0760P Global P3Y
0760P Global P3Y
CATALOG 0760P
Filters, Regulators, Lubricators,& Airline Accessories.
Warning, Offer of Sale
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product
and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of
your application including consequences of any failure, and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its
own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all
performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are
subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized
distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled
“Offer of Sale”.
© Copyright 2020, 2018, 2016 Parker Hannifin Corporation. All Rights Reserved
Introduction 2-9
P3Y Series
P3Y System 81
Particulate Filters 82 - 83
Coalescing Filters 84 - 85
Regulators 86 - 89
Proportional Pressure Regulators 90 - 91
Filter / Regulators 92 - 93
Lubricators 94 - 95
Combinations 96 - 97
Soft Start / Dump Valves 98 - 101
Accessories 102 - 105
COMPLIANT
DECLARATION OF COMPLIANCE (ROHS) ATEX
European Directive 2011/65/EU – RoHS (Restriction us of certain Following Ignition Hazard Assessments performed on the non-
Hazardous Substances in electrical and electronic equipment), electrical Global Air Preparation products they are in accordance
restricts the use of the 6 substances in the manufacture of specified with the requirements of EN 13463-1:2009, it was considered that the
electrical equipment. equipment does not contain its own source of ignition, and therefore
Lead: Product containing lead and its compound (except for is not within the scope of directive 94/9/EC.
applications of lead as an alloying element by weight in The products can be used in a Group II Category 2 environment
steel up to 0.35%, in aluminium up to 0.4% and in copper assuming that the ATEX Directive and the following conditions are
alloys up to 4% and in circuit board solder) must not complied with:
exceed 0.1% by weight • Installation and maintenance of the product must be undertaken
Mercury: The concentration level must not exceed 0.1% by volume by qualified personnel.
Cadmium: The concentration level must not exceed 0.01% by • Do not mount the products in an area where impact may occur.
volume • Filters must be used to limit the introduction of particles and to
Hexavalent Chromiou: capture particles generated in service.
This is a corrosive protective finish used on our product • Supply air quality must be within ISO 8573-1:2010 Class 1.4.2.
line. Where this finish is utilized the Chromate solution • Maximum working temperature to be as stated on product label.
is Hexavalent (Chrome 6) free. • WARNING – pulsating pressure and/or a closed circuit can
Polybrominated Biphenyls (PBB): generate heat.
The concentration level must not exceed 0.1% by weight. • Deposits of dust on the product must not exceed
This substance is not know to be in any of our products. 5mm thickness.
Polybrominated Diphenyl Esters (PBDE): Refer to technical file for surface areas of plastics. The unit
The concentration level must not exceed 0.1% by must be earthed via the compressed air supply line.
weight. This substance is not know to be in any of our • The unit must not come into contact with liquid solvents, acids or
products. alkalis
Refer to technical file for chemicals known to be
incompatible. Product cleaning must be undertaken using
a method complying with the specifications of the ATEX
zone, preferably by using mild soap and water or antistatic
products.
• Regulators, Filter Regulators:
Global Air Preparation products supplied by Parker Hannifin have Do not use Regulators or Filter Regulators within systems
been designed and manufactured in accordance with “sound that can create vibration within the Regulator / Filter
engineering practice”, as defined by Article 3 of Pressure Equipment Regulator unit.
Directive 97/23/EC. • Solenoid Operated Valves:
Are suitable for use in an ATEX environment, (Group II
Category 2) providing ATEX approved solenoids are fitted.
• Technical file available on request.
Global Air Preparation product range has been designed and tested in
accordance with ISO flow testing, envelope integrity, and catalog data
Global Air Preparation product range has been third party Shock presented.
& Vibration tested independently in accordance to EN 61373 : 1999, • Filters – ISO 5782-1 & ISO 5782-2: 1997
Category 2 • Regulators- ISO 6953-1 & ISO 6953-2: 2000
• Lubricators- ISO 6301-1 & ISO 6301-2: 2009
Global.
Modular.
Performance you need,
wherever you need it.
www.parker.com
P3Y Series
3/4" and 1"
90mm body width
Air Preparation
P31 Mini Series P32 Compact Series
Stage 1 2
3
As air is compressed
For every 11°C (20°F)
to 7 bar (100 psig)
that the air cools after
and higher, the relative
leaving the heat of the
humidity quickly reaches
compressor, 50% of the
4
100% RH and air
moisture condenses into Bulk liquid separators
temperatures can reach
liquid into the system. remove condensed
between
110°C and 200°C (230°F liquids after the
5
and 392°F). aftercooler, receiver,
The excess moisture or anywhere within the Particulate filters are
condenses and collects distribution system. used for the removal
in the receiver tank and of solid particle
distribution lines. This Bulk liquid separators contaminants down to 5
condensate must be also help protect micron, as well as Coalescing filters are
removed. downstream filters in the the removal of designed to remove
system where excess condensed liquids water and oil aerosols
cooling takes place. (not vapor) and
Note: Water and oil, particulate from air
in vapor form, pass streams down to 0.01
through general purpose micron in size.
particulate filters.
Installed in pairs,
Particulate and
This type of filter should Coalescing filters ensure
be used as a prefilter for a continuous supply of
Key the coalescing (oil high quality air.
removal) filter.
Particulate
Oil
Water
Oil Vapor
Water Vapor
Stages 1 2 3 4 5 6 7
Bulk Liquid Particulate Coalescing Hydrocarbon
Function Air Compressor Air Dryers
Removal Filtration Filtration Removal
All pneumatic Basic pneumatic Basic pneumatic Systems requiring Systems requiring Systems requiring
Application systems systems systems highest quality air. air with reduced highest quality air for
moisture content critical applications
Air leaving the Removes bulk Removes solid Removes liquid Removes water Removal of odors
compressor room at liquid contamination particulates down to 5 aerosols and vapor from air and trace vapors for
93ºC (200ºF) releases and protects filters micron, and submicron stream. Dew point critical applications.
Description 95% of its moisture where excess cooling the separation of bulk particulates (not reduced down to 4ºC
into the piping system takes place in the contaminants. vapor) down to (40ºF) (refrigeration)
when it cools to 38ºC distribution piping 0.01 micron. or -40ºC (-40ºF)
(100ºF) (desiccant).
Parker Customer P3TF P31, P32, P33, P3Y P31, P32, P33, P3Y Refrigeration Dryer, P31, P32, P33, P3Y
Global Air supplied Bulk Liquid Particulate Filter Coalescing Filter TW Regenerative Activated Carbon
Separator Desiccant Dryer (Adsorber) Filter
Preparation
Solution
Clean
Dry Air
6
Refrigeration and
desiccant dryers lower
the air’s dew point by
removing water vapor,
providing appropriately
dry air for the
7
Hydrocarbon and oil
vapors are removed
downstream application. using filters utilizing
activated carbon.
Airborne hydrocarbons
are often left over from
the compressor oils.
A completely modular
air preparation system
Soft Start /
Easy to adjust non-rising Dump Valve
knob with snap-lock,
preventing accidental
change of set pressure
2-piece Patented
modular body
connector US Patent
number 5,383,689
Filter / Regulator
Pressure
gauge
Ball Valve
Aluminum
body
NPT, BSPP or
BSPT porting
available
Coalescing
Filter
Padlock
Bowl guard
slide
with multiple
Quick release
viewing slots
bayonet-type
integral bowl
and bowl guard
assembly
Manual drain with
pipe-away, auto
drain available
1 2 1 2
Operating Information
Manual drain Pulse drain
Supply pressure (max):
Plastic bowl 150 psig (10 bar)
Metal bowl 250 psig (17 bar)
Operating temperature:
Plastic bowl 14°F to 125°F (-10°C to 52°C)
Metal bowl 14°F to 150°F (-10°C to 65.5°C)
Port
Size Description ‡ Part Number Standard filtration: 5 micron
1/4" Poly Bowl, Manual Drain P31FB92EGMN Flow capacity*: 25 scfm (12 dm3/s, ANR)
Useful retention : †
0.4 US oz. (12 cm3)
1/4" Poly Bowl, Pulse Drain P31FB92EGBN
Weight: 0.24 lb (0.11 kg)
1/4" Metal Bowl, Manual Drain P31FB92EMMN
* Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
1/4" Metal Bowl, Pulse Drain P31FB92EMBN †
Useful retention refers to volume below the quiet zone baffle.
‡
For polycarbonate bowl, see caution in Engineering Section A. Air quality:
Within ISO 8573-1: 1991 Class 3 (Particulates)
Within ISO 8573-1: 2001 Class 6 (Particulates)
Ordering Information:
P31FB 9 2 E G M N
Basic Series Thread Type Mounting
Global Modular Mini BSPP 1 N No Bracket
P31FB
Particulate Filter BSPT 2
Drain Type
NPT 9
M Manual Drain
Port Size B Pulse Drain
1/4 2
Bowl Type
Element G Poly Bowl with Bowl Guard
5µ Element E Metal Bowl without Sight
M
Gauge
Most popular.
0 0
Repair and Service Kits 0 5 10 15
Flow - (dm 3/s)
20 25 30
n
Plastic bowl / bowl guard, manual drain P31KB00BGM 0 10 20 30 40 50 60
Flow - (scfm)
Metal bowl / w/o sight gauge, manual drain P31KB00BMM
Plastic bowl / bowl guard, pulse drain P31KB00BGB
Metal bowl / w/o sight gauge, pulse drain P31KB00BMB
5µ particle filter element P31KA00ESE
C-bracket (fits to body) P31KA00MW
T-bracket with body connector P31KA00MT
Body connector P31KA00CB
1.58
(40)
1.58 .79
(40) (20)
.84
(21.4)
4.91 4.71
(124.8) (119.6)
5/32 (4mm)
I.D. tube Bowl
barb fitting 1.30 removal
(33) clearance
Inches (mm)
1 2 1 2
Port
Size Description ‡ Part Number Operating Information
1/4" Poly Bowl, Manual Drain P32FB92EGMN Supply pressure (max):
1/4" Poly Bowl, Auto Drain P32FB92EGAN Plastic bowl 150 psig (10 bar)
Metal bowl 250 psig (17 bar)
1/4" Metal Bowl, Manual Drain P32FB92ESMN Operating temperature:
1/4" Metal Bowl, Auto Drain P32FB92ESAN Plastic bowl -13°F to 125°F (-25°C to 52°C)
Metal bowl -13°F to 150°F (-25°C to 65.5°C)
3/8" Poly Bowl, Manual Drain P32FB93EGMN
Standard filtration: 5 micron
3/8" Poly Bowl, Auto Drain P32FB93EGAN Flow capacity*: 1/4 50 scfm (24 dm3/s, ANR)
3/8" Metal Bowl, Manual Drain P32FB93ESMN 3/8 78 scfm (37 dm3/s, ANR)
1/2 82 scfm (39 dm3/s, ANR)
3/8" Metal Bowl, Auto Drain P32FB93ESAN
Useful retention†: 1.7 US oz. (51 cm3)
1/2" Poly Bowl, Manual Drain P32FB94EGMN Weight: 0.62 lb (0.28 kg)
1/2" Poly Bowl, Auto Drain P32FB94EGAN * Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
†
Useful retention refers to volume below the quiet zone baffle.
1/2" Metal Bowl, Manual Drain P32FB94ESMN
Air quality:
1/2" Metal Bowl, Auto Drain P32FB94ESAN Within ISO 8573-1: 1991 Class 3 (Particulates)
Within ISO 8573-1: 2001 Class 6 (Particulates)
‡
For polycarbonate bowl, see caution in Engineering Section A.
Ordering Information:
P32FB 9 2 E G M N
Basic Series Thread Type Mounting
Global Modular Compact BSPP 1 N No Bracket
P32FB
Particulate Filter BSPT 2
Drain Type
NPT 9
M Manual Drain
Port Size A Auto Drain
1/4 2
3/8 3
Bowl Type
1/2 4 G Poly Bowl with Bowl Guard
Metal Bowl without Sight
Element M
Gauge
5µ Element E S Metal Bowl with Sight Gauge
Most popular.
0 20 40 60 80
Flow - (scfm)
Repair and Service Kits
Plastic bowl / bowl guard, manual drain P32KB00BGM P32FB 3/8" Filter
Primary Pressure - bar 2.5 6.3 10
Metal bowl / sight gauge, manual drain P32KB00BSM Primary Pressure - psig 36.2 91.4 145
0.5
Auto drain P32KA00DA 7
0 0
0 10 20 30 40 50 60 70
Flow - (dm 3/s)
n
6 0.4
Pressure Drop - (psig)
5
0.3
4
3 0.2
2
7.49 7.26 0.1
(190.3) (184.3) 1
0 0
0 10 20 30 40 50 60 70 80
Flow - (dm 3/s)
n
.18 (4.8mm)
I.D. tube
barb fitting
2.28 Bowl
(58) removal
clearance
Inches (mm)
1 2 1 2
Operating Information
Supply pressure (max):
Port Plastic bowl 150 psig (10 bar)
Size Description ‡
Part Number Metal bowl 250 psig (17 bar)
1/2" Poly Bowl, Manual Drain P33FA94EGMN Operating temperature:
Plastic bowl -13°F to 125°F (-25°C to 52°C)
1/2" Poly Bowl, Auto Drain P33FA94EGAN
Metal bowl -13°F to 150°F (-25°C to 65.5°C)
1/2" Metal Bowl, Manual Drain P33FA94ESMN Standard filtration: 5 micron
1/2" Metal Bowl, Auto Drain P33FA94ESAN Flow capacity*: 1/2 85 scfm (40 dm3/s, ANR)
3/4 102 scfm (48 dm3/s, ANR)
3/4" Poly Bowl, Manual Drain P33FA96EGMN
Useful retention†: 2.8 US oz. (85 cm3)
3/4" Poly Bowl, Auto Drain P33FA96EGAN
Weight: 1.01 lb (0.46 kg)
3/4" Metal Bowl, Manual Drain P33FA96ESMN * Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
†
Useful retention refers to volume below the quiet zone baffle.
3/4" Metal Bowl, Auto Drain P33FA96ESAN
‡
For polycarbonate bowl, see caution in Engineering Section A. Air quality:
Within ISO 8573-1: 1991 Class 3 (Particulates)
Within ISO 8573-1: 2001 Class 6 (Particulates)
Ordering Information:
P33FA 9 6 E G M N
Basic Series Thread Type Mounting
Global Modular Standard BSPP 1 N No Bracket
P33FA
Particulate Filter BSPT 2
Drain Type
NPT 9
M Manual Drain
Port Size A Auto Drain
1/2 4
3/4 6
Bowl Type
G Poly Bowl with Bowl Guard
Element Metal Bowl without Sight
M
5µ Element E Gauge
S Metal Bowl with Sight Gauge
Most popular.
