Product and Technical Specifications
The ACIST | CVi Contrast Delivery System is intended to be used for controlled infusion
of radiopaque contrast media for angiographic procedures.
CVi system
Flow Rates
Contrast:
Saline:
Volume
User-Responsive, pre-set Variable and Fixed rates from 0.8 to 40 ml/sec, in 0.10 ml/sec increments
Fixed rate: 1.6 ml/sec
User-Responsive, pre-set limits with variable range of 0.8 to 99.9 ml, in 0.1 ml/sec increments
Pressure Limits
User defined from 200 to 1200 psi
Fill Rate
Manual or automatic refill of 3 ml/sec
Rise Time
User-defined 0 to 1 sec, in 0.1 sec increments
Program Routine Injection Modes
Cardiac: LCA, RCA, LV/Ao, and User Defined
Monitoring Sensors
Peripheral Vascular: Pigtail, Selective, Microcatheter, and User Defined
Air Column Detect*
Isolation manifold
Contrast Source Empty
Imaging Interface Synchronization**
Contrast Reservoir Refill and Contrast Source Isolation
Able to synchronize with most brands of X-ray imaging equipment
Injection Delay** or X-ray Delay**
099.9 sec
KVO Feature***
Range of 0.1 to 10 ml/min with 20 minute timeout; maximum of 200 ml of saline dispensed
Control Panel
27 cm (10.5 inches) Color Touch Screen
Flexible Mounting Configurations
Table Mount with adjustable arm or stationary stem
Pedestal Cart Dimensions
Contrast Reservoir
Consumable Kit Configurations
Contrast Reservoir (5 patient):
AngioTouch Hand
Controller & Tubing:
Pedestal Cart
Wheelbase footprint 53.3 63.5 cm (21 25 inches), height 91.4 cm (36 inches)
100 ml
Contrast Reservoir with contrast tubing spike and clamp (for use in up to 5 patient cases)
Automated Isolation Manifold:
Component Weights
Power Requirements
AngioTouch hand controller, injection line tubing, and 3-way stopcock
Integrated system with automated isolation-manifold, low-pressure tubing and saline spike, and
supplied pressure transducer cartridge; kits with no transducer also available
Power supply 5.5 kg (12 lb), control panel and stem 3.2 kg (7 lb), pedestal cart 10 kg (22 lb),
injector head 20.4 kg (45 lb), adjustable arm 0.66 kg (1.45 lb)
Factory selectable: 100 to 120 VAC, 5060 Hz, 10 A maximum or 200 to 240 VAC, 5060 Hz,
5 A maximum
* The air column detection sensor is designed to aid the user in the detection of air columns in the injection line, but it is not designed to replace the vigilance and care
required of the operator in visually inspecting for air and clearing air
** Available in synchronized peripheral mode
*** Available in peripheral mode
Contact us in the US:
7905 Fuller Road
Eden Prairie, Minnesota 55344
Phone: (952) 995-9300
Fax: (952) 941-4648
USA Toll-free: 1-888-667-6648
Contact us in the EU:
ACIST Europe B.V.
Renier Nafzgerstraat 114
6221 KL Maastricht
The Netherlands
Phone: +31 43 354 5030
Fax: +31 43 354 5035
Contact us in Asia:
ACIST Shanghai Trading Co., Ltd
Room 501 Gangtai Plaza
No. 700 Yan An East Road
Shanghai, China 200001
Phone: +86 21 5385 1515
ACIST CVi and AngioTouch are registered trademarks of ACIST Medical Systems, Inc., registered in the US. ACIST Medical Systems, Inc., reserves the right to modify
the specifications and features described herein, or discontinue manufacture of the product described at any time without prior notice or obligation. Please contact
your authorized ACIST representative for the most current information. 2014 ACIST Medical Systems, Inc. All Rights Reserved. P/N: 0214.322.02
Visit our website:
www.acist.com
The ACIST | CVi Contrast Delivery System
Simplifying Contrast Injection
Bracco Group
Simplifying Procedures
The ACIST|CVi Contrast Delivery System the
sophisticated system that simplifies contrast injection
for ALL your interventional and diagnostic cardiology
procedures, from small injections in the coronary
arteries, to large volumes in the ventricles and
peripheral vasculature.
