Sarawak Electrical Rates 2014

This document provides a schedule of rates for electrical installation works in Sarawak, Malaysia for the year 2014. It includes rates for various electrical wiring points like lighting points, fan points, switched socket outlets, TV/telephone points, and isolator points. The rates are provided by JKR Sarawak and include supply, installation, testing and commissioning of materials. A location factor percentage is also included to account for different installation locations in Sarawak.

Uploaded by

Chua Siok Shyen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
236 views15 pages

Sarawak Electrical Rates 2014

This document provides a schedule of rates for electrical installation works in Sarawak, Malaysia for the year 2014. It includes rates for various electrical wiring points like lighting points, fan points, switched socket outlets, TV/telephone points, and isolator points. The rates are provided by JKR Sarawak and include supply, installation, testing and commissioning of materials. A location factor percentage is also included to account for different installation locations in Sarawak.

Uploaded by

Chua Siok Shyen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

SCHEDULE OF RATES FOR

ELE CT R ICAL IN STA LLA TIO N


WORKS IN SARAWAK 2014

JKR Sarawak
December 2014

Notes to tenderers:
1.

This is only a cover page for this document. Please obtain the full set from the
JKR Sarawak webpage or any JKR Sarawak office.

2.

The Location Factor from base at Kuching City for this tender is ____ %
and is the percentage over all the items and rates as listed in this Schedule of
Rates to be used for the purposes as stated in the tender documents.

3.

Any attempt to amend / change / correct etc. this percentage by the


tenderer shall cause the tender to be disqualified.

L O C AT I O N F AC T O R FR O M B A S E AT K U CH I N G CI T Y
(To be read together with the Rules of determining the Location Factor)
Kuching

Samarahan

Betong

Kapit

City

0%

Padawan

District

15%

2%

Lubok Antu

20%

Santubong

3%

Lingga

20%

Siburan

3%

Pantu

13%

Bau

5%

Engkilili

18%

Lundu

8%

Sematan

9%

Skrang

15%

District

2%

District

12%

Serian

5%

Kem Bt 10 & 14

13%

Simunjan

12%

Durin

15%

Sebuyau

15%

Bawang Assan

13%

Asajaya

10%

Sungai Assan

13%

Sadong Jaya

12%

Kanowit

16%

Tebedu

8%

Machan

16%

Tebakang

8%

Nibong Tada

15%

Balai Ringin

8%

Nanga Tada

17%

Nanga Dap

20%

Nanga Ngemah

20%

Sri Aman

Sibu

District

20%

Nanga Ngungun

20%

Spaoh

20%

Nanga Poi

22%

Debak

20%

Nanga Jagau

40%

Pusa

21%

Selangau

18%

Beladin

20%

Ulu Balingian

20%

Maludam

22%

Arip

22%

Saratok

20%

Stapang

16%

Roban

20%

Rassau

22%

Kabong

20%

District

30%

District

15%

Song

25%

Tatau

20%

Belaga

70%

Sebauh

23%

Sungai Asap

25%

Bintulu

L O C AT I O N F AC T O R FR O M B A S E AT K U CH I N G CI T Y
(To be read together with the Rules of determining the Location Factor)
Mukah

Sarikei

District

20%

City

15%

Dalat

20%

Subis

15%

Oya

20%

Bekenu

15%

Igan

18%

Marudi

25%

Balingian

23%

Long Lama

40%

Kuala Balingian

23%

Beluru

22%

Semop

30%

Matu

25%

District

30%

Betanak

30%

Lawas

28%

Daro

25%

Bruit

30%

Tanjung Manis

18%

District

18%

Bintangor

18%

Pakan

20%

Selalang

20%

Julau

20%

Meluan

22%

Ulu Entabai

23%

Engkamop

30%

Nanga Wak

15%

Nanga Entabai

14%

Miri

Limbang

R U L E S O F DE T E R MI NI NG T H E L O C AT I O N FA C T O R
1.

The % factors as stated are for those projects accessible by motorized vehicles within
15km radius from the location shown.

2.

Where the project site is beyond 15km radius of the above stated locations, these
additional % factors shall be added on to those percentages stated above:
% addition
(i)
( ii )
( iii )
( iv )
(v)

3.