Seals Nitrile 0 0
0 10 20 30 40 50 60 70
Sight gauge Nylon Flow - (dm 3/s)
n
3
T-bracket (fits to body connector) P32KA00MB 0.2
2
T-bracket with body connector P33KA00MT 0.1
1
Body connector P32KA00CB 0 0
0 10 20 30 40 50 60 70 80
Flow - (dm 3/s)
n
2.87
(73)
2.87 1.42
(73) (36)
1.02
(26)
8.39 8.15
(213) (207)
.18 (4.8mm)
I.D. tube Use 3/8" or
barb fitting (10mm) Flex
2.00 Bowl Tubing
(51) removal
clearance
Inches (mm)
Ordering Information:
P31FB 9 2 C G M N
Basic Series Thread Type Mounting
Global Modular Mini BSPP 1 N No Bracket
P31FB
Coalescing Filter BSPT 2
Drain Type
NPT 9
B Pulse Drain
Port Size M Manual Drain
1/4 2
Bowl Type
Element G Poly Bowl with Bowl Guard
0.01µ Element C Metal Bowl without Sight
1µ Element 9 M
Gauge
Adsorber A
Most popular.
0 5 10
Flow - (scfm)
1.58
(40)
1.58 .79
(40) (20)
.84
(21.4)
4.91 4.71
(124.8) (119.6)
5/32 (4mm)
I.D. tube Bowl
barb fitting 1.30 removal
(33) clearance
Inches (mm)
Ordering Information:
P32FB 9 2 D G M N
Basic Series Thread Type Mounting
Global Modular Compact BSPP 1 N No Bracket
P32FB
Coalescing Filter BSPT 2
Drain Type
NPT 9
M Manual Drain
Port Size A Auto Drain
1/4 2
3/8 3 Bowl Type
1/2 4 G Poly Bowl with Bowl Guard
Metal Bowl without Sight
Element M
Gauge
0.01µ Element C
S Metal Bowl with Sight Gauge
0.01µ Element with DPI D
1µ Element 9
1µ Element with DPI Q
Adsorber A
Most popular.
0 0
Repair and Service Kits 0 10 20 30 40
Flow - (dm 3/s)
50 60 70
n
Plastic bowl / bowl guard, manual drain P32KB00BGM 0 20 40 60 80 100 120 140
Flow - (scfm)
Metal bowl / sight gauge, manual drain P32KB00BSM
Auto drain P32KA00DA
1µ coalescing filter element P32KA00ES9 P32FB - 0.01 micron flow
0.01µ coalescing filter element P32KA00ESC Primary Pressure - bar 6.3 10
Primary Pressure - psig 91.4 145
Activated carbon adsorber filter element P32KA00ESA 7 0.5 2.5
36.3
L-bracket (fits to body) P32KA00ML 6 0.4
3 0.2
Body connector P32KA00CB
2 Saturated
Differential pressure indicator (replacement) P32KA00RQ 0.1 Element
1 Flow
0 0
0 10 20 30 40 50
Flow - (dm 3/s)
n
0 20 40 60 80 100
Flow - (scfm)
2.36
(60)
2.36 1.18
(60) (30)
1.90
(48.3)
8.36 8.12
(212.3) (206.3)
.18 (4.8mm)
I.D. tube
barb fitting Bowl
2.28 removal
(58) clearance
Inches (mm)
Ordering Information:
P33FA 9 6 D G M N
Basic Series Thread Type Mounting
Global Modular Standard BSPP 1 N No Bracket
P33FA
Coalescing Filter BSPT 2
Drain Type
NPT 9
M Manual Drain
Port Size A Auto Drain
1/2 4
Bowl Type
3/4 6
G Poly Bowl with Bowl Guard
Element Metal Bowl without Sight
M
0.01µ Element C Gauge
0.01µ Element with DPI D S Metal Bowl with Sight Gauge
1µ Element 9
1µ Element with DPI Q
Adsorber A
Most popular.
0 20 40 60 80 100
Metal bowl / sight gauge, manual drain P33KA00BSM Flow - (scfm)
1.02
(26)
9.25 9.02
(235) (229)
.18 (4.8mm)
I.D. tube Use 3/8" or
barb fitting 10mm Flex
Bowl
2.00 Tubing
removal
(51) clearance
Inches (mm)
3
Operating Information
1 2
1 2 Flow capacity*: 1/4 73 scfm (34 dm3/s, ANR)
Operating temperature : †
-4°F to 150°F (-20°C to 65.5°C)
Self relieving regulator Non-relieving regulator Supply pressure (max): 300 psig (20 bar)
with gauge Adjusting range pressure: 30 psig (0-2 bar)
60 psig (0-4 bar)
125 psig (0-8 bar)
232 psig (0-16 bar)
Weight: 0.37 lb (0.17 kg)
Port Description * Inlet pressure 145 psig (10 bar). Secondary pressure 100 psig (6.9 bar)
Size (relieving) Gauge Part Number and 14.5 psig (1 bar) pressure drop.
† Units with square gauges: 5°F to 150°F (-15°C to 65.5°C)
1/4" 125 psig (8 bar) Square P31RB92BN5P
Gauge supplied with every part. Gauge can be installed on the front or back
of the regulator. If no gauge is installed, both seal screws must be installed.
Ordering Information:
P31RB 9 2 B N 5 P
Mounting
Basic Series Thread Type P Plastic Panel Mount Nut
Global Modular BSPP 1
P31RB
Mini Regulator BSPT 2 Adjustment Range
NPT 9 With Square Gauge
Port Size psig bar MPa
1/4 2 1 = 30* V = 2* 2 = 0.2*
3 = 60 S=4 4 = 0.4
Relief
5 = 125 T=8 6 = 0.8
Relieving B
7 = 232 W = 16 8 = 1.6
Non-Relieving N
* Regulator comes with gauge respective to the
Reverse Flow - Relieving R adjustment range available.
Adjustment
N Non-rising Knob
Most popular.
P1
P2 P2 P2 P2
3 1 2 Operating Information
1 2
Flow capacity*:
1/4 64 scfm (31 dm3/s, ANR)
Self relieving regulator Non-relieving regulator Operating temperature: -4°F to 150°F (-20°C to 65.5°C)
with gauge
Supply pressure (max): 300 psig (20 bar)
Adjusting range pressure: 30 psig (0-2 bar)
60 psig (0-4 bar)
125 psig (0-8 bar)
Port Description 232 psig (0-16 bar)
Size (relieving) Gauge Part Number P1 port size (inlet/outlet) 1/4 NPT, BSPP, BSPT
1/4" 125 psig (8 bar) Square P31HB92BN5P P2 regulated ports (2 ea.) 1/8 NPT, BSPP, BSPT
Weight: 0.66 lb (0.30 kg)
* Inlet pressure 145 psig (10 bar). Secondary pressure 100 psig (6.9 bar) and
14.5 psig (1 bar) pressure drop.
Gauge supplied with every part. Gauge can be installed on the front or back
of the regulator. If no gauge is installed, both seal screws must be installed.
Ordering Information:
P31HB 9 2 B N 5 P
Basic Series Thread Type Mounting
Global Modular Mini BSPP 1 P Plastic Panel Mount Nut
P31HB
Common Regulator BSPT 2
NPT 9 Adjustment Range
Port Size † With Square Gauge
1/4 2 psig Bar MPa
† Working port 1/8" 1 = 30* V = 2* 2 = 0.2*
3 = 60 S=4 4 = 0.4
Relief
5 = 125 T=8 6 = 0.8
Relieving B
7 = 232 W = 16 8 = 1.6
Non-Relieving N
* Regulator comes with gauge respective
Reverse Flow - Relieving R to the adjustment range available.
Adjustment
N Non-Rising Knob
Most popular.
WARNING
40mm Round 0-30 psig / 0-2 bar K4515N18030
Product rupture can cause serious injury. 1/8” center back 0-60 psig / 0-4 bar K4515N18060
Do not connect regulator to bottled gas.
mount (not for use 0-160 psig / 0-11bar K4515N18160
Do not exceed Maximum primary pressure rating.
with common port
regulators)
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range. For best performance, regulated pressure should always be set by increasing
Pressure adjustment beyond this range is also possible because the knob the pressure up to the desired setting.
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
*For P31 Regulators with date code after November 2023 (4423 Date Code),
please use these part numbers when ordering a replacement gauge.
3 1 2
1 2
1/4" 125 psig (8 bar) None P32RB92BNNP Adjusting range pressure: 30 psig (0-2 bar)
60 psig (0-4 bar)
1/4" 125 psig (8 bar) Round P32RB92BNGP 125 psig (0-8 bar)
250 psig (0-17 bar)
3/8" 125 psig (8 bar) None P32RB93BNNP
Gauge port (2 each) 1/4 NPT, BSPP, BSPT
3/8" 125 psig (8 bar) Round P32RB93BNGP
Weight: 1.24 lb (0.56 kg)
1/2" 125 psig (8 bar) None P32RB94BNNP * Inlet pressure 145 psig (10 bar). Secondary pressure 80.0 psig (5.5 bar)
1/2" 125 psig (8 bar) Round P32RB94BNGP
Ordering Information:
P32RB 9 2 B N G P
Basic Series Thread Type Mounting
Global Modular BSPP 1 P Plastic Panel Mount Nut
P32RB
Compact Regulator BSPT 2 Adjustment Range
NPT 9 With Round Gauge
Port Size Z 30 psig; 2 bar; 0.2 MPa
1/4 2 M 60 psig; 4 bar; 0.4 MPa
3/8 3 G 125 psig; 8 bar; 0.8 MPa
1/2 4 J 250 psig; 17 bar; 1.7 MPa
Without Gauge
Relief
Y 30 psig; 2 bar; 0.2 MPa
Relieving B
L 60 psig; 4 bar; 0.4 MPa
Non-Relieving N
N 125 psig; 8 bar; 0.8 MPa
Adjustment H 250 psig; 17 bar; 1.7 MPa
Non-Rising * Regulator comes with gauge
N
Knob respective to the adjustment range
selected.
Most popular.
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas. P32RB 1/2" Regulator
Do not exceed Maximum primary pressure rating.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
Gauges
Square with 0-4 bar P6G-PR10040
adapter kit
0-11 bar P6G-PR10110
0-60 psig P6G-PR90060
0-160 psig P6G-PR90160
50mm (2") round 0-30 psig / 0-2 bar K4520N14030
1/4" center back
0-60 psig / 0-4 bar K4520N14060
mount
0-160 psig / 0-11 bar K4520N14160
0-300 psig / 0-20 bar K4520N14300
For best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
P1
P2 P2 P2 P2
3 1 2
1 2 Operating Information
Flow capacity*:
Self relieving regulator Non-relieving regulator 1/4, 3/8, 1/2 94 scfm (44 dm3/s, ANR)
with gauge Operating temperature: -25°C to 65.5°C (-13°F to 150°F)
Supply pressure (max): 300 psig (20 bar)
Adjusting range pressure: 0 to 30 psig (0 to 2 bar)
0 to 60 psig (0 to 4 bar)
Port Description 0 to 125 psig (0 to 8 bar)
Size (relieving) Gauge Part Number 0 to 232 psig (0 to 16 bar)
1/4" 125 psig (8 bar) None P32HB92BNNP Gauge port (2 each): 1/4 NPT, BSPP, BSPT
3/8" 125 psig (8 bar) None P32HB93BNNP Weight: 1.21 lb (0.55 kg)
* Inlet pressure 145 psig (10 bar). Secondary pressure 80.0 psig (5.5 bar)
1/2" 125 psig (8 bar) None P32HB94BNNP and 14.5 psig (1 bar) pressure drop.
Ordering Information:
P32HB 9 2 B N N P
Basic Series Thread Type Mounting
Global Modular BSPP 1 P Plastic Panel Mount Nut
P32HB
Compact Regulator BSPT 2
Adjustment Range
NPT 9
With Round Gauge
Port Size † Z 30 psig; 2 bar; 0.2 MPa
1/4 2 M 60 psig; 4 bar; 0.4 MPa
3/8 3 G 125 psig; 8 bar; 0.8 MPa
1/2 4 J 250 psig; 17 bar; 1.7 MPa
† Working port 1/4". Without Gauge
Relief Y 30 psig; 2 bar; 0.2 MPa
Relieving B L 60 psig; 4 bar; 0.4 MPa
Non-Relieving N N 125 psig; 8 bar; 0.8 MPa
Adjustment H 250 psig; 17 bar; 1.7 MPa
* Regulator comes with gauge respective to the
N Non-Rising Knob
adjustment range selected.
Most popular.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
Gauges
Square with 0-4 bar P6G-PR10040
adapter kit
0-11 bar P6G-PR10110
0-60 psig P6G-PR90060
0-160 psig P6G-PR90160
50mm (2") round 0-30 psig / 0-2 bar K4520N14030
1/4" center back
0-60 psig / 0-4 bar K4520N14060
mount
0-160 psig / 0-11 bar K4520N14160
0-300 psig / 0-20 bar K4520N14300
For best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
3 1 2
1 2
Operating Information
Self relieving regulator Non-relieving regulator Flow capacity*:
with gauge 1/2, 3/4 233 scfm (110 dm3/s, ANR)
Operating temperature: -13°F to 150°F (-25°C to 65.5°C)
Supply pressure (max): 300 psig (20 bar)
Adjusting range pressure: 0 to 30 psig (0 to 2 bar)
Port Description 0 to 60 psig (0 to 4 bar)
Size (relieving) Gauge Part Number 0 to 125 psig (0 to 8 bar)
0 to 250 psig (0 to 17 bar)
1/2" 125 psig (8 bar) None P33RA94BNNP
Gauge port (2 each): 1/4 NPT, BSPP, BSPT
1/2" 125 psig (8 bar) Round P33RA94BNGP
Weight: 1.37 lb (0.62 kg)
3/4" 125 psig (8 bar) None P33RA96BNNP * Inlet pressure 145 psig (10 bar). Secondary pressure 91.3 psig (6.3 bar)
3/4" 125 psig (8 bar) Round P33RA96BNGP and 14.5 psig (1 bar) pressure drop.
