Apr.
12 LHBL-P1
TSURUMI PUMP LH - SERIES SPECIFICATIONS
DEWATERING PUMP
FEATURES
1. Semi-open, high chrome iron overloading or accidental
impeller with replaceable / run -dry conditions.
adjustable high chrome Iron
wear rings, increases wear 5. Double shielded, permanently
resistance, when pumpage lubricated, high temperature
contains abrasive particles. C3 ball bearings rated for a
B-10 life of 60,000 hours,
2. Double inside mechanical seals extend operational life.
with silicon carbide faces, (both
top and bottom) running in an 6. Top discharge, flow-thru
oil filled chamber and further design enables operation at
protected by a lip seal running low water levels for extended
against a replaceable, 430 periods.
stainless steel shaft sleeve,
provides for the most durable APPLICATIONS
seal design available. 1. Commercial, industrial
wastewater and construction
3. Highly efficient, continuous duty site drainage.
air filled, copper wound motor
with class B, F insulation 2. Effluent transfer.
minimizes the cost of operation.
3. Decorative waterfalls and
4. Built in thermal & amperage fountains.
sensing protector prevents
motor failure due to 4. Raw water supply from rivers
or lakes.
SPECIFICATIONS STANDARD OPTIONS
Discharge Size 3” ~ 8” NPT (80 mm ~ 200 mm)
Horsepower Range 4 ~ 150 HP. (3 ~ 110 Kw)
Performance Range Capacity 26.4 ~ 1717.0 GPM. (0.1 ~ 6.5 m3/min)
Head 20.5 ~ 604.0 Ft. (6.25 ~ 184.1m)
Maximum water temperature 1040 F. (400 C.)
Materials of Construction
Casing Cast Iron , Ductile Cast Iron
Impeller High Chrome Cast Iron
Shaft 420 Stainless Steel
Motor Frame Cast Iron
Fasteners 304 Stainless Steel
Seal Pressure Relief Ports 50 - 150HP (37 - 110 kW)
Mechanical Seal Silicon Carbide
Elastomers NBR (Nitrile Butadiene Rubber)
Impeller Type Semi-open, solids handling.
Solids Handling Capability 0.236 - 0.787” (6 - 20mm)
Bearings Prelubricated, Double Shielded
Motor Nomenclature
Type, Speed, Hz. Air Filled, 3600 RPM, 60 Hz.
Voltage, Phase 208/230/460/575 V., 3 Phase.
Insulation Class B , F
Accessories Submersible Power Cable Length as Required.
50 - 65’ (15 - 20m)
Operational Mode Manual TS-303 Float Switch
Nov. 13 60-PC-LH-00
LH - SERIES PERFORMANCE
TSURUMI PUMP DEWATERRING PUMP RANGE
GROUP PERFORMANCE RANGE
m Ft
800
240
220
700
LH
41
10
W
60 Hz
200
600 LH 611
180 0
160
500
LH 690
140
TOTAL HEAD
LH 675
120 400
100
LH 8
300 110
80 LH430 LH
6 45 LH 89
0
LH 87
200 LH 5
60 4
LH
22
6
LH 8
37
55
40
LH 8
45
100 LH 8
LH LH 37
LH 6 62
20 3 3. 0 15 2
LH6
1 9
0 0
US GPM 0 200 400 600 800 1000 1200 1400 1600 1800
m3/min 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
CAPACITY
Jan. 13 60-PC-LH-15
LH - SERIES PERFORMANCE
TSURUMI PUMP DEWATERING PUMPS CURVE
MODEL BORE HP KW RPM SOLIDS DIA LIQUID SG. VISCOSITY TEMP.
LH6110-61 6”/150mm 150 110 3570 0.236”/6mm Water 1.0 1.123 cSt. 60oF
PUMP TYPE PHASE VOLTAGE AMPERAGE HZ STARTING METHOD INS. CLASS
Dewatering Pump 3 460 / 575 181 / 145 60 Star-Delta F
CURVE No. DATE PHASE VOLTAGE AMPERAGE HZ STARTING METHOD INS. CLASS
- - - - - - - -
EFF. 210
700
TOTAL HD. REMARKS:
% M. Ft.
