CURRENT TRANSFORMERS
f edge o ing e cutt control At th rrent cu
t oun al M tion ket Op c Bra in B mm mm
in A
INDEX
Contents
Series CGCT, Enclosed Measurement CTs Series CGECT, Enclosed Measurement CTs Series CGCTP, Tape Wound Measurement CTs Series CGPRO, Tape Wound Protection CTs
Page
1
Series IC, 9 Resin Cast Measurement and Protection CTs
The Current Transformers (CTs) are designed for ease of mounting and access, as well as to minimise space requirements. The standard frames, which include overlapping current ratios, permit selection for any cable or busbar system. Enclosed, Tape Wound and Resin Cast Measurement CTs and Tape Wound and Resin Cast Protection CTs for DIN Rail, Busbar and Bracket Mounting are offered but CTs beyond the range specified in this catalogue, also can be offered on request.
SERIES CGCT, ENCLOSED MEASUREMENT CTS
MEASUREMENT CTS Measurement CTs are required to transform the primary current, at various classes of accuracy, as specified by the class designation, over a current range from 5% to 120% of its rated primary current. The design of this type of CT requires the inclusion of a core and winding which will, when connected to its rated burden, perform within the limits of error as indicated by the standards specifications. It is an advantage for a measurement CT to saturate above this range, which provides a protection against damage to instrument by limiting the secondary current, when surge current or faults appear in the primary circuit.
10 % INCREMENT Protection CT 50% INCREMENT
manufacturers allowing the CT to be mounted at any location with ease. The DIN rail mounting and other mounting and cabling features make the CGCTs the most versatile Current Transformer range. FEATURES Series CGCT CTs are certified for the following marks.
Clips are provided for foot mounting as standard for all sizes. Busbar Clamps are provided as standard accessories from size CGCT-3 onwards. APPLICATIONS Series CGCT CTs measure currents from 30 Amps to 4000 Amps. Their accuracy allows operation within the range of 5% to 120% of the primary current. This accuracy depends on the load connected to the secondary of the CTs, which includes both the impedance of the connected measuring instruments and connecting cables. The CTs can be mounted in direct contact with the busbars operating at a maximum temperature of 105C. They can withstand, without damage, the high temperatures that can occur in enclosed switchboards. SPECIFICATIONS Designed to comply with BS 7626, 1993 and IEC 44, 1996 (earlier IEC 185, 1987) Can operate at temperature ranges from - 20 Deg C up to +70 Deg C ambient. Di-electric strength of 2.50 kV for one minute. Nominal frequency 50/60 Hz. Rated voltage 660V AC max. Short circuit thermal current (Ith) - 60 times rated primary current for one sec. Rated dynamic current (I Dyn) 2.5 Times Ith Degree of protection IP40
1
KNEEPOINT
Measurement CT
EXCITING CURRENT
Typical Magnetising Characteristics of CTs indicating the comparison between Measurement & Protection CTs.
SERIES CGCT, ENCLOSED CURRENT TRANSFORMERS The Series CGCT CTs, i.e. CGCT1, CGCT-2 and CGCT-3, from 30/5 Amps to 1200/5 Amps are provided with unique feature of DIN rail mounting facility at the base of the CTs for mounting on DIN35 rails. This feature is a boon to panel
Enclosure is made of high Impact flame resistant ABS. Terminal cover is clear acrylic for easy visibility. Also sealing arrangement is provided as a standard feature in all sizes. Terminals are shrouded when cover is removed and knockouts are provided in the shroud to allow selection of cable entry direction. Pleasing blue colour. Cost effective, economical design. Primary currents from 30 Amps to 4000 Amps. Secondary currents 1 Amp and 5 Amps Available in six frame sizes CGCT-1 to CGCT-6 and accuracy classes of 0.5, 1, 3 and 5. Option of Terminal Connections - Direct, Cable Clamp or Cable lug. Option of mounting arrangements - DIN rail mounting on DIN35 rail, on feet, on bottom and sides, panel and bulkhead.