Ordering Information:
P33RA 9 6 B N G P
Basic Series Thread Type Mounting
Global Modular BSPP 1 P Plastic Panel Mount Nut
P33RA
Standard Regulator BSPT 2
NPT 9 Adjustment Range
With Round Gauge
Port Size
Z 30 psig; 2 bar; 0.2 MPa
1/2 4
M 60 psig; 4 bar; 0.4 MPa
3/4 6
G 125 psig; 8 bar; 0.8 MPa
Relief J 250 psig; 17 bar; 1.7 MPa
Relieving B Without Gauge
Non-Relieving N Y 30 psig; 2 bar; 0.2 MPa
Reverse Flow- R L 60 psig; 4 bar; 0.4 MPa
Relieving N 125 psig; 8 bar; 0.8 MPa
H 250 psig; 17 bar; 1.7 MPa
Adjustment
Non-Rising Knob N
Most popular.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
4.27 Round
(108) Gauge
2.87
Gauges
(73) 50mm (2") round 0-30 psig / 0-2 bar K4520N14030
2.87 1.44
(73) (37) 1/4" center back
0-60 psig / 0-4 bar K4520N14060
mount
0-160 psig / 0-11 bar K4520N14160
44
(1.73) 0-300 psig / 0-20 bar K4520N14300
3.30 For best performance, regulated pressure should always be set by increasing the
(83.8)
pressure up to the desired setting.
5.87
(149)
Inches (mm)
Operating Information
Flow capacity*: P31P 40 scfm (19 dm3/s, ANR)
P32P 120 scfm (57 dm3/s, ANR)
Temperature range: 32°F to 122°F (0°C to 50°C)
Supply pressure (max):
2 bar unit 36.3 psig (2.5 bar)
10 bar unit 152 psig (10.5 bar)
Operating pressure (min): P2 pressure + 7.3 psig (0.5 bar)
Working medium: Compressed air or inert gasses,
filtered to 40µ
Pressure range: 0 to 30 psig (0 to 2 bar)
Port 0 to 145 psig (0 to 10 bar)
Size Description Part Number
Weight: P31P 0.64 lb (0.291 kg)
1/4" 145 psig (0-10 bar), NC 0-10V P31PA92AD2VD1A P32P 1.42 lb (0.645 kg)
* Inlet pressure 91.3 psig (6.3 bar), inlet pressure and 4.9 psig (0.34 bar) pressure
1/2" 145 psig (0-10 bar), NC 0-10V P32PA94AD2VD1A drop.
Ordering Information:
P31PA 9 2 A D 2 V D 1 A
Body Size Thread Type Power Control Signal Input Connector
Global Modular Mini (1/4") P31PA BSPP 1 Supply V 0-10V ‡ 1 M12 (4-pin)
Global Modular Compact BSPT 2 2 24 volts ‡ Factory setting is
P32PA Output Signal
(1/2") NPT 9 0-10 V control signal.
Pressure Range 4-20 mA control D Digital, PNP
Port Size Z 0 - 29 psig (0 - 2 bar) signal available
via parameter 4 on P PNP or 0-10V
Global Modular Mini (1/4") 2 D 0 - 145 psig (0 - 10 bar)
keypad. N NPN or 0-10V
Global Modular Compact (1/2") 4 M 4-20mA Fixed
D) Digital PNP output only, no analog
Version
output selectable
Bottom Ported Exhaust (NC) A P) Digital PNP and analogue 0-10V
outputs selectable, by means of
Bottom Ported Forced Exhaust (NO) † E
parameter 6. (Factory default 0-10V)
† When the supply voltage is lost the unit will N) Digital NPN and analog 0-10 V outputs
automatically exhaust the regulated pressure selectable by means of parameter 6.
to 0 bar (atmospheric pressure) Factory default 0-10V)
M) Analog 4-20mA output only.
Note: On all analog outputs the F.S.
value can be adjusted by means of
parameter 8.
Most popular.
Display 0 0
0 5 10 15 20 25 30 35
Flow - (dm 3/s)
The regulator is provided with a digital display, indicating the n
Connections
(In case of output signal (Option D) Mounting position
Central M12 connector 4-pole Preferably vertical, with the cable gland on top.
The electrical connections are as follows:
Materials: P31P & P32P
Magnet core Steel
Pin No. Function Color Solenoid valve poppet FPM
1 24 V Supply Brown Solenoid valve housing Techno polymer
0 to 10 V Control Signal Ri = 100k W Regulator body (P31P & P32P versions) Aluminum
2 White
4 to 20mA Control Signal Ri = 500 W Regulator top housing Nylon
3 0 V (GND) Supply & Set Point Ground Blue Valve head Brass & NBR
4 24 V Alarm Output Signal Black Remaining seals NBR
3-6 seconds
Until Display
Reads
3-6 seconds
Until Display
Reads
3-6 seconds
Until Display
Reads
Flashing Decimal
Flashing Decimal (Value 0, 1 or 2) Flashing
Displays current
parameter value. Edits parameter.
Description 1 = m factory 0 = digital
Accesses default for P3H (NPN or PNP) Accepts and saves
changeable Accesses with analog 1 = analog 0..10V new parameter Sequences to next
parameters. parameter no. 6. options 2 = analog 4..20 mA setting. parameter.
3-6 seconds
Until Display
Reads
Flashing Decimal Flashing Decimal
(For 2 bar versions (Value between
value = 92) 0 and 130) Flashing
or or
3-6 seconds
Until Display
Reads
Use up or down
arrows and accept
Description to adjust the
Accesses display value if Accepts and saves
changeable Accesses Displays current using an external new parameter Sequences to next
parameters. parameter no. 9. digital display pressure sensor. setting. parameter.
3-6 seconds
Until Display
Reads
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 0 and 200) Flashing
Displays current
parameter value.
Incremental
value is:
Description 2 bar unit:
x 2 mbar x % P19
Accesses Accepts and saves
changeable Accesses 10 bar unit: new parameter Sequences to next
parameters. parameter no. 18. x 10 mbar x % P19 Edits parameter. setting. parameter.
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 0 and 100) Flashing
Displays current
parameter value.
Description Accesses Incremental Accepts and saves
changeable Accesses value is: new parameter Sequences to next
parameters. parameter no. 19. % of F.S. Edits parameter. setting. parameter.
Behavior Control
The regulation speed of the pressure regulator can be modified by means of one parameter. (P 20)
The value in this parameter has a range from 0-5. A higher value indicates slower regulation speed, but will be more stable.
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 0 and 5) Flashing
Edits parameter
0 = custom set*
1 = fastest (narrow
proportional band)
2 = fast
Description 3 = normal
4 = slow
Accesses 5 = slowest Accepts and saves
changeable Accesses Displays current (proportional new parameter Sequences to next
parameters. parameter no. 20. parameter value. band is broad) setting. parameter.
* When the value 0 is entered, you are able to create your own custom settings true parameters 12, 13 and 21.
Fine Settings
Set Proportional Band
Proportional band is used for setting the reaction sensitivity of the regulator. The displayed value is X 10 mbar and has a range
between 50 (0.5 bar) and 250 (2.5 bar).
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 50 and 250) Flashing
Displays current
parameter value.
Description Accesses Incremental Accepts and saves
changeable Accesses value is: new parameter Sequences to next
parameters. parameter no. 12. x 10 mbar Edits parameter. setting. parameter.
Set Deadband
Deadband is the Minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X 10 mbar and has a
range between 4 (40 mbar) and 40 (400 mbar).
Parameter Number 13 – Set Deadband (P20 Must be Set to 0)
Step 1 2 3 4 5
Press
or or
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 4 and 40) Flashing
Displays current
parameter value.
Description Incremental Accepts and saves
Accesses changeable Accesses parameter value is new parameter Sequences to next
parameters. no. 13. x 10 mbar Edits parameter. setting. parameter.
Proportional Effect
3-6 seconds
Until Display
Reads
Flashing Decimal
(value between
Flashing Decimal 5 and 100) Flashing
Edits parameter.
5 = fastest
Description Accesses regulation Accepts and saves
changeable Accesses Displays current 100 = slowest new parameter Sequences to next
parameters. parameter no. 21. parameter value. regulation. setting. parameter.
3-6 seconds
Until Display
Reads
Flashing Decimal
Displays current
Accesses parameter value.
Description changeable Accesses XXX = current
parameters. parameter no. 39. software version
3.51
(89)
4.99
(126.25)
1.47
(37.25)
2.25 0.79
(57) (20)
1.58
1.12 (40)
(28.5)
0.79
(20)
0.59 0.47
(15) (12)
0.28
(7)
0.98
(25) 2.20 0.39 1.02
(56) (10) (26)
0.28 1.18 0.28 1.18 2.05
(7) (52)
(30) (7) (30)
1.42
(36) 1.57
(40) Ø 0.28 (7)
2.05
(52) 4 holes
3.31
(84)
3.94
(100)
Cables
Description Part Number
Most popular.
4.16
(105.3)
6.94
(175.7)
2.54
(64.4)
2.96 1.13
(75) (28.6)
1.48 2.26
(37.5) (57.2)
1.13
(28.6)
0.59 0.47
(15) (12)
0.98
(25) 2.20 1.02
(56) (26)
1.18 1.77 2.05
(30) (45) (52)
3.31
(84)
3.94
(100)
Cables
Description Part Number
Most popular.
Gauge supplied with every part. Gauge can be installed on the front or back
of the regulator. If no gauge is installed, both seal screws must be installed.
P31EB 9 2 E G M B N 5 P
Basic Series Thread Type Element Adjustment Mounting
Global Modular Mini BSPP 1 5µ Element E Non-Rising Plastic Panel
P31EB N P
Filter / Regulator BSPT 2 Knob Mount Nut
NPT 9 Relief
Port Size B Relieving
1/4 2 N Non-Relieving
Most popular.
*For P31 Regulators with date code after November 2023 (4423 Date Code),
please use these part numbers when ordering a replacement gauge.
Manual Drain Pulse Drain
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
WARNING adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
Product rupture can cause serious injury. is not a limiting device. This is a common characteristic of most industrial
Do not connect regulator to bottled gas. regulators, and limiting devices may be obtained only by special design. For
Do not exceed Maximum primary pressure rating. best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
Ordering Information:
P32EB 9 2 E G M B N P
Basic Series Thread Type Element Adjustment Mounting
Global Modular Compact BSPP 1 5µ Element E Non-Rising Plastic Panel
P32EB N P
Filter / Regulator BSPT 2 Knob Mount Nut
NPT 9 Relief
B Relieving Adjustment Range
Port Size
N Non-Relieving With Round Gauge
1/4 2
Z 30 psig; 2 bar; 0.2 MPa
3/8 3
M 60 psig; 4 bar; 0.4 MPa
1/2 4
G 125 psig; 8 bar; 0.8 MPa
Bowl Type J§ 250 psig; 17 bar; 1.7 MPa
Poly Bowl with Bowl Guard G Without Gauge
Metal Bowl without Sight Gauge M Y 30 psig; 2 bar; 0.2 MPa
Metal Bowl with Sight Gauge S L 60 psig; 4 bar; 0.4 MPa
N 125 psig; 8 bar; 0.8 MPa
Drain Type
H§ 250 psig; 17 bar; 1.7 MPa
Manual Drain M
* Regulator comes with gauge respective
Auto Drain A to the adjustment range selected.
§ Not available with poly bowl with bowl
guard.
Most popular.
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed Maximum primary pressure rating.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
Gauges
50mm (2") round 0-30 psig / 0-2 bar K4520N14030
1/4" center back
0-60 psig / 0-4 bar K4520N14060
mount
0-160 psig / 0-11 bar K4520N14160
0-300 psig / 0-20 bar K4520N14300
For best performance, regulated pressure should always be set by increasing the
Manual Drain Automatic Drain pressure up to the desired setting.
1 2 Operating Information
Flow capacity*: 1/2 200 scfm (94 dm3/s, ANR)
3/4 235 scfm (109 dm3/s, ANR)
Operating temperature:
Port Description / Bowl / Plastic bowl -13°F to 125°F (-25°C to 52°C)
Size Relieving Drain Type ‡ Part Number Metal bowl -13°F to 150°F (-25°C to 65.5°C)
1/2" 125 psig (8 bar) Poly / Manual P33EA94EGMBNGP Supply pressure (max):
Plastic bowl 150 psig (10 bar)
1/2" 125 psig (8 bar) Poly / Auto P33EA94EGABNGP Metal bowl 250 psig (17 bar)
1/2" 125 psig (8 bar) Metal / Manual P33EA94ESMBNGP Standard filtration: 5 micron
Useful retention†: 2.8 US oz. (85 cm3)
1/2" 125 psig (8 bar) Metal / Auto P33EA94ESABNGP
Adjusting range pressure: 0 to 30 psig (0 to 2 bar)
3/4" 125 psig (8 bar) Poly / Manual P33EA96EGMBNGP 0 to 60 psig (0 to 4 bar)
0 to 125 psig (0 to 8 bar)
3/4" 125 psig (8 bar) Poly / Auto P33EA96EGABNGP
0 to 250 psig (0 to 17 bar)
3/4" 125 psig (8 bar) Metal / Manual P33EA96ESMBNGP Gauge port (2 each): 1/4 NPT, BSPP, BSPT
3/4" 125 psig (8 bar) Metal / Auto P33EA96ESABNGP Weight: 1.87 lb. (0.85 kg)
* Inlet pressure 145 psig (10 bar). Secondary pressure 91.3 psig (6.3 bar)
and 14.5 psig (1 bar) pressure drop.
‡
For polycarbonate bowl, see caution in Engineering Section A. †
Useful retention refers to volume below the quiet zone baffle.
Air quality: Within ISO 8573-1: 1991 Class 3 (Particulates)
Within ISO 8573-1: 2001 Class 6 (Particulates)
Ordering Information:
P33EA 9 6 E G M B N G P
Basic Series Thread Type Element Adjustment Mounting
Global Modular Standard BSPP 1 5µ Element E Non-Rising Plastic Panel
P33EA N P
Filter / Regulator BSPT 2 Knob Mount Nut
NPT 9
Relief Adjustment Range
Port Size B Relieving With Round Gauge
1/2 4 N Non-Relieving Z 30 psig; 2 bar; 0.2 MPa
3/4 6 M 60 psig; 4 bar; 0.4 MPa
Drain Type G 125 psig; 8 bar; 0.8 MPa
Bowl Type
M Manual Drain J§ 250 psig; 17 bar; 1.7 MPa
Poly Bowl with Bowl Guard G
A Auto Drain Without Gauge
Metal Bowl without Sight
M
Gauge Y 30 psig; 2 bar; 0.2 MPa
Metal Bowl with Sight Gauge S L 60 psig; 4 bar; 0.4 MPa
N 125 psig; 8 bar; 0.8 MPa
H§ 250 psig; 17 bar; 1.7 MPa
§ Not available with poly bowl with
bowl guard.
Most popular.
9
Plastic bowl / bowl guard, manual drain P33KA00BGM 120
WARNING
2.87 4.27 Round Product rupture can cause serious injury.
(73) (108) Gauge Do not connect regulator to bottled gas.
1.44 2.87 Do not exceed Maximum primary pressure rating.
(37) (73)
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
4.09 adjustment is designed to permit outlet pressures within their full range.