> 15km
> 45km
> 90km
> 135km
> 180km

< 45km
< 90km
< 135km
< 180km
< 220km

5%
10%
15%
20%
25%

Where the project sites are accessible only by waterway


(i)
( ii )
( iii )
( iv )
(v)
( vi )

areas within 15 km radius


areas within 30 km radius
areas within 60 km radius
areas within 90 km radius
areas within 120 km radius
areas within 150 km radius

0%
5%
10%
15%
20%
25%

4.

Where the project sites can only be accessible by air, the location factor shall be doubled
over the value obtained from that by motorized vehicles.

5.

Where the project sites can only be accessible by foot, the location factor shall be 50%
over the value obtained from that by authorized vehicles

6.

Where in determining the locations factor and two or more factors and radial distances
are equally applicable, the lower in each case shall be used.

7.

Where in determining the location factor and two or more factors and radial distances
by the rules above whereby there can be a combination due to accessibility, say partly
land and partly waterway or partly waterway and partly by foot, there shall be a
combination of the rules according to the radial distance from the nearest locations
stated above.

8.

Where in determining the location factor and the Site for the project lies within two
more radial distances, the addition % for the radial distance within which more than
50% of the Site lies shall be used.

P R E AM B L E S

1. All rates given shall include supply, delivery, installation, testing and
commissioning and shall include associated accessories and fitting.
2. Rate per point applies for the stated route length. For longer route length, the
rate per metre, derived from the rate per point shall be used.
3. All rates shall be used and read together with the Location Factor from base
at Kuching City.
4. All descriptions are to be read with reference to the Standard Electrical
Installation Specification (Latest Version) and the following :
a) All rates herein shall be held to include for supply and delivery to site, wastage on
materials, carriage and cartage, carrying in and return of empties, hoisting, setting,
fitting and fixing in position, making good and all other labours and everything else
necessary (including any custom duties, etc.) for the proper completion of each item and
for establishment charges and profit.
b) Rates for each item of paving shall be held to include for all rounded angles, arrises and
making good and any other sundry items of alike nature.
c) Rates for mild steel tubing are to include for short running lengths, sockets, backnuts,
elbows and bends.

SOR for Electrical Installation Works 2014

GENERAL WIRING
Item
No.

Description

Unit

Rate (RM)

Concealed conduit wiring c/w metal clad switch and socket plates
and accessories : Wiring shall be run concealed, in Class B
galvanized steel conduits and complete with GS conduit boxes let
into cement or timber wall, or partition, together with all necessary
metal clad lighting switch plates, switched socket plates, isolators
and accessories. Wiring shall be 1.5 mm2 PVC for fan and lighting
2
points, 2.5 mm PVC for 13A and 15A switched sockets. 13A 3-pin
switched socket points shall be wired in ring circuit/s. Accepted
brands Clipsal, PDL or MEM.
1

Lighting Point wired from nearest switch : Rate per point applies up to
route length of 10 metres.

(i)

6A 1-way lighting point c/w switch.

Per point

102.20

(ii)

6A 2-way lighting point c/w switch.

Per point

139.90

(iii)

6A intermediate lighting point c/w switch.

Per point

161.40

Per point

53.80

Lighting Point wired from nearest lighting point (sharing same switch) up
to 4 metre route length.

(i)

6A 1-way lighting point.

Fan Points : wired from nearest switch (up to 10 metres route length).

(i)

Ceiling fan point c/w 6A switch.

Per fan point

102.20

(ii)

Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and
opening for fan.

Per fan point

102.20

Switched Socket Outlets :

(i)

13A 3-pin switched socket point in ring circuit :


1 gang (up to 10 metre route length).

Per 1-gang
socket pt.

139.90

(ii)

13A 3-pin switched socket point in ring circuit :


2 gang (up to 10 metre route length).

Per 2-gang
socket pt.

188.30

15A 3-pin switched socket point (up to 15 metre route length).

Per point

236.70

(iii)

Per point

269.00

Per isolator

312.00

Isolators and Water Heater Points : (up to 15 metre route length).

(i)

Water heater point c/w 20A double pole switch with neon light indicator,
2
4mm PVC cable.

(ii)

20A single phase isolator point 4 mm cabling.

(iii)

30A single phase isolator point 6 mm cabling.

