ASMTower 2018.4               Job No.     40m Guyed Pole       Rev. No.
A
                              Client      OG                   Date          5/11/2017
                              Project     GSM Network          Designed by   M.Joe
                                                               Checked by    A.S.M
ASMTower 2018.4
                                        Structure Design For
                                          40m Guyed Pole
                                              Client: OG
                                        Project: GSM Network
    A             5/11/2017                   First issue      M.Joe           A.S.M
   Rev.             Date                     Description    Designed by      Reviewed by
ASMTower 2018.4              Job No.           40m Guyed Pole                        Rev. No.      A
                             Client            OG                                    Date          5/11/2017
                             Project           GSM Network                           Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
Design Basics
The design is according to ANSI/TIA-222-G-2, the following is the main design parameters:
        •      Basic wind speed is 36.11 m/s.
        •      Service wind speed is 25 m/s.
        •      Exposure category is C.
        •      Structure class is II.
        •      Topographic category is 1.
        •      Elevation at bottom of tower is 0 m.
        •      Wind directions applied on tower in the analysis are generated automatically.
        •      Wind directions applied on tower in the analysis are 0, 45, 90, 135, 180, 225, 270, 315 Deg.
        •      Wind load on each panel antenna are based on actual direction.
        •      Wind load on each microwave are based on actual direction.
Executive Summary
The structure is Safe with maximum members rating are as following:
        •      Pole parts rating is 0.32
        •      Guy wires rating is 0.55
        •      Base connection rating is 0.86
Antenna Loading Configuration
The tower is designed to carry the following:
 ID         Antenna          Elev.      Qty.     Type   Width      Thick.   Height        Mount
             Name             m                          mm         mm       mm           Name
            Quad Band
 1                            42         1       Flat    548        135      2555      Mount 76x3000
             Antenna
            Quad Band
 2                            42         1       Flat    548        135      2555      Mount 76x3000
             Antenna
            Quad Band
 3                            42         1       Flat    548        135      2555      Mount 76x3000
             Antenna
Microwave antennas
 ID            MW            Elev.      Qty.     Type   Diameter            Mount
              Name            m                           mm                Name
 1           HP 2.4m          40         1        HP     2400         Mount 114x1500
 2           HP 1.2m          44         1        HP     1200         Mount 114x1500
ASMTower 2018.4                      Job No.            40m Guyed Pole                               Rev. No.            A
                                     Client             OG                                           Date                5/11/2017
                                     Project            GSM Network                                  Designed by         M.Joe
                                                                                                     Checked by          A.S.M
ASMTower 2018.4
Pole Parts Geometry
 Part    Bottom          Top          Length        Bottom            Top        Thick.   No. Of    Bottom            Material    Weight
 No.      Elev.          Elev.          m            Diam.           Diam.        mm      Sides     Overlap            Name        kg
           m              m                           mm              mm                              m
  6        40             45                5           250           250         10      ROUND           0             A36        301.8
  5        36             40                4           250           250         10      ROUND           0             A36        241.4
  4        27             36                9           250           250         10      ROUND           0             A36        543.2
  3        18             27                9           250           250         10      ROUND           0             A36        543.2
  2         9             18                9           250           250         10      ROUND           0             A36        543.2
  1         0              9                9           250           250         10      ROUND           0             A36        543.2
                                                                     Total                                                          2716
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 0
Gust effect factor               Gh        =    0.85
Direction probability            Kd        =    0.85
Important factor                 I         =    1
Wind forces on pole parts
  Part    Wind       Mean             L         Dav           Area      tiz        Ra      C        Cf        EPA         qz     Force
  No.     slice      Elev.            m         m              m2       mm                                     m2       N/m2      KN
           No.        m
   1         1        43.5            3         0.25          0.75           0      0     10.54     0.6       0.45       927     0.35
             2           41           2         0.25          0.5            0    1.07    10.48     1.2        0.6      915.5    0.47
   2         1           38           4         0.25           1             0    1.07    10.4      1.2        1.2       901     0.92
   3         1       33.75            4.5       0.25      1.125              0    1.07    10.27     1.2       1.35      878.8    1.01
             2       29.25            4.5       0.25      1.125              0    1.07    10.11     1.2       1.35      852.7    0.98
   4         1       24.75            4.5       0.25      1.125              0    1.07    9.94      1.2       1.35      823.2    0.94
             2       20.25            4.5       0.25      1.125              0    1.07    9.73      1.2       1.35      789.2    0.91
   5         1       15.75            4.5       0.25      1.125              0    1.07    9.48      1.2       1.35      748.5    0.86
             2       11.25            4.5       0.25      1.125              0    1.07    9.15      1.2       1.35      697.3     0.8
   6         1        6.75            4.5       0.25      1.125              0    1.07    8.67      1.2       1.35      626.2    0.72
             2        2.25            4.5       0.25      1.125              0    1.07    8.32      1.2       1.35      577.5    0.66
                                                Total                                                         13.05       ---    8.62
Wind forces from transmission line clusters
   #             Elev.                Z          Ka       EPAn          EPAt      EPAa    tiz       qz         θ        Force
                  m                   m                       m2         m2        m2     mm       N/m2       Deg        KN
   1            40 To 42              41            1     0.804        0.228      0.804    0       915.5       0         0.63
   2            36 To 40              38            1     1.608        0.456      1.608    0       901         0         1.23
   3        31.5 To 36               33.75          1     1.809        0.513      1.809    0       878.8       0         1.35
   4        27 To 31.5               29.25          1     1.809        0.513      1.809    0       852.7       0         1.31
   5        22.5 To 27               24.75          1     1.809        0.513      1.809    0       823.2       0         1.27
ASMTower 2018.4                 Job No.          40m Guyed Pole                        Rev. No.      A
                                Client           OG                                    Date          5/11/2017
                                Project          GSM Network                           Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz      qz      θ      Force
                m                   m               m2      m2       m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513    1.809     0      789.2    0      1.21
   7           13.5 To 18       15.75     1        1.809   0.513    1.809     0      748.5    0      1.15
   8           9 To 13.5        11.25     1        1.809   0.513    1.809     0      697.3    0      1.07
   9            4.5 To 9        6.75      1        1.809   0.513    1.809     0      626.2    0      0.96
  10            0 To 4.5        2.25      1        1.809   0.513    1.809     0      577.5    0      0.89
                                Total                               16.884    ---     ---     ---    11.07
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41    -0.63          0     0         0      25.65       0
   2           38    -1.23          0     0         0       46.8       0
   3       33.75     -1.35          0     0         0      45.61       0
   4       29.25     -1.31          0     0         0      38.35       0
   5       24.75     -1.27          0     0         0      31.33       0
   6       20.25     -1.21          0     0         0      24.57       0
   7       15.75     -1.15          0     0         0      18.13       0
   8       11.25     -1.07          0     0         0      12.06       0
   9       6.75      -0.96          0     0         0       6.5        0
  10       2.25      -0.89          0     0         0        2         0
       Total         -11.07         0     0         0       251        0
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa      tiz      qz      θ      Force
            m          m                  m2        m2      m2       mm      N/m2    Deg      KN
   1           42      42           1    1.815     0.62    1.516      0      920.2    30     1.19
   2           42      42           1    1.815     0.62    1.516      0      920.2   150     1.19
   3           42      42           1    1.815     0.62     0.62      0      920.2    90     0.48
                            Total                          3.652     ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42    -1.19          0     0         0       49.8     -0.35
   2           42    -1.19          0     0         0       49.8     -0.35
   3           42    -0.48          0     0         0      20.37     0.29
       Total         -2.86          0     0         0      119.98    -0.42
Wind forces from mounts of panel antenna
ASMTower 2018.4                Job No.          40m Guyed Pole                        Rev. No.        A
                               Client           OG                                    Date            5/11/2017
                               Project          GSM Network                           Designed by     M.Joe
                                                                                      Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z             Ka   EPAn      EPAt    EPAa    tiz       qz        θ      Force
           m         m                   m2        m2      m2     mm       N/m2      Deg      KN
   1           42    42            1    0.034     0.358   0.115    0       920.2     30      0.09
   2           42    42            1    0.034     0.358   0.115    0       920.2     150     0.09
   3           42    42            1    0.034     0.358   0.358    0       920.2     90      0.28
                           Total                          0.587    ---      ---      ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx             Fy    Fz       OTMx    OTMz    Torque
            m       KN             KN    KN       KN.m    KN.m     KN.m
   1           42   -0.09          0      0        0      3.77    -0.02
   2           42   -0.09          0      0        0      3.77    -0.02
   3           42   -0.28          0      0        0      11.74    0.11
       Total        -0.46          0      0        0      19.28    0.07
Wind forces from MW dishes
   #       Elev.     Z         O.D.      Area     tiz      qz      θ        Ca       Cs       Cm      Fa      Fs      Mm
            m        m         mm         m2      mm      N/m2    Deg                                 KN      KN      KN
   1           40    40        2400     4.524      0      910.8   330      1.21     -0.23    0.05     4.24    -0.82   0.44
   2           44    44        1200     1.131      0      929.3   210      -0.96    -0.18    -0.06    -0.85   -0.16   -0.07
Wind vectors from MW dishes
   #       Elev.    Fx             Fy    Fz        Mx      My      Mz      OTMx     OTMz     Torque
            m       KN             KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m      KN.m
   1           40   -4.08          0    -1.41      0      0.44     0       -56.38   163.33    0.01
   2           44   -0.82          0     0.29      0      -0.07    0       12.82    36.03     -0.15
       Total        -4.9           0    -1.12      ---     ---     ---     -43.56   199.36    -0.14
Wind forces from mounts Of MW dishes
   #       Elev.     Z             Ka   EPAn      EPAt    EPAa    tiz       qz        θ      Force
            m        m                   m2        m2      m2     mm       N/m2      Deg      KN
   1           40    40            1      0       0.235   0.059    0       910.8     30      0.05
   2           44    44            1    0.034     0.234   0.084    0       929.3     150     0.07
                           Total                          0.143    ---      ---      ---     0.11
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx             Fy    Fz       OTMx    OTMz    Torque
            m       KN             KN    KN       KN.m    KN.m     KN.m
   1           40   -0.05          0      0        0      1.82    -0.01
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   -0.07    0         0             0         2.92     -0.01
       Total        -0.11    0         0             0         4.74     -0.02
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     145.92     577.5     0.03
  2            9     4.5         8            1.2           17.493     77.18      577.5     0.08
  3            9     4.5         8            1.2           17.493     34.08      577.5     0.03
  4            9     4.5         8            1.2           17.493     102.82     577.5     0.08
  5        18         9          8            1.2           23.431     128.2      665.3     0.08
  6        18         9          8            1.2           23.431     80.46      665.3     0.12
  7        18         9          8            1.2           23.431      51.8      665.3     0.08
  8        18         9          8            1.2           23.431     99.54      665.3     0.12
  9        27        13.5        8            1.2           30.887     117.98     724.6     0.14
  10       27        13.5        8            1.2           30.887     82.78      724.6     0.18
  11       27        13.5        8            1.2           30.887     62.02      724.6     0.14
  12       27        13.5        8            1.2           30.887     97.22      724.6     0.18
  13       36         18         16           1.2            39        111.81     769.9     0.42
  14       36         18         16           1.2            39        84.29      769.9     0.49
  15       36         18         16           1.2            39        68.19      769.9     0.42
  16       36         18         16           1.2            39        95.71      769.9     0.49
  17       40         20         20           1.2           42.72      109.83     787.1     0.61
  18       40         20         20           1.2           42.72      84.79      787.1     0.68
  19       40         20         20           1.2           42.72      70.17      787.1     0.61
  20       40         20         20           1.2           42.72      95.21      787.1     0.68
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01     -0.02         0.01       0.08    -0.08    -0.09
  2            9     4.5    -0.08     0.01          -0.01      -0.13    0.33    -0.58
  3            9     4.5    -0.01     0.02          0.01       0.08    -0.08     0.09
  4            9     4.5    -0.08     -0.01         -0.01      -0.13    0.33     0.58
  5        18        9      -0.06     -0.05         0.01       0.18     0.21    -0.19
  6        18        9      -0.12     0.02          -0.01      -0.23    1.07    -0.91
  7        18        9      -0.06     0.05          0.01       0.18     0.21     0.19
  8        18        9      -0.12     -0.02         -0.01      -0.23    1.07     0.91
  9        27       13.5    -0.13     -0.07         0.01       0.26     1.22    -0.31
  10       27       13.5    -0.18     0.02          -0.01      -0.29    2.37    -1.31
  11       27       13.5    -0.13     0.07          0.01       0.26     1.22     0.31
ASMTower 2018.4                     Job No.           40m Guyed Pole                       Rev. No.      A
                                    Client            OG                                   Date          5/11/2017
                                    Project           GSM Network                          Designed by   M.Joe
                                                                                           Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m     KN.m
          m             m
  12       27          13.5         -0.18     -0.02     -0.01   -0.29   2.37     1.31
  13       36              18       -0.39     -0.16     0.02    0.61    5.93     -0.88
  14       36              18       -0.48     0.04      -0.02   -0.65    8.6     -3.53
  15       36              18       -0.39     0.16      0.02    0.61    5.93     0.88
  16       36              18       -0.48     -0.04     -0.02   -0.65    8.6     3.53
  17       40              20       -0.57     -0.2      0.02     0.8    9.94     -1.25
  18       40              20       -0.68     0.06      -0.02   -0.84   13.44    -4.95
  19       40              20       -0.57     0.2       0.02     0.8    9.94     1.25
  20       40              20       -0.68     -0.06     -0.02   -0.84   13.44    4.95
       Total                        -5.4          0     -0.02   -0.45   86.04     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 45
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra      C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2     mm                                m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0       0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5     0      0.97    10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1       0      0.97    10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125    0      0.97    10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125    0      0.97    10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125    0      0.97    9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125    0      0.97    9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125    0      0.97    9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125    0      0.97    9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125    0      0.97    8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125    0      0.97    8.32      1.2    1.35    577.5   0.66
                                              Total                                              13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa    tiz       qz      θ      Force
                    m                m                   m2      m2      m2     mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.516     0      915.5    45      0.4
   2           36 To 40              38           1     1.608   0.456   1.032     0      901      45     0.79
   3           31.5 To 36           33.75         1     1.809   0.513   1.161     0      878.8    45     0.87
   4           27 To 31.5           29.25         1     1.809   0.513   1.161     0      852.7    45     0.84
   5           22.5 To 27           24.75         1     1.809   0.513   1.161     0      823.2    45     0.81
ASMTower 2018.4                  Job No.          40m Guyed Pole                       Rev. No.      A
                                 Client           OG                                   Date          5/11/2017
                                 Project          GSM Network                          Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                   Z     Ka       EPAn    EPAt    EPAa     tiz      qz      θ      Force
                m                    m               m2      m2      m2      mm      N/m2    Deg      KN
   6           18 To 22.5        20.25      1       1.809   0.513   1.161     0      789.2    45     0.78
   7           13.5 To 18        15.75      1       1.809   0.513   1.161     0      748.5    45     0.74
   8           9 To 13.5         11.25      1       1.809   0.513   1.161     0      697.3    45     0.69
   9            4.5 To 9         6.75       1       1.809   0.513   1.161     0      626.2    45     0.62
  10            0 To 4.5         2.25       1       1.809   0.513   1.161     0      577.5    45     0.57
                                 Total                              10.836    ---     ---     ---    7.11
Wind vector from transmission line clusters
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           41    -0.28           0    -0.28    -11.64   11.64    0.09
   2           38    -0.56           0    -0.56    -21.24   21.24    0.17
   3       33.75     -0.61           0    -0.61     -20.7   20.7     0.18
   4       29.25      -0.6           0     -0.6     -17.4   17.4     0.18
   5       24.75     -0.57           0    -0.57    -14.22   14.22    0.17
   6       20.25     -0.55           0    -0.55    -11.15   11.15    0.17
   7       15.75     -0.52           0    -0.52     -8.23   8.23     0.16
   8       11.25     -0.49           0    -0.49     -5.47   5.47     0.15
   9       6.75      -0.44           0    -0.44     -2.95   2.95     0.13
  10       2.25       -0.4           0     -0.4     -0.91   0.91     0.12
       Total         -5.03           0    -5.03    -113.91 113.91    1.51
Wind forces from panel antenna
   #       Elev.       Z             Ka   EPAn      EPAt    EPAa     tiz      qz      θ      Force
            m          m                   m2        m2      m2      mm      N/m2    Deg      KN
   1           42      42            1    1.815     0.62    1.735     0      920.2    15     1.36
   2           42      42            1    1.815     0.62     0.7      0      920.2   105     0.55
   3           42      42            1    1.815     0.62    1.217     0      920.2   135     0.95
                             Total                          3.652    ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           42    -0.96           0    -0.96     -40.3   40.3     0.21
   2           42    -0.39           0    -0.39    -16.26   16.26    -0.31
   3           42    -0.67           0    -0.67    -28.28   28.28     0.4
       Total         -2.02           0    -2.02    -84.84   84.84    0.29
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                        Rev. No.       A
                              Client           OG                                    Date           5/11/2017
                              Project          GSM Network                           Designed by    M.Joe
                                                                                     Checked by     A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz        qz      θ      Force
           m         m                  m2        m2      m2     mm        N/m2    Deg      KN
   1           42    42           1    0.034     0.358   0.056    0       920.2     15     0.04
   2           42    42           1    0.034     0.358   0.336    0       920.2    105     0.26
   3           42    42           1    0.034     0.358   0.196    0       920.2    135     0.15
                          Total                          0.587    ---       ---     ---    0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   -0.03         0    -0.03     -1.29   1.29      0
   2           42   -0.19         0    -0.19     -7.8     7.8     -0.1
   3           42   -0.11         0    -0.11     -4.55   4.55     0.04
       Total        -0.32         0    -0.32    -13.64   13.64   -0.05
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ         Ca      Cs      Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      910.8    15       1.26    0.14    -0.04    4.4     0.48    -0.31
   2           44    44       1200     1.131      0      929.3   255       -0.44   -0.57   -0.11    -0.39   -0.51   -0.12
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx     OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m     KN.m
   1           40   -3.57         0    -2.61      0      -0.31    0       -104.56 142.79    -0.06
   2           44   -0.59         0    -0.24      0      -0.12    0       -10.61   26.16    -0.39
       Total        -4.16         0    -2.86      ---     ---     ---     -115.16 168.94    -0.44
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz        qz      θ      Force
            m        m                  m2        m2      m2     mm        N/m2    Deg      KN
   1           40    40           1      0       0.235   0.016    0       910.8     15     0.01
   2           44    44           1    0.034     0.234   0.22     0       929.3    105     0.17
                          Total                          0.236    ---       ---     ---    0.19
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40   -0.01         0    -0.01     -0.34   0.34      0
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   -0.12    0        -0.12         -5.41      5.41     -0.06
       Total        -0.13    0        -0.13         -5.76      5.76     -0.06
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     137.95     577.5     0.04
  2            9     4.5         8            1.2           17.493     115.39     577.5     0.07
  3            9     4.5         8            1.2           17.493     42.05      577.5     0.04
  4            9     4.5         8            1.2           17.493     64.61      577.5     0.07
  5        18         9          8            1.2           23.431     123.67     665.3     0.09
  6        18         9          8            1.2           23.431     108.67     665.3     0.11
  7        18         9          8            1.2           23.431     56.33      665.3     0.09
  8        18         9          8            1.2           23.431     71.33      665.3     0.11
  9        27        13.5        8            1.2           30.887     114.87     724.6     0.15
  10       27        13.5        8            1.2           30.887     104.05     724.6     0.17
  11       27        13.5        8            1.2           30.887     65.13      724.6     0.15
  12       27        13.5        8            1.2           30.887     75.95      724.6     0.17
  13       36         18         16           1.2            39        109.46     769.9     0.44
  14       36         18         16           1.2            39        101.09     769.9     0.47
  15       36         18         16           1.2            39        70.54      769.9     0.44
  16       36         18         16           1.2            39        78.91      769.9     0.47
  17       40         20         20           1.2           42.72      107.7      787.1     0.62
  18       40         20         20           1.2           42.72      100.11     787.1     0.66
  19       40         20         20           1.2           42.72       72.3      787.1     0.62
  20       40         20         20           1.2           42.72      79.89      787.1     0.66
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01     -0.02         -0.03      -0.09   -0.13     0.21
  2            9     4.5    -0.06     -0.02         -0.03         0     0.3     -0.48
  3            9     4.5    -0.01     0.02          -0.03      -0.09   -0.13    -0.21
  4            9     4.5    -0.06     0.02          -0.03         0     0.3      0.48
  5        18        9      -0.04     -0.05         -0.07      -0.5     0.02     0.4
  6        18        9      -0.09     -0.03         -0.06      -0.34    0.88    -0.78
  7        18        9      -0.04     0.05          -0.07      -0.5     0.02     -0.4
  8        18        9      -0.09     0.03          -0.06      -0.34    0.88     0.78
  9        27       13.5    -0.08     -0.06         -0.11      -1.35    0.7      0.62
  10       27       13.5    -0.13     -0.04         -0.11      -1.15    1.84    -1.15
  11       27       13.5    -0.08     0.06          -0.11      -1.35    0.7     -0.62
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.      A
                                    Client            OG                                    Date          5/11/2017
                                    Project           GSM Network                           Designed by   M.Joe
                                                                                            Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m     KN.m
          m             m
  12       27          13.5         -0.13     0.04      -0.11   -1.15    1.84     1.15
  13       36              18       -0.27     -0.14     -0.31   -5.33    3.82     1.73
  14       36              18       -0.35     -0.09     -0.31   -4.88    6.45     -3.12
  15       36              18       -0.27     0.14      -0.31   -5.33    3.82     -1.73
  16       36              18       -0.35     0.09      -0.31   -4.88    6.45     3.12
  17       40              20       -0.39     -0.19     -0.44   -8.52    6.55     2.45
  18       40              20       -0.49     -0.11     -0.44   -7.94    9.98     -4.39
  19       40              20       -0.39     0.19      -0.44   -8.52    6.55     -2.45
  20       40              20       -0.49     0.11      -0.44   -7.94    9.98     4.39
       Total                        -3.82         0     -3.79   -60.19   60.82     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 90
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra      C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2      mm                                m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0       0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5      0       0.3    10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1        0       0.3    10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125     0       0.3    10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125     0       0.3    10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125     0       0.3    9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125     0       0.3    9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125     0       0.3    9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125     0       0.3    9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125     0       0.3    8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125     0       0.3    8.32      1.2    1.35    577.5   0.66
                                              Total                                               13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa    tiz       qz      θ      Force
                    m                m                   m2      m2       m2     mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228    0.228     0      915.5    90     0.18
   2           36 To 40              38           1     1.608   0.456    0.456     0      901      90     0.35
   3           31.5 To 36           33.75         1     1.809   0.513    0.513     0      878.8    90     0.38
   4           27 To 31.5           29.25         1     1.809   0.513    0.513     0      852.7    90     0.37
   5           22.5 To 27           24.75         1     1.809   0.513    0.513     0      823.2    90     0.36
ASMTower 2018.4                 Job No.          40m Guyed Pole                        Rev. No.      A
                                Client           OG                                    Date          5/11/2017
                                Project          GSM Network                           Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn     EPAt    EPAa     tiz      qz      θ      Force
                m                   m               m2       m2      m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809    0.513   0.513     0      789.2    90     0.34
   7           13.5 To 18       15.75      1       1.809    0.513   0.513     0      748.5    90     0.33
   8           9 To 13.5        11.25      1       1.809    0.513   0.513     0      697.3    90      0.3
   9            4.5 To 9        6.75       1       1.809    0.513   0.513     0      626.2    90     0.27
  10            0 To 4.5        2.25       1       1.809    0.513   0.513     0      577.5    90     0.25
                                Total                               4.788     ---     ---     ---    3.14
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx     OTMz    Torque
            m         KN            KN    KN       KN.m     KN.m     KN.m
   1           41      0            0    -0.18     -7.27     0       0.05
   2           38      0            0    -0.35    -13.27     0       0.1
   3       33.75       0            0    -0.38    -12.93     0       0.11
   4       29.25       0            0    -0.37    -10.88     0       0.11
   5       24.75       0            0    -0.36     -8.88     0       0.11
   6       20.25       0            0    -0.34     -6.97     0       0.1
   7       15.75       0            0    -0.33     -5.14     0       0.1
   8       11.25       0            0     -0.3     -3.42     0       0.09
   9       6.75        0            0    -0.27     -1.84     0       0.08
  10       2.25        0            0    -0.25     -0.57     0       0.08
       Total           0            0    -3.14    -71.18     0       0.94
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt     EPAa    tiz       qz      θ      Force
            m          m                  m2        m2       m2     mm       N/m2    Deg      KN
   1           42      42           1    1.815     0.62     0.919     0      920.2    60     0.72
   2           42      42           1    1.815     0.62     0.919     0      920.2    60     0.72
   3           42      42           1    1.815     0.62     1.815     0      920.2   180     1.42
                            Total                           3.652    ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx     OTMz    Torque
            m         KN            KN    KN       KN.m     KN.m     KN.m
   1           42      0            0    -0.72    -30.18     0       0.37
   2           42      0            0    -0.72    -30.18     0       -0.37
   3           42      0            0    -1.42    -59.62     0        0
       Total           0            0    -2.86    -119.98    0        0
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                         Rev. No.        A
                              Client           OG                                     Date            5/11/2017
                              Project          GSM Network                            Designed by     M.Joe
                                                                                      Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz        qz       θ       Force
           m         m                  m2        m2      m2     mm        N/m2     Deg       KN
   1           42    42           1    0.034     0.358   0.277    0       920.2      60      0.22
   2           42    42           1    0.034     0.358   0.277    0       920.2      60      0.22
   3           42    42           1    0.034     0.358   0.034    0       920.2      180     0.03
                          Total                          0.587    ---       ---      ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42    0            0    -0.22     -9.09    0       0.07
   2           42    0            0    -0.22     -9.09    0      -0.07
   3           42    0            0    -0.03     -1.11    0        0
       Total         0            0    -0.46    -19.28    0        0
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ         Ca       Cs       Cm      Fa     Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                  KN     KN      KN
   1           40    40       2400     4.524      0      910.8    60       0.95     0.37     -0.01    3.31   1.29    -0.07
   2           44    44       1200     1.131      0      929.3   300       0.95     -0.37    0.01     0.84   -0.33   0.01
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx      OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m      KN.m      KN.m
   1           40   -2.22         0    -2.77      0      -0.07    0       -110.76   88.97     0.6
   2           44   0.57          0    -0.71      0      0.01     0       -31.08    -24.96    -0.16
       Total        -1.66         0    -3.48      ---     ---     ---     -141.84    64       0.44
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz        qz       θ       Force
            m        m                  m2        m2      m2     mm        N/m2     Deg       KN
   1           40    40           1      0       0.235   0.176    0       910.8      60      0.14
   2           44    44           1    0.034     0.234   0.184    0       929.3      60      0.15
                          Total                          0.36     ---       ---      ---     0.28
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40    0            0    -0.14     -5.45    0       0.04
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44    0       0        -0.15         -6.39         0     -0.05
       Total         0       0        -0.28     -11.84            0       0
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     102.82     577.5     0.08
  2            9     4.5         8            1.2           17.493     145.92     577.5     0.03
  3            9     4.5         8            1.2           17.493     77.18      577.5     0.08
  4            9     4.5         8            1.2           17.493     34.08      577.5     0.03
  5        18         9          8            1.2           23.431     99.54      665.3     0.12
  6        18         9          8            1.2           23.431     128.2      665.3     0.08
  7        18         9          8            1.2           23.431     80.46      665.3     0.12
  8        18         9          8            1.2           23.431      51.8      665.3     0.08
  9        27        13.5        8            1.2           30.887     97.22      724.6     0.18
  10       27        13.5        8            1.2           30.887     117.98     724.6     0.14
  11       27        13.5        8            1.2           30.887     82.78      724.6     0.18
  12       27        13.5        8            1.2           30.887     62.02      724.6     0.14
  13       36         18         16           1.2            39        95.71      769.9     0.49
  14       36         18         16           1.2            39        111.81     769.9     0.42
  15       36         18         16           1.2            39        84.29      769.9     0.49
  16       36         18         16           1.2            39        68.19      769.9     0.42
  17       40         20         20           1.2           42.72      95.21      787.1     0.68
  18       40         20         20           1.2           42.72      109.83     787.1     0.61
  19       40         20         20           1.2           42.72      84.79      787.1     0.68
  20       40         20         20           1.2           42.72      70.17      787.1     0.61
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01      -0.01         -0.08      -0.33   -0.13     0.58
  2            9     4.5    -0.01     -0.02         -0.01      0.08     0.08    -0.09
  3            9     4.5    0.01      0.01          -0.08      -0.33   -0.13    -0.58
  4            9     4.5    -0.01     0.02          -0.01      0.08     0.08     0.09
  5        18        9      0.01      -0.02         -0.12      -1.07   -0.23     0.91
  6        18        9      -0.01     -0.05         -0.06      -0.21    0.18    -0.19
  7        18        9      0.01      0.02          -0.12      -1.07   -0.23    -0.91
  8        18        9      -0.01     0.05          -0.06      -0.21    0.18     0.19
  9        27       13.5    0.01      -0.02         -0.18      -2.37   -0.29     1.31