(104)
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
11.44 11.22
(291) (285)
Gauges
50mm (2") round 0-30 psig / 0-2 bar K4520N14030
1/4" center back
0-60 psig / 0-4 bar K4520N14060
mount
0-160 psig / 0-11 bar K4520N14160
0-300 psig / 0-20 bar K4520N14300
Use 10mm or For best performance, regulated pressure should always be set by increasing the
.18 (4.8mm) 2.00 Bowl 2.83 pressure up to the desired setting.
3/8" Flex Tubing
I.D. tube (51) removal (72)
barb fitting clearance
Inches (mm)
1 2
Lubricator
with drain
Operating Information
Flow capacity*:
Port 1/4 52 scfm (25 dm3/s, ANR)
Size Description ‡ Part Number Operating temperature:
Plastic bowl 14°F to 125°F (-10°C to 52°C)
1/4" Poly Bowl - No Drain P31LB92LGNN Metal bowl 14°F to 150°F (-10°C to 65.5°C)
Supply pressure (max):
1/4" Metal Bowl - No Drain P31LB92LMNN Plastic bowl 150 psig (10 bar)
‡
For polycarbonate bowl, see caution in Engineering Section A.
Metal bowl 250 psig (17 bar)
Bowl capacity: 0.6 US oz. (18 cm3)
Weight: 0.29 lb (0.13 kg)
* Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
Ordering Information:
P31LB 9 2 L G N N
Basic Series Thread Type Mounting
Global Modular BSPP 1 N No Bracket
P31LB
Mini Lubricator BSPT 2
Drain Type
NPT 9
N No Drain Closed End
Port Size
Bowl Type
1/4 2
G Poly Bowl with Bowl Guard
Lube Type M Metal Bowl without Sight Gauge
Oil Mist Standard Sight L
Dome
Most popular.
0 20 40 60 80 100
Metal bowl / w/o sight gauge no drain P31KB00BMN
Flow - (scfm)
Drip control assembly P32KA00PG
Fill plug P31KA00PL
C-bracket (fits to body) P31KA00MW
T-bracket with body connector P31KA00MT
Body connector P31KA00CB
Oil (1 quart) F442001
Oil (1 galllon) F442002
Oil (12 quart case) F442003
Oil (4 gallon case) F442005
1.58
(40)
1.58 0.79
(40) (20)
2.22
(56.3)
6.04
(153.3)
1.30 Bowl
(33) removal
clearance
Inches (mm)
1 2
Lubricator
with drain
Operating Information
Flow capacity*:
Port 1/4 38 scfm (17 dm3/s, ANR)
Size Description ‡
Part Number 3/8 70 scfm (33 dm3/s, ANR)
1/2 90 scfm (42 dm3/s, ANR)
1/4" Poly Bowl - No Drain P32LB92LGNN
Operating temperature:
1/4" Metal Bowl - No Drain P32LB92LSNN Plastic bowl 14°F to 125°F (-10°C to 52°C)
Metal bowl 14°F to 150°F (-10°C to 65.5°C)
3/8" Poly Bowl - No Drain P32LB93LGNN
Supply pressure (max):
3/8" Metal Bowl - No Drain P32LB93LSNN Plastic bowl 150 psig (10 bar)
Metal bowl 250 psig (17 bar)
1/2" Poly Bowl - No Drain P32LB94LGNN Bowl capacity: 4.09 US oz. (121 cm3)
1/2" Metal Bowl - No Drain P32LB94LSNN Weight: 0.68 lb (0.31 kg)
‡
For polycarbonate bowl, see caution in Engineering Section A. * Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
Ordering Information:
P32LB 9 2 L G N N
Basic Series Thread Type Mounting
Global Modular BSPP 1 N No Bracket
P32LB
Compact Lubricator BSPT 2
Drain Type
NPT 9
N No Drain Closed End
Port Size
Bowl Type
1/4 2
G Poly Bowl with Bowl Guard
3/8 3
Metal Bowl with Sight
1/2 4 S
Gauge
Lube Type
Oil Mist Standard Sight L
Dome
Most popular.
3 0.2
T-bracket (fits to body connector) P32KA00MB
2
T-bracket with body connector P32KA00MT 1
0.1
6 0.4
Pressure Drop - (psig)
2.36 5
(60) 0.3
2.36 1.18 4
(60) (30) 3 0.2
2
0.1
1
2.45 0 0
0 10 20 30 40 50 60 70 80
(62.3) Flow - (dm 3/s)
n
8.56
(217.3)
2.28 Bowl
removal
(58) clearance
Inches (mm)
1 2
Lubricator
with drain
Operating Information
Flow capacity*:
1/2 110 scfm (52 dm3/s, ANR)
3/4 150 scfm (71 dm3/s, ANR)
Port Operating temperature:
Size Description ‡ Part Number Plastic bowl 14°F to 125°F (-10°C to 52°C)
Metal bowl 14°F to 150°F (-10°C to 65.5°C)
1/2" Poly Bowl - No Drain P33LA94LGNN
Supply pressure (max):
1/2" Metal Bowl - No Drain P33LA94LSNN Plastic bowl 150 psig (10 bar)
Metal bowl 250 psig (17 bar)
3/4" Poly Bowl - No Drain P33LA96LGNN Bowl capacity: 6.1 US oz. (181 cm3)
3/4" Metal Bowl - No Drain P33LA96LSNN Weight: 1.04 lb (0.47 kg)
‡
For polycarbonate bowl, see caution in Engineering Section A. * Inlet pressure 91.3 psig (6.3 bar). Pressure drop 4.9 psig (0.34 bar).
Ordering Information:
P33LA 9 6 L G N N
Basic Series Thread Type Mounting
Global Modular BSPP 1 N No Bracket
P33LA
Standard Lubricator BSPT 2
Drain Type
NPT 9
N No Drain Closed End
Port Size
Bowl Type
1/2 4
G Poly Bowl with Bowl Guard
3/4 6
Metal Bowl with Sight
S
Lube Type Gauge
Oil Mist Standard Sight Dome L
Most popular.
3 0.2
Sight gauge Nylon
2
Suggested lubricant ISO / ASTM VG32 0.1
1
Pick-up filter Sintered bronze 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120
Flow - (dm 3/s)
n
Repair and Service Kits 0 20 40 60 80 100 120 140 160 180 200 220 240
Flow - (scfm)
Plastic bowl / bowl guard no drain P33KA00BGN
Metal bowl / w/o sight gauge no drain P33KA00BMN
P33LA 3/4" Lubricator
Metal bowl / sight gauge no drain P33KA00BSN Primary Pressure - bar 1.6 4.0 6.3
Primary Pressure - psig 23.2 58 91.4
Drip control assembly P32KA00PG 7 0.5
2.90
(73)
1.44 2.90
(36) (73)
2.00
(51)
9.20
(234)
2.00 Bowl
(51) removal
clearance
Inches (mm)
Popular Combinations: Inlet pressure 145 psig (10 bar), secondary pressure 100 psig (6.9 bar), 14.5 psig (1 bar) pressure drop.
Filter + Regulator + Lubricator Combinations, poly bowl
5 micron element, 116 psig (8 bar) regulator + gauge and wall mounting brackets
Port Size Flow Manual Drain Pulse Drain
1/4" 27 scfm (13 dm3/s, ANR) P31CB92GEMN5LNW P31CB92GEBN5LNW
P31 C B 9 2 G E M N 5 L N W
Popular Combinations: Inlet pressure 145 psig (10 bar), secondary pressure 91.3 psig (6.3 bar), 14.5 psig (1 bar) pressure drop.
Filter + Regulator + Lubricator Combinations, poly bowl
5 micron element, 116 psig (8 bar) regulator + gauge and wall mounting brackets
Port Size Flow Manual Drain Auto Drain
1/4" 42 scfm (20 dm3/s, ANR) P32CB92GEMNGLNW P32CB92GEANGLNW
3/8" 68 scfm (32 dm3/s, ANR) P32CB93GEMNGLNW P32CB93GEANGLNW
1/2" 85 scfm (40 dm3/s, ANR) P32CB94GEMNGLNW P32CB94GEANGLNW
P32 C B 9 4 G E M N G L N W
Popular Combinations: Inlet pressure 145 psig (10 bar), secondary pressure 91.3 psig (6.3 bar), 14.5 psig (1 bar) pressure drop.
Filter + Regulator + Lubricator Combinations, poly bowl
5 micron element, 116 psig (8 bar) regulator + gauge and wall mounting brackets
Port Size Flow Manual Drain Auto Drain
1/2" 90 scfm (43 dm3/s, ANR) P33CB94GEMNGLNW P33CB94GEANGLNW
3/4" 110 scfm (52 dm3/s, ANR) P33CB96GEMNGLNW P33CB96GEANGLNW
P33 C B 9 6 G E M N G L N W
P32 COMBO
DIMENSIONS TO BE
UPDATED SOON
Ordering Information:
P31DA 9 2 S G N C 2CN
Body Size Actuator Interface Solenoid Voltage
Dump Valve (1/4") P31DA 15mm Solenoid (P31 2CN 24VDC Non Locking Manual Override
G
Dump Valve (1/2") P32DA only) 3GN 120VAC Non Locking Manual Override
C 30mm Solenoid 120VAC Non Locking Manual Override
Thread Type 1FN
P Threaded Air Pilot (P31 series only)
BSPP 1
BSPT 2 Pilot Type Solenoid Type
NPT 9 External Air C 15mm (P31 series only)
P
Pilot A 30mm CNOMO Coil (P32 only)
Port Size S Solenoid Pilot 30mm CNOMO Coil
Note: Global Modular Mini (1/4") 2 D
P32 unit used for both
(M12 connection) (P32 only)
P32 & P33 series Global Modular Compact (1/2") 4
Most popular.
100 7 10 bar
Note:
For solenoid operators and cable plugs (connectors) see pages 87 and 88.
P32DA 1/2" Remote Dump Valve
10 bar
Inlet Pressure - 6.3 bar (91.3 psig) 145 psig
8
9.0 bar
6.3 bar 130.5 psig
100 7 8.0 bar
91.4 psig
2
20
1
0 0
0 20 40 60 80 100 120 140 150
Flow - (dm 3/s)
n
5.35
(136) 1/8"
6.53 Gauge
3.30 6.87 1/4"
(166) Port
(84) (174.5) Gauge
Port
1.45 8.95
(37) 4.31
(227.3) (109.5)
1.20 2.53
(30.5) (64.5)
0.15
(4)
1.57 2.08
(40) (53)
0.94
(24)
2.24 0.23
(57) 2.25 (6)
(57.2)
1.02
2.95 (26)
Most popular. (75)
Parker Global Series Soft Start Valves, provide for the safe
introduction of pressure to machines or systems. Soft Start
Valves, allow the pressure to gradually build to the set point
before fully opening to deliver full flow at line pressure.
The controlled introduction of pressure can be an important
Operating Information
safety factor and prevent damage to tooling when air pressure is
introduced at machine or system start up. Flow capacity*: P31S 36 scfm (17 dm3/s, ANR)
P32S 101 scfm (48 dm3/s, ANR)
Note: Soft Start Valves must be installed downstream of
Temperature range (max)†:
a 3/2 valve with exhaust capability
Solenoid operated 14°F to 122°F (-10°C to 50°C)
Port Weight Air pilot operated -4°F to 176°F (-20°C to 80°C)
Size Description Lbs (Kg) Part Number Pressure (max):
Solenoid operated 150 psig (10 bar)
1/4" 120VAC Solenoid & Cable Plug 0.8 (0.37) P31SA92SGNC1FN
Air pilot operated 250 psig (17 bar)
1/4" 24VDC Solenoid & Cable Plug 0.9 (0.41) P31SA92SGNC2CN Operating pressure (min): 44 psig (3 bar)
1/4" Internal Air Pilot Operated 0.8 (0.37) P31SA92Y0N Fluid: Compressed air
1/4" External Air Pilot (1/8" threaded) 0.8 (0.37) P31SA92PPN Ports: Air pilot 1/8
Gauge P31S - 1/8; P32S - 1/4
1/2" 120VAC 30mm Coil & Cable Plug incl. 1.5 (0.87) P32SA94SCNA3GN * Inlet pressure 91.3 psig (6.3 bar), inlet pressure and
1/2" 24VDC 30mm Coil & Cable Plug 2.0 (0.90) P32SA94SCNA2CN 14.5 psig (1 bar) pressure drop.
† Air supply must be dry enough to avoid ice formation at temperatures
1/2" Internal Air Pilot Operated 2.0 (0.90) P32SA94Y0N below 35.6°F (2°C). Snap pressure: Full flow when downstream
pressure reaches 50% of the inlet pressure.
1/2" External Air Pilot (1/8 threaded) 1.5 (0.87) P32SA94PPN
Ordering Information:
P31SA 9 2 S G N C 2CN
Body Size Actuator Interface Solenoid Voltage
Soft Start P31SA 0 Internal Pilot 2CN 24VDC Non Locking Manual Override
Soft Start P32SA G 15mm Solenoid (P31 Only) 3GN 120VAC Non Locking Manual Override
C 30mm Solenoid 120VAC Non Locking Manual Override
Thread Type 1FN
P Threaded Air Pilot (P31 series only)
BSPP 1
BSPT 2 Pilot Type Solenoid Type
NPT 9 P External Air Pilot C 15mm (P31 series only)
S Solenoid Pilot A 30mm CNOMO Coil (P32 only)
Port Size
Note:
Global Modular Mini (1/4") 2 Y Internal Air Pilot 30mm CNOMO Coil
P32 unit used for both D
(M12 connection) (P32 only)
P32 & P33 series Global Modular Compact (1/2") 4
Most popular.
0 20 40 60 80 100 120
Flow - (scfm)
40 3 3.0 bar
43.5 psig
2
20
1
0 0
0 20 40 60 80 100 120 140
Flow - (dm 3/s)
n
(73)
6.53
(166) 1/8"
Gauge 1/4"
5.35 Port 6.87
(174.5) Gauge
(136) Port
1.45
(37) 4.31
(109.5)
2.53
(64.5)
90%
2.24 2.25
(57) (57.2)
3
1 0% 1 Start signal
2 2 Switching time delay 2.95
3 Gradual pressure build up (75)
Time (t) 4 Operating pressure p2 (=p1)
3 1
Parker Global Series Combined Soft Start / Dump Valves, provide for
the safe introduction of pressure to machines or systems. Soft Start / Operating Information
Dump Valves when set, allow the pressure to gradually build to the set Flow capacity*: P31T 36 scfm (17 dm3/s, ANR)
point before fully opening to deliver full flow at line pressure. P32T 97 scfm (46 dm3/s, ANR)
The controlled introduction of pressure can be an important safety Temperature range (max)†:
Solenoid operated 14°F to 122°F (-10°C to 50°C)
factor and prevent damage to tooling when air pressure is introduced at Air pilot operated -4°F to 176°F (-20°C to 80°C)
machine or system start up.