SECONDARY VOLTAGE
SERIES CGCT, ENCLOSED MEASUREMENT CTS
ALTERNATE ARRANGEMENTS OF CTS AND BUSBARS
A A B
C
BUSBAR MOUNTING DATA
MINIMUM PHASE CENTRES, MM TYPE CURRENT RANGE, AMPS MAXIMUM BUSBAR SIZE MMS 6.3 20 6.3 31.5 11.5 50 18.9 80 25.2 80 12.6 100 31.5 125 TYPICAL BUSBAR RATING, AMPS 300 450 1200 2300 2700 1900 4100 SIDE BY SIDE CTS A 66 66 99 127 150 150 195 OVERLAPPING CTS B HORIZONTAL 45 50 75 105 115 126 161 C VERTICAL 38 38 57 78 96 88 128
CGCT - 1 CGCT - 2 CGCT - 3 CGCT - 4 CGCT - 5 CGCT - 6
30 75
- 150 - 400
300 - 1200 600 - 2000 1200 - 2500 1600 - 4000
DIMENSIONS
CGCT - 1 CGCT - 2 CGCT - 3
97
95
56
78
78
56
39.5
39.5
33
50. 5
12
74
74
51 84.5
CGCT - 4
CGCT - 5
147 105
CGCT - 6
191 127.5
127
21
85.5
120
22
95
8 4
162
150
134
180
205 195
8 2
74
82
65.5
81
26
1 8
32
115.5
45 81.5 136
57 180
All dimensions are in mm.
99
SERIES CGCT, ENCLOSED MEASUREMENT CTS
RATIO
VA 2 30/5 A 40/5 A 50/5 A 60/5 A 75/5 A 100/5 A 150/5A
CLASS 5
3 4 5 7.5 2
CLASS 3
3 4 5 7.5 3
CLASS 1
5
CGCT - 1
RATIO
VA 2
CLASS 5
5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2 3
CLASS 0.5
5 7.5 10 15
CGCT - 2
75/5 A 100/5 A 150/5 A 200/5 A 300/5 A 400/5 A
RATIO
VA 2 300/5 A 400/5 A 500/5 A 600/5 A 800/5 A 1000/5 A 1200/5 A
CLASS 5
5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2 5
CLASS 0.5
7.5 10 15
CGCT - 3
RATIO
VA 2
CLASS 5
5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2 5
CLASS 0.5
7.5 10 15
CGCT - 4
600/5 A 800/5 A 1000/5 A 1200/5 A 1600/5 A 2000/5 A
RATIO
CLASS 5
2 5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2 5
CLASS 0.5
7.5 10 15
CGCT - 5
VA 1200/5 A 1600/5 A 2000/5 A 2500/5 A
RATIO
CLASS 5
2 5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2 5
CLASS 0.5
7.5 10 15
CGCT - 6
VA 1600/5 A 2000/5 A 2500/5 A 3000/5 A 4000/5 A
NOTE: The shaded squares indicate the range upto which the CTs can perform.
All dimensions are in mm
SERIES CGCT, ENCLOSED MEASUREMENT CTS
CONNECTIONS AND MOUNTING VARIATIONS
CLEAR ACRYLIC COVER HELD SECURELY BY SCREW, CAN BE SEALED
CABLE TERMINATION WITH CABLE LUG
BULK HEAD MOUNTING WITH CAPTIVE NUTS (SCREWS PROVIDED)
DIN RAIL MOUNTING ARRANGEMENT
FOOT MOUNTING USING CLIPS
TYPE CGCT - 1 CGCT - 2 CGCT - 3 CGCT - 4 CGCT - 5 CGCT - 6
S 53 mm 53 mm 62 mm 74 mm 92 mm 130 mm
42
71 60
BUSBAR CLAMP ARRANGEMENT (CLAMPS PROVIDED)
S
MOUNTING FEET
VA BURDEN GUIDE
Short scale moving iron ammeter 240 scale moving iron ammeter Watt/VAR/Phase Angle meter Recording ammeter Maximum Demand Indicator Combined MDI & ML ammeter Electronic Control System. 0.5 0.75-1.5 1-1.25 2-4 2-3.5 3-3.5 5-10
SELECTION OF CLASS OF ACCURACY OF MEASUREMENT CTS
APPLICATION a) b) c) d)
4
CLASS OF ACCURACY 0.5 1 1-3 5
All dimensions are in mm.