Per isolator

430.40

(iv)

20A TPN isolator point 4 mm cabling.

Per isolator

451.90

(v)

30A TPN isolator point 6 mm cabling.

Per isolator

613.30

SOR ELEC 2014/Page 1 of 10

'

GENERAL WIRING...(CONT D)
Item
No.

Description

Unit

Rate (RM)

TV / Telephone Point : (up to 15 metre route length).

(i)

1 pair c/w socket and 2 x 0.63 mm cable.

Per point

96.90

(ii)

2 pairs c/w socket and 4 x 0.63 mm cable.

Per point

118.40

(iii)

TV antennae point c/w 5c / 2v cable and TV socket.

Per point

96.90

Miscellaneous Wiring Point : (up to 15 metre route length).

(i)

Single phase power supply to fire protection control panel 2.5 mm PVC
cabling.

(ii)

Lighting point for emergency lighting or keluar sign c/w 1.5 mm cable.

Per point

231.30

Per point

96.90

Surface conduit wiring c/w metal clad switch and socket plates and
accessories : Wiring shall be run on surface, in Class B galvanized
steel conduits and complete with GS conduit boxes, together with all
necessary metal clad lighting switch plates, switched socket plates,
isolators and accessories. Wiring shall be 1.5 mm PVC for fan and
lighting points, 2.5 mm PVC for 13A and 15A switched sockets. 13A
3-pin switched socket points shall be wired in ring circuit/s.
Accepted brands Clipsal, PDL or MEM.
8

Lighting Point wired from nearest switch : Rate per point applies up to
route length of 10 metres.

(i)

6A 1-way lighting point c/w switch.

Per point

91.50

(ii)

6A 2-way lighting point c/w switch.

Per point

134.50

(iii)

6A intermediate lighting point c/w switch.

Per point

150.70

Lighting Point wired from nearest lighting point (sharing same switch)

Per point

48.50

up to 4 metre route length.


(i)

6A 1-way lighting point.

10

Fan Points : wired from nearest switch (up to 10 metres route length) .

(i)

Ceiling fan point c/w 6A switch.

Per fan point

91.50

(ii)

Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and
opening for fan.

Per fan point

91.50

11

Switched Socket Outlets :

(i)

13A 3-pin switched socket point in ring circuit :


1 gang (up to 10 metre route length).

Per 1-gang
socket pt.

(ii)

13A 3-pin switched socket point in ring circuit :


2 gang (up to 10 metre route length).

Per 2-gang
socket pt.

SOR ELEC 2014/Page 2 of 10

139.90

182.90

'

GENERAL WIRING...(CONT D)
Item
No.

Description

Unit

Rate (RM)

Per point

193.70

'

11

Switched Socket Outlets : (Cont d)

(iii)

15A 3-pin switched socket point (up to 15 metre route length).

12

Isolators and Water Heater Points : (up to 15 metre route length).

(i)

Water heater point c/w 20A double pole switch with neon light indicator,
4mm PVC cable.

(ii)

20A single phase isolator point 4 mm cabling.

(iii)

30A single phase isolator point 6 mm cabling.

Per point

258.20

Per isolator

290.50

Per isolator

392.70

(iv)

20A TPN isolator point 4 mm cabling.

Per isolator

387.30

(v)

30A TPN isolator point 6 mm cabling.

Per isolator

548.70

13

TV / Telephone Point : (up to 15 metre route length).

(i)

1 pair c/w socket and 2 x 0.63 mm cable.

(ii)

Per point

86.10

2 pairs c/w socket and 4 x 0.63 mm cable.

Per point

107.60

(iii)

TV antennae point c/w 5c / 2v cable and TV socket.

Per point

86.10

14

Miscellaneous Wiring Point : (up to 15 metre route length).

(i)

Single phase power supply to fire protection control panel 2.5 mm PVC
cabling.

(ii)

Lighting point for emergency lighting or keluar sign c/w 1.5 mm cable.

Per point
Per point

215.20

86.10

Surface Wiring : Wiring shall be run surface on batten wood


complete with all necessary PVC moulded conduit boxes, lighting
switch plates, 13A or 15A switched socket plates and accessories.
2
2
Wiring shall be 1.5 mm PVC/PVC for fan and lighting points, 2.5 mm
PVC/PVC for 13A and 15A switched sockets. 13A 3-pin switched
socket points shall be wired in ring circuit/s. Accepted brands
Clipsal, PDL or MEM.
15

Lighting Point wired from nearest switch : Rate per point applies up to
route length of 10 metres.