Pressure (max):
To maintain these units in the open position a pilot supply to the air Solenoid operated 150 psig (10 bar)
pilot operated version or an electrical signal to the solenoid operated Air pilot operated 250 psig (17 bar)
version must be maintained. The valve will automatically dump when Operating pressure (min): 44 psig (3 bar)
the holding signal is removed. Fluid: Compressed air
Ports: Air pilot 1/8
Port Weight Exhaust P31T - 1/4; P32T - 1/2
Size Description lbs (kg) Part Number
Gauge P31T - 1/8; P32T - 1/4
1/4" 120VAC Solenoid & cable plug 0.8 (0.37) P31TA92SGNC1FN * Inlet pressure 91.3 psig (6.3 bar), inlet pressure and
1/4" 24VDC Solenoid & cable plug 0.9 (0.41) P31TA92SGNC2CN 14.5 psig (1 bar) pressure drop.
† Air supply must be dry enough to avoid ice formation at temperatures
1/2" 120VAC 30mm coil & cable plug incl. 1.9 (0.87) P32TA94SCNA3GN below 35.6°F (2°C). Snap pressure: Full flow when downstream
1/2" 24VDC 30mm coil & cable plug incl. 2.0 (0.91) P32TA94SCNA2CN pressure reaches 50% of the inlet pressure.
Ordering Information:
Solenoid type only
P31TA 9 2 S G N C 2CN
Body Size Actuator Interface Solenoid Voltage
Soft Start / Dump Valve (1/4") P31TA 15mm Solenoid (P31 2CN 24VDC Non Locking Manual Override
G
Soft Start / Dump Valve (1/2") P32TA only) 3GN 120VAC Non Locking Manual Override
C 30mm Solenoid 120VAC Non Locking Manual Override
Thread Type 1FN
P Threaded Air Pilot (P31 series only)
BSPP 1
Pilot Type Solenoid Type
BSPT 2
External Air C 15mm (P31 series only)
NPT 9 P
Pilot A 30mm CNOMO Coil (P32 only)
Port Size S Solenoid Pilot
Note:
30mm CNOMO Coil
Global Modular Mini (1/4") 2 D
P32 unit used for both (M12 connection) (P32 only)
P32 & P33 series Global Modular Compact (1/2") 4
Most popular.
100 7 10 bar
0
Note: 0 5 10 15 20 25 30 35 40 45 50 55 60 65
For solenoid operators and cable plugs (connectors) see pages 87 and 88. Flow - (dm 3/s)
n
0 20 40 60 80 100 120
Flow - (scfm)
0 0
0 20 40 60 80 100 120 140
Flow - (dm 3/s)
n
(73)
5
5.35
1/8" 6.87 1/4"
6.53 (136) Gauge
(166) Gauge (174.5)
3.30 Port
Port 8.95
(84) 4.31
(227.3)
1.45 (109.5)
(37) 2.53
(64.5)
1.20
(30.5)
0.15
(4)
2.08
(53)
Soft Start Function: 1.57
100% 4 (40)
Pressure (p)
0.94 0.23
90%
(24) 2.25 (6)
2.24
3 (57.2)
(57)
1 0%
1 Start signal
2
2 Switching time delay 1.02
Time (t)
3 Gradual pressure build up 2.95 (26)
4 Operating pressure p2 (=p1) (75)
advantage
• Solid state pressure sensors provide accurate, fast 1
3
2
fault detection
• Quick visual LED indicators on the front of the valve
• Superior seated seal design for longer life
• Safety exhaust outlet is no-maintenance and
non-clog by design
• Suitable for stand alone use or modular mounting to
P32 or P33 FRL assembly
• High B10 life value
• Fast exhaust times allow for smaller machine
footprint
Ordering Information:
P3 3 T B 1 6 A B E N
Global Design Port Size Sensor Gauge 2
Standard 3 Current B Monitoring No Gauge N
3/4" 1 6
External E Dial Gauge 3
Series Type Thread Type G
(standard)
Standard P3 Safety Redundant D
BSPP 1 Output for Solenoid, Output for Sensors, Digital
(no soft start) M12 Connector Pin M12 Connector Pin D
NPT 9 Gauge 3
Safety Redundant 2 & 4, Common 3 A 1 & 2, 1 & 4, Common 3 A MPS-P34
T
(c/w soft start) Pressure M
3&4 C 1 & 2, 5 & 4, Common 3 B
Sensor
2&4 D 5 & 2, 1 & 4, Common 3 C
Notes:
1. For 1/2" connections use 1/2" port blocks on standard 3/4" housing.
2. Safety valve supplied with 1/8" gauge port in either BSPP or NPT
threads as specified for ports. Gauges shipped loose. Note: Mounting hardware and port blocks are sold separately.
3. Dial or digital gauge not available on BSPP version.
Most popular.
3 3 3
Operating voltage (DC) 21.6 to 26.4 - - -
Nominal power
per solenoid coil at 24V DC (W) +/- 10% 1.2 W
per pressure sensor at 24V DC 1.2 W
Pressure Sensor M12 Pinouts
In accordance with EN ISO 13849-1 this safety valve is suitable for use up to
A B C
Category 4, Ple, sil 3. Certified to cCSAus and bears the CE mark. + + + + +
4 SW SW 2
1
5 4 SW SW
1
SW
2 5 2 5 4
to the Parker Safety Exhaust Valve under the Product Support tab at www. A
3
B A
3
B A
3
B
parker.com/pdn/safetyvalve - - -
E A
D D
B C B C
The externally monitored valve has the monitoring done via a PLC or relay
which offers a size and cost advantage over internally monitored valves. The
integration of a safety interface into the PLC or relay will help determined the Cat 4, PL e
achievable category and performance level of the control system. Customers
are required to provide the logic function via the safety device. The valve will
lock-out to the “safe state” if asynchronous movement of the valve elements
occur which will be detected by solid state pressure sensors. To achieve the
proper safety rating, the safety PLC or relay must monitor the solid state
pressure sensors to ensure they are not in different states for more than
Safety
150ms. If the sensors are in different states for longer than 150ms then the
relay
programming logic must shut off power to the solenoids and consider it a
fault condition. If during operation the externally monitored P33 enters a fault Safety
PLC
condition the valve will shut off. A separate reset signal must be incorporated
into the logic sequence to avoid automatic restart of the valve. The safety
exhaust valves are not for use with clutch or brake applications and are
designed for use in conjunction with a safety relay or safety PLC for safe Reset button
monitoring and fault detection.
Achieving Desired Performance Level **
The category and performance level (PLr) needed for your machine is
determined by a risk assessment of the machinery design and application * For information on internally monitored safety valves
based on EN ISO 13849-1. The Parker P33 safety valve is designed for those reference Bulletin 0700-B13.
applications requiring a PL of d or e. Please note these levels require other ** An integration guide is available to provide further
aspects of the system to meet these requirements. As a guide: you can achieve information on connecting the safety valve product to
a Cat 4 PL e system by integrating monitoring via a programmable safety rated achieve the desired performance level. Please consult
device. Because the P33 is a mechanical fail-safe device, the monitoring could Parker and the standard EN ISO 13849-1 for more infor-
also be done via a standard PLC and still attain as high as a PL d rating. mation.
Conditions at Start
B A The Safety exhaust valve starts with inlet 1 closed to outlet 2 by both valve elements A and B. Outlet 2 is open to exhaust 3.
Pressure signals at both sensors SA and SB are exhausted and contacts 1 and 2 of sensors SA and SB are connected. The
normally closed sensors both provide voltage feedback signals to the external monitoring system.
2
+ -
Output
1
+ -
Output
3 Normal Operation
SB SA
During normal operation the two solenoids are simultaneously energized which actuates both pilots and causes valve
elements A and B to shift. Inlet 1 is then connected to outlet 2 via crossflow passages C and D. Exhaust 3 is closed. Sensing
pressure signals go to each pressure sensor and become equal to inlet pressure. Both sensors contacts open and no
B A
CD voltage signals are provided to the external monitoring system. This indicates that both sides of the valve actuated as
expected.
+ - + - 3 Detecting a Malfunction
2 1
SB
Output
SA
Output
A malfunction in the system or the valve itself could cause one valve element to be open and the other closed. Air then
flows past the inlet poppet on valve element A, into crossflow passage D, but is substantially blocked by the spool portion
of element B. The large size of the open exhaust passage past element B keeps the pressure at the outlet port below 2%
B A of inlet pressure. Full sensing air pressure from side A goes to sensor SA, and a reduced pressure goes to sensor SB. This
CD
full pressure signal causes SA to open. Sensor SB, with a reduced pressure signal, does not open. An external monitoring
system can detect the malfunction by monitoring the outputs of the SA and SB sensors. The external monitor system must
+
then react accordingly by shutting down the power to the valve solenoids and any other components deemed necessary to
- + -
2
Output
1 Output
3
stop the machine.
SB SA
PLr < PL
The Safety Lockout valves conform to OSHA #29 CFR part 1910
— control of hazardous energy source (lockout / tagout).
Operating Information
Operating temperature: -40°C to 80°C (-40°F to 176°F)
Pressure supply (max): 250 psig (17 bar)
Port size:
Ordering Information BSPP / BSPT / NPT 1/4, 3/8, 1/2, 3/4
Modular Ball Weight: P31 0.33 lbs (0.15 kg)
Model Port Exhaust Thread Flow scfm Valve Flow from P32 0.79 lbs (0.36 kg)
Type Size Port Type (dm3/s, ANR) Left to Right P33 1.21 lbs (0.55 kg)
P31 1/4" 1/4" NPT 42.4 (20) P31VB92LBNN
P32 3/8" 1/4" NPT 190.7 (90) P32VB93LBNN
1/2" 1/4" NPT 258.5 (122) P32VB94LBNN
Material Specifications
P33 1/2" 1/2" NPT 561.5 (265) P33VB94LBNN Body Aluminum
Seals PTFE
3/4" 1/2" NPT 678 (320) P33VB96LBNN
Ball Stainless Steel
* Lockout tab and muffler supplied with unit.
For thread type: BSPP 1 Lockout Tab Zinc Plated Steel
BSPT 2 Screw Zinc Plated Steel
NPT 9
3.25
2.87 (82.6)
0.82 1.96 (73)
(21) (50)
(
3.46 3.87
2.81 (88) (98.4)
(71.4)
1.00 1.44
0.84 (25.4) (36.5)
(21.4)
1/4 Thread 1/4 Thread 1/2 Thread
Port Port Port
Most popular.
Manifold Blocks
• Available in 1/4" or 3/4" threaded inlet / outlet ports
• Two additional top and bottom auxiliary ports standard
• Can be mounted anywhere in the FRL system
Ordering Information
Operating Information
Auxiliary Auxilliary
Model In / Out Port Size Port Size Thread Operating temperature: -40°F to 150°F (-40°C to 65.5°C)
Type Port Size Top Bottom Type Part Number Pressure supply (max): 300 psig (20.7 bar)
P31 1/4" 1/4" 1/4" NPT P31MA92022N Weight: P31 0.26 lbs (0.12 kg)
P32 1/2" 1/4" 1/2" NPT P32MA94024N P32 0.45 lbs (0.20 kg)
P33 0.45 lbs (0.20 kg)
P33 3/4" 1/4" 1/2" NPT P33MA96024N
For thread type: BSPP 1
BSPT 2
NPT 9
Material Specifications
Body Aluminum
1.58 1.30
Top & 0.94 1.18 (33)
Inlet (40)
Outlet Bottom (23.9) 2.60
1.88 (30)
Port Port Aux. Ports (66)
1/4" 1/4" 0.74 1/4" (47.8)
FLOW
(19) 0.94
1.61 1.58 1.88 (23.9) 1.88
(41) (40) (47.8) (47.8)
0.94
(23.9)
Bottom Port
1/2"
Bottom Port
1/2"
Most popular.
1
• Field adjustable
(Common) 2 (Normally Closed)
• Compact design
• Easily customized
• Quick delivery
• NEMA 4, 13
Definitions and Terminology
Repeatability — Accuracy is the maximum allowable set point
deviation of a single pressure or temperature switch under one
given set of environmental and operational conditions. Operating Information
Single Pole Double Throw (SPDT) Switching element — Temperature range: -40°F to 105°F (-40°C to 220°C)
A SPDT switching element has one normally open, one normally Operating pressure range: 1, 2, 3 - 250 PSI (17.2 bar)
closed and one common terminal. Three terminals mean that the 4 - 2000 PSI (137.9 bar)
switch can be wired with the circuit either normally open (NO), or Set point tolerance ±1 PSI or 5% (.07 bar)
normally closed (NC), or both. Deadband 10 - 20% of set pressure
Dead Band — The dead band, sometimes referred to as Current rating 3A @ 125 VAC
2A @ 30 VDC (Resistive)
“differential” or “hysteresis”, is the change in pressure between
actuation and deactuation set points. Circuit form SPDT Standard
Cycle life 1 Million
Ordering Information:
PPS1 - 1 C 3 - R HM
Thread Set Point Direction Electrical Connection
1/4" NPT Male 1 R Rising HM DIN 9.4mm
1/8" NPT Male 2 WL Wire Leads 18"
1/4" BSPP Male 17 Range*
1/8" BSPP Male 18 * Factory setting for calibration purposes
1 3-10 PSI
Range 1 = 6 PSI
2 6-30 PSI
Circuit Range 2 = 18 PSI
3 20-120 PSI Range 3 = 70 PSI
SPDT C
4† 100-400 PSI Range 4 = 250 PSI
†
Only available in 1/4" NPT
Note: Switch is field adjustable.
Material Specifications
Adjustment knob Anodized aluminum
Wire Configuration
Body Brass Top View DIN Pin 1 - Common (Black)
Pin 2 - N.C. (Blue)
Diaphragm Nitrile 3 Pin 3 - N.O. (Red)
1.50 2 1 1.20 Ø
(38.1)
GND
(30.5)
Operation Pin Configuration 18" Leads
Pin 1 - Common (Black)
The pressure switch monitors Pin 2 - N.C. (Blue)
the air pressure in your Pin 3 - N.O. (Red)
2.50
pneumatic system. When the (63.5) 2.30
(58.4)
pressure in your system either Max.
Max.
drops below or exceeds the set
point pressure, an electrical
1-1/8 Hex 1-1/8 Hex
output is given.
