100% found this document useful (1 vote)
1K views4 pages

15kv Phelps Dodge

This document provides specifications for an MV-90 15 kV 1C cable consisting of a copper conductor, XLPE insulation, metallic shield, and outer PVC jacket. Key details include the cable construction, applicable standards and testing, maximum operating temperatures, standard lengths, and ampacity ratings for 100% and 133% insulation levels. The cable is designed for primary power distribution in industrial, commercial, and power plant applications.

Uploaded by

Juan E Torres M
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views4 pages

15kv Phelps Dodge

This document provides specifications for an MV-90 15 kV 1C cable consisting of a copper conductor, XLPE insulation, metallic shield, and outer PVC jacket. Key details include the cable construction, applicable standards and testing, maximum operating temperatures, standard lengths, and ampacity ratings for 100% and 133% insulation levels. The cable is designed for primary power distribution in industrial, commercial, and power plant applications.

Uploaded by

Juan E Torres M
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MV - 90 15 KV 1C

15 kV Copper Conductor, XLPE Insulation, Metallic Shield and Outer PVC Jacket

Metalic Shield

Insulation Shield 90C

Copper Conductor

PVC Jacket

Conductor Shield semi-conducting

Detail Description or Construction


Conductor Compacted copper conductor class B Conductor Shield Thermosetting extruded semi-conducting compound Insulation 100% or 133% Cross-linked Polyethylene (XLPE) 90C extruded in a real triple extrusion process Insulation shield Thermosetting extruded semi-conducting compound, adequate adhesion to the insulation and easy of stripping Metallic shield Uncoated helically applied copper wires or copper tape, as requested

Jacket Extruded black sunlight resistant, ame retardant, oils resistant PVC jacket with excellent mechanical properties Packaging Non-returnable wooden drums Options Compressed conductors Filled strand Tree retardant XLPE compound Copper tapes metallic shield Halogen free jacket CT USE applications Water blocking tapes Black Polyethylene Jacket

Application
Primary power and distribution circuits in industrial, commercial and power circuit generating plants. Single conductors cables, 1/0 AWG and larger, can be marked for CT Use to be installed in ladder cable tray, according NEC Article 318. MV-90 cable with water blocking conductor and water blocking tapes, are specially designed to be installed in high humid installations.

www.pdic.com

PDIC01123 | 11.19.04

MV - 90 15 KV 1C
15 kV Copper Conductor, XLPE Insulation, Metallic Shield and Outer PVC Jacket

Standards / Testing Specications


MV-90 meets or exceeds the requirements of ICEA S-93-639, AEIC CS5, UL 1072, Articles 310 and 326 of National Electrical Code.

Marking
Sunlight resistant and for CT Use.

Installation
MV-90 cables may be installed in wet or dry locations at maximum operating temperature of 90C for normal operation; 130C for emergency and 250C for short circuit conditions. Cables may be installed indoor and outdoor, exposed to sunlight, in raceway, conduit, duct or aerially supported by a messenger and directly buried according NEC 250-51.

Packing
Non Returnable wooden reel with 300 m standard lengths or according reel capacity and minimum bending radius.

www.pdic.com

PDIC01123 | 11.19.04

MV - 90 15 KV 1C
15 kV Copper Conductor, XLPE Insulation, Metallic Shield and Outer PVC Jacket

MV90 15KV 100% INSULATION LEVEL Conductor Size AWG / MCM 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000 Conductor Diameter mm 6.9 7.8 8.8 9.8 11.0 12.4 13.4 15.9 19.3 24.7 28.5 Insulation Thickness mm 4.45 4.45 4.45 4.45 4.45 4.45 4.45 4.45 4.45 4.45 4.45 Insulation Diameter mm 17.3 18.1 19.1 20.1 21.3 22.7 23.8 26.7 30.1 36.4 40.2 Jacket Thickness mm 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.79 2.79 Total OD mm 25.7 26.7 27.7 28.8 30.1 31.5 32.9 36.1 39.0 47.6 52.6 Total Weight kg / km 880 981 1,111 1,272 1,461 1,706 1,936 2,515 3,302 5,011 6,438 Ampacity (A) Buried Duct 20C Amb. Temp Free Air 40C Amb. Temp

155 175 200 230 260 295 325 390 465 565 640

195 225 260 300 345 400 445 550 685 885 1060

www.pdic.com

PDIC01123 | 11.19.04

MV - 90 15 KV 1C
15 kV Copper Conductor, XLPE Insulation, Metallic Shield and Outer PVC Jacket

MV90 15KV 133% INSULATION LEVEL Conductor Size AWG / MCM 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000 Conductor Diameter mm 6.9 7.8 8.8 9.8 11.0 12.4 13.4 15.9 19.3 24.7 28.5 Insulation Thickness mm 5.46 5.46 5.46 5.46 5.46 5.46 5.46 5.46 5.46 5.46 5.46 Insulation Diameter mm 19.3 20.3 21.2 22.3 23.5 24.8 26.0 28.7 32.0 38.4 42.1 Jacket Thickness mm 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.03 2.79 2.79 Total OD mm 27.8 28.8 29.8 30.9 32.2 33.6 35.6 38.2 41.0 50.7 54.6 Total Weight kg / km 960 1,071 1,206 1,376 1,569 1,818 2,098 2,644 3,439 5,282 6,625 Ampacity (A) Buried Duct 20C Amb. Temp Free Air 40C Amb. Temp

155 175 200 230 260 295 325 390 465 565 640

195 225 260 300 345 400 445 550 685 885 1060

www.pdic.com

PDIC01123 | 11.19.04