80.70

(i)

6A 1-way lighting point c/w switch.

Per point

(ii)

6A 2-way lighting point c/w switch.

Per point

118.40

(iii)

6A intermediate lighting point c/w switch.

Per point

139.90

16

Lighting Point wired from nearest lighting point (sharing same switch) up
to 4 metre route length.

(i)

Per point

6A 1-way lighting point.


SOR ELEC 2014/Page 3 of 10

48.50

'

GENERAL WIRING...(CONT D)
Description

Item
No.

Unit

Rate (RM)

17

Fan Points : wired from nearest switch (up to 10 metres route length).

(i)

Ceiling fan point c/w 6A switch, ceiling rose and hardwood block for fan
speed regulator.

Per fan point

80.70

Extractor fan point c/w 6A switch. (cost excludes hardwood frame and
opening for fan).

Per fan point

80.70

(ii)

18

Switched Socket Outlets and Water Heater Point :

(i)

13A 3-pin switched socket point in ring circuit :


1 gang (up to 10 metre route length).

Per 1-gang
socket pt.

118.40

(ii)

13A 3-pin switched socket point in ring circuit :


2 gang (up to 10 metre route length).

Per 2-gang
socket pt.

161.40

(iii)

15A 3-pin switched socket point (up to 15 metre route length).

Per point

(iv)

Water heater point c/w 20A double pole switch with neon light indicator, 4
mm PVC cable (up to 15 metre route length).

Per point

226.00

Per metre

32.30

Per metre

43.10

Per metre

53.80

Per metre

75.40

Per point

96.90

19

161.40

Mains and Sub-mains Wiring : from SESCo supply intake to distribution


boards/consumer units, through meter and cut-outs, using surface wiring.
2

(i)

1-phase 2 x 16 mm 1 core PVC insulated and sheathed cables.

(ii)

1-phase 2 x 25 mm 1 core PVC insulated and sheathed cables.

(iii)

3-phase 4 x 16 mm 1 core PVC insulated and sheathed cables.

(iv)

3-phase 4 x 25 mm 1 core PVC insulated and sheathed cables.


Concealed conduit wiring c/w plastic moulded switch and socket
plates and accessories : Wiring shall be run concealed, in Class B
galvanized steel conduits and complete with GS conduit boxes let
into cement or timber wall, or partition, together with all necessary
PVC moulded lighting switch plates, switched socket plates and
accessories. Wiring shall be 1.5 mm PVC for fan and lighting points,
2.5 mm PVC for 13A and 15A switched sockets. 13A 3-pin switched
socket points shall be wired in ring circuit/s. Accepted brands
Clipsal, PDL or MEM.

20

Lighting Point wired from nearest switch : Rate per point applies up to
route length of 10 metres.

(i)

6A 1-way lighting point c/w switch.

(ii)

6A 2-way lighting point c/w switch.

Per point

134.50

(iii)

6A intermediate lighting point c/w switch.

Per point

150.70

SOR ELEC 2014/Page 4 of 10

'

GENERAL WIRING...(CONT D)
Item
No.

Description

21

Lighting Point wired from nearest lighting point (sharing same switch) up

Unit

Rate (RM)

Per point

48.50

to 4 metre route length.


(i)

6A 1-way lighting point.

22

Fan Points : wired from nearest switch (up to 10 metres route length).

(i)

Ceiling fan point c/w 6A switch.

Per fan point

96.90

(ii)

Extractor fan point c/w 6A switch. Cost excludes hard-wood frame and
opening for fan.

Per fan point

96.90

23

Switched Socket Outlets :

(i)

13A 3-pin switched socket point in ring circuit :


1 gang (up to 10 metre route length).

Per 1-gang
socket pt.

129.10

(ii)

13A 3-pin switched socket point in ring circuit :


2 gang (up to 10 metre route length).

Per 2-gang
socket pt.

172.20

15A 3-pin switched socket point (up to 15 metre route length).

Per point

226.00

(iii)
24

TV / Telephone Point : (up to 15 metre route length).