1/8-27 NPT 1/4-18 NPTF
P31 Accessories
C-Bracket T-Bracket w/ Body Connector
(Fits to filter and lubricator body) (O-ring not shown)
P31KA00MW 2.68 P31KA00MT
0.28
(68) (7)
1.67 0.39
(42.5) 0.26 (10) 0.22
0.39 (6.6) (5.5)
(10)
1.40
(35.5)
0.76 Dia
(19.3) 3.54
2.44 (90)
0.08
(62) (2)
1.42
(36)
0.94
(24)
P32 Accessories
T-Bracket w/ Body Connector Body Connector
P32KA00MT P32KA00CB
0.35
0.35 (8.9)
(8.9)
O-Ring
O-Ring
O-Ring
O-Ring 0.87 Dia.
(22.1)
0.87 Dia.
(22.1)
2.83
(72)
1.57 1.57
(40) (39.9)
L-Bracket T-Bracket
(Fits to filter and lubricator body) (fits to body connector or port block)
P32KA00ML P32KA00MB
2.74
0.75 0.29 (Typ.)
(69.5)
(19) (7.5)
0.54 0.28
(14) 1.66
(42) (7.1)
0.38
(9.6) 2.25
(57) Dia
1.10 1.00
(28)
4.53 (25.4)
0.88 (115)
2.84 (22)
(72) 0.28
1.26 (7.0)
(32)
0.79
(20)
P33 Accessories
T-Bracket w/ Body Connector Body Connector
P32KA00MT P32KA00CB
0.35
0.35 (8.9)
(8.9)
O-Ring
O-Ring
O-Ring
O-Ring 0.87 Dia.
(22.1)
0.87 Dia.
(22.1)
3.33
(84.5)
1.92
1.57 (49)
(40)
L-Bracket T-Bracket
(Fits to filter and lubricator body) (fits to body connector or port block)
P33KA00ML P32KA00MB
76
(3.00) 0.75 0.29 (Typ.)
14 48 7.1 (19) (7.5)
(.56) (1.88) (.28)
9.6
(.38)
67.5 Dia
28 (2.66)
(1.10)
1.00
28 4.53 (25.4)
87 (1.10) (115)
(3.44)
38
(1.49) 0.28
(7.0)
0.79
(20)
P31 P31KA00MP
P32 Panel Mount Nut (Plastic) P32KA00MP
P33 P33KA00MP
P31 P31KA00MM
P32 Panel Mount Nut (Aluminum) P32KA00MM
P33 P33KA00MM
P31 P31KA00ESE
P32 5µ Element Kit P32KA00ESE
P33 P33KA00ESE
P31 P31KA00ES9
P32 1µ Element Kit P32KA00ES9
P33 P33KA00ES9
P31 P31KA00ESC
P32 0.01µ Element Kit P32KA00ESC
P33 P33KA00ESC
P31 P31KA00ESA
P32 Adsorber Element Kit P32KA00ESA
P33 P33KA00ESA
P31 P31KB00RQ
Differential Pressure Indicator Kit
P32 / P33 P32KA00RQ
P31 P31KA00PL
Fill Plug Kit
P32 / P33 P32KA00PL
P31 P31KB00BGN
P32 Lubricator - Plastic Bowl w/ Bowl Guard No Drain P32KB00BGN
P33 P33KA00BGN
P31 P31KB00BMN
P32 Lubricator - Metal Bowl w/o Sight Gauge No Drain P32KB00BMN
P33 P33KA00BMN
P32 P32KB00BSN
Lubricator - Metal Bowl w/ Sight Gauge No Drain
P33 P33KA00BSN
P31 P31KB00BMM
P32 Metal Bowl w/o Sight Gauge & Manual Drain P32KB00BMM
P33 P33KA00BMM
P31 Metal Bowl w/o Sight Gauge & Pulse Drain P31KB00BMB
P32 P32KB00BMA
Metal Bowl w/o Sight Gauge & Auto Drain
P33 P33KA00BMA
P32 P32KB00BSM
Metal Bowl w/ Sight Gauge & Manual Drain
P33 P33KA00BSM
P32 P32KB00BSA
Metal Bowl w/ Sight Gauge & Auto Drain
P33 P33KA00BSA
P31 P31KB00BGM
P32 Plastic Bowl w/ Bowl Guard & Manual Drain P32KB00BGM
P33 P33KA00BGM
P32 P32KB00BGA
Plastic Bowl w/ Bowl Guard & Auto Drain
P33 P33KA00BGA
P33 Regulator - Main Adjusting Spring 0-30 psig (0-2 bar) Kit P33KA00PR
P33 Regulator - Main Adjusting Spring 0-60 psig (0-4.1 bar) Kit P33KA00PS
P33 Regulator - Main Adjusting Spring 0-125 psig (0-8.6 bar) Kit P33KA00PT
P33 Regulator - Main Adjusting Spring 0-250 psig (0-17 bar) Kit P33KA00PV
0.59
0-60 psig K4511SCR060 (15)
K4515N18160
(25)
0-160 psig / 0-10 bar 1/8"
P31 P31KB00AL
Tamperproof Lockable Kit
P32 P32KB00AL
‰
1
Most popular.
(30) (22)
0
(15)
1
0.13 1.61
1.00 (3.4)
(25.4) 1.77 (41) 1.30 PS2028BP PS243079BP PS203279BP
(45) 1.22 (33)
(31) PS2028JBP PS2430J79BP PS2032J79CP
1.57
(40) PS2429BP PS243083BP PS203283BP
0.87
2.01 (22) PS2429JBP PS2430J83BP PS2032J83CP
30 x 30mm 2.36 (51)
(60) PS2932BP PS294679BP PS294683BP
1.18
PS2932JBP PS2946J79BP PS2946J83BP
(30)
1.89
(48)
1.42 1.22
(36) (31)
0.87
2.05 (22)
2.36 (52)
(60)
1.57
(40)
1.22
(31)
1.18
(30)
1.65
1.87 (42)
(47.5)
0.22 1.22
(5.5) (31)
1.18
0.82 (30) 1.26
(32)
(20.8)
M3 1.22 0.20
(31) (5)
Most popular.
P3Y System
The P3Y system allows units to be connected together The P3Y regulators are designed to provide quick response
without the use of pipe connectors. This saves space, and accurate pressure regulation for the most demanding
provides constant mounting centers, and maintains a modern hi-flow industrial applications.
aesthetically pleasing appearance. The rolling diaphragm was designed for long trouble-free
The P3Y filters are specially designed to efficiently filter out operation and will not rupture or tear under high cycle
rust, dirt, moisture and other impurities from compressed or demanding applications. The P3Y mist lubricators are
air lines. Operation is fully automatic with a minimum of designed to provide lubrication for many general purpose
pressure drop. Coalescing filters and adsorber filters for high applications.
purity air are also included in the P3Y series.
Wall mounting
bracket
Combined manual /
semi-auto drain &
auto drain options
1 2 1 2
Operating Information
Manual drain Auto drain
Supply pressure (max)*: 254 psig (17.5 bar)
Operating temperature:
Auto drain 14°F to 140°F (-10°C to 60°C)
Combined drain -40°F to 140°F (-40°C to 60°C)
Standard filtration 5 micron
Port
Manual / semi-auto drain: Closed at 11.6 psig (0.8 bar)
Size Description Part Number
G1/8 thread male
3/4" Combined Manual /Semi-Auto Drain P3YFA96ESCN Auto drain bowl pressure: Closed at 11.6 psig (0.8 bar)
3/4" Auto Drain P3YFA96ESAN Bowl capacity: 4.4 US oz. (130 cm3)
1" Combined Manual /Semi Auto Drain P3YFA98ESCN Standard filtration: 5 micron
1" Auto Drain P3YFA98ESAN Flow capacity : †
3/4" 170 scfm (80.2 dm3/s, ANR)
1" 170 scfm (80.2 dm3/s, ANR)
Fluid: Compressed air
Weight: 1.98 lb (0.9 kg)
†
Inlet pressure 91.4 psig (6.3 bar) inlet pressure and 7.3 psig (0.5 bar)
pressure drop.
* Air supply must be dry enough to avoid ice formation at temperatures below
35.6°F (2°C).
Air quality:
Within ISO 8573-1: 1991 Class 3 and 5 (Particulates)
Within ISO 8573-1: 2001 Class 6 and 7 (Particulates)
Ordering Information:
P3YFA 9 6 E SC N
Basic Series Thread Type* Port Size Element Drain Type
Filter P3YFA BSPP 1 3/4 6 E 5 micron Combined
NPT 9 1 8 SC Manual / Semi-
Auto Drain
* Note: For 1-1/2" ported unit, please order P3YKA*BCP port block kit SA Auto drain
separately.
Most popular.
10
Seals Nitrile NBR 0.60
2 0.15
0.30
4
2 0.15
0 0
0 10 20 30 40 50 60 70 80 90 100 120 140 160 180 200
Flow - (dm 3/s)
n
6.69
(170)
1.57
(40) 1.97
(50)
9.92 0.39
(252) (10)
8.45
(212)
Inches (mm)
Ordering Information:
P3YFA 9 6 D SC N
Basic Series Thread Type* Port Size Element Drain Type
Coalescing BSPP 1 3/4 6 0.01 micron Combined
P3YFA
Filter NPT 9 1 8 D Element with DPI SC Manual / Semi
Standard Auto Drain
A Adsorber SA Auto Drain
* Note: For 1-1/2" ported unit, please order P3YKA*BCP port block kit
separately.
Most popular.
stainless steel 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300
Support media Polypropylene Flow - (dm 3/s)
n
Anti re-entrainment barrier Polyester 0 100 200 300 400 500 600
Flow - (scfm)
Encapsulation Epoxy resin /
hardener
Seals Nitrile NBR (1") 0.01 Micron Coalescing Filter Saturated
Manual / semi-auto drain Acetal Primary Pressure - bar 2.5 6.3 10
Primary Pressure - psig 36.2 91.4 145
12
Auto drain PA / Ø 10mm 0.75
brass connection 10
0.60
0.30
Differential pressure indicator, spring Stainless steel 4
1.97
(50)
Coalescing
13.38
0.39
(340)
(10)
Adsorber
12.59
(320)
11.22
(285)
Inches (mm)
P3Y Regulators
• Integral 3/4" or 1" ports (BSPP and NPT)
• Robust but lightweight aluminium construction
• Secondary pressure ranges 12 and 16 bar
• Rolling diaphragm for extended life
• Secondary aspiration plus rolling diaphragm provides quick
response and accurate pressure regulation
• Optional tamperproof regulator padlock
• Reverse flow / relieving option
• Low temperature -40°C (-40°F)
3 3
1 2 1 2
Operating Information
Self relieving Reverse flow Non-relieving
regulator with gauge relieving regulator regulator Supply pressure (max)*: 254 psig (17.5 bar)
Operating temperature: -40°F to 140°F (-40°C to 60°C)
Flow capacity :†
3/4" 380 scfm (179.3 dm3/s, ANR)
1" 550 scfm (259.6 dm3/s, ANR)
Port Fluid: Compressed air
Size Description Part Number Gauge port (x2): 1/4"
3/4" 174 psig relieving P3YRA96BNEN Weight: 2.4 lb (1.08 kg)
P3YRA96BNFN Inlet pressure 145 psig (10 bar) inlet pressure, 91.4 psig (6.3 bar) set pressure
†
3/4" 174 psig relieving + pressure gauge
and 7.3 psig (0.5 bar) pressure drop.
1" 174 psig relieving P3YRA98BNEN * Air supply must be dry enough to avoid ice formation at temperatures below
35.6°F (2°C).
1" 174 psig relieving + pressure gauge P3YRA98BNFN
Ordering Information
P3YRA 9 6 B N E N
Basic Series Thread Type* Port Size Relief Lockable Adjustment Range
Regulator P3YRA BSPP 1 3/4 6 B Relieving N Standard 0 to 174 psi (0 to 12 bar), No
E
NPT 9 1 8 Reverse Flow / A† Lockable Gauge
R
Relieving 0 to 232 psi (0 to 16 bar), No
H
Gauge
Notes:
* For 1-1/2" ported unit, please order P3YKA*BCP port block kit separately. F 0 to 174 psi (0 to 12 bar), Gauge
† Not field convertible. J 0 to 232 psi (0 to 16 bar), Gauge
Most popular.
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720
Repair and Service Kits Flow - (scfm)
Product rupture can cause serious injury. 0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720
Do not connect regulator to bottled gas. Flow - (scfm)
Do not exceed Maximum primary pressure rating.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT – The working range of knob
adjustment is designed to permit outlet pressures within their full range.
Pressure adjustment beyond this range is also possible because the knob
is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting.
3.54
(90)
2.17
(55) M64x2
0.39
2.40 3.11
(10)
(61) (79)
5.24 0.35
(133) (9) 2.36 0.32
(60) (5)
7.17 2.74
(182) (69.5)
Inches (mm)
Operating Information
Supply pressure (max): 254 psig (17.5 bar)
Operating temperature: -40°F to 140°F (-40°C to 60°C)
Flow capacity : †
3/4" 550 scfm (259.6 dm3/s, ANR)
1" 550 scfm (259.6 dm3/s, ANR)
Port Fluid: Compressed air
Size Description Part Number
Weight: 2.6 lb (1.2 kg)
3/4" Pilot operated regulator P3YRA96BPPN †
Inlet pressure 145 psig (10 bar) inlet pressure, 91.4 psig (6.3 bar) set pressure
and 7.3 psig (0.5 bar) pressure drop.
1" Pilot operated regulator P3YRA98BPPN
Ordering Information
P3YRA 9 6 BPPN
Basic Series Thread Type* Port Size
Pilot Operated BSPP 1 3/4 6
P3YRA
Regulator NPT 9 1 8
Most popular.
WARNING 0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680 720
Flow - (scfm)
1/8
0.75
(19)
pst
G1/8
3.54
(170)
5.52
(140)
2.40 ~3.11 3.54
(61) (79) (90)
0.35
2.22 (9)
(56.5)
1.95
(49.5)
4.15 1.97
(105.5) (50)
1.93
(49)
0.39
(10)
Inches (mm)
Port
Size Description Part Number
Normally Closed,
3/4" P3YPA96BD2VA2A
0 - 10 bar (0 to 145 psig)
Normally Closed,
1" P3YPA98BD2VA2A
0 - 10 bar (0 to 145 psig)
Operating Information
Operating pressure: P1 min 14.5 psig (1 bar) Power consumption: IBmax 0.15 A
Inlet pressure 1: P1 max 232 psig (16 bar) Set value input: Uw V 0-10
Operating pressure: P2 min 2.9 psig (0.2 bar) I mA 0-20
Outlet pressure P2 max 145 psig (10 bar) mA 4-20
Operating temperature: 32°F to 122°F (0°C to 50°C) Input resistance: Re 243 K Ω
Flow capacity†: 706 scfm (332 dm3/s, ANR) Actual valve output: Ux 0 - 10 V
l/min 20000 Output current: IAmax 10 mA
m3/h 1200
Degree of protection: IP65 to DIN 40050, EN 60529
Hysteresis: P2 max < 1%
Fluid: Compressed air
Repeatability: P2 max < 0.5%
Weight: 1.2 lb (2.7 kg)
Sensitivity: P2 max < 0.5% 1
) p1 > p2 + 10% p2
Linearity: P2 max < 1% 2
) at p1 - 10 bar to p2 - 6.3 bar
Nominal voltage: Un V DC 24 V = ± 10% †
Inlet pressure 91.4 psig (6.3 bar) inlet pressure and 7.3 psig (0.5 bar)
Residual ripple: 10% pressure drop.
