0% found this document useful (0 votes)
52 views1 page

Top Level Enlarged View - 10 4: REFER TO SHEET DG-PIN-473-0000-FEM-SDW-FP-200-2214003

Uploaded by

azarmech2013
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views1 page

Top Level Enlarged View - 10 4: REFER TO SHEET DG-PIN-473-0000-FEM-SDW-FP-200-2214003

Uploaded by

azarmech2013
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Copyright by the Diriyah Gate Development Authority (DGDA). All rights reserved.

This document may not,


in whole or in part, be reproduced, stored, transmitted or distributed in any form or by any means, whether
electronic, mechanical, by photocopy, recording or otherwise, without the prior written permission of
DGDA. Except where otherwise expressly agreed in writing by DGDA, DGDA shall have no responsibility or
liability for any loss (direct, consequential or otherwise) which may arise from reliance on or use of this
1500 document or the information contained therein.

DO NOT SCALE THIS DRAWING.

KEY PLAN : NORTH

F.F.P ∅25 mm
C.O.P : 643.880

N
1305
Q

40
MC3
0

SIDE WALL SPRINKLER


E191

C.O.P : 660.725
F.F.P ∅25 mm

MISSING IN IFC ARE PROVIDED


DRAIN & SPRINKLERS PIPES
4000

8000
Q ORIENTATION DATUM
JH comment: N

CO
OP
P:
:4
60
4.
35
.
62
5
0
Provide additional extinguishers as the travel
GEODETIC DATUM: WGS-84
distance exceeds the limit for a Class A Hazard

5
PROJECT SYSTEM: UTM
as per NFPA 10, clause 6.2.1. ZONE: 38N
[K Mahmoud/M Aleem 16-April-2025]
Mecca
F.F.P
BOP: C.O. ∅65 mm
644.4 P:6 0 5 000 10 000
8 44.18
5
N T
C.O.N-U - T-B R01 F.F.P
C.OP.PU : 64-B R C.O. ∅50 mm 1 : 100
: 644.40512

1540
4 P:6 Q

1705

555
4
3000
.452 BOP:6 3.880 GENERAL NOTES

295
REFER TO SHEET DG-PIN-473-0000-FEM-SDW-FP-200-2214003

1815
TYPI 43.73

3000

2000
C
SUP AL BRA

C.O. ∅25 mm
0
F.D.R

43.88
POR N

C
O
P
:
6
4
3
.
6
8
3
485
T SP CH

C
O
P
:
6
4
0
.
5
5
6
1. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH OTHER DISCIPLINES.

261
∅20

E013
0
ACIN

6
mm

MC3
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

643.7
G

C.O. ∅25 mm
4000

2010
F.F.P

= 38
3. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

P:6

43.88
C.O. ∅50 mm

6
NN-U-U 4. ALL DEVIATIONS FROM DESIGN DRAWING DUE TO COORDINATION WITH

F.F.P

643.7
0.50%

m
CC T- R P:6
.P.P: 6TB-B

BOP:
.O.O

FEC
01 OTHER TRADES.

C.O. ∅25 mm
R 4

4000 880
: 464.44601 BOP:63.880 F.F.P

1.98
P:6
5. ALL LEVELS ARE TAKEN FROM SURVEY LEVEL +0.00
.4767 43.73 C.O. ∅40 mm T/A

BOP:

43.
m 6. ANCHOR AND GUIDED SUPPORTS USED BEFORE AND AFTER EXPANSION

F.F.P
P
18.37 3/4"