General tariff metering Nonrevenue measurements including power and energy General measurements Approximate measurements
SERIES CGECT, ENCLOSED MEASUREMENT CTS
GENERAL Series CGCT offers following features: 1. Tamper proof terminal cover. 2. Bus bar clamp. 3. Open circuit protection feature. 4. Multiple mounting options. 5. Multiple clamping options. 6. Carry CE mark. The CTs cover a range from 50 AMP to 2500 AMP and with 1 AMP or 5 AMP options on the secondary, with accuracies class of 0.5, 1, 3 and 5 for a wide range of VA ratings. SPECIFICATIONS Conform to BS 7626, 1993 and IEC 44, 1996 (earlier IEC 185, 1987) Primary current 50 A to 2500 A, Secondary current 5 A or 1A. Maximum voltage 660V. Test voltage 2.50kV, 50Hz for 1 minute. Thermal current 60 In, Dynamic current 150 In Flame resistant, high impact ABS plastic case, sealable terminal covers, Bulk head mounting bracket and busbar clamps provided as standard accessories. Available from 50/ 5A to 2500/5A in 3 sizes RANGE CGECT - 1 Suitable for bus bars 31.5mm 6.30mm or 32mm dia range from 50/5A to 150/5A.
152 133 112
CGECT-1
15.5
Width : 35 mm
78
32
65
54
15.5
52 62 79
CLAMP
CGECT-2
Width : 40 mm
100
26
41
31
21
15
13
65 76 89
65
CLAMP
Width : 46 mm
CGECT - 2 Suitable for bus bars 40mm 12.60mm or 32mm dia. and range from 75/5A to 400/5A. CGECT - 3 Suitable for bus bars 80 mm 25.2 mm or 47mm dia. and range from 300/5A to 2500/5A. For class and VA coverage for each rating of CT please refer the chart in the next page.
All dimensions are in mm.
41
76
CGECT-3
64
CLAMP
25 28 4 HOLES 10 32 133 150
81
SERIES CGECT, ENCLOSED MEASUREMENT CTS
RATIO
VA 2
CLASS 5
2.5 3 4 5 7.5 2 2.5
CLASS 3
3 4 5 7.5
CLASS 1
2 2.5 3 5 17.5 10
CGECT - 1
50/5 A 60/5 A 75/5 A 80/5 A 100/5 A 125/5 A 150/5 A
RATIO
VA 75/5 A 80/5 A 2
CLASS 5
2.5 3 5 7.5 10 15 2 2.5
CLASS 3
3 5 7.5 10 15
CLASS 1
2 2.5 3 5 7.5 10 15
CLASS 0.5
2 2.5 3 5 7.5 10 15
CGECT - 2
100/5 A 125/5 A 150/5 A 160/5 A 200/5 A 250/5 A 300/5 A 350/5 A 400/5 A
RATIO
VA 300/5 A 400/5 A 2
CLASS 5
5 7.5 10 15 2 5
CLASS 3
7.5 10 15 2
CLASS 1
5 7.5 10 15 2
CLASS 0.5
5 7.5 10 15
CGECT - 3
6
500/5 A 600/5 A 800/5 A 1000/5 A 1200/5 A 1600/5A 2000/5A 2500/5A
The shaded squares indicate the range upto which the CTs can perform.
SERIES CGCTP, TAPE WOUND MEASUREMENT CTS
The CGCTP range of CTs can measure currents from 30 Amps to 4000 Amps. Their accuracy allows operation within the range of 5% to 120% of the primary current. This accuracy depends on the load connected to the secondary of the CTs, which includes both the impedance of the connected measuring instruments and connecting cables. Clamp type termination as shown in the figure is the standard feature. Options of Flying lead or Moulded Terminal Block can be offered against request. to 4000 Amps. Available in six optimised frame sizes - CGCTP-1 to CGCTP-6. Cost effective, economical design. Secondary currents 1 Amp and 5 Amps. Can operate at temperature ranges from -20C upto + 70C ambient. Di-electric strength of 2.50 kV for one minute. Nominal frequency 50/60 Hz. Rated voltage 660V AC max. Short circuit thermal current (Ith) - 60 times rated primary current for one second Rated dynamic current (I Dyn) - 2.5 times Ith. Degree of protection IP40.