  10       27       13.5    -0.01     -0.07         -0.13      -1.22    0.26    -0.31
  11       27       13.5    0.01      0.02          -0.18      -2.37   -0.29    -1.31
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.      A
                                    Client            OG                                    Date          5/11/2017
                                    Project           GSM Network                           Designed by   M.Joe
                                                                                            Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m     KN.m
          m             m
  12       27          13.5         -0.01     0.07      -0.13   -1.22    0.26     0.31
  13       36              18       0.02      -0.04     -0.48    -8.6    -0.65    3.53
  14       36              18       -0.02     -0.16     -0.39   -5.93    0.61     -0.88
  15       36              18       0.02      0.04      -0.48    -8.6    -0.65    -3.53
  16       36              18       -0.02     0.16      -0.39   -5.93    0.61     0.88
  17       40              20       0.02      -0.06     -0.68   -13.44   -0.84    4.95
  18       40              20       -0.02     -0.2      -0.57   -9.94     0.8     -1.25
  19       40              20       0.02      0.06      -0.68   -13.44   -0.84    -4.95
  20       40              20       -0.02     0.2       -0.57   -9.94     0.8     1.25
       Total                        0.02          0     -5.4    -86.04   -0.45     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 135
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra      C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2      mm                                m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0       0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5      0      0.84    10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1        0      0.84    10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125     0      0.84    10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125     0      0.84    10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125     0      0.84    9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125     0      0.84    9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125     0      0.84    9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125     0      0.84    9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125     0      0.84    8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125     0      0.84    8.32      1.2    1.35    577.5   0.66
                                              Total                                               13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa    tiz       qz      θ      Force
                    m                m                   m2      m2       m2     mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228    0.443     0      915.5   135     0.34
   2           36 To 40              38           1     1.608   0.456    0.886     0      901     135     0.68
   3           31.5 To 36           33.75         1     1.809   0.513    0.996     0      878.8   135     0.74
   4           27 To 31.5           29.25         1     1.809   0.513    0.996     0      852.7   135     0.72
   5           22.5 To 27           24.75         1     1.809   0.513    0.996     0      823.2   135      0.7
ASMTower 2018.4                 Job No.          40m Guyed Pole                        Rev. No.      A
                                Client           OG                                    Date          5/11/2017
                                Project          GSM Network                           Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz      qz      θ      Force
                m                   m               m2      m2       m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513    0.996     0      789.2   135     0.67
   7           13.5 To 18       15.75     1        1.809   0.513    0.996     0      748.5   135     0.63
   8           9 To 13.5        11.25     1        1.809   0.513    0.996     0      697.3   135     0.59
   9            4.5 To 9        6.75      1        1.809   0.513    0.996     0      626.2   135     0.53
  10            0 To 4.5        2.25      1        1.809   0.513    0.996     0      577.5   135     0.49
                                Total                                9.3      ---     ---     ---     6.1
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41     0.24          0    -0.24     -9.99   -9.99     0.07
   2           38     0.48          0    -0.48    -18.23   -18.23    0.14
   3       33.75      0.53          0    -0.53    -17.76   -17.76    0.16
   4       29.25      0.51          0    -0.51    -14.94   -14.94    0.15
   5       24.75      0.49          0    -0.49     -12.2   -12.2     0.15
   6       20.25      0.47          0    -0.47     -9.57   -9.57     0.14
   7       15.75      0.45          0    -0.45     -7.06   -7.06     0.13
   8       11.25      0.42          0    -0.42     -4.7     -4.7     0.13
   9       6.75       0.38          0    -0.38     -2.53   -2.53     0.11
  10       2.25       0.35          0    -0.35     -0.78   -0.78     0.1
       Total          4.31          0    -4.31    -97.76   -97.76    1.29
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz      θ      Force
            m          m                  m2        m2      m2      mm       N/m2    Deg      KN
   1           42      42           1    1.815     0.62     0.7       0      920.2   105     0.55
   2           42      42           1    1.815     0.62    1.735      0      920.2    15     1.36
   3           42      42           1    1.815     0.62    1.217      0      920.2   135     0.95
                            Total                          3.652     ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42     0.39          0    -0.39    -16.26   -16.26    0.31
   2           42     0.96          0    -0.96     -40.3   -40.3     -0.21
   3           42     0.67          0    -0.67    -28.28   -28.28    -0.4
       Total          2.02          0    -2.02    -84.84   -84.84    -0.29
Wind forces from mounts of panel antenna
ASMTower 2018.4              Job No.          40m Guyed Pole                         Rev. No.        A
                             Client           OG                                     Date            5/11/2017
                             Project          GSM Network                            Designed by     M.Joe
                                                                                     Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z           Ka   EPAn      EPAt    EPAa     tiz       qz       θ       Force
           m         m                 m2        m2      m2      mm       N/m2     Deg       KN
   1           42   42           1    0.034     0.358   0.336     0       920.2     105     0.26
   2           42   42           1    0.034     0.358   0.056     0       920.2     15      0.04
   3           42   42           1    0.034     0.358   0.196     0       920.2     135     0.15
                         Total                          0.587     ---      ---      ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m      KN.m
   1           42   0.19         0    -0.19     -7.8     -7.8     0.1
   2           42   0.03         0    -0.03     -1.29   -1.29      0
   3           42   0.11         0    -0.11     -4.55   -4.55    -0.04
       Total        0.32         0    -0.32    -13.64   -13.64    0.05
Wind forces from MW dishes
   #       Elev.     Z       O.D.      Area     tiz      qz       θ        Ca       Cs       Cm      Fa      Fs      Mm
            m        m       mm         m2      mm      N/m2     Deg                                 KN      KN      KN
   1           40   40       2400     4.524      0      910.8    105      -0.44    0.57     0.11     -1.55   1.98    0.95
   2           44   44       1200     1.131      0      929.3    345      1.26     -0.14    0.04     1.12    -0.12   0.04
Wind vectors from MW dishes
   #       Elev.    Fx           Fy    Fz        Mx      My       Mz      OTMx     OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m     KN.m     KN.m      KN.m
   1           40   2.33         0    -0.95      0      0.95      0       -37.8    -93.24    1.99
   2           44   0.91         0    -0.67      0      0.04      0       -29.34   -40.06    -0.02
       Total        3.24         0    -1.61      ---     ---      ---     -67.14   -133.3    1.97
Wind forces from mounts Of MW dishes
   #       Elev.     Z           Ka   EPAn      EPAt    EPAa     tiz       qz       θ       Force
            m        m                 m2        m2      m2      mm       N/m2     Deg       KN
   1           40   40           1      0       0.235   0.219     0       910.8     105     0.17
   2           44   44           1    0.034     0.234   0.048     0       929.3     15      0.04
                         Total                          0.266     ---      ---      ---     0.21
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m      KN.m
   1           40   0.12         0    -0.12     -4.79   -4.79     0.06
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   0.03     0        -0.03         -1.17      -1.17      0
       Total        0.15     0        -0.15         -5.96      -5.96    0.06
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd             Lg          θg        qz       Fw
          Elev.     Elev.     mm                             m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     64.61      577.5     0.07
  2            9     4.5         8            1.2           17.493     137.95     577.5     0.04
  3            9     4.5         8            1.2           17.493     115.39     577.5     0.07
  4            9     4.5         8            1.2           17.493     42.05      577.5     0.04
  5        18         9          8            1.2           23.431     71.33      665.3     0.11
  6        18         9          8            1.2           23.431     123.67     665.3     0.09
  7        18         9          8            1.2           23.431     108.67     665.3     0.11
  8        18         9          8            1.2           23.431     56.33      665.3     0.09
  9        27        13.5        8            1.2           30.887     75.95      724.6     0.17
  10       27        13.5        8            1.2           30.887     114.87     724.6     0.15
  11       27        13.5        8            1.2           30.887     104.05     724.6     0.17
  12       27        13.5        8            1.2           30.887     65.13      724.6     0.15
  13       36         18         16           1.2            39        78.91      769.9     0.47
  14       36         18         16           1.2            39        109.46     769.9     0.44
  15       36         18         16           1.2            39        101.09     769.9     0.47
  16       36         18         16           1.2            39        70.54      769.9     0.44
  17       40         20         20           1.2           42.72      79.89      787.1     0.66
  18       40         20         20           1.2           42.72      107.7      787.1     0.62
  19       40         20         20           1.2           42.72      100.11     787.1     0.66
  20       40         20         20           1.2           42.72       72.3      787.1     0.62
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.03      0.02          -0.06      -0.3      0       0.48
  2            9     4.5    0.03      -0.02         -0.01      0.13    -0.09     0.21
  3            9     4.5    0.03      -0.02         -0.06      -0.3      0      -0.48
  4            9     4.5    0.03      0.02          -0.01      0.13    -0.09    -0.21
  5        18        9      0.06      0.03          -0.09      -0.88   -0.34     0.78
  6        18        9      0.07      -0.05         -0.04      -0.02    -0.5     0.4
  7        18        9      0.06      -0.03         -0.09      -0.88   -0.34    -0.78
  8        18        9      0.07      0.05          -0.04      -0.02    -0.5     -0.4
  9        27       13.5    0.11      0.04          -0.13      -1.84   -1.15     1.15
  10       27       13.5    0.11      -0.06         -0.08      -0.7    -1.35     0.62
  11       27       13.5    0.11      -0.04         -0.13      -1.84   -1.15    -1.15
ASMTower 2018.4                     Job No.           40m Guyed Pole                         Rev. No.      A
                                    Client            OG                                     Date          5/11/2017
                                    Project           GSM Network                            Designed by   M.Joe
                                                                                             Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m      KN.m
          m             m
  12       27          13.5         0.11      0.06      -0.08    -0.7    -1.35     -0.62
  13       36              18       0.31      0.09      -0.35   -6.45    -4.88     3.12
  14       36              18       0.31      -0.14     -0.27   -3.82    -5.33     1.73
  15       36              18       0.31      -0.09     -0.35   -6.45    -4.88     -3.12
  16       36              18       0.31      0.14      -0.27   -3.82    -5.33     -1.73
  17       40              20       0.44      0.11      -0.49   -9.98    -7.94     4.39
  18       40              20       0.44      -0.19     -0.39   -6.55    -8.52     2.45
  19       40              20       0.44      -0.11     -0.49   -9.98    -7.94     -4.39
  20       40              20       0.44      0.19      -0.39   -6.55    -8.52     -2.45
       Total                        3.79          0     -3.82   -60.82   -60.19     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 180
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra       C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2      mm                                 m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0        0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5      0      0.07     10.48     0.6     0.3    915.5   0.23
   2           1           38        4        0.25       1        0      0.07     10.4      0.6     0.6    901     0.46
   3           1       33.75         4.5      0.25      1.125     0      0.07     10.27     0.6    0.675   878.8    0.5
               2       29.25         4.5      0.25      1.125     0      0.07     10.11     0.6    0.675   852.7   0.49
   4           1       24.75         4.5      0.25      1.125     0      0.07     9.94      0.6    0.675   823.2   0.47
               2       20.25         4.5      0.25      1.125     0      0.07     9.73      0.6    0.675   789.2   0.45
   5           1       15.75         4.5      0.25      1.125     0      0.07     9.48      0.6    0.675   748.5   0.43
               2       11.25         4.5      0.25      1.125     0      0.07     9.15      0.6    0.675   697.3    0.4
   6           1       6.75          4.5      0.25      1.125     0      0.07     8.67      0.6    0.679   626.2   0.36
               2       2.25          4.5      0.25      1.125     0      0.07     8.32     0.63    0.707   577.5   0.35
                                              Total                                                6.786    ---     4.5
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa     tiz       qz      θ      Force
                    m                m                   m2      m2       m2      mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228      0        0      915.5   180      0
   2           36 To 40              38           1     1.608   0.456      0        0      901     180      0
   3           31.5 To 36           33.75         1     1.809   0.513      0        0      878.8   180      0
   4           27 To 31.5           29.25         1     1.809   0.513      0        0      852.7   180      0
   5           22.5 To 27           24.75         1     1.809   0.513      0        0      823.2   180      0
ASMTower 2018.4                 Job No.          40m Guyed Pole                         Rev. No.      A
                                Client           OG                                     Date          5/11/2017
                                Project          GSM Network                            Designed by   M.Joe
                                                                                        Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn     EPAt     EPAa     tiz      qz      θ      Force
                m                   m               m2       m2       m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513      0        0      789.2   180      0
   7           13.5 To 18       15.75     1        1.809   0.513      0        0      748.5   180      0
   8           9 To 13.5        11.25     1        1.809   0.513      0        0      697.3   180      0
   9            4.5 To 9        6.75      1        1.809   0.513      0        0      626.2   180      0
  10            0 To 4.5        2.25      1        1.809   0.513      0        0      577.5   180      0
                                Total                                 0        ---     ---     ---     0
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz      Torque
            m         KN            KN    KN       KN.m    KN.m       KN.m
   1           41      0            0     0         0        0         0
   2           38      0            0     0         0        0         0
   3       33.75       0            0     0         0        0         0
   4       29.25       0            0     0         0        0         0
   5       24.75       0            0     0         0        0         0
   6       20.25       0            0     0         0        0         0
   7       15.75       0            0     0         0        0         0
   8       11.25       0            0     0         0        0         0
   9       6.75        0            0     0         0        0         0
  10       2.25        0            0     0         0        0         0
       Total           0            0     0         0        0         0
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa      tiz       qz      θ      Force
            m          m                  m2        m2       m2      mm       N/m2    Deg      KN
   1           42      42           1    1.815     0.62    1.516      0       920.2   150     1.19
   2           42      42           1    1.815     0.62    1.516      0       920.2    30     1.19
   3           42      42           1    1.815     0.62     0.62      0       920.2    90     0.48
                            Total                          3.652      ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz      Torque
            m         KN            KN    KN       KN.m    KN.m       KN.m
   1           42     1.19          0     0         0       -49.8     0.35
   2           42     1.19          0     0         0       -49.8     0.35
   3           42     0.48          0     0         0      -20.37    -0.29
       Total          2.86          0     0         0      -119.98    0.42
Wind forces from mounts of panel antenna
ASMTower 2018.4              Job No.          40m Guyed Pole                          Rev. No.        A
                             Client           OG                                      Date            5/11/2017
                             Project          GSM Network                             Designed by     M.Joe
                                                                                      Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z           Ka   EPAn      EPAt    EPAa     tiz       qz        θ       Force
           m         m                 m2        m2      m2      mm       N/m2      Deg       KN
   1           42   42           1    0.034     0.358   0.115     0       920.2     150      0.09
   2           42   42           1    0.034     0.358   0.115     0       920.2      30      0.09
   3           42   42           1    0.034     0.358   0.358     0       920.2      90      0.28
                         Total                          0.587     ---      ---       ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m      KN.m
   1           42   0.09         0      0        0      -3.77     0.02
   2           42   0.09         0      0        0      -3.77     0.02
   3           42   0.28         0      0        0      -11.74   -0.11
       Total        0.46         0      0        0      -19.28   -0.07
Wind forces from MW dishes
   #       Elev.     Z       O.D.      Area     tiz      qz       θ        Ca        Cs       Cm      Fa      Fs     Mm
            m        m       mm         m2      mm      N/m2     Deg                                  KN      KN     KN
   1           40   40       2400     4.524      0      910.8    150      -0.96     0.18     0.06     -3.35   0.62   0.52
   2           44   44       1200     1.131      0      929.3     30      1.21      0.23     -0.05    1.08    0.21   -0.06
Wind vectors from MW dishes
   #       Elev.    Fx           Fy    Fz        Mx      My       Mz      OTMx     OTMz      Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m     KN.m     KN.m       KN.m
   1           40   3.21         0     1.14      0      0.52      0       45.71    -128.42    0.84
   2           44   1.04         0    -0.36      0      -0.06     0       -15.82   -45.83     0.05
       Total        4.25         0     0.78      ---     ---      ---     29.89    -174.25    0.9
Wind forces from mounts Of MW dishes
   #       Elev.     Z           Ka   EPAn      EPAt    EPAa     tiz       qz        θ       Force
            m        m                 m2        m2      m2      mm       N/m2      Deg       KN
   1           40   40           1      0       0.235   0.059     0       910.8     150      0.05
   2           44   44           1    0.034     0.234   0.084     0       929.3      30      0.07
                         Total                          0.143     ---      ---       ---     0.11
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m      KN.m
   1           40   0.05         0      0        0      -1.82     0.01
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   0.07     0         0             0         -2.92    0.01
       Total        0.11     0         0             0         -4.74    0.02
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd             Lg          θg        qz       Fw
          Elev.     Elev.     mm                             m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     34.08      577.5     0.03
  2            9     4.5         8            1.2           17.493     102.82     577.5     0.08
  3            9     4.5         8            1.2           17.493     145.92     577.5     0.03
  4            9     4.5         8            1.2           17.493     77.18      577.5     0.08
  5        18         9          8            1.2           23.431      51.8      665.3     0.08
  6        18         9          8            1.2           23.431     99.54      665.3     0.12
  7        18         9          8            1.2           23.431     128.2      665.3     0.08
  8        18         9          8            1.2           23.431     80.46      665.3     0.12
  9        27        13.5        8            1.2           30.887     62.02      724.6     0.14
  10       27        13.5        8            1.2           30.887     97.22      724.6     0.18
  11       27        13.5        8            1.2           30.887     117.98     724.6     0.14
  12       27        13.5        8            1.2           30.887     82.78      724.6     0.18
  13       36         18         16           1.2            39        68.19      769.9     0.42
  14       36         18         16           1.2            39        95.71      769.9     0.49
  15       36         18         16           1.2            39        111.81     769.9     0.42
  16       36         18         16           1.2            39        84.29      769.9     0.49
  17       40         20         20           1.2           42.72      70.17      787.1     0.61
  18       40         20         20           1.2           42.72      95.21      787.1     0.68
  19       40         20         20           1.2           42.72      109.83     787.1     0.61
  20       40         20         20           1.2           42.72      84.79      787.1     0.68
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01      0.02          -0.01      -0.08    0.08     0.09
  2            9     4.5    0.08      -0.01         0.01       0.13    -0.33     0.58
  3            9     4.5    0.01      -0.02         -0.01      -0.08    0.08    -0.09
  4            9     4.5    0.08      0.01          0.01       0.13    -0.33    -0.58
  5        18        9      0.06      0.05          -0.01      -0.18   -0.21     0.19
  6        18        9      0.12      -0.02         0.01       0.23    -1.07     0.91
  7        18        9      0.06      -0.05         -0.01      -0.18   -0.21    -0.19
  8        18        9      0.12      0.02          0.01       0.23    -1.07    -0.91
  9        27       13.5    0.13      0.07          -0.01      -0.26   -1.22     0.31
  10       27       13.5    0.18      -0.02         0.01       0.29    -2.37     1.31
  11       27       13.5    0.13      -0.07         -0.01      -0.26   -1.22    -0.31
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.      A
                                    Client            OG                                    Date          5/11/2017
                                    Project           GSM Network                           Designed by   M.Joe
                                                                                            Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m      KN.m
          m             m
  12       27          13.5         0.18      0.02      0.01    0.29    -2.37     -1.31
  13       36              18       0.39      0.16      -0.02   -0.61   -5.93     0.88
  14       36              18       0.48      -0.04     0.02    0.65     -8.6     3.53
  15       36              18       0.39      -0.16     -0.02   -0.61   -5.93     -0.88
  16       36              18       0.48      0.04      0.02    0.65     -8.6     -3.53
  17       40              20       0.57      0.2       -0.02   -0.8    -9.94     1.25
  18       40              20       0.68      -0.06     0.02    0.84    -13.44    4.95
  19       40              20       0.57      -0.2      -0.02   -0.8    -9.94     -1.25
  20       40              20       0.68      0.06      0.02    0.84    -13.44    -4.95
       Total                         5.4          0     0.02    0.45    -86.04     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 225
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra       C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2     mm                                 m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0        0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5     0      0.84     10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1       0      0.84     10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125    0      0.84     10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125    0      0.84     10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125    0      0.84     9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125    0      0.84     9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125    0      0.84     9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125    0      0.84     9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125    0      0.84     8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125    0      0.84     8.32      1.2    1.35    577.5   0.66
                                              Total                                               13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa     tiz       qz      θ      Force
                    m                m                   m2      m2      m2      mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.443      0      915.5   135     0.34
   2           36 To 40              38           1     1.608   0.456   0.886      0      901     135     0.68
   3           31.5 To 36           33.75         1     1.809   0.513   0.996      0      878.8   135     0.74
   4           27 To 31.5           29.25         1     1.809   0.513   0.996      0      852.7   135     0.72
   5           22.5 To 27           24.75         1     1.809   0.513   0.996      0      823.2   135      0.7
ASMTower 2018.4                 Job No.          40m Guyed Pole                        Rev. No.      A
                                Client           OG                                    Date          5/11/2017
                                Project          GSM Network                           Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz      qz      θ      Force
                m                   m               m2      m2       m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513    0.996     0      789.2   135     0.67
   7           13.5 To 18       15.75      1       1.809   0.513    0.996     0      748.5   135     0.63
   8           9 To 13.5        11.25      1       1.809   0.513    0.996     0      697.3   135     0.59
   9            4.5 To 9        6.75       1       1.809   0.513    0.996     0      626.2   135     0.53
  10            0 To 4.5        2.25       1       1.809   0.513    0.996     0      577.5   135     0.49
                                Total                                9.3      ---     ---     ---     6.1
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41     0.24          0     0.24     9.99    -9.99     -0.07
   2           38     0.48          0     0.48     18.23   -18.23    -0.14
   3       33.75      0.53          0     0.53     17.76   -17.76    -0.16
   4       29.25      0.51          0     0.51     14.94   -14.94    -0.15
   5       24.75      0.49          0     0.49     12.2    -12.2     -0.15
   6       20.25      0.47          0     0.47     9.57    -9.57     -0.14
   7       15.75      0.45          0     0.45     7.06    -7.06     -0.13
   8       11.25      0.42          0     0.42      4.7     -4.7     -0.13
   9       6.75       0.38          0     0.38     2.53    -2.53     -0.11
  10       2.25       0.35          0     0.35     0.78    -0.78     -0.1
       Total          4.31          0     4.31     97.76   -97.76    -1.29
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz      θ      Force
            m          m                  m2        m2      m2      mm       N/m2    Deg      KN
   1           42      42           1    1.815     0.62    1.735      0      920.2   165     1.36
   2           42      42           1    1.815     0.62     0.7       0      920.2    75     0.55
   3           42      42           1    1.815     0.62    1.217      0      920.2    45     0.95
                            Total                          3.652     ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42     0.96          0     0.96     40.3    -40.3     -0.21
   2           42     0.39          0     0.39     16.26   -16.26    0.31
   3           42     0.67          0     0.67     28.28   -28.28    -0.4
       Total          2.02          0     2.02     84.84   -84.84    -0.29
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                         Rev. No.        A
                              Client           OG                                     Date            5/11/2017
                              Project          GSM Network                            Designed by     M.Joe
                                                                                      Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz       θ       Force
           m         m                  m2        m2      m2      mm       N/m2     Deg       KN
   1           42   42            1    0.034     0.358   0.056     0       920.2    165      0.04
   2           42   42            1    0.034     0.358   0.336     0       920.2     75      0.26
   3           42   42            1    0.034     0.358   0.196     0       920.2     45      0.15
                          Total                          0.587     ---      ---      ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m      KN.m
   1           42   0.03          0     0.03     1.29    -1.29      0
   2           42   0.19          0     0.19      7.8     -7.8     0.1
   3           42   0.11          0     0.11     4.55    -4.55    -0.04
       Total        0.32          0     0.32     13.64   -13.64    0.05
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz       θ        Ca       Cs       Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2     Deg                                 KN      KN      KN
   1           40   40        2400     4.524      0      910.8    195      -0.98    -0.12    -0.03    -3.45   -0.43   -0.28
   2           44   44        1200     1.131      0      929.3     75      0.47     0.53     0.05     0.42    0.47    0.05
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My       Mz      OTMx    OTMz      Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m     KN.m    KN.m       KN.m
   1           40   2.77          0     2.1       0      -0.28     0       83.88   -110.81    -0.51
   2           44   0.6           0     0.2       0      0.05      0       8.73    -26.49     0.3
       Total        3.37          0     2.3       ---     ---      ---     92.61   -137.3     -0.21
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa     tiz       qz       θ       Force
            m        m                  m2        m2      m2      mm       N/m2     Deg       KN
   1           40   40            1      0       0.235   0.016     0       910.8    165      0.01
   2           44   44            1    0.034     0.234   0.22      0       929.3     75      0.17
                          Total                          0.236     ---      ---      ---     0.19
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m      KN.m
   1           40   0.01          0     0.01     0.34    -0.34      0
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44   0.12     0        0.12          5.41      -5.41    0.06
       Total        0.13     0        0.13          5.76      -5.76    0.06
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd            Lg          θg        qz       Fw
          Elev.     Elev.     mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     42.05      577.5     0.04
  2            9     4.5         8            1.2          17.493     64.61      577.5     0.07
  3            9     4.5         8            1.2          17.493     137.95     577.5     0.04
  4            9     4.5         8            1.2          17.493     115.39     577.5     0.07
  5        18         9          8            1.2          23.431     56.33      665.3     0.09
  6        18         9          8            1.2          23.431     71.33      665.3     0.11
  7        18         9          8            1.2          23.431     123.67     665.3     0.09
  8        18         9          8            1.2          23.431     108.67     665.3     0.11
  9        27        13.5        8            1.2          30.887     65.13      724.6     0.15
  10       27        13.5        8            1.2          30.887     75.95      724.6     0.17
  11       27        13.5        8            1.2          30.887     114.87     724.6     0.15
  12       27        13.5        8            1.2          30.887     104.05     724.6     0.17
  13       36         18         16           1.2           39        70.54      769.9     0.44
  14       36         18         16           1.2           39        78.91      769.9     0.47
  15       36         18         16           1.2           39        109.46     769.9     0.44
  16       36         18         16           1.2           39        101.09     769.9     0.47
  17       40         20         20           1.2          42.72       72.3      787.1     0.62
  18       40         20         20           1.2          42.72      79.89      787.1     0.66
  19       40         20         20           1.2          42.72      107.7      787.1     0.62
  20       40         20         20           1.2          42.72      100.11     787.1     0.66
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01      0.02          0.03      0.09     0.13    -0.21
  2            9     4.5    0.06      0.02          0.03         0     -0.3     0.48
  3            9     4.5    0.01      -0.02         0.03      0.09     0.13     0.21
  4            9     4.5    0.06      -0.02         0.03         0     -0.3    -0.48
  5        18        9      0.04      0.05          0.07      0.5     -0.02     -0.4
  6        18        9      0.09      0.03          0.06      0.34    -0.88     0.78
  7        18        9      0.04      -0.05         0.07      0.5     -0.02     0.4
  8        18        9      0.09      -0.03         0.06      0.34    -0.88    -0.78
  9        27       13.5    0.08      0.06          0.11      1.35     -0.7    -0.62
  10       27       13.5    0.13      0.04          0.11      1.15    -1.84     1.15
  11       27       13.5    0.08      -0.06         0.11      1.35     -0.7     0.62
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.      A
                                    Client            OG                                    Date          5/11/2017
                                    Project           GSM Network                           Designed by   M.Joe
                                                                                            Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m      KN.m
          m             m
  12       27          13.5         0.13      -0.04     0.11    1.15    -1.84     -1.15
  13       36              18       0.27      0.14      0.31    5.33    -3.82     -1.73
  14       36              18       0.35      0.09      0.31    4.88    -6.45     3.12
  15       36              18       0.27      -0.14     0.31    5.33    -3.82     1.73
  16       36              18       0.35      -0.09     0.31    4.88    -6.45     -3.12
  17       40              20       0.39      0.19      0.44    8.52    -6.55     -2.45
  18       40              20       0.49      0.11      0.44    7.94    -9.98     4.39
  19       40              20       0.39      -0.19     0.44    8.52    -6.55     2.45
  20       40              20       0.49      -0.11     0.44    7.94    -9.98     -4.39
       Total                        3.82          0     3.79    60.19   -60.82     0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 270
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra       C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2     mm                                 m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0        0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5     0       0.3     10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1       0       0.3     10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125    0       0.3     10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125    0       0.3     10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125    0       0.3     9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125    0       0.3     9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125    0       0.3     9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125    0       0.3     9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125    0       0.3     8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125    0       0.3     8.32      1.2    1.35    577.5   0.66
                                              Total                                               13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa     tiz       qz      θ      Force
                    m                m                   m2      m2      m2      mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.228      0      915.5    90     0.18
   2           36 To 40              38           1     1.608   0.456   0.456      0      901      90     0.35
   3           31.5 To 36           33.75         1     1.809   0.513   0.513      0      878.8    90     0.38
   4           27 To 31.5           29.25         1     1.809   0.513   0.513      0      852.7    90     0.37
   5           22.5 To 27           24.75         1     1.809   0.513   0.513      0      823.2    90     0.36
ASMTower 2018.4                 Job No.          40m Guyed Pole                       Rev. No.      A
                                Client           OG                                   Date          5/11/2017
