0% found this document useful (0 votes)
14 views7 pages

Foot

The document outlines footing design calculations for a project, detailing parameters such as soil bearing capacity, concrete and steel grades, and dimensions of the footing. It includes checks for maximum and minimum soil pressures, bending, shear, and punching shear, ensuring compliance with ACI 318M:2011 standards. The calculations confirm the safety and adequacy of the footing design based on the applied loads and structural requirements.

Uploaded by

renzon272
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views7 pages

Foot

The document outlines footing design calculations for a project, detailing parameters such as soil bearing capacity, concrete and steel grades, and dimensions of the footing. It includes checks for maximum and minimum soil pressures, bending, shear, and punching shear, ensuring compliance with ACI 318M:2011 standards. The calculations confirm the safety and adequacy of the footing design based on the applied loads and structural requirements.

Uploaded by

renzon272
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

FOOTING DESIGN CALCULATIONS

Project Name : sdgsdg


Client Name : dsgfsd
Engineer Name : asdas
Design File : E:\STAAD FILES\GERDY\2.26.24\footing.rcdx
Analysis File : E:\STAAD FILES\GERDY\2.26.24\2.26.24.STD
Analysis Last : 27/02/2024 9:17:02 am
Modified
Definitions:
1. A = Plan area of footing base in sqmm
2. Ast (min) = Area of longitudinal reinforcement as per code
cl. 7.12.2.1 in sqmm
3. Ast Prv = Area of tensile reinforcement provided in sqmm
4. Ast Rqd = Area of longitudinal reinforcement from bearing
moment and minimum % steel provided by user
and as per code cl 7.12.2.1 in sqmm
5. Av = Area of shear reinforcement required in sqmm
6. AvPrv = Area of shear reinforcement provided in sqmm
7. A1 = Bearing area of footing at slope of 1:2 in sqmm
8. A2 = C/s Area of column in sqmm
9. B = Width of footing base in mm
10. Beff = Effective width of footing in mm
11. Boff = Footing offset along B in mm
12. BoffB = Footing offset along B above column in plan
13. BoffT = Footing offset along B below column in plan
14. B1 = Width of sloped footing at top in mm
15. ColOff = Column offset in sloped footing in mm
16. D = Depth of footing in mm
17. d = Effective Depth of footing in mm
18. Dfd = Depth of founding layer in m
19. Dw = Ground water level in m
20. Ec = Modulus of elasticity of concrete in N/sqmm
21. Es = Modulus of elasticity of steel in N/sqmm
22. Foss = Safety factor against sliding
23. Fosu = Safety factor against uplift
24. Fst = Stress in steel in N/sqmm
25. F'c = Characteristic strength of concrete in N/sqmm
26. L = Length of footing base in mm
27. Leff = Effective length of footing in mm
28. Loff = Footing offset along L in mm
29. LoffL = Footing offset along L on left side of column
30. LoffR = Footing offset along L on right side of column
31. L1 = Length of sloped footing at top in mm
32. Mx = Bending Moment along column D in kN-m
33. Mex = Eccentricity moment along column D
34. Mxx = Total Bending Moment along column D (Mx +
Mex)
35. My = Bending Moment along column B in kN-m
36. Mey = Eccentricity moment along column B
37. Myy = Total Bending Moment along column B (My +
Mey)
38. Muy = Factored moment along column B in kN-m
39. Mux = Factored moment along column D in kN-m
40. Netdown = Net downward load in kN
41. OB = Maximum permissible offset on bottom side of
column
42. OL = Maximum permissible offset on left side of
column
43. OR = Maximum permissible offset on right side of
column
44. OT = Maximum permissible offset on top side of
column
45. P = Axial load for footing sizing in kN
46. P1 = Soil pressure at corner 1 in kN/sqm
47. P2 = Soil pressure at corner 2 kN/sqm
48. P3 = Soil pressure at corner 3 kN/sqm
49. P4 = Soil pressure at corner 4 kN/sqm
50. Ntot = Design vertical load on footing in kN
51. q = Surcharge Load in kN/sqm
52. sp = Spacing Between bars at outer most layer in
mm
53. SPu = Upward Soil Pressure in kN/sqm
54. SPuL = Upward Soil Pressure from left
55. SPuR = Upward Soil Pressure from right
56. SPuB = Upward Soil Pressure from bottom
57. SPuT = Upward Soil Pressure from top
58. Temp1 = Peak Hydration temperature in Degree
59. Temp2 = Seasonal Temperature Variations in Degree
60. Vs Capacity = Shear strength capacity of provided shear
reinforcement kN
61. Vu = Design shear force in kN
62. Vus = Strength of shear reinforcement in kN
63. Vx = Shear along major axis in kN
64. Vy = Shear along minor axis in kN
65. Waterpr = Upward water pressure in kN/sqm
66. Waterup = Upward force due to water in kN/sqm
67. WFoot = Add. Wt. due to difference in concrete and soil
density in kN
68. WFootc = Weight of footing and column with concrete
density in kN
69. WSoil = Weight of soil covering footing area in kN
70. Zx = Section modulus of footing base along L in mm 3
71. Zy = Section modulus of footing base along B in mm3
72. Vs = Nominal shear strength provided by shear
reinforcement, in KN
73. Vc = Nominal shear strength provided by concrete in
kN
74. Cx = Width of column in mm
75. Cy = Length of Column in mm
76. Pcr(axial) = Design pressure at the critical section kN/sqm
77. Φ = Strength reduction factor in shear
78. Φ1 = Strength reduction factor in concrete bearing
79. Φ1Pnb = Bearing strength of column in kN

