FORM NO. G11-442 REV.
6
Supersedes Form No. G11-442 Rev. 5
GAS FURNACES
CRITERION II
78% A.F.U.E.
UPFLOW GAS
FURNACES
The Rheem Criterion II line of upflow gas furnaces are
designed for utility rooms, closets, or alcoves. Because of
the Criterions low-profile 34 inch [864 mm] height, the
upflow model installed vertically can also be used to
satisfy most applications that traditionally call for a
horizontal furnace.
The design is certified by the American Gas Association.
Canadian models are certified by the Canadian Gas
Association.
Features
Patented Turbulex Heat Exchanger, constructed of both
stainless and aluminized steel for the maximum in corrosion resistance.
Low profile 34 inch [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
Standing pilot ignition system models only.
Left or right side gas and electric inlet connections with
quick, simple change.
An accessory kit is available for humidifier and electronic
air cleaner hook-ups.
Insulated blower compartment, a slow-open gas valve and
a specially designed draft inducer motor make it one of the
quietest induced draft furnaces on the market today.
Pre-paint galvanized steel cabinet.
Grab-holes in doors to aid in easy door removal and
replacement.
Improved filter access/removal.
Permanent washable filter.
A variety of cooling coils and plenums designed to use with
Rheem Criterion II gas furnaces are available as optional
accessories.
RGDG- SERIES
Standing Pilot Models
with Input Rates from
45,000 to 150,000 BTU/HR
[13 to 44 kW]
(U.S. & Canadian Models)
ENER
UIDE
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
78.0%
MID
78%
82%
HIGH
88%
97%
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
RHEEM CRITERION II 78%
UPFLOW GAS FURNACE
Turbulex Heat Exchanger
Draft Inducer Motor
In-Shot Burners
and Gas Valve
Blower and
Control Box
Integrated
Furnace
Control
STANDARD EQUIPMENT
Completely assembled and wired; induced draft; pressure switch; redundant main
gas control; blower compartment door safety switch; solid state time on/time off
blower control; limit control; manual shut-off valve, pressure regulator for natural
and L.P. (propane) gas; transformer; direct drive multi-speed blower motor.
Furnaces are equipped with cooling/heating relay and transformer (40VA) ready
for air conditioning applications. (Please note: a thermostat is not included as
standard equipment.) Standing pilot models may not be twinned; fused transformer (secondary).
OPTIONAL EQUIPMENT
External filter frame assemblies. Return air cabinet for all sizes. Solid bottom
(See Page 6)
NOTE: Furnace is not listed for use with fuels other than natural or L.P.
(propane) gas.
Molded Permanent Filter
Pilot Assembly
(Standing Pilot Models)
All models can be converted by a qualified Rheem distributor or local service dealer
to use L.P. (propane) gas without changing burners. Factory approved kits must be
used to convert from natural to L.P. (propane) gas and may be ordered as optional
accessories from a Rheem parts distributor.
For L.P. (propane) operation, refer to Conversion Kit Index Form No. 92-21519-52
for U.S. models and Form No. 92-21519-53 for Canadian models.
WARNING
THIS FURNACE IS NOT APPROVED
OR RECOMMENDED
FOR USE IN MOBILE HOMES
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
PHYSICAL DATA AND SPECIFICATIONSU.S. MODELS (UPFLOW)
MODEL NUMBERS
RGDG- SERIES
045AUSR
04MAUSR
050AUER
05MAUER
067AUER
06MAUER
075AUER
07MAUER
075AMGR
07MAMGR
100AUER
10MAUER
45,000 [13]
Heating Capacity BTU/Hr [kW] 36,000 [11]
Heat Ext. Static Pressure [kPa]
.10 [.025]
50,000 [15]
41,000 [12]
67,500 [20]
54,000 [16]
75,000 [22]
60,000 [18]
75,000 [22]
60,000 [18]
100,000 [29]
80,000 [23]
.10 [.025]
.12 [.029]
.12 [.029]
.12 [.029]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
11 x 7
[279 x 178]
.15 [.037]
11 x 6 = 10*AU
[279 x 152]
11 x 7 = 10*AM
[279 x 178]
Motor H.P.Speeds
PSC Type [W]
1/2-4-PSC
1/2-4-PSC
1/2-4-PSC
1/2-4-PSC
3/4-4-PSC
[373]
[373]
[373]
[373]
[559]
Motor Full Load Amps
Heating Speed
7.1
MED-LOW
6.8
MED-LOW
7.1
MED-HIGH
7.1
MED-HIGH
Cooling Speed
HIGH
HIGH
HIGH
Cooling CFM @ .5" E.S.P.