2 3 CLASS 3 4 5 7.5 3 CLASS 1 5
Optional Mount Bracket A B M 6 Screws
TYPE CGCTP - 1 CGCTP - 2 CGCTP - 3 CGCTP - 4 CGCTP - 5 CGCTP - 6
A 72 72 95 133 150 198
B 22 34 54 83 102 145
L 36 36 40 46 46 46
PERFORMANCE
Designed to comply with BS 7626, 1993 and IEC 44, 1996 (earlier IEC 185, 1987) Primary currents from 30 Amps
RATIO VA 30/5 A 40/5 A 50/5 A 60/5 A 75/5 A 100/5 A 150/5A RATIO VA 75/5 A 100/5 A 150/5 A 200/5 A 300/5 A 400/5 A RATIO VA 300/5 A 400/5 A 500/5 A 600/5 A 800/5 A 1000/5 A 1200/5 A RATIO VA 600/5 A 800/5 A 1000/5 A 1200/5 A 1600/5 A 2000/5 A RATIO VA 1200/5 A 1600/5 A 2000/5 A 2500/5 A RATIO VA 1600/5 A 2000/5 A 2500/5 A 3000/5 A 4000/5 A 2 3 CLASS 5 4 5 7.5
CLASS 0.5
CGCTP-1
CGCTP - 2
CLASS 5 7.5 10
15
CLASS 3 7.5 10
15
CLASS 1 7.5 10
15
CLASS 0.5 5 7.5
10
15
CGCTP - 3
CLASS 5 7.5 10
15
CLASS 3 7.5 10
15
CLASS 1 7.5 10
15
CLASS 0.5 7.5 10
15
CGCTP - 4
CLASS 5 7.5 10
15
CLASS 3 7.5 10
15
CLASS 1 7.5 10
15
CLASS 0.5 7.5 10
15
CGCTP - 6 CGCTP - 5
CLASS 5 7.5 10
15
CLASS 3 7.5 10
15
CLASS 1 7.5 10
15
CLASS 0.5 7.5 10
15
CLASS 5 7.5 10
15
CLASS 3 7.5 10
15
CLASS 1 7.5 10
15
CLASS 0.5 7.5 10
15
NOTE: The shaded squares indicate the range upto which the CTs can perform.
All dimensions are in mm
SERIES CGPRO, TAPE WOUND PROTECTION CTS
PROTECTION CTS
A protection CT is required to transform the primary current to secondary current up to a specified accuracy limit factor according to the particular classification as set out in the Standard Specification. ranges from -20C upto + 70C ambient. Di-electric strength of 2.50 kV for one minute. Nominal frequency 50/60 Hz. Rated voltage 660V AC max. Short circuit thermal current (Ith) - 60 times rated primary current for one second Rated dynamic current (I Dyn) - 2.50 times Ith. Degree of protection IP40.
TYPE CGPRO - 1 CGPRO - 2 CGPRO - 3 CGPRO - 4 CGPRO - 5 CGPRO - 6 A 85 100 110 140 165 200 B 22 34 54 86 103 144 L As mentioned in the shaded area of table below
M 6 Screws
PERFORMANCE
Designed to comply with BS 7626, 1993 and IEC 44, 1996 (earlier IEC 185, 1987) Primary currents from 50 Amps to 4000 Amps. Available in six optimised frame sizes - CGPRO-1 to CGPRO-6. Cost effective, economical design. Secondary currents 1 Amp and 5 Amps. Can operate at temperature
Ratio
VA 50/5 A 60/5 A 75/5 A 100/5 A 5
Optional Mount Bracket B in mm A in mm
Clamp type termination as shown in the figure is the standard feature. Options of flying lead or moulded terminal block can be offered against request.