EXT
3030 BOP:6: 643.880 BALL

C.O. ∅25 mm
0
BOP:6

3000
JOINTS AND ON ELBOWS ARE TO BE UPDATED IN FURTHER REVISIONS

P:6
N

43.88
EJ 2 44.49 43.72 VALV INCLUDING PIPE STRESS ANALYSIS STUDY.
E

TO N
F.F.P

.F.P
0MM Q

5
3480

2040

643.7
2050

C.O. ∅25 mm
25 m 5

0
C.O.

2000

P:6
m

43.88
P

43.75 F
BOP:6: 644.46 1610 FIRE FIGHTING LEGEND

4
E
FP-200-2214004

F.F.P

643.7
44.49 2 3480

BOP:
ANC
C-A F.F.P CONTROL VALVE WITH SUPERVISORY

C
NC

P:6

m
∅25 JH comment: SWITCH

C 4
O .
P 1
:
6
4
3
.
8
8
1
2005

C-AN
Q mm

BOP:
F.F.P
DIST
Sidewall sprinklers coverage is inadequate. Maximum

3.95
3800 3480 SHA

BOP:
FT O SIGHT GLASS

C
O
P
:
6
4
2
7
distance between standard coverage sidewall
PEN

3000

2000
2700 ING sprinklers and between sprinklers and walls shall be as
260

2165
3480 per NFPA 13, table 10.3.3.2.1. PRESSURE GAUGE
475
4 TOP LEVEL ENLARGED VIEW - 10

C
O
P
:
6
4
4
.
2
2
7
6 mm
Contractor shall select extended coverage sidewall

C
5 sprinklers to comply with coverage requirements.

C-AN
. B 4

FEC 29 1.18
BOP:644.50 EXPA FP-200-2214004 [K Mahmoud/M Aleem 16-April-2025] FLOW SWITCH
NSIO
1 -UT-
N NJ OINT SCALE: 1 : 50

m
C.O.P BR PENDENT SPRINKLER HEAD 1/2inch -NTP -K-Factor
: 644 01 5.6gmp/psi1/2 – 68o C

1.98
3000 .497 C
THER
MAL E SPR UPRIGHT SPRINKLER HEAD 1/2inch -NTP -K-Factor
TYP

C
O
P
:
6
4
3
.
8
9
6

E013
0
J
MISS INKLERS

3000
ICAL

MC3
5.6gpm/psi1/2 – 68o C
SUP
POR BRANCH ING I &
N IFC DRAIN SIDE WALL SPRINKLER HEAD 1/2inch -NTP -K-Factor
T SP ARE PIP
ACIN MC3 PRO ES 5.6gpm/psi1/2 – 68o C
G 0 VIDE
E191 D
N- 1730 GATE VALVE
C.O.PUT-BR01 1725

FEC
: 644
BOP:6 .512 BALL VALVE
44.52 1100 OS&Y VALVE WITH TAMPER
F.F.P ∅100 mm

3000
SWITCH SWING CHECK VALVE (WATER HAMMER CONTROL)
F.F.P ∅100 mm PRESSURE GAUGE
F.F.P ∅350 mm SPRINKLER CLAMP FLOW SWITCH SIAMESE FIRE DEPARTMENT CONNECTION
(FREE STANDING)
F.F.P ∅350 mm
N-
C.O.PUT-BR01 SLOPE : 0.50% FLEXIBLE COUPLING
: 644
.527
BOP:6 F.F.P ∅100 mm F.F.P ∅80 mm RIGID COUPLING
44.53

3000

765

215
SLOPE : 0.50% B

300
1230

355
B 400 200 ABC DRY CHEMICAL PORTABLE FIRE EXTINGUISHER ( 9 K.G )
2 M
1

FP-200-2214004 CO2 CO PORTABLE FIRE EXTINGUISHER


7840

N-
C.O.PUT-BR01

TS
140

F.F.P ∅80 mm

SUP ING
POR
: 644 FHO/3 CLASS III FIRE HOSE REEL (HOSE REEL LENGTH = 30 METERS)

