Specification
Variable Area Flowmeters
Series 10A4500
Main Menu
Rugged body design with all type 300
stainless steel construction
Metering tube can be removed for range
change or cleaning in O-ring or packing type
with meter in line and without disassembly
of meter.
Polycarbonate operator protection shield
designed to protect personnel from glass
fragments in the event of accidental tube
rupture
Universal threaded process connections
Screw-on flanges
Rotatable end fittings
Visibility of tube and float through wide
angle with standard enclosure & mounting
Series 10A4500
VA Master
Indicating Flowrator Meters
ABB Automation
S-FL/VA-10A4500_1
VA MASTER
INDICATING FLOWRATOR METERS
Electrical Specifications for Alarms
The Fischer & Porter Series VA Master Flowrator
meter is a glass tube variable-area flowmeter
providing visual indication of flow rate over a 12-1/2 to
1 range on a linear scale. Seals in the meter can be
either O-ring or packing gland type to suit the
application.
Contact Rating: Max. 250V; Max. 4A; Max. 500VA
Supply Voltage: 120V ac 15%, 45-65 Hz
Sensor Switch Cable:
Standard - 6.5 feet
Optional - up to 980 feet
Safety Classification: The sensor(s) is intrinsically safe
for Class I, Div. 1, Group A, B, C & D and Class II, Div.
1, Group E, F & G when connected with control amplifier mounted in non-hazardous location.
With either type of seal, the glass meter tube can be
removed easily for range change or cleaning, without
disassembling the end fittings or removing the meter
from the line. Both types have the same external
dimensions and are interchangeable with regard to
piping assembly. Also available with one or two
bistable alarms to give contact closure (or opening) on
rising or falling flow.
Service Conditions
Applications: Glass tube meters are not recommended
for continuous service on alkalis above 100F (38C)
or more than 20% concentrations; nor for fluorine, hydrofluoric acid, water above 200F (93C), steam, slurries, or molten metal.
Universal threaded process connections allow the
meter to be installed with either horizontal or vertical
piping arrangements. Screw-on flanges provide the
maximum in versatility.
Temperature Ratings: Minimum recommended process
fluid temperature is 32F (0C). Maximum recommended process fluid temperature is 250F (121C).
Ambient Temperature Range: 32F to 140F
The meter is available in tube sizes from 1/2-inch
through 2-inch bore for liquid or gas service.
Dimensions meet ISA Standard RP 16.1.2.3.
Pressure Ratings: (In accordance with I.S.A. RP 16.1)
Engineering Specifications
Repeatability: 0.5% of full scale.
Tube Size (inches)
Accuracy: Standard is 2% of maximum flow.
Calibrated standard is 1% of maximum flow.
Range: 12-1/2 to 1
NPT
Flanged; Stainless Steel
Flanged; Brass
All
1 All
1 All
2 All
Mounting: Standard line mounting;
Optional panel mounting (flush, surface).
Scales
T u b e S iz e s ,
In c h e s
S c a le
th ru 2
N o m in a l
L e n g th
1 0 -in . (2 5 0 m m )
-5 0 (o n ly )
9 -in . (2 2 7 m m )
T y p e a n d L o c a tio n
P e rc e n ta g e o n tu b e
o r D ire c t R e a d in g o n
e x te rn a l m e ta l s c a le
w ith b la n k tu b e
CAUTION
Is it important that the O-ring material be compatible whith the
process fluid. Meter tube breakage can occur if the wrong
material is used. For example: VITON O-RING MUST NEVER
BE USED FOR AMMONIA SERVICE.
Materials of Construction:
Tube: Beadguide borosilicate glass
USV, SV, NSV Floats: Standard - stainless steel;
O-rings: Standard - Buna N; Optional - Viton, EPR
Packing: Standard - Neoprene; Optional - molded
Teflon liner.
Fittings: Standard - brass, stainless steel
Float Stops: Teflon
Tube Rest Gaskets:
Standard - Klinger-Sil
Optional - Teflon (10A4600 only)
S-FL/VA-10A4500_1
Maximum Safe
Working Pressure
@ 100F (38C)
kPa
psig
gauge
300
2069
275
1896
225
1551
200
1379
200
1379
130
896
100
689
Weights and Connection
Tube
Size
(inches)
,1
,1
1 , 2
Conn.
Size
(inches)
NPT
1 Flgd
1
Threaded
Flanged*
Weight
lb
kg
lb
kg
8.5
3.9
12
5.5
17
7.5
----21
9.5
29
13
35
16
*Flanges match drilling of ANSI Class 125/150 Flanges
Meter Sizing
WARNING
For sizing flowmeters when the required flow is of liquid
(density 1.0 g/mL), or of gas (sp. gr. of air and at 14.7 psia
and 70F or 101.3 kPa abs and 21C) the capacity table
may be entered directly.
These meters must not be operated without the operator
protection shield in place. To do so could result in injury to
personnel.
The conversion equations shown permit the capacity
tables to be used for other operating conditions, and
apply to all Capacity Tables shown with Type 316 Stainless Steel Floats.
Accessories
Liquid Conversion
Alarms: One or two* bi-stable alarm switches,
adjustable over entire scale length to give contact
closure (or opening) upon rising or falling flow.
Available with SPDT or DPDT switch action.
Metal Scale Plate(s): Graduated metal scale plate
mounted adjacent to metering tube.
7.02 x
gpm H 2 O = gpm
8.02
or
gpm H 2 O =
lbs/min.
7.02 x
8.33 x
8.02
*Note when using two switches, the minimum spacing is on 1" centers
(approx. 10% of full scale).
Surface (Front) Panel Mounting: Nuts, bolts, and
lock washers for mounting meter against front of
panel by means of mounting holes provided in every
meter body.
where:
gpm =
lbs/min =
desired maximum flow rate in gpm
desired maximum flow rate in pounds per
minute
=
fluid density, g/cc at operating conditions
gpm H2O = equivalent flow rate in gpm H2O
Flush (Rear) Panel Mounting: Brackets, bezel and
hardware for mounting meter behind panel.
Gas Conversion
scfm air
at 14.7 psia
and 70F
= scfm
Welded Flanges: Upon request, flanges - nipples end fittings can be supplied as a welded assembly.
spgr x 14.7 x Top
1.0 x Pop x 530
Ordering Information
To eliminate any delays in the processing of orders
and to insure prompt delivery, please specify:
Complete Model Number
Accuracy Desired
Alarm Settings if applicable
Operating Conditions
Fluid Measured
Maximum Flow Rate and Unit of Flow
Fluid Density
Fluid Viscosity
Allowable Pressure Drop
Operating and Maximum Temperature
Operating and Maximum Pressure
or
scfm air
at 14.7 psia = lbs/min x 13.34
and 70F
1.0 x 14.7 x Top
sp gr x Pop x 530
Where:
scfm =
sp gr =
desired maximum flow rate in scfm
specific gravity of gas at standard
temperature and pressure, referenced to air
at standard temperature and pressure (14.7
psia and 70F)
Top =
absolute temperature, (460 +F) at operating
conditions
Pop =
absolute pressure in psia at operating
conditions
scfm air = equivalent flow rate in scfm of air at
14.7 psia and 70F with stainless steel float
S-FL/VA-10A4500_1
Capacity Table (Low Pressure Drop Design)
Tube Size
(Inch)
1/2
3/4
Maximum Flow
scfm Air
gpm H2O
Equiv.
Equiv.
0.198
0.800
0.238
0.982
0.324
1.339
0.436
1.796
0.825
3.40
0.633
2.62
0.860
3.54
1.205
4.98
1.67
6.90
2.58
10.70
3.60
14.84
2.45
10.30
3.33
13.80
6.50
27.00
8.70
36.00
5.54
22.90
13.75
56.70
Float Number
(316 sst)
Tube Number
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-27-G-10
FP-1/2-35-G-10
FP-1/2-50-G-9
FP-3/4-21-G-10
FP-3/4-27-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1 - 21-G-10
FP-1 - 27-G-10
FP-1 - 21-G-10
FP-1 - 27-G-10
FP-2-27-G-10
FP-2-27-G-10
1/2-GUSVT-410
3/4-GUVT-510
1-GUSVT-611
1-GUSVT-611
1-GUSVT-610
1-GUSVT-610
1 - GUSVT867
1 - GUSVT867
1 - GUSVGT-814
1 - GUSVGT-814
2-GUSVT-913
2-GUSVT-914
Total P
(See Note 1)
0.53
0.53
0.58
1.0
2.0
0.60
0.71
1.28
1.83
5.47
7.97
0.92
1.24
5.75
7.20
1.65
9.00
V.I.C.
