends the current status to the control.
Switch off supported by microprocessor
Preset tripping currents – 2 A
(the same for all channels) – 4A
– 6A
4 channels – width 35 mm
8 channels – width 70 mm
Less space required compared to conventional solutions
Spring clamp terminals with bridging option on the left side (24 V
and GND)
Group alarm contact through digital output
20,000 µF maximum capacitive load per channel
Labeling options for each channel and for the module
Visual warning notice when 90 % of the load current set is reached
Cascading start of the individual current paths
MICO+ MICO Classic MICO BASIC MICO FUSE
|| model
modeloverview
overview
Art. No. Description Current range (preset)
9000-41064-0200000 MICO BASIC 4.2 (4 channels) 2A
9000-41064-0400000 MICO BASIC 4.4 (4 channels) 4A
9000-41064-0600000 MICO BASIC 4.6 (4 channels) 6A
Art. No. Description Current range (preset)
9000-41068-0200000 MICO BASIC 8.2 (8 channels) 2A
9000-41068-0400000 MICO BASIC 8.4 (8 channels) 4A
9000-41068-0600000 MICO BASIC 8.6 (8 channels) 6A
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
| MICO FUSE – COST-EFFECTIVE MONITORING WITH GLAS TUBE FUSES
Protecting sensors and actuators is very important. However, using individual safety terminals requires
time-consuming efforts. Now MICO FUSE makes this protection more convenient! The compact module
features eight sockets for glass tube fuses that can be accessed from the front. It protects
eight channels.
MICO FUSE 24 LED has additional LEDs that indicate the operating condition of
each channel in red and green. A group alarm contact sends the current status
to the control.
8 Sockets for – accessible from the front
glass tube fuses (5 x 20 mm)
Minimum space required per channel
MICO FUSE 24 LED
– Operating voltage: 24 V DC
– Channel-specific LED indicator
Green = fuse OK
Red = fuse defective
– Group alarm contact through digital output
MICO FUSE 250 – Operating voltage: 0…250 V AC/DC
Common voltage for all channels – reduces wiring efforts
Max. total current 40 A
Spring clamp terminals – maintenance-free and vibration proof
Labeling options for each channel and for the module
MICO+ MICO Classic MICO BASIC MICO FUSE
| model overview
Art. No. Description Other
9000-41078-0600001 MICO FUSE 24 LED Delivered without fuses
With LED indicator and alarm contact
9000-41078-0600002 MICO FUSE 250 Delivered without fuses
Universal model from 0…250 V AC/DC
| Accessories
Art. No. Description Other
9000-41078-0000002 MICO FUSE Spare fuse – 2 A* 8 pcs.
9000-41078-0000004 MICO FUSE Spare fuse – 4 A* 8 pcs.
9000-41078-0000006 MICO FUSE Spare fuse – 6 A* 8 pcs.
9000-41078-0000010 MICO FUSE Fuse socket cover 8 pcs.
*Slow blow
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
MICO – Solutions for Intelligent Power Distribution|09_12 EN|Art. No. 9843022
The information in this brochure has been compiled with the utmost care. Liability for the correctness, completeness
and topicality of the information is restricted to gross negligence.
www.murrelektronik.com
ÔÔ
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr