CPac (Mr. Slim) R410a Catalog
CPac (Mr. Slim) R410a Catalog
Inverter Series
Ceilingcassette
(PLY SERIES)
24,000 BTU/h
30,000 BTU/h
36,000 BTU/h
42,000 BTU/h
48,000 BTU/h
Remote Controller
01-02
Contents
P. 07-09
PLY-P18BA
PLY-P24BA
PLY-P30BA
PLY-P36BA
PLY-P42BA
PLY-P48BA
optional
Ceilingsuspended
(PCY SERIES)
optional
PCY-P18KA
PCY-P24KA
PCY-P30KA
PCY-P36KA
PCY-P42KA
P. 10
PCY-P48KA
optional
Ceilingconcealed
(PEY SERIES)
optional
PEY-P18JA
PEY-P24JA
PEY-P30JA
PEY-P36JA
PEY-P42JA
PEY-P48JA
optional
Outdoor Unit
SUY-KA18VA
SUY-KA24VA
SUY-KA30VA
SUY-KA36VA
PUY-P42V/YKA
PUY-P48V/YKA
For twin multi-operation (only PUY-P48V/YKA),
please refer to page 12.
P. 11
03-04
Inverter Series
R 410A refrigerant
As scientific evidence points to man-made chemicals for the damage caused to the ozone layer, we only
use chlorine-free refrigerants that are safe and rated zero ODP (Ozone Depletion Potential). Accordingly, our
systems require less energy to run and have a significantly lower indirect global warming potential. In short,
we produce the most efficient equipment possible, while helping to protect the environment.
The Montreal Protocol calls for the complete abolishment of HCFC (such as R22) refrigerant production by the year 2020.
Mitsubishi Electric is committed to shifting over to HFC models from HCFC models.
Montreal Protocol
Comfort
Efficiency
Durability
C
Freon
CFC-11 CI
Mitsubishi Electric
has introduced HFC
refrigerants to meet
the target.
35%
2004
2010
2015
O2
CI
O2
2020
Chlorine monoxide
CIO
Oxygen
Complete
phase-out
10%
1995
Oxygen
Chlorine
F
O O
65%
O O
CI
C
CI
in 1989 of 100%.
Ozone
O O3
CI
F
CI
CI
CI
(CCI3F)
Oxygen
O
Ozone molecules react with chlorine atoms and are broken down
into oxygen atoms and chlorine monoxide.
Oxygen atoms react with chlorine monoxide to form oxygen
molecules and chlorine atoms.
05-06
Inverter Series
INVERTER TECHNOLOGIES
OTHER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance, including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost Thats the Mitsubishi Electric promise.
PAM is a technology that controls the current waveform so that it resembles the supply voltage wave, thereby reducing loss and realising
more efficient use of electricity. Using PAM control, 98% of the input
power supply is used effectively.
With PAM control
ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter-equipped air conditioners. We have combined advanced inverter technologies
with cutting- edge electronic and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling
performance efficiency. As a result, better performance and lower energy consumption are achieved.
Current
Time
PAM adjusts the form of the current wave so that it becomes close to that of the
supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Neodymium
magnets
DC compressor
motor ( rotor )
Electricity is wasted
Magnetic torque
Reluctance torque
ON
Compressor operation
Change in room
temperature
OFF
ON
Minimum power
consumption
Preset
temperature
Preset
temperature
Change in room
temperature
Full power
OFF
DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor.
Time
Compressor operation
Time
Point 2
Grooved piping
Pipe image
Cross-sectional view
Mitsubishi Electrics A-control system adopts a single-line method for power and control that combines the power and control lines between the indoor and outdoor units into a single line. Power is obtained from a line on the outdoor unit. Additionally, a single triplex line is sufficient for wiring between indoor units for the Twin-multi system.
Outdoor unit system control comparison
Switching from AK-control to A-control system results in tremendous reduction in wiring work!
AK-control (previous)
Grooved Piping
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the preset room temperature.
This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners
equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room
temperature. This ensures energy-efficient operation and a more comfortable room.
Point 1
Conventional
inverter
Limited power
ON
PAM
Below is a simple comparison of air conditioner operation control with and without an inverter.
TRUE COMFORT
Power increased
A-control (new)
Indoor unit
power
Indoor unit
Outdoor unit
Power line
Control line
Indoor unit
Outdoor unit
07-08
Inverter Series
4-way
Ceilingcassette
(PLY SERIES)
Wide Airflow
Wide-angle outlets distribute
airflow to all corners of the room,
ensuring the room is sufficiently
cooled/heated. Horizontal airflow
and a fan speed reduced by 20%
compared to conventional models
also contribute to increased
comfort for occupants.
Conventional model
Ceiling cassette models boast a slim body height for smooth and aesthetic installation, even in narrow spaces.
PLY-P18/24BA
PLY-P30/36/42/48BA
PLY-P BA
An improved airflow path and powerful highcapacity flow fan contribute to the realisation of
quieter operation.
PLY-P18/24/30/36/42/48BA
optional
PLY-P18/24BA
PLY-P30/36/42/48BA
4-way
2.5
2.7
3.5
2.7
3.2
4.5
3-way
2.7
3.0
3.5
3.0
3.6
4.5
If required to use Low Ceiling mode under high humidity conditions, please consult with your
Mitsubishi Electric dealership since there is some risk of condensation.
90
rotation
High
5sec
measurement
Automatic
elevation to
4.0m
90
rotation
5sec
measurement
90
rotation
5sec
measurement
5sec
measurement
1.2m
1.6m
Example
2.0m
Fixed condition
Fixed condition
32C
23C
Medium 1
2.4m
Medium 2
Other Features
Low
Quiet Operation
Elevating (up-down)
controller
(comes with the automatic elevation panel)
2.8m
Sensible temperature: 26.5C
3.2m
Fixed condition
Fixed condition
Floor temperature
Floor temperature
Sensible temperature
Sensible temperature
3.6m
28 C
26.5 C
28C
26.5C
Inlet temperature
4.0m
30 minutes
Inlet temperature
30 minutes
14C
Inverter Series
Vane Control
Fresh-air Intake
For
Shopping
Malls
4.5m*
For Retail
Outlets
(e.g. grocery
stores)
(PCY SERIES)
Fixed
Fixed
Fixed
Fixed
PC-GAKD
PCY-P K A
Refrigerated
showcase not
affected by air
conditioning
4-way outlets
Ceilingsuspended
09-10
PCY-P18/24/30/36/42/48KA
Strong
optional
Gentle
optional
Start of cooling
After room
temperature is stabilised
Fresh-air Intake
In office environments, annoying drafts can be bothersome, leading to discomfort and reduced productivity. Precise vane control
helps to eliminate this problem.
4-way outlets
Fixed
Top or bottom
airflow setting via
remote controller
Fixed
Top or bottom
airflow setting via
remote controller
Separate vane
adjustments allow
different settings
per vane for a more
flexible airflow
Female employee who
dislikes an excessively
cool environment.
PCY-P30/36/42/48/KA
PCY-P18/24KA
0
Flockless Vanes
With the adoption of flockless vanes, dirt and other impurities
can be cleaned off easily using a mild household detergent.
Features at a glance
Fixed
50
0
50
100
150
200
250
300
Fixed
For
Offices
Comfort
i- see Sensor
Auto fan speed
Wide vane
Smudge/ draft- free
High- ceiling application
Computerized dehumidifier
Quiet operation
Bacteria- and mold- resistant filter
Others
System control
Twin- multi operation
Auto vane shutter
Auto restart
Fresh- air intake
Outdoor unit max.
operating temp. of 46C
Features at a glance
Installation & Maintenance
Chargeless system
New direct suspension system
Drain water lifting (600mm)*1
Flexible piping
Long-life filter (2500hr)*2
High-efficiency filter*1
Self-diagnostic function
Comfort
Auto swing
Computerized dehumidifier
Quiet operation
*1 Optional
*2 May vary according to operating conditions.
Others
System control
Twin- multi operation
Auto restart
Auto vane shutter
Outdoor unit max. operating
temp. of 46C
CONTROL
TECHNOLOGIES
Ceilingconcealed
11-12
Twin-multi Operation
Indoor unit
Indoor unit
PUY-P48V/YKA
Multi-distribution pipe
(PEY SERIES)
Inverter Series
24 + 24
MSDD-50TR-E
Note
Multi-distribution pipe
Height reduced
250mm
Air Inlet
Units with bottom inlets make more noise than those with rear
inlets. It is recommended that the rear inlet be selected when
installing a unit in a room that should be quiet, such as a bedroom.
(1) Rear inlet
Outdoor unit
Air inlet
Air inlet
PEY-P18/24/30/36/42/48JA
Air outlet
optional
optional
Air outlet
Mr. SLIM
Convenient Remote Controller
18
PEY-P . JA
24
30
36
42
48
Stylish wireless remote controller with all the latest programming features
FAN SPEED SELECT button
Used to change fan speed.
Features at a glance
Installation & Maintenance
Chargeless system
Smooth installation
Self-diagnostic function
Comfort
Computerized dehumidifier
Quiet operation
Others
System control
Twin-multi operation
Auto restart
Outdoor unit max.
operating temp. of 46C
CONTROL
TECHNOLOGIES
User-friendly Deluxe Remote Controller with Excellent
Operability and Visibility
PAR-31MAA (Optional)
Full-dot LCD
[Spanish]
[Italian]
[German]
[Russian]
[French]
Operation
Lock
In addition to operation start/stop, the operation mode, temperature setting and airflow direction can be locked. Unwanted adjustment of temperature settings is prevented and an appropriate temperature is constantly maintained, leading to energy
savings. This feature is also useful in preventing erroneous operation or tampering.
Recommended for
Weekly
Timer
School
Public hall
The Weekly Timer enables the setting of operation start and stop times and adjusting
the temperature as standard features. Up to 8 patterns per day can be set, providing
operation that matches the varying conditions of each period, such as the number of
customers in the store.*Weekly Timer cannot be used when On/Off Timer is in use.
Busy
hours
30(C)
30(C)
Restaurant
When using Auto-off Timer, even if one forgets to turn off the unit, operation stops
automatically after the preset time elapses, thereby preventing wasteful operation. Auto-off Timer can be set in 10-minute units, in a range between 30 minutes
and 4 hours. Eliminates all anxiety about forgetting to turn off the unit.
Changing room
30(C)
[French]
[Russian]
[Chinese]
[Japanese]
25
Opening
time
24
4
5
Dinner time
10
12
14
16
18
Automatic
Grille Lowering
(4-way ceiling cassette)
Recommended for
20
22
Office
Restaurant
Set the time for the air conditioner to turn off automatically. The timer can be set
in the range from 30 minutes up to 4 hours in 30-minute intervals.
The Simple Timer starts/stops in units of 1 hour in a 72-hour period is set at
the time of shipment from the factory. It can be changed to the Auto-off Timer
function using the remote controller.
Recommended for
8-pattern setting
22
0
Closing time
Lunch time
23
30(C)
Meeting room
Changing room
24 (Time)
Operation
Lock
Units can be set so that the operation mode cannot be changed. When Operation Lock is activated, new temperature setting commands are not accepted,
thereby ensuring that the unit runs in the specified (locked in) temperature range.
This promotes energy savings and prevents erroneous/ mischievous operation.
Only the administrator can change settings when using the Operation Lock mode.
Recommended for
Office
Hospital
School
Public hall
Introduced in response to
market demand
Auto-off
Timer
Meeting room
Preparation
house calculations
Recommended for
Cooling/Dry
Auto-off
Timer
[German]
Set the upper and lower limits for the temperature range during operation.
Excessive cooling is prevented, leading to increased energy savings.
19(C)
26
Office
[Italian]
Weekly
Timer
25(C)
This function monitors the room temperature and automatically activates the
cooling mode when the temperature rises above the preset maximum temperature setting.
25(C)
Office
Hospital
19(C)
Temperature
Range
Restriction
After adjusting the initial temperature on a hot day, it is easy to forget to return the
temperature setting to its original value. The Auto-return function automatically
resets the temperature back to the original setting after a specified period of time,
thereby preventing overcooling. The Auto-return activation time can be set in 10minute units, in a range between 30 and 120 minutes.
Recommended for
[Spanish]
[English]
Energy-efficient Control
Cooling/Dry
[Portuguese] [Swedish]
Energy-efficient Control
Temperature
Range
Restriction
MultiIanguage
Dot LCD
Multi-language Display
PAR-21MAA
MultiIanguage
Easy-to-Read/Easy-to-Use
Multi-language Display
PAR-31MAA
Display Example [Operation Mode]
Night
Setback
PAR-21MAA
Auto-return
13-14
Inverter Series
Busy
hours
Off-peak
hours
25
Closing time
Opening time
24
Lunch time
23
7-pattern setting
22
0
Dinner time
10
12
14
16
18
20
22
24 (Time)
SYSTEM CONTROL
Inverter Series
15-16
Versatile system control can be realised using optional parts, relay circuits, control panels, etc.
System Examples
Indoor Unit
Outdoor Unit
Details
Indoor unit
2-remote Controller
Control
PAR-SL97A-E
PAR-31MAA Control
PAR-21MAA Control
PAR-31MAA
PAR-21MAA control
PAR-31MAA
PAR-21MAA
PAR-31MAA
PAR-21MAA
* When using wired and
wireless remote controllers
(Example of 1 : 1 system)
Outdoor unit
B
Details
Standard equipment (for indoor units compatible with wired remote controllers)
Indoor unit
Outdoor unit
Outdoor unit
Remote
control
panel
Relay box
(to be purchased locally)
Relay box
(to be purchased locally)
Adapter
for remote
On/Off
Adapter
for remote
On/Off
Wired remote
controller
(Example of 1 : 1 system x 2)
Indoor unit
Indoor unit
PAR-31MAA
PAR-21MAA
Operation Control by
Pulse Signal
PAR-31MAA
PAR-21MAA
Outdoor unit
Outdoor
unit
Outdoor
unit
Indoor unit
Indoor unit
Remote
control
panel
Wired remote
controller
M-NET Connections
PAR-31MAA
PAR-21MAA
MAC-333IF-E
Relay box
(to be purchased locally)
Connector
cable for
remote
display
Remote
control
panel
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Remote Display of
Operating Status
Remote
display
panel
Remote
display
panel
PAR-SL97A-E
PAR-31MAA /PAC-YT52CRA
City Multi
indoor unit
PAR-31MAA
PAR-21MAA
(Example of 1 : 1 system x 2)
Outdoor unit
One remote controller can simultaneously control multiple air conditioners with the same settings.
One remote controller can control up to 16 refrigerant systems.
Up to two remote controllers can be connected.
MAC-333IF-E (interface)
PAR-31MAA (wired remote controller)
PAR-21MAA (wired remote controller)
PAR-SL97A-E
Connector
cable for
remote
display
(Example of 1 : 1 system x 2)
Details
Remote
control
panel
Relay box
(to be purchased locally)
Indoor unit
MAC-333IF-E
Operation Control by
Level Signal
MELANS
system controller
(AG-150A etc)
PAC-SC51KUA
power supply unit
PAC-SC51KUA
power supply kit
Indoor unit
PAR-31MAA
PAR-21MAA
Outdoor unit
MELANS
system controller
(AG-150A etc)
(Example of 1 : 1 system)
Indoor unit
MAC-333IF-E (interface)
MELANS system controller
PAC-SC51KUA (power supply unit)
PAR-31MAA
PAR-21MAA
Outdoor unit
M-NET adapter
PAC-SF83MA-E
Details
Operation/emergency signal
can be received at a remote
location (when channeled
through the PAC-SF40RM-E
no-voltage signal, when
channeled through the
PAC-SA88HA-E DC 12V
signal).
Timer Operation
PAR-31MAA
(Example of 1 : 1 system)
Weekly Timer:
On/Off and up to 8 pattern
temperatures can be set for each
calendar day (initial setting).
On/Off Timer:
On/Off can be set once each
within 72 hr in intervals of 5min.
Auto-off Timer:
Operation will stop after a
preset time elapses. Set time
can be changed from 30min to
4hr in 10min intervals.
*Simple Timer and Auto-off Timer cannot
be used at the same time.
