TYPICAL DESIGN CALCULATION FOR BRIDGE MAST BASE PLATE & HOLDING DOWN BOLTS
ON BRIDGE NO-29 BRIDGE MAST (BM-200)
                                                                     MAST CALCULATION
Legend:-                                       Description                               Unit              Factor                       Remarks
      1        Safety Factor for wire                                                   kg/m                0.75          Sw
      2        Safety Factor for mast                                                               kg/m        1.9       Sm
               Basic Data
               Weight of OHE                                                                        kg/m        1.6
               Weight of Bracket Assembly                                                            kg         60        Wbkt
               Weight of Man                                                                         kg         60        Wman
               Tension in Each Conductor                                                             kgf       1000       Tohe
               Dia of Catenary wire                                                                   m      0.01054      Dcat
               Dia of Contact                                                                         m      0.01224      Dcon
               Spans
               At "A"                                                                               m           38.2      L1
               At "B"                                                                               m           26.2      L2
               Basic wind Pressure                                                                kgf/m2        178                 IS875:PART-3
  S.No                                           Description                                       Unit     Calculation                Reference
  1            Type Of Mast                                                                                   B-200
           A   Length Of Mast                                                                         m        11.50      Lm
               Unit Weight of Mast                                                                 Kg/M       61.20
  2            Total Weight of Mast                                                                 m         703.80      Wmast
           B   Additional Height of Super Mast                                                        m        0.00       Lsm
               Total A+B                                                                              m       11.50       Ltotal
           C   Intensity Of wind                                                                   kg/m2      178.00      Wp
           D   Depth Of construction(Pier top to Rail Level)                                          m        3.42       Dcons
           E   Height of contact wire from Rail Level                                                 m        5.50       Hcon
           F   Height of contact wire from base plate                                                 m       8.920       Hcon-bp= Dcons+Hcon
           G   Encumbrance                                                                                     2.000      E
           H   Height of catenary wire from base plate                                                m       10.920      Hcat-bp= Hcon-bp + E
           J   Distance of Contact wire from mast C.L (Imp.)                                          m        3.55       Imp
  3            OHE Span on either side of Mast
                                                                             Average Span C           m       32.20       (L1+L2/2)
  4            Degree Of curve                                                                                 0.00
  5            Radial Pull (Due to Staggering ) Contact wire
                                                                                    Stagger A        m        0.20        a
                                                                                    Stagger B        m        -0.20       b
                                                                                    Stagger c        m        0.20        c
                                                        ((StaggerA+StaggerB)/Ave. Span)x1000         kg       12.42       [(a+c)*AVERAGE
                                                                                                                          SPAN*T/1000
                                                                                         Say         kg       12.00
  6            VERTICAL LOAD
           A   Weight of OHE(Average Span x Weight of OHE)                                           kg        51.52      Wohe
           B   Weight of Bracket                                                                     kg        60.00      Wbkt
           C   Weight of man on the Bracket                                                          Kg        60.00      Wman
           D   Weight of mast                                                                        kg       703.80      Wmast
           E   Weight of super mast@40kg/m                                                           kg        0.00       Wsm
           F   Weight of super mast cantilever arm                                                   kg        0.00       Wsm-ca
           G   Weight of RC Wire                                                                     kg        0.00       Wrc
           H   Weight of Base plate (0.7x0.7x0.025x7850*2)                                           kg       264.94      Wbp
               TOTAL VERTICAL LOAD (A+B+C+D+E+F+G+H)                                                 kg      1140.26      Wtotal
                                                                 TOTAL VERTICAL LOAD Say             kg      1140.00      Wtotal
                            MAYURE          Digitally signed                             Digitally signed
                                            by MAYURESH                   ZAHID byAKHTAR
                                                                                    ZAHID
                            SH              KUMAR
                            KUMAR
                                            Date: 2025.09.02
                                            14:48:32 +05'30'
                                                                          AKHTAR 14:48:43
                                                                                 Date: 2025.09.02
                                                                                          +05'30'
7       WIND LOAD
    A   On catenary wire(Including 5% wind load on dropper
        0.75x Dia of catenary wire x wp xAvg span x1.05                                kg    47.57
    B   On Contact wire(Including 5% wind load on dropper
        0.75x Dia of contact wire x WP xAvg span x1.05                                 Kg    55.25
    C   On RC wire                                                                     kg    0.00
    D   On Bracket                                                                     kg    40.00
    E   On mast and super mast                                                         kg    0.00
    F   Wind load on mast (0.2xWpxLmxsafety factor for mast)                           kg   777.86
8   A   VERTICAL LOAD AND BENDING MOMENT
        Weight
    1   Weight of man                                                                  kg     60.00
    2   Weight of Bracket                                                              kg     60.00
    3   Weight of OHE (Avg span x Weight of OHE)                                       kg     51.52
    4   Weight of mast                                                                 kg    703.80
    5   Weight of super mast                                                           kg     0.00
    6   Weight of super mast cantilever                                                kg     0.00
    7   Weight of RC Wire                                                              kg     0.00
    8   Weight of Base plate                                                           kg    264.94
                                                               TOTAL WEIGHT            kg   1140.00   Fcom
        LEVER ARM
    1   Distance of Contact wire from mast C.L (Imp.)                                  m     3.55
