Magnetic Overcurrent Circuit Breaker 808-...
Description
Single pole miniaturised magnetic circuit breakers with unique
high
-speed operating mechanism and push/pull on/off manual
actuation. Fitted with electrically separate excitation and switching
circuits, and one pair of auxiliary contacts which close when the
main circuit is open. Also suitable for impulse operation. Designed for
printed circuit board mounting. Low temperature sensitivity.
Typical applications
Printed circuit boards and components, safety and control systems.
808
Ordering information
Type No.
808 fast-acting
Manual release
H manual release facility
Current ratings
0.01...5 A
Technical data
808 - H - 5 A ordering example
NEW
Preferred types
Preferred types Standard current ratings (A)
0.02 0.05 0.1 0.3 0.4 0.5 0.6
808-H-
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal
resistance ()
Current
rating (A)
Internal
resistance ()
0.01
625
0.8
0.096
0.02
170
0.9
0.085
0.03
77
0.073
0.04
47
1.2
0.050
0.05
29.2
1.5
0.031
0.08
10.3
0.02
0.1
5.6
2.5
0.02
0.2
1.65
0.02
0.3
0.89
3.25
0.02
0.4
0.39
0.02
0.5
0.28
4.5
0.02
0.6
0.198
0.02
0.7
0.143
Approvals
Authority
Voltage ratings
Current ratings
CSA
AC 120 V; DC 60 V
0.01...5 A
UL
DC 60 V
AC 12 V
0.01...5 A
0.01...5 A
Issue D
Voltage rating
DC 24 V (higher voltages to special order)
UL: AC 120 V; DC 60 V
Current ratings
0.01...5 A
(higher current ratings to special order)
Max. continuous load
excitation circuit (2-3) 2.65 x IN
Max. continuous load
switching circuit 6-7
auxiliary circuit 4-5 5 A
6,000 operations
Typical life
at 5 A for switching circuit
Ambient temperature
-30...+70 C (-22...+158 F)
Insulation co-ordination rated impulse
pollution
(IEC 60664-1)
withstand voltage degree
1.5 kV
2
Dielectric strength
test voltage
(UL 1077)
operating area
AC 1,240 V
excitation to
switching circuit
AC 1,240 V
excitation to
auxiliary circuit
AC 1,240 V
Insulation resistance
> 100 M (DC 500 V)
Interrupting capacity
(o-o-o)
100 A
Interrupting capacity
(UL 1077)
2,000 A AC 120 V
1,000 A DC 60 V
Degree of protection
operating area IP30
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
3 g (57-500 Hz), 0.23 mm (10-57 Hz),
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
25 g (11 ms)
Shock
to IEC 60068-2-27, test Ea
Corrosion
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 10 g
www.e-t-a.de
4-5
Magnetic Overcurrent Circuit Breaker 808-...
Dimensions
Internal connection diagram
20
.787
9.3
.366
4
.157
2-3: excitation circuit
6-7: switching circuit
4-5: auxiliary circuit
5
.197
5
.197
2.5 ON
.098
7.5 OFF
.295
808-H
3
+
14
.551
30
1.18
15
.591
0.6
.024
0.5
.020
10
.394
15.5
.610
Typical time/current characteristics at +23 C/+73.4 F
10000
Trip time in milliseconds
1000
100
10
0.1
6 8 10
20
40
... times rated current
This is a metric design and millimeter dimensions take precedence ( mm )
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
4-6
www.e-t-a.de
Issue D