(See Note 2)
psia Critical
(See Note 3)
2.2
3.6
3.3
4.00
4.00
8.6
8.6
6.5
6.5
16.2
16.2
8.9
22.0
3.1
1.5
1.0
0.75
4.5
3.4
1.0
1.0
6.8
6.8
1.0
6.2
Note: Standard percent scales are not applicable to low pressure drop floats.
Notes:
1. Pressure drop is total pressure loss across the meter at100% flow rate in inches of water column.
2. Meter is unaffected by viscosity when the value of cps/ r
(using r = operating density in g/cc and cps = viscosity in centipoises) is less than V.I.C. (viscosity
immunity ceiling). V.I.C. is applicable to liquids only; all gas flows fall below Viscosity Immunity Ceiling.
3. Meters are not recommended for gas service where pressure is below minimum shown. A flow throtting valve close coupled to meter outlet is recommended for
all gas applications.
S-FL/VA-10A4500_1
CAPACITY TABLE
Bead Guide Meters with USV, SV and NSV Floats
Tube
Size
(Inch)
1/2
3/4
Maxim um Flow
gpm H 2 O
scfm Air
Equivalent
Equivalent
0.267
1.10
0.328
1.35
0.442
1.82
0.480
1.92
0.600
2.47
0.619
2.55
0.670
2.76
0.690
2.85
0.810
3.35
0.830
3.42
0.880
3.62
0.885
3.65
1.10
4.52
1.12
4.60
1.15
4.74
1.19
4.90
1.44
5.93
1.56
6.43
1.66
6.85
2.00
8.24
2.76
11.4
2.90
12.0
3.52
14.5
1.96
8.1
2.49
10.2
2.66
11.0
2.70
11.1
3.37
13.9
3.55
14.6
3.67
15.1
4.80
19.8
4.25
17.5
4.82
19.9
5.63
23.2
6.00
24.7
6.46
26.6
6.80
28.0
7.62
31.4
7.84
32.4
9.00
37.0
9.50
39.2
11.0
45.3
13.2
54.4
14.6
60.0
17.6
72.0
18.6
76.5
24.0
99.0
30.0
123.8
32.0
132.0
36.1
149.0
48.0(5)
60.0(5)
68.0(5)
90(5)
-
Tube Number
Float Num ber
(316 sst)
Total P
(See Note 1)
V.I.C.