(Nominal) [L/s]
1200
[566]
1200
[566]
Rated E.S.P. (In. W.C.) [kPa]
.50 [.12]
Temperature Rise Range F
[C]
Input-BTU/Hr [kW]
Blower (D x W) [mm]
Max. Outlet Air Temp. F
[C]
Standard Permanent High
Velocity Filter In. [mm]
Approx. Shipping Weight (Lbs.)
[kg]
Return Air Cabinets
(Opt.) RXGRFilter Size [mm]
AFUEStanding Pilot Models
100BRJR
10MBRJR
125ARJR
12MARJR
150ARJR
15MARJR
100,000 [29] 125,000 [37] 150,000 [44]
81,000 [24] 99,000 [29] 119,000 [35]
.15 [.037]
.20 [.05]
.20 [.05]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
1/2-4-PSC
3/4-4-PSC
3/4-4-PSC
3/4-4-PSC
[373]
[559]
[559]
[559]
9.5
MED-LOW
7.1
MED-HIGH
9.5
MED-LOW
9.5
MED-LOW
9.5
MED-LOW
HIGH
MED-HIGH
HIGH
1200
[566]
1200
[566]
1600
[755]
1200
[566]
MED-HIGH
MED-HIGH
1845 [871]
MED-HIGH
MED-HIGH
1885 [890]
MED-HIGH
MED-HIGH
1850 [873]
HIGH
2060 [922]
HIGH
2115 [998]
HIGH
2080 [982]
.50 [.12]
.50 [.12]
.50 [.12]
.50 [.12]
.50 [.12]
.50 [.12]
.50 [.12]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
30-60
[16.7-33.3]
40-70
[22.2-38.9]
25-55
[13.9-30.6]
.50 [.12]
55-85 = 10*AU
[30.6-47.2]
50-80 = 10*AM
[27.8-44.4]
40-70
[22.2-38.9]
35-65
[19.4-36.1]
50-80
[27.8-44.4]
165
[73.8]
155
[68.3]
165
[73.8]
165
[73.8]
155
[68.3]
190
[87.7]
170
[76.6]
180
[82.2]
190
[87.7]
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
78.2%
153/4 x 25
[400 x 635]
85
[39]
C14B
(2) 12 x 16
[305 x 406]
78.7%
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
78.2%
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
78.7%
153/4 x 25
[400 x 635]
105
[48]
C17B
(2) 12 x 16
[305 x 406]
78.6%
153/4 x 25
[400 x 635]
115
[52]
C17B
(2) 12 x 16
[305 x 406]
78%
191/4 x 25
[489 x 635]
120
[54]
C21B
(2) 20 x 16
[508 x 406]
78.3%
223/4 x 25
[578 x 635]
140
[63]
C24B
(2) 24 x 16
[610 x 406]
78.2%
223/4 x 25
[578 x 635]
150
[68]
C24B
(2) 24 x 16
[610 x 406]
78.1%
NOTES: All models are 115V, 60HZ, 1. Gas connection size for all models is 1/2" [12 mm] N.P.T.
In accordance with D.O.E. test procedures.
