Vib Scanner
Vib Scanner
Machine diagnostics
       and data collection
Operating instructions
Dear Customer,
                     Foreword
                     This manual describes the main functions of the VIBSCAN-
                     NER as well as the most important steps of its operation.
                     The optional firmware modules ‘FFT Analysis’, ‘Balancing’
                     and ’Signal Analysis’ are described in the manual ‘VIB-
                     SCANNER - FFT-Analysis & Balancing’ (VIB 9.664.G).
                     An online help function is integrated in the instrument that
                     can be called up at any time via the menu.
                     This manual is valid for firmware version 1.60 and higher.
                     Safety
                     VIBSCANNER must be treated in such a way that it is not
                     subject to any mechanical knocks.
                                                                                     CAUTION!
                     The housing is made of an electrically conducting plastic.
                     Consequently, the instrument may only be used to measure
                     small signal voltage (±30V) or small signal current
                     (±20mA).
                     VIBSCANNER is only dustproof and watertight (IP65) when
                     the battery is plugged into the instrument. Please note that,
                     during the battery change, the instrument and the battery
                     only comply with protection class IP 50 (dustproof).
                     For signal measurement and for data transmission, only use
                     the connecting cable provided for this (see VIBSCANNER
                     Product Catalog VIB 9.661-4DG).
                     The relevant safety regulations must be observed during
                     measurements on machines.
                     Authorized use
                     - VIBSCANNER may only be used to record machine
                       signals within industrial environments.
                     - Transducers and cables may only be used for their
                       respective intended tasks as described in the correspond-
                       ing sales leaflets.
                     Any other use constitutes improper use and is prohibited.
                     PRÜFTECHNIK AG assumes no liability for damage result-
VIBSCANNER 09.2003
Contents
           Description ............................................................ 8
              Interfaces and functional elements ................................ 8
                 Transducer module ................................................................ 9
              Power supply .............................................................. 10
           Operation ............................................................ 13
              Operating elements .................................................... 13
              Program structure ....................................................... 14
              Getting started ........................................................... 16
                 Setup menu ........................................................................ 17
                 Changing parameters .......................................................... 18
                 Instrument setting (setup) ................................................... 19
              Multimeter measurement ............................................ 22
                 Vibration measurement using an int. transducer ................. 22
                 Results display for 3 characteristic overall values .................. 23
                 Saving the result ................................................................. 24
                 Temperature measurement ................................................. 26
                 RPM measurement .............................................................. 27
                 Shock pulse measurement (bearing condition) .................... 28
                 Manual input of the measured value ................................... 30
                 User-defined measurement tasks ......................................... 31
                 Adapted measurement tasks ............................................... 32
                 Trend ................................................................................... 33
                 Zooming the trend curve ..................................................... 34
                 Trend information ............................................................... 35
              Route / Pool measurement .......................................... 36
                 Options in the Route mode ................................................. 38
                 Icons in the measurement task screen ................................. 38
                 Adaptive measurement task ................................................ 39
                 Visual inspection ................................................................. 41
                 Route / Pool measurement with VIBCODE ........................... 42
                 Graphical route (‘Machine scan’) ......................................... 43
                 RPM-dependent parameters ................................................ 46
              Signal output .............................................................. 50
                 Headphones ........................................................................ 50
           Limits ................................................................... 53
                 Display when a limit is exceeded ......................................... 53
                 Limits according to ISO ........................................................ 54
                 User-defined limits .............................................................. 56
           Transducers ......................................................... 58
                                                                                                                VIBSCANNER 09.2003
                     Appendix ............................................................. 63
                           Text editor ........................................................................... 63
                           Options in the File Manager ................................................ 64
                           Tips & Tricks ........................................................................ 66
                           Data exchange with the PC ................................................. 68
                           ISO 10816-3 ........................................................................ 69
                        Technical data ............................................................. 70
                        Troubleshooting .......................................................... 72
VIBSCANNER 09.2003
8
Description
Description
                                                                Transducer
                                                                module
                                                                (see next page)
LED indicators
Display
Joystick
                                                                  Battery with
                                                                  charging socket
                  LED indicators
                  Blue LED ...
                  ... lights up after the measurement if the result is valid.
                  Green LED ...
                  ... flashes / lights up during measurement with the internal
                      RPM transducers.
                  Red LED ...