Ordering Information
P3YPA 9 6 B D 2 A A 2 A
Basic Series Thread Type* Version Control Signal Input Connector
Proportional Pressure BSPP 1 Side Exhaust, NC B A 4-20 mA 2 M12 (5-pin)
P3YPA
Regulator NPT 9 (Normally closed) V 0-10 V
Side Exhaust, NO C
Port Size (Normally open)
Power Supply Output Signal
3/4 6 2 24 volts A Analog 0-10 V
Pressure Range
1 8
0-10 bar (0-145 psig) D
* Note: For 1-1/2" ported unit, please order
P3YKA*BCP port block kit separately.
Most popular.
Cables 5
8 4
P2 (bar)
Type Part Number 4
8 2
2
Connection Diagram 1
0
5 2000 4000 6000 8000 10000 12000 14000 16000 18000
Q (l/min)
1 4
2 3
Connector M12 x 1
Pin No. Function
1 24 V Supply
2 0V Reference & mass capacity
3 0 - 10 V Set value input
4 0V Signal
5 0 - 10 V Analog output
170
(3.54)
140
(5.52)
Ø 64 Secondary pressure relief 1/8
(Ø 2.52) Exhaust pilot air M5
Max. 14
(.67) M12x1 **
140
(5.52) 40
(1.57)
50 G1
(1.97) (3/4)
49
(1.93)
10
(.39)
90 9 94
(3.54) (.35) (3.70)
2.5
(.10) 61 52
(2.40) (2.05)
Ordering Information
P3YEA 9 6 E SA B N E N
Basic Series Thread Type* Drain Type Relief Lockable Adjustment Range
Filter / BSPP 1 Combined Manual B Relieving N Standard 0 to 174 psi
P3YEA
Regulator NPT 9 Sc / Semi-Auto Reverse Flow A† Lockable E (0 to 12 bar), No
Drain R Gauge
/ Relieving
Port Size Sa Auto Drain 0 to 232 psi
3/4 6 H (0 to 16 bar), No
Notes: Element Gauge
* For 1-1/2" ported unit, please order 1 8
E 5 micron 0 to 174 psi
P3YKA*BCP port block kit separately. F
† Not field convertible. (0 to 12 bar), Gauge
0 to 232 psi
J
(0 to 16 bar), Gauge
Most popular.
120
Control Knob Glass filled 0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680
Flow - (scfm)
polyamide
Valve Brass / NBR
Screws Steel / zinc
plated (1") 5 Micron Filter / Regulator
9.0
Repair and Service Kits 120
0 40 80 120 160 200 240 280 320 360 400 440 480 520 560 600 640 680
Panel mount nut P3YKA00MM Flow - (scfm)
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed Maximum primary pressure rating.
CAUTION: 3.54
(90)
REGULATOR PRESSURE ADJUSTMENT – The working range of knob 2.17
adjustment is designed to permit outlet pressures within their full range. M64x2
(55)
Pressure adjustment beyond this range is also possible because the knob 3.11 0.39
2.40
is not a limiting device. This is a common characteristic of most industrial (61) (79) (10)
regulators, and limiting devices may be obtained only by special design. For
best performance, regulated pressure should always be set by increasing the
pressure up to the desired setting. 0.35
2.36 5.24 (9)
0.32
(60) (5) (133)
2.74
(69.5)
1.34
13.58 (34)
(345)
Gauge
port 1/4 Gauge
8.45 port 1/4
(212)
Inches (mm)
P3Y Lubricator
• Integral 3/4" or 1" ports (BSPP and NPT)
• Robust but lightweight aluminium construction
• Proportional oil delivery over a wide range of air flows
• Possible to fill under system pressure eliminating
down time
• Large oil reservoir
1 2
Lubricator
with drain
Operating Information
Supply pressure (max)*: 254 psig (17.5 bar)
Operating temperature*: 14°F to 140°F (-10°C to 60°C)
Flow capacity†: 3/4" 315 scfm (148.2 dm3/s, ANR)
1" 390 scfm (184.1 dm3/s, ANR)
Port Fluid: Compressed air
Size Description Part Number
Weight: 1.8 lb (0.8 kg)
3/4" Oil Mist, Fill Under Pressure P3YLA96LSNN †
Inlet pressure 91.4 psig (6.3 bar) inlet pressure and 7.3 psig (0.5 bar) pressure
drop.
1" Oil Mist, Fill Under Pressure P3YLA98LSNN
* Air supply must be dry enough to avoid ice formation at temperatures below
35.6°F (2°C).
Low flow start point (lubrication pick-up): at 6.3 bar (91.4 psig) inlet pressure
0.5 dm3/s (1.1 scfm).
Ordering Information
P3YLA 9 6 LSNN
Basic Series Thread Type* Port Size
Lubricator P3YLA BSPP 1 3/4 6
NPT 9 1 8
* Note: For 1-1/2" ported unit, please order P3YKA*BCP port block kit
separately.
Most popular.
2 0.15
0 0
Repair and Service Kits 0 20 40 60 80 100 120 140 160 180
Flow - (dm 3/s)
200 220 240 260 280 300
P3YKA00BSN
n
Bowl kit
0 100 200 300 400 500 600
Refill plug P3YKA00PL Flow - (scfm)
12 0.75
2 0.15
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300
Flow - (dm 3/s)
n
6.69
(170)
2.40 1.57 5.51
(61) (47) (140)
3.54
.098 (90)
(2.5) 0.39
(10)
1.85
(40)
1.97
(55)
9.72 0.35
(247) (9)
7.48
(190)
Inches (mm)
P3Y Combinations
Ordering Information:
P3YCA 9 6 SE C N F LNF
Basic Series Thread Type* Port Size Drain Type Adjustment Range
Filter / Regulator + BSPP 1 3/4 6 Combined Manual / 0-12 bar (0 to 174 psi)
P3YCA C F
Lubricator NPT 9 1 8 Semi-Auto Drain with Gauge
Filter + Regulator + A Auto Drain 0-16 bar (0 to 232 psi)
P3YCB J
Lubricator with Gauge
* Note: For 1-1/2" ported unit, please order P3YKA*BCP port block kit
separately.
WARNING
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed Maximum primary pressure rating.
CAUTION:
REGULATOR PRESSURE ADJUSTMENT –
The working range of knob adjustment is designed to permit outlet pressures within
their full range. Pressure adjustment beyond this range is also possible because
the knob is not a limiting device. This is a common characteristic of most industrial
regulators, and limiting devices may be obtained only by special design. For best
performance, regulated pressure should always be set by increasing the pressure up
to the desired setting.
Most popular.
P3Y Combinations
10.63
(270)
3.54
(90)
2.17
M64x2
(55)
2.40 3.11 0.39
(61) (79) (10)
0.35
2.36 0.32 1.33 (9)
(60) (5) (5.24)
2.74
(69.5)
1.34
13.58 (34)
Gauge (345)
port 1/4
8.45
(212)
7.09
(180)
3.54
(90)
2.17
M64x2
(55)
2.40 3.11 0.39
(61) (79) (10)
0.35
2.36 0.32 5.24 (9)
(60) (5) (133)
2.74
(69.5)
1.34
13.58 (34)
(345) Gauge
Gauge port
port 1/4 1/4
8.45
(212)
6.69
(170)
2.40 1.85 5.51
(61) (47) (140)
0.01 3.54 0.35
(2.5) (90) (9)
1.57
(40) 1.97
(50)
9.92 0.39
(252) 8.45 (10)
(212)
P3Y Series Combined Soft Start / Dump Valves, provide for the
safe introduction of pressure to machines or systems. Soft Start
/ Dump Valves when set, allow the pressure to gradually build
to the set point before fully opening to deliver full flow at line
pressure.
The controlled introduction of pressure can be an important Operating Information
safety factor and prevent damage to tooling when air pressure is Operating pressure (max):
introduced at machine or system start up. 30mm coil 232 psig (16 bar)
Operating pressure (min): 2.9 psig (0.2 bar)
Operating temperature*:
Solenoid operated 14°F to 140°F (-10°C to 60°C)
2 Air pilot operated 14°F to 140°F (-10°C to 60°C)
Air pilot port: 1/8"
Exhaust port: NPT 3/4"
BSPP 1"
3 1 Gauge port: 1/4"
Flow capacity†: 3/4" 371 scfm (175.1 dm3/s, ANR)
Port 1" 424 scfm (200.1 dm3/s, ANR)
Size Description Part Number Fluid: Compressed air
3/4" Air pilot operated P3YTA96PPN Weight: Air pilot 3.1 lb (1.4 kg)
30mm coil 3.5 lb (1.6 kg)
3/4" 24VDC 30mm coil P3YTA96SCNA2CN
1" Air pilot operated P3YTA98PPN
†
Inlet pressure 91.4 psig (6.3 bar) inlet pressure and 7.3 psig (0.5 bar) pressure
drop.
1" 24VDC 30mm coil P3YTA98SCNA2CN * Air supply must be dry enough to avoid ice formation at temperatures
below 35.6°F (2°C).
Snap pressure: Full flow when downstream pressure reaches 50% of the
inlet pressure.
Ordering Information
P3YTA 9 6 P C N A 2 C N
Basic Series Thread Type* Pilot Type Solenoid Voltage
Soft Start / BSPP 1 External Air Pilot P 2CN 24VDC
P3YTA
Dump Valve NPT 9 Solenoid Pilot S
Most popular.
Flow Characteristics
100% 4
Combined start / stop function with acknowledgement
Pressure (p)
90%
1 0%
2
Time (t)
1 Start signal
2 Switching time delay
3 Gradual pressure build up
4 Operating pressure p2 (= p1)
SW3 23
SW3 0.98
(25) Allen key
25
(.98) adjustment
0.98
(25)
25 0.63
1/8 1A (16) 12
(.98)
0.6
15.25 (15.25)
(.6)
3.50
89 (89)
(3.50) Ø 1.18
0.59
(15) (30)
61 17 3/4
(2.40) (.67) (G1)
G1 3.19
(3/4) (81) 2.20
(56)
81
(3.19) 56
(2.20) 1.93
(49)
49 3/4 3.54
(1.93 (G1) (90)
3.70
(94)
G1 90 4.09
(3/4) (3.54) (104)
94
(3.70)
104
(409)
Catalog 0760P For inventory, lead
99 Pneumatic Division | Richland, Michigan
times, and kit lookup,
Air Preparation Products visit www.pdnplu.com www.parker.com/pneumatics
Air Preparation Products
Soft Start Valve P3Y Series
Operating Information
Port Operating pressure (max): 254 psig (17.5 bar)
Size Description Part Number Operating pressure (min): 29 psig (2 bar)
3/4" Soft Start Valve P3YSA96Y0N Operating temperature*:
Solenoid operated 14°F to 140°F (-10°C to 60°C)
1" Soft Start Valve P3YSA98Y0N Air pilot operated 14°F to 140°F (-10°C to 60°C)
Flow capacity †: 3/4" 324 scfm (152.9 dm3/s, ANR)
Material Specifications 1" 324 scfm (152.9 dm3/s, ANR)
Fluid: Compressed air
Body Aluminium
Weight: 1.8 lb (0.8 kg)
Body cover ABS
†
Inlet pressure 91.4 psig (6.3 bar) inlet pressure and 7.3 psig (0.5 bar) pressure
Valve Brass / NBR drop.
composite * Air supply must be dry enough to avoid ice formation at temperatures
below 35.6°F (2°C).
Pilot valve booster Aluminum
Snap pressure: Full flow when downstream pressure reaches 50% of the
Seals Nitrile NBR inlet pressure.
Ordering Information
P3YSA 9 6 Y 0 N
Basic Series Thread Type* Port Size
Soft Start Valve P3YSA BSPP 1 3/4 6
NPT 9 1 8
* Note: For 1-1/2" ported unit, please order
P3YKA*BCP port block kit separately.
Flow Characteristics
4 1.97 1.85
100%
(50) (47)
SW3
Pressure (p)
34
90% (1.34)
3
51
1 0% (2.01)
2
Most popular.
Ordering Information
P3YVA 9 6 LBN
Basic Series Thread Type* Port Size
Modular Ball Valve P3YVA BSPP 1 3/4 6
NPT 9 1 8
* Note: For 1-1/2" ported unit, please order
P3YKA*BCP port block kit separately.
3.15
Material Specifications (80)
Body Aluminium
Valve ball Brass / nickle
plated 3.54
(90)
Handle Aluminum
Seals Nitrile NBR
Exhaust silencer Sintered 0.35
bronze (9)
Ø 1.73 3.54
(44) (90)
0.40
(10.2)
3.19
(81) 2.34
5.31 (59.2)
(135)
3/4 2.60
(G1) (66)
Ø 2.74
(69.5)
1/4
NPT
2.60
(66)
Inches (mm)
3.15
(80)
1/4"
1" 3/4"
Material Specifications
Body Aluminium
Weight 0.65 kg (1.43 lb)
45
(1.77)
Ordering Information
P3YKA 9 B CP Ø 69.5
(Ø 2.74)
Inches (mm)
Working media All neutral media such as compressed air Armature tube: Brass
* Limited to 50°C if use with 100% duty cycle Plunger & core: Corrosion resistant Cr-Ni steel
Seals: Fluorocarbon
Screws: Stainless steel
Most popular.
1.61 1.89
1.77 (41) 1.30 (48)
(45) 1.22 (33)
1.42 1.22 PS243079BP PS203279BP
(36) (31)
(31)
PS2430J79BP PS2032J79CP
0.87 0.87
PS243083BP PS203283BP
2.01 (22) 2.05 (22)
2.36 (51) 2.36 (52) PS2430J83BP PS2032J83CP
(60) (60)
PS294679BP PS294683BP
PS2946J79BP PS2946J83BP
PS2429BP PS2028BP
1.57
(40)
1.22
(31)
1.18
(30)
1.65
(42)
1.87
0.22 1.22 (47.5)
(5.5) (31)
0.82 1.18
(20.8) (30) 1.26
(32)
M3 1.22 0.50
(31) (5)
Most popular.
