OPERATING INSTRUCTIONS
F58S REV. 1
Hall Effect Zero Speed Sensor
F58S
Product ID
Type # Product # Drawing #
F58S 385Z-05332 113.626 Rev.2
General
Function The F58S series Hall effect speed sensors are suitable, in conjunction with a
ferrous pole wheel, for generating square wave signals proportional to rotary
speeds. They exhibit a static function, whereby pulse generation down to 0 Hz is
guaranteed. The sensor function is independent of rotational mounting angle.
Technical data
Supply voltage 8...25 VDC
Current consumption Max. 12 mA (without load)
Signal output Square wave signal from NPN output transistor with internal 2.7 kOhm pull-up
resistor, DC-coupled to supply (negative pole = reference Voltage).
• Sink current: max. 25 mA
• Output voltage:
• Uhigh ~ supply voltage
• Ulow < 0.5 V at I = 25 mA
Frequency range 0 Hz…15 kHz
Housing 5/8"-18 UNF-2A, tightening torque: max. 35 Nm
Connection Cable with open leads:
3-wire, 3 x 0.34 mm2 (AWG22), stranded wires, elastomer isolation, green
casing, fire retardant, low smoke, RoHS conform and halogen free, max. outer Ø
= 4.8 mm, min. bending radius = 25 mm (static) and 50 mm (dynamic), cable
length according to dimensional drawing
Protection Sensor head: IP68
Cable outlet: IP67
Insulation Housing and electronics galvanically isolated (Test: 500 V, 50 Hz for 1 minute)
Pole wheel Prerequisite: Toothed wheel of a ferrous material (e.g. Steel 1.0036).
Optimal performance with
• Involute gear
• Tooth width > 10 mm
• Side offset < 0.2 mm
• Eccentricity < 0.2 mm
Air gap between sensor and • Module 1.0 (DP 25.4): 0.3…0.5 mm
pole wheel • Module 2.0 (DP 12.7): 0.3…1.5 mm
Electromagnetic compatibility Please contact Jaquet for further details.
(EMC)
Vibration & shock immunity Jaquet Greenline sensors are approved for rough environments. Please contact
Jaquet for further details.
Operating temperature -40°C…125°C
www.jaquet.com info@jaquet.com Tel.: +41 61 306 88 22 Page 1/3
OPERATING INSTRUCTIONS
F58S REV. 1
Further Information
Safety All mechanical installations must be carried out by an expert. General safety
requirements have to be met.
Installation The sensor has to be aligned to the pole wheel according to the sensor drawing
independent of its rotational orientation. Deviations in positioning may affect the
performance and decrease the noise immunity of the sensor. During installation,
the smallest possible pole wheel to sensor gap should be set. The gap should
however be set to prevent the face of the sensor ever touching the pole wheel.
Within the air gap specified the amplitude of the output signal is not influenced
by the air gap.
A sensor should be mounted with the middle of the face side over the middle of
the pole wheel. Dependent upon the wheel width, a certain degree of axial
movement is permissible. However, the middle of the sensor must be at
minimum in a distance of 3 mm from the edge of the pole wheel under all
operating conditions.
A solid and vibration free mounting of the sensor is important. Eventual sensor
vibration relative to the pole wheel can induce additional output pulses.
The sensors are insensitive to oil, grease etc. and can be installed in arduous
conditions.
Maintenance Product cannot be repaired.
Transport Product must be handled with care to prevent damage of the front face.
Storage Product must be stored in dry conditions. The storage temperature corresponds
to the operation temperature.
Disposal Product must be disposed of properly, it must not be disposed as domestic
waste.
www.jaquet.com info@jaquet.com Tel.: +41 61 306 88 22 Page 2/3
OPERATING INSTRUCTIONS
F58S REV. 1
www.jaquet.com info@jaquet.com Tel.: +41 61 306 88 22 Page 3/3