AC
.542
HO=

= 40

2500
BOP:6 1100

BETW AL SP
44.55 (TYPE FP-A): DN350 FIRE SUPPRESION PIPING SUPPORT TYPE:
3000

EEN
FEC
XT F

TRAPEZE WITH THREADED ROD

TYPIC
1725 L (TYPE FP-B): DN350 FIRE SUPPRESION PIPING SUPPORT

4500
O NE

EXT

TYPE: TRAPEZE RIGID SUPPORT

4200
DN125 AND SMALLER FIRE SUPPRESION PIPING SUPPORT TYPE:

3735
TO N

N-
C.O.PUT-BR01
ET

SPRINKLER CLAMP

TS

3270
SUP ING
: 644

POR
ANC

.557 FHO/3 DN150 FIRE SUPPRESION PIPING SUPPORT TYPE: CLEVIS HANGER

AC
BOP:6
E

3000
44.57
ANC

BETW ICAL SP
3000
DIST

F.F.P ∅65 mm

EEN
L FLOW DIRECTION
DIST

TYP
FIRE EXTINGUISHER CABINET

T
.
O
.
C
+
6
4
0
.
6
5
9

T
.
O
.
C
+
6
4
0
.
6
5
4
ABBREVIATIONS

900
N-
C.O.PUT-BR01 F.F.P FIREFIGHTING PIPE
: 644
.572
BOP:6 C.O.P CENTER OF PIPE
44.58
3000

Z.C.V ZONE CONTROL VALVE

F.D.R FIRE DRAIN PIPE


BOP:64
4.59 N- 8000 T.O.C TOP OF CONCRETE
C.O.PUT-BR01
: 644 F.H.O FIRE HOSE CABINET
.587
3000
TYP
3 SECTION DETAIL FOR FIRE HOSE CABINET
3000

IC F.E.C FIRE EXTINGUISHER CABINET


SUP AL BRA
POR
T SP NCH
ACIN SCALE: 1 : 50
G ENGINEERING DOCUMENT REVIEW
A
N-
C.O.PUT-BR01
Disclaimer: By the Consultants review status indicated herein, the Contractor shall not be relieved of
responsibilty for any deviation from the requirements of the contract documents, unless the
: 644 Contractor has specifically informed the Consultant of such deviation in writing at the time of
.602
BOP:6 1500 submission, The contactor shall not be relieved from responsibilty for errors, omissions or
44.62 SPRINKLER CLAMP
3000

uncoordinated information in the submission or non-compliance with the Contract Documents and
150 Applicable Laws. The recipient is responsible to ensure the contents of this disclaimer are understood

150
by personnel in their organization.

1300
Q
N-
C.O.PUT-BR01 SIDE WALL SPRINKLER
□ A. Approved □ B. Approved with comments
: 644 SPRINKLERS & DRAIN PIPES
.617
BOP:6
44.63 MISSING IN IFC ARE PROVIDED
N □ C. Review and Submit □ D. Rejected

7500
3000

REVIEWED BY DISCIPLINE REVIEWED BY: DATE


Name:
N- Architectural / Civil
C.O.PUT-BR01 Signed:

16770
: 644 N Name:
.632
BOP:6 Electrical
44.65 Signed:

7500
3000

Name:
SPRINKLER CLAMP UPRIGHT SRPINKLER Samiyudeen J 20-04-2025
Mechanical
Signed:

100
N ENGINEER Ayman Indrawes / Sherif Eissa Date
N-
C.O.PUT-BR01

765
Signed

1220
: 644 135
.647
BOP:6

560
44.65 F.F.P ∅25 mm
3000

120
65
F.F.P ∅50 mm F.F.P ∅50 mm F.F.P ∅40 mm

C
O
P
:
6
4
3
.
6
8
3
C
O
P
:
6
4
3
.
6
5
0
F.D.R ∅20 mm

F.F.P ∅100 mm
F.D.R ∅20 mm

F.F.P ∅65 mm

100
350
F.F.P ∅350 mm
3480 3480 3480 3480 0.50%
N-
C.O.PUT-BR01
: 643 1100
.698 00 ISSUED FOR APPROVAL 13-APR-2025

3735
BOP:6

3/4" BALL VALVE


4500
44.68
E012
0

3000

REV DESCRIPTION APRV CHK'D DATE

4140
MC3

SPRINKLER CLAMP

3800
1725 DRAWING REVISIONS

3200
3450

3030
3280
1710
A F.D.R ∅20 mm CLIENT
N-
C.O.PUT-BR01 DIRIYAH COMPANY
: 643
.713
BOP:6
0

44.69
3000
275

T
.
O
.
C
+
6
4
0
.
5
2
3
C
O
P
:
6
4
4
.
4
2
9

C
O
P
:
6
4
0
.
5
8
9
EJ 2
0MM
C

C
O
P
:
6
4
4
.
0
9
4

7747 UMRO ADHAMRY STREET,


C-AN

DIPLOMATIC QUARTER
210 UNIT #2, RIYADH 12512,
C

200 KINGDOM OF SAUDI ARABIA


10450

C-AN

WWW.DGDA.GOV.SA
F.F.P
46

C.O. ∅25 mmC-AN


0
3000

C
O
P
:
6
4
4
.
4
3
8

P:6
303

44.6 C EXPANSION JOINT PROGRAMME MANAGEMENT CONSULTANT


BOP:6 84
44.71
3 3800 5 SHAFT SECTION DETAIL-02
B

SAUDI ARABIAN PARSONS LIMITED


C-AN

RIYADH P.O BOX 11431


FP-200-2214004 475 PHONE: +966 1 2884016
N-UT THERMAL EJ SCALE: 1 : 50
C
O
P
:
6
4
4
.
1
0
8

FAX: +966 1 2172134


C.O.P -BR01
E012
0
MC3

: 643
.743
BOP:6
3000 3

LEAD DESIGN CONSULTANT - CONSTRUCTION SUPERVISION CONSULTANT


44.73
/

C
FHO

F.F.P F.F.P ∅100 mm PO BOX 58729 TAWUNIYA TOWERS SOUTH


C.O. ∅80 mm C.O.P : 644.900
F.F.P ∅100 mm
TOWER MEZZANINE FLOOR KING FAHAD ROAD
P:6 RIYADH, 11414 KINGDOM OF SAUDI ARABIA
44.90 T: +966 1 200 8160
0 UPRIGHT SRPINKLER SPRINKLER CLAMP F.F.P ∅350 mm WWW.AECOM.COM
N-UT
C.O.P -BR01
: 643 MEP AND FITOUT CONTRACTOR
.758 1080
BOP:6

205
TYPI 44 . 1100
3000

C 75

470
PO BOX 58621 MUSA IBN NUSAIR STREET
SUP AL BRA

150

765
POR RIYADH, 11515, KINGDOM OF SAUDI ARABIA
N
T SP CH 169 REFER TO SHEET DG-PIN-473-0000-FEM-SDW-FP-200-2214005 T: +966 11 465 9560

1205
17250
ACIN F.F.P ∅350 mm WWW.FEMCO.COM.SA
G 3000
SLOPE : 0.50%
N- TYPICAL BRANCH SUPPORT SPACING
C.O.PUT-BR01 PROJECT TITLE
: 643
.773 F.F.P ∅100 mm A North and South Spines & Utilities –Tunnels –MEP and Tunnel Fit-Out
SLOPE : 0.50% 2000 4000 275 1100 (Package-C) - DD-2022-212
TYPICAL BRANCH SPRINKLER SPACING
1725 PROJECT ADDRESS: AD DIRIYAH, RIYADH, KINGDOM OF SAUDI ARABIA
4500

4030
DRAWING TITLE

3735
NORTH SPINE-UTILITY TUNNEL-TUNNEL

3290
03-FIRE FIGHTING-PLANS- PART 4 OF 6
T
.
O
.
C
+
6
4
0
.
4
9
5

T
.
O
.
C
+
6
4
0
.
4
9
4
PURPOSE OF ISSUE DISCIPLINE SEAL DATE

ISSUED FOR APPROVAL MECH 13-APR-2025

PREPARED BY: CHECKED BY: REVIEWED BY: APPROVED BY:


A.Dawood C.Kadioglu R.Serrano E.Kaymaz
8000
MODEL FILE REF SCALE A0 (841x1189) REVISION NO

1 NORTH SPINE-UTILITY TUNNEL-TUNNEL03-FIRE FIGHTING-PLANS - PART 4 OF 6 2 TYPICAL SECTION DETAIL FOR FIRE BRANCH (N-UT-BR01) DG-PIN-473-0000-FEM-DDE-FP-A00-2214000-00
1:100/1:50 00
SCALE: 1 : 100
SCALE: 1 : 50 DRAWING NUMBER

DG-PIN-473-0000-FEM-SDW- FP-200-2214004

You might also like