                                Project          GSM Network                          Designed by   M.Joe
                                                                                      Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt    EPAa     tiz      qz      θ      Force
                m                   m               m2      m2      m2      mm      N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513   0.513     0      789.2    90     0.34
   7           13.5 To 18       15.75      1       1.809   0.513   0.513     0      748.5    90     0.33
   8           9 To 13.5        11.25      1       1.809   0.513   0.513     0      697.3    90      0.3
   9            4.5 To 9        6.75       1       1.809   0.513   0.513     0      626.2    90     0.27
  10            0 To 4.5        2.25       1       1.809   0.513   0.513     0      577.5    90     0.25
                                Total                              4.788     ---     ---     ---    3.14
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           41      0            0     0.18     7.27     0       -0.05
   2           38      0            0     0.35     13.27    0       -0.1
   3       33.75       0            0     0.38     12.93    0       -0.11
   4       29.25       0            0     0.37     10.88    0       -0.11
   5       24.75       0            0     0.36     8.88     0       -0.11
   6       20.25       0            0     0.34     6.97     0       -0.1
   7       15.75       0            0     0.33     5.14     0       -0.1
   8       11.25       0            0     0.3      3.42     0       -0.09
   9       6.75        0            0     0.27     1.84     0       -0.08
  10       2.25        0            0     0.25     0.57     0       -0.08
       Total           0            0     3.14     71.18    0       -0.94
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ      Force
            m          m                  m2        m2      m2     mm       N/m2    Deg      KN
   1           42      42           1    1.815     0.62    0.919     0      920.2   120     0.72
   2           42      42           1    1.815     0.62    0.919     0      920.2   120     0.72
   3           42      42           1    1.815     0.62    1.815     0      920.2    0      1.42
                            Total                          3.652    ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           42      0            0     0.72     30.18    0       -0.37
   2           42      0            0     0.72     30.18    0       0.37
   3           42      0            0     1.42     59.62    0        0
       Total           0            0     2.86    119.98    0        0
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                        Rev. No.       A
                              Client           OG                                    Date           5/11/2017
                              Project          GSM Network                           Designed by    M.Joe
                                                                                     Checked by     A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz        qz      θ      Force
           m         m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           42    42           1    0.034     0.358   0.277    0       920.2    120     0.22
   2           42    42           1    0.034     0.358   0.277    0       920.2    120     0.22
   3           42    42           1    0.034     0.358   0.034    0       920.2     0      0.03
                          Total                          0.587    ---       ---     ---    0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42    0            0     0.22     9.09     0      -0.07
   2           42    0            0     0.22     9.09     0       0.07
   3           42    0            0     0.03     1.11     0        0
       Total         0            0     0.46     19.28    0        0
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca       Cs      Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      910.8   240      -0.71    -0.44   -0.1     -2.49   -1.53   -0.87
   2           44    44       1200     1.131      0      929.3   120      -0.71    0.44     0.1     -0.64   0.39    0.11
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx     OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m     KN.m
   1           40   1.39          0     2.57      0      -0.87    0       102.87   -55.6    -1.68
   2           44   -0.35         0     0.66      0      0.11     0       28.86    15.6     0.32
       Total        1.04          0     3.23      ---     ---     ---     131.74   -40      -1.36
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz        qz      θ      Force
            m        m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           40    40           1      0       0.235   0.176    0       910.8    120     0.14
   2           44    44           1    0.034     0.234   0.184    0       929.3    120     0.15
                          Total                          0.36     ---       ---     ---    0.28
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40    0            0     0.14     5.45     0      -0.04
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44    0       0        0.15          6.39          0     0.05
       Total         0       0        0.28          11.84         0       0
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     77.18      577.5     0.08
  2            9     4.5         8            1.2           17.493     34.08      577.5     0.03
  3            9     4.5         8            1.2           17.493     102.82     577.5     0.08
  4            9     4.5         8            1.2           17.493     145.92     577.5     0.03
  5        18         9          8            1.2           23.431     80.46      665.3     0.12
  6        18         9          8            1.2           23.431      51.8      665.3     0.08
  7        18         9          8            1.2           23.431     99.54      665.3     0.12
  8        18         9          8            1.2           23.431     128.2      665.3     0.08
  9        27        13.5        8            1.2           30.887     82.78      724.6     0.18
  10       27        13.5        8            1.2           30.887     62.02      724.6     0.14
  11       27        13.5        8            1.2           30.887     97.22      724.6     0.18
  12       27        13.5        8            1.2           30.887     117.98     724.6     0.14
  13       36         18         16           1.2            39        84.29      769.9     0.49
  14       36         18         16           1.2            39        68.19      769.9     0.42
  15       36         18         16           1.2            39        95.71      769.9     0.49
  16       36         18         16           1.2            39        111.81     769.9     0.42
  17       40         20         20           1.2           42.72      84.79      787.1     0.68
  18       40         20         20           1.2           42.72      70.17      787.1     0.61
  19       40         20         20           1.2           42.72      95.21      787.1     0.68
  20       40         20         20           1.2           42.72      109.83     787.1     0.61
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy             Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN             KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01     0.01          0.08       0.33     0.13    -0.58
  2            9     4.5    0.01      0.02          0.01       -0.08   -0.08     0.09
  3            9     4.5    -0.01     -0.01         0.08       0.33     0.13     0.58
  4            9     4.5    0.01      -0.02         0.01       -0.08   -0.08    -0.09
  5        18        9      -0.01     0.02          0.12       1.07     0.23    -0.91
  6        18        9      0.01      0.05          0.06       0.21    -0.18     0.19
  7        18        9      -0.01     -0.02         0.12       1.07     0.23     0.91
  8        18        9      0.01      -0.05         0.06       0.21    -0.18    -0.19
  9        27       13.5    -0.01     0.02          0.18       2.37     0.29    -1.31
  10       27       13.5    0.01      0.07          0.13       1.22    -0.26     0.31
  11       27       13.5    -0.01     -0.02         0.18       2.37     0.29     1.31
ASMTower 2018.4                     Job No.           40m Guyed Pole                       Rev. No.      A
                                    Client            OG                                   Date          5/11/2017
                                    Project           GSM Network                          Designed by   M.Joe
                                                                                           Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m     KN.m
          m             m
  12       27          13.5         0.01      -0.07     0.13    1.22    -0.26    -0.31
  13       36              18       -0.02     0.04      0.48     8.6    0.65     -3.53
  14       36              18       0.02      0.16      0.39    5.93    -0.61    0.88
  15       36              18       -0.02     -0.04     0.48     8.6    0.65     3.53
  16       36              18       0.02      -0.16     0.39    5.93    -0.61    -0.88
  17       40              20       -0.02     0.06      0.68    13.44   0.84     -4.95
  18       40              20       0.02      0.2       0.57    9.94    -0.8     1.25
  19       40              20       -0.02     -0.06     0.68    13.44   0.84     4.95
  20       40              20       0.02      -0.2      0.57    9.94    -0.8     -1.25
       Total                        -0.02         0      5.4    86.04   0.45      0
Wind Calculation Of Basic Design Wind Speed 36.11 m/s Dir. 315
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra      C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2     mm                                m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0       0      10.54     0.6    0.45    927     0.35
               2           41        2        0.25       0.5     0      0.97    10.48     1.2     0.6    915.5   0.47
   2           1           38        4        0.25       1       0      0.97    10.4      1.2     1.2    901     0.92
   3           1       33.75         4.5      0.25      1.125    0      0.97    10.27     1.2    1.35    878.8   1.01
               2       29.25         4.5      0.25      1.125    0      0.97    10.11     1.2    1.35    852.7   0.98
   4           1       24.75         4.5      0.25      1.125    0      0.97    9.94      1.2    1.35    823.2   0.94
               2       20.25         4.5      0.25      1.125    0      0.97    9.73      1.2    1.35    789.2   0.91
   5           1       15.75         4.5      0.25      1.125    0      0.97    9.48      1.2    1.35    748.5   0.86
               2       11.25         4.5      0.25      1.125    0      0.97    9.15      1.2    1.35    697.3    0.8
   6           1       6.75          4.5      0.25      1.125    0      0.97    8.67      1.2    1.35    626.2   0.72
               2       2.25          4.5      0.25      1.125    0      0.97    8.32      1.2    1.35    577.5   0.66
                                              Total                                              13.05    ---    8.62
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa    tiz       qz      θ      Force
                    m                m                   m2      m2      m2     mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.516     0      915.5    45      0.4
   2           36 To 40              38           1     1.608   0.456   1.032     0      901      45     0.79
   3           31.5 To 36           33.75         1     1.809   0.513   1.161     0      878.8    45     0.87
   4           27 To 31.5           29.25         1     1.809   0.513   1.161     0      852.7    45     0.84
   5           22.5 To 27           24.75         1     1.809   0.513   1.161     0      823.2    45     0.81
ASMTower 2018.4                  Job No.          40m Guyed Pole                       Rev. No.      A
                                 Client           OG                                   Date          5/11/2017
                                 Project          GSM Network                          Designed by   M.Joe
                                                                                       Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                   Z     Ka       EPAn    EPAt    EPAa     tiz      qz      θ      Force
                m                    m               m2      m2      m2      mm      N/m2    Deg      KN
   6           18 To 22.5        20.25      1       1.809   0.513   1.161     0      789.2    45     0.78
   7           13.5 To 18        15.75      1       1.809   0.513   1.161     0      748.5    45     0.74
   8           9 To 13.5         11.25      1       1.809   0.513   1.161     0      697.3    45     0.69
   9            4.5 To 9         6.75       1       1.809   0.513   1.161     0      626.2    45     0.62
  10            0 To 4.5         2.25       1       1.809   0.513   1.161     0      577.5    45     0.57
                                 Total                              10.836    ---     ---     ---    7.11
Wind vector from transmission line clusters
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           41    -0.28           0     0.28     11.64   11.64    -0.09
   2           38    -0.56           0     0.56     21.24   21.24    -0.17
   3       33.75     -0.61           0     0.61     20.7    20.7     -0.18
   4       29.25      -0.6           0     0.6      17.4    17.4     -0.18
   5       24.75     -0.57           0     0.57     14.22   14.22    -0.17
   6       20.25     -0.55           0     0.55     11.15   11.15    -0.17
   7       15.75     -0.52           0     0.52     8.23    8.23     -0.16
   8       11.25     -0.49           0     0.49     5.47    5.47     -0.15
   9       6.75      -0.44           0     0.44     2.95    2.95     -0.13
  10       2.25       -0.4           0     0.4      0.91    0.91     -0.12
       Total         -5.03           0     5.03    113.91 113.91     -1.51
Wind forces from panel antenna
   #       Elev.       Z             Ka   EPAn      EPAt    EPAa     tiz      qz      θ      Force
            m          m                   m2        m2      m2      mm      N/m2    Deg      KN
   1           42      42            1    1.815     0.62     0.7      0      920.2    75     0.55
   2           42      42            1    1.815     0.62    1.735     0      920.2   165     1.36
   3           42      42            1    1.815     0.62    1.217     0      920.2    45     0.95
                             Total                          3.652    ---      ---     ---    2.86
Wind vector from panel antenna
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           42    -0.39           0     0.39     16.26   16.26    -0.31
   2           42    -0.96           0     0.96     40.3    40.3     0.21
   3           42    -0.67           0     0.67     28.28   28.28     0.4
       Total         -2.02           0     2.02     84.84   84.84    0.29
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                       Rev. No.        A
                              Client           OG                                   Date            5/11/2017
                              Project          GSM Network                          Designed by     M.Joe
                                                                                    Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
           m         m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           42    42           1    0.034     0.358   0.336    0       920.2    75      0.26
   2           42    42           1    0.034     0.358   0.056    0       920.2    165     0.04
   3           42    42           1    0.034     0.358   0.196    0       920.2    45      0.15
                          Total                          0.587    ---      ---     ---     0.46
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   -0.19         0     0.19      7.8     7.8     -0.1
   2           42   -0.03         0     0.03     1.29    1.29      0
   3           42   -0.11         0     0.11     4.55    4.55     0.04
       Total        -0.32         0     0.32     13.64   13.64   -0.05
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca      Cs       Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      910.8   285      0.47    -0.53    -0.05    1.66    -1.85   -0.39
   2           44    44       1200     1.131      0      929.3   165      -0.98    0.12    0.03     -0.88   0.11    0.04
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx    OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m    KN.m      KN.m
   1           40   -2.36         0     0.78      0      -0.39    0       31.11   94.42     -1.36
   2           44   -0.71         0     0.53      0      0.04     0       23.54   31.09     0.09
       Total        -3.07         0     1.31      ---     ---     ---     54.64   125.51    -1.27
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
            m        m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           40    40           1      0       0.235   0.219    0       910.8    75      0.17
   2           44    44           1    0.034     0.234   0.048    0       929.3    165     0.04
                          Total                          0.266    ---      ---     ---     0.21
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40   -0.12         0     0.12     4.79    4.79    -0.06
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44   -0.03    0        0.03          1.17      1.17       0
       Total        -0.15    0        0.15          5.96      5.96     -0.06
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd            Lg          θg        qz       Fw
          Elev.     Elev.      mm                           m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     115.39     577.5     0.07
  2            9     4.5         8            1.2          17.493     42.05      577.5     0.04
  3            9     4.5         8            1.2          17.493     64.61      577.5     0.07
  4            9     4.5         8            1.2          17.493     137.95     577.5     0.04
  5        18         9          8            1.2          23.431     108.67     665.3     0.11
  6        18         9          8            1.2          23.431     56.33      665.3     0.09
  7        18         9          8            1.2          23.431     71.33      665.3     0.11
  8        18         9          8            1.2          23.431     123.67     665.3     0.09
  9        27        13.5        8            1.2          30.887     104.05     724.6     0.17
  10       27        13.5        8            1.2          30.887     65.13      724.6     0.15
  11       27        13.5        8            1.2          30.887     75.95      724.6     0.17
  12       27        13.5        8            1.2          30.887     114.87     724.6     0.15
  13       36         18         16           1.2           39        101.09     769.9     0.47
  14       36         18         16           1.2           39        70.54      769.9     0.44
  15       36         18         16           1.2           39        78.91      769.9     0.47
  16       36         18         16           1.2           39        109.46     769.9     0.44
  17       40         20         20           1.2          42.72      100.11     787.1     0.66
  18       40         20         20           1.2          42.72       72.3      787.1     0.62
  19       40         20         20           1.2          42.72      79.89      787.1     0.66
  20       40         20         20           1.2          42.72      107.7      787.1     0.62
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.03     -0.02         0.06      0.3       0      -0.48
  2            9     4.5    -0.03     0.02          0.01      -0.13    0.09    -0.21
  3            9     4.5    -0.03     0.02          0.06      0.3       0       0.48
  4            9     4.5    -0.03     -0.02         0.01      -0.13    0.09     0.21
  5        18        9      -0.06     -0.03         0.09      0.88     0.34    -0.78
  6        18        9      -0.07     0.05          0.04      0.02     0.5      -0.4
  7        18        9      -0.06     0.03          0.09      0.88     0.34     0.78
  8        18        9      -0.07     -0.05         0.04      0.02     0.5      0.4
  9        27       13.5    -0.11     -0.04         0.13      1.84     1.15    -1.15
  10       27       13.5    -0.11     0.06          0.08      0.7      1.35    -0.62
  11       27       13.5    -0.11     0.04          0.13      1.84     1.15     1.15
ASMTower 2018.4                     Job No.           40m Guyed Pole                       Rev. No.       A
                                    Client            OG                                   Date           5/11/2017
                                    Project           GSM Network                          Designed by    M.Joe
                                                                                           Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m     KN.m
          m             m
  12       27          13.5         -0.11     -0.06     0.08     0.7    1.35     0.62
  13       36              18       -0.31     -0.09     0.35    6.45    4.88    -3.12
  14       36              18       -0.31     0.14      0.27    3.82    5.33    -1.73
  15       36              18       -0.31     0.09      0.35    6.45    4.88     3.12
  16       36              18       -0.31     -0.14     0.27    3.82    5.33     1.73
  17       40              20       -0.44     -0.11     0.49    9.98    7.94    -4.39
  18       40              20       -0.44     0.19      0.39    6.55    8.52    -2.45
  19       40              20       -0.44     0.11      0.49    9.98    7.94     4.39
  20       40              20       -0.44     -0.19     0.39    6.55    8.52     2.45
       Total                        -3.79         0     3.82    60.82   60.19     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 0
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra      C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2     mm                                m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0       0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5     0      1.07    7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1       0      1.07     7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125    0      1.07    7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125    0      1.07     7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125    0      1.07    6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125    0      1.07    6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125    0      1.07    6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125    0      1.07    6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125    0      1.07     6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125    0      1.07    5.76      1.2     1.35    276.8   0.32
                                              Total                                              13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa    tiz       qz       θ      Force
                    m                m                   m2      m2      m2     mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.804    0       438.8     0       0.3
   2           36 To 40              38           1     1.608   0.456   1.608    0       431.8     0      0.59
   3           31.5 To 36           33.75         1     1.809   0.513   1.809    0       421.2     0      0.65
   4           27 To 31.5           29.25         1     1.809   0.513   1.809    0       408.7     0      0.63
   5           22.5 To 27           24.75         1     1.809   0.513   1.809    0       394.6     0      0.61
ASMTower 2018.4                  Job No.          40m Guyed Pole                      Rev. No.      A
                                 Client           OG                                  Date          5/11/2017
                                 Project          GSM Network                         Designed by   M.Joe
                                                                                      Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                   Z     Ka       EPAn    EPAt    EPAa     tiz     qz      θ      Force
                m                    m               m2      m2      m2      mm     N/m2    Deg      KN
   6           18 To 22.5        20.25     1        1.809   0.513   1.809     0     378.3    0      0.58
   7           13.5 To 18        15.75     1        1.809   0.513   1.809     0     358.8    0      0.55
   8           9 To 13.5         11.25     1        1.809   0.513   1.809     0     334.2    0      0.51
   9            4.5 To 9         6.75      1        1.809   0.513   1.809     0     300.1    0      0.46
  10            0 To 4.5         2.25      1        1.809   0.513   1.809     0     276.8    0      0.43
                                 Total                              16.884    ---    ---     ---    5.31
Wind vector from transmission line clusters
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           41     -0.3           0     0         0      12.3       0
   2           38    -0.59           0     0         0      22.43      0
   3       33.75     -0.65           0     0         0      21.86      0
   4       29.25     -0.63           0     0         0      18.38      0
   5       24.75     -0.61           0     0         0      15.02      0
   6       20.25     -0.58           0     0         0      11.78      0
   7       15.75     -0.55           0     0         0      8.69       0
   8       11.25     -0.51           0     0         0      5.78       0
   9       6.75      -0.46           0     0         0      3.12       0
  10       2.25      -0.43           0     0         0      0.96       0
       Total         -5.31           0     0         0      120.3      0
Wind forces from panel antenna
   #       Elev.       Z             Ka   EPAn      EPAt    EPAa     tiz      qz     θ      Force
            m          m                   m2        m2      m2      mm      N/m2   Deg      KN
   1           42      42            1    1.815     0.62    1.516     0      441     30     0.57
   2           42      42            1    1.815     0.62    1.516     0      441    150     0.57
   3           42      42            1    1.815     0.62    0.62      0      441     90     0.23
                             Total                          3.652    ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx             Fy    Fz       OTMx    OTMz    Torque
            m         KN             KN    KN       KN.m    KN.m     KN.m
   1           42    -0.57           0     0         0      23.87    -0.17
   2           42    -0.57           0     0         0      23.87    -0.17
   3           42    -0.23           0     0         0      9.76     0.14
       Total         -1.37           0     0         0      57.5      -0.2
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                        Rev. No.       A
                              Client           OG                                    Date           5/11/2017
                              Project          GSM Network                           Designed by    M.Joe
                                                                                     Checked by     A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
           m         m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           42    42           1    0.034     0.358   0.115    0        441      30     0.04
   2           42    42           1    0.034     0.358   0.115    0        441     150     0.04
   3           42    42           1    0.034     0.358   0.358    0        441      90     0.13
                          Total                          0.587    ---      ---      ---    0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   -0.04         0      0        0      1.81    -0.01
   2           42   -0.04         0      0        0      1.81    -0.01
   3           42   -0.13         0      0        0      5.63     0.05
       Total        -0.22         0      0        0      9.24     0.04
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca       Cs      Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      436.5   330      1.21     -0.23   0.05     2.03    -0.39   0.21
   2           44    44       1200     1.131      0      445.4   210      -0.96    -0.18   -0.06    -0.41   -0.08   -0.03
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx     OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m     KN.m
   1           40   -1.96         0    -0.68      0      0.21     0       -27.02   78.28     0
   2           44   -0.39         0     0.14      0      -0.03    0       6.15     17.27    -0.07
       Total        -2.35         0    -0.54      ---     ---     ---     -20.88   95.55    -0.07
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
            m        m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           40    40           1      0       0.244   0.061    0       436.5     30     0.02
   2           44    44           1    0.034     0.244   0.087    0       445.4    150     0.03
                          Total                          0.148    ---      ---      ---    0.06
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40   -0.02         0      0        0      0.91      0
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   -0.03    0         0             0         1.44     -0.01
       Total        -0.06    0         0             0         2.35     -0.01
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     145.92     276.8     0.01
  2            9     4.5         8            1.2           17.493     77.18      276.8     0.04
  3            9     4.5         8            1.2           17.493     34.08      276.8     0.01
  4            9     4.5         8            1.2           17.493     102.82     276.8     0.04
  5        18         9          8            1.2           23.431     128.2      318.9     0.04
  6        18         9          8            1.2           23.431     80.46      318.9     0.06
  7        18         9          8            1.2           23.431      51.8      318.9     0.04
  8        18         9          8            1.2           23.431     99.54      318.9     0.06
  9        27        13.5        8            1.2           30.887     117.98     347.3     0.07
  10       27        13.5        8            1.2           30.887     82.78      347.3     0.09
  11       27        13.5        8            1.2           30.887     62.02      347.3     0.07
  12       27        13.5        8            1.2           30.887     97.22      347.3     0.09
  13       36         18         16           1.2            39        111.81     369       0.2
  14       36         18         16           1.2            39        84.29      369       0.23
  15       36         18         16           1.2            39        68.19      369       0.2
  16       36         18         16           1.2            39        95.71      369       0.23
  17       40         20         20           1.2           42.72      109.83     377.3     0.29
  18       40         20         20           1.2           42.72      84.79      377.3     0.33
  19       40         20         20           1.2           42.72      70.17      377.3     0.29
  20       40         20         20           1.2           42.72      95.21      377.3     0.33
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01     -0.01          0         0.04    -0.04    -0.04
  2            9     4.5    -0.04      0            -0.01      -0.06    0.16    -0.28
  3            9     4.5    -0.01     0.01           0         0.04    -0.04     0.04
  4            9     4.5    -0.04      0            -0.01      -0.06    0.16     0.28
  5        18        9      -0.03     -0.02          0         0.09     0.1     -0.09
  6        18        9      -0.06     0.01          -0.01      -0.11    0.51    -0.44
  7        18        9      -0.03     0.02           0         0.09     0.1      0.09
  8        18        9      -0.06     -0.01         -0.01      -0.11    0.51     0.44
  9        27       13.5    -0.06     -0.03          0         0.12     0.58    -0.15
  10       27       13.5    -0.09     0.01          -0.01      -0.14    1.14    -0.63
  11       27       13.5    -0.06     0.03           0         0.12     0.58     0.15
ASMTower 2018.4                     Job No.           40m Guyed Pole                       Rev. No.       A
                                    Client            OG                                   Date           5/11/2017
                                    Project           GSM Network                          Designed by    M.Joe
                                                                                           Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m     KN.m
          m             m
  12       27          13.5         -0.09     -0.01     -0.01   -0.14   1.14     0.63
  13       36              18       -0.19     -0.07     0.01    0.29    2.84    -0.42
  14       36              18       -0.23     0.02      -0.01   -0.31   4.12    -1.69
  15       36              18       -0.19     0.07      0.01    0.29    2.84     0.42
  16       36              18       -0.23     -0.02     -0.01   -0.31   4.12     1.69
  17       40              20       -0.27     -0.1      0.01    0.38    4.76     -0.6
  18       40              20       -0.32     0.03      -0.01   -0.4    6.44    -2.37
  19       40              20       -0.27     0.1       0.01    0.38    4.76     0.6
  20       40              20       -0.32     -0.03     -0.01   -0.4    6.44     2.37
       Total                        -2.59         0     -0.01   -0.22   41.24     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 45
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra      C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2     mm                                m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0       0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5     0      0.97    7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1       0      0.97     7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125    0      0.97    7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125    0      0.97     7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125    0      0.97    6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125    0      0.97    6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125    0      0.97    6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125    0      0.97    6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125    0      0.97     6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125    0      0.97    5.76      1.2     1.35    276.8   0.32
                                              Total                                              13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa    tiz       qz       θ      Force
                    m                m                   m2      m2      m2     mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.516    0       438.8    45      0.19
   2           36 To 40              38           1     1.608   0.456   1.032    0       431.8    45      0.38
   3           31.5 To 36           33.75         1     1.809   0.513   1.161    0       421.2    45      0.42
   4           27 To 31.5           29.25         1     1.809   0.513   1.161    0       408.7    45       0.4
   5           22.5 To 27           24.75         1     1.809   0.513   1.161    0       394.6    45      0.39
ASMTower 2018.4                 Job No.          40m Guyed Pole                      Rev. No.      A
                                Client           OG                                  Date          5/11/2017
                                Project          GSM Network                         Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt    EPAa     tiz     qz      θ      Force
                m                   m               m2      m2      m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513   1.161     0     378.3    45     0.37
   7           13.5 To 18       15.75     1        1.809   0.513   1.161     0     358.8    45     0.35
   8           9 To 13.5        11.25     1        1.809   0.513   1.161     0     334.2    45     0.33
   9            4.5 To 9        6.75      1        1.809   0.513   1.161     0     300.1    45      0.3
  10            0 To 4.5        2.25      1        1.809   0.513   1.161     0     276.8    45     0.27
                                Total                              10.836    ---    ---     ---    3.41
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           41    -0.14          0    -0.14     -5.58   5.58     0.04
   2           38    -0.27          0    -0.27    -10.18   10.18    0.08
   3       33.75     -0.29          0    -0.29     -9.92   9.92     0.09
   4       29.25     -0.29          0    -0.29     -8.34   8.34     0.09
   5       24.75     -0.28          0    -0.28     -6.81   6.81     0.08
   6       20.25     -0.26          0    -0.26     -5.34   5.34     0.08
   7       15.75     -0.25          0    -0.25     -3.94   3.94     0.08
   8       11.25     -0.23          0    -0.23     -2.62   2.62     0.07
   9       6.75      -0.21          0    -0.21     -1.41   1.41     0.06
  10       2.25      -0.19          0    -0.19     -0.43   0.43     0.06
       Total         -2.41          0    -2.41    -54.59   54.59    0.72
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz      qz     θ      Force
            m          m                  m2        m2      m2      mm      N/m2   Deg      KN
   1           42      42           1    1.815     0.62    1.735     0      441     15     0.65
   2           42      42           1    1.815     0.62     0.7      0      441    105     0.26
   3           42      42           1    1.815     0.62    1.217     0      441    135     0.46
                            Total                          3.652    ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           42    -0.46          0    -0.46    -19.31   19.31     0.1
   2           42    -0.19          0    -0.19     -7.79   7.79     -0.15
   3           42    -0.32          0    -0.32    -13.55   13.55    0.19
       Total         -0.97          0    -0.97    -40.66   40.66    0.14
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                        Rev. No.       A
                              Client           OG                                    Date           5/11/2017
                              Project          GSM Network                           Designed by    M.Joe
                                                                                     Checked by     A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
           m         m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           42    42           1    0.034     0.358   0.056    0        441      15     0.02
   2           42    42           1    0.034     0.358   0.336    0        441     105     0.13
   3           42    42           1    0.034     0.358   0.196    0        441     135     0.07
                          Total                          0.587    ---      ---      ---    0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   -0.01         0    -0.01     -0.62   0.62      0
   2           42   -0.09         0    -0.09     -3.74   3.74    -0.05
   3           42   -0.05         0    -0.05     -2.18   2.18     0.02
       Total        -0.16         0    -0.16     -6.54   6.54    -0.02
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca       Cs      Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      436.5    15      1.26     0.14    -0.04    2.11    0.23    -0.15
   2           44    44       1200     1.131      0      445.4   255      -0.44    -0.57   -0.11    -0.19   -0.24   -0.06
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx     OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m     KN.m
   1           40   -1.71         0    -1.25      0      -0.15    0       -50.11   68.44    -0.03
   2           44   -0.28         0    -0.12      0      -0.06    0       -5.08    12.54    -0.19
       Total         -2           0    -1.37      ---     ---     ---     -55.2    80.97    -0.21