                  ... flashes after the instrument is switched on: Battery is
                      empty.
                  ... flashes after the measurement: Meas. signal is overflow-
                      ing/ underflowing or is instable: Repeat measurement.
                  ... lights up after the instrument is switched on: Instrument
                                                                                    VIBSCANNER 09.2003
                     Transducer module
                     (view from above)
Protective caps
                                                                     IR transmitter
                                          Temperature
                                          probe                 Trigger (IR sensor)
                                                            LED
                                                            (red)
                         Power supply
                         The VIBSCANNER is supplied with a NiMH battery that is
                         charged by a battery charger (VIB 5.420). During the
                         charging process, the VIBSCANNER is switched off and the
                         battery remains inside the instrument. Reserve batteries
                         can also be charged outside the instrument.
                F
                Note
                           The NiMH battery loses 1- 2% of its charge (self-
                           discharge) per day when the VIBSCANNER is switched
                           off. If you do not need the VIBSCANNER for a longer
                           period of time (> 3-4 weeks), please remove the
                           battery and leave it connected to the charger (not in
                           the intrinsically safe version). Before you reinsert it,
                           recharge the battery.
                                                                          VIB 5.420
                                                                                                          11
                                                                                                 Description
                                                                                   Level of charge
                                                                                   (black= battery full)
              F
              Note
                       If the message appears during a measurement, you
                       have approximately another 30 minutes time to termi-
                       nate your work and save the data.
Operation
                     Operating elements
                     The VIBSCANNER has three operating elements:
                     Joystick
                     The joystick moves the cursor either horizontally or verti-
                     cally on the screen. By pressing down on the joystick
                     (‘clicking’), the selection is confirmed (ENTER function).
                     Function key
                     The function key is used to move the cursor from the
                     display field into the menu column and vice-versa. As a
                     result, you can delete incorrect entries in the text editor.
                     Escape key
                     The ‘Escape key’ is used to cancel a selection. It enables you
                     to return to the higher menu from a submenu.
                                 Program structure
                                 The VIBSCANNER application program is graphic-oriented
                                 and menu-driven.
                                 Graphic-oriented
                                 a) The measurement tasks are started via corresponding
                                    icons on the screen.
                                 b) In the basic version the measurement tasks are stored in
                                    two screens that are opened via the screen icon S1 or S2:
                                   The S1 screen contains measurement tasks for overall
                                   vibration and other important variables (see page 16).
                                   The S2 screen contains measurement tasks for overall
                                   vibration that are optimized for specific machine types
                                   and RPM ranges. The first line depicts the machine types
                                   and the left column defines the RPM range (see page
                                   32).
                                 c) A corresponding selection screen exists for the optional
                                    program modules ‘FFT analysis’, ‘Balance’ and ‘Signal
                                    Analysis’ (details of the optional modules are given in
                                    the ‘VIBSCANNER - FFT analysis and balancing’ operat-
                                    ing manual - VIB 9.664.G).
                     Menu-driven
                     a) All functions (e.g. Setup, Help, Save , File,...) are called
                        up via the menu column.
                        The menu column is hidden in some submenus due to
                        lack of space. To display it, either press the function key
                        or move the joystick to the right.
                     b) All the measurement and instrument parameters are
                        listed in menus and can be changed with the joystick.
                        Some menus branch further into submenus to provide a
                        clearer overview (e.g. VIBSCANNER Setup).
                                                                            Menu
                                                                            column
                      Meas.
                      parameters
                                    Getting started
                                    Push the joystick upwards towards the display for one to
                                    two seconds. Leave go of the joystick and the VIBSCANNER
                                    main window appears:
                          Cursor
                  (reverse video)
                                                                             Menu column
                  Display field
Status line
                                    Main window1
                                    The following measurement tasks can be started directly
                                    via the relevant icon in the display field:
                                    Preset measurement tasks (line 1):
                                       - Vibration velocity
                                       - Shock pulse measurement (bearing condition)
                                       - Cavitation (e.g. in pumps)
                                    Preset measurement tasks (line 2):
                                       - RPM
                                       - Temperature
                                       - Vibration displacement
                                       - Vibration acceleration
                                    User-defined measurement tasks (line 3)
                                       - Manual input of measured values
                                       - Measurement of small signal currents / voltages (DC)
                                       - Measurement of small signal currents / voltages (AC)
                                    S: Icon for the measurement of characteristic overall val-
                                       ues. Clicking on it calls up the next screen that has
                                       measurement tasks.