[
] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
Gas Heat Exchanger Limited Warranty .......Twenty (20) Years
Draft Inducer Limited Warranty ........................Five (5) Years
Blower Control Board Limited Warranty ............Five (5) Years
Any Other Part.................................................One (1) Year
*For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
PHYSICAL DATA AND SPECIFICATIONSCANADIAN MODELS (UPFLOW)
MODEL NUMBERS
RGDG- SERIES
045AUSA
050AUEA
067AUEA
075AUEA
075AMGA
100AUEA
45,000 [13]
36,000 [11]
50,000 [15]
41,000 [12]
67,500 [20]
54,000 [16]
75,000 [22]
59,500 [17]
75,000 [22]
60,000 [18]
100,000 [29]
80,000 [23]
100,000 [29] 125,000 [37] 150,000 [44]
81,000 [24] 99,000 [29] 119,000 [35]
40,500 [12]
45,000 [13]
60,800 [18]
67,500 [20]
67,500 [20]
90,000 [26]
90,000 [26] 112,500 [33] 135,000 [40]
32,000 [9]
36,500 [11]
48,500 [14]
54,000 [16]
54,000 [16]
72,000 [21]
72,500 [21]
.10 [.025]
.10 [.025]
.12 [.029]
.12 [.029]
.12 [.029]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
11 x 6
[279 x 152]
Motor H.P.Speeds
PSC Type [W]
1/2-4-PSC
1/2-4-PSC
1/2-4-PSC
1/2-4-PSC
3/4-4-PSC
[373]
[373]
[373]
[373]
[559]
Motor Full Load Amps
Heating Speed
7.1
MED-LOW
6.8
MED-LOW
7.1
MED-HIGH
7.1
MED-HIGH
Cooling Speed
HIGH
HIGH
HIGH
Cooling CFM @ .5" E.S.P.
(Nominal) [L/s]
1200
[566]
1200
[566]
.50 [.12]
.50 [.12]
Input-BTU/Hr [kW]
Heating Capacity BTU/Hr [kW]
High Altitude Input [kW]
High Altitude Output
Capacity [kW]
Heat Ext. Static Pressure [kPa]
Blower (D x W) [mm]
Rated E.S.P. (In. W.C.) [kPa]
.15 [.037]
11 x 6 = 10*AU
[279 x 152]
11 x 7
[279 x 178] 11 x 7 = 10*AM
[279 x 178]
100BRJA
125ARJA
150ARJA
89,000 [26] 107,000 [31]
.15 [.037]
.20 [.05]
.20 [.05]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
11 x 10
[279 x 254]
1/2-4-PSC
3/4-4-PSC
3/4-4-PSC
3/4-4-PSC
[373]
[559]
[559]
[559]
9.5
MED-LOW
7.1
MED-HIGH
9.5
MED-LOW
9.5
MED-LOW
9.5
MED-LOW
HIGH
MED-HIGH
HIGH
1200
[566]
1200
[566]
1600
[755]
1200
[566]
.50 [.12]
.50 [.12]
.50 [.12]
.50 [.12]
MED-HIGH
MED-HIGH
1845 [871]
HIGH
2060 [922]
.50 [.12]
MED-HIGH
MED-HIGH
1885 [890]
HIGH
2115 [998]
.50 [.12]
MED-HIGH
MED-HIGH
1850 [873]
HIGH
2080 [982]
.50 [.12]
40-70
[22.2-38.9]
35-65
[19.4-36.1]
50-80
[27.8-44.4]
35-65
[19.4-36.1]
25-55
[13.9-30.6]
30-60
[16.7-33.3]
40-70
[22.2-38.9]
25-55
[13.9-30.6]
55-85 = 10*AU
[30.6-47.2]
50-80 = 10*AM
[27.8-44.4]
Max. Outlet Air Temp. F
[C]
165
[73.8]
155
[68.3]
165
[73.8]
165
[73.8]
155
[68.3]
190
[87.7]
170
[76.6]
180
[82.2]
190
[87.7]
Standard Permanent High
Velocity Filter In. [mm]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
153/4 x 25
[400 x 635]
191/4 x 25
[489 x 635]
223/4 x 25
[578 x 635]
223/4 x 25
[578 x 635]
85
[39]
85
[39]
105
[48]
105
[48]
105
[48]
115
[52]
120
[54]
140
[63]
150
[68]
C14B
(2) 12 x 16
[305 x 406]
78.2%
C14B
(2) 12 x 16
[305 x 406]
78.7%
C17B
(2) 12 x 16
[305 x 406]
78.2%
C17B
(2) 12 x 16
[305 x 406]
78.7%
C17B
(2) 12 x 16
[305 x 406]
78.6%
C17B
(2) 12 x 16
[305 x 406]
78%
C21B
(2) 20 x 16
[508 x 406]
78.3%
C24B
(2) 24 x 16
[610 x 406]
78.2%
C24B
(2) 24 x 16
[610 x 406]
78.1%
Temperature Rise Range F
[C]
Approx. Shipping Weight (Lbs.)