(See Note 2)
psia Critical
(See Note 3)
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-27-G-10
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-35-G-10
FP-1/2-17-G-10
FP-1/2-17-G-10
FP-1/2-27-G-10
FP-1/2-21-G-10
FP-1/2-21-G-10
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-27-G-10
FP-1/2-35-G-10
FP-1/2-27-G-10
FP-1/2-27-G-10
FP-1/2-35-G-10
FP-1/2-35-G-10
FP-1/2-50-G-9
FP-1/2-50-G-9
FP-1/2-50-G-9
FP-1/1-50-G-9
FP-3/4-21-G-10
FP-3/4-21-G-10
FP-3/4-21-G-10
FP-3/4-27-G-10
FP-3/4-21-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-1-27-G-10
FP-1-27-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1 - 27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
1/2-GUSVT-40A
1/2-GUSVT-40A
1/2-GUSVT-40A
1/2-GSVT-45A
1/2-GSVT-45A
1/2-GUSVT-40A
1/2-GSVT-44A
1/2-GSVT-48A
1/2-GSVT-45A
1/2-GSVT-44A
1/2-GSVT-48A
1/2-GNSVT-48A
1/2-GNSVT-48A
1/2-GSVT-44A
1/2-GSVT-45A
1/2-GSVT-48A
1/2-GNSVT-48A
1/2-GSVT-44A
1/2-GSVT-48A
1/2-GSVT-45A
1/2-GSVT-44A
1/2-GSVT-48A
1/2-GNSVT-48A
3/4-GSVGT-54A
3/4-GNSVGT-54A
3/4-GSVGT-59A
3/4-GSVGT-54A
3/4-GNSVGT-59A
3/4-GNSVGT-54A
3/4-GSVGT-59A
3/4-GNSVGT-59A
1-GSVGT-64A
1-GSVGT-68A
1-GNSVGT-64A
1-GSVGT-64A
1-GNSVGT-68A
1-GSVGT-68A
1-GNSVGT-69A
1-GNSVGT-64A
1-GNSVGT-68A
1-GSVGT-69A
1-GNSVGT-69A
1 - GSVGT-87A
1 - GSVGT-86A
1 - GNSVGT-87A
1 - GNSVGT-86A
2-GSVGT-97A
2-GSVGT-98A
2-GNSVGT-97A
2-GNSVGT-98A
BL-954
BL-953
BL-950
BL-951
1.2
1.4
2.0
3.5
4.6
3.1
6.4
7.3
6.8
7.7
8.0
8.2
9.9
12.3
8.2
13.7
15.8
14.8
17.2
12.0
31.0
35.2
52.0
5.3
6.8
7.0
7.7
11.5
11.5
13.7
20.5
12.9
18.7
20.7
24.6
32.5
37.0
75.0
37.7
62.8
65.3
112.0
9.5
13.5
12.8
15.2
24.0
34.0
32.0
45.0
70.0
95.0
110.0
192.7
2.9
2.9
2.9
5.1
5.1
2.9
7.1
7.6
5.1
7.1
7.6
1.1
1.1
7.1
5.1
7.6
1.1
7.1
7.6
5.1
7.1
7.6
1.1
10.4
1.6
14.1
10.4
2.1
1.6
14.0
2.1
14.8
16.9
2.2
14.8
2.5
16.9
1.5
2.2
2.5
8.5
1.5
27.6
31.0
4.20
4.80
26.5
18.5
3.0
3.30
2.0
2.0
2.0
1.0
5.5
3.5
2.7
17.9
11.5
2.0
33.4
39.0
8.4
33.8
24.6
19.8
20.0
16.2
8.5
18.6
16.5
16.5
18.8
4.0
7.7
8.9
8.8
13.9
13.9
28.7
9.6
25.3
9.6
19.8
19.8
11.5
15.6
11.3
6.8
15.6
8.9
22.2
6.8
8.9
13.4
13.4
15.4
22.0
15.4
22.0
16.4
21.2
16.4
21.2
-
Note: 1. Pressure drop is total pressure loss across the meter at 100% flow rate in inches of water column.
2. Meter is unaffected by viscosity when the value of cps/r using r = operating density in g/cc and cps = viscosity in centipoises)
is less than V.I.C. (viscosity immunity ceiling). V.I.C. is applicable to liquids only; all gas flows fall below Viscosity Immunity
Ceiling.
3. Meters are not recommended for gas service where pressure is below minimum shown. For such applications use low pressure
drop capacity table. A flow throtting valve close coupled to meter outlet is recommended for all gas applications.
