Product datasheet
TM221CE24R
Characteristics
controller M221 24 IO relay Ethernet
Main
Modicon M221
Product or component type
Logic controller
[Us] rated supply voltage
100...240 V AC
Discrete input number
14 discrete input conforming to IEC 61131-2 Type
1
Analogue input number
2 at input range: 0...10 V
Discrete output type
Relay normally open
Discrete output number
10 relay
Discrete output voltage
5...125 V DC
5...250 V AC
Discrete output current
2A
Theinformationprovidedinthisdocumentationcontainsgeneraldescriptionsand/ortechnicalcharacteristicsoftheperformanceoftheproductscontainedherein.
Thisdocumentationisnotintendedasasubstituteforandisnottobeusedfordeterminingsuitabilityorreliabilityoftheseproductsforspecificuserapplications.
Itisthedutyofanysuchuserorintegratortoperformtheappropriateandcompleteriskanalysis,evaluationandtestingoftheproductswithrespecttotherelevantspecificapplicationorusethereof.
NeitherSchneiderElectricIndustriesSASnoranyofitsaffiliatesorsubsidiariesshallberesponsibleorliableformisuseoftheinformationcontainedherein.
Range of product
Complementary
Discrete I/O number
24
Number of I/O expansion module
<= 7 for transistor output
<= 7 for relay output
Supply voltage limits
85...264 V
Network frequency
50/60 Hz
Inrush current
<= 40 A
Power consumption in VA
<= 58 VA at 100...240 V with max number of I/O expansion module
<= 35 VA at 100...240 V without I/O expansion module
Power supply output current
0.52 A at 5 V for expansion bus
0.16 A at 24 V for expansion bus
Discrete input logic
Sink or source (positive/negative)
Discrete input voltage
24 V
Discrete input voltage type
DC
Analogue input resolution
10 bits
LSB value
10 mV
Conversion time
1 ms per channel + 1 controller cycle time for analog input
Permitted overload on inputs
+/- 30 V DC for analog input with 5 min maximum
+/- 13 V DC for analog input permanent
Voltage state1 guaranteed
>= 15 V for input
Current state 1 guaranteed
>= 2.6 mA for fast input
>= 4.2 mA for discrete input
Voltage state 0 guaranteed
<= 5 V for input
Current state 0 guaranteed
<= 1.3 mA for discrete input
<= 0.6 mA for fast input
Discrete input current
7 mA for discrete input
5 mA for fast input
Input impedance
4.9 kOhm for fast input
3.4 kOhm for discrete input
100 kOhm for analog input
Response time
10 ms turn-on operation for output
35 s turn-off operation for input; I2...I5 terminal
35 s turn-off operation for input; I2...I5 terminal
10 ms turn-off operation for output
5 s turn-on operation for fast input; I0, I1, I6, I7 terminal
35 s turn-on operation for input; other terminals terminal
5 s turn-off operation for fast input; I0, I1, I6, I7 terminal
100 s turn-off operation for input; other terminals terminal
Configurable filtering time
0 ms for input
12 ms for input
3 ms for input
1/9
Output voltage limits
125 V DC
277 V AC
Current per output common
4 A at COM 2 termnal
4 A at COM 2 termnal
7 A at COM 0 termnal
7 A at COM 1 termnal
Absolute accuracy error
+/- 1 % of full scale for analog input
Electrical durability
Inductive AC-15, (cos phi = 0.35) 240 V / 120 VA : 100000 cycles
Resistive DC-12, 24 V / 48 W : 100000 cycles
Resistive AC-12, 120 V / 240 VA : 100000 cycles
Inductive AC-15, (cos phi = 0.35) 240 V / 36 VA : 300000 cycles
Resistive AC-12, 120 V / 80 VA : 300000 cycles
Inductive (L/R = 7 ms) DC-13, 24 V / 24 W : 100000 cycles
Resistive DC-12, 24 V / 16 W : 300000 cycles
Inductive (L/R = 7 ms) DC-13, 24 V / 7.2 W : 300000 cycles
Inductive AC-14, (cos phi = 0.7) 240 V / 240 VA : 100000 cycles
Inductive AC-15, (cos phi = 0.35) 120 V / 60 VA : 100000 cycles
Inductive AC-14, (cos phi = 0.7) 240 V / 72 VA : 300000 cycles
Inductive AC-15, (cos phi = 0.35) 120 V / 18 VA : 300000 cycles
Resistive AC-12, 240 V / 480 VA : 100000 cycles
Inductive AC-14, (cos phi = 0.7) 120 V / 120 VA : 100000 cycles
Resistive AC-12, 240 V / 160 VA : 300000 cycles
Inductive AC-14, (cos phi = 0.7) 120 V / 36 VA : 300000 cycles
Switching frequency
20 switching operations/minute with maximum load
Mechanical durability
