Extra Low Temperature Heating
Wall Mounted High-SEER 9, 12 and 15,000 BTU Systems
SYSTEMS 9RLS2H, 12RLS2H, 15RLS2H
Up to 27.2 SEER
High Performance Heating
Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor. Rated heating capacity is maintained up to 20F. RLS2H models can operate down to -15F.
9,000 BTU/h Model
(MBH) (MBH) 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 40 30 20 10 0 -5 (F) -15 -20 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 40 30 20 10 0 -5 (F) -15 -20
12,000 BTU/h Model
(MBH) 35.0 30.0 25.0 20.0 15.0 10.0 5.0 0.0 40
15,000 BTU/h Model
15RLS2H
Heating Capacity
Heating Capacity
Heating Capacity
9RLS2H
12RLS2H
30
20
10
0 -5 (F)
-15 -20
Outdoor Temperature
Outdoor Temperature
Outdoor Temperature
Energy Saving Program
ESP knows how to save you money even when you forget. If you leave the room without turning the unit off, ESP knows that you left and 20 minutes later, set temperature is increased by 4F when cooling and reduced by 8F when heating. When you come back to the room, it returns to previous operating mode. This prevents wasteful operation to save energy without you having to think about it.
Standard Features
l l l l l l l l l
Wireless Remote Control Sleep Timer BasePan Heater Dry Mode Auto Louver: Up/Down Auto Mode Quiet Mode (Indoor) Economy Mode Low Noise Mode (Outdoor)
l l l l l l l l
Energy Saving Program Program Timer/ Weekly Timer Auto Restart/Reset Auto Changeover* Low Ambient Heating Apple Catechin Filter Ion Deodorizing Filter Powerful Operation Mode
SAVE!
Set Temp.
Optional Accessories
AUTO RESTART
+4F *Max. 86F
NEW
l l l l
Wired Remote Controller: UTY-RVNUM
Backlit and includes room temperature!
Cooling/Dry
Set Temp.
Judgment (20 min.)
Judgment (20 min.)
-8F *Max. 60F
Wired Remote Controller: UTY-RNNUM Simple Remote Controller: UTY-RSNUM Communication Kit: UTY-TWBXF
UTY-RVNUM
Heating
Normal Operation
Saving Operation Normal Operation
*Auto Changeover (Heating to Cooling or Vice Versa) automatically alternates between heating or cooling if the room temperature falls 4F below the set temperature when cooling or rises 4F above set temperature when heating. Auto changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling.
9RLS2H 12RLS2H 15RLS2H
HeatPump HeatPump HeatPump
Base Freeze Prevention
l l l Equipped with a base heater that prevents condensate from freezing Cultivated base design discharges melted water through many holes. Without a heater, freezing condensate can cause noise, damage to fan blade, condenser, Drain Holes and system performance.
Fujitsu RLS2H Competitor M
Base Heater
Competitor P
Drain hole is not filled, Freezing where there no freezing of base is no heater
Drain hole is closed, large freezing of base
Condition: Indoor temp. of 68FDB / outdoor temp. of 5FDB, Heating mode, High airflow volume. Operation for 24 hours.
Slim &Compact
Up to 25% slimmer than the competing units.
INDOOR UNIT DIMENSIONS
11-1/8
2-3/16 4 or more
34-1/4
7-1/4
OUTDOOR UNIT DIMENSIONS
3/4 31-3/32
2-7/16 11-13/32
Nominal Cooling BTU/h Min.~Max. Cooling BTU/h Nominal Heating BTU/h Min.~Max. Heating BTU/h HSPF BTU/hW SEER BTU/hW EER Clg/Htg Clg. Operating Range F(C) Htg. Operating Range F(C) Moisture Removal Pt./h(l/h) Voltage/Frequency/Phase Recommended Fuse Size (A) Air Circ. C.F.M. (m3/h): Hi Medium Low Quiet Noise Level dB(A): Hi Medium Low Quiet Outdoor Fan Speed RPM Clg/Htg Outdoor Noise Level dB(A) Current Rated (A):Cooling Heating Power Use Rated (kw):Cooling Heating Fan Speeds Stage Air Direction: Horizontal Vertical Air Filter Apple Catechin Filter Connection Method Combined Max. Lgth Ft (m) Max. Vertical Diff. Ft (m) Conn. Pipe Diameter Inch Net Weight lbs. (kg) Dimensions: Height Inch
9,000
12,000
12,000
16,000
14,500
3,100~18,400 18,000 3,100~23,900 10.3
3,100~12,000 3,100~13,600 3,100~22,000 3,100~22,100
8.8 27.2 16.1/15.0
9.3 25.0 13.8/13.3
21.5 12.0/13.3
14~115 (-10~46) 14~115 (-10~46) 14~115 (-10~46) -15~75 (-26~24) -15~75 (-26~24) -15~75 (-26~24)
Base
4.44 (2.1) 2.75 (1.3) 3.8 (1.8) 208-230/60/1 208-230/60/1 208-230/60/1 15 15 20 500 (850) 500 (850) 530 (900) 394 (670) 394 (670) 436 (740) 324 (550) 324 (550) 336 (570) 194 (330) 194 (330) 229 (390) 43/43 43/43 45/45 37/38 37/38 40/40 32/32 32/32 33/34 21/21 21/21 25/27 780/780 870/780 870/780 48/49 2.7 3.7 .56 .80 4+Auto Manual Auto Washable Yes Flare 66 (20) 49 (15) 49/50 4.0 5.5 .87 1.20 4+Auto Manual Auto Washable Yes Flare 66 (20) 49 (15) 51/51 5.5 6.1 1.21 1.35 4+Auto Manual Auto Washable Yes Flare 66 (20) 49 (15)
Drain Hole
13-1/4
Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4 Suc. 1/2 Dis. 1/4 21 (9.5) 88 (40) 21 (9.5) 88 (40) 21 (9.5) 88 (40)
11-1/8 13-1/4*
24-1/2
24-1/2
11-1/8 13-1/4*
24-1/2
11-1/8 13-1/4*
24-1/2
13-7/8
620 282/337* 620 Width Inch 34-1/4 31-3/32 34-1/4 31-3/32 34-1/4 31-3/32 870 790 870 790 870 790 mm Depth Inch 7-1/4 11-13/32 7-1/4 11-13/32 7-1/4 11-13/32 185 185 185 290 290 290 mm R410A R410A R410A Refrigerant
282/337*
mm 282/337* 620
3/4
Outdoor AOU12RLS2H
Outdoor AOU9RLS2H
The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon logo and name is a trademark of Fujitsu General America, Inc. ENERGYSTAR is a registered trademark of the EPAand DOE. Copyright 2013 Fujitsu General America, Inc. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. Fujitsus products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information without notice and without incurring any obligations.
Note: Figures are based on 230 Volts. *Height when front panel is open.
FUJITSU GENERAL AMERICA, INC. 353 Route 46 West Fairfield, NJ 07004 Tel: (973) 575-0380 Fax: (973) 836-0448 w w w. f u j i t s u g e n e r a l . c o m
Part #6-26-FG2041 Rev. 1/13
Outdoor AOU15RLS2H
Indoor ASU9RLS2
Indoor ASU12RLS2