4. Unless other shown, Range is equal to or greater than 12.5:1
5. Short Range Floats; BL-954 is 8:1; BL-953 is 3.5:1; BL-950 & Bl-951 are 3:1.
S-FL/VA-10A4500_1
CAPACITY TABLE
Tube
Size
(Inch)
1/2
3/4
Maximum Flow
gpm Liquid scfm Air
sp. gr. 1.0
@ STP
0.670
2.76
0.690
2.85
0.830
3.42
0.880
3.62
0.885
3.65
1.03
4.24
1.10
4.52
1.12
4.60
1.19
4.90
1.44
5.93
1.56
6.43
1.66
6.85
1.84
7.60
2.00
8.24
2.43
10.0
2.76
11.4
2.90
12.0
3.52
14.5
4.00
16.0
1.96
8.1
2.49
10.2
2.70
11.1
3.15
13.0
3.55
14.6
3.85
15.8
4.35
18.0
5.05
20.8
5.70
23.6
4.25
17.5
4.82
19.8
5.63
23.2
6.00
24.7
6.75
27.9
7.84
32.4
8.46
35.1
9.0
36.9
9.9
40.6
10.8
44.5
11.1
45.7
13.4
55.0
15.4
63.5
16.0
66.0
17.6
72.0
20.4
84.0
21.2
87.0
23.9
99.0
27.9
115.2
31.5
129.8
36.9
152.1
38.2
156.6
Tube Number
Float Number
(316 sst)
Total P
(See Note 1)
V.I.C.
(See Note 2)
psia Critical
(See Note 3)
FP-1/2-17-G-10
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-21-G-10
FP-1/2-17-G-10
FP-1/2-21-G-10
FP-1/2-21-G-10
FP-1/2-27-G-10
FP-1/2-27-G-10
FP-1/2-27-G-10
FP-1/2-35-G-10
FP-1/2-35-G-10
FP-1/2-27-G-10
FP-1/2-35-G-10
FP-1/2-35-G-10
FP-1/2-50-G-9
FP-1/2-50-G-9
FP-1/2-50-G-9
FP-1/2-50-G-9
FP-3/4-21-G-10
FP-3/4-21-G-10
FP-3/4-27-G-10
FP-3/4-21-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-3/4-27-G-10
FP-1-27-G-10
FP-1-27-G-10
FP-1-27-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1-35-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-1 -27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
FP-2-27-G-10
1/2-GSVTA-44
1/2-GSVTA-48
1/2-GSVTA-44
1/2-GSVTA-48
1/2-GNSVTA-48
1/2-GNSVTA-44
1/2-GNSVTA-48
1/2-GSVTA-44
1/2-GSVTA-48
1/2-GNSVTA-48
1/2-GSVTA-44
1/2-GSVTA-48
1/2-GNSVTA-43
1/2-GNSVTA-48
1/2-GNSVTA-43
1/2-GSVTA-44
1/2-GSVTA-48
1/2-GNSVTA-48
-GNSVTA-43
3/4-GSVTA-54
3/4-GNSVTA-54
3/4-GSVTA-54
3/4-GSVTA-53
3/4-GNSVTA-54
3/4-GSVTA-56
3/4-GSVTA-53
3/4-GNSVTA-56
3/4-GNSVTA-53
1-GSVTA-64
1-GSVTA-65
1-GNSVTA-64
1-GSVTA-64
1-GSVTA-65
1-GNSVTA-64
1-GSVTA-63
1-GNSVTA-65
1-GSVTA-66
1-GNSVTA-66
1-GNSVTA-63
1 - GSVTA-84
1 - GSVTA-85
1 - GSVTA-83
1 - GNSVTA-84
1 - GNSVTA-85
1 - GNSVTA-83
2-GSVTA-94
2-GSVTA-93
2-GNSVTA-94
2-GNSVTA-96
2-GNSVTA-93
6.4
7.3
7.7
8.0
8.2
8.9
9.9
12.3
13.7
15.8
14.8
17.2
18.5
19.0
30.0
31.0
35.2
52.0
72.0
5.3
6.8
7.7
11.0
11.5
12.0
13.0
14.0
16.0
12.9
15.0
20.7
24.6
27.0
37.7
45.0
62.8
75.0
112
120
10.0
14.0
16.0
15.0
18.0
20.0
24.0
30.0
32.0
47.0
50.0
7.1
7.6
7.1
7.6
1.1
1.1
1.1
7.1
7.6
1.1
7.1
7.6
1.3
1.1
1.3
7.0
7.6
1.1
1.3
10.4
1.6
10.4
16.6
1.6
14.9
16.8
2.2
2.5
14.8
16.9
2.2
14.8
16.9
2.2
20.8
2.5
8.5
1.5
2.9
27.6
32.0
33.0
4.2
5.0
4.9
40.5
49.0
6.1
7.6
7.3
33.4
39.0
33.8
24.6
19.8
33.4
20.0
16.2
18.6
16.5
16.5
18.8
27.5
8.8
22.7
7.7
8.9
8.8
12.3
13.9
13.9
9.6
36.0
9.6
19.8
25.0
19.8
25.0
11.5
14.8
11.3
6.8
8.9
6.8
13.9
8.9
13.4
14.5
13.1
15.4
20.3
22.0
15.4
20.3
22.0
16.4
24.0
17.4
21.2
24.0
Range
(See Note
4)
11.1:1
11.1:1
7.1:1
7.1:1
10.0:1
4.8:1
7.7:1
5.3:1
7.7:1
5.3:1
8.3:1
10:1
4.3:1
9.1:1
9.1:1
4.3:1
6.2:1
5.3:1
6.2:1
5.3:1
6.7:1
3.6:1
6.7:1
7.1:1
3.6:1
Note: 1. Pressure drop is total pressure loss across the meter at 100% flow rate in inches of water column.