                                    VIBSCANNER setup: Instrument settings
1
 The sequence of the selection        FILE: to open the File manager
screens can be changed (p. 19)        ROUTE: to start the ‘Route’ operating mode
² only in the optional balancing
                                      SETUP: Settings for measurement, transducer, evalua-
and ‘Analysis’ module                 tion, recording², machine²
                                      HELP: Online help on the highlighted icon
                                      OFF: to switch off the instrument
                                                                                                      17
                                                                             Operation - Getting started
                     Setup menu
                     In the Setup menu, you can check the parameters of the
                     selected measurement task and change them if necessary.
Setup menu
                                     Changing parameters
                                     Click on the parameter to open an entry mask, the text
                                     editor or a submenu:
                                     • Parameter type ‘Number’: Press the joystick up/ down to
                                       change the value; Press the joystick to the left/ right to
                                       select the units, 10s, 100s, 1000s digits (multidigit
                                       numbers can be set up more quickly in this way).
                                     • Parameter type ‘Text’: Enter the text in the text editor
                                       (see page 63)
                                     • Parameter type ‘Selection’: The settings are selected
                                       from a submenu (i.e. ‘Units’). If only a few parameters
                                       are available for selection, the submenu does not ap-
                                       pear. The parameters can be set simply by clicking on
                                       them (e.g. ‘tool tips = yes/no’).
                                     The cursor for variable parameters is displayed in reverse
                                     video. A frame appears around non-variable parameters.
                     COMPANY: Company name; enter in the text editor*.                 *Details of the text editor are
                     POWER OFF (MIN.): Instrument switches off if no action takes      given on page 63
                       place in the selected period of time (never, 1..250 min.).
                       No automatic switch-off occurs for the ‘Never’ setting.
                     BAUD   RATE:   Speed of data transmission.
                     DISPLAY: Click on ‘Select’ to change the following settings:
                      CONTRAST: Can be set between 1 and 63; the optimum
                       setting lies between 40 and 50 units.
                      BACKLIT STAGE: Display illumination can be adjusted be-
                       tween 0 (no illumination) and 3 (very light). To save
                       energy, the illumination should be set to ‘0’ when
                       working in light rooms.
                      BACKLIT.OFF (S): Illumination switches off if no action takes
                       place in the selected period of time (Never, 1...240 s). To
                       switch it on again, press any key.
                      SCREEN SEQUENCE: Sequence of selection screens. To alter
                       the position of a screen, click on the list and select the
                       required screen.
                      TOOLTIPS: In addition to the online help, a brief text can be
                       displayed for each icon marked on the screen.
                      GRAPHIC ROUTE: Display the graphic symbols in a ‘graphic
                       route’ (‘Yes’) or display the corresponding text-based
                       route (‘No’).
                      PRESEL. SIGNAL TYPES: Display of the transducer signal type in
                       the transducer selection list.
                      DISPLAY CHANNEL A/B: The ‘A/B’ option, which can be used
VIBSCANNER 09.2003
                                                                                    Transducer list:
                                                                                    ‘Available transducers’ with
                                                                                    signal type
                               Multimeter measurement
                               VIBSCANNER can be used as a measuring instrument for
                               characteristic overall values. This section describes the
                               operating sequence of these measurements in the multime-
                               ter mode.
                 F
                 Note
                                 Countersink the measurement location (e.g. with spe-
                                 cial countersink bit VIB 8.610) and clean it.
                        Unit
                                                                                              VIBSCANNER 09.2003
RMS / 0-peak-value
                Transducer
                                                                                                         23
                                                                                     Operation - Multimeter
                                                                                       F
                     Before the measurement:
                     If the internal vibration transducer is not selected in the
                     transducer setup, an error message appears (for external          Note
                     transducer, see page 58). If a sensor fault or line fault
                     (short-circuit, open line) occurs, a corresponding error
                     message also appears.
Text editor
                             Temperature measurement
                             The temperatures of surfaces and liquids can be measured
                             with the built-in temperature probe (-50 to +100 °C).
                             External transducers must be used for wider temperature
                             ranges (see page 60)
                 FNote
                               Please note that it can take some seconds until the
                               probe reaches the temperature of the surface. If neces-
                               sary, perform a second measurement.