(i)

1 pair c/w socket and 2 x 0.63 mm cable.

Per point

86.10

(ii)

2 pairs c/w socket and 4 x 0.63 mm cable.

Per point

107.60

(iii)

TV antennae point c/w 5c / 2v cable and TV socket.

Per point

86.10

25

Earthing Leads : from distribution board to earth electrode-green PVC


insulated copper cable protected by class 'B' galvanized steel conduits to
be installed below surface of hard-standing, cement floor, corridor, apron,
etc. (up to 10 metres route length)

(i)

16mm PVC insulated

(ii)

25mm PVC insulated

Per lot
Per lot

SOR ELEC 2014/Page 5 of 10

269.00
344.30

LIGHTING FITTINGS, FANS AND ACCESSORIES

Item
No.

Description

Unit

Rate (RM)

Accessories : Cost for extractor fan hole openings in brick or


wooden walls shall include cost of making the hole together with

2 x 4 hardwood frame. Size of opening shall be appropriate for the


diameter of fans indicated.
1

Installation of fan hook from cement floor slab.

Per unit

34.50

Installation of fan hook from timber floor joist.

Per unit

28.00

Extractor fan hole opening in brick wall for extractor fan of diameter from
400 to 500 mm (16 to 20).

Per no.

209.80

Extractor fan hole opening in brick wall for extractor fan of diameter from
200 to 350 mm (8 to 14).

Per no.

172.20

Extractor fan hole opening in wooden wall for extractor fan of diameter
from 400 to 500 mm (16 to 20).

Per no.

142.10

Extractor fan hole opening in wooden wall for extractor fan of diameter
from 200 to 350 mm (8 to 14).

Per no.

123.80

Extractor fan hole opening in glass panel for extractor fan of diameter from
200 to 350 mm (8 to 14).

Per no.

158.20

Fans : Cost includes supply and installation of fittings. Ceiling fans


and oscillating fans shall have individual 3-speed (low/medium/high)
regulators. Wall fans shall feature pull cord oscillation control and 3speed (low/medium/high) regulators. Ceiling fans shall have safety
steel suspension wire and safe power disconnection feature. Cost of
making fan hole opening is priced separately. Acceptable brands
Khind, National, KDK or Sanyo
8

Ceiling fan 1,520 mm (60) diameter sweep.

Per unit

Ceiling mount oscillating fan 500 mm (20) dia.

Per unit

349.70

10

Ceiling mount oscillating fan 400 mm (16) dia.

Per unit

279.80

11

Wall mount fan 500 mm (20) diameter.

Per unit

279.80

12

Wall mount fan 400 mm (16) diameter.

Per unit

247.50

13

Extractor fan 500 mm (20) diameter.

Per unit

279.80

14

Extractor fan 400 mm (16) diameter.

Per unit

236.70

15

Extractor fan 350 mm (14) diameter.

Per unit

204.40

16

Extractor fan 300 mm (12) diameter.

Per unit

182.90

17

Extractor fan 200 mm (8) diameter.

Per unit

158.20

SOR ELECT 2014/Page 6 of 10

175.40

'

LIGHTING FITTINGS, FANS AND ACCESSORIES...(CONT D)

Item
No.

Description

Unit

Rate (RM)

Fluorescent Fittings : All fluorescent fittings shall be complete with


low loss polyester resin impregnated ballasts of loss not exceeding
6.5 watts, power factor correction capacitor to correct to power
factor of not less than 0.85, starter, fluorescent tubes and holders.
Cost includes supply and installation. Acceptable brands - LHL,
Britelite, Davis, Jetlite, National, GEC, Philip, Thorn.
18

Channel Fluorescent Fitting 1 x 18W / 36 W Surface Mount

(i)

1 x 18 watt bare channel fluorescent fitting.

Per unit

33.40

(ii)

1 x 18 watt channel fluorescent fitting c/w wire guard.

Per unit

61.40

(iii)

1 x 36 watt bare channel fluorescent fitting.

Per unit

38.80

(iv)

1 x 36 watt bare channel fluorescent fitting c/w metal angle reflector.

Per unit

73.20

(v)

1 x 36 watt bare channel fluorescent fitting c/w suspension rod.

Per unit

78.60

(vi)

1 x 36 watt channel fluorescent fitting c/w wire guard.

