Sim ult aneously 12 leadsAcquisi tion
E10
Digital Three Channel ECG Machine
Overview Environmental Conditions:
A/D shift: 24 bits
Simultaneously 12 Leads Acquisition Transportation Temperature:-20℃~+55℃
Sampling rate : 32000Hz (1ms)
5 Inch 854*480 HD LED Screen with Relative Humidity:10%~95%
Sensitivity: 20mm/mV、10mm/mV、
Standard Grid Background
5mm/mV Auto Atmospheric Pressure: 50kpa ~106kpa
Built-in print layout: Paper Speed: 12.5, 25, 50mm/s Operation Temperature:+5℃~+40℃
3x4, 3x4+1,
Recording Mode: Thermal array printer 8 Relative Humidity:20%~85%(no
Sampling Modes: dot/ mm (Vertical) condensation)
Real-time/Pre-sampling mode 40 dot/ mm (Horizontal,
25mm/s) Atmospheric Pressure:57kPa~106kPa
Manual/Auto/Rhythm Modes
Storage Temperature:-20℃-+55℃
Support Multiple Languages: Paper Type: Roll Paper
Simplified Chinese, English, Russian, Paper Size: 80mm/20m
French, Spanish, Filter Setting:
AC: off/50/60Hz;
Format Report Storage: System Inputs & Outputs
ZQECG、PDF、PNG、JPG、XML EMG: off/25/35/45/75/100/150Hz;
USB
Alarm: DFT: off/0.01/0.05/0.3/0.6Hz
Electrode Disconnection
Standard Package
Three colors to indicate levels of
E10 ECG Machine (with battery)
waveform quality
Patient Cable
Recorder Unavailable Physical Specification
Chest Electrodes
Support connect to the workstation Dimension & weight:
Limb Electrodes
Built-in Protection against Defibrillator Equipment:264mm×180mm×64.5mm
Thermal Printing Paper
Support PACE Detection about 1 kg Power Cord
Heart Rate Detection Range: 30-300 Package: 335mm*182mm*265mm; 3.1kg User Manual
Rhythm analysis : 1 minutes Electrical Power: Paper Roller
AC: 100V-240V, 50Hz/60Hz, 30VA
Technique Specification DC: Built-in Lithium Battery
Frequency Response: 0.01 ~ 350Hz Battery Capacity: Optional Accessories
3.7V/5200mAh Series Electrodes
Time Constant: ≥ 3.2s
Continuous Operating: Thermal Printing Paper
Resolution : 800*480
AC ≥ 5h Lithium Battery
Time Constant: ≥ 3.2s
Recharge time: Workstation Software
CMRR: ≥ 120dB
The battery is charged to 90% for no more Trolley
Patient Leakage Current: ≤10µA
than 3 hours, and charged to 100% for no Paper Roller
Calibration Voltage : 1mV ± 2% Suitcase
more than 3.5 hours
Input Circuit: ≤ 50μA
Data Storage:
Input Impedance: ≥ 60 MΩ(10 Hz)
Max. 5000 sets; support USB
Noise Level: ≤ 15μVp∽p
Sensitivity valve: 20 μV
Polarization Voltage: ±850mV
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: 380,HIGH-TECH 2ND ROAD, EASTLAKE HIGH-TECH DEVELOPMENT, ZONE,WUHAN, HUBEI 430206, CHINA
Tel: +86-27-87770203 Email: info@zoncare.com
Fax: +86-27-87770581 Website: www.zoncare.com/en/
Wuhan Zoncare Bio-Medical Electronics Co., Ltd.
Add: 380,HIGH-TECH 2ND ROAD, EASTLAKE HIGH-TECH DEVELOPMENT, ZONE,WUHAN, HUBEI 430206, CHINA
Tel: +86-27-87770203 Email: info@zoncare.com
Fax: +86-27-87770581 Website: www.zoncare.com/en/