                               The measurement stops when the temperature is stable
                               for N consecutive measurements. N is the number of
                               averages in the ‘Measurement’ setup. At least three
                               measurements must be performed. After 4xN measure-
                               ments, the measurement is stopped and the last mea-
                               sured value is accepted.
RPM measurement
              F
              Note
                           To measure high frequency shock pulse signals, use
                           either the internal vibration transducers, the TIPTEC-
                           TOR, the VIBCODE hand-held probe or industrial
                           transducers with a resonant frequency of 36kHz from
                           PRÜFTECHNIK AG.
                           Mount the transducer at the location with the strongest
                           signal within the load zone. The signal path to the
                           measuring location should be direct and include only
                           one material transition. For measurement with the
                           internal transducer or the TIPTECTOR, the measure-
                           ment location should be prepared with the countersink
                           bit (VIB 8.610).
              F
              Note
                           The RPM and shaft diameter determine the initial
                           value (dBi). External influences on the signal are taken
                           into account in the adapted value, dBa. Both factors
                           result in the adapted initial value, dBia:
                         New transducer:
                         • Click on the first line (‘->’) to display the list of ‘manual’
                           transducers.
                         • Press the function key and click on ‘New’ in the menu.
                         • Enter a name in the text editor.
                         • Set up the following parameters:
                            SENS. NAME: Name of transducer (text editor)
                            MEAS.TYPE: Measured quantity depends on the signal type
                            SIGNAL TYPE: Set to ‘manual’
                            EDIT QUANTITY: Description of the measured quantity
                            ENGIN. UNIT: Unit (text editor)
                            DECIMAL: Decimal places of the results display
                                     Machines
                     Adapted         (general)   Gears   Bearings
     vibration measurements:
              2nd window (S2)
High RPMs
Medium RPMs
                     FNote
                                  For a detailed description of the measurement task,
                                  select the relevant icon and click on ‘Help’ in the menu.
                                  To display the measurement tasks for low RPM ranges,
                                  move the cursor across the lower edge of the window.
                                                                                                VIBSCANNER 09.2003
                                                                                                         33
                                                                                     Operation - Multimeter
                     Trend
                     The development of the machine condition can be recorded
                     and documented with the aid of a trend measurement. In
                     this case, characteristic values are always regularly record-
                     ed at the same measurement location under the same
                     conditions. The results are saved in a file.
                     Trend display
                     • Mark a measurement task in the selection screen (S1,
                       S2), and click on ‘File’ in the menu to open the file
                       manager (see Note, page 25):
                                                                                       ‘File Manager’
                                                                                        (see page 64)
                                                                                        Limit for
                                                                                        ‘Alarm’
                                                                                        ‘Warning’
                                                                                        ‘Prewarning’
                     Joystick functions:
                     Right/ left: Move the cursor along the trend curve
                     Top/ bottom: Display trend for RMS, 0-p, p-p
                     Double-click: Start a new measurement
VIBSCANNER 09.2003
                                 Procedure:
                                 • Move the cursor to the section to be zoomed.
                                 • Click once with the joystick:
                     Trend information
                     The measured value, date and time for each individual
                     measurement are saved.
                       F
                                    The aggregate list may – according to the hierarchical
                                    structure in the OMNITREND database – also contain
                       Note         individual machines or measurement locations.
                                                                                                       37
                                                                                        Operation - Route
                                                                                    Selection of the
                                                                                    measurement location
                                                                                    Selection of the
                                                                                    measurement task
                      Event
                      You can store additional information on special incidents
                      on the machine together with the measuring result. You
                      can select these data from a predefined event list (EVENT)
                      and add a comment (COMM) to the data record if necessary.
              FNote
                        To display text that runs off the right-hand edge of the
                        screen, push the joystick to the right.