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ      Force
            m        m                  m2        m2      m2     mm       N/m2     Deg      KN
   1           40    40           1      0       0.244   0.016    0       436.5     15     0.01
   2           44    44           1    0.034     0.244   0.23     0       445.4    105     0.09
                          Total                          0.246    ---      ---      ---    0.09
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40    0            0      0       -0.17   0.17      0
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   -0.06    0        -0.06         -2.71      2.71     -0.03
       Total        -0.07    0        -0.07         -2.88      2.88     -0.03
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd             Lg          θg        qz       Fw
          Elev.     Elev.      mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     137.95     276.8     0.02
  2            9     4.5         8            1.2           17.493     115.39     276.8     0.03
  3            9     4.5         8            1.2           17.493     42.05      276.8     0.02
  4            9     4.5         8            1.2           17.493     64.61      276.8     0.03
  5        18         9          8            1.2           23.431     123.67     318.9     0.04
  6        18         9          8            1.2           23.431     108.67     318.9     0.05
  7        18         9          8            1.2           23.431     56.33      318.9     0.04
  8        18         9          8            1.2           23.431     71.33      318.9     0.05
  9        27        13.5        8            1.2           30.887     114.87     347.3     0.07
  10       27        13.5        8            1.2           30.887     104.05     347.3     0.08
  11       27        13.5        8            1.2           30.887     65.13      347.3     0.07
  12       27        13.5        8            1.2           30.887     75.95      347.3     0.08
  13       36         18         16           1.2            39        109.46     369       0.21
  14       36         18         16           1.2            39        101.09     369       0.23
  15       36         18         16           1.2            39        70.54      369       0.21
  16       36         18         16           1.2            39        78.91      369       0.23
  17       40         20         20           1.2           42.72      107.7      377.3     0.3
  18       40         20         20           1.2           42.72      100.11     377.3     0.32
  19       40         20         20           1.2           42.72       72.3      377.3     0.3
  20       40         20         20           1.2           42.72      79.89      377.3     0.32
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5     0        -0.01         -0.01      -0.04   -0.06     0.1
  2            9     4.5    -0.03     -0.01         -0.01         0     0.14    -0.23
  3            9     4.5     0        0.01          -0.01      -0.04   -0.06     -0.1
  4            9     4.5    -0.03     0.01          -0.01         0     0.14     0.23
  5        18        9      -0.02     -0.02         -0.03      -0.24    0.01     0.19
  6        18        9      -0.04     -0.01         -0.03      -0.16    0.42    -0.38
  7        18        9      -0.02     0.02          -0.03      -0.24    0.01    -0.19
  8        18        9      -0.04     0.01          -0.03      -0.16    0.42     0.38
  9        27       13.5    -0.04     -0.03         -0.05      -0.64    0.34     0.3
  10       27       13.5    -0.06     -0.02         -0.05      -0.55    0.88    -0.55
  11       27       13.5    -0.04     0.03          -0.05      -0.64    0.34     -0.3
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.       A
                                    Client            OG                                    Date           5/11/2017
                                    Project           GSM Network                           Designed by    M.Joe
                                                                                            Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m     KN.m
          m             m
  12       27          13.5         -0.06     0.02      -0.05   -0.55    0.88     0.55
  13       36              18       -0.13     -0.07     -0.15   -2.55    1.83     0.83
  14       36              18       -0.17     -0.04     -0.15   -2.34    3.09     -1.5
  15       36              18       -0.13     0.07      -0.15   -2.55    1.83    -0.83
  16       36              18       -0.17     0.04      -0.15   -2.34    3.09     1.5
  17       40              20       -0.19     -0.09     -0.21   -4.08    3.14     1.17
  18       40              20       -0.23     -0.05     -0.21   -3.81    4.78     -2.1
  19       40              20       -0.19     0.09      -0.21   -4.08    3.14    -1.17
  20       40              20       -0.23     0.05      -0.21   -3.81    4.78     2.1
       Total                        -1.83         0     -1.82   -28.85   29.15     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 90
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra      C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2      mm                                m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0       0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5      0       0.3    7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1        0       0.3     7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125     0       0.3    7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125     0       0.3     7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125     0       0.3    6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125     0       0.3    6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125     0       0.3    6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125     0       0.3    6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125     0       0.3     6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125     0       0.3    5.76      1.2     1.35    276.8   0.32
                                              Total                                               13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa    tiz       qz       θ      Force
                    m                m                   m2      m2       m2     mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228    0.228    0       438.8    90      0.09
   2           36 To 40              38           1     1.608   0.456    0.456    0       431.8    90      0.17
   3           31.5 To 36           33.75         1     1.809   0.513    0.513    0       421.2    90      0.18
   4           27 To 31.5           29.25         1     1.809   0.513    0.513    0       408.7    90      0.18
   5           22.5 To 27           24.75         1     1.809   0.513    0.513    0       394.6    90      0.17
ASMTower 2018.4                 Job No.          40m Guyed Pole                      Rev. No.      A
                                Client           OG                                  Date          5/11/2017
                                Project          GSM Network                         Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt    EPAa     tiz     qz      θ      Force
                m                   m               m2      m2      m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513   0.513     0     378.3    90     0.16
   7           13.5 To 18       15.75     1        1.809   0.513   0.513     0     358.8    90     0.16
   8           9 To 13.5        11.25     1        1.809   0.513   0.513     0     334.2    90     0.15
   9            4.5 To 9        6.75      1        1.809   0.513   0.513     0     300.1    90     0.13
  10            0 To 4.5        2.25      1        1.809   0.513   0.513     0     276.8    90     0.12
                                Total                              4.788     ---    ---     ---    1.51
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           41      0            0    -0.09     -3.49    0       0.03
   2           38      0            0    -0.17     -6.36    0       0.05
   3       33.75       0            0    -0.18     -6.2     0       0.06
   4       29.25       0            0    -0.18     -5.21    0       0.05
   5       24.75       0            0    -0.17     -4.26    0       0.05
   6       20.25       0            0    -0.16     -3.34    0       0.05
   7       15.75       0            0    -0.16     -2.46    0       0.05
   8       11.25       0            0    -0.15     -1.64    0       0.04
   9       6.75        0            0    -0.13     -0.88    0       0.04
  10       2.25        0            0    -0.12     -0.27    0       0.04
       Total           0            0    -1.51    -34.12    0       0.45
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz     θ      Force
            m          m                  m2        m2      m2     mm       N/m2   Deg      KN
   1           42      42           1    1.815     0.62    0.919     0      441     60     0.34
   2           42      42           1    1.815     0.62    0.919     0      441     60     0.34
   3           42      42           1    1.815     0.62    1.815     0      441    180     0.68
                            Total                          3.652    ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           42      0            0    -0.34    -14.47    0       0.18
   2           42      0            0    -0.34    -14.47    0       -0.18
   3           42      0            0    -0.68    -28.57    0        0
       Total           0            0    -1.37     -57.5    0        0
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                        Rev. No.        A
                              Client           OG                                    Date            5/11/2017
                              Project          GSM Network                           Designed by     M.Joe
                                                                                     Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ       Force
           m         m                  m2        m2      m2     mm       N/m2     Deg       KN
   1           42    42           1    0.034     0.358   0.277    0        441      60       0.1
   2           42    42           1    0.034     0.358   0.277    0        441      60       0.1
   3           42    42           1    0.034     0.358   0.034    0        441      180     0.01
                          Total                          0.587    ---      ---      ---     0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42    0            0     -0.1     -4.35    0       0.03
   2           42    0            0     -0.1     -4.35    0      -0.03
   3           42    0            0    -0.01     -0.53    0        0
       Total         0            0    -0.22     -9.24    0        0
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca       Cs       Cm      Fa     Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                 KN     KN      KN
   1           40    40       2400     4.524      0      436.5    60      0.95     0.37     -0.01    1.59   0.62    -0.03
   2           44    44       1200     1.131      0      445.4   300      0.95     -0.37    0.01     0.4    -0.16    0
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx     OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m      KN.m
   1           40   -1.07         0    -1.33      0      -0.03    0       -53.09   42.64     0.29
   2           44   0.27          0    -0.34      0       0       0       -14.9    -11.96    -0.08
       Total        -0.79         0    -1.67      ---     ---     ---     -67.98   30.68     0.21
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz       θ       Force
            m        m                  m2        m2      m2     mm       N/m2     Deg       KN
   1           40    40           1      0       0.244   0.183    0       436.5     60      0.07
   2           44    44           1    0.034     0.244   0.192    0       445.4     60      0.07
                          Total                          0.375    ---      ---      ---     0.14
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40    0            0    -0.07     -2.72    0       0.02
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44    0       0        -0.07         -3.19         0     -0.02
       Total         0       0        -0.14         -5.91         0       0
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd             Lg          θg        qz       Fw
          Elev.     Elev.     mm                             m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     102.82     276.8     0.04
  2            9     4.5         8            1.2           17.493     145.92     276.8     0.01
  3            9     4.5         8            1.2           17.493     77.18      276.8     0.04
  4            9     4.5         8            1.2           17.493     34.08      276.8     0.01
  5        18         9          8            1.2           23.431     99.54      318.9     0.06
  6        18         9          8            1.2           23.431     128.2      318.9     0.04
  7        18         9          8            1.2           23.431     80.46      318.9     0.06
  8        18         9          8            1.2           23.431      51.8      318.9     0.04
  9        27        13.5        8            1.2           30.887     97.22      347.3     0.09
  10       27        13.5        8            1.2           30.887     117.98     347.3     0.07
  11       27        13.5        8            1.2           30.887     82.78      347.3     0.09
  12       27        13.5        8            1.2           30.887     62.02      347.3     0.07
  13       36         18         16           1.2            39        95.71      369       0.23
  14       36         18         16           1.2            39        111.81     369       0.2
  15       36         18         16           1.2            39        84.29      369       0.23
  16       36         18         16           1.2            39        68.19      369       0.2
  17       40         20         20           1.2           42.72      95.21      377.3     0.33
  18       40         20         20           1.2           42.72      109.83     377.3     0.29
  19       40         20         20           1.2           42.72      84.79      377.3     0.33
  20       40         20         20           1.2           42.72      70.17      377.3     0.29
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01       0            -0.04      -0.16   -0.06     0.28
  2            9     4.5     0        -0.01         -0.01      0.04     0.04    -0.04
  3            9     4.5    0.01       0            -0.04      -0.16   -0.06    -0.28
  4            9     4.5     0        0.01          -0.01      0.04     0.04     0.04
  5        18        9      0.01      -0.01         -0.06      -0.51   -0.11     0.44
  6        18        9       0        -0.02         -0.03      -0.1     0.09    -0.09
  7        18        9      0.01      0.01          -0.06      -0.51   -0.11    -0.44
  8        18        9       0        0.02          -0.03      -0.1     0.09     0.09
  9        27       13.5    0.01      -0.01         -0.09      -1.14   -0.14     0.63
  10       27       13.5     0        -0.03         -0.06      -0.58    0.12    -0.15
  11       27       13.5    0.01      0.01          -0.09      -1.14   -0.14    -0.63
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.       A
                                    Client            OG                                    Date           5/11/2017
                                    Project           GSM Network                           Designed by    M.Joe
                                                                                            Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m     KN.m
          m             m
  12       27          13.5          0        0.03      -0.06   -0.58    0.12     0.15
  13       36              18       0.01      -0.02     -0.23   -4.12    -0.31    1.69
  14       36              18       -0.01     -0.07     -0.19   -2.84    0.29    -0.42
  15       36              18       0.01      0.02      -0.23   -4.12    -0.31   -1.69
  16       36              18       -0.01     0.07      -0.19   -2.84    0.29     0.42
  17       40              20       0.01      -0.03     -0.32   -6.44    -0.4     2.37
  18       40              20       -0.01     -0.1      -0.27   -4.76    0.38     -0.6
  19       40              20       0.01      0.03      -0.32   -6.44    -0.4    -2.37
  20       40              20       -0.01     0.1       -0.27   -4.76    0.38     0.6
       Total                        0.01          0     -2.59   -41.24   -0.22     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 135
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra      C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2      mm                                m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0       0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5      0      0.84    7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1        0      0.84     7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125     0      0.84    7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125     0      0.84     7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125     0      0.84    6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125     0      0.84    6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125     0      0.84    6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125     0      0.84    6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125     0      0.84     6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125     0      0.84    5.76      1.2     1.35    276.8   0.32
                                              Total                                               13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa    tiz       qz       θ      Force
                    m                m                   m2      m2       m2     mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228    0.443    0       438.8    135     0.17
   2           36 To 40              38           1     1.608   0.456    0.886    0       431.8    135     0.33
   3           31.5 To 36           33.75         1     1.809   0.513    0.996    0       421.2    135     0.36
   4           27 To 31.5           29.25         1     1.809   0.513    0.996    0       408.7    135     0.35
   5           22.5 To 27           24.75         1     1.809   0.513    0.996    0       394.6    135     0.33
ASMTower 2018.4                 Job No.          40m Guyed Pole                       Rev. No.      A
                                Client           OG                                   Date          5/11/2017
                                Project          GSM Network                          Designed by   M.Joe
                                                                                      Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz     qz      θ      Force
                m                   m               m2      m2       m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513    0.996     0     378.3   135     0.32
   7           13.5 To 18       15.75      1       1.809   0.513    0.996     0     358.8   135      0.3
   8           9 To 13.5        11.25      1       1.809   0.513    0.996     0     334.2   135     0.28
   9            4.5 To 9        6.75       1       1.809   0.513    0.996     0     300.1   135     0.25
  10            0 To 4.5        2.25       1       1.809   0.513    0.996     0     276.8   135     0.23
                                Total                                9.3      ---    ---     ---    2.92
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41     0.12          0    -0.12     -4.79   -4.79     0.04
   2           38     0.23          0    -0.23     -8.74   -8.74     0.07
   3       33.75      0.25          0    -0.25     -8.51   -8.51     0.08
   4       29.25      0.24          0    -0.24     -7.16   -7.16     0.07
   5       24.75      0.24          0    -0.24     -5.85   -5.85     0.07
   6       20.25      0.23          0    -0.23     -4.59   -4.59     0.07
   7       15.75      0.21          0    -0.21     -3.38   -3.38     0.06
   8       11.25      0.2           0     -0.2     -2.25   -2.25     0.06
   9       6.75       0.18          0    -0.18     -1.21   -1.21     0.05
  10       2.25       0.17          0    -0.17     -0.37   -0.37     0.05
       Total          2.07          0    -2.07    -46.85   -46.85    0.62
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz     θ      Force
            m          m                  m2        m2      m2      mm       N/m2   Deg      KN
   1           42      42           1    1.815     0.62     0.7       0      441    105     0.26
   2           42      42           1    1.815     0.62    1.735      0      441     15     0.65
   3           42      42           1    1.815     0.62    1.217      0      441    135     0.46
                            Total                          3.652     ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42     0.19          0    -0.19     -7.79   -7.79     0.15
   2           42     0.46          0    -0.46    -19.31   -19.31    -0.1
   3           42     0.32          0    -0.32    -13.55   -13.55    -0.19
       Total          0.97          0    -0.97    -40.66   -40.66    -0.14
Wind forces from mounts of panel antenna
ASMTower 2018.4              Job No.          40m Guyed Pole                        Rev. No.        A
                             Client           OG                                    Date            5/11/2017
                             Project          GSM Network                           Designed by     M.Joe
                                                                                    Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z           Ka   EPAn      EPAt    EPAa    tiz       qz       θ       Force
           m         m                 m2        m2      m2     mm       N/m2     Deg       KN
   1           42   42           1    0.034     0.358   0.336    0        441      105     0.13
   2           42   42           1    0.034     0.358   0.056    0        441      15      0.02
   3           42   42           1    0.034     0.358   0.196    0        441      135     0.07
                         Total                          0.587    ---      ---      ---     0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz    Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m
   1           42   0.09         0    -0.09     -3.74   -3.74    0.05
   2           42   0.01         0    -0.01     -0.62   -0.62     0
   3           42   0.05         0    -0.05     -2.18   -2.18   -0.02
       Total        0.16         0    -0.16     -6.54   -6.54    0.02
Wind forces from MW dishes
   #       Elev.     Z       O.D.      Area     tiz      qz      θ        Ca       Cs       Cm      Fa      Fs      Mm
            m        m       mm         m2      mm      N/m2    Deg                                 KN      KN      KN
   1           40   40       2400     4.524      0      436.5   105      -0.44    0.57     0.11     -0.74   0.95    0.46
   2           44   44       1200     1.131      0      445.4   345      1.26     -0.14    0.04     0.54    -0.06   0.02
Wind vectors from MW dishes
   #       Elev.    Fx           Fy    Fz        Mx      My      Mz      OTMx     OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m    KN.m     KN.m     KN.m      KN.m
   1           40   1.12         0    -0.45      0      0.46     0       -18.12   -44.69    0.96
   2           44   0.44         0    -0.32      0      0.02     0       -14.06   -19.2     -0.01
       Total        1.55         0    -0.77      ---     ---     ---     -32.18   -63.89    0.94
Wind forces from mounts Of MW dishes
   #       Elev.     Z           Ka   EPAn      EPAt    EPAa    tiz       qz       θ       Force
            m        m                 m2        m2      m2     mm       N/m2     Deg       KN
   1           40   40           1      0       0.244   0.228    0       436.5     105     0.08
   2           44   44           1    0.034     0.244   0.048    0       445.4     15      0.02
                         Total                          0.276    ---      ---      ---      0.1
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz    Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m
   1           40   0.06         0    -0.06     -2.39   -2.39    0.03
ASMTower 2018.4             Job No.           40m Guyed Pole                              Rev. No.      A
                            Client            OG                                          Date          5/11/2017
                            Project           GSM Network                                 Designed by   M.Joe
                                                                                          Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx       OTMz     Torque
           m         KN     KN        KN           KN.m       KN.m      KN.m
   2           44   0.01     0        -0.01         -0.57      -0.57      0
       Total        0.07     0        -0.07         -2.96      -2.96    0.03
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd             Lg          θg        qz       Fw
          Elev.     Elev.     mm                             m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2           17.493     64.61      276.8     0.03
  2            9     4.5         8            1.2           17.493     137.95     276.8     0.02
  3            9     4.5         8            1.2           17.493     115.39     276.8     0.03
  4            9     4.5         8            1.2           17.493     42.05      276.8     0.02
  5        18         9          8            1.2           23.431     71.33      318.9     0.05
  6        18         9          8            1.2           23.431     123.67     318.9     0.04
  7        18         9          8            1.2           23.431     108.67     318.9     0.05
  8        18         9          8            1.2           23.431     56.33      318.9     0.04
  9        27        13.5        8            1.2           30.887     75.95      347.3     0.08
  10       27        13.5        8            1.2           30.887     114.87     347.3     0.07
  11       27        13.5        8            1.2           30.887     104.05     347.3     0.08
  12       27        13.5        8            1.2           30.887     65.13      347.3     0.07
  13       36         18         16           1.2            39        78.91      369       0.23
  14       36         18         16           1.2            39        109.46     369       0.21
  15       36         18         16           1.2            39        101.09     369       0.23
  16       36         18         16           1.2            39        70.54      369       0.21
  17       40         20         20           1.2           42.72      79.89      377.3     0.32
  18       40         20         20           1.2           42.72      107.7      377.3     0.3
  19       40         20         20           1.2           42.72      100.11     377.3     0.32
  20       40         20         20           1.2           42.72       72.3      377.3     0.3
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz        OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN        KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01      0.01          -0.03      -0.14     0       0.23
  2            9     4.5    0.01      -0.01          0         0.06    -0.04     0.1
  3            9     4.5    0.01      -0.01         -0.03      -0.14     0      -0.23
  4            9     4.5    0.01      0.01           0         0.06    -0.04     -0.1
  5        18        9      0.03      0.01          -0.04      -0.42   -0.16     0.38
  6        18        9      0.03      -0.02         -0.02      -0.01   -0.24     0.19
  7        18        9      0.03      -0.01         -0.04      -0.42   -0.16    -0.38
  8        18        9      0.03      0.02          -0.02      -0.01   -0.24    -0.19
  9        27       13.5    0.05      0.02          -0.06      -0.88   -0.55     0.55
  10       27       13.5    0.05      -0.03         -0.04      -0.34   -0.64     0.3
  11       27       13.5    0.05      -0.02         -0.06      -0.88   -0.55    -0.55
ASMTower 2018.4                     Job No.           40m Guyed Pole                         Rev. No.      A
                                    Client            OG                                     Date          5/11/2017
                                    Project           GSM Network                            Designed by   M.Joe
                                                                                             Checked by    A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx     OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m     KN.m      KN.m
          m             m
  12       27          13.5         0.05      0.03      -0.04   -0.34    -0.64     -0.3
  13       36              18       0.15      0.04      -0.17   -3.09    -2.34     1.5
  14       36              18       0.15      -0.07     -0.13   -1.83    -2.55     0.83
  15       36              18       0.15      -0.04     -0.17   -3.09    -2.34     -1.5
  16       36              18       0.15      0.07      -0.13   -1.83    -2.55    -0.83
  17       40              20       0.21      0.05      -0.23   -4.78    -3.81     2.1
  18       40              20       0.21      -0.09     -0.19   -3.14    -4.08     1.17
  19       40              20       0.21      -0.05     -0.23   -4.78    -3.81     -2.1
  20       40              20       0.21      0.09      -0.19   -3.14    -4.08    -1.17
       Total                        1.82          0     -1.83   -29.15   -28.85     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 180
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area     tiz      Ra       C        Cf     EPA      qz     Force
  No.      slice       Elev.         m        m          m2      mm                                 m2     N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75      0        0       7.3     0.72    0.537   444.3    0.2
               2           41        2        0.25       0.5      0      0.07     7.26     0.72    0.36    438.8   0.13
   2           1           38        4        0.25       1        0      0.07      7.2     0.73    0.727   431.8   0.27
   3           1       33.75         4.5      0.25      1.125     0      0.07     7.11     0.74    0.828   421.2    0.3
               2       29.25         4.5      0.25      1.125     0      0.07      7       0.75    0.84    408.7   0.29
   4           1       24.75         4.5      0.25      1.125     0      0.07     6.88     0.76    0.855   394.6   0.29
               2       20.25         4.5      0.25      1.125     0      0.07     6.74     0.78    0.874   378.3   0.28
   5           1       15.75         4.5      0.25      1.125     0      0.07     6.56      0.8    0.897   358.8   0.27
               2       11.25         4.5      0.25      1.125     0      0.07     6.33     0.83    0.929   334.2   0.26
   6           1       6.75          4.5      0.25      1.125     0      0.07      6       0.87    0.981   300.1   0.25
               2       2.25          4.5      0.25      1.125     0      0.07     5.76     0.91    1.021   276.8   0.24
                                              Total                                                8.849    ---    2.79
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt     EPAa     tiz       qz      θ      Force
                    m                m                   m2      m2       m2      mm       N/m2    Deg      KN
   1           40 To 42              41           1     0.804   0.228      0       0       438.8   180      0
   2           36 To 40              38           1     1.608   0.456      0       0       431.8   180      0
   3           31.5 To 36           33.75         1     1.809   0.513      0       0       421.2   180      0
   4           27 To 31.5           29.25         1     1.809   0.513      0       0       408.7   180      0
   5           22.5 To 27           24.75         1     1.809   0.513      0       0       394.6   180      0
ASMTower 2018.4                 Job No.          40m Guyed Pole                       Rev. No.      A
                                Client           OG                                   Date          5/11/2017
                                Project          GSM Network                          Designed by   M.Joe
                                                                                      Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz     qz      θ      Force
                m                   m               m2      m2       m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25     1        1.809   0.513     0        0     378.3   180      0
   7           13.5 To 18       15.75     1        1.809   0.513     0        0     358.8   180      0
   8           9 To 13.5        11.25     1        1.809   0.513     0        0     334.2   180      0
   9            4.5 To 9        6.75      1        1.809   0.513     0        0     300.1   180      0
  10            0 To 4.5        2.25      1        1.809   0.513     0        0     276.8   180      0
                                Total                                0        ---    ---     ---     0
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41      0            0     0         0        0        0
   2           38      0            0     0         0        0        0
   3       33.75       0            0     0         0        0        0
   4       29.25       0            0     0         0        0        0
   5       24.75       0            0     0         0        0        0
   6       20.25       0            0     0         0        0        0
   7       15.75       0            0     0         0        0        0
   8       11.25       0            0     0         0        0        0
   9       6.75        0            0     0         0        0        0
  10       2.25        0            0     0         0        0        0
       Total           0            0     0         0        0        0
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz     θ      Force
            m          m                  m2        m2      m2      mm       N/m2   Deg      KN
   1           42      42           1    1.815     0.62    1.516     0       441    150     0.57
   2           42      42           1    1.815     0.62    1.516     0       441     30     0.57
   3           42      42           1    1.815     0.62    0.62      0       441     90     0.23
                            Total                          3.652     ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42     0.57          0     0         0      -23.87    0.17
   2           42     0.57          0     0         0      -23.87    0.17
   3           42     0.23          0     0         0      -9.76    -0.14
       Total          1.37          0     0         0      -57.5     0.2
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                       Rev. No.        A
                              Client           OG                                   Date            5/11/2017
                              Project          GSM Network                          Designed by     M.Joe
                                                                                    Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
           m         m                  m2        m2      m2     mm       N/m2    Deg       KN
   1           42   42            1    0.034     0.358   0.115    0       441      150     0.04
   2           42   42            1    0.034     0.358   0.115    0       441      30      0.04
   3           42   42            1    0.034     0.358   0.358    0       441      90      0.13
                          Total                          0.587    ---      ---     ---     0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   0.04          0      0        0      -1.81    0.01
   2           42   0.04          0      0        0      -1.81    0.01
   3           42   0.13          0      0        0      -5.63   -0.05
       Total        0.22          0      0        0      -9.24   -0.04
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca      Cs       Cm      Fa      Fs    Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN    KN
   1           40   40        2400     4.524      0      436.5   150      -0.96   0.18     0.06     -1.61   0.3   0.25
   2           44   44        1200     1.131      0      445.4    30      1.21    0.23     -0.05    0.52    0.1   -0.03
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx    OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m    KN.m      KN.m
   1           40   1.54          0     0.55      0      0.25     0       21.91   -61.55    0.4
   2           44   0.5           0    -0.17      0      -0.03    0       -7.58   -21.96    0.03
       Total        2.04          0     0.38      ---     ---     ---     14.32   -83.51    0.43
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
            m        m                  m2        m2      m2     mm       N/m2    Deg       KN
   1           40   40            1      0       0.244   0.061    0       436.5    150     0.02
   2           44   44            1    0.034     0.244   0.087    0       445.4    30      0.03
                          Total                          0.148    ---      ---     ---     0.06
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40   0.02          0      0        0      -0.91     0
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44   0.03     0         0             0        -1.44    0.01
       Total        0.06     0         0             0        -2.35    0.01
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd            Lg          θg        qz       Fw
          Elev.     Elev.     mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     34.08      276.8     0.01
  2            9     4.5         8            1.2          17.493     102.82     276.8     0.04
  3            9     4.5         8            1.2          17.493     145.92     276.8     0.01
  4            9     4.5         8            1.2          17.493     77.18      276.8     0.04
  5        18         9          8            1.2          23.431      51.8      318.9     0.04
  6        18         9          8            1.2          23.431     99.54      318.9     0.06
  7        18         9          8            1.2          23.431     128.2      318.9     0.04
  8        18         9          8            1.2          23.431     80.46      318.9     0.06
  9        27        13.5        8            1.2          30.887     62.02      347.3     0.07
  10       27        13.5        8            1.2          30.887     97.22      347.3     0.09
  11       27        13.5        8            1.2          30.887     117.98     347.3     0.07
  12       27        13.5        8            1.2          30.887     82.78      347.3     0.09
  13       36         18         16           1.2           39        68.19      369       0.2
  14       36         18         16           1.2           39        95.71      369       0.23
  15       36         18         16           1.2           39        111.81     369       0.2
  16       36         18         16           1.2           39        84.29      369       0.23
  17       40         20         20           1.2          42.72      70.17      377.3     0.29
  18       40         20         20           1.2          42.72      95.21      377.3     0.33
  19       40         20         20           1.2          42.72      109.83     377.3     0.29
  20       40         20         20           1.2          42.72      84.79      377.3     0.33
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    0.01      0.01           0        -0.04    0.04     0.04
  2            9     4.5    0.04       0            0.01      0.06    -0.16     0.28
  3            9     4.5    0.01      -0.01          0        -0.04    0.04    -0.04
  4            9     4.5    0.04       0            0.01      0.06    -0.16    -0.28
  5        18        9      0.03      0.02           0        -0.09    -0.1     0.09
  6        18        9      0.06      -0.01         0.01      0.11    -0.51     0.44
  7        18        9      0.03      -0.02          0        -0.09    -0.1    -0.09
