Air Handling Unit - Main Parts
The Base Frame
The each module of AHU is mounted on a continuous beam of galvanised steel channel held together with die cast
aluminium base corners with lifting holes for easy handling. Extruded aluminum alloy base is also available as option.
Frame Work
The modular framework is made of anticorrosive extruded aluminium profile. Different types of profiles are available to
choose from.
The Coil Section
We offer a wide range of chilled water, direct expansion, hot water & steam coils upto 12 rows deep. The coils are
computer selected to obtain optimum psychometric efficiency 2 with low air & water pressure drops. Each coil is pressure
tested at 21 kg / cm under water for trouble free operations. Coils with anticorrosive aluminium fins, copper fins, copper
header with MS adopter and MS header is also available as option.
The Drain Pan
The unique design aluminium construction drain-pan with multi slope ensures complete drainage of the condensate &
prevents growth of microbes during off or heating cycles.
The Panel
Standard 25mm / 43 mm panels are made of prepainted / precoated / GSS Sheets injected with environment friendly PUF
of uniform density of 40 3 +2 kg/m . The panels are fixed to the frame work using special imported self drilling & tapping
screws. To ensure air tight construction, self sticking gaskets are provided between the panel & frame. For specialized
applications food grade gaskets are provided. Choice of Al / SS304 / Prepainted sheet as inner skin.
Hinges & Locks
All access doors & panels are provided with hinges & locks made of self extinguishing nylon. The access panels are fitted
to the panel using multifinned gasket which provide perfect air tightness & can be removed easily using hand tools. Food
grade gasket is also available.
The Fan & Motor Module
High energy efficient forward / backward curved aerofoil AMCA certified centrifugal fans are available for all
applications. The fan & motor is mounted on a common channel fitted with anti-vibration isolators to avoid the vibration
transfer to main casing. The fan is connected to the casing using self extinguishing fabric flexible connection. Direct drive
plenum fan is also available for special applications. The limit switch is also provided on fan door for human safety.
The Filter Section
Fully sealed filter sectons are designed for easy installtion & removal. A complete range of filters with various
efficiencies and media are available as per requirements. Pressure measurement ports can be provided across fine filters
as option.
The Air Mixing Section
Fresh air & return air can be mixed at the desired rate with dampers that are specially designed for maximum air
efficiency. Motorized / Manual damper in extruded aluminium aerofoil design / GSS / SS construction is available. A
combination of 2 way or 3 way mixing chamber is also
available.
Average Pressure Drop of ATU Components
The Accessories & Options
Lamp switch as option
Variable frequency drive with bypass arrangement
Contoured / G.I. / Pre Coated aluminium roof for outdoor application.
Intake louvre with bird screen for fresh air intake.
Buckhead lamp as
standard
Outlet cowl with bird screen for exhaust unit.
Fire retardent flexible joints for Inlet & outlet of the unit.
Sound attenuation section for low noise applications.
Humidification section with wet deck 100 mm or 200 mm / spray type with inlet vanes & mist eliminator / steam humid
type humidif ier for critical applications.
Face & bypass / bypass damper section.
Drift eliminators in PVC / SS / Aluminium / G.I.
Condensate drain pump for underground installations.
Inspection window as
standard
Electric heater section for heating / humidity control.
Cross flow plate type, wheel type heat recovery and heat pipe can be supplied as an integral part of the unit for energy c
EFF-1 Motor
UV Tube
Units with Flat Belt
Units with VFDs
Limit Switch
Micro processor control panel with required field sensors duly wired to the unit.
The Safety
Provision for electrically interlocked fan section with access door
VWire guard for fan section
Earthing of fan & motor
Pressure Guage
The shown pressure drop values are average values. Exact values can be determined with computer selection and type of c
used.
