POWER YOUR FUTURE                                                 AP80S** YTO
YTO Generator                                              Prime Power: 72 KW/90KVA
    AP80S** YTO                                           Standby Power: 80 KW/100KVA
                                                      GENERATING POWER SOLUTIONS
                                                        Increased availability for new operations
                                                        Reliable, robust and versatile generator.
                                                        Ready to deliver power for a next job.
                                                        Increased uptime during operations
                                                        Once installed on the end-user-site, the
                                                        generator will be ready to run: “peace of
                                                         mind” operation.
                                                        Reduced transport and installation costs
                                                        The compact and robust design with integrated
                                                        transport features enables faster and safer
                                                        transport and installation.
                                                        Reduced service & maintenance costs
                                                        Longer service intervals.
                                                        Quicker and more efficient service jobs.
                                                        Premium resale value
                                                        Designed and built to last.
YTO Series
35KVA--400KVA
Technical Data                                                                                   AP80S** YTO
Model                                 AP80S** YTO     Alternator
Rated prime power              kva    72kw (90kva)    Model                     Type Stamford       LK224F
Rated stand by power           kva   80 kw (100kva)
Rated voltage line to line      V       220/127       Phase                                           3
Rated current                   A         264         Voltage                          V          220/127
Maximun sound level          dB(@7m)      ≤85         Wiring Type                         3 Phase 4 wire, Y type
                                                      Bearing                                         1
Engine-YTO                                            Power factor                                   0.8
Model                                  LR4M3L-18      Frequency                        Hz            60
Air intake system                     Turbocharged    Prime power                     KVA            94
Fuel injection system                            Direct Inject   Exciter Type                       Brushless, self-excitation
No. cylinders                                          4         Voltage regulation                %              ±0.5
Displacement                          Liquid         4.75        Protection Grade                                IP 23
Bore*Stroke                            mm         110*125        Insulation grade                                  H/H
Compression ratio                                     17         Altitude                          m             ≤1000
Rated speed                           r/min         1800         Controller-DEEPSEA
Rated net power(with fan)              Kw              0         Model                                           DSE6120
Governor type                                     Electronic     Protective functions:
Start Motor                             V             24          Low oil pressure
                                                                  High water temperature
Exhause System                                                    High/low voltage
Exhause gas flow                      m³/min           /          High Engine Temperature and Overspeed.
Exhause gas temp                        ℃              /          Voltage regulator frequency regulator
Max back pressure                      kPa            ≤6          Emergency stop
                                                                  Start failure
Air Intake System
Max inlet restriction                  kPa            ≤5
Consumption                           m³/min           /
Air flow                              m³/min           /
Fuel System
100% load(Prime power)                 L/h           22.5
75% load(Prime power)                  L/h           16.8
50% load(Prime power)                  L/h           11.3        Control Module Options
Fuel tank capacity                      L            260
Lubrication System
Total system oil capacity               L           14
Oil temperature maximum to bearings    ℃            115
Min oil pressure                       kPa        294-490
 (Governed Speed)                                                 Auto generator control module
                                                                  Control module with" Three Remote Control" functions
Cooling System                                                    ATS auto load transfer screen
Total coolant capacity                  L             6           Synchronising control modules
Thermostat                              ℃           76-95         Power output cabinet
Max top tank temperature                ℃            99
Standard Features                                                Unit Dimensions(Basic unit)
Engine (YTO)                                                 ●
Radiator 50°C max,fans are driven by belt                    ●
24V charge alternator                                        ●
Alternator: single bearing alternator IP23,
insulation class H/H                                         ●
Standard auto control system                                 ●
One set of air filter, fuel filter, oil filter               ●
Main line circuit breaker/MCCB                               ●
Base fuel tank                                               ●
Two 12V batteries, rac and cable                             ●
Exhaust system(Ripple flex exhaust pipe,                                                  Open Type
 exhaust siphon, flange, muffler                             ●            L*W*H                 mm           2200*900*1450
User manual                                                  ●            Weight                 kg              1100
Options
Battery charge                                    ○
Engine heater                                     ○
Alternator heater                                 ○
PMG                                               ○
Water oil separator                               ○
Daily fuel tank                                   ○
Remote control panel                              ○
Automatic transfer switch/ATS                     ○
Switch box                                        ○                      Silent Type
Standard: ●                Options:○                       L*W*H                 mm      2870*1050*1550
                                                           Weight                 kg          1500
Warranty*
YTO Engine
12 months from date of purchase and 1000 hours.
Generator
12 months from date of purchase or 1000 hours
(whichever occurs first).
                                                                        Trailer Option
                                                            L*W*H                mm      4200*1900*950
                                                      Max loading weight          kg         1650