Simplifying Control
The ACIST CVi systems innovative design helps
make it simple to operate, allowing you to
generate quality images and to focus on whats
important your patient and the procedure.
2 | The ACIST | CVi Contrast Delivery System
The ACIST | CVi Contrast Delivery System | 3
Simplifying Patient
Care
The ACIST CVi boasts an array of advanced, built-in
safety features that provide continuous and automated
monitoring of all critical systems functions, and can
deliver contrast with ease even through 4Fr catheters2.
By reducing overall procedure time the ACIST CVi helps
to reduce radiation exposure3.
We are passionate about patient care.
The ACIST CVi system has been shown
to reduce procedure time and the volume
of contrast delivered to the patient by
providing precise contrast delivery.
3
4
5
1 T he AngioTouch hand controller allows real-time,
variable-flow control of the contrast injection rate for precise
and consistent contrast administration, and has been shown
to reduce per-patient contrast dosage by up to 20%1
The touch screen monitor provides intuitive on-screen
prompts for set-up, adjustable injection volume and flow rate
limits, contrast tracking information, and real-time readout for
continuous system and procedure monitoring
The built-in air column detection sensor alerts the clinician
and stops the injection if air is detected in the single-use
patient tubing connected to the catheter*
The five-patient, isolated contrast reservoir with rapid
automatic refill can reduce contrast waste and save time
between cases
In-line, continuous hemodynamic monitoring provides a
real-time pressure reading, and the automated isolation
manifold provides a barrier to the contrast reservoir
4 | The ACIST | CVi Contrast Delivery System
*The air column detection sensor is designed to aid the user in the detection
of air columns in the injection line, but it is not designed to replace the
vigilance and care required of the operator in visually inspecting for air
and clearing air
1. Anne G, Gruberg L, Huber A, et al. J Invasive Cardiol. 2004;16(7):360362
2. Khoukaz S, Kern MJ, Bitam SR, et al. Catheter Cardiovasc Interv. 2001;52:393398
3. Brosh D, Assali A, Vaknin-Assa H, et al. Int J Cardiovasc Interv. 2005;7(4):183187
The ACIST | CVi Contrast Delivery System | 5
Simplifying Workflow
and Efficiency
The ACIST CVi system is designed and built to streamline
procedures and deliver faster case turnaround, while
minimizing the use of contrast.
Up to 20% reduction
in contrast dosage to the patient1
Up to 40% reduction
in contrast and cost1,2,3
Up to 31% reduction
in procedure and setup time4
Lower average contrast dose1
PER PATIENT IN MILLILITERS
Procedural time
Total contrast volume3
PER PATIENT IN MINUTES
PER PATIENT IN MILLILITERS
Setup & arterial4 Fluoroscopy3
242
Manual methods
ACIST CVi
202
Manual methods
230
11
163
112
Lower
20%
ACIST CVi
ACIST CVi
206
140
17%
Manual methods
16
10%
31%
31%
Saved
Saved
Saved
100
39%
Lower
Diagnostic
Diagnostic & PCI
Diagnostic
4.7
25%
Saved
Saved
Diagnostic & PCI
6.3
Diagnostic & PCI
Diagnostic
1. Anne G, Gruberg L, Huber A, et al. J Invasive Cardiol. 2004;16(7):360362
2. Call J, Sacrinty M, Applegate R, et al. J Invasive Cardiol. 2006;18(10):469474
3. Brosh D, Assali A, Vaknin-Assa H, et al. Int J Cardiovasc Interv. 2005;7(4):183187
4. Lehmann C, Hotaling M. J Invasive Cardiol. 2005;17(2):118121
6 | The ACIST | CVi Contrast Delivery System
The ACIST | CVi Contrast Delivery System | 7