Heat Recovery Wheel
Air Handling Units
Unit Model
Unit CFM
Unit Overall Dimensions
Coil Face Area
Length (mm)
Width (mm)
Height (mm)
Unit Base
(mm)
Sq. Feet
Fan Model
Motor
(Kw)
FLHU-010
1000
1300
850
620
100
2.0
7 x 7
0.55
FLHU-015
1500
1310
800
750
100
3.0
9 x 9
1.1
FLHU-020
2000
1320
950
850
100
4.2
10 x 10
1.1
FLHU-025
2500
1450
1100
800
100
5.0
12 x 12
1.5
FLHU-030
3000
1500
1240
880
100
6.25
315R
2.2
FLHU-040
4000
1620
1540
940
100
8.33
355R
3.7
FLHU-050
5000
1660
1540
1080
100
10.00
400R
3.7
FLHU-060
6000
1820
1540
1180
100
12.50
450R
5.5
FLHU-070
7000
1860
1540
1380
100
14.17
450R
5.5
FLHU-080
8000
1920
1540
1440
100
15.83
500R
5.5
FLHU-090
9000
1860
1800
1380
100
18.13
560R
5.5
FLHU-100
10000
1860
1800
1500
100
20.14
560R
7.5
FLHU-110
11000
2040
2080
1440
100
22.76
630R
7.5
FLHU-120
12000
2040
2080
1500
100
23.96
630R
7.5
FLHU-130
13000
2040
2080
1680
100
26.35
630R
7.5
FLHU-140
14000
2040
2080
1760
100
28.75
630R
9.3
FLHU-150
15000
2180
2150
1760
100
30.00
710R
9.3
FLHU-160
16000
2220
2120
2020
100
33.54
710R
9.3
FLHU-170
17000
2220
2120
2020
100
34.03
710R
11
FLHU-180
18000
2400
2280
2020
140
35.97
800K
11
FLHU-190
19000
2400
2660
1760
140
38.33
800K
11
FLHU-200
20000
2400
2780
1760
140
40.00
800K
11
FLHU-240
24000
2150
2650
2300
140
48.6
800
15
FLHU-300
30000
2330
2180
2550
140
62.5
900
15
FLHU-350
35000
2550
3260
2850
140
70.8
1000
15
FLHU-400
40000
2710
3420
3050
140
83.7
1000
18.5
Floor Mounted Vertical Units
Unit Model
Unit CFM
Unit Overall Dimensions
Coil Face Area
Length (mm)
Width (mm)
Height (mm)
Sq. Feet
Fan Model
Motor
(Kw)
FLFMVU-010
1000
600
900
1000
2.08
7/7.
0.55
FLFMVU-015
1500
600
1080
1120
3.13
9/9.
0.75
FLFMVU-020
2000
680
1180
1200
4.13
10/10.
1.1
FLFMVU-025
2500
660
1520
1150
5.10
9/9 X 2.
1.5
FLFMVU-030
3000
660
1550
1150
6.08
9/9 X 2.
1.5
FLFMVU-035
3500
660
1760
1150
7.05
9/9 X 2.
2.2
FLFMVU-040
4000
680
2020
1200
8.26
10/10 X 2.
2.2
FLFMVU-045
4500
680
2020
1260
9.44
10/10 X 2.
2.2
FLFMVU-050
5000
800
2140
1350
10.00
12/12 X 2.
3.7
FLFMVU-060
6000
800
2140
1450
12.50
12/12 X 2.
3.7
FLFMVU-070
7000
900
2240
1580
14.51
15/15 X 2.
3.7
FLFMVU-080
8000
900
2320
1640
16.67
15/15 X 2.
5.5
Ceiling Suspending Unit
Unit Model
Air Qty.CFM
Unit Overall Dimensions
Coil Face Area
Length (mm)
Width (mm)
Height (mm)
Sq. Feet
Fan Model
Motor
(Kw)
FLCSU-010
1000
1100
880
480
2.08
7/7.
0.55
FLCSU-015
1500
1160
1030
560
3.13
9/9.