Standard functions of
PAR-31MAA
SPECIFICATIONS
4-way Ceiling-cassette (50Hz/60Hz)
Models
Cooling capacity
Cooling capacity (rated)
Total input
EER
Ceiling-concealed (50Hz/60Hz)
PLY-P18BA
PLY-P24BA
PLY-P30BA
PLY-P36BA
kW
5.3 (2.8-5.4)
7.1 (3.6-8.9)
8.8 (4.1-9.7)
10.6 (4.1-10.7)
12.3 (6.2-14.1)
13.2 (6.6-15.0)
BTU/h
18,000
24,000
30,000
36,000
42,000
45,000
kW
1.47
2.02
2.36
3.13
3.68
4.31
Total input
W/W
3.61
3.51
3.73
3.39
3.34
3.06
EER
PLY-P18BA
PLY-P24BA
PLY-P30BA
PLY-P36BA
Model name
50Hz
Power supply
Indoor
unit
60Hz
CMM
CFM
PLY-P42BA
PLY-P48BA
PLY-P42BA
PLY-P48BA
12-13-14-16
14-16-18-20
Cooling capacity
Cooling capacity (rated)
PLY-P48BA
24-26-29-32
28-30-32-34
37-39-41-44
mm
840 (950)
mm
840 (950)
mm
kg
Model name
Power supply
Indoor
unit
33-35-38-41
32
24 (6)
SUY-KA18VA
SUY-KA24VA
SUY-KA30VA
50Hz
1ph 220-240V
60Hz
1ph 220V
External finish
Dimensions
PUY-P42VKA
PUY-P42YKA
PUY-P48VKA
PUY-P48YKA
3ph 380-415V
1ph 220-240V
3ph 380-415V
3ph 380V
1ph 220V
3ph 380V
dB (A)
51
mm
800
mm
285
330
330
mm
550
880
1338
Weight
kg
33
12
51 (1800)
56
58
55
51
56
42,000
46,000
3.33
3.84
4.41
W/W
3.38
3.51
3.52
3.18
3.20
3.06
PEY-P18JA
PEY-P24JA
PEY-P30JA
PEY-P36JA
94
Outdoor
unit
96
94
15
96
Dimensions
PEY-P42JA
PEY-P42JA
PEY-P42JA
PEY-P48JA
PEY-P42JA
PEY-P48JA
12-14.5-17
17.5-21-25
24-29-34
29.5-35.5-42
CFM
425-510-600
620-740-885
850-1025-1200
1040-1225-1485
35-50-70-100-125
Remote control and Built-in
30-35-39
30-34-39
33-38-42
36-40-44
mm
mm
mm
mm
kg
32
900
1100
1400
732
250
27
29
38
SUY-KA18VA
SUY-KA24VA
SUY-KA30VA
50Hz
1ph 220-240V
60Hz
1ph 220V
39
SUY-KA36VA
PUY-P42VKA
PUY-P42YKA
PUY-P48VKA
PUY-P48YKA
3ph 380-415V
1ph 220-240V
3ph 380-415V
3ph 380V
1ph 220V
3ph 380V
34 (1200)
dB (A)
51
mm
800
mm
285
330
330
mm
550
880
1338
Weight
kg
33
30
12
46 (1625)
54
51 (1800)
56
130 (4595)
58
55
56
840
47
50
15
1050
51
94
96
94
30
20
30
50
20
30
50
mm
Liquid: 6.35
Gas: 12.5
mm
Liquid: 6.35
Gas: 12.5
30
Models
Cooling capacity
Cooling capacity (rated)
Total input
EER
PCY-P24KA
PCY-P30KA
PCY-P36KA
5.3 (2.8-5.4)
7.1 (3.6-8.9)
8.8 (4.1-9.7)
10.6 (4.1-10.7)
12.3 (6.2-14.1)
13.5 (6.6-15.0)
BTU/h
18,000
24,000
30,000
36,000
42,000
46,000
kW
1.51
2.1
2.6
3.13
3.68
4.41
W/W
3.51
3.38
3.38
3.39
3.34
PCY-P18KA
PCY-P24KA
PCY-P30KA
PCY-P36KA
Model name
50Hz
Power supply
PCY-P42KA
PCY-P42KA
PCY-P48KA
3.06
PCY-P42KA
60Hz
1ph 220V
Munsell 6.4Y 8.9/0.4
CMM
Airflow (low-mid2-mid1-high)
CFM
16-17-18-20
16-18-20-22
24-26-28-30
27-29-32-34
955-1025-1130-1200
Pa
0 (direct blow)
dB (A)
mm
mm
mm
mm
Weight
34-36-38-40
39-41-43-45
42-44-46-48
1280
1600
680
230
32
SUY-KA18VA
Power supply
34-36-40-42
26
kg
Model name
37
SUY-KA24VA
SUY-KA30VA
50Hz
1ph 220-240V
60Hz
1ph 220V
External finish
40
SUY-KA36VA
PUY-P42VKA
PUY-P42YKA
PUY-P48VKA
PUY-P48YKA
3ph 380-415V