Per unit

67.80

(vii)

1 x 36 watt channel fluorescent fitting c/w wire guard and suspension rod.

Per unit

96.90

19

Channel Fluorescent Fitting 2 x 36 W Surface Mount

(i)

2 x 36 watt bare channel fluorescent fitting.

Per unit

67.80

(ii)

2 x 36 watt bare channel fluorescent fitting c/w suspension rod.

Per unit

90.40

(iii)

2 x 36 watt channel fluorescent fitting c/w diakon diffuser.

Per unit

101.20

(iv)

2 x 36 watt channel fluorescent fitting c/w diakon diffuser and suspension


rod.

Per unit

123.80

(v)

2 x 36 watt bare channel fluorescent fitting c/w metal trough reflectors.

Per unit

95.80

(vi)

2 x 36 watt bare channel fluorescent fitting c/w metal trough reflectors and
suspension rod.

Per unit

129.10

20

Modular type Fluorescent Fittings Recessed Fittings

(i)

2 x 18 watt modular recessed (2 x 2) fluorescent fitting c/w aluminum


parabolic reflector and baffles.

Per unit

158.20

2 x 36 watt modular recessed (2 x 4) fluorescent fitting c/w aluminum


parabolic reflector and baffles.

Per unit

191.50

3 x 36 watt modular recessed (2 x 4) fluorescent fitting c/w aluminum


parabolic reflector and louvers.

Per unit

231.30

(ii)

(iii)

SOR ELECT 2014/Page 7 of 10

'

LIGHTING FITTINGS, FANS AND ACCESSORIES...(CONT D)

Item
No.

Description

Unit

Rate (RM)

158.20

21

Modular type Fluorescent Fittings Surface Fittings

(i)

2 x 18 watt modular recessed (2 x 2) fluorescent fitting c/w aluminum


parabolic reflector and baffles.

Per unit

2 x 36 watt modular surface (2 x 4) fluorescent fitting c/w aluminum


parabolic reflector and baffles.

Per unit

3 x 36 watt modular surface (2 x 4) fluorescent fitting c/w aluminum


parabolic reflector and louvers.

Per unit

219.50

Per unit

328.20

Per unit

406.70

Per unit

327.10

Per unit

406.70

(ii)

(iii)

22

Self-contained Modular type Fluorescent Fittings c/w Battery & Charger

(i)

2 x 18 watt modular recessed (2 x 2) fluorescent fitting c/w aluminum


parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid
battery, charger and control unit.
2 x 36 watt modular recessed (2 x 4) fluorescent fitting c/w aluminum
parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid
battery, charger and control unit.

(ii)

2 x 18 watt modular surface (2 x 2) fluorescent fitting c/w aluminum


parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid
battery, charger and control unit.
2 x 18 watt modular recessed (2 x 4) fluorescent fitting c/w aluminum
parabolic reflector and baffles, 3-hr maintenance free sealed lead-acid
battery, charger and control unit.

(iii)

(iv)

191.50

Miscellaneous Lighting Fittings : Cost includes supply and


installation of fittings. Installation for floodlight fittings are in
reference to standard installation on walls accessible by ladder.
Accepted brands for flood lights Nikkon, Thorn or Philips.
Emergency Light / KELUAR Sign Fittings : self contained c/w sealed 3-hr

23

maintenance free sealed lead-acid battery, charger and control unit c/w
trickle charging & over-charge protection.
(i)
(ii)
(iii)

Self contained 2 x 8 watts emergency lighting fitting.

KELUAR sign fluorescent type, single sided.


KELUAR sign fluorescent type, double sided.

(iv) KELUAR c/w direction signage single sided fluorescent type.


(v)

KELUAR c/w direction signage double sided fluorescent type.

(vi) KELUAR sign LED type, single sided.


(vii) KELUAR sign LED type, double sided.
(viii) KELUAR c/w direction signage single sided LED type.
(ix) KELUAR c/w direction signage double sided LED type.
SOR ELECT 2014/Page 8 of 10

123.80
Per unit
Per unit

180.80

Per unit

224.00

Per unit

186.20

Per unit

236.70

Per unit

186.20

Per unit

196.90

Per unit

203.40

Per unit

215.20

'

LIGHTING FITTINGS, FANS AND ACCESSORIES...(CONT D)

Item
No.