[kg]
Return Air Cabinets
(Opt.) RXGRFilter Size [mm]
AFUEStanding Pilot Models
NOTES: All models are 115V, 60HZ, 1. Gas connection size for all models is 1/2" [12.7 mm] N.P.T.
In accordance with D.O.E. test procedures.
See Conversion Kit Index Form No. 92-21519-53 for high altitude derate.
MODEL IDENTIFICATIONUPFLOW MODELS
R
Rheem
Gas
Furnace
Upflow
Design
Series
] Designates Metric Conversions
07E
Heating Input Designation
Variations
A = Std.
Cabinet
B = Wide
Cabinet
Blower
Designation
U = 11 x 6
[279 x 152 mm]
M = 11 x 7
[279 x 178 mm]
R = 11 x 10
[279 x 254 mm]
Heating & Cooling
Designation
S = 500-1200 CFM
[236-566 L/s]
E = 1100-1330 CFM
[519-628 L/s]
G = 1450-1750 CFM
[684-826 L/s]
J = 1800-2075 CFM
[850-979 L/s]
Fuel Type
R = Natural Gas,
U.S. Standard
Furnace
A = Natural Gas,
Canadian
Standard
Furnace
Standing
Pilot
NOx
Model
Input
BTU/HR
045
050
067
075
100
125
150
04M
05M
06M
07M
10M
12M
15M
45,000 [13 kW]
50,000 [15 kW]
67,500 [20 kW]
75,000 [22 kW]
100,000 [29 kW]
125,000 [37 kW]
150,000 [44 kW]
UPFLOW DIMENSIONS
TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]
REDUCED CLEARANCE (IN.) [mm]
MODEL
RGDG-
04, 05
06, 07
10 (A)
10 (B)
12
15
141/2 [356]
171/2 [445]
171/2 [445]
211/2 [533]
241/2 [622]
241/2 [622]
1227/32 [326]
1611/32 [415]
1611/32 [415]
1927/32 [504]
2311/32 [593]
2311/32 [593]
103/8 [263]
121/8 [308]
121/8 [308]
137/8 [352]
155/8 [397]
155/8 [397]
111/2 [292]
151/2 [381]
151/2 [381]
181/2 [470]
221/2 [559]
221/2 [559]
LEFT
SIDE
0
0
0
0
0
0
RIGHT
SIDE
BACK
TOP
FRONT
VENT
4 [102]
3 [76]
3 [76]
0
0
0
0
0
0
0
0
0
1 [25]
1 [25]
1 [25]
1 [25]
1 [25]
1 [25]
3 [76]
3 [76]
3 [76]
3 [76]
3 [76]
3 [76]
6 [152]
6 [152]
6 [152]
6 [152]
6 [152]
6 [152]
SHIP. WGTS.
(LBS.) [kg]
85 [38.56]
105 [47.63]
115 [52.16]
120 [54.43]
140 [63.50]
150 [68.04]
NOTES: Vent diameter connection as shipped from the factory is 3" [76 mm]. Certain installations will require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to
5" [127 mm] adapter.
May be 0" with type B vent.
May be 1" [25 mm] with type B vent.
Furnaces must be vented in accordance with ANSI Z21.47-1993 CAN/CGA-2.3-M93 Category I venting table guidelines in accordance with local codes, or
the National Fuel Gas Code.
[
] Designates Metric Conversions
ACCESSORIESUPFLOW
PLENUM DATA FOR A COILS
ACCESSORY RETURN
AIR CABINETS
Return Air Cabinets may be
installed on rear or either side
application except RXGR-C24B
(side application must be
on side opposite gas and
electrical connections).
Plenum adapters are required in some instances for use on upflow applications
when plenum and furnace size do not match.
FURNACE
WIDTH
IN. [mm]
141/2 [356]
141/2 [356]
171/2 [445]
171/2 [445]
171/2 [445]
171/2 [445]
211/2 [533]
211/2 [533]
211/2 [533]
241/2 [622]
241/2 [622]
PLENUM
WIDTH
IN. [mm]
161/4 [413]
201/4 [514]
161/4 [413]
201/4 [514]
215/8 [549]
251/4 [641]
251/4 [641]
221/4 [565]
215/8 [549]
251/4 [641]
215/8 [549]
PLENUM ADAPTER
UPFLOW
COIL
PLENUM
RXAA-C171
RXAA-C172
RXAA-C185
RXAA-C173
RXAA-C187
RXAA-C174
RXAA-C175
RXAA-C176
RXAA-C188
RXAA-C177
RXAA-C187
RXAL-B16BU
RXAL-B20BU
RXAL-B16BU
RXAL-B20BU
RXAL-B21BU
RXAL-B25BU
RXAL-B25BU
RXAL-B22BU
RXAL-B21BU
RXAL-B25BU
RXAL-B21BU
Note: See Form Number C11-206 for MultiFlex coil data.