1ph 220-240V
3ph 380-415V
3ph 380V
1ph 220V
3ph 380V
Airflow
CMM (CFM)
34 (1200)
dB (A)
51
mm
800
840
mm
285
330
330
mm
550
880
1338
Weight
kg
33
12
Noise level
Dimensions
PCY-P48KA
PCY-P48KA
1ph 220-240V
External finish
Dimensions
PCY-P42KA
PCY-P48KA
PCY-P18KA
kW
46 (1625)
54
51 (1800)
56
47
50
15
130 (4595)
58
55
56
1050
51
94
96
94
30
20
30
50
mm
Liquid: 6.35
Gas: 12.5
30
96
PEY-P48JA
1ph 220V
PEY-P48JA
1ph 220-240V
CMM
Noise level
Ceiling-suspended (50Hz/60Hz)
Outdoor
unit
36,000
2.5
Airflow
1050
50
30,000
2.02
dB (A)
Power supply
130 (4595)
840
47
24,000
1.57
34 (1200)
54
18,000
kW
External finish
CMM (CFM)
Noise level
46 (1625)
BTU/h
Model name
Airflow
13.5 (6.6-15.0)
Pa
Weight
12.3 (6.2-14.1)
26 (6)
SUY-KA36VA
10.6 (4.1-10.7)
Galvanized sheet
298 (35)
22 (6)
PEY-P36JA
8.8 (4.1-9.7)
60Hz
258 (35)
19 (6)
PEY-P30JA
7.1 (3.6-8.9)
50Hz
Airflow (low-mid-high)
0 (direct blow)
28-29-30-32
PEY-P24JA
5.3 (2.8-5.4)
Model name
850-920-1025-1130
Remote control and Built-in
dB (A)
PEY-P18JA
kW
External finish
20-22-25-28
mm
Weight (panel)
Indoor
unit
Models
Power supply
Pa
Dimensions
PLY-P48BA
1ph 220V
Outdoor
unit
PLY-P42BA
Dimensions (panel)
PLY-P42BA
1ph 220-240V
External finish
Airflow (low-mid2-mid1-high)
17-18
Inverter Series
30
96
EXTERNAL
DIMENSIONS
Inverter Series
880
452
164.5
99.5
195
PUY-P42V/YKA PUY-P48V/YKA
OUTDOOR UNIT
2 U-shaped notched holes
(foundation bolt M10)
225
Control box
B
C
954 1000
1154 1200
D
860
1060
E
9
11
F
800
1000
G
858
1058
1400
1454 1500
1360
14
1300
1358
600
Installation feet
56
40
0
53
75
42
60
2 oval holes1236
(foundation bolt M10)
28
25
A
900
1100
225
19
Terminal block
(Indoor/Outdoor
connecting line)
370
417
67
356
330
Refrigerant piping
Flare connection (gas)
136
362
Earth terminal
Service panel
84 88
195
230
Air outlet
180
200
233
246
(liquid)
(gas)
When drain socket
is installed
(Drainage)
(liquid)
(gas)
When drain socket
is installed
(Drainage)
51
Air intake
85
442
369
680
476
680
Models
PCY-P18KA
PCY-P24KA
A
184
180
26
254
476
254
182
Air intake
57
A
B
233
246
57
Air outlet
10
5
450
236
1600
1493
632
1338
10
5
84 88
195
230
236
51
1280
1173
1198
Terminal connection
Left: Power supply wiring
Right: Indoor/Outdoor wiring
INDOOR UNIT
INDOOR UNIT
1050
PCY-P18KA PCY-P24KA
B
203
200
1518
Air intake
182
85
43
35
99.5
23
10
2x2- 2.9
Models
PEY-P18JA
PEY-P24JA
PEY-P30JA
PEY-P36JA
PEY-P42JA
PEY-P48JA
330
17.5
164.5
10
85 77
Service port
Terminal block
(Remote controller
transmission line)
732
700
32
23
40
122
C D
80 74
50
44
285
344.5
550
78 20
30
57
100
155
167
Refrigerant piping
Flare connection (liquid)
57
Service panel
Liquid refrigerant
pipe joint
800
10
217
250
281 298
14- 2.8
150 Burring hole
Cut out hole
178(Duct)
100
Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.