  8        18        9      0.06      0.01          0.01      0.11    -0.51    -0.44
  9        27       13.5    0.06      0.03           0        -0.12   -0.58     0.15
  10       27       13.5    0.09      -0.01         0.01      0.14    -1.14     0.63
  11       27       13.5    0.06      -0.03          0        -0.12   -0.58    -0.15
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.       A
                                    Client            OG                                    Date           5/11/2017
                                    Project           GSM Network                           Designed by    M.Joe
                                                                                            Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m      KN.m
          m             m
  12       27          13.5         0.09      0.01      0.01    0.14    -1.14    -0.63
  13       36              18       0.19      0.07      -0.01   -0.29   -2.84     0.42
  14       36              18       0.23      -0.02     0.01    0.31    -4.12     1.69
  15       36              18       0.19      -0.07     -0.01   -0.29   -2.84    -0.42
  16       36              18       0.23      0.02      0.01    0.31    -4.12    -1.69
  17       40              20       0.27      0.1       -0.01   -0.38   -4.76     0.6
  18       40              20       0.32      -0.03     0.01     0.4    -6.44     2.37
  19       40              20       0.27      -0.1      -0.01   -0.38   -4.76     -0.6
  20       40              20       0.32      0.03      0.01     0.4    -6.44    -2.37
       Total                        2.59          0     0.01    0.22    -41.24     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 225
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra       C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2     mm                                 m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0        0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5     0      0.84     7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1       0      0.84      7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125    0      0.84     7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125    0      0.84      7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125    0      0.84     6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125    0      0.84     6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125    0      0.84     6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125    0      0.84     6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125    0      0.84      6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125    0      0.84     5.76      1.2     1.35    276.8   0.32
                                              Total                                               13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa     tiz       qz       θ      Force
                    m                m                   m2      m2      m2      mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.443     0       438.8    135     0.17
   2           36 To 40              38           1     1.608   0.456   0.886     0       431.8    135     0.33
   3           31.5 To 36           33.75         1     1.809   0.513   0.996     0       421.2    135     0.36
   4           27 To 31.5           29.25         1     1.809   0.513   0.996     0       408.7    135     0.35
   5           22.5 To 27           24.75         1     1.809   0.513   0.996     0       394.6    135     0.33
ASMTower 2018.4                 Job No.          40m Guyed Pole                       Rev. No.      A
                                Client           OG                                   Date          5/11/2017
                                Project          GSM Network                          Designed by   M.Joe
                                                                                      Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt     EPAa     tiz     qz      θ      Force
                m                   m               m2      m2       m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513    0.996     0     378.3   135     0.32
   7           13.5 To 18       15.75      1       1.809   0.513    0.996     0     358.8   135      0.3
   8           9 To 13.5        11.25      1       1.809   0.513    0.996     0     334.2   135     0.28
   9            4.5 To 9        6.75       1       1.809   0.513    0.996     0     300.1   135     0.25
  10            0 To 4.5        2.25       1       1.809   0.513    0.996     0     276.8   135     0.23
                                Total                                9.3      ---    ---     ---    2.92
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           41     0.12          0     0.12     4.79    -4.79     -0.04
   2           38     0.23          0     0.23     8.74    -8.74     -0.07
   3       33.75      0.25          0     0.25     8.51    -8.51     -0.08
   4       29.25      0.24          0     0.24     7.16    -7.16     -0.07
   5       24.75      0.24          0     0.24     5.85    -5.85     -0.07
   6       20.25      0.23          0     0.23     4.59    -4.59     -0.07
   7       15.75      0.21          0     0.21     3.38    -3.38     -0.06
   8       11.25      0.2           0     0.2      2.25    -2.25     -0.06
   9       6.75       0.18          0     0.18     1.21    -1.21     -0.05
  10       2.25       0.17          0     0.17     0.37    -0.37     -0.05
       Total          2.07          0     2.07     46.85   -46.85    -0.62
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz       qz     θ      Force
            m          m                  m2        m2      m2      mm       N/m2   Deg      KN
   1           42      42           1    1.815     0.62    1.735      0      441    165     0.65
   2           42      42           1    1.815     0.62     0.7       0      441     75     0.26
   3           42      42           1    1.815     0.62    1.217      0      441     45     0.46
                            Total                          3.652     ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz     Torque
            m         KN            KN    KN       KN.m    KN.m      KN.m
   1           42     0.46          0     0.46     19.31   -19.31    -0.1
   2           42     0.19          0     0.19     7.79    -7.79     0.15
   3           42     0.32          0     0.32     13.55   -13.55    -0.19
       Total          0.97          0     0.97     40.66   -40.66    -0.14
Wind forces from mounts of panel antenna
ASMTower 2018.4              Job No.          40m Guyed Pole                       Rev. No.        A
                             Client           OG                                   Date            5/11/2017
                             Project          GSM Network                          Designed by     M.Joe
                                                                                   Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z           Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
           m         m                 m2        m2      m2     mm       N/m2    Deg       KN
   1           42   42           1    0.034     0.358   0.056    0       441      165     0.02
   2           42   42           1    0.034     0.358   0.336    0       441      75      0.13
   3           42   42           1    0.034     0.358   0.196    0       441      45      0.07
                         Total                          0.587    ---      ---     ---     0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz    Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m
   1           42   0.01         0     0.01     0.62    -0.62     0
   2           42   0.09         0     0.09     3.74    -3.74    0.05
   3           42   0.05         0     0.05     2.18    -2.18   -0.02
       Total        0.16         0     0.16     6.54    -6.54    0.02
Wind forces from MW dishes
   #       Elev.     Z       O.D.      Area     tiz      qz      θ        Ca      Cs       Cm      Fa      Fs      Mm
            m        m       mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40   40       2400     4.524      0      436.5   195      -0.98   -0.12    -0.03    -1.65   -0.21   -0.13
   2           44   44       1200     1.131      0      445.4    75      0.47    0.53     0.05     0.2     0.23    0.02
Wind vectors from MW dishes
   #       Elev.    Fx           Fy    Fz        Mx      My      Mz      OTMx    OTMz     Torque
            m       KN           KN    KN       KN.m    KN.m    KN.m     KN.m    KN.m      KN.m
   1           40   1.33         0     1.01      0      -0.13    0       40.2    -53.11    -0.24
   2           44   0.29         0     0.1       0      0.02     0       4.18    -12.7     0.14
       Total        1.62         0     1.1       ---     ---     ---     44.39   -65.81    -0.1
Wind forces from mounts Of MW dishes
   #       Elev.     Z           Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
            m        m                 m2        m2      m2     mm       N/m2    Deg       KN
   1           40   40           1      0       0.244   0.016    0       436.5    165     0.01
   2           44   44           1    0.034     0.244   0.23     0       445.4    75      0.09
                         Total                          0.246    ---      ---     ---     0.09
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx           Fy    Fz       OTMx    OTMz    Torque
            m       KN           KN    KN       KN.m    KN.m     KN.m
   1           40    0           0      0       0.17    -0.17     0
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44   0.06     0        0.06          2.71      -2.71    0.03
       Total        0.07     0        0.07          2.88      -2.88    0.03
Wind forces from guy wires
  #      Attach     Mean      Dia.            Cd            Lg          θg        qz       Fw
          Elev.     Elev.     mm                            m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     42.05      276.8     0.02
  2            9     4.5         8            1.2          17.493     64.61      276.8     0.03
  3            9     4.5         8            1.2          17.493     137.95     276.8     0.02
  4            9     4.5         8            1.2          17.493     115.39     276.8     0.03
  5        18         9          8            1.2          23.431     56.33      318.9     0.04
  6        18         9          8            1.2          23.431     71.33      318.9     0.05
  7        18         9          8            1.2          23.431     123.67     318.9     0.04
  8        18         9          8            1.2          23.431     108.67     318.9     0.05
  9        27        13.5        8            1.2          30.887     65.13      347.3     0.07
  10       27        13.5        8            1.2          30.887     75.95      347.3     0.08
  11       27        13.5        8            1.2          30.887     114.87     347.3     0.07
  12       27        13.5        8            1.2          30.887     104.05     347.3     0.08
  13       36         18         16           1.2           39        70.54      369       0.21
  14       36         18         16           1.2           39        78.91      369       0.23
  15       36         18         16           1.2           39        109.46     369       0.21
  16       36         18         16           1.2           39        101.09     369       0.23
  17       40         20         20           1.2          42.72       72.3      377.3     0.3
  18       40         20         20           1.2          42.72      79.89      377.3     0.32
  19       40         20         20           1.2          42.72      107.7      377.3     0.3
  20       40         20         20           1.2          42.72      100.11     377.3     0.32
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5     0        0.01          0.01      0.04     0.06     -0.1
  2            9     4.5    0.03      0.01          0.01         0    -0.14     0.23
  3            9     4.5     0        -0.01         0.01      0.04     0.06     0.1
  4            9     4.5    0.03      -0.01         0.01         0    -0.14    -0.23
  5        18        9      0.02      0.02          0.03      0.24    -0.01    -0.19
  6        18        9      0.04      0.01          0.03      0.16    -0.42     0.38
  7        18        9      0.02      -0.02         0.03      0.24    -0.01     0.19
  8        18        9      0.04      -0.01         0.03      0.16    -0.42    -0.38
  9        27       13.5    0.04      0.03          0.05      0.64    -0.34     -0.3
  10       27       13.5    0.06      0.02          0.05      0.55    -0.88     0.55
  11       27       13.5    0.04      -0.03         0.05      0.64    -0.34     0.3
ASMTower 2018.4                     Job No.           40m Guyed Pole                        Rev. No.       A
                                    Client            OG                                    Date           5/11/2017
                                    Project           GSM Network                           Designed by    M.Joe
                                                                                            Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz     Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m      KN.m
          m             m
  12       27          13.5         0.06      -0.02     0.05    0.55    -0.88    -0.55
  13       36              18       0.13      0.07      0.15    2.55    -1.83    -0.83
  14       36              18       0.17      0.04      0.15    2.34    -3.09     1.5
  15       36              18       0.13      -0.07     0.15    2.55    -1.83     0.83
  16       36              18       0.17      -0.04     0.15    2.34    -3.09     -1.5
  17       40              20       0.19      0.09      0.21    4.08    -3.14    -1.17
  18       40              20       0.23      0.05      0.21    3.81    -4.78     2.1
  19       40              20       0.19      -0.09     0.21    4.08    -3.14     1.17
  20       40              20       0.23      -0.05     0.21    3.81    -4.78     -2.1
       Total                        1.83          0     1.82    28.85   -29.15     0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 270
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra       C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2     mm                                 m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0        0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5     0       0.3     7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1       0       0.3      7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125    0       0.3     7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125    0       0.3      7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125    0       0.3     6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125    0       0.3     6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125    0       0.3     6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125    0       0.3     6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125    0       0.3      6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125    0       0.3     5.76      1.2     1.35    276.8   0.32
                                              Total                                               13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa     tiz       qz       θ      Force
                    m                m                   m2      m2      m2      mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.228     0       438.8    90      0.09
   2           36 To 40              38           1     1.608   0.456   0.456     0       431.8    90      0.17
   3           31.5 To 36           33.75         1     1.809   0.513   0.513     0       421.2    90      0.18
   4           27 To 31.5           29.25         1     1.809   0.513   0.513     0       408.7    90      0.18
   5           22.5 To 27           24.75         1     1.809   0.513   0.513     0       394.6    90      0.17
ASMTower 2018.4                 Job No.          40m Guyed Pole                      Rev. No.      A
                                Client           OG                                  Date          5/11/2017
                                Project          GSM Network                         Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt    EPAa     tiz     qz      θ      Force
                m                   m               m2      m2      m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513   0.513     0     378.3    90     0.16
   7           13.5 To 18       15.75      1       1.809   0.513   0.513     0     358.8    90     0.16
   8           9 To 13.5        11.25      1       1.809   0.513   0.513     0     334.2    90     0.15
   9            4.5 To 9        6.75       1       1.809   0.513   0.513     0     300.1    90     0.13
  10            0 To 4.5        2.25       1       1.809   0.513   0.513     0     276.8    90     0.12
                                Total                              4.788     ---    ---     ---    1.51
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           41      0            0     0.09     3.49     0       -0.03
   2           38      0            0     0.17     6.36     0       -0.05
   3       33.75       0            0     0.18      6.2     0       -0.06
   4       29.25       0            0     0.18     5.21     0       -0.05
   5       24.75       0            0     0.17     4.26     0       -0.05
   6       20.25       0            0     0.16     3.34     0       -0.05
   7       15.75       0            0     0.16     2.46     0       -0.05
   8       11.25       0            0     0.15     1.64     0       -0.04
   9       6.75        0            0     0.13     0.88     0       -0.04
  10       2.25        0            0     0.12     0.27     0       -0.04
       Total           0            0     1.51     34.12    0       -0.45
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz     θ      Force
            m          m                  m2        m2      m2     mm       N/m2   Deg      KN
   1           42      42           1    1.815     0.62    0.919     0      441    120     0.34
   2           42      42           1    1.815     0.62    0.919     0      441    120     0.34
   3           42      42           1    1.815     0.62    1.815     0      441     0      0.68
                            Total                          3.652    ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           42      0            0     0.34     14.47    0       -0.18
   2           42      0            0     0.34     14.47    0       0.18
   3           42      0            0     0.68     28.57    0        0
       Total           0            0     1.37     57.5     0        0
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                       Rev. No.        A
                              Client           OG                                   Date            5/11/2017
                              Project          GSM Network                          Designed by     M.Joe
                                                                                    Checked by      A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
           m         m                  m2        m2      m2     mm       N/m2    Deg       KN
   1           42    42           1    0.034     0.358   0.277    0       441      120      0.1
   2           42    42           1    0.034     0.358   0.277    0       441      120      0.1
   3           42    42           1    0.034     0.358   0.034    0       441       0      0.01
                          Total                          0.587    ---      ---     ---     0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42    0            0     0.1      4.35     0      -0.03
   2           42    0            0     0.1      4.35     0       0.03
   3           42    0            0     0.01     0.53     0        0
       Total         0            0     0.22     9.24     0        0
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca      Cs       Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                                KN      KN      KN
   1           40    40       2400     4.524      0      436.5   240      -0.71   -0.44    -0.1     -1.19   -0.73   -0.42
   2           44    44       1200     1.131      0      445.4   120      -0.71   0.44      0.1     -0.3    0.19    0.05
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx    OTMz     Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m    KN.m      KN.m
   1           40   0.67          0     1.23      0      -0.42    0       49.31   -26.65    -0.8
   2           44   -0.17         0     0.31      0      0.05     0       13.83   7.48      0.15
       Total        0.5           0     1.55      ---     ---     ---     63.14   -19.17    -0.65
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ       Force
            m        m                  m2        m2      m2     mm       N/m2    Deg       KN
   1           40    40           1      0       0.244   0.183    0       436.5    120     0.07
   2           44    44           1    0.034     0.244   0.192    0       445.4    120     0.07
                          Total                          0.375    ---      ---     ---     0.14
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40    0            0     0.07     2.72     0      -0.02
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44    0       0        0.07          3.19         0     0.02
       Total         0       0        0.14          5.91         0       0
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd            Lg          θg        qz       Fw
          Elev.     Elev.      mm                           m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     77.18      276.8     0.04
  2            9     4.5         8            1.2          17.493     34.08      276.8     0.01
  3            9     4.5         8            1.2          17.493     102.82     276.8     0.04
  4            9     4.5         8            1.2          17.493     145.92     276.8     0.01
  5        18         9          8            1.2          23.431     80.46      318.9     0.06
  6        18         9          8            1.2          23.431      51.8      318.9     0.04
  7        18         9          8            1.2          23.431     99.54      318.9     0.06
  8        18         9          8            1.2          23.431     128.2      318.9     0.04
  9        27        13.5        8            1.2          30.887     82.78      347.3     0.09
  10       27        13.5        8            1.2          30.887     62.02      347.3     0.07
  11       27        13.5        8            1.2          30.887     97.22      347.3     0.09
  12       27        13.5        8            1.2          30.887     117.98     347.3     0.07
  13       36         18         16           1.2           39        84.29      369       0.23
  14       36         18         16           1.2           39        68.19      369       0.2
  15       36         18         16           1.2           39        95.71      369       0.23
  16       36         18         16           1.2           39        111.81     369       0.2
  17       40         20         20           1.2          42.72      84.79      377.3     0.33
  18       40         20         20           1.2          42.72      70.17      377.3     0.29
  19       40         20         20           1.2          42.72      95.21      377.3     0.33
  20       40         20         20           1.2          42.72      109.83     377.3     0.29
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01      0            0.04      0.16     0.06    -0.28
  2            9     4.5     0        0.01          0.01      -0.04   -0.04     0.04
  3            9     4.5    -0.01      0            0.04      0.16     0.06     0.28
  4            9     4.5     0        -0.01         0.01      -0.04   -0.04    -0.04
  5        18        9      -0.01     0.01          0.06      0.51     0.11    -0.44
  6        18        9       0        0.02          0.03      0.1     -0.09     0.09
  7        18        9      -0.01     -0.01         0.06      0.51     0.11     0.44
  8        18        9       0        -0.02         0.03      0.1     -0.09    -0.09
  9        27       13.5    -0.01     0.01          0.09      1.14     0.14    -0.63
  10       27       13.5     0        0.03          0.06      0.58    -0.12     0.15
  11       27       13.5    -0.01     -0.01         0.09      1.14     0.14     0.63
ASMTower 2018.4                     Job No.           40m Guyed Pole                       Rev. No.       A
                                    Client            OG                                   Date           5/11/2017
                                    Project           GSM Network                          Designed by    M.Joe
                                                                                           Checked by     A.S.M
ASMTower 2018.4
  #    Attach          Mean          Fx       Fy         Fz     OTMx    OTMz    Torque
        Elev.          Elev.         KN       KN         KN     KN.m    KN.m     KN.m
          m             m
  12       27          13.5          0        -0.03     0.06    0.58    -0.12   -0.15
  13       36              18       -0.01     0.02      0.23    4.12    0.31    -1.69
  14       36              18       0.01      0.07      0.19    2.84    -0.29    0.42
  15       36              18       -0.01     -0.02     0.23    4.12    0.31     1.69
  16       36              18       0.01      -0.07     0.19    2.84    -0.29   -0.42
  17       40              20       -0.01     0.03      0.32    6.44     0.4    -2.37
  18       40              20       0.01      0.1       0.27    4.76    -0.38    0.6
  19       40              20       -0.01     -0.03     0.32    6.44     0.4     2.37
  20       40              20       0.01      -0.1      0.27    4.76    -0.38    -0.6
       Total                        -0.01         0     2.59    41.24   0.22      0
Wind Calculation Of Basic Service Wind Speed 25 m/s Dir. 315
Gust effect factor              Gh        =   0.85
Direction probability           Kd        =   0.85
Important factor                I         =   1
Wind forces on pole parts
  Part     Wind        Mean          L        Dav       Area    tiz      Ra      C        Cf     EPA       qz     Force
  No.      slice       Elev.         m        m          m2     mm                                m2      N/m2     KN
            No.         m
   1           1       43.5          3        0.25      0.75     0       0       7.3     0.72    0.537    444.3    0.2
               2           41        2        0.25       0.5     0      0.97    7.26      1.2     0.6     438.8   0.22
   2           1           38        4        0.25       1       0      0.97     7.2      1.2     1.2     431.8   0.44
   3           1       33.75         4.5      0.25      1.125    0      0.97    7.11      1.2     1.35    421.2   0.48
               2       29.25         4.5      0.25      1.125    0      0.97     7        1.2     1.35    408.7   0.47
   4           1       24.75         4.5      0.25      1.125    0      0.97    6.88      1.2     1.35    394.6   0.45
               2       20.25         4.5      0.25      1.125    0      0.97    6.74      1.2     1.35    378.3   0.43
   5           1       15.75         4.5      0.25      1.125    0      0.97    6.56      1.2     1.35    358.8   0.41
               2       11.25         4.5      0.25      1.125    0      0.97    6.33      1.2     1.35    334.2   0.38
   6           1       6.75          4.5      0.25      1.125    0      0.97     6        1.2     1.35    300.1   0.34
               2       2.25          4.5      0.25      1.125    0      0.97    5.76      1.2     1.35    276.8   0.32
                                              Total                                              13.137    ---    4.16
Wind forces from transmission line clusters
   #               Elev.             Z         Ka       EPAn    EPAt    EPAa    tiz       qz       θ      Force
                    m                m                   m2      m2      m2     mm       N/m2     Deg      KN
   1           40 To 42              41           1     0.804   0.228   0.516    0       438.8    45      0.19
   2           36 To 40              38           1     1.608   0.456   1.032    0       431.8    45      0.38
   3           31.5 To 36           33.75         1     1.809   0.513   1.161    0       421.2    45      0.42
   4           27 To 31.5           29.25         1     1.809   0.513   1.161    0       408.7    45       0.4
   5           22.5 To 27           24.75         1     1.809   0.513   1.161    0       394.6    45      0.39
ASMTower 2018.4                 Job No.          40m Guyed Pole                      Rev. No.      A
                                Client           OG                                  Date          5/11/2017
                                Project          GSM Network                         Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
   #         Elev.                  Z     Ka       EPAn    EPAt    EPAa     tiz     qz      θ      Force
                m                   m               m2      m2      m2      mm     N/m2    Deg      KN
   6           18 To 22.5       20.25      1       1.809   0.513   1.161     0     378.3    45     0.37
   7           13.5 To 18       15.75      1       1.809   0.513   1.161     0     358.8    45     0.35
   8           9 To 13.5        11.25      1       1.809   0.513   1.161     0     334.2    45     0.33
   9            4.5 To 9        6.75       1       1.809   0.513   1.161     0     300.1    45      0.3
  10            0 To 4.5        2.25       1       1.809   0.513   1.161     0     276.8    45     0.27
                                Total                              10.836    ---    ---     ---    3.41
Wind vector from transmission line clusters
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           41    -0.14          0     0.14     5.58    5.58     -0.04
   2           38    -0.27          0     0.27     10.18   10.18    -0.08
   3       33.75     -0.29          0     0.29     9.92    9.92     -0.09
   4       29.25     -0.29          0     0.29     8.34    8.34     -0.09
   5       24.75     -0.28          0     0.28     6.81    6.81     -0.08
   6       20.25     -0.26          0     0.26     5.34    5.34     -0.08
   7       15.75     -0.25          0     0.25     3.94    3.94     -0.08
   8       11.25     -0.23          0     0.23     2.62    2.62     -0.07
   9       6.75      -0.21          0     0.21     1.41    1.41     -0.06
  10       2.25      -0.19          0     0.19     0.43    0.43     -0.06
       Total         -2.41          0     2.41     54.59   54.59    -0.72
Wind forces from panel antenna
   #       Elev.       Z            Ka   EPAn      EPAt    EPAa     tiz      qz     θ      Force
            m          m                  m2        m2      m2      mm      N/m2   Deg      KN
   1           42      42           1    1.815     0.62     0.7      0      441     75     0.26
   2           42      42           1    1.815     0.62    1.735     0      441    165     0.65
   3           42      42           1    1.815     0.62    1.217     0      441     45     0.46
                            Total                          3.652    ---      ---    ---    1.37
Wind vector from panel antenna
   #       Elev.      Fx            Fy    Fz       OTMx    OTMz    Torque
            m         KN            KN    KN       KN.m    KN.m     KN.m
   1           42    -0.19          0     0.19     7.79    7.79     -0.15
   2           42    -0.46          0     0.46     19.31   19.31     0.1
   3           42    -0.32          0     0.32     13.55   13.55    0.19
       Total         -0.97          0     0.97     40.66   40.66    0.14
Wind forces from mounts of panel antenna
ASMTower 2018.4               Job No.          40m Guyed Pole                       Rev. No.       A
                              Client           OG                                   Date           5/11/2017
                              Project          GSM Network                          Designed by    M.Joe
                                                                                    Checked by     A.S.M
ASMTower 2018.4
   #     Elev.       Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ      Force
           m         m                  m2        m2      m2     mm       N/m2    Deg      KN
   1           42    42           1    0.034     0.358   0.336    0       441      75     0.13
   2           42    42           1    0.034     0.358   0.056    0       441     165     0.02
   3           42    42           1    0.034     0.358   0.196    0       441      45     0.07
                          Total                          0.587    ---      ---     ---    0.22
Wind vector from mounts of panel antenna
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           42   -0.09         0     0.09     3.74    3.74    -0.05
   2           42   -0.01         0     0.01     0.62    0.62      0
   3           42   -0.05         0     0.05     2.18    2.18     0.02
       Total        -0.16         0     0.16     6.54    6.54    -0.02
Wind forces from MW dishes
   #       Elev.     Z        O.D.      Area     tiz      qz      θ        Ca      Cs      Cm      Fa      Fs      Mm
            m        m        mm         m2      mm      N/m2    Deg                               KN      KN      KN
   1           40    40       2400     4.524      0      436.5   285      0.47    -0.53   -0.05    0.79    -0.89   -0.19
   2           44    44       1200     1.131      0      445.4   165      -0.98   0.12    0.03     -0.42   0.05    0.02
Wind vectors from MW dishes
   #       Elev.    Fx            Fy    Fz        Mx      My      Mz      OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m    KN.m     KN.m    KN.m     KN.m
   1           40   -1.13         0     0.37      0      -0.19    0       14.91   45.25    -0.65
   2           44   -0.34         0     0.26      0      0.02     0       11.28   14.9     0.04
       Total        -1.47         0     0.63      ---     ---     ---     26.19   60.16    -0.61
Wind forces from mounts Of MW dishes
   #       Elev.     Z            Ka   EPAn      EPAt    EPAa    tiz       qz      θ      Force
            m        m                  m2        m2      m2     mm       N/m2    Deg      KN
   1           40    40           1      0       0.244   0.228    0       436.5    75     0.08
   2           44    44           1    0.034     0.244   0.048    0       445.4   165     0.02
                          Total                          0.276    ---      ---     ---     0.1
Wind vectors from mounts Of MW dishes
   #       Elev.    Fx            Fy    Fz       OTMx    OTMz    Torque
            m       KN            KN    KN       KN.m    KN.m     KN.m
   1           40   -0.06         0     0.06     2.39    2.39    -0.03
ASMTower 2018.4             Job No.           40m Guyed Pole                             Rev. No.      A
                            Client            OG                                         Date          5/11/2017
                            Project           GSM Network                                Designed by   M.Joe
                                                                                         Checked by    A.S.M
ASMTower 2018.4
   #     Elev.       Fx     Fy        Fz           OTMx      OTMz     Torque
           m         KN     KN        KN           KN.m      KN.m      KN.m
   2           44   -0.01    0        0.01          0.57      0.57       0
       Total        -0.07    0        0.07          2.96      2.96     -0.03
Wind forces from guy wires
  #      Attach     Mean       Dia.           Cd            Lg          θg        qz       Fw
          Elev.     Elev.      mm                           m          Deg       N/m2      KN
           m         m
  1            9     4.5         8            1.2          17.493     115.39     276.8     0.03
  2            9     4.5         8            1.2          17.493     42.05      276.8     0.02
  3            9     4.5         8            1.2          17.493     64.61      276.8     0.03
  4            9     4.5         8            1.2          17.493     137.95     276.8     0.02
  5        18         9          8            1.2          23.431     108.67     318.9     0.05
  6        18         9          8            1.2          23.431     56.33      318.9     0.04
  7        18         9          8            1.2          23.431     71.33      318.9     0.05
  8        18         9          8            1.2          23.431     123.67     318.9     0.04
  9        27        13.5        8            1.2          30.887     104.05     347.3     0.08
  10       27        13.5        8            1.2          30.887     65.13      347.3     0.07
  11       27        13.5        8            1.2          30.887     75.95      347.3     0.08
  12       27        13.5        8            1.2          30.887     114.87     347.3     0.07
  13       36         18         16           1.2           39        101.09     369       0.23
  14       36         18         16           1.2           39        70.54      369       0.21
  15       36         18         16           1.2           39        78.91      369       0.23
  16       36         18         16           1.2           39        109.46     369       0.21
  17       40         20         20           1.2          42.72      100.11     377.3     0.32
  18       40         20         20           1.2          42.72       72.3      377.3     0.3
  19       40         20         20           1.2          42.72      79.89      377.3     0.32
  20       40         20         20           1.2          42.72      107.7      377.3     0.3
Wind vector from guy wires
  #      Attach     Mean    Fx        Fy            Fz       OTMx     OTMz     Torque
          Elev.     Elev.   KN        KN            KN       KN.m     KN.m      KN.m
           m         m
  1            9     4.5    -0.01     -0.01         0.03      0.14      0      -0.23
  2            9     4.5    -0.01     0.01           0        -0.06    0.04     -0.1
  3            9     4.5    -0.01     0.01          0.03      0.14      0       0.23
  4            9     4.5    -0.01     -0.01          0        -0.06    0.04     0.1
  5        18        9      -0.03     -0.01         0.04      0.42     0.16    -0.38
  6        18        9      -0.03     0.02          0.02      0.01     0.24    -0.19
  7        18        9      -0.03     0.01          0.04      0.42     0.16     0.38
  8        18        9      -0.03     -0.02         0.02      0.01     0.24     0.19
  9        27       13.5    -0.05     -0.02         0.06      0.88     0.55    -0.55
  10       27       13.5    -0.05     0.03          0.04      0.34     0.64     -0.3
  11       27       13.5    -0.05     0.02          0.06      0.88     0.55     0.55
ASMTower 2018.4               Job No.           40m Guyed Pole                         Rev. No.       A
                              Client            OG                                     Date           5/11/2017
                              Project           GSM Network                            Designed by    M.Joe
                                                                                       Checked by     A.S.M
ASMTower 2018.4
  #    Attach       Mean      Fx         Fy        Fz    OTMx      OTMz     Torque
        Elev.       Elev.     KN         KN        KN    KN.m      KN.m      KN.m
          m          m
    12       27     13.5      -0.05     -0.03     0.04   0.34       0.64     0.3
    13       36      18       -0.15     -0.04     0.17   3.09       2.34     -1.5
    14       36      18       -0.15     0.07      0.13   1.83       2.55    -0.83
    15       36      18       -0.15     0.04      0.17   3.09       2.34     1.5
    16       36      18       -0.15     -0.07     0.13   1.83       2.55     0.83
    17       40      20       -0.21     -0.05     0.23   4.78       3.81     -2.1
    18       40      20       -0.21     0.09      0.19   3.14       4.08    -1.17
    19       40      20       -0.21     0.05      0.23   4.78       3.81     2.1
    20       40      20       -0.21     -0.09     0.19   3.14       4.08     1.17
         Total                -1.82      0        1.83   29.15     28.85      0
Combination
Comb.        Description
No.