CGPRO - 1
Class 10P10
7.5 5
Class 10P15
Class 5P10
5 7.5
Class 5P15
95 75 5 95 75 55 50 35 30 5 60 50 45 45 40 35 5 45 40 35 35 35 35 5 35 35 35 35 5 35 35 35 35 35
105
110
100 80 110
Ratio
VA 75/5 A 100/5 A 150/5 A 200/5 A 300/5 A 400/5 A
Class 10P10
7.5 10 15 20 5
Class 10P15
7.5 10 15 20
Class 5P10
10 15 20 5
Class 5P15
7.5 10 15 20
105 75 100 60 75 50 60 40 45 7.5 80 70 55 55 45 40 7.5 55 45 40 40 40 35 7.5 40 40 35 35 7.5 40 40 35 35 35 10 100 80 70 65 55 50 10 65 55 50 45 40 40 10 45 40 40 40 10 40 40 40 35 35
105 95 60 15
95 75 20
110 80 110 70 90 55 65 45 60 5 95 75 70 60 55 45 5 60 55 45 45 40 40 5 45 40 40 35 5 40 40 35 35 35 7.5 105 80 75 65 60 7.5 75 65 60 55 45 45 7.5 55 45 45 40 7.5 45 45 40 40 35
5 7.5 100 80 100 60 80 110 55 65 85 110 40 55 75 90 110 35 45 10 15 20 5 65 55 50 50 45 35 5 50 45 35 35 35 35 5 35 35 35 35 5 35 35 35 35 35 7.5 85 75 60 60 50 45 7.5 60 50 45 45 40 35 7.5 45 40 35 35 7.5 40 35 35 35 35
CGPRO - 2
105 80 100 65 80 100 50 65 80 10 15 105 85 75 100 70 90 60 75 50 65 10 70 60 50 50 45 40 10 50 45 40 40 10 45 40 40 40 35 15 90 75 65 55 55 45 15 55 55 45 45 15 55 45 45 40 40 20
85 75 60 45
95 70 60
90 75
90 15 20
Ratio
VA 300/5 A 400/5 A 500/5 A 600/5 A 800/5 A 1000/5 A
Class 10P10
Class 10P 15
Class 5P10
Class 5P15
5 7.5 10 100 80 110 75 85 110 65 80 105 60 70 80 50 65 75 5 65 60 50 45 45 45 5 45 45 45 40 5 45 45 40 40 35 7.5 80 70 65 55 50 50 7.5 55 50 50 45 7.5 50 50 45 45 40 10 105 80 75 65 60 50 10 65 60 50 50 10 60 50 50 50 45
CGPRO - 3
95 85 70 60 15 85 70 60 55 50 40 15 55 50 40 40 15 50 40 40 40 35
110 85 70 20 110 85 70 65 55 45 20 65 55 45 45 20 55 45 45 40 35
105 100 75 70 10 100 75 70 65 55 45 10 65 55 45 45 10 55 45 45 40 40
85 85 15 85 85 85 75 60 15 85 75 60 55 15 75 60 55 45 45
110 20
90 75 20 90 75 70 60 50 20 70 60 50 50 20 60 50 50 45 40
90 90 15 20
Ratio
VA 600/5 A 800/5 A 1000/5 A 1200/5 A 1600/5 A 2000/5 A
Class 10P10
Class 10P 15
Class 5P10
Class 5P15
CGPRO - 4
110 100 85 75 20 100 85 75 65 20 85 75 65 60 45
90 90 90 105 80 90 65 80 15 20 90 105 80 90 80 80 65 70 15 80 65 60 60 50 20 90 80 70 70 50
CGPRO - 5
Ratio
VA 1200/5 1600/5 2000/5 2500/5 VA 1600/5 2000/5 2500/5 3000/5 4000/5 A A A A
Class 10P10
Class 10P15
Class 5P10
Class 5P15
Ratio
CGPRO - 6
A A A A A
Class 10P10
Class 10P15
Class 5P10
Class 5P15
All dimensions are in mm.