                                                                                                   41
                                                                                    Operation - Route
                     Visual inspection
                     In addition to electrically measurable machine signals, you
                     can also record and further process inspection data with the
                     VIBSCANNER. The data are either recorded as an event or
                     selected from a list with predefined results. For example,
                     you can be asked to check the oil level at a pump:
               Location and
       measurement direction
                    RPM-dependent parameters
                    The RPM is required as an additional parameter in the
                    following measurements:
                    • Shock pulse measurement ->
                      for the normalization of carpet and maximum value
                    • FFT spectrum ->
                      for the display of RPM-dependent (damage) frequencies
                      in OMNITREND
                    So that the RPM does not always need to be recorded
                    before each of these measurements, VIBSCANNER together
                    with OMNITREND provides the following functions for the
                    route mode:
                    • Aggregate RPM
                    • Production line speed
                    Aggregate RPM
                    For a single aggregate (e.g. motor-gear-pump), a reference
                    RPM is always recorded first. The RPM value is then
                    converted for all measurement locations on the aggregate
                    and saved together with the results of the measurements
                    listed above. The conversion factors are defined in OMNI-
                    TREND and take into account the different RPM relations in
                    the aggregate (e.g. in gearing).
                                                                    Reference RPM
                                                         Gear
                                                         spectrum
                                      Shock pulse
                                      (roller bearing)                       Motor spectrum
                                                                                              VIBSCANNER 09.2003
                                                                                                   47
                                                                                    Operation - Route
ni: RPM n1 n2 n3
                     If you leave the entry screen with ‘ESC’, and want to start a
                     measurement, the following warning appears:
                      Signal output
                      The recorded vibration signal is available at the analog
                      output (yellow socket). It can be tapped with the VIBSCAN-
                      NER cable - VIB 5.431 - and displayed on a further
                      processing measuring instrument (oscilloscope, vibration
                      analyzer,...). The signal can be listened to via a headphone
                      that is directly connected (VIB 6.670).
VIB 6.670
VIB 5.431
                      Headphones
                      The headphone is used to listen to the machine vibration
                      signal (vibration acceleration) or the bearing signal (shock
                      pulse).
                      Measuring procedure
                                                                                     VIBSCANNER 09.2003
VIBSCANNER 09.2003
                                                                                             53
                                                                                          Limits
Limits
Setup menu
                     • Click on ‘ISO 10816-3’ to select the machine group and       * For details, see Appendix,
                       the type of foundation*.                                     page 69
                                                                                    Limits for
                                                                                    vibration velocity
                                                                                    (ISO 10816-3; Group 3, rigid
                                                                                    foundation)
                                     User-defined limits
                                     The new setup and changing of user-defined limits is shown
                                     using the example of a temperature measurement:
                         F
                         Note
                                       If no evaluation setup is yet active:
                                       Activate the evaluation setup (previous section) and
                                       select a setup in the following screen (e.g. ‘Temp1’):
                                                                                     1 = Alarm
                                                                                     2 = Alarm & warning
                                                                                     3 = Alarm & warning &
                                                                                         Pre-warning
menu.
Transducers
           Connecting an
      external transducer
                F
                Note
                                VIBSCANNER automatically recognizes the transducer
                                connected to the blue analog socket. If another trans-
                                ducer type is selected in the transducer setup, the
                                measurement is not performed. Also in the case of
                                short-circuit or open line, VIBSCANNER does not start
                                the measurement.
                                VIBSCANNER only displays those transducers for selec-
                                                                                         VIBSCANNER 09.2003
Transducer setup
                     • Click on the first line (‘->’) to display the list of available   *Preselection of the transducers
                                                                                         takes place in the instrument
                       transducers*:
                                                                                         setup (page 20)
                                                                                         F
VIBSCANNER 09.2003
             F
             Note
                           The transducer type is not automatically recognized
                           when the probe is connected to the QLA socket.
Appendix
Text editor
Text line
                     Capital letters:
                     • Double-click on the letters
                     To cancel the input and close the text editor, use the Escape
                     key.
VIBSCANNER 09.2003
64
Appendix
File Manager
                          1. To display a file:
                          • Click on the required file in the list, or on ‘Load’ in the
                            menu to open the marked file.
                          2. To create a directory:
                          • Click on the higher directory to open it.
                          • Click on ‘MkDir’ (‘Make directory’) and enter the directo-
                            ry name in the text editor.
               F
              Note
                            A directory can only be deleted if it no longer contains
                            any files.
                                                                                          65
                                                                                    Appendix
                     5. To copy/move a file:
                     • Mark the file and click on ‘Copy’ in the menu.