2. Meter is unaffected by viscosity when the value of cps/r using r = operating density in g/cc and cps = viscosity in centipoises)
is less than V.I.C. (viscosity immunity ceiling). V.I.C. is applicable to liquids only; all gas flows fall below Viscosity Immunity
Ceiling.
3. Meters are not recommended for gas service where pressure is below minimum shown. For such applications use low pressure
drop capacity table. A flow throtting valve close coupled to meter outlet is recommended for all gas applications.
4. Unless other shown, Range is equal to or greater than 12.5:1
5. Short Range Floats; BL-954 is 8:1; BL-953 is 3.5:1; BL-950 & Bl-951 are 3:1.
S-FL/VA-10A4500_1
Dimension Drawings
Meter
Tube Size
1/2
3/4 to 1
Meter
Tube Size
1-1/2 to 2
Dim.
Inch
mm
Inch
mm
Inch
mm
19-5/16
490
21-3/16
538
26-7/15
671
Dim.
A
1/2
3/4 to 1
Inch
18-9/16
mm
471
1-1/2 to 2
Inch
20
mm
508
Inch
24-5/16
mm
618
16-1/2
419
17-1/2
445
20-1/2
521
20-5/8
524
22-1/8
562
27-11/16
703
1-13/32
37
1-27/32
47
2-31/32
75
2-21/32
68
3-5/32
80
5-7/32
133
3-1/2
89
103
127
1-5/8
41
2-3/32
53
3-17/32
90
3-3/8
86
4-3/8
111
5-11/16
144
3-3/8
86
4-3/8
111
5-11/16
144
2-5/8
67
3-27/64
87
4-7/8
124
2-5/8
67
3-27/64
87
4-7/8
124
8-1/4
210
8-3/4
222
10-1/4
260
7-21/32
194
7-29/32
201
8-5/8
219
1-1/2
38
1-59/64
49
2-5/8
67
1-1/2
38
1-59/64
49
2-5/8
67
1-1/4
32
1-1/2
38
2-1/2
64
1-1/4
32
1-1/2
38
2-1/2
64
1/2
13
3/4
19
1-1/2
38
1/2
13
3/4
19
1-1/2
38
3/4
19
1-1/8
29
1-7/8
48
3/4
19
1-1/8
29
1-7/8
48
1/2
13
25
1-1/2
38
1/2
13
25
1-1/2
38
S-FL/VA-10A4500_1
FRONT PANEL MOUNTING
FRONT PANEL MOUNTING
10A4500 / 4500 SERVICES
Note: Front Panel Mounting Not Available with Alarms
REAR PANEL MOUNTING
C onn. Size
Scale
Length
D im .