0.75
FLCSU-020
2000
1200
1120
610
4.01
10/10.
1.1
FLCSU-025
2500
1200
1500
560
5.00
9/9 X 2.
1.1
FLCSU-030
3000
1200
1740
560
6.04
9/9 X 2.
1.5
FLCSU-035
3500
1200
1950
560
7.45
9/9 X 2.
1.5
FLCSU-040
4000
1260
1950
610
8.02
10/10 X 2.
2.2
FLCSU-045
4500
1260
2150
610
8.99
10/10 X 2.
2.2
FLCSU-050
5000
1300
1750
780
10.07
12/12 X 2.
2.2
FLCSU-050
5000 (OPT)
1300
2100
690
10.00
12/12 X 2.
2.2
FLCSU-060
6000
1300
2050
780
12.15
12/12 X 2.
3.7
FLCSU-060
6000 (OPT)
1300
2480
690
12.08
12/12 X 2.
3.7
FLCSU-070
7000
1460
2000
910
14.17
15/15 X 2.
3.7
FLCSU-070
7000 (OPT)
1460
2330
780
14.06
15/15 X 2.
3.7
FLCSU-080
8000
1460
2230
910
16.04
15/15 X 2.
3.7
FLCSU-080
8000 (OPT)
1460
2640
780
16.15
15/15 X 2.
3.7
Double Skin Ceiling Suspended Units
Unit Model
Air Qty.CFM
Unit Overall Dimensions
Coil Face Area
Fan Model
Motor (Kw)
Length (mm)
Width (mm)
Height (mm)
Sq. Feet
DD FAN
(SINGLE
PHASE)
FLCSUD-010
1500
900
1020
590
3.02
DD 9/9
0.37KW / 4P
FLCSUD-020
2000
960
1120
590
4.01
DD 10/10
0.55KW / 4P
FLCSUD-030
3000
1100
1400
660
6.11
DD 12/12
0.736KW /6P
FLCSUD-040
4000
960
1950
590
8.02
DD 10/10 # 2
0.55KW / 4P # 2
FLCSUD-050
5000
1100
2100
660
10.00
DD 12/12 # 2
0.736KW / 6P #2
FLCSUD-050
5000 (OPT)
1100
1750
780
10.07
DD 12/12 # 2
0.736KW / 6P # 2
FLCSUD-060
6000
1100
2480
660
12.08
DD 12/12 # 2
0.736KW / 6P # 2
FLCSUD-060
6000 (OPT)
1100
2050
780
12.15
DD 12/12 # 2
0.736KW / 6P # 2
Ventilation Units
Unit Model
Air Qty.CFM
Unit Overall Dimensions
Length (mm)
Width (mm)
Height (mm)
Unit Base (mm)
Fan Model
Motor (Kw)
FLVU-010
1000
800
650
550
100
7" X 7"
0.55
FLVU-015
1500
880
750
580
100
9" X 9"
1.1
FLVU-020
2000
930
850
625
100
10" X 10"
1.1
FLVU-030
3000
1000
870
700
100
12" X 12"
1.5
FLVU-040
4000
1125
1030
790
100
15" X 15"
2.2
FLVU-060
6000
1280
1200
980
100
18" x 18"
3.7
FLVU-080
8000
1425
1360
1220
100
500
5.5
FLVU-100
10000
1500
1450
1370
100
560
5.5
FLVU-120
12000
1600
1525
1500
100
560
5.5
FLVU-150
15000
1600
1650
1480
100
630
7.5
FLVU-180
18000
1900
1850
1660
100
710
9.3
FLVU-200
20000
2050
2050
1740
100
800
9.3
FLVU-240
24000
2050
2050
1850
140
800
11
FLVU-300
30000
2300
2300
1940
140
900
15
FLVU-350
35000
2400
2500
2080
140
1000
15
FLVU-400
40000
2500
2600
2080
140
1000
18.5