SOLID BOTTOM OPTION: Factory installed solid bottom.
Use option code 263.
EXTERNAL SIDE RETURN FILTER RACK: RXGF-CA
EXTERNAL BOTTOM RETURN FILTER RACK FOR
UPFLOW APPLICATION: RXGF-CB
FILTER RACK FILTER SIZES INCHES [mm]
MODEL
RXGF-CA
RGDG(SIDE)
153/4 x 25
04, 05, 06, 07, 100A
[400 x 635]
153/4 x 25
100BRJ
[400 x 635]
153/4 x 25
12, 15
[400 x 635]
THE RXGR-C24B MAY ONLY BE INSTALLED
ON REAR AND LEFT SIDES.
RETURN AIR CABINETS
RXGR-C14B
RXGR-C17B
RXGR-C21B
RXGR-C24B
Filter racks are shipped without filters.
Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.
A
IN. [mm]
141/4 [356]
171/2 [445]
211/4 [533]
241/2 [622]
B
IN. [mm]
1227/32 [326]
1611/32 [415]
1927/32 [504]
2311/32 [593]
FILTER SIZE
IN. [mm]
(2) 12 x 16 [305 x 406]
(2) 12 x 16 [305 x 406]
(2) 20 x 16 [508 x 406]
(2) 24 x 16 [610 x 406]
RXGW-AAA01
Humidifier and Electronic Air Cleaner Accessory Board for
Robertshaw Control RBC1 and Honeywell ST9101A 1014
Blower Controls.
NOTE: Available for standing pilot models only.
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE
IS INSTALLED WITH SIDE OR REAR AIR RETURN DUCTS. FAILURE TO INSTALL A
BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO
THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. SOLID
BOTTOM IS AVAILABLE FACTORY INSTALLED WITH OPTION CODE 263.
RXPF-F01 and F02
FOSSIL FUEL KITis for use with Rheem Heat Pumps and
Criterion warm air furnaces. RXPF-F02 meets TVA requirements.
[
FURNACE
WIDTH
IN. [mm]
SOLID BOTTOM
KIT NO.
BASE
PLATE NO.
BASE
PLATE SIZE
IN. [mm]
141/2 [356]
171/2 [445]
211/2 [533]
241/2 [622]
RXGB-D14
RXGB-D17
RXGB-D21
RXGB-D24
AE-61874-01
AE-61874-02
AE-61874-03
AE-61874-04
115/8 x 239/16 [295 x 598]
151/8 x 239/16 [384 x 598]
185/8 x 239/16 [473 x 598]
255/8 x 239/16 [651 x 598]
] Designates Metric Conversions
BLOWER PERFORMANCE DATAUPFLOW MODELS
MODEL
NUMBER
RGDGSERIES
BLOWER
SIZE
[mm]
MOTOR
H.P.
