GENERAL NOTES 2ND FLR

1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE


PROVISION OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC),

Y
THE RULES AND REGULATIONS OF LOCAL AND NATIONAL AUTHORITIES
CONCERNED WITH ENFORCEMENT OF RULES AND REGULATIONS OF LOCAL

L
UTILITY COMPANY.
GRND FLR.

2. THE SERVICE VOLTAGE TO THE BUILDING SHALL BE SINGLE PHASE, THREE WIRE

N
230 VOLTS, 60 HERTZ SYSTEM. POWER
1 ONE-LINE DIAGRAM

O
3. THE INSTALLATION SHALL BE DONE AS FOLLOWS :
a.) INTERMEDIATE METAL CONDUIT (IMC) ----- EXPOSED CONDUITS EE-1 SCALE NTS
-
b.) POLYVINYL CHLORIDE (PVC) ----- LIGHTING, POWER BRANCH
CIRCUITS, AND AUXILIARY

S
LAYOUT (EMBEDDED IN CONCRETE)
4. ALL WIRES TO BE USED SHALL BE COPPER AND THERMOPLASTIC HEAT

E
INSULATED TYPE "THHN' UNLESS NOTED OTHERWISE SPECIFIED.

S
5. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE APPROVED TYPE
FOR THE LOCATION AND PURPOSED INTENDED.

O
2ND FLR
6. THE MINIMUM SIZE OF WIRE AND CONDUIT TO BE USED SHALL BE 3.5 mm THHN
AND 20 MM DIA. RESPECTIVELY.

P
7. WHENEVER NECESSARY PULL BOX SHALL BE PROVIDED EVEN NOT INDICATED IN
THE PLAN.

R
GRND FLR.
8. BRANCH CIRCUIT HOMERUNS SHALL NOT BE COMBINED IN THE SAME RACEWAY

U
AND RACEWAY FOR AUXILIARY LINES SHALL NOT CONTAINS POWER LINES.
FIBER TO THE HOME
9. MOUNTING HEIGHTS SHALL BE AS FOLLOWS : 2 ONE-LINE DIAGRAM

P
a.) 0.30m ABOVE FLOOR FINISH ----- C.O. OUTLET & AUX. OUTLET
b.) 1.40m ABOVE FLOOR FINISH ----- LIGHT CONTROL SWITCH EE-1 SCALE NTS
-
c.) 1.70m ABOVE FLOOR FINISH @ CENTER ----- PANELBOARDS

L
d.) ALL OTHER HEIGHTS ----- VERIFY TO THE ARCHITECT
SHORT CIRCUIT CALCULATION

A
10.) ALL SERVICE ENTRANCE EQUIPMENTS SUCH AS PANELBOARD SHALL BE
PROPERLY GROUNDED IN ACCORDANCE WITH THE PROVISION OF THE PHILIPPINE
ELECTRICAL CODE.

N
11.) ALL ELECTRICAL WORKS AND INSTALLATIONS HEREIN SHALL BE DONE UNDER LOAD SCHEDULE

DATE:_____________
THE DIRECT SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER

O
OR MASTER ELECTRICIAN.

I
ELECTRICAL SYSTEM LEGEND:

AT
U C
E D
O R

FOR PERMIT
F PROJECT TITLE / LOCATION ARCHITECT ENGINEER
These drawings shall be read in
conjunction with structural,
electrical, mechanical, plumbing/
OWNER

RUBIE ANN F. ILOCTO


SHEET CONTENTS
AS SHOWN
NO.
- -
DATE REVISIONS
-
REVIEWED BY
- -
SHEET NO.

PROPOSED TWO STOREY sanitary and fire protection


-
- -
ARJEE LOUIE DC. JIMENEZ -
ILOCTO RESIDENCE engineering drawings.
The Architect shall be notified of
any discrepancy found and shall
CONTRACTOR
-
- - -
EE-1
4570A SAMPALOC ST. SANTOLAN ROAD. PTR NO.: 1376662 DATE: 01/03/20 PTR NO.: - DATE: - be resolved prior to construction JOVETTAN CONSTRUCTION DRAWN BY: J-A CHECKED BY: -
GEN. T. DE LEON VAL CITY REG NO.: 38508 TIN: 317-654-695 REG NO.: - TIN: - DATE DRAWN: AUG 2020 DATE CHECKED: AUG 2020 - - -
- -