350
69
302.5
500
Bolt pitch for installation
33
241 258
175
Burring hole pitch
81
109
Liquid refrigerant pipe joint
150
24
Ceiling
Grille
70
105
156
190
+5
17 0
A
B
35
50~70
Models
PLY-P18BA
PLY-P24BA
PLY-P30BA
PLY-P36BA
PLY-P42BA
PLY-P48BA
2 holes 10 21
44
90 100 100 90
500
840
Drain pipe
377
Air
inlet
175
Service panel
23
Handle
100
130
284
170
140
60
Air
outlet
Air out
Air out
22.3
Air in
35
Refrigerant pipe
(liquid)
Refrigerant pipe
(gas)
40
280
D (Duct)
100x(E-1)=F
20~45
Suspension bolt
M10 or W3/8
Suspension bolt
lower edge
24
160
(7.5)
160
840
Air in
2 holes 10 X 21
Drain hole 42
40
Air in
Drain hole 42
Air in
20~45
160
950
840
150
90
C
D
15
20~45
Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block
187.5
OUTDOOR UNIT
400
A
B (Suspension bolt pitch)
C
Branch duct
hole
OUTDOOR UNIT
417.5
2xE- 2.9
950
Unit : mm
SUY-KA18VA
INDOOR UNIT
INDOOR UNIT
20~45
Fresh-air
intake hole
Unit : mm
19-20
A
1052
982
Gas refrigerant
pipe joint
21-22
Inverter Series
Rating conditions
Cooling - Indoor: 27C (80F) DB, 19C (66F) WB
Outdoor: 35C (95F) DB
Chemical properties
Outdoor
Indoor
18/24/30/36/42/48V
42/48Y
50Hz
Single-phase, 220-240V
Single-phase, 220-240V
Three-phase, 380-415V
60Hz
Single-phase, 220V
Single-phase, 220V
Three-phase, 380V
46C
46C
18C
-5C*
SUY-KA
Cooling
*With the optional Air Protection Guide, operational at outdoor temperatures as low as -15C is possible.
Composition (wt%)
54
54
52
52
50
50
48
48
46
46
44
44
42
40
Classification of refrigerant
Chlorine
42
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
40
0.9
The actual noise level depends on the distance from the unit and the acoustic environment.
0.8
0.7
Capacity
54
52
SUY-KA18
12
SUY-KA24/30/36
Thickness (mm)
Liquid: 6.35
t 0.8
Gas:
12.7
t 0.8
Liquid: 9.52
t 0.8
Gas: 15.88
t 1.0
Liquid: 9.52
t 0.8
Gas: 15.88
t 1.0
48
20
15
PUY-P42V/YKA
PUY-P48V/YKA
30
30
50
50
46
44
42
40
0.9
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
54
52
50
48
40
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
R22 (100)
Near-azeotropic
Single-component
No
Yes
72.8
86.5
-40.8
1,557/557
0.94
64
44.4
Vapor pressure
(25C,
MPa) <gauge>
0.6 0.5 0.4 0.3 0.2
0.1
0.0
Non-flammable
Non-flammable
0.055
1975
1700
Gas phase
Possible
Possible
R32/R125 (50/50)
-51.4
42
R22
46
44
R410A
*1 Base: CFC11 is 0.
*2 Base: CO2 is 0.
*3 Charging a liquid refrigerant rapidly may lock the compressor,
so add the refrigerant gradually.
Pressure properties
0.8
Refrigerant Piping
Previous refrigerant
(HCFCs)
Molecular weight
Inflammability
Composition change during
liquid-phase charging (R410A)
New refrigerant
(HFCs)
Factory
charged
Additional charge
Calculation
7m
10m
15m
20m
25m
30m
35m
40m
45m
50m
SUY-KA18
1.2
0.05
0.12
0.2
SUY-KA24
2.0
0.06
0.16
0.26
0.36
0.36
SUY-KA30
2.1
0.06
0.16
0.26
0.36
0.46
SUY-KA36
2.5
0.06
0.16
0.26
0.36
0.46
PUY-P42V/YKA
PUY-P48V/YKA
4.2
0.15
0.3
0.45
0.6
Xg = 15g/m (length-7) m
Xg = 20g/m (length-7) m
Pressure (gauge)
Temperature (C)
-20
0
20
40
60
65
R410A
MPa (gauge) / kgf
/ cm2 (gauge)
0.30 / 3.1
0.70 / 7.1
1.35 / 13.8
2.33 / 23.8
3.74 / 38.1
4.16 / 42.3
R22
MPa (gauge) / kgf
/ cm2 (gauge)
0.14 / 1.4
0.40 / 4.1
0.81 / 8.3
1.44 / 14.7
2.33 / 23.8
2.60 / 26.5
Xg=30g/m x (length-30)m
Handling Precautions
Mixing of refrigerants
Control of moisture
Control of contaminants
As the vapor pressure of R410A is 1.6 times higher than R22 at a given
temperature, use dedicated extension pipes for R410A. Tools dedicated
for R410A may also be required. Special care should be taken when
charging units with R410A.