Description

24

Lamp-shade c/w incandescent lamp

(i)

Coolicon lamp shade, lamp holder c/w 40W, 60W or 100 W incandescent
lamp.

Unit

Rate (RM)

Per fitting

17.30

67.80

25

Flood-light / Spot-light Fittings

(i)

Outdoor type spot light fitting c/w metal lamp holder and PAR 38 150 W
lamp of various colours.

Per fitting

Outdoor type metal halide floodlight fittings c/w 400 W lamp, control gear
and power factor correction capacitor.

Per fitting

Outdoor type metal halide floodlight fittings c/w 250 W lamp, control gear
and power factor correction capacitor.

Per fitting

451.90

Outdoor type high pressure sodium floodlight fittings c/w 400 W lamp,
control gear and power factor correction capacitor.

Per fitting

542.20

Outdoor type high pressure sodium floodlight fittings c/w 250 W lamp,
control gear and power factor correction capacitor.

Per fitting

462.60

Per fitting

90.40

Per fitting

45.20

(ii)

(iii)

(iv)

(v)

26

Bulkhead Fittings

(i)

Bulkhead fitting pressure die-cast aluminium alloy type c/w 40W, 60W or
100W incandescent lamp, glass cover and wire guard.

(ii)

Bulkhead fitting plastic die-cast type c/w 40W, 60W or 100W


incandescent lamp, plastic cover and wire guard.

SOR ELECT 2014/Page 9 of 10

519.70

DISTRIBUTION BOARDS & CONSUMER UNITS

Item
No.

Description

Unit

Rate (RM)

Distribution Boards & Consumer Units : Distribution boards and


consumer units shall be metal clad type c/w isolator, residual current
circuit breaker (RCCB) and assortment of miniature circuit breakers
(mcb). Isolators and RCCB shall be double pole and four pole
respectively for single phase and three phase units. Isolators shall be
rated at 60A min. Miniature circuit breakers shall be single pole 6A,
15A, or 32A as required, of minimum breaking capacity 5 kA, and
tripping curve Type B. Comb-type busbars are not accepted. Units
shall feature DIN rail mounting, for plug-in, wired-out mcb. Accepted
brands MEM, Hager, L&T, LKH
1

Single Phase Consumer Units

(i)

4 way ( RCCB : 40A, 100 mA sensitivity).

Per set

290.50

(ii)

4 way ( RCCB : 60A, 100 mA sensitivity).

Per set

338.90

(iii)

6 way ( RCCB : 40A, 100 mA sensitivity).

Per set

371.20

(iv)

6 way ( RCCB : 60A, 100 mA sensitivity).

Per set

441.10

(v)

8 way ( RCCB : 40A, 100 mA sensitivity).

Per set

441.10

(vi)

8 way ( RCCB : 60A, 100 mA sensitivity).

Per set

494.90

Three Phase Distribution Boards c/w RCCB 100 mA sensitivity

(i)

4 way ( RCCB : 40A, 100 mA sensitivity).

Per set

979.00

(ii)

4 way ( RCCB : 60A, 100 mA sensitivity).

Per set

1,032.80

(iii)

6 way ( RCCB : 40A, 100 mA sensitivity).

Per set

1,075.80

(iv)

6 way ( RCCB : 60A, 100 mA sensitivity).

Per set

1,108.10

(v)

8 way ( RCCB : 40A, 100 mA sensitivity).

Per set

1,253.40

(vi)

8 way ( RCCB : 60A, 100 mA sensitivity).

Per set

1,377.10

Three Phase Distribution Boards c/w RCCB 300 mA sensitivity

(i)

4 way ( RCCB : 40A, 300 mA sensitivity).

Per set

936.00

(ii)

4 way ( RCCB : 60A, 300 mA sensitivity).

Per set

979.00

(iii)

6 way ( RCCB : 40A, 300 mA sensitivity).

Per set

1,016.70

(iv)

6 way ( RCCB : 60A, 300 mA sensitivity).

Per set

1,065.10

(v)

8 way ( RCCB : 40A, 300 mA sensitivity).

Per set

1,215.70

(vi)

8 way ( RCCB : 60A, 300 mA sensitivity).

Per set

1,301.80