200 650
190
600 TH-Q
180
170 550
160
100 500
150
140
90 450
130
80 120 400
110
70 350
100
60 90 300
80
50 250
70
40 60 200
50
30 150
40 F.
EF
20 30 100
20
10 50
10
0 0 0
US GPM 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800
CAPACITY
3
M /min. 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0
160
SHAFT POWER
KW BHP
110
140
100
90 120
W ER
T PO
80 S HAF
100
70
60 80
Jan. 13 DM-LH-05
LH - SERIES
TSURUMI PUMP DEWATERING PUMPS DIMENSIONS
LH6110-61
LH8110-61
D
6” JIS20K (300PSI) Flange
A1
for LH6110
8” JIS10K (150PSI) Flange A
for LH8110
with 6” or 8” NPT Companion Flange As
Metric M12x1.75 Tap
8 holes for Lifting Lug
(2.756")
70mm
100mm
(3.937")
Air Tightness
Check Plug
B
(33.46")
850mm
B1
100mm
(3.937")
(2.756")
70mm
C.W.L.
W1
C.W.L. : Continuous running Water Level
DIMENSIONS:USCS (I nch)
Model HP NOM. Pump & Motor C.W.L. Wt.
SIZE A As A1 B B1 D W1 (lbs.)
LH6110-61 150 6" 23 7/16 24 1/2 11 13/16 74 5/16 58 7/16 23 5/16 7 7/8 2670
LH8110-61 150 8" 23 7/16 24 1/2 11 13/16 74 5/16 58 7/16 23 5/16 7 7/8 2670
DIMENSIONS:ME TRIC (mm)
Model kW NOM. Pump & Motor C.W.L. Wt.
SIZE A As A1 B B1 D W1 (kg)
LH6110-61 110 150 596 622 300 1887 1485 592 200 1210
LH8110-61 110 200 596 622 300 1887 1485 592 200 1210
Jan. 13 SEC-LH-06
LH - SERIES
TSURUMI PUMP DEWATERING PUMPS SECTIONAL VIEW
48
LH6110-61
LH8110-61
37 1
72
50 6
53 52A
64 55
65 56
52B 26A
25 54
30 60
90 36
71A 71B
35 26B
29 21
20A 34
20B 23
43
ITEM# DESCRIPTION MAIN MATE RIAL / NOTE RELATED ASTM, AISI CODE RELATED EN CODE Q'TY
1 Power Cable Chloroprene Sheath AWG 1/3, 4/1, 14/3 -65ft 1
Power Cable Chloroprene Sheath AWG 1/3 -65ft 1
6 Stuffing Box Cast Iron A48M Class30B EN 1561 GJL-200 2
20A Upper Pump Casing Cast Iron A48M Class30B EN 1561 GJL-200 1
20B Lower Pump Casing Ductile Cast Iron A536 100-70-03 EN 1563 GJS-700-2 1
21 Impeller High Chrome Cast Iron A532 Class III Type A DIN 1695 G-X260Cr27 1
23 Suction Strainer Steel (Cold Rolled) A109/A1008 EN 10130 1
25 Mechanical Seal Silicon Carbide / H-50T 1
26A Oil Seal Nitrile Butadiene Rubber / SC-507210 1
26B Labyrinth Ring Stainless Steel S 40300 1.4000 1
29 Oil Casing Cast Iron A48M Class30B EN 1561 GJL-200 1
30 Oil Lifter Steel (Cold Rolled) A109/A1008 EN 10130 1
34 Suction Mouth High Chrome Cast Iron A532 Class III Type A DIN 1695 G-X260Cr27 1
35 Oil Plug Stainless Steel S 30400 1.4301 2
36 Lubricant Turbine Oil ISO VG32 or SAE10W-20
37 Flanged Discharge Pipe Ductile Cast Iron / 6" JIS20K or 8" JIS 10K A536 100-70-03 EN 1563 GJS-700-2 1
43 Cathodic Protection Plate Aluminium Alloy 3
48 Companion Flange Cast Iron / NPT 6"or 8" A48M Class30B EN 1561 GJL-200 1
50 Motor Head Cover Cast Iron A48M Class30B EN 1561 GJL-200 1
52A Upper Bearing #NU312ECM 1
52B Lower Bearing #7313BECBMDB w/ Spacer 1 set
53 Motor Protector 3
54 Shaft Stainless Steel S 42000 1.4028 1
55 Rotor 1
56 Stator 1
60 Bearing Housing Cast Iron A48M Class30B EN 1561 GJL-200 1
64 Motor Housing Cast Iron A48M Class30B EN 1561 GJL-200 1
65 Outer Cover Steel A283 Grade D EN 10025 S275 1
71A Shaft Sleeve (Upper) Stainless Steel S 40300 1.4000 1
71B Shaft Sleeve (Lower) Stainless Steel S 40300 1.4000 1
72 Lifting Lug Bolt Steel A283 Grade D EN 10025 S275 2
90 Leakage Sensor Electrode Stainless Steel S 30300 1.4305 1
Sep. 01 60-SS-LH-01
LH - SERIES SAMPLE
TSURUMI PUMP DEWATERING PUMPS SPECIFICATIONS
1. SCOPE OF SUPPLY -
Furnish and install TSURUMI Model ____________ Submersible Pump(s).