                     • Click on the required directory to open it.
           b. Tooltips
           In addition to the online help, a brief text can be displayed
           for each symbol marked on the screen. The ‘Tooltips’
           function can be switched on/off in the VIBSCANNER setup
           (Option ‘Display’).                                             VIBSCANNER 09.2003
             F
             Note
                          The definition of the measurement tasks and the
                          evaluation of the measurement data collected is per-
                          formed using the OMNITREND PC software (VIB
                          8.955).
ISO 10816-3
7.1
                                                                                                                 4.5
                                                                    C                                            3.5
                                                                                                                 2.8
                                                                     B
                                                                                                                 2.3
                                                                                                                 1.4
                                                                     A
                                                                                                                 0.71
                                                                                                                        mm/s
140
                                                                                                                   90
                                                                                                                   71
                                                                     C                                             56
                                                                                                                   45
                                                                                                                   36
                                                                     B                                             28
                                                                                                                   22
                                                                                                                   18
                                                                     A
                                                                                                                         µm
VIBSCANNER 09.2003
11
                                                                                               Newly commissioned
                     C        Short-term operation allowed                              A
70
Appendix
     Technical data
     Hardware
     Measurement channels                                   Temperature range
        Analog: Vibration signals (LineDrive, ICP®)            Operation     0... +60°C / 32...140°F
                 Temperature (Pt 100, NiCrNi)                  Storage      -20... +65°C / -4...160°F
                 Transducer and instrument outputs
                 AC (± 30V; 0-20mA)                         Dimensions (HxWxD)
                 DC (± 30V; 0-20mA)                            250 x 100 x 55 mm / 9.8 x 3.9 x 2.2 inch
        Digital: Trigger (5V TTL)
                                                            Weight
     Outputs                                                   approx. 690 g / 24 oz.
         RS 232 (PC conn., up to 115 kbaud), Head-
                                                            Transport case
         phone, Analog signal (4Vpp; Rout= 200 Ohm)
                                                                Polypropylene, black
     Operating elements                                         Dimensions    390 x 340 x 90 mm
        1 joystick (Cursor & ENTER function)                    (HxWxD)       15.3 x 13.4 x 3.5 inch
        2 keys     (Menu and Escape)
                                                            Measurement range / Accuracy
     LED indicators                                            RPM            60 ... 60000 min-1 / 0.1‰
         Four LEDs for device status / signal evaluation       Temperature
                                                                • Pt 100      -50..+600°C / 1°+ sensor%
     Display                                                                  (-58 ...+1112°F)
         Graphical pixel display (backgr. illumination)         • NiCrNi      -50...+100°C / 0.5° + 3%
         Dimensions     54 x 27mm/ 2.1 x 1.1inch                   (internal) (-58...+212°F)
                        64 x 128 pixels                            (external) -50...+100°C / 0.5°+ sensor%
         Contrast       Adjustable                                            (-58...+212°F)
         Illumination Adjustable                                   (external) +100..+1000°C / 1°+ sensor%
                                                                              (212...1832°F)
     Power supply                                              Extra-low      -9...+9V / 2% (Ri=30kOhm,
     NiMH rechargeable pack (7.2V / 1.5 Ah)                    voltage        with cable VIB 5.440)
         Charg. dur. < 6 hours (intr. safe: <10 hours)         (AC/DC)        -30...+30V / 2% (Ri=100kOhm,
         Operat. dur. > 10 hours in intermit. use                             with cable VIB 5.433)
                        > 6 hours in continuous use            Extra-low      -20...+20mA / 2%;
                        with illumination                      current        4...20mA / 2% (Rshunt =200 Ohm
         Charg. display 2 LEDs (green, red)                    (AC/DC)        with cable VIB 5.434)
         Charg. temp. 10 ... 40°C / 50 ... 104°F
         ‘Sleep’ mode Adjustable                                For internal sensors, external sensors (1µA/ms-²
                                                                CLD*; 100mV/g ICP®) and external measure-
     Internal sensors                                           ment devices (1mV/ms-²), the following applies:
          Vibration/ shock pulse (bearing condition)
                                                                Displacement   <   9000 µm (p-p) / 1%
          RPM (IR sensor with light point for adjustment)
                                                                Velocity       <   9000 mm/s (p-p) / 1%
          Temperature (NiCrNi)
                                                                Acceleration   <   6000 m/s² (p-p) / 1%
     Signal processing                                          Shock pulses   <   81 dBsv / ± 3dB
         RMS, 0-P, P-P, max/carpet, envelope curve,
                                                            Fulfilled standards
         rectifying
                                                                  Frequency response according to ISO 2954 -
         Filter:    Highpass (2 /10 Hz; 1 / 5 kHz)
                                                                  other parameters and measured variables
                    Lowpass (1 / 5 / 40 kHz)
                                                                  according to DIN 45662 class 1
         Integrat.: Two selectable stages
         Sampling frequencies: Up to 64kHz (depending       Noise, internal sensor (from 10 Hz)
         on measuring range)                                    Velocity       0.1 mm/s eff.