A
B
C
D
E
F
G
H
J
K
1/2
3/4 & 1
1-1/2
10
10
10
Inch
16-3/16
4-9/16
2-5/8
1-1/2
5
13-5/8
2-11/16
3-7/16
14-7/16
1-1/4
S-FL/VA-10A4500_1
mm
411
116
67
38
127
346
68
87
367
32
Inch
16-3/16
5-1/4
3-7/16
1-15/16
5-15/16
13-7/8
3-3/8
4-1/8
14-13/16
1-11/16
mm
411
133
87
49
151
352
86
105
376
43
Inch
17-3/4
6-1/8
4-7/8
2-5/8
7-5/8
15-5/16
4-1/4
5
16-1/4
2-3/8
mm
451
156
124
67
200
389
108
127
413
60
MODEL NUMBER DESIGNATION
Variable Area Flowmeters
10A4
__ __
__ __ __ __ __ __
__ __
Pressure Seals
O-ring Pressure Seals ................................................................................. 55
Packing Gland Type Pressure Seals .......................................................... 65
Connection Designation
Horizontal Threaded ............................................................................................
Horizontal Flanged ..............................................................................................
Vertical Threaded ................................................................................................
Vertical Flanged ..................................................................................................
5
6
7
8
Scales
Percent on Tube .......................................................................................................... X
Direct Reading on Tube .............................................................................................. Y
Direct Reading Metal Scale and Percent on Tube ...................................................... E
Percent on Metal Scale ............................................................................................... P
Direct Reading Metal Scale ......................................................................................... S
Dual Direct Reading Metal Scales ............................................................................. D
Panel Mounting
Line Mounted ...................................................................................................................... X
Front Panel Mounted .......................................................................................................... Y
Rear (Flush) Panel Mounted .............................................................................................. Z
Design Level ................................................................................................................................ B
Sizes (inches)
Conn. Size
1/2
3/4 (NPT)
3/4 (NPT)
1 (Flgd)
1 (Flgd)
1-1/2
1-1/2
Tube Size
1/2 ............................................................................................................................. H
3/4 ............................................................................................................................. J
1 ................................................................................................................................ K
3/4 ............................................................................................................................. L
1 ................................................................................................................................ M
1-1/2 ......................................................................................................................... N
2 ................................................................................................................................ P
Fitting Material
Brass/Bronze ........................................................................................................................................... B
316 Stainless Steel ................................................................................................................................. C
Seal Material
Packaging Gland Design - Neoprene ............................................................................................................. E
Packaging Gland Design - Teflon .................................................................................................................. D
O-ring Design - Buna-N ................................................................................................................................... F
O-ring Design - Viton ...................................................................................................................................... H
O-ring Design EPR .......................................................................................................................................... J
Connection Type
NPT ........................................................................................................................................................................ B
Flat Face Flange Class 125 (Brass/Bronze only) .................................................................................................. C
R.F. Flange Class 150 (316 sst only) .................................................................................................................... D
Alarms
Not Required .................................................................................................................................................................. X
Low Alarm (SPDT) ......................................................................................................................................................... C
High Alarm (SPDT) ......................................................................................................................................................... B
High & Low Alarm (SPDT) .............................................................................................................................................. D
Low Alarm (DPDT) ......................................................................................................................................................... F
High Alarm (DPDT) ........................................................................................................................................................ E
High & Low Alarm (DPDT) ............................................................................................................................................. G
High & High Alarm (SPDT) ............................................................................................................................................. H
Low & Low Alarm (SPDT) .............................................................................................................................................. J
High & High Alarm (DPDT) ............................................................................................................................................. K
Low & Low Alarm (DPDT) .............................................................................................................................................. L
S-FL/VA-10A4500_1
The Companys policy is one of continuous product
improvement and the right is reserved to modify the
information contained herein without notice.
2000 ABB Automation Inc.
ABB Automation Inc.
125 East County Line Road
Warminster, PA 18974 USA
Tel: 215-674-6000
Fax: 215-674-7183
S-FL/VA-10A4500_1
ABB Instrumentation Ltd
Howard Road, St. Neots
Cambs, England, PE19 3EU
Tel: +44 (0)1480-475-321
Fax: +44 (0)1480-217-948
ABB Instrumentation S.p.A
Via Sempione 243
20016 Pero (Milano) Italy
Tel: +39 (02) 33928 1
Fax: +39 (02) 33928 240
10