    2   Distance of Contact wire from mast C.L (Imp.)/2                                m     1.78
    3   Distance of Contact wire from mast C.L (Imp.)                                  m     3.55
        MOMENT
    1   man                                                                          Kg-m   213.00
    2   Bracket                                                                      Kg-m   106.50
    3   OHE                                                                          Kg-m   182.90
    4   mast                                                                         Kg-m    0.00
    5   super mast                                                                   Kg-m    0.00
    6   super mast cantilever                                                        Kg-m    0.00
    7   RC Wire                                                                      Kg-m    0.00
    8   Base plate                                                                   Kg-m    0.00
                                                               TOTAL WEIGHT          kg-m   502.40
    B   HORIZONTAL FORCES AND MOMENTS(PERPENDICULAR
        TO TRACK)
        Weight
    1   Wind load on catenary wire                                                     kg    47.57
    2   Wind load on contact wire                                                      kg    55.25
    3   Wind load on mast                                                              kg   777.86
    4   Wind on Radial pull contact                                                    kg    12.00
    5   RC
        LEVER ARM
    1    catenary wire                                                                 m     10.92
    2    contact wire                                                                  m     8.92
    3    mast= (Lmast/2)                                                               m     5.75
    4   Wind on Radial pull contact                                                    m     8.92
    5   RC                                                                             m
        MOMENT
    1   Wind load on catenary wire=                                                  Kg-m    519.50
    2   Wind load on contact wire=                                                   Kg-m    492.80
    3   Wind load on mast=                                                           Kg-m   4472.70
    4   Wind on Radial pull contact                                                  Kg-m    107.04
    5   RC                                                                           Kg-m     0.00
                                                                     TOTAL           kg-m   5592.04
                 MAYURES Digitally signed by
                         MAYURESH KUMAR                    ZAHID      Digitally signed by
                                                                      ZAHID AKHTAR
                 H KUMAR Date: 2025.09.02
                         14:48:55 +05'30'
                                                           AKHTAR     Date: 2025.09.02
                                                                      14:49:05 +05'30'
9    TOTAL BENDING MOMENT(Perpendicular to the track)=                                kg-m              6094.44
     (total weight + total moment)
     Parallel to track =5% of perpendicular to track bending                            kg               304.72
     moment
                                                                               Say     kg               297.00
     Moment at X-X,=(0.75xFcom+moment perpendiculat to track)                         Kg-m              6949.44   Mxx
                                    B.HOLDING DOWN BOLT CALCULATION
     moment at XX,M(0.75xFcom+moment perpendiculat to track)                          Kg-m              6949.44   Mxx
                                                                                      kg-cm             694944
     Compressive Force on column                                                        kg              1140.00   Fcom
     Lever arm (Spacing between tow different end Bolt )                               cm                50.00    Lspacing
     Force in Bolt=                                                                     kg             13898.88   F=Mxx/Lspacingx100
     Using no of bolt on oneside                                                       Nos               3.00
                                                                          Both side    Nos               6.00
     Axial compression forcein one bolt=                                                kg              190.00    Faxial= Fcom/no. of bolt
                                                                                                                  both side
     Force in each bolt=                                                                kg              4442.96   Fbolt= F/3-Faxial
                                                                               Say      kg              4443.00
     Permissible tension in each bolt                                                 kg/cm2            1224.00   As per RDSO Guideline for
                                                                                                                  Bridge mast calculation
     Area required =                                                                   cm2                3.63    Fbolt/1224
     Provided diameter of holding down bolt                                            mm                25.00    Dbolt
                                                                                                                  As per RDSO Guideline for
     Provided area                                                                     cm2                4.91    Bridge mast
                                                                                                                  calculation
     is diameter of bolt safe(provided are >required area) or unsafe                                      safe
     Embedded Length of Bolt(Design bond stress; M-20 As per 26.2.1 of IS              cm                52.22    As per RDSO Guideline for
     456:2000-8.15kg/cm2)= Fbolt/(1.33x8.15xdia. of boltx3.14)                                                    Bridge mast calculation
     (Permitted stress increased by 331/3% when wind load is
     considered as per annexure B 2.3,IS456:200)
     (Length of bolt extended by thickness of base plate=2.5cm,Depth of                cm
     channel=0cm and extra margin                                                                        69.72
     15cm)
     provided length                                                                   cm                  85     safe
                                             C.DESIGN OF BASE PLATE CALCULATION
     Max. Tension in each Bolt                                                          kg              4443.00   Fbolt
     Bending moment at critical section X-X= 3xFboltX length of mast                   kg-m              25325    Mcritical
     Permissible bending stress in plate(1650x1.33)                                   kg/cm2            2195.00   As per RDSO Guideline for
                                                                                                                  Bridge mast calculation
     Thickness required=Bt2/6xfb=DM at critical section X-X =suare root                cm                 0.99
     [(Mcriticalxno. of bolt)/(2195xwidth of base plate)]
                                                                                    cm                     0.99
     Thickness required                                                             mm                     9.90
     Thickness provided                                                             mm                    25.00   safe
     Provide 25 mm thick Base Plate.
     Hence Base Plate Size is 700mmx700mmx25mm
      Note :Calculation is done, based on the reference of RDSO Guidelines Manual for Bridge mast.(June 2022)
     page 17-23
                       Digitally signed by
    MAYURES MAYURESH                                  ZAHID Digitally signed by
                                                             ZAHID AKHTAR
            KUMAR
                                                      AKHTAR 14:49:39 +05'30'
                                                             Date: 2025.09.02
    H KUMAR Date: 2025.09.02
            14:49:29 +05'30'