Each unit shall be capable of delivering _______GPM ( _______m3/min) at _______Feet ( _______m) TDH.
The pump(s) shall be designed to pump waste water or effluent without damage during operation. The pump(s)
shall be designed so that the shaft power required (BHP)/(kW) shall not exceed the motor rated output
throughout the entire operating range of the pump performance curve. Pump(s) shall be of the top discharge,
flow through design.
2. MATERIALS OF CONSTRUCTION -
Construction of major parts of the pumping unit(s) shall be gray cast iron, ASTM A48 CLASS 35. Impellers and
field adjustable/replaceable wear plates shall be high chrome iron. Internal and external surfaces coming into
contact with the pumpage shall be protected by a fused polymer coating. All exposed fasteners shall be
stainless steel. All units up to 75 HP and LH875/890/8110 shall be furnished with 150 lb. (10 kg/cm2) flat face
flange and NPT companion flange. LH675/690/6110 shall be furnished with 300 lb. (20 kg/cm2) flat face flange
and NPT companion flange. Impellers shall be of the multi-vane enclosed solids handling design equipped
with back pump out vanes and shall be slip fit to the shaft and key driven. The unit(s) shall include built in
cathodic protection.
3. MECHANICAL SEAL -
All units shall be furnished with a dual inside mechanical shaft seal located completely out of the pumpage,
running in a separate oil filled chamber and further protected by an exclusionary oil seal located between the
bottom seal faces and the fluid being pumped. The oil chamber shall be fitted with a device that shall provide
positive lubrication of the top mechanical seal, (down to one third of the standard oil level). The device shall not
consume any additional electrical power. Mechanical seals shall be rated to preclude the incursion of water up to
42.6 PSI (98.4 Ft.) submergence. Units shall have silicon carbide mechanical seal faces. Mechanical seal
hardware shall be stainless steel. Unit(s) shall incorporate seal pressure relief ports. Units 75 Hp and above
shall be supplied with electrode type seal sensor. All unit(s) shall be fitted with a replaceable shaft sleeve.
4. MOTOR-
The pump motor(s) shall be ______H P., ______kW., ______V., 60 Hz. 3 Phase and shall be NEMA MG-1,
Design Type B equivalent. Motor(s) shall be rated at full load amps. Motor(s) shall have a 1.15 service factor
and shall be rated for 20 starts per hour. Motor(s) shall be air filled, copper wound, class F or B (up to 30 HP)
insulated with built in thermal protection for each winding. Motor shaft shall be 420 stainless steel and shall be
supported by two high temperature bearings, with a B-10 life rating at best efficiency point of 60,000 hours.
On units up to 60 HP, the bottom bearing shall be two row, double shielded, C3, deep groove type ball bearing,
and the top bearing shall be single row, double shielded, C3, deep groove type ball bearing. On units 75 HP
and above, the bottom bearing shall be re-greasable, two row, C3, angular contact type ball bearing, and the
top bearing shall be re-greasable, single row, C3, cylindrical roller bearing. Motors shall be D.O.L. or star-
delta start (40 HP and above), and shall be suitable for across the line start or variable speed applications,
utilizing a properly sized variable frequency drive.
5. POWER CABLE AND CABLE ENTRANCE -
The pump power cable shall be suitable for submersible pump applications and shall be field replaceable utilizing
standard submersible pump cable. The cable entrance shall incorporate built in strain relief and a combination
three way mechanical compression sealing. The cable entrance assembly shall contain a anti-wicking block to
eliminate water incursion into the motor due to capillary wicking should the power cable be accidentally damaged.