1            1.2D.L.+1Dg+1.6DesignWL_0Deg_36.11m/s
2            1.2D.L.+1Dg+1.6DesignWL_45Deg_36.11m/s
3            1.2D.L.+1Dg+1.6DesignWL_90Deg_36.11m/s
4            1.2D.L.+1Dg+1.6DesignWL_135Deg_36.11m/s
5            1.2D.L.+1Dg+1.6DesignWL_180Deg_36.11m/s
6            1.2D.L.+1Dg+1.6DesignWL_225Deg_36.11m/s
7            1.2D.L.+1Dg+1.6DesignWL_270Deg_36.11m/s
8            1.2D.L.+1Dg+1.6DesignWL_315Deg_36.11m/s
9            1D.L.+1Dg+1ServiceWL_0Deg_25m/s
10           1D.L.+1Dg+1ServiceWL_45Deg_25m/s
11           1D.L.+1Dg+1ServiceWL_90Deg_25m/s
12           1D.L.+1Dg+1ServiceWL_135Deg_25m/s
13           1D.L.+1Dg+1ServiceWL_180Deg_25m/s
14           1D.L.+1Dg+1ServiceWL_225Deg_25m/s
15           1D.L.+1Dg+1ServiceWL_270Deg_25m/s
16           1D.L.+1Dg+1ServiceWL_315Deg_25m/s
Pole Section Properties
 Sec.      Elev.   Diameter     Thick.           Area             Inertia             Elastic         Plastic
 No.        m        mm          mm              mm2               mm4               Modulus         Modulus
                                                                                       mm3             mm3
    1       45       250           10           7539.8           54380969            435048          576333
    2       44       250           10           7539.8           54380969            435048          576333
    3       44       250           10           7539.8           54380969            435048          576333
    4       43       250           10           7539.8           54380969            435048          576333
    5       43       250           10           7539.8           54380969            435048          576333
    6       42       250           10           7539.8           54380969            435048          576333
    7       42       250           10           7539.8           54380969            435048          576333
ASMTower 2018.4            Job No.   40m Guyed Pole               Rev. No.       A
                           Client    OG                           Date           5/11/2017
                           Project   GSM Network                  Designed by    M.Joe
                                                                  Checked by     A.S.M
ASMTower 2018.4
 Sec. Elev.     Diameter    Thick.    Area            Inertia    Elastic         Plastic
 No.     m        mm         mm       mm2              mm4      Modulus         Modulus
                                                                  mm3             mm3
  8     41        250         10     7539.8       54380969      435048          576333
  9     41        250         10     7539.8       54380969      435048          576333
 10     40        250         10     7539.8       54380969      435048          576333
 11     40        250         10     7539.8       54380969      435048          576333
 12     39.2      250         10     7539.8       54380969      435048          576333
 13     39.2      250         10     7539.8       54380969      435048          576333
 14     38.4      250         10     7539.8       54380969      435048          576333
 15     38.4      250         10     7539.8       54380969      435048          576333
 16     37.6      250         10     7539.8       54380969      435048          576333
 17     37.6      250         10     7539.8       54380969      435048          576333
 18     36.8      250         10     7539.8       54380969      435048          576333
 19     36.8      250         10     7539.8       54380969      435048          576333
 20     36        250         10     7539.8       54380969      435048          576333
 21     36        250         10     7539.8       54380969      435048          576333
 22     34.2      250         10     7539.8       54380969      435048          576333
 23     34.2      250         10     7539.8       54380969      435048          576333
 24     32.4      250         10     7539.8       54380969      435048          576333
 25     32.4      250         10     7539.8       54380969      435048          576333
 26     30.6      250         10     7539.8       54380969      435048          576333
 27     30.6      250         10     7539.8       54380969      435048          576333
 28     28.8      250         10     7539.8       54380969      435048          576333
 29     28.8      250         10     7539.8       54380969      435048          576333
 30     27        250         10     7539.8       54380969      435048          576333
 31     27        250         10     7539.8       54380969      435048          576333
 32     25.2      250         10     7539.8       54380969      435048          576333
 33     25.2      250         10     7539.8       54380969      435048          576333
 34     23.4      250         10     7539.8       54380969      435048          576333
 35     23.4      250         10     7539.8       54380969      435048          576333
 36     21.6      250         10     7539.8       54380969      435048          576333
 37     21.6      250         10     7539.8       54380969      435048          576333
 38     19.8      250         10     7539.8       54380969      435048          576333
 39     19.8      250         10     7539.8       54380969      435048          576333
 40     18        250         10     7539.8       54380969      435048          576333
 41     18        250         10     7539.8       54380969      435048          576333
 42     16.2      250         10     7539.8       54380969      435048          576333
 43     16.2      250         10     7539.8       54380969      435048          576333
 44     14.4      250         10     7539.8       54380969      435048          576333
 45     14.4      250         10     7539.8       54380969      435048          576333
 46     12.6      250         10     7539.8       54380969      435048          576333
 47     12.6      250         10     7539.8       54380969      435048          576333
 48     10.8      250         10     7539.8       54380969      435048          576333
 49     10.8      250         10     7539.8       54380969      435048          576333
 50      9        250         10     7539.8       54380969      435048          576333
ASMTower 2018.4            Job No.        40m Guyed Pole                           Rev. No.       A
                           Client         OG                                       Date           5/11/2017
                           Project        GSM Network                              Designed by    M.Joe
                                                                                   Checked by     A.S.M
ASMTower 2018.4
 Sec. Elev.     Diameter       Thick.         Area            Inertia             Elastic         Plastic
 No.     m        mm            mm            mm2              mm4               Modulus         Modulus
                                                                                   mm3             mm3
 51      9         250          10        7539.8            54380969             435048          576333
 52      7.2       250          10        7539.8            54380969             435048          576333
 53      7.2       250          10        7539.8            54380969             435048          576333
 54      5.4       250          10        7539.8            54380969             435048          576333
 55      5.4       250          10        7539.8            54380969             435048          576333
 56      3.6       250          10        7539.8            54380969             435048          576333
 57      3.6       250          10        7539.8            54380969             435048          576333
 58      1.8       250          10        7539.8            54380969             435048          576333
 59      1.8       250          10        7539.8            54380969             435048          576333
 60      0         250          10        7539.8            54380969             435048          576333
Pole capacity details
 Sec.   Elev.    W/t     Fy'            φPn          φMn                 φVn           φTn        Comment
 No.     m      or D/t   MPa            KN           KN.m               KN.m          KN.m
  1      45      25      248         1682.89         128.64             841.44       194.21
  2      44      25      248         1682.89         128.64             841.44       194.21
  3      44      25      248         1682.89         128.64             841.44       194.21
  4      43      25      248         1682.89         128.64             841.44       194.21
  5      43      25      248         1682.89         128.64             841.44       194.21
  6      42      25      248         1682.89         128.64             841.44       194.21
  7      42      25      248         1682.89         128.64             841.44       194.21
  8      41      25      248         1682.89         128.64             841.44       194.21
  9      41      25      248         1682.89         128.64             841.44       194.21
 10      40      25      248         1682.89         128.64             841.44       194.21
 11      40      25      248         1682.89         128.64             841.44       194.21
 12     39.2     25      248         1682.89         128.64             841.44       194.21
 13     39.2     25      248         1682.89         128.64             841.44       194.21
 14     38.4     25      248         1682.89         128.64             841.44       194.21
 15     38.4     25      248         1682.89         128.64             841.44       194.21
 16     37.6     25      248         1682.89         128.64             841.44       194.21
 17     37.6     25      248         1682.89         128.64             841.44       194.21
 18     36.8     25      248         1682.89         128.64             841.44       194.21
 19     36.8     25      248         1682.89         128.64             841.44       194.21
 20      36      25      248         1682.89         128.64             841.44       194.21
 21      36      25      248         1682.89         128.64             841.44       194.21
 22     34.2     25      248         1682.89         128.64             841.44       194.21
 23     34.2     25      248         1682.89         128.64             841.44       194.21
 24     32.4     25      248         1682.89         128.64             841.44       194.21
 25     32.4     25      248         1682.89         128.64             841.44       194.21
 26     30.6     25      248         1682.89         128.64             841.44       194.21
 27     30.6     25      248         1682.89         128.64             841.44       194.21
 28     28.8     25      248         1682.89         128.64             841.44       194.21
ASMTower 2018.4           Job No.         40m Guyed Pole                          Rev. No.         A
                          Client          OG                                      Date             5/11/2017
                          Project         GSM Network                             Designed by      M.Joe
                                                                                  Checked by       A.S.M
ASMTower 2018.4
 Sec. Elev.      W/t     Fy'         φPn              φMn              φVn              φTn        Comment
 No.     m      or D/t   MPa         KN               KN.m            KN.m             KN.m
  29    28.8      25     248        1682.89           128.64          841.44           194.21
  30     27       25     248        1682.89           128.64          841.44           194.21
  31     27       25     248        1682.89           128.64          841.44           194.21
  32    25.2      25     248        1682.89           128.64          841.44           194.21
  33    25.2      25     248        1682.89           128.64          841.44           194.21
  34    23.4      25     248        1682.89           128.64          841.44           194.21
  35    23.4      25     248        1682.89           128.64          841.44           194.21
  36    21.6      25     248        1682.89           128.64          841.44           194.21
  37    21.6      25     248        1682.89           128.64          841.44           194.21
  38    19.8      25     248        1682.89           128.64          841.44           194.21
  39    19.8      25     248        1682.89           128.64          841.44           194.21
  40     18       25     248        1682.89           128.64          841.44           194.21
  41     18       25     248        1682.89           128.64          841.44           194.21
  42    16.2      25     248        1682.89           128.64          841.44           194.21
  43    16.2      25     248        1682.89           128.64          841.44           194.21
  44    14.4      25     248        1682.89           128.64          841.44           194.21
  45    14.4      25     248        1682.89           128.64          841.44           194.21
  46    12.6      25     248        1682.89           128.64          841.44           194.21
  47    12.6      25     248        1682.89           128.64          841.44           194.21
  48    10.8      25     248        1682.89           128.64          841.44           194.21
  49    10.8      25     248        1682.89           128.64          841.44           194.21
  50      9       25     248        1682.89           128.64          841.44           194.21
  51      9       25     248        1682.89           128.64          841.44           194.21
  52     7.2      25     248        1682.89           128.64          841.44           194.21
  53     7.2      25     248        1682.89           128.64          841.44           194.21
  54     5.4      25     248        1682.89           128.64          841.44           194.21
  55     5.4      25     248        1682.89           128.64          841.44           194.21
  56     3.6      25     248        1682.89           128.64          841.44           194.21
  57     3.6      25     248        1682.89           128.64          841.44           194.21
  58     1.8      25     248        1682.89           128.64          841.44           194.21
  59     1.8      25     248        1682.89           128.64          841.44           194.21
  60      0       25     248        1682.89           128.64          841.44           194.21
Pole Sections Check
 Sec.    Elev.    Pu       Mu        Vu        Tu       Comb   Pu /     Mu /    Vu /      Tu /   Comb.    Check
 No.      m       KN      KN.m       KN       KN.m        .    φPn      φMn     φVn       φTn    Stress
                                                         No.                                     Ratio
   1      45       0       0          0        0          2     0         0      0         0       0      Safe
   2      44      1.42    0.81       1.07     -0.08       8     0        0.01    0         0      0.01    Safe
   3      44      1.42    0.81       1.07     -0.08       8     0        0.01    0         0      0.01    Safe
   4      43      2.85    2.57       1.85     -0.16       8     0        0.02    0         0      0.02    Safe
   5      43      2.85    2.57       1.85     -0.16       8     0        0.02    0         0      0.02    Safe
   6      42      5.28    7.24       4.69     -0.35       8     0        0.06   0.01       0      0.06    Safe
ASMTower 2018.4            Job No.         40m Guyed Pole                     Rev. No.       A
                           Client          OG                                 Date           5/11/2017
                           Project         GSM Network                        Designed by    M.Joe
                                                                              Checked by     A.S.M
ASMTower 2018.4
 Sec.   Elev.      Pu       Mu       Vu        Tu      Comb   Pu /   Mu /   Vu /   Tu /   Comb.    Check
  No.     m        KN      KN.m      KN       KN.m       .    φPn    φMn    φVn    φTn    Stress
                                                        No.                               Ratio
   7      42       5.28    7.24      4.69      -0.35    8      0     0.06   0.01    0       0.06   Safe
   8      41       6.06    12.35     5.38      -0.28    8      0     0.1    0.01    0       0.1    Safe
   9      41       6.06    12.35     5.38      -0.28    8      0     0.1    0.01    0       0.1    Safe
  10      40      10.07    22.35     11.2      -1.33    4     0.01   0.17   0.01   0.01     0.18   Safe
  11      40      114.17   22.02     4.8       0.81     1     0.07   0.17   0.01    0       0.24   Safe
  12     39.2     111.61   22.7      0.93      -2.01    5     0.07   0.18    0     0.01     0.24   Safe
  13     39.2     111.61   22.7      0.93      -2.01    5     0.07   0.18    0     0.01     0.24   Safe
  14     38.4     112.24   23.99     0.8       -2.01    5     0.07   0.19    0     0.01     0.25   Safe
  15     38.4     112.24   23.99     0.8       -2.01    5     0.07   0.19    0     0.01     0.25   Safe
  16     37.6     112.86   25.25     0.68      -2.01    5     0.07   0.2     0     0.01     0.26   Safe
  17     37.6     112.86   25.25     0.68      -2.01    5     0.07   0.2     0     0.01     0.26   Safe
  18     36.8     113.49   26.48     0.58      -2.01    5     0.07   0.21    0     0.01     0.27   Safe
  19     36.8     113.49   26.48     0.58      -2.01    5     0.07   0.21    0     0.01     0.27   Safe
  20      36      114.11   27.67     0.49      -2.01    5     0.07   0.22    0     0.01     0.28   Safe
  21      36      181.55   27.22     7.18      0.81     1     0.11   0.21   0.01    0       0.32   Safe
  22     34.2     172.02   24.41     3.77      -2.01    5     0.1    0.19    0     0.01     0.29   Safe
  23     34.2     172.02   24.41     3.77      -2.01    5     0.1    0.19    0     0.01     0.29   Safe
  24     32.4     173.43   20.52     3.45      -2.01    5     0.1    0.16    0     0.01     0.26   Safe
  25     32.4     173.43   20.52     3.45      -2.01    5     0.1    0.16    0     0.01     0.26   Safe
  26     30.6     174.83   16.17     3.13      -2.01    5     0.1    0.13    0     0.01     0.23   Safe
  27     30.6     174.83   16.17     3.13      -2.01    5     0.1    0.13    0     0.01     0.23   Safe
  28     28.8     176.24   11.56     2.82      -2.01    5     0.1    0.09    0     0.01     0.19   Safe
  29     28.8     176.24   11.56     2.82      -2.01    5     0.1    0.09    0     0.01     0.19   Safe
  30      27      177.64   6.92      2.51      -2.01    5     0.11   0.05    0     0.01     0.16   Safe
  31      27      192.22   6.92      1.52      -2.01    5     0.11   0.05    0     0.01     0.17   Safe
  32     25.2     207.38   6.43      2.13      0.81     1     0.12   0.05    0      0       0.17   Safe
  33     25.2     207.38   6.43      2.13      0.81     1     0.12   0.05    0      0       0.17   Safe
  34     23.4     208.79   8.45      0.72      0.81     1     0.12   0.07    0      0       0.19   Safe
  35     23.4     208.79   8.45      0.72      0.81     1     0.12   0.07    0      0       0.19   Safe
  36     21.6     210.19   7.44      0.69      0.81     1     0.12   0.06    0      0       0.18   Safe
  37     21.6     210.19   7.44      0.69      0.81     1     0.12   0.06    0      0       0.18   Safe
  38     19.8     211.6    3.51      2.04      0.81     1     0.13   0.03    0      0       0.15   Safe
  39     19.8     211.6    3.51      2.04      0.81     1     0.13   0.03    0      0       0.15   Safe
  40      18       213     3.07      3.39      0.81     1     0.13   0.02    0      0       0.15   Safe
  41      18      228.42   3.07      3.42      0.81     1     0.14   0.02    0      0       0.16   Safe
  42     16.2     212.25   3.13      0.02      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  43     16.2     212.25   3.13      0.02      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  44     14.4     213.65   3.07      0.29      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  45     14.4     213.65   3.07      0.29      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  46     12.6     215.06   2.32      0.55      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  47     12.6     215.06   2.32      0.55      -2.01    5     0.13   0.02    0     0.01     0.15   Safe
  48     10.8     234.04   3.91      1.59      0.81     1     0.14   0.03    0      0       0.17   Safe
  49     10.8     234.04   3.91      1.59      0.81     1     0.14   0.03    0      0       0.17   Safe
ASMTower 2018.4             Job No.           40m Guyed Pole                     Rev. No.       A
                            Client            OG                                 Date           5/11/2017
                            Project           GSM Network                        Designed by    M.Joe
                                                                                 Checked by     A.S.M
ASMTower 2018.4
 Sec.   Elev.      Pu        Mu       Vu          Tu     Comb    Pu /   Mu /   Vu /   Tu /   Comb.     Check
  No.     m        KN       KN.m      KN         KN.m      .     φPn    φMn    φVn    φTn    Stress
                                                          No.                                Ratio
  50       9      235.44     9.39     2.79        0.81       1   0.14   0.07    0      0       0.21    Safe
  51       9      243.84     9.39     4.19        0.81       1   0.14   0.07    0      0       0.22    Safe
  52      7.2     245.24     3.88     3.11        0.81       1   0.15   0.03    0      0       0.18    Safe
  53      7.2     245.24     3.88     3.11        0.81       1   0.15   0.03    0      0       0.18    Safe
  54      5.4     246.65     0.05     2.03        0.81       1   0.15    0      0      0       0.15    Safe
  55      5.4     246.65     0.05     2.03        0.81       1   0.15    0      0      0       0.15    Safe
  56      3.6     248.06     1.91         1       0.81       1   0.15   0.01    0      0       0.16    Safe
  57      3.6     248.06     1.91         1       0.81       1   0.15   0.01    0      0       0.16    Safe
  58      1.8     249.46     1.92     0.01        0.81       1   0.15   0.01    0      0       0.16    Safe
  59      1.8     249.46     1.92     0.01        0.81       1   0.15   0.01    0      0       0.16    Safe
  60       0      250.87      0       0.99        0.81       1   0.15    0      0      0       0.15    Safe
Guy Wire Input Data
 Wire Elev. of    Elev.    Radius Offset Leg Or Horizo Lateral Azimut Inital Efficie           Comme
 No. Attach.       of      of Base Type** Face   ntal  Offset     h   Tensio  ncy                nt
         m        Base        m            ID   Offset   m     Adjust   n      %
                   m                              m              m      %
  1        9        0        15       1          A       0       0      -15     10      90
  2        9        0        15       1          B       0       0      -45     10      90
  3        9        0        15       1          C       0       0      -75     10      90
  4        9        0        15       1          C       0       0      15      10      90
  5       18        0        15       1          A       0       0      -15     10      90
  6       18        0        15       1          B       0       0      -45     10      90
  7       18        0        15       1          C       0       0      -75     10      90
  8       18        0        15       1          C       0       0      15      10      90
  9       27        0        15       1          A       0       0      -15     10      90
  10      27        0        15       1          B       0       0      -45     10      90
  11      27        0        15       1          C       0       0      -75     10      90
  12      27        0        15       1          C       0       0      15      10      90
  13      36        0        15       1          A       0       0      -15     10      90
  14      36        0        15       1          B       0       0      -45     10      90
  15      36        0        15       1          C       0       0      -75     10      90
  16      36        0        15       1          C       0       0      15      10      90
  17      40        0        15       1          A       0       0      -15     10      90
  18      40        0        15       1          B       0       0      -45     10      90
  19      40        0        15       1          C       0       0      -75     10      90
  20      40        0        15       1          C       0       0      15      10      90
**Offset Type :
1 SINGLE LEG
Guy Wire Check
ASMTower 2018.4               Job No.       40m Guyed Pole                                 Rev. No.          A
                              Client        OG                                             Date              5/11/2017
                              Project       GSM Network                                    Designed by       M.Joe
                                                                                           Checked by        A.S.M
ASMTower 2018.4
 Wire Diam.        Force      Breaking           Tg             φg            φg Tg      Ratio      Check
 No.    mm          KN        Strength           KN                            KN
                                 KN
  1      8        8.26 (1)       37.6           33.84           0.6           20.3       0.41        Safe
  2      8        6.47 (4)       37.6           33.84           0.6           20.3       0.32        Safe
  3      8         6.5 (6)       37.6           33.84           0.6           20.3       0.32        Safe
  4      8        6.71 (8)       37.6           33.84           0.6           20.3       0.33        Safe
  5      8        11.22 (1)      37.6           33.84           0.6           20.3       0.55        Safe
  6      8        8.13 (4)       37.6           33.84           0.6           20.3        0.4        Safe
  7      8        7.81 (6)       37.6           33.84           0.6           20.3       0.38        Safe
  8      8        8.67 (8)       37.6           33.84           0.6           20.3       0.43        Safe
  9      8        9.81 (1)       37.6           33.84           0.6           20.3       0.48        Safe
  10     8        7.19 (4)       37.6           33.84           0.6           20.3       0.35        Safe
  11     8        6.82 (6)       37.6           33.84           0.6           20.3       0.34        Safe
  12     8        7.62 (8)       37.6           33.84           0.6           20.3       0.38        Safe
  13     16       32.43 (1)      150            135             0.6            81         0.4        Safe
  14     16       25.29 (4)      150            135             0.6            81        0.31        Safe
  15     16       26.49 (6)      150            135             0.6            81        0.33        Safe
  16     16       25.49 (8)      150            135             0.6            81        0.31        Safe
  17     20       57.58 (1)      235            211.5           0.6           126.9      0.45        Safe
  18     20       49.37 (3)      235            211.5           0.6           126.9      0.39        Safe
  19     20       51.48 (5)      235            211.5           0.6           126.9      0.41        Safe
  20     20       49.42 (7)      235            211.5           0.6           126.9      0.39        Safe
Guy Wire Force
Wire Comb.        Fx at       Fy at      Fz at          Ft at      Fx at        Fy at     Fz at     Ft at
No.   No.         Base        Base       Base           Base      Attach.      Attach.   Attach.   Attach.