If waste, air, flux, mineral oil, etc. get into the refrigerant system, it
accelerates the resolution or deterioration of the refrigerant oil, which
causes capillary clogging, deterioration of compressor insulation, etc.
Outdoor Unit
Installation Location
Inverter Series
23-24
Optional Parts
Part name
<S Series>
n SUY-KA24VA
n SUY-KA30VA
n SUY-KA36VA
100mm or more
100mm or more
350mm or more
500mm or more
200mm or more
PAR-SL97A-E
PLY-P / PEY-P
PAR-SA9CA-E
PEY-P
PAC-SA1ME-E
PLY-P
PAC-SH51SP-E
PLY-P
Multi-function casement
PAC-SH53TM-E
PLY-P
PAC-SE55RA-E
PAC-SF40RM-E
Remote sensor
PAC-SE41TS-E
Space panel
PAC-SH48AS-E
PLY-P
PAC-SA88HA-E
PAR-31MAA
PAR-21MAA
PAR-SL94B-E
PCY-P
PAC-725AD
15mm or more
Free
1,000mm or more
150mm or more
[ Notice ]
If there is any obstruction around the unit, check the condition details in the Data Book.
MAC-881SG
SUY-KA18
MAC-886SG-E
SUY-KA24/30/36
MSDD-50TR-E
PUY-P48
PAC-SG73RJ-E
PUY-P42/48
PAC-SG75RJ-E
PUY-P42/48
PAC-SG82DR-E
PUY-P42/48
PAC-SH96SG-E
PUY-P42/48
PAC-SH95AG-E
PUY-P42/48
Drain socket
PAC-SG61DS-E
PUY-P42/48
PAC-SH97DP-E
PUY-P42/48
M-Net converter
PAC-SF83MA-E
PUY-P42/48
PAC-SK52ST
PUY-P42/48
PAC-SC36NA-E
PUY-P42/48
Control/Service tool
PEY-P18
Shutter plate
Joint pipe
15mm or more
PLY-P
PAC-KE92TB-E
Distribution pipe
PCY-P30/36/42/48
PEY-P24
PAC-SH90KF-E
PAC-SH59KF-E
PEY-P30/36/42/48
PUY-P42, 48V/YKA
PLY-P
PCY-P18/24
PAC-KE93TB-E
n PUY-P42V/YKA
n PUY-P48V/YKA
PAR-SA9FA-E
PAC-SH89KF-E
PAC-KE94TB-E
<P Series>
PCY-P18
PLY-P
Filter box
PCY-P24/30/36/42/48
PAC-SH85DM-E
PAC-SH84DM-E
MAC-333IF-E
High-efficiency filter
SUY-KA18VA
Application name
PAC-SH65OF-E
n SUY-KA18VA
Model name
External/Input adapter
Notice
Do not install indoor units in areas where the emission of VOCs such as phthalate compounds and formaldehyde is known to
be high (e.g., mobile phone base stations) as this may result in a chemical reaction.
When installing, relocating or servicing air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.
Do not mix R410A with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, this may cause abnormal high pressure in the refrigerant lines and possibly result in an explosion
or other hazard.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, it could lead to a serious impediment to securing product safety.
Inverter Series
MEMO
Main Optional Parts
Part name
Description
Part name
Plug
(for directing
airflow)
Description
High-efficiency
filter element
i-see Sensor
corner panel
Shuttle Plate
Shuttle Plate
Joint Pipe
Multi-functional Casement
Casement for fresh-air intake and
attaching the high-efficiency filter
element (optional).
Multi-functional
casement
Joint pipe
Onsite pipe
Indoor unit
Insulator
Outdoor unit
Space Panel
Space Panel
Panel
Drain Pump
Drain Socket
Cap
Socket
Outdoor unit
Centralised drain pan
Base
(local construction)
Signal receiver
M-NET Converter
M-NET
Converter
Signal sender
Remote Sensor
Control/Service Tool
Remote sensor
Control/service tool
25-26
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
S-179-4-C9348-A SI-1403