                                                                Displacement 2µm eff. (instr.+sensor)
     Memory
                                                                Shock pulse < 0dBsv , peak
        4 MB
                                                            Compatibility (external transducer)
                                                                                                                   VIBSCANNER 09.2003
     Housing
                                                               Vibration
        ABS strengthened with steel fiber
                                                                         • CurrentLineDrive (CLD*) transducer
     Environmental protection                                            VIBCODE® for measurement studs
         IP 65                                                           with location recognition;
                                                                         TIPTECTOR® hand-held probe for
     Relative humidity                                                   vibration & shock pulse;
         10 ... 90%
                                                                                                                                        71
                                                                                                                                  Appendix
                                                                                   Firmware
                     Compatibility (external transducer)                           Measurement functions
                                  Quick fit transducer for SPM                        Velocity / displacement / acceleration in ma-
                                  measurement studs;                                  chine-specific measurement tasks;
                                  Industrial transducer with magnetic,                Shock pulse (bearing condition);
                                  threaded, adhesive mounting, with                   Temperature;
                                  adapter and hand-held probe                         RPM
                                  • ICP® transducer
                                  • Velocity detection (mV/mms-1)                  Process parameters
                                  • Displacement detection (mV/µm)**                   Manual input;
                        RPM       • Optical sensor (passive/ active)                   User-defined DC: ± 30V; -20...+20mA
                                  • 5V TTL (opt. or induct. transducer)                tasks         AC: ± 30V; -20...+20mA
                        Temp.     • NiCrNi (magnetic/ probe)                                         (Extra-low voltage/ current)
                                  • IR probe
                                                                                   Data processing
                                  • Pt100
                                                                                       Evaluation functions for characteristic overall
                     CE conformity (for cable length < 3m)                             value;
                         Interference EN 50081-1                                       Bearing diagnosis using shock pulse;
                         emission      (Residential area)                              Machine-condition evaluation according to ISO
                                                                                       standards (vibration according to the new
                          Interference   EN 50082-1                                    ISO 10816-3);
                          sensibility    (industrial area)                             Data collection functions for characteristic
                                         < 4% of meas. value or                        overall value and for machine inspection;
                                         < twice noise value
                                                                                   Measurement parameters
                                                                                      Averaging:  linear, peak hold, exponential,
                                                                                                  time-synchronous;
                                                                                                  Adjustable averaging no. & time
                     VIBSCANNER, intrinsic. safe                          II 2 G      Meas. time: adjustable
                     Intrinsic safety                                                 Ampl. range Adjustable, fixed or autorange
                          EEx em ib IIC T4: TÜV 01 ATEX 1699                       Measurement setups
                     Temperature range                                                Predefined, knowledge based measurement
                        Operation     0... +45°C / 32...113°F                         setups for machines, bearing and gear diagno-
                        Storage      -20... +45°C / -4...113°F                        sis;
                                                                                      Freely selectable multimeter measurement
                     Electrical data                                                  functions;
                      Digital output circuit
                          in type of protection intr. safety EEx ib IIC            User interface
                          only suitable for the connection to devices                  Graphic-oriented and cursor controlled:
                          intended for this                                                 Icons for measurement tasks;
                          U0 10,1 V                                                         Machine pictures for measurement
                          I0    55 mA                                                       location scanning;
                          Ci 330 nF                                                         Graphic route guide;
                          C0 370 nF                                                    Integrated help function
                          L0 0.5 mH                                                Units
                      Analog output circuit                                            ISO and US units, switchable
                         in type of protection intr. safety EEx ib IIC
                         only suitable for the connection to devices               Comments
                         intended for this                                            User-defined events with comments
                         U0 12 V                                                   Language
                         I0    36 mA                                                   English, German, French, Italian
VIBSCANNER 09.2003
                         P0 200 mW
                         Ci 31 nF
                         C0 1410 nF
                         L0 31 mH
                       Temperature sensor circuit
                         in type of protection intr. safety EEx ib IIC             *CLD: Current line drive (amplifier with current output)
                         only suitable for the connection to NiCr-Ni-              ** no power supply
                         thermocouple
72
Troubleshooting
                  Troubleshooting
                  • Symptom:
                  After the power has been switched on, the blue LED flashes
                  slowly.
