SSV20051 1709
SSV20051 1709
2. Features
Measurement in high accuracy is possible as rotor rotates at constant speed.
Due to small revolution resistance, it gives large volume measurement with low
pressure loss.
It is less subject to temperature and viscosity, and possible the stable meas-
urement with always high accuracy.
Easy-to-read big indicator.
Easy expansion with variety of pulse generators available for loading.
3. Specifications
Specifications of measuring unit
080 100 150
Nominal size & volume symbol
B0 A0 B0 A0
Measured fluid Chemical solutions, petroleum, water, etc.
Nominal size 80A 100A 150A
Liquid viscosity 0.4 ~ 500 mPa・s
Liquid temperature Normal temperature ~ 80℃ ( 0 ~ 120℃ (High temperature specification))
Liquid pressure 2.0 MPa or under (By flange standards)
Measuring accuracy Within ±0.5% or within ±0.2%(Counter symbol A0 only and liquid temperature 60 °C. or lower)
JIS10K, 20K, ANSI class 150(For the details, see paragraph of “Process connection and
Standard connection
face-to-face dimensions”)
Symbol Body Measuring chamber Rotor Rotor shaft Vane
FF FC200 FC200 AC3A SK4 Special carbon
Material
S7 SCS13 SCS13 SCS13 SCS13 Special carbon
FC200:Cast iron, SCS13:Stainless steel casting, AC3A:Corrosion-resistant aluminum, SK4:Tool steel
Special specifications Article approved for high-pressure gas service: Only material symbol S7 is manufacturable (only size 80A).
Type of signal Either one of (1) voltage no-contact signal (high frequency type), or (2) reed switch contact signal.
Pulse output
Unit
pulse No-contact pulse output See “No-contact pulse output” table.
Output
Output unit
Contact pulse output See “Contact pulse output” table.
DA conversion pulse No-contact pulse output possible.
(Note) No simultaneous output of unit pulse and DA conversion pulse can be made.
Analogue output Direct output impossible. (DA converter required outside.)
SS
The following external power source is required for outputting voltage no-contact signals: High fre-
Power source
quency type pulse generator: 6~26.4VDC
Ambient temperature 0~60℃
Flameproof enclosure type
Explosion-protection ExdⅡBT4
Either one of high frequency pulse generator or reed switch pulse generator.
0V
Max. generated pulse : 140P/sec
Power source : 6 – 26.4VDC
Power consumption : 23 mA or less (+V = 24VDC)
17 mA or less (+V = 12VDC)
4. Flow range(m3/h)
Accuracy: ± 0.5%
Nominal size
Working Water (Normal
& volume 0.4mPa・s~ 2mPa・s~ 5mPa・s~ 10mPa・s~ 50~500mPa・s
condition temperature)
symbol
080B0 Continuous 10~60 12~60 10~80 8~80 5~80 3~60
100A0 Intermittent 10~80 12~80 10~100 8~100 5~100 3~80
100B0 Continuous 20~120 24~120 20~160 16~160 10~160 6~120
150A0 Intermittent 20~160 24~160 20~200 16~200 10~200 6~150
Accuracy: ± 0.2% (Counter symbol A0 only and liquid temperature 60 °C. or lower)
Nominal size
Working Water (Normal tem-
& volume 0.4mPa・s~ 2mPa・s~ 5mPa・s~ 10mPa・s~ 50~500mPa・s
symbol condition perature)
5. Pressure loss
Pressure loss
Flow rate 100%
0.08 Nominal size &
300 mPa・s Flow rate 100%
0.07 volume symbol
0.06 080B0, 100A0 100 m3/h
0.05 100 mPa・s 100B0, 150A0 200 m3/h
MPa
0.04 50 mPa・s
0.03 10 mPa・s
0.02 5 mPa・s
0.01 1 mPa・s
0.00
0 20 40 60 80 100
Flow rate %
Note) Process connection for which no numerical value is indicated on the table cannot be manufactured.
SS
7. Piping method
Install a strainer on the inlet side of the flow meter without fail. To avoid outflow to the downstream side due to damage of internal
component parts, install a strainer also on the outlet side of the flow meter. (Note) The standard mesh of the strainer element is 60
meshes.
Install a bypass piping. In designing this bypass piping, take account of protection of the inner elements of the flow meter against
the
influences of flushing in the early period of operation or discharge of air in the piping as well as ease of maintenance and inspection
work.
Secure a space necessary for inspection, disassembling, etc. of the flow meter in the piping arrangement. Especially, secure a
space for enabling disassembling of the measuring chamber of the flow meter.
Horizontal piping
(Vertical installation) Vertical piping
●Direct-reading type
●Explosion-protection type
SS 0
Volume symbol
Flange standard
Nominal size symbol
Material
Flange shape
Slide vane flow meter
Counter symbol
Supplementary specifications
Type of generator and pulse unit
●: Standard; ○: Manufacturable; ×: Non-manufacturable
Type Specification code Specifications 080B0 100A0 100B0 150A0
SS Slide vane flow meter ● ● ● ●
A0 Pointer and direct-reading type ● ● ● ●
11.Strainer
To avoid a flow meter trouble caused by foreign matter in a liquid coming into the flow meter, it is necessary to install a strainer shortly
before or as near as before the upstream side of the flow meter.