                   KN          KN         KN             KN         KN           KN        KN        KN
  1      1         6.85       -4.2       1.82           8.24          -6.83      4.28     -1.84     8.26
  1      2         5.55       -3.4       1.51           6.68          -5.54      3.48     -1.46     6.71
  1      3         3.65       -2.25      1.04           4.41          -3.67      2.3      -0.92     4.43
  1      4         1.84       -1.14      0.55           2.23          -1.88      1.16     -0.45     2.25
  1      5         2.01       -1.25      0.55           2.43          -2.03      1.26     -0.53     2.45
  1      6         0.85       -0.52       0.2           1.02          -0.85      0.53     -0.25     1.04
  1      7         2.64       -1.62      0.64           3.16          -2.61      1.65     -0.76     3.18
  1      8         4.56       -2.78      1.16           5.47          -4.52      2.85     -1.26     5.49
  1      9         3.93       -2.41      1.05           4.73          -3.92      2.46     -1.05     4.75
  1      10        3.67       -2.25      0.99           4.42          -3.67      2.31     -0.98     4.44
  1      11        3.14       -1.93      0.86           3.79          -3.15      1.98     -0.83     3.81
  1      12         2.6       -1.6       0.71           3.14          -2.61      1.64     -0.68     3.16
  1      13        2.63       -1.62      0.71           3.17          -2.63      1.65     -0.7      3.19
  1      14        2.32       -1.43      0.62            2.8          -2.33      1.46     -0.63     2.82
  1      15        2.84       -1.74      0.74           3.42          -2.83      1.78     -0.78     3.44
  1      16        3.39       -2.08      0.89           4.08          -3.38      2.13     -0.92      4.1
  2      1         -0.55      -1.41      2.31           2.76          0.67       1.44     -2.29     2.79
  2      2         -1.15      -2.76      4.52           5.42          1.25       2.83     -4.48     5.45
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  2      3      -1.33   -3.06     5.01     6.02       1.34     3.14      -4.98     6.04
  2      4      -1.46   -3.28     5.36     6.45       1.41     3.36      -5.35     6.47
  2      5      -0.97   -2.08     3.38     4.09       0.85     2.14      -3.41     4.11
  2      6      -0.56   -1.17     1.87     2.28       0.46     1.19      -1.92      2.3
  2      7      -0.26   -0.58     0.93     1.12       0.25     0.59      -0.95     1.15
  2      8      -0.18   -0.47     0.75     0.9        0.23     0.48      -0.76     0.92
  2      9      -0.71   -1.68     2.74     3.29       0.75     1.72      -2.74     3.32
  2      10     -0.89   -2.07     3.39     4.07       0.92     2.13      -3.38     4.09
  2      11     -0.95   -2.19     3.57     4.29       0.96     2.24      -3.56     4.31
  2      12     -0.98   -2.22     3.63     4.37       0.96     2.28      -3.62     4.39
  2      13     -0.85   -1.89     3.08     3.72       0.81     1.94      -3.09     3.74
  2      14     -0.72   -1.61     2.61     3.15       0.69     1.65      -2.63     3.17
  2      15     -0.64   -1.47     2.38     2.87       0.64      1.5      -2.39     2.89
  2      16     -0.61   -1.41     2.29     2.75       0.62     1.44      -2.29     2.78
  3      1      -0.18   -0.12     -0.06    0.23       0.21     0.13      0.05      0.25
  3      2      -0.75   -0.46     -0.18    0.9        0.76     0.48      0.23      0.92
  3      3      -2.66   -1.63     -0.65    3.19       2.64     1.66      0.77      3.21
  3      4      -4.5    -2.74     -1.15    5.39       4.46     2.81      1.24      5.42
  3      5      -3.92   -2.39     -1.04    4.7        3.89     2.46      1.05      4.73
  3      6      -5.38   -3.3      -1.47    6.47       5.37     3.37      1.42       6.5
  3      7      -3.68   -2.26     -1.05    4.44       3.7      2.32      0.93      4.46
  3      8      -1.79   -1.12     -0.53    2.18       1.83     1.13      0.44       2.2
  3      9      -2.03   -1.25     -0.55    2.45       2.04     1.28      0.54      2.47
  3      10     -2.29   -1.41     -0.61    2.76       2.3      1.44      0.62      2.78
  3      11     -2.85   -1.75     -0.75    3.43       2.85     1.79      0.78      3.45
  3      12     -3.38   -2.07     -0.89    4.07       3.37     2.12      0.92      4.09
  3      13     -3.33   -2.04     -0.89    4.01       3.32     2.09      0.89      4.03
  3      14     -3.64   -2.23     -0.98    4.38       3.64     2.29      0.97       4.4
  3      15     -3.16   -1.94     -0.87    3.8        3.16     1.99      0.83      3.82
  3      16     -2.59   -1.6      -0.71    3.13       2.6      1.63      0.68      3.15
  4      1      1.15    -2.49     -4.04    4.88       -1.03    2.55      4.06       4.9
  4      2      0.54    -1.13     -1.81    2.2        -0.44    1.15      1.85      2.22
  4      3      0.26    -0.58     -0.94    1.13       -0.25     0.6      0.96      1.16
  4      4      0.21    -0.53     -0.86    1.03       -0.25    0.54      0.87      1.05
  4      5      0.71    -1.79     -2.91    3.49       -0.84    1.82      2.89      3.51
  4      6      1.13    -2.71     -4.44    5.33       -1.23    2.78       4.4      5.35
  4      7      1.33    -3.07     -5.02    6.03       -1.35    3.14      4.99      6.05
  4      8      1.51    -3.41     -5.56    6.69       -1.47    3.49      5.55      6.71
  4      9      0.89     -2       -3.26    3.92       -0.86    2.05      3.26      3.95
  4      10     0.71    -1.6      -2.6     3.13       -0.68    1.64      2.61      3.16
  4      11     0.64    -1.47     -2.39    2.88       -0.64    1.51       2.4       2.9
  4      12     0.62    -1.44     -2.34    2.81       -0.63    1.47      2.34      2.83
  4      13     0.76    -1.79     -2.91    3.5        -0.8     1.83      2.91      3.52
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  4      14     0.89    -2.06     -3.37    4.05       -0.92    2.12      3.36      4.07
  4      15     0.96    -2.19     -3.58    4.3        -0.96    2.25      3.57      4.32
  4      16     0.99    -2.25     -3.67    4.42       -0.98    2.31      3.67      4.45
  5      1      6.99    -8.52     1.85    11.18       -6.89    8.66      -1.86    11.22
  5      2       5.1    -6.21     1.42     8.16       -5.03    6.34      -1.31      8.2
  5      3      2.88    -3.55     0.88     4.65       -2.9     3.63      -0.68      4.7
  5      4      1.31    -1.69     0.44     2.18       -1.41     1.7      -0.29     2.23
  5      5      1.93    -2.47     0.54     3.18       -2.03    2.45      -0.52     3.22
  5      6      0.66    -0.87     0.13     1.1        -0.72    0.85      -0.24     1.14
  5      7      1.98    -2.43     0.43     3.17       -1.96    2.47      -0.62     3.21
  5      8      3.95    -4.79     0.96     6.28       -3.85    4.89      -1.11     6.33
  5      9      3.15    -3.85     0.84     5.05       -3.12    3.94      -0.84      5.1
  5      10     2.83    -3.47     0.77     4.55       -2.82    3.55      -0.74     4.59
  5      11     2.29    -2.82     0.65     3.69       -2.3     2.88      -0.59     3.73
  5      12     1.76    -2.19      0.5     2.86       -1.79    2.23      -0.46      2.9
  5      13     1.91    -2.37     0.52     3.09       -1.94    2.41      -0.51     3.13
  5      14     1.46    -1.81     0.38     2.35       -1.48    1.84      -0.41      2.4
  5      15     2.01    -2.47     0.51     3.22       -2.01    2.52      -0.57     3.27
  5      16     2.56    -3.13     0.66     4.1        -2.54     3.2      -0.7      4.14
  6      1      -0.32   -1.94     1.58     2.52       0.51     1.97      -1.56     2.57
  6      2       -1     -4.95     4.08     6.49       1.14     5.05      -3.98     6.54
  6      3      -1.15   -5.31     4.39     6.98       1.17     5.45      -4.29     7.03
  6      4      -1.4    -6.16     5.05     8.09       1.3      6.29      -4.99     8.13
  6      5      -0.77   -3.08      2.5     4.04       0.58     3.16      -2.52     4.09
  6      6      -0.42   -1.57     1.22     2.03       0.27     1.58      -1.32     2.07
  6      7      -0.2    -0.88     0.65     1.11       0.18     0.86      -0.75     1.16
  6      8      -0.11   -0.75     0.57     0.95       0.21     0.74      -0.63      1
  6      9      -0.47   -2.3      1.87      3         0.53     2.35      -1.87     3.05
  6      10     -0.66   -3.15     2.58     4.13       0.71     3.22      -2.55     4.17
  6      11     -0.72   -3.31     2.71     4.33       0.72     3.39      -2.68     4.38
  6      12     -0.77   -3.44     2.81     4.5        0.74     3.52      -2.79     4.55
  6      13     -0.62   -2.71     2.21     3.55       0.56     2.78      -2.21      3.6
  6      14     -0.49   -2.15     1.73     2.81       0.45      2.2      -1.76     2.85
  6      15     -0.42   -1.9      1.53     2.47       0.41     1.93      -1.56     2.51
  6      16     -0.36   -1.71     1.38     2.23       0.39     1.75      -1.4      2.27
  7      1      -0.31   -0.46     -0.11    0.57       0.41     0.44      0.09      0.61
  7      2      -0.61   -0.81     -0.12    1.02       0.68      0.8      0.22      1.07
  7      3      -1.98   -2.43     -0.43    3.16       1.96     2.46      0.62       3.2
  7      4      -3.74   -4.52     -0.91    5.93       3.64     4.63      1.05      5.98
  7      5      -2.5    -2.97     -0.65    3.93       2.4      3.11      0.66      3.98
  7      6      -4.85   -5.91     -1.35    7.77       4.79     6.04      1.25      7.81
  7      7      -2.87   -3.54     -0.88    4.64       2.9      3.63      0.68      4.69
  7      8      -1.21   -1.56     -0.41    2.02       1.31     1.58      0.27      2.07
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  7      9      -1.07   -1.33     -0.29    1.73       1.1      1.36      0.29      1.77
  7      10     -1.4    -1.74     -0.36    2.26       1.42     1.77      0.39      2.31
  7      11      -2     -2.46     -0.51    3.21       1.99     2.51      0.56      3.25
  7      12     -2.51   -3.07     -0.65    4.02       2.48     3.14      0.69      4.06
  7      13     -2.33   -2.83     -0.62    3.72       2.3      2.92      0.62      3.77
  7      14     -2.78   -3.4      -0.76    4.45       2.76     3.48      0.73       4.5
  7      15     -2.28   -2.8      -0.64    3.67       2.29     2.87      0.58      3.72
  7      16     -1.71   -2.13     -0.49    2.77       1.74     2.17      0.44      2.82
  8      1      1.04    -4.26     -3.45    5.58       -0.84    4.34      3.47      5.62
  8      2       0.4    -1.49     -1.15    1.93       -0.25     1.5      1.25      1.97
  8      3       0.2    -0.88     -0.65    1.11       -0.18    0.86      0.75      1.15
  8      4      0.12    -0.82     -0.62    1.04       -0.23    0.81      0.69      1.08
  8      5      0.52    -2.84     -2.31    3.7        -0.71    2.87      2.29      3.74
  8      6      0.96    -4.77     -3.94    6.25       -1.11    4.87      3.84       6.3
  8      7      1.15    -5.29     -4.37    6.96       -1.16    5.43      4.27      7.01
  8      8      1.49    -6.57     -5.38    8.62       -1.39     6.7      5.32      8.67
  8      9      0.68    -2.98     -2.42    3.9        -0.62    3.04      2.43      3.94
  8      10     0.48    -2.1      -1.7     2.75       -0.44    2.15      1.73      2.79
  8      11     0.41    -1.88     -1.52    2.45       -0.41    1.92      1.55       2.5
  8      12     0.37    -1.77     -1.43    2.3        -0.4     1.81      1.45      2.35
  8      13     0.53    -2.56     -2.09    3.34       -0.59    2.61      2.08      3.39
  8      14     0.65    -3.1      -2.54    4.07       -0.7     3.18      2.51      4.11
  8      15     0.72    -3.29     -2.7     4.32       -0.72    3.38      2.67      4.36
  8      16     0.78    -3.5      -2.86    4.58       -0.75    3.58      2.84      4.63
  9      1      4.71    -8.44     1.22     9.74       -4.5     8.63      -1.24     9.81
  9      2      3.46    -6.21      1       7.18       -3.32    6.39      -0.83     7.25
  9      3      2.28    -4.21     0.76     4.85       -2.3     4.32      -0.48     4.91
  9      4      1.37    -2.71      0.5     3.08       -1.54    2.73      -0.29     3.15
  9      5      2.02    -3.97     0.58     4.49       -2.23    3.94      -0.56     4.56
  9      6      0.92    -1.85     0.18     2.08       -1.06    1.83      -0.35     2.15
  9      7      1.77    -3.26     0.33     3.72       -1.75     3.3      -0.61     3.79
  9      8      2.86    -5.08     0.63     5.87       -2.69    5.22      -0.84     5.93
  9      9      2.26    -4.09     0.59     4.71       -2.2      4.2      -0.6      4.78
  9      10     2.03    -3.69     0.57     4.25       -1.99     3.8      -0.51     4.32
  9      11     1.73    -3.18     0.51     3.66       -1.73    3.27      -0.42     3.73
  9      12     1.43    -2.67     0.42     3.06       -1.48    2.73      -0.36     3.13
  9      13     1.58    -2.97     0.43     3.39       -1.64    3.02      -0.43     3.46
  9      14     1.23    -2.31     0.31     2.64       -1.27    2.36      -0.36     2.71
  9      15     1.56    -2.88     0.38     3.3        -1.56    2.94      -0.46     3.36
  9      16     1.89    -3.42     0.47     3.93       -1.84    3.51      -0.53      4
  10     1      -0.26   -2.83     1.54     3.23       0.54     2.87      -1.52     3.29
  10     2      -0.67   -5.37     3.01     6.19       0.88      5.5      -2.84     6.25
  10     3      -0.76   -5.28     2.99     6.12       0.78     5.46      -2.79     6.18
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  10     4      -0.99   -6.16     3.43     7.12       0.82     6.33      -3.29     7.19
  10     5      -0.66   -3.57     1.94     4.11       0.38     3.68      -1.95     4.18
  10     6      -0.46   -2.46     1.24     2.79       0.25     2.47      -1.4      2.85
  10     7      -0.29   -2.01     0.97     2.25       0.28     1.98      -1.17     2.32
  10     8      -0.15   -1.64      0.8     1.83       0.32     1.62      -0.94      1.9
  10     9      -0.35   -2.72     1.48     3.12       0.44     2.79      -1.48     3.19
  10     10     -0.47   -3.47     1.92      4         0.54     3.57      -1.87     4.06
  10     11     -0.51   -3.5      1.94     4.03       0.51     3.61      -1.88      4.1
  10     12     -0.56   -3.66     2.02     4.22       0.51     3.77      -1.98     4.29
  10     13     -0.48   -3.01     1.64     3.46       0.4       3.1      -1.64     3.53
  10     14     -0.41   -2.57     1.37     2.94       0.34     2.63      -1.42     3.01
  10     15     -0.35   -2.41     1.28     2.75       0.35     2.46      -1.34     2.82
  10     16     -0.29   -2.18     1.16     2.49       0.34     2.23      -1.2      2.56
  11     1      -0.52   -1.17     -0.17    1.29       0.72     1.14      0.16      1.36
  11     2      -0.85   -1.73     -0.16    1.93       0.99     1.71      0.33       2
  11     3      -1.72   -3.16     -0.31    3.61       1.7      3.21       0.6      3.68
  11     4      -2.64   -4.69     -0.57    5.41       2.47     4.82      0.78      5.48
  11     5      -1.75   -2.98     -0.43    3.48       1.55     3.16      0.45      3.55
  11     6      -3.26   -5.84     -0.95    6.75       3.12     6.01      0.77      6.82
  11     7      -2.22   -4.09     -0.74    4.71       2.23      4.2      0.46      4.78
  11     8      -1.25   -2.48     -0.47    2.82       1.42      2.5      0.26      2.89
  11     9      -0.92   -1.75     -0.26    1.99       0.98      1.8      0.25      2.06
  11     10     -1.16   -2.18     -0.29    2.49       1.2      2.23      0.34      2.55
  11     11     -1.52   -2.79     -0.36    3.2        1.51     2.86      0.45      3.26
  11     12     -1.81   -3.27     -0.45    3.77       1.76     3.37      0.51      3.83
  11     13     -1.63   -2.92     -0.43    3.37       1.57     3.03      0.43      3.44
  11     14     -1.96   -3.56     -0.55    4.1        1.92     3.67      0.49      4.17
  11     15     -1.68   -3.1      -0.49    3.56       1.69     3.18      0.41      3.63
  11     16     -1.35   -2.53     -0.4     2.89       1.4      2.59      0.34      2.96
  12     1      0.83    -4.66     -2.52    5.36       -0.55    4.76      2.54      5.43
  12     2      0.44    -2.34     -1.17    2.65       -0.24    2.35      1.34      2.72
  12     3      0.29    -1.98     -0.95    2.22       -0.28    1.95      1.15      2.28
  12     4      0.16    -1.75     -0.86    1.96       -0.34    1.73       1        2.02
  12     5       0.4    -3.75     -2.03    4.29       -0.69     3.8      2.02      4.35
  12     6      0.64    -5.13     -2.88    5.92       -0.85    5.27      2.71      5.99
  12     7      0.76    -5.22     -2.96    6.04       -0.77     5.4      2.75      6.11
  12     8      1.05    -6.54     -3.64    7.56       -0.88    6.72       3.5      7.62
  12     9      0.52    -3.25     -1.77    3.74       -0.43    3.34      1.77       3.8
  12     10     0.39    -2.47     -1.32    2.83       -0.33    2.53      1.37       2.9
  12     11     0.34    -2.35     -1.24    2.68       -0.34     2.4       1.3      2.75
  12     12     0.29    -2.21     -1.18    2.52       -0.35    2.26      1.22      2.59
  12     13     0.39    -2.96     -1.61    3.39       -0.47    3.03      1.61      3.46
  12     14     0.46    -3.37     -1.86    3.88       -0.52    3.47      1.81      3.95
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  12     15      0.5    -3.44     -1.91    3.96       -0.5     3.55      1.85      4.03
  12     16     0.57    -3.69     -2.03    4.25       -0.51     3.8      1.99      4.32
  13     1      12.36   -29.42     3.2    32.07   -11.73      30.06      -3.23    32.43
  13     2      10.63   -25.47    3.07    27.77       -10.2   26.09      -2.57    28.13
  13     3      7.07    -17.36    2.31    18.89       -7.1    17.82      -1.54    19.25
  13     4      3.41    -8.97     1.27     9.68       -3.9     9.23      -0.71    10.04
  13     5      2.79    -7.66     0.85     8.19       -3.42     7.8      -0.82     8.55
  13     6      2.21    -5.97      0.4     6.38       -2.64    6.13      -0.9      6.74
  13     7      4.55    -11.1     0.81    12.02       -4.52   11.42      -1.58    12.38
  13     8      8.34    -19.78    1.86    21.55       -7.85   20.31      -2.42    21.91
  13     9      6.49    -15.65    1.71    17.03       -6.31   16.12      -1.72    17.39
  13     10     6.18    -14.95    1.72    16.27       -6.05   15.41      -1.57    16.63
  13     11     5.42    -13.28    1.57    14.43       -5.43   13.69      -1.34    14.79
  13     12     4.34    -10.81    1.27    11.72       -4.49   11.16      -1.1     12.08
  13     13      4.2    -10.51    1.15    11.38       -4.39   10.83      -1.15    11.74
  13     14      3.9     -9.7     0.99     10.5       -4.03   10.02      -1.14    10.86
  13     15      4.7    -11.47    1.14    12.45       -4.69   11.84      -1.37    12.81
  13     16     5.73    -13.83    1.43    15.04       -5.59   14.26      -1.6      15.4
  14     1      -0.83   -11.36    4.65     12.3       1.6     11.67      -4.62    12.66
  14     2      -1.8    -19.35    8.17    21.09       2.36    19.88      -7.68    21.44
  14     3      -2.47   -22.72    9.63     24.8       2.49    23.36       -9      25.16
  14     4      -2.78   -22.86    9.57    24.93       2.28    23.47      -9.14    25.29
  14     5      -2.01   -14.68    5.98    15.98       1.24    15.14      -6.01    16.34
  14     6      -1.31    -9.3     3.54    10.03       0.75     9.55      -4.03    10.39
  14     7      -0.7    -6.25     2.22     6.67       0.67     6.39      -2.85     7.03
  14     8      -0.43   -6.33     2.36     6.76       0.93     6.49      -2.79     7.12
  14     9      -1.15   -11.6     4.75    12.58       1.38    11.96      -4.74    12.94
  14     10     -1.42   -13.76     5.7    14.96       1.59    14.19      -5.56    15.32
  14     11     -1.58   -14.43     6       15.7       1.58    14.89      -5.81    16.06
  14     12     -1.66   -14.47    5.99    15.75       1.51    14.93      -5.86    16.11
  14     13     -1.5    -12.57    5.14    13.66       1.26    12.98      -5.15    14.02
  14     14     -1.28   -10.9     4.38    11.81       1.11    11.25      -4.53    12.17
  14     15     -1.09   -9.93     3.96    10.75       1.08    10.25      -4.15    11.11
  14     16      -1     -9.85     3.96    10.66       1.15    10.17      -4.09    11.02
  15     1      -1.42   -4.26     -0.48    4.51       2.05      4.4      0.45      4.87
  15     2      -2.01   -5.47     -0.34    5.83       2.44     5.63      0.84      6.19
  15     3      -4.33   -10.57    -0.76   11.45       4.3     10.89      1.53     11.81
  15     4      -8.14   -19.29    -1.81   21.01       7.65    19.82      2.36     21.37
  15     5      -8.44   -19.81    -2.16   21.64       7.81    20.45      2.19     21.99
  15     6     -10.02   -23.96    -2.9    26.13       9.59    24.58       2.4     26.49
  15     7      -6.79   -16.66    -2.23   18.13       6.82    17.12      1.46     18.49
  15     8      -3.29   -8.69     -1.24    9.37       3.78     8.94      0.68      9.73
  15     9      -3.4    -8.53     -0.94    9.23       3.59     8.84      0.93      9.59
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at   Ft at    Fx at       Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base    Base    Attach.     Attach.   Attach.   Attach.
                 KN      KN        KN      KN       KN          KN        KN        KN
  15     10     -3.74    -9.3     -0.94   10.07       3.87     9.63      1.09     10.43
  15     11     -4.58   -11.19    -1.11   12.14       4.57    11.56      1.34      12.5
  15     12     -5.64   -13.61    -1.4    14.79       5.49    14.04      1.57     15.15
  15     13     -5.72   -13.74    -1.5    14.96       5.53    14.21      1.51     15.32
  15     14     -6.02   -14.56    -1.67   15.85       5.89    15.02      1.52     16.21
  15     15     -5.31   -12.99    -1.54   14.12       5.32     13.4      1.31     14.48
  15     16     -4.25   -10.58    -1.25   11.47       4.4     10.93      1.08     11.83
  16     1       2.2    -16.16    -6.58   17.58       -1.42   16.62      6.61     17.94
  16     2      1.26    -8.89     -3.37    9.59       -0.71    9.14      3.86      9.95
  16     3      0.69    -6.17     -2.19    6.59       -0.66    6.31      2.82      6.95
  16     4      0.44     -6.4     -2.39    6.84       -0.94    6.56      2.82       7.2
  16     5        1     -12.81    -5.23   13.87       -1.77   13.12      5.21     14.23
  16     6      1.74    -18.75    -7.92   20.43       -2.3    19.27      7.43     20.78
  16     7      2.45    -22.55    -9.55   24.61       -2.48   23.19      8.93     24.97
  16     8       2.8    -23.04    -9.64   25.13       -2.3    23.66      9.21     25.49
  16     9      1.53    -12.87    -5.26   13.99       -1.3    13.28      5.27     14.35
  16     10     1.25    -10.65    -4.28   11.55       -1.09     11       4.43     11.91
  16     11     1.08     -9.8     -3.91    10.6       -1.07   10.11       4.1     10.96
  16     12       1     -9.79     -3.94    10.6       -1.15   10.11      4.07     10.96
  16     13     1.19    -11.9     -4.87   12.91       -1.42   12.27      4.86     13.27
  16     14     1.39    -13.52    -5.6     14.7       -1.56   13.95      5.46     15.06
  16     15     1.56    -14.29    -5.95   15.56       -1.57   14.76      5.76     15.92
  16     16     1.66    -14.42    -5.96   15.69       -1.51   14.88      5.84     16.05
  17     1      20.05   -53.06     5.2    56.96   -19.13      54.06      -5.23    57.58
  17     2      18.44   -49.19    5.28     52.8   -17.81      50.16      -4.57    53.42
  17     3      10.85   -29.58    3.53    31.71   -10.88      30.35      -2.45    32.33
  17     4      3.54    -10.55    1.45    11.22       -4.24   11.04      -0.67    11.84
  17     5      1.81    -6.11     0.62     6.4        -2.72    6.45      -0.59     7.03
  17     6      2.11    -6.56     0.29     6.89       -2.75    6.93       -1       7.52
  17     7      5.58    -15.07    0.91    16.09       -5.54   15.65      -1.99    16.72
  17     8      13.47   -35.59    3.04    38.18   -12.77      36.44      -3.82     38.8
  17     9      9.89    -26.47     2.6    28.38       -9.61   27.24      -2.61    29.01
  17     10     9.58    -25.77    2.66    27.62       -9.39   26.52      -2.44    28.24
  17     11     7.93    -21.57     2.3    23.09       -7.94   22.26      -1.98    23.72
  17     12     5.55    -15.31    1.64    16.37       -5.76   15.93      -1.4     16.99
  17     13     4.56    -12.71    1.27    13.57       -4.84   13.28      -1.26    14.19
  17     14      4.7    -12.95    1.17    13.83       -4.89   13.53      -1.39    14.45
  17     15     6.36    -17.22    1.53    18.42       -6.35   17.86      -1.85    19.04
  17     16     8.59    -23.04    2.14    24.68       -8.38   23.76      -2.38    25.31
  18     1      -1.04   -16.58    6.13    17.71       2.12    17.16      -6.1     18.34
  18     2      -2.74   -32.73    12.43   35.12       3.52    33.58     -11.73    35.75
  18     3      -4.43   -45.39    17.21   48.74       4.46    46.39     -16.29    49.37
  18     4      -4.61   -42.39    15.93   45.52       3.9     43.36     -15.29    46.14
ASMTower 2018.4         Job No.      40m Guyed Pole                       Rev. No.          A
                        Client       OG                                   Date              5/11/2017
                        Project      GSM Network                          Designed by       M.Joe
                                                                          Checked by        A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at   Fy at     Fz at    Ft at    Fx at      Fy at     Fz at     Ft at
 No.    No.     Base    Base      Base     Base    Attach.    Attach.   Attach.   Attach.
                 KN      KN        KN       KN       KN         KN        KN        KN
  18     5      -3.18   -26.04    9.55     27.92      2.1     26.81      -9.58    28.55
  18     6      -1.66   -12.57    4.27     13.38      0.88    13.07      -4.97    14.01
  18     7      -0.66   -6.45     1.93     6.77       0.63     6.79      -2.84     7.39
  18     8      -0.39   -7.66     2.52     8.07       1.1      8.03      -3.15      8.7
  18     9      -1.59   -17.82    6.58     19.06      1.91    18.46      -6.57    19.69
  18     10     -2.08   -22.44    8.37     24.04      2.32    23.16      -8.16    24.67
  18     11     -2.47   -25.14     9.4     26.96      2.48    25.91      -9.13    27.59
  18     12     -2.54   -24.57    9.14     26.33      2.33    25.33      -8.95    26.96
  18     13     -2.22   -20.69    7.62     22.16      1.89    21.39      -7.63    22.79
  18     14     -1.74   -16.31    5.91     17.43      1.5     16.93      -6.12    18.06
  18     15     -1.31   -13.13    4.72     14.01      1.3      13.7      -4.99    14.64
  18     16     -1.27   -13.92    5.05     14.86      1.48     14.5      -5.24    15.49
  19     1      -1.5    -5.25     -0.54    5.49       2.41      5.6      0.51      6.11
  19     2      -1.97   -6.15     -0.25    6.47       2.6      6.53      0.96      7.09
  19     3      -5.42   -14.64    -0.87    15.63      5.39    15.21      1.95     16.26
  19     4     -13.83   -36.55    -3.13    39.2    13.13      37.39      3.91     39.82
  19     5     -17.93   -47.36    -4.64    50.86   17.02      48.36      4.67     51.48
  19     6     -17.58   -46.87    -5.04    50.31   16.95      47.83      4.33     50.93
  19     7     -10.61   -28.93    -3.47    31.01   10.64       29.7      2.38     31.63
  19     8      -3.68   -10.94    -1.49    11.63      4.38    11.43      0.71     12.26
  19     9      -4.29   -11.96    -1.19    12.76      4.56    12.53      1.18     13.39
  19     10     -4.63   -12.77    -1.16    13.64      4.82    13.35      1.37     14.26
  19     11     -6.38   -17.29    -1.54    18.49      6.37    17.93      1.86     19.12
  19     12     -8.75   -23.47    -2.19    25.14      8.54    24.19      2.42     25.77
  19     13     -9.61   -25.73    -2.53    27.58      9.34     26.5      2.54     28.21
  19     14     -9.51   -25.59    -2.64    27.42      9.32    26.35      2.43     28.05
  19     15     -7.96   -21.64    -2.31    23.17      7.97    22.33      1.98      23.8
  19     16     -5.7    -15.74    -1.68    16.83      5.91    16.36      1.45     17.45
  20     1      3.24    -26.52    -9.72    28.43      -2.16   27.28      9.75     29.05
  20     2      1.63    -12.24    -4.15    13.03      -0.85   12.74      4.85     13.66
  20     3      0.66    -6.46     -1.93    6.77       -0.63     6.8      2.85       7.4
  20     4      0.38    -7.51     -2.46    7.92       -1.09    7.89      3.09      8.54
  20     5      1.11    -17.22    -6.36    18.39      -2.19   17.79      6.33     19.01
  20     6       2.7    -32.19    -12.23   34.54      -3.48   33.04     11.53     35.17
  20     7      4.44    -45.44    -17.23   48.8       -4.47   46.44     16.31     49.42
  20     8      4.55    -41.81    -15.71   44.9       -3.84   42.78     15.08     45.53
  20     9      2.25    -21.04    -7.74    22.53      -1.93   21.74      7.75     23.16
  20     10     1.74    -16.34    -5.92    17.47      -1.51   16.96      6.13      18.1
  20     11     1.33    -13.31    -4.78    14.21      -1.32   13.88      5.05     14.83
  20     12     1.27    -13.99    -5.07    14.93      -1.49   14.57      5.26     15.56
  20     13     1.62    -18.16     -6.7    19.42      -1.94    18.8      6.69     20.05
  20     14     2.09    -22.47    -8.39    24.08      -2.32    23.2      8.18      24.7
  20     15     2.49    -25.32    -9.46    27.15      -2.5    26.09      9.19     27.77
ASMTower 2018.4              Job No.      40m Guyed Pole                                   Rev. No.           A
                             Client       OG                                               Date               5/11/2017
                             Project      GSM Network                                      Designed by        M.Joe
                                                                                           Checked by         A.S.M
ASMTower 2018.4
 Wire Comb.     Fx at         Fy at    Fz at     Ft at       Fx at         Fy at       Fz at         Ft at
 No.    No.     Base          Base     Base      Base       Attach.       Attach.     Attach.       Attach.
                 KN            KN       KN        KN          KN            KN          KN            KN
  20        16       2.55    -24.63    -9.16     26.4        -2.33        25.39            8.97      27.03
Reactions From The Tower
Total reaction on foundation
  Comb           Shear X    Vertical   Shear Z     Horiz.      Moment          Torque             Moment        Horiz.