                  Meaning:
                  The device is in boot mode. This can have two reasons:
                  1. Boot mode was manually entered by the user
                  2. The application firmware is missing or corrupted.
                  What to do:
                  If the battery charger is connected to the device, disconnect
                  it.
                  Reset the device.
                  If the device still goes into boot mode, update the firmware
                  using the VIBSCANNER update tool.
                  • Symptom:
                  When switching on the device, the red LED flashes quickly
                  for approx. 1 second.
                  Meaning:
                  The rechargeable battery is empty.
                  What to do:
                  Charge the battery.
                  FOR SERVICE ONLY: the battery check during power on
                  can be bypassed by pressing the left button (ESC key)
                  during power on.
                  • Symptom:
                  When switching on the device the backlight of the displays
                  lights up but nothing appears on the display.
                  Meaning:
                  The software is not running properly.
                  What to do:
                  Reset the device.
                  If this doesn’t work, update the firmware using the VIB-
                  SCANNER update tool.
                                                                                  VIBSCANNER 09.2003
                                                                                                   73
                                                                                      Troubleshooting
                     • Symptom:
                     Battery does not charge (red LED on the battery does not
                     light up) when the charger is connected and VIBSCANNER
                     is switched off.
                     Meaning:
                     VIBSCANNER erroneously sends a starting signal to the
                     battery.
                     What to do:
                     Remove the battery from VIBSCANNER and charge it
                     separately.
                     • Symptom:
                     Charging process in the case of a deeply discharged battery
                     terminates prematurely (5min – 1h), green LED lights up
                     on the battery.
                     Meaning:
                     Deeply discharged battery.
                     What to do:
                     Switch on VIBSCANNER without the charger connected
                     and leave it switched on until the battery is empty again
                     and the instrument switches off by itself. Then repeat the
                     charging process. If necessary, charge the battery separate-
                     ly.
                     • Symptom:
                     Charging process does not start, red LED on the storage
                     battery flashes continuously (>20min).
                     Meaning:
                     Error condition identified during the charging process, or
                     battery defective.
                     What to do:
                     Ambient temperature 10–40°C? Discharge the battery
                     again. Charge the battery separately. If charging is still not
                     possible, return the battery for repair.
                     • Symptom:
                     “Battery level inaccurate” appears when switching off or
VIBSCANNER 09.2003
                                   ** Filesystem Error **
                                              Media status == ....
                                              Volume == .....
                                              Serial # == ....
                                              Volume is ....
                                              .....
                                   ** Select Action **
                                   Format               Abort
                  Meaning:
                  A serious error occurred while accessing the internal
                  VIBSCANNER hard disc.
                  What to do:
                  Try to abort the current action by pressing the right button
                  (function key).
                  If this doesn’t help, try to reset the device.
                  If this doesn’t help, try to format the VIBSCANNER hard
                  disc by pressing the left button (ESC key). Formatting the
                  hard disc may take a few minutes.
                  If the format is successful, all files on the VIBSCANNER are
                  deleted. In order to restore these files, use the VIBSCAN-
                  NER UpdateTool and download the files by choosing the
                  ‘Filetransfer’ button in step 4. Make sure that you download
                  the files from the same firmware version as that already on
                  the VIBSCANNER.
                  If the format is not successful, return the device for repair.
                  Meaning:
                                                                                   VIBSCANNER 09.2003
                     Meaning:
                     A serious error occurred while accessing the internal
                     VIBSCANNER hard disc.
                     What to do:
                     Retry the current action by pressing the left button (ESC
                     key). If this doesn’t help, try to abort by pressing the right
                     button (function key). If this doesn’t help, clear the current
                     action by pressing the joystick. If this doesn’t help, try to
                     reset the device.
                     If the problem persists, return the device for repair.