[W]
045AUS*
04MAUSR
11 x 6
[279 x 152]
1/2
[373]
050AUE*
05MAUER
11 x 6
[279 x 152]
1/2
[373]
067AUE*
06MAUER
075AUE*
07MAUER
11 x 6
[279 x 152]
1/2
[373]
075AMG*
07MAMGR
11 x 7
[279 x 178]
3/4
[559]
100AUE*
10MAUER
11 x 6
[279 x 152]
1/2
[373]
100BRJ*
10MRJR
11 x 10
[279 x 254]
3/4
[559]
125ARJ*
12MARJR
11 x 10
[279 x 254]
3/4
[559]
150ARJ*
15MARJR
11 x 10
[279 x 254]
3/4
[559]
BLOWER
SPEED
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
LOW
MED-LO
MED-HI
HIGH
CFM [L/s] AIR DELIVERY
EXTERNAL STATIC PRESSURE INCHES [kPa] WATER COLUMN
.1 [.02]
.2 [.05]
.3 [.07]
.4 [.10]
.5 [.12]
.6 [.15]
.7 [.17]
650 [307]
935 [441]
1140 [538]
1315 [621]
675 [319]
950 [448]
1115 [526]
1270 [599]
820 [387]
970 [458]
1110 [524]
1265 [597]
1245 [588]
1555 [734]
1810 [854]
2050 [967]
1005 [474]
1150 [543]
1300 [614]
1295 [611]
1645 [776]
2045 [965]
2320 [1095]
1280 [604]
1645 [776]
2050 [967]
2365 [1116]
1270 [599]
1620 [765]
2010 [949]
2340 [1104]
620 [293]
905 [427]
1105 [522]
1275 [602]
655 [309]
930 [439]
1090 [514]
1250 [590]
800 [378]
955 [451]
1090 [514]
1240 [585]
1220 [576]
1515 [715]
1755 [828]
1985 [937]
980 [463]
1120 [529]
1280 [604]
1275 [602]
1615 [762]
2000 [944]
2260 [1067]
1275 [602]
1635 [772]
2015 [951]
2310 [1090]
1250 [590]
1595 [753]
1985 [937]
2275 [1074]
585 [276]
870 [411]
1065 [503]
1230 [580]
635 [300]
905 [427]
1070 [505]
1225 [578]
780 [368]
940 [444]
1070 [505]
1210 [571]
1195 [564]
1475 [696]
1705 [805]
1915 [904]
955 [451]
1055 [498]
1255 [592]
1250 [590]
1580 [746]
1955 [923]
2200 [1038]
1265 [597]
1615 [762]
1980 [934]
2250 [1062]
1220 [576]
1570 [741]
1960 [925]
2215 [1045]
550 [260]
835 [394]
1025 [484]
1195 [564]
610 [288]
880 [415]
1040 [491]
1200 [566]
755 [356]
910 [429]
1040 [491]
1175 [555]
1165 [550]
1435 [677]
1645 [776]
1845 [871]
930 [439]
1060 [500]
1225 [578]
1225 [578]
1550 [732]
1905 [899]
2130 [1005]
1245 [588]
1590 [750]
1935 [913]
2185 [1031]
1195 [564]
1545 [729]
1915 [904]
2145 [1012]
510 [241]
795 [375]
980 [463]
1155 [545]
585 [276]
860 [406]
1015 [479]
1165 [550]
730 [345]
880 [415]
1010 [477]
1140 [538]
1135 [536]
1395 [658]
1585 [748]
1785 [842]
900 [425]
1040 [491]
1185 [559]
1195 [564]
1510 [713]
1845 [871]
2060 [972]
1215 [573]
1560 [736]
1885 [890]
2115 [998]
1165 [550]
1515 [715]
1850 [873]
2080 [982]
475 [224]
755 [356]
935 [441]
1120 [529]
555 [262]
830 [392]
985 [465]
1130 [533]
705 [333]
845 [399]
975 [460]
1100 [519]
1105 [522]
1350 [637]
1530 [722]
1715 [809]
865 [408]
1000 [472]
1145 [540]
1165 [550]
1465 [691]
1785 [842]
1985 [937]
1185 [559]
1520 [717]
1835 [866]
2035 [960]
1135 [536]
1480 [698]
1800 [850]
2010 [949]
435 [205]
715 [337]
885 [418]
1085 [512]
520 [245]
800 [378]
945 [446]
1085 [512]
675 [319]
805 [380]
935 [441]
1055 [498]
1065 [503]
1300 [614]
1470 [694]
1655 [781]
830 [392]
955 [451]
1095 [517]
1135 [536]
1425 [673]
1720 [812]
1910 [901]
1145 [540]
1470 [694]
1775 [838]
1950 [920]
1105 [522]
1440 [680]
1730 [816]
1940 [916]
NOTES: **Designates R for U.S. models and A for Canadian models.
**Not to be used as a heating speed.
**Data compiled with factory filter installed.
[
] Designates Metric Conversions
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
RHEEM
AIR CONDITIONING
DIVISION
P.O. Box 17010, Fort Smith, Arkansas 72917-7010
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A.
11-96 DC
FORM NO. G11-442 REV. 6
Supersedes Form No. G11-442 Rev. 5