   No.             KN         KN         KN        Shear         Mx              My                 Mz         Moment
                                                    KN          KN.m            KN.m               KN.m         KN.m
       1          53.48      47.77      1.83       53.51         69.54              0.72          -1416.14     1417.85
       2          34.53      47.77      32.38      47.34        860.65            -1.91           -947.54      1280.06
       3          2.61       47.77      38.78      38.86       1047.03            -2.24           -100.25      1051.81
       4         -31.88      47.77      29.33      43.33        759.06            -4.91           866.88       1152.24
       5         -28.14      47.77      -1.29      28.17        -49.76            -2.04           826.08       827.58
       6         -32.13      47.77     -30.35      44.19        -800.73             2.76          874.06       1185.39
       7          -1.62      47.77     -38.38      38.41       -1033.01             3.65            65         1035.06
       8          32.75      47.77     -29.99      44.41        -767.12             4.16          -877.03      1165.19
       9          16.06      40.64      0.55       16.06         20.2               0.24          -424.33      424.82
       10         10.37      40.64      9.73       14.22        258.09              -0.6          -283.78      383.59
       11         0.78       40.64      11.65      11.68         314.4            -0.66            -29.15      315.75
       12         -9.58      40.64      8.81       13.01        227.67            -1.48           261.39       346.64
       13         -9.06      40.64      -0.39      9.07         -15.47              -0.6          261.15       261.61
       14         -9.65      40.64      -9.12      13.28        -241.34             0.8           263.53       357.35
       15         -0.48      40.64     -11.54      11.55        -311.38             1.1            20.33       312.04
       16         9.84       40.64      -9.01      13.34        -231.25             1.24          -262.71      349.99
   Max.           53.48      47.77      38.78      53.51       1047.03            -4.91           -1416.14     1417.85
Individual support reaction
   Joint         Comb         Rx         Ry         Rz           RMx              RMy              RMz
    No.           No.         KN         KN         KN           KN.m             KN.m             KN.m
   Pole            1         0.99      250.87      -0.01              0             0.81             0
                   2         0.64      244.12      0.61               0           -1.99              0
                   3         0.04      234.98       0.7               0           -2.21              0
                   4         -0.57     238.48      0.55               0           -4.92              0
                   5         -0.32     232.57      -0.01              0           -2.01              0
                   6         -0.57     240.02      -0.57              0             2.69             0
                   7         0.01      234.47       -0.7              0             3.68             0
                   8         0.64       238.8      -0.57              0             4.14             0
                   9         0.44      196.18        0                0             0.24             0
                   10        0.26      196.23      0.24               0             -0.6             0
                   11        0.02      196.26      0.25               0           -0.66              0
                   12         -0.2     196.26      0.22               0           -1.48              0
ASMTower 2018.4        Job No.      40m Guyed Pole                  Rev. No.      A
                       Client       OG                              Date          5/11/2017
                       Project      GSM Network                     Designed by   M.Joe
                                                                    Checked by    A.S.M
ASMTower 2018.4
   Joint      Comb     Rx          Ry       Rz       RMx    RMy         RMz
    No.         No.    KN          KN       KN       KN.m   KN.m        KN.m
               13     -0.13      196.33      0        0     -0.6          0
               14      -0.2      196.24    -0.22      0     0.81          0
               15     0.02       196.26    -0.25      0     1.1           0
               16     0.25       196.26    -0.23      0     1.24          0
              Max     0.99       250.87     0.7       0     -4.92         0
   Guy         1      50.96      -103.65   13.29      0      0            0
  @15m
 165Deg        2      43.17      -90.49    12.28      0      0            0
               3      26.73      -56.95     8.53      0      0            0
               4      11.46      -25.06     4.21      0      0            0
               5      10.56      -21.45     3.13      0      0            0
               6      6.76       -15.77     1.2       0      0            0
               7      16.51      -33.48     3.12      0      0            0
               8      33.19      -68.03     7.66      0      0            0
               9      25.72      -52.48     6.79      0      0            0
               10     24.3       -50.13     6.7       0      0            0
               11     20.52      -42.77     5.89      0      0            0
               12     15.68      -32.58     4.54      0      0            0
               13     14.87      -30.18     4.08      0      0            0
               14     13.62       -28.2     3.46      0      0            0
               15     17.47      -35.78     4.29      0      0            0
               16     22.17       -45.5     5.59      0      0            0
              Max     50.96      -103.65   13.29      0      0            0
   Guy         1        -3       -34.12    16.22      0      0            0
  @15m
  75Deg        2      -7.37      -65.16    32.21      0      0            0
               3      -10.14     -81.77    39.22      0      0            0
               4      -11.25     -80.85    39.33      0      0            0
               5      -7.59      -49.45    23.36      0      0            0
               6       -4.4      -27.06    12.14      0      0            0
               7       -2.1      -16.17     6.7       0      0            0
               8      -1.26      -16.84      7        0      0            0
               9      -4.27      -36.12    17.42      0      0            0
               10     -5.53       -44.9    21.96      0      0            0
               11     -6.23      -48.56    23.61      0      0            0
               12     -6.51      -48.36    23.58      0      0            0
               13     -5.66      -40.88    19.68      0      0            0
               14     -4.63      -33.54    16.01      0      0            0
               15     -3.81      -28.84    13.87      0      0            0
               16     -3.52      -29.06    13.84      0      0            0
              Max     -11.25     -81.77    39.33      0      0            0
   Guy         1      -3.93      -11.26    -1.36      0      0            0
  @15m
 345Deg        2       -6.2      -14.62    -1.05      0      0            0
               3      -16.1      -32.43    -3.01      0      0            0
               4      -32.84     -67.79    -7.57      0      0            0
ASMTower 2018.4          Job No.      40m Guyed Pole                            Rev. No.         A
                         Client       OG                                        Date             5/11/2017
                         Project      GSM Network                               Designed by      M.Joe
                                                                                Checked by       A.S.M
ASMTower 2018.4
   Joint      Comb       Rx          Ry         Rz          RMx          RMy            RMz
    No.         No.      KN          KN         KN          KN.m         KN.m           KN.m
               5        -34.53      -75.51      -8.92        0            0              0
               6        -41.08      -85.87      -11.7        0            0              0
               7        -26.16      -55.49      -8.37        0            0              0
               8        -11.22      -24.79      -4.15        0            0              0
               9        -11.71      -24.81      -3.23        0            0              0
               10       -13.23      -27.4       -3.36        0            0              0
               11       -17.34      -35.47      -4.26        0            0              0
               12       -22.1       -45.49      -5.57        0            0              0
               13       -22.62      -47.27      -5.97        0            0              0
               14       -23.91      -49.34      -6.6         0            0              0
               15       -20.38      -42.46      -5.85        0            0              0
               16       -15.61      -32.57      -4.52        0            0              0
              Max       -41.08      -85.87      -11.7        0            0              0
   Guy         1         8.46       -54.07     -26.31        0            0              0
  @15m
 255Deg        2         4.28       -26.09     -11.66        0            0              0
               3         2.1        -16.07      -6.66        0            0              0
               4         1.31       -17.01      -7.19        0            0              0
               5         3.74       -38.4      -18.85        0            0              0
               6         7.17       -63.55     -31.41        0            0              0
               7        10.12       -81.57     -39.13        0            0              0
               8        11.41       -81.37     -39.93        0            0              0
               9         5.88       -42.14     -20.44        0            0              0
               10        4.58       -33.17     -15.81        0            0              0
               11        3.8        -28.82     -13.84        0            0              0
               12        3.55       -29.19     -13.95        0            0              0
               13        4.48       -37.37     -18.18        0            0              0
               14        5.48       -44.53     -21.77        0            0              0
               15        6.22       -48.54     -23.59        0            0              0
               16        6.54       -48.49     -23.69        0            0              0
              Max       11.41       -81.57     -39.93        0            0              0
Comparison of Reaction Force Vs. Applied Loads
Base moment reaction Vs. applied base moment
  Comb      Reaction   Reaction    Reaction   Applied OTM    Applied     Applied OTM           Change %
   No.       OTM X      Torque      OTM Z          X         Torque            Z
             KN.m        KN.m       KN.m         KN.m         KN.m          KN.m
    1        69.54       0.72      -1416.14      -69.33          -0.81        1411.41           0.3352
    2        860.65     -1.91      -947.54      -857.87          1.99         944.41            0.3288
    3       1047.03     -2.24      -100.25     -1043.55          2.21         100.08            0.3324
    4        759.06     -4.91       866.88      -756.53          4.92         -864.06           0.3296
    5        -49.76     -2.04       826.08       49.63           2.01         -823.07           0.3649
ASMTower 2018.4              Job No.            40m Guyed Pole                                 Rev. No.            A
                             Client             OG                                             Date                5/11/2017
                             Project            GSM Network                                    Designed by         M.Joe
                                                                                               Checked by          A.S.M
ASMTower 2018.4
  Comb      Reaction       Reaction      Reaction         Applied OTM       Applied     Applied OTM          Change %
   No.       OTM X          Torque        OTM Z                X            Torque            Z
              KN.m           KN.m         KN.m               KN.m            KN.m          KN.m
    6        -800.73         2.76             874.06          798.11          -2.69        -871.16                0.3307
    7        -1033.01        3.65              65            1029.55          -3.68        -64.89                 0.3356
    8        -767.12         4.16          -877.03            764.55          -4.14        874.23                 0.3275
    9          20.2          0.24          -424.33            -20.19          -0.24        423.45                 0.2085
    10        258.09         -0.6          -283.78            -257.54          0.6         283.18                 0.2142
    11        314.4         -0.66             -29.15          -313.69         0.66             29.12              0.2262
    12        227.67        -1.48             261.39          -227.16         1.48         -260.81                0.224
    13        -15.47         -0.6             261.15           15.45           0.6         -260.5                 0.2489
    14       -241.34         0.8              263.53           240.8          -0.81        -262.96                0.2228
    15       -311.38         1.1              20.33           310.66          -1.1             -20.3              0.232
    16       -231.25         1.24          -262.71            230.72          -1.24        262.14                 0.2233
Force reaction Vs. applied forces
  Comb       Reaction      Reaction      Reaction          Applied       Applied      Applied          Error %
   No.       Shear X       Vertical      Shear Z           Shear X       Vertical     Shear Z
               KN            KN            KN                KN            KN           KN
    1         53.48         47.77              1.83         -53.48        -47.77       -1.83             0
    2         34.53         47.77             32.38         -34.53        -47.77      -32.38             0
    3          2.61         47.77             38.78          -2.61        -47.77      -38.78             0
    4         -31.88        47.77             29.33          31.88        -47.77      -29.33             0
    5         -28.14        47.77             -1.29          28.14        -47.77       1.29              0
    6         -32.13        47.77             -30.35         32.13        -47.77       30.35             0
    7         -1.62         47.77             -38.38          1.62        -47.77       38.38             0
    8         32.75         47.77             -29.99        -32.75        -47.77       29.99             0
    9         16.06         40.64              0.55         -16.06        -40.64       -0.55             0
    10        10.37         40.64              9.73         -10.37        -40.64       -9.73             0
    11         0.78         40.64             11.65          -0.78        -40.64      -11.65             0
    12        -9.58         40.64              8.81           9.58        -40.64       -8.81             0
    13        -9.06         40.64             -0.39           9.06        -40.64       0.39              0
    14        -9.65         40.64             -9.12           9.65        -40.64       9.12              0
    15        -0.48         40.64             -11.54          0.48        -40.64       11.54             0
    16         9.84         40.64             -9.01          -9.84        -40.64       9.01              0
Displacement at non service condition
 Elevation   Deflection X           Down              Deflection Z        Horiz.          Tilt                   Twist
    m            mm                  mm                   mm            Deflection        Deg                     My
                                                                           mm                                     Deg
    45        243.9 (5)            -5.5 (1)            208.9 (7)        244.2 (5)        1.51 (5)            1.1 (4)
    40        -139.6 (1)           -5.5 (1)            -111.8 (3)       140.1 (1)        1.35 (5)            1.1 (4)
    36         -94.6 (1)           -5.2 (1)             -59.6 (3)         95 (1)         0.83 (5)            1.02 (4)
    27         -81 (1)             -4.1 (1)             -41.9 (2)        81.1 (1)        0.03 (3)            0.81 (4)
    18         -57.3 (1)           -2.9 (1)             30.7 (8)         57.3 (1)        0.26 (1)            0.56 (4)
    9          -19.1 (1)           -1.5 (1)             10.1 (7)         19.1 (1)        0.18 (1)            0.29 (4)
ASMTower 2018.4              Job No.          40m Guyed Pole                               Rev. No.       A
                             Client           OG                                           Date           5/11/2017
                             Project          GSM Network                                  Designed by    M.Joe
                                                                                           Checked by     A.S.M
ASMTower 2018.4
Displacement at service condition
 Elevation   Deflection X          Down         Deflection Z        Horiz.               Tilt          Twist
    m            mm                 mm              mm            Deflection             Deg            My
                                                                     mm                                 Deg
    45            58 (13)         -4.3 (13)      52.3 (15)        58.1 (13)         0.38 (13)         0.33 (12)
    40         -29.3 (9)          -4.3 (13)      25.3 (15)         29.3 (9)         0.33 (13)         0.33 (12)
    36         -18.6 (9)          -4.1 (13)      -12.6 (11)        18.7 (9)         0.18 (13)         0.31 (12)
    27         -16.8 (9)          -3.2 (13)       -9.6 (10)        16.8 (9)         0.02 (13)         0.24 (12)
    18            -12 (9)         -2.2 (13)       -6.8 (10)         12 (9)              0.05 (9)      0.17 (12)
     9            -4.7 (9)        -1.2 (13)       2.9 (15)         4.7 (9)              0.04 (9)      0.09 (12)
                                  DESIGN OF ANCHOR ROD
Name: BaseConn
Design is safe with usage ratio 0.18
Connection Parameters
Located at: Pole.
   Design code                                                          =     ANSI/TIA-222-G-2
   Diameter of base plate                                               =     360               mm
   Type of bolt analysis                                                =     Elastic
   Dist. above concrete to bottom of leveling nut                       =     75                mm
   Orientation of the connection                                        =     0                 Deg
   Location of support reaction                               X         =     0                 mm
                                                              Z         =     0                 mm
   Use of grout under base plate                                        =     YES
   Use of leveling nut under base plate                                 =     NO
   Total length of anchor rod                                           =     600               mm
ASMTower 2018.4                   Job No.         40m Guyed Pole                     Rev. No.      A
                                  Client          OG                                 Date          5/11/2017
                                  Project         GSM Network                        Designed by   M.Joe
                                                                                     Checked by    A.S.M
ASMTower 2018.4
Bolt Specification
 #    Diam         X-Coord. Z-Coord.            Material
      mm             mm       mm                 Name
 1     16            155           0            A572-50
 2     16            77.5        134.2          A572-50
 3     16           -77.5        134.2          A572-50
 4     16            -155          0            A572-50
 5     16           -77.5        -134.2         A572-50
 6     16            77.5        -134.2         A572-50
Critical Reaction in Global Coordinate System
 #      Support             Load          Fx           Fy      Fz      Horiz.    Mx        My         Mz        Horiz.
                            Com.          KN           KN      KN      Force    KN.m      KN.m       KN.m      Moment
                                                                        KN                                      KN.m
 1          Pole             4          -0.57        238.48    0.55     0.8      0         -4.92       0         0
Critical Action in Local Coordinates of Connection
 #      Support             Load          Fx           Fy      Fz      Horiz.    Mx        My         Mz        Horiz.
                            Com.          KN           KN      KN      Force    KN.m      KN.m       KN.m      Moment
                                                                        KN                                      KN.m
 1          Pole             4           0.57        -238.48   -0.55    0.8      0         4.92        0         0
Force distribution in anchor rods
 #    Diam           Fx            Fy           Fz
      mm             #1            #1           #1
                     KN            KN           KN
ASMTower 2018.4                 Job No.        40m Guyed Pole                  Rev. No.            A
                                Client         OG                              Date                5/11/2017
                                Project        GSM Network                     Designed by         M.Joe
                                                                               Checked by          A.S.M
ASMTower 2018.4
 #   Diam           Fx          Fy        Fz
      mm            #1          #1        #1
                    KN          KN        KN
 1       16         0.1       -39.75      -5.39
 2       16        4.68       -39.75      -2.74
 3       16        4.68       -39.75      2.56
 4       16         0.1       -39.75      5.2
 5       16        -4.49      -39.75      2.56
 6       16        -4.49      -39.75      -2.74
Bolt Design
     Anchor rod diameter                                 d      =   16            mm
     Material of anchor rod                                     =   A572-50
     Gross area of anchor rod                            Ag     =   201.1         mm2
     Net area of anchor rod                              An     =   150.8         mm2
     Minimum tensile strength of anchor rod              Fu     =   448.2         MPa
     Minimum yield strength of anchor rod                Fy     =   344.7         MPa
     Maximum compression                                 Puc    =   41.81         KN
     Maximum tension                                     Put    =   0             KN
     Considered axial force in interaction 1             Pu1    =   0             KN
     Shear force in interaction 1                        Vu1    =   5.42          KN
     Nominal tensile strength of anchor rod              Rnt    =   67.58         KN
                                                         φ      =   0.8
                                                         η      =   0.55
     Interaction equation                                       =   [ Pu1 + ( Vu1 / η ) ] / φRnt
                                                                =   0.18
     Bolt status                                                    Safe as 0.18 < 1.0
                                    DESIGN OF ANCHOR ROD
Name: Guy Base
Design is safe with usage ratio 0.86
Connection Parameters
Located at: Guy @15m 165Deg, Guy @15m 75Deg, Guy @15m 345Deg and Guy @15m 255Deg.
ASMTower 2018.4               Job No.         40m Guyed Pole                 Rev. No.      A
                              Client          OG                             Date          5/11/2017
                              Project         GSM Network                    Designed by   M.Joe
                                                                             Checked by    A.S.M
ASMTower 2018.4
     Design code                                               =   ANSI/TIA-222-G-2
     Width of base plate                                       =   300         mm
     Height of base plate                                      =   400         mm
     Type of bolt analysis                                     =   Elastic
     Dist. above concrete to bottom of leveling nut            =   50          mm
     Orientation of the connection                             =   90          Deg
     Location of support reaction                       X      =   0           mm
                                                        Z      =   0           mm
     Use of grout under base plate                             =   YES
     Use of leveling nut under base plate                      =   YES
     Total length of anchor rod                                =   800         mm
Bolt Specification
 #     Diam     X-Coord. Z-Coord.           Material
       mm         mm       mm                Name
 1       27        -100       -150          A572-50
 2       27        -100       150           A572-50
 3       27        100        -150          A572-50
 4       27        100        150           A572-50
 5       27        -100           0         A572-50
 6       27        100            0         A572-50
ASMTower 2018.4                   Job No.           40m Guyed Pole                              Rev. No.      A
                                  Client            OG                                          Date          5/11/2017
                                  Project           GSM Network                                 Designed by   M.Joe
                                                                                                Checked by    A.S.M
ASMTower 2018.4
Critical Reaction in Global Coordinate System
 #        Support          Load           Fx              Fy       Fz     Horiz.           Mx           My       Mz        Horiz.
                           Com.           KN              KN       KN     Force           KN.m         KN.m     KN.m      Moment
                                                                           KN                                              KN.m
        Guy @15m
 1                            1         50.96           -103.65   13.29   52.66             0           0         0         0
         165Deg
Critical Action in Local Coordinates of Connection
 #        Support          Load           Fx              Fy       Fz     Horiz.           Mx           My       Mz        Horiz.
                           Com.           KN              KN       KN     Force           KN.m         KN.m     KN.m      Moment
                                                                           KN                                              KN.m
        Guy @15m
 1                            1           0.35          103.65    52.66   52.66             0           0         0         0
         165Deg
Force distribution in anchor rods
 #      Diam        Fx             Fy            Fz
        mm          #1             #1            #1
                    KN             KN            KN
 1       27         0.06          17.28          8.78
 2       27         0.06          17.28          8.78
 3       27         0.06          17.28          8.78
 4       27         0.06          17.28          8.78
 5       27         0.06          17.28          8.78
 6       27         0.06          17.28          8.78
Bolt Design
     Anchor rod diameter                                          d         =      27             mm
     Material of anchor rod                                                 =      A572-50
     Gross area of anchor rod                                     Ag        =      572.6          mm2
     Net area of anchor rod                                       An        =      429.4          mm2
     Minimum tensile strength of anchor rod                       Fu        =      448.2          MPa
     Minimum yield strength of anchor rod                         Fy        =      344.7          MPa
     Maximum compression                                          Puc       =      0              KN
     Maximum tension                                              Put       =      17.28          KN
     Considered axial force in interaction 1                      Pu1       =      17.28          KN
     Shear force in interaction 1                                 Vu1       =      8.78           KN
     Nominal tensile strength of anchor rod                       Rnt       =      192.45         KN
ASMTower 2018.4                Job No.      40m Guyed Pole                      Rev. No.            A
                               Client       OG                                  Date                5/11/2017
                               Project      GSM Network                         Designed by         M.Joe
                                                                                Checked by          A.S.M
ASMTower 2018.4
                                                      φ          =   0.8
                                                      η          =   0.55
   Interaction equation                                          =   [ Pu1 + ( Vu1 / η ) ] / φRnt
                                                                 =   0.22
   Bolt status                                                       Safe as 0.22 < 1.0
Check the Pullout Resistance of Anchor
   Type of anchor rod head                                       =   Hex Nut
   Maximum tension in anchor                          T          =   17.28          KN
   Bearing area of anchor head                        Abrg       =   847.9          mm2
   Concrete compressive strength                      F'c        =   21             MPa
   Modification factor for pullout resistance         Ψcp        =   1
   The pullout resistance of anchor                   Np         =   Ψ 8 Abrg F'c
                                                                 =   142.45         KN
   Strength reduction factor                          φ          =   0.7
   Available pullout resistance                       φNp        =   99.71          KN
   Utilization ratio                                  T / φNp    =   0.17
   Saftey satus                                                      Safe as 0.17 < 1.0
Check the Development Length of Anchor
Assumption:
The tension forces are transferred to the longitudinal rebars , which will restrain the concrete failure prism.
Therefore, concrete breakout strength in tension is not checked. The longitudinal reinforcement shall be
developed on either sides of the breakout surface. This development length is calculated to estimate the
minimum embedment length of the anchor.
   The reinforcement bars are deformed bars without
   hook
   Diameter of reinforcement bars                     db         =   16             mm
   Side cover for reinforcement bars                             =   75             mm
   Top cover for reinforcement bars                   Ct         =   50             mm
   Minimum spacing between reinforcement bars                    =   150            mm
   Maximum spacing between reinforcement and
                                                      Sa         =   150            mm
   anchor
   Concrete compressive strength                      F'c        =   21             MPa
ASMTower 2018.4              Job No.         40m Guyed Pole                  Rev. No.       A
                             Client          OG                              Date           5/11/2017
                             Project         GSM Network                     Designed by    M.Joe
                                                                             Checked by     A.S.M
ASMTower 2018.4
   Yielding strength of reinforcement bars             Fy     =   420            MPa
   Lesser of one-half the spacing between anchors and
                                                      cb      =   75             mm
   distance from bar to nearest concrete surface
   Epoxy coated factor                                 Ψe     =   1
   Size factor                                         Ψs     =   0.8
   Casting position factor                             Ψt     =   1
   Light weight concrete factor                        λ      =   1
   Transverse reinforcement index                      ktr    =   0              mm
   Reinforcement bars development length               ldr    =   FyΨt Ψe Ψs /[1.1λ Sqrt(Fc) (cb +Ktr)/db] db
                                                              =   not less 300   mm
                                                              =   426.6          mm
   Length of anchor above top of concrete surface      O      =   75             mm
   Required embeded length for anchor rod              Lan    =   ldr + Ct + Sa / 1.5 + a
                                                              =   626.6          mm
   Required total length for anchor rod                Ltr    =   Lan + O
                                                              =   701.6          mm
   Supplied total length for anchor rod                Lts    =   800            mm
   Utilization ratiofor embeded length                        =   0.86
   Saftey satus                                                   Safe as 0.86 < 1.0
                                              Deformation Chart Of 40m Guyed Pole
                                                       Max Service Wind
               45                                      45                                45
               40                                      40                                40
               30                                      30                                30
Elevation ,m
               20                                      20                                20
               10                                      10                                10
                0                                       0                                 0
                    0   10    20   30   40   50   60        0   0.1   0.2    0.3   0.4        0   0.08 0.16 0.24 0.32 0.4
                             Disp ,mm                            Tilt ,Deg                         Twist ,Deg
                              Global Moment and Shear Chart Of 40m Guyed Pole
                                             Max Design Wind
               45                                      45
               40                                      40
               30                                      30
Elevation ,m
               20                                      20
               10                                      10
                0                                       0
                    0     7        14     21      28        0   3          6          9   12
                        Bending Moment ,KN.m                        Shear Force ,KN
                                Global Moment and Shear Chart Of 40m Guyed Pole
                                    1.2D.L.+1Dg+1.6DesignWL_0Deg_36.11m/s
                    45                                                       45
                    40                                                       40
                    30                                                       30
Elevation ,m
                    20                                                       20
                    10                                                       10
                     0                                                        0
               -9        0        9      18     27   36   -15   -10     -5        0     5   10
                             Bending Moment ,KN.m                     Shear Force ,KN
                                                  LEG GRADE
                                                              DIAGONALS
                                                                                     HEIGHT (m)
            ELEVATION
                                    MAIN LEGS
PANEL NO.
                                                                          DIAGONAL
                        WIDTH (m)
                                                                                     PANELS
                        TOWER
                                                                          GRADE
            (m)
             45 0.25
                                    SP 250x10mm
                                                              ROUND
                                                                           N.A.
                                                                                       N.A.
                                                  A36
 1
             40 0.25
                                                                                                  40m
             40 0.25
                                    SP 250x10mm
                                                              ROUND
                                                                                                        Wir
                                                                           N.A.
                                                                                       N.A.
                                                  A36
 2
                                                                                                            e2
                                                                                                           0 L=
             36 0.25
                                                                                                               42.7
                                                                                                  36m
             36 0.25
                                                                                                                   2m
                                                                                                        W ir
                                                                                                                    IT=
                                                                                                          e1
                                                                                                                        23.
                                                                                                            6L
                                                                                                                            5K
                                    SP 250x10mm
                                                                                                               = 39
                                                                                                                          NB
                                                              ROUND
                                                                           N.A.
                                                                                       N.A.
                                                  A36
                                                                                                                 mI
                                                                                                                             S=2
 3
                                                                                                                    T=1
                                                                                                                                3 5KN
                                                                                                                        5KN
                                                                                                                          BS
                                                                                                                             =15
                                                                                                                                 0KN
             27 0.25
                                                                                                  27m
             27 0.25
                                                                                                         Wi
                                                                                                           re
                                                                                                               8L
                                                                                                                 =3
                                    SP 250x10mm
                                                                                                                   0 .8
                                                              ROUND
                                                                                                                      87
                                                                           N.A.
                                                                                       N.A.
                                                  A36
                                                                                                                        m
                                                                                                                           IT =
                                                                                                                                 3 .7
                                                                                                                                   6K
                                                                                                                                      NB
                                                                                                                                        S=
                                                                                                                                           37
             18 0.25
                                                                                                                                           .6 K
                                                                                                  18m
                                                                                                                                                N
             18 0.25
                                                                                                          W
                                                                                                            ir e
                                                                                                                 8
                                                                                                                   L=
                                                                                                                     23
                                    SP 250x10mm
                                                                                                                          .4
                                                                                                                             3
                                                              ROUND
                                                                                                                                 1m
                                                                           N.A.
                                                                                       N.A.
                                                  A36
 5
                                                                                                                                   IT
                                                                                                                                     =3
                                                                                                                                        .7
                                                                                                                                           6
                                                                                                                                           KN
                                                                                                                                                 BS
                                                                                                                                                      =3
                                                                                                                                                         7  .6
                                                                                                                                                             KN
              9         0.25
                                                                                                  9m
              9         0.25                                                                                   Wi
                                                                                                                 re
                                                                                                                      8L                                                            A      5/11/2017          First issue      M.Joe M.Joe A.S.M
                                                                                                                            =1
                                                                                                                                  7 .4
                                                                                                                                      93                                           REV.      DATE         REVISION/ISSUE        DRN DGN CHD APD
                                                                                                                                           m
                                                                                                                                               IT =
                                                                                                                                                                                                             REVISIONS
                                    SP 250x10mm
                                                                                                                                                      3.7
                                                                                                                                                            6K
                                                                                                                                                              N                     CONFIDENTIALTY :
                                                              ROUND
                                                                                                                                                                  BS
                                                                           N.A.
                                                                                       N.A.
                                                  A36
                                                                                                                                                                                        THESE DRAWINGS AND DESIGNS ARE STRICTLY CONFIDENTIAL AND
 6                                                                                                                                                                   =   37             PROTECTED BY INTERNATIONAL COPYRIGHT LAW.DETAILS MUST NOT BE
                                                                                                                                                                           .6 K         DISCLOSED, REPRODUCED OR COMMUNICATED TO A 3rd PARTY IN ANY
                                                                                                                                                                               N        FORM OR MANNER WITHOUT THE PRIOR WRITTEN PERMISSION OF ASM
                                                                                                                                                                                        FOR ENGINEERING SERIVCES.
                                                                                                                                                                                                                  ASM
              0         0.25                                                                                                                                                        DRAWING TITLE :
                                                                                                                                                                                                        DESIGN DRAWING
                                                                                                                                                                                    JOB NO. : 40m Guyed Pole      PROJECT : GSM Network
                                                                                                                                                                                                DRAWING NO.                       REV.SHEET NO.
                                                                                                                                                                                              ASM-S-GP-25M-01                       A       1 OF 1