Weight
Description Connection lb (kg) Part Number
0.01 micron Element Kit P3YKA00ESC
0.11
P3y Connecting Kit P3YKA00CB
(0.05)
1.54
Panel Mounting Nut (Aluminium) P3YKA00MM
(0.70)
0.44
Wall Mounting Brackets P3YKA00CW
(0.2)
Most popular.
1. GENERAL INSTRUCTIONS
1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division
Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components.
1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all
systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons
or property.
1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see:
ISO 4414:1998, Pneumatic Fluid Power – General Rules Relating to Systems. See www.iso.org for ordering information.
1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs
or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this
safety guide as well as the specific Parker publications for the products considered or selected.
1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker
and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use
system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through
its own analysis and testing, is solely responsible for:
• Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory.
• Assuring that all user’s performance, endurance, maintenance, safety, and warning requirements are met and that the application
presents no health or safety hazards.
• Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which
the valves, FRLs or Vacuum products are used; and,
• Assuring compliance with all applicable government and industry standards.
1.6. Safety Devices: Safety devices should not be removed, or defeated.
1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured.
1.8. Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional
information. See the Parker publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com,
for telephone numbers of the appropriate technical service department.
2. PRODUCT SELECTION INSTRUCTIONS
2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system.
System components need to be able to provide adequate flow and pressure for the desired application.
2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the
instruction sheets supplied for maximum pressure ratings.
2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product
and result in complete product failure.
2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic
Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual
circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to
premature failure of a product.
2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of
synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the
factory or product literature for materials of construction.
2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures:
• Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or
temperatures outside of the rated range.
• Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols.
• Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as
phosphate ester and di-ester lubricants.
For inventory, lead
Catalog 0760P 106 Pneumatic Division | Richland, Michigan
times, and kit lookup,
Air Preparation Products visit www.pdnplu.com www.parker.com/pneumatics
Air Preparation Products
Parker Pneumatic Safety Guide
2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins
Tec-3, Tec-4, and Tec-5
2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage.
• Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders.
• Do not exceed the maximum primary pressure rating of any pressure regulator or any system component.
• Consult product labeling or product literature for pressure rating limitations.
3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS
3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be
performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any
signs of nonconformance.
3.2. Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and
vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at
www.parker.com.
3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient
temperature can drop below freezing
4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS
4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced
without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience
with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or
replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must
be established and followed by the user and, at minimum, must include instructions 4.2 through 4.9.
4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate
Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and
Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing
the Parker web site at www.parker.com.
4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more
information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout)
4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged
components:
• Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an
indication of worn or damaged components.
• Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation.
• Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior.
• Any observed improper system or component function: Immediately shut down the system and correct malfunction.
• Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations.
Caution: Leak detection solutions should be rinsed off after use.
4.5. Routine Maintenance Issues:
• Remove excessive dirt, grime and clutter from work areas.
• Make sure all required guards and shields are in place.
4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate
properly and safely.
4.7. Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum
products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly
accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals
need to be established based on:
• Previous performance experiences.
• Government and / or industrial standards.
• When failures could result in unacceptable down time, equipment damage or personal injury risk.
4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal
injury and property damage:
• Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout
Tagout procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout).
• Disconnect electrical supply (when necessary) before installation, servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service,
or conversion.
• Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested
for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or
system into use.
• Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local
representative for replacement labels.
4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions
supplied with the valve FRL or vacuum component to insure proper function of the system.
09/22
Also, Seller shall not be responsible for any loss or damage to Buyer’s financial distress, insolvency, bankruptcy, or other similar conditions affecting
Property while it is in Seller's possession or control. one of the parties, affiliates and/or subcontractors. An event of force majeure
10. Special Tooling. Seller may impose a tooling charge for any Special in the meaning of these Terms means any circumstances beyond Seller’s
Tooling. Special Tooling shall be and remain Seller's property. In no event will control that permanently or temporarily hinders performance, even where that
Buyer acquire any interest in the Special Tooling, even if such Special Tooling circumstance was already foreseen. Buyer shall not be entitled to cancel any
has been specially converted or adapted for manufacture of Goods for Buyer orders following its claim of an event of force majeure.
and notwithstanding any charges paid by Buyer. Unless otherwise agreed, 17. Waiver and Severability. Failure to enforce any provision of these
Seller has the right to alter, discard or otherwise dispose of any Special Terms will not invalidate that provision; nor will any such failure prejudice
Tooling or other property owned by Seller in its sole determination at any time. either party’s right to enforce that provision in the future. Invalidation of any
11. Security Interest. To secure payment of all sums due from Buyer, provision of these Terms shall not invalidate any other provision herein and,
Seller retains a security interest in all Products delivered to Buyer and, Buyer’s the remaining provisions will remain in full force and effect.
acceptance of these Terms is deemed to be a Security Agreement under the 18. Duration. Unless otherwise stated in the Quote, any agreement
Uniform Commercial Code. Buyer authorizes Seller as its attorney to execute governed by or arising from these Terms shall: (a) be for an initial duration of
and file on Buyer's behalf all documents Seller deems necessary to perfect one (1) year; and (b) shall automatically renew for successive one-year terms
Seller’s security interest. unless terminated by Buyer with at least 180-days written notice to Seller or if
12. User Responsibility. Buyer, through its own analysis and testing, is Seller terminates the agreement pursuant to Section 19 of these Terms.
solely responsible for making the final selection of the Products and assuring 19. Termination. Seller may, without liability to Buyer, terminate any
that all performance, endurance, maintenance, safety and warning agreement governed by or arising from these Terms for any reason and at any
requirements of the application of the Products are met. Buyer must analyze time by giving Buyer thirty (30) days prior written notice. Seller may
all aspects of the application and follow applicable industry standards, immediately terminate, in writing, if Buyer: (a) breaches any provision of these
specifications, and any technical information provided with the Quote or the Terms, (b) becomes or is deemed insolvent, (c) appoints or has appointed a
Products, such as Seller’s instructions, guides and specifications. If Seller trustee, receiver or custodian for all or any part of Buyer’s property,(d) files a
provides options of or for Products based upon data or specifications provided petition for relief in bankruptcy on its own behalf, or one is filed against
by Buyer, Buyer is responsible for determining that such data and Buyer by a third party, (e) makes an assignment for the benefit of creditors;
specifications are suitable and sufficient for all applications and reasonably or (f) dissolves its business or liquidates all or a majority of its assets.
foreseeable uses of the Products. In the event Buyer is not the end-user of the 20. Ownership of Rights. Buyer agrees that (a) Seller (and/or its affiliates)
Products, Buyer will ensure such end-user complies with this paragraph. owns or is the valid licensee of Seller’s IP and (b) the furnishing of information,
13. Use of Products, Indemnity by Buyer. Buyer shall comply with all related documents or other materials by Seller to Buyer does not grant or
instructions, guides and specifications provided by Seller with the Quote or the transfer any ownership interest or license in or to Seller’s IP to Buyer, unless
Products. If Buyer uses or resells the Products in any way prohibited by expressly agreed in writing. Without limiting the foregoing, Seller retains
Seller’s instructions, guides or specifications, or Buyer otherwise fails to ownership of all Software supplied to Buyer. In no event shall Buyer obtain
comply with Seller’s instructions, guides and specifications, Buyer any greater right in and to the Software than a right in a license limited to the
acknowledges that any such use, resale, or non-compliance is at Buyer's sole use thereof and subject to compliance with any other terms provided with the
risk. Further, Buyer shall indemnify, defend, and hold Seller harmless from any Software. Buyer further agrees that it will not, directly or through
losses, claims, liabilities, damages, lawsuits, judgments and costs (including intermediaries, reverse engineer, decompile, or disassemble any Software
attorney fees and defense costs), whether for personal injury, property (including firmware) comprising or contained within a Product, except and only
damage, intellectual property infringement or any other claim, arising out of or to the extent that such activity may be expressly permitted, either by
in connection with: (a) improper selection, design, specification, application, or applicable law or, in the case of open source software, the applicable open
any misuse of Products; (b) any act or omission, negligent or otherwise, of source license.
Buyer; (c) Seller’s use of Buyer’s Property; (d) damage to the Products from 21. Indemnity for Infringement of Intellectual Property Rights. Seller
an external cause, repair or attempted repair by anyone other than Seller, is not liable for infringement of any Intellectual Property Rights except as
failure to follow instructions, guides and specifications provided by Seller, use provided in this Section. Seller will defend at its expense and will pay the cost
with goods not provided by Seller, or opening, modifying, deconstructing, of any settlement or damages awarded in an action brought against Buyer
tampering with or repackaging the Products; or (e) Buyer’s failure to comply based on a third-party claim that one or more of the Products infringes the
with these Terms, including any legal or administrative proceedings, collection Intellectual Property Rights of a third party in the country of delivery of the
efforts, or other actions arising from or relating to such failure to comply. Seller Products by Seller to Buyer. Seller's obligation to defend and indemnify Buyer
shall not indemnify Buyer under any circumstance except as otherwise is contingent on Buyer notifying Seller within ten (10) days after Buyer
provided in these Terms. becomes aware of any such claim, and Seller having sole control over the
14. Cancellations and Changes. Buyer may not cancel or modify, defense of the claim including all negotiations for settlement or compromise. If
including but not limited to movement of delivery dates for the Products, any one or more Products is subject to such a claim, Seller may, at its sole
order for any reason except with Seller's written consent and upon terms that expense and option, procure for Buyer the right to continue using the
will indemnify, defend and hold Seller harmless against all direct, incidental Products, replace or modify the Products to render them non-infringing, or
and consequential loss or damage and any additional expense. Seller, at any offer to accept return of the Products and refund the purchase price less a
time, may change features, specifications, designs and availability of reasonable allowance for depreciation. Seller has no obligation or liability for
Products. any claim of infringement: (i) arising from information provided by Buyer
(including Seller’s use of Buyer’s Property); or (ii) directed to any Products for
15. Assignment. Buyer may not assign its rights or obligations without the
which the designs are specified in whole or part by Buyer; or (iii) resulting from
prior written consent of Seller.
the modification, combination or use in a system of any Products. The
16. Force Majeure. Seller is not liable for delay or failure to perform any of its foregoing provisions of this Section constitute Seller's sole and exclusive
obligations by reason of any events or circumstances beyond its reasonable liability and Buyer's sole and exclusive remedy for claims of infringement of
control. Such circumstances include without limitation: accidents, labor Intellectual Property Rights.
disputes or stoppages, government acts or orders, acts of nature, pandemics,
22. Governing Law. These Terms, the terms of any Quote, and the sale and
epidemics, other widespread illness, or public health emergency, cyber related
delivery of all Products are deemed to have taken place in, and shall be
disruptions, cyber-attacks, ransomware sabotage, delays or failures in delivery
governed and construed in accordance with, the laws of the State of Ohio, as
from carriers or suppliers, shortages of materials, sudden increases in the
applicable to contracts executed and wholly performed therein and without
price of raw material or components, shutdowns or slowdowns affecting the
regard to conflicts of laws principles. Buyer irrevocably agrees and consents to
supply of raw materials or components, or the transportation thereof, oil
the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio
shortages or oil price increases, energy crisis, energy or fuel interruption, war
with respect to any dispute, controversy or claim arising out of or relating to
(whether declared or not) or the serious threat of same, riots, rebellions, acts
the sale and delivery of the Products.
of terrorism, embargoes, fire or any reason whether similar to the foregoing or
otherwise. Seller will resume performance as soon as practicable after the 23. Entire Agreement. These Terms, along with the terms set forth in the
event of force majeure has been removed. All delivery dates affected by an Quote, forms the entire agreement between the Buyer and Seller and
event of force majeure shall be tolled for the duration of such event of force constitutes the final, complete and exclusive expression of the terms of sale
majeure and rescheduled for mutually agreed dates as soon as practicable and purchase. In the event of a conflict between any term set forth in the
after the event of force majeure ceases to exist. The right to allocate capacity Quote and these Terms, the terms set forth in the Quote shall prevail. All
is in the Seller’s sole discretion. An event of force majeure shall not include prior or contemporaneous written or oral agreements or negotiations with
09/22
respect to the subject matter shall have no effect. No modification to these
Terms will be binding on Seller unless agreed to in a writing that is signed
by an authorized representative of Seller, excluding email correspondence,
'clickwrap' or other purported electronic assent to different or additional
terms. Sections 2-25 of these Terms shall survive termination or
cancellation of any agreement governed by or arising from these Terms.
24. No ‘Wrap’ Agreements/No Authority to Bind. Seller’s clicking any
buttons or any similar action, such as clicking “I Agree” or “Confirm,” to utilize
Buyer’s software or webpage for the placement of orders, is NOT an
agreement to Buyer’s Terms and Conditions. NO EMPLOYEE, AGENT OR
REPRESENTATIVE OF SELLER HAS THE AUTHORITY TO BIND SELLER
BY THE ACT OF CLICKING ANY BUTTON OR SIMILAR ACTION ON
BUYER’S WEBSITE OR PORTAL.
25. Compliance with Laws. Buyer agrees to comply with all applicable
laws, regulations, and industry and professional standards, including those of
the United States of America, and the country or countries in which Buyer may
operate, including without limitation the U.S. Foreign Corrupt Practices Act
(“FCPA”), the U.S. Anti-Kickback Act (“Anti-Kickback Act”), U.S. and E.U.
export control and sanctions laws (“Export Laws”), the U.S. Food Drug and
Cosmetic Act (“FDCA”), and the rules and regulations promulgated by the U.S.
Food and Drug Administration (“FDA”), each as currently amended. Buyer
agrees to indemnify, defend, and hold harmless Seller from the consequences
of any violation of such laws, regulations and standards by Buyer, its
employees or agents. Buyer represents that it is familiar with all applicable
provisions of the FCPA, the Anti-Kickback Act, Export Laws, the FDCA and
the FDA and certifies that Buyer will adhere to the requirements thereof and
not take any action that would make Seller violate such requirements. Buyer
represents and agrees that Buyer will not make any payment or give anything
of value, directly or indirectly, to any governmental official, foreign political
party or official thereof, candidate for foreign political office, or commercial
entity or person, for any improper purpose, including the purpose of
influencing such person to purchase Products or otherwise benefit the
business of Seller. Buyer further represents and agrees that it will not receive,
use, service, transfer or ship any Products from Seller in a manner or for a
purpose that violates Export Laws or would cause Seller to be in violation of
Export Laws. Buyer agrees to promptly and reliably provide Seller all
requested information or documents, including end-user statements and other
written assurances, concerning Buyer’s ongoing compliance with Export Law.
09/22
Parker Hannifin Corporation
Pneumatic Division
8676 E. M89
Richland, MI 49083 USA
phone 269 629 5000