Code References:
ACI 318M:2011
Sr.No
Item Clause / Table
.
1. Ptmax : 10.3.5
2. Ptmin : 7.12.2.1/10.5.4
3. Vc : 11.11.2.1
4. Av : 11.4.7.2
5. Max Stirrup Spacing : 11.4.5.1
6. Vs : 11.4.7.9

Design Code : ACI 318M - 2011

Footing No : FC5

Column No : C5 ( 400mm X 250mm)

Analysis No : 47

Concrete Grade : C20

Steel Grade : Fy275

Clear Cover : 75 mm

Dfd : 1.5 M

Dw : 1M

Density of Soil = 18 KN/cuM

Soil Bearing Capacity = 150 kN/sqm


Permissible SBC Increase for = 33 %
EQ
Permissible SBC Increase for = 33 %
Wind
Live Load Reduction = 0 %

Permissible area of loss of = 0 %


contact

Design cross section by : Average pressure


Consider overburden
pressure

Footing Type : Pad


Footing Size (L x B x D) : 1200mm X 1050mm X 300mm

Effective Self Weight = 9.45 KN

Offset Along L (Loff) = 400 mm

Offset Along B (Boff) = 400 mm

Check For Maximum Soil Pressure:

Critical Load Combination = [2] : (LOAD 3: DL) +(LOAD 4: LL)

Pcomb = 171.79 kN
P
= Pcomb + Effective Self Weight
P = 181.24 kN
Mx = 0 kNm
My = 0 kNm
P/A = 143.84 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 143.84 kN/sqm
Allowable Soil Pressure = 1x150 kN/sqm
= 150 kN/sqm

Check For Minimum Soil Pressure:


Critical Load Combination = [10] : 0.6 (LOAD 3:
DL) +0.6 (LOAD 1: EX)
Pcomb = 86.08 kN
P = Pcomb + Effective Self Weight x 0.6
P = 91.75 kN
Mx = 0 kNm
My = 0 kNm
P/A = 72.82 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 72.82 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Load Combination = [15] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 171.17 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 217 mm
Beff = 1050 mm
SPu = 171.17 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 14.38 kNm
Ast Rqd = 866 sqmm
Ast (min) = 866 sqmm
Ast Prv = 7 - #13 @ 175
= 887 sqmm
Distributed Across Total Width

Bottom Reinforcement Along B:


Critical Load Combination = [15] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 171.17 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 201 mm
Leff = 1200 mm
SPu = 171.17 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 16.43 kNm
Ast Rqd = 990 sqmm
Ast (min) = 990 sqmm
Ast Prv = 8 - #13 @ 175
= 1013 sqmm
Distributed Across Total Length

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 217 mm
Critical Load Combination = [15] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 171.17 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 217 mm
Beff = 1050 mm
SPu = 171.17 kN/sqm
Vu = SPu X (Loff - d) X B
= 32.89 kN
φVc = 134.54 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 201 mm
Critical Load Combination = [15] : 1.2 (LOAD 3:
DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 171.17 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 201 mm
Leff = 1200 mm
SPu = 171.17 kN/sqm
Vu = SPu X (Boff - d) X L
= 40.87 kN
φVc = 124.62 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 104 mm

Critical Load Combination = [15] : 1.2 (LOAD 3: DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 171.17 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 209 mm
Leff = 609 mm
Beff = 459 mm
SPu = Average Pressure
= 171.17 kN/sqm
Vu = { N - Pcr(axial)[ (Cx +
d) X (Cy + d)]}
= 167.82 kN
φVn = 748.676 kN
φVc = 494.126 kN
No Shear
Vu < φVc Reinforcement
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Load Combination = [15] : 1.2 (LOAD 3:
DL) +1.6 (LOAD 4: LL)
Pu = 215.67 kN
A2 = 0.1 sqm
A1 = 2.32 sqm
Base Area = 1.26 sqm
A1 > Base Area
Thus, A1 = 1.26
Modification Factor = SquareRoot(A1/A2) <
=2
SquareRoot(A1/A2) = 3.5496
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X
Column Area
= 2210 kN
Φ1Pnb > Pu, Hence Safe.