SERIES IC, RESIN CAST CTS
Series IC CTs, cast in polyester resin and confirming to BS 7626, 1993 and IEC 44, 1996 (earlier IEC 185, 1987) are designed for measurement and protection with any accuracy class. The ID can be either circular or rectangular to suit various sizes of bus bars/links, to customer requirements. The cores are made from cold rolled grain oriented silicon steel continuous strips. Based on the ID requirement, a suitable former is used for making the core. As the grain oriantation of lamination gets disturbed in the process, the cores are annealed in a nitrogen furnace. SR. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Different sizes of moulds with adjustable side plate are used to suit the final overall dimensions of the CTs based on the ID specified by the customers. The CTs can be offered for VA burdens up to 50 VA. For metering CTs, these can be with class '1' or class '3' or class '0.5' accuracy. For protection accuracy class of 5P10, 5P15 and 5P20 can be offered. Special class 'PS' accuracy protection CTs are offered with the Knee Point Voltage and Secondary Resistance requirements, as specified. For lower ratios, the CTs will be wound primary type, with separate primary and secondary terminals. These CTs will Series IC, Bar Primary CTs
M5 TERMINAL
25
E A
have a short-time current rating of 60 times the rated primary current for one second. The insulation level of these CTs is for 3 kV for 1 minute. The CTs are offered with terminals. Sealing arrangement and mounting inserts can be provided on request. PROTECTION CTS
RATIO 100/5A 100/5A 125/5A 125/5A 150/5A 150/5A 150/5A 175/5A 175/5A 175/5A 200/5A 250/5A 300/5A 400/5A 630/5A 630/5A 800/5A 1000/5A 1250/5A 1250/5A 1600/5A 1600/5A 2000/5A 2000/5A 2500/5A 2500/5A 3200/5A 3200/5A 3200/5A 4000/5A 4000/5A
VA 5 7.5 5 7.5 5 7.5 10 5 7.5 10 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15
MEASUREMENT CTS ACC. D ABC CL. 1 30 95 110 70 1 30 110 125 85 1 30 95 110 70 1 30 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 95 110 70 1 35 110 125 70 1 45 110 125 60 1 45 110 125 60 1 45 110 125 60 1 70 130 145 60 1 90 150 160 50 1 90 150 160 50 1 85 150 160 50 1 130 200 210 50 1 85 150 160 50 1 130 200 210 50 1 135 200 210 50 1 150 215 225 50 1 150 215 225 50 1 135 200 210 50 1 150 215 225 50 1 170 235 245 50 1 135 200 210 50 1 150 215 225 50 1 210 270 280 50
E 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 75 75 75 100 75 100 100 100 100 100 100 100 100 100 125
VA 5 7.5 5 7.5 5 7.5 10 5 7.5 10 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15
ACC. 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10 5P10
D 30 30 30 30 35 35 35 35 35 35 35 35 45 45 45 70 90 90 85 130 85 130 135 150 150 135 150 170 135 150 210
ABC 110 125 110 130 145 125 110 125 110 140 155 125 110 125 110 140 155 125 140 155 125 140 155 110 140 155 125 140 155 125 140 155 125 140 155 125 140 155 120 140 155 110 140 155 110 170 180 110 170 180 80 170 180 80 170 180 75 210 220 75 170 180 75 210 220 75 235 245 75 250 260 75 250 260 70 235 245 70 250 260 70 270 280 70 235 245 70 250 260 70 315 325 70
D
C M6 INSERT FOR MOUNTING (6 MM DEEP THRD.)
E 50 75 50 75 50 75 75 75 75 75 75 75 75 75 75 75 75 75 75 100 75 100 100 100 100 100 100 150 100 100 150
WOUND PRIMARY CTS
M6 MOUNTING INSERT 4 NOS.
C
=
RATING 150 - 125 A 100 - 80 A 75 - 45 A 40 - 10 A RATING <TO 100A >TO 150A
TERMINAL TERMINAL S1 S2 P1 P2 M5 M5 M5 M5 L B H C 90 85 87 25 90 85 87 40 M 12 M 10 M8 M6 D E 67 50 67 50
9
S2 P1
S1
E
P2
=
=
MOUNTING INSERT
D L
ELEVATION
CTs are for metering (measurement) up to 20VA class 1.
All dimensions are in mm.
Product improvement is a continuous process. Hence data given in this catalogue is subject to change without intimation.
Series CGCT, enclosed DIN rail panel mounting measurement CTs. Series CGECT, enclosed panel mounting measurements CTs. Series CGCTP, tape wound, panel mounting measurement CTs. Series CGPRO, tape wound, panel mounting protection CTs. Series IC, resin cast, panel mounting measurement and protection CTs.
R SC
EW
CG International
International Operations of Crompton Greaves Limited
Jagruti, Kanjurmarg (East), Mumbai (Bombay) - 400 042. (INDIA) Telephones : +91-22-5555 8000 Direct : +91-22-5555 8954 Fax : +91-22-2577 4066 E mail : cgi@cgl.co.in Home Page : www.cglonline.com
T UN MO T AL ON CKE
CG.ID/38/CTs/RPT/03/06