>= 20000000 cycles for relay output
Minimum load
1 mA at 5 V DC for relay output
Protection type
Without protection at 5 A
Reset time
1s
Memory capacity
256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up
256 kB built-in flash memory for backup of application and data
Data storage equipment
2 GB SD card optional
Battery type
BR2032 lithium non-rechargeable, battery life: 4 yr
Backup time
1 year at 25 C by interruption of power supply
Execution time for 1 KInstruction
0.3 ms for event and periodic task
Execution time per instruction
0.2 s Boolean
Exct time for event task
60 s response time
Maximum size of object areas
512 %M memory bits
8000 %MW memory words
512 %KW constant words
255 %TM timers
255 %C counters
Realtime clock
With
Clock drift
<= 30 s/month at 25 C
Regulation loop
Adjustable PID regulator up to 14 simultaneous loops
Counting input number
4 fast input (HSC mode) (counting frequency: 100 kHz), counting capacity: 32 bits
Control signal type
A/B
Pulse/direction
Single phase
Integrated connection type
USB port with connector mini B USB 2.0
Ethernet with connector RJ45
Non isolated serial link "serial 1" with connector RJ45 and interface RS232/RS485
Supply
Serial serial link supply at 5 V 200 mA
Transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication
protocol: RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m - communication
protocol: RS232
480 Mbit/s - communication protocol: USB
Communication port protocol
USB port : USB protocol - SoMachine-Network
Non isolated serial link : Modbus protocol master/slave - RTU/ASCII or SoMachineNetwork
: Ethernet protocol
Port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
Communication service
DHCP client
Ethernet/IP adapter
Modbus TCP server
2/9
Modbus TCP client
Modbus TCP slave device
Local signalling
1 LED red for module error (ERR)
1 LED green for PWR
1 LED green for RUN
1 LED green for SD card access (SD)
1 LED red for BAT
1 LED per channel green for I/O state
1 LED green for SL
Ethernet network activity green for ACT
Ethernet network link yellow for Link (Link Status)
Electrical connection
Mini B USB 2.0 connector for a programming terminal
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply
Connector, 4 terminal(s) for analogue inputs
Removable screw terminal block for inputs
Removable screw terminal block for outputs
Cable length
<= 10 m shielded cable for fast input
<= 10 m shielded cable for fast input
<= 30 m unshielded cable for output
<= 30 m unshielded cable for digital input
<= 1 m unshielded cable for analog input
Insulation
2300 V AC between output and internal logic
Non-insulated between analogue inputs
500 V AC between input and internal logic
Non-insulated between analogue input and internal logic
1500 V AC between supply and ground
500 V AC between sensor power supply and ground
500 V AC between input and ground
1500 V AC between output and ground
2300 V AC between supply and internal logic
500 V AC between sensor power supply and internal logic
500 V AC between Ethernet terminal and internal logic
2300 V AC between supply and sensor power supply
Marking
CE
Sensor power supply
DC at 250 mA supplied by the controller
Mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
Height
70 mm
Depth
70 mm
Width
110 mm
Product weight
0.395 kg
Environment
standards
EN/IEC 60664-1
EN/IEC 61131-2
EN/IEC 61010-2-201
product certifications
CSA
CULus
LR
IACS E10
RCM
EAC
DNV-GL
environmental characteristic
Ordinary and hazardous location
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m ( 80 MHz...1 GHz) conforming to EN/IEC 61000-4-3
3 V/m ( 1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
1 V/m ( 2...2.7 GHz) conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m at 50...60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients
2 kV for power lines conforming to EN/IEC 61000-4-4
2 kV for relay output conforming to EN/IEC 61000-4-4
1 kV for Ethernet line conforming to EN/IEC 61000-4-4
1 kV for serial link conforming to EN/IEC 61000-4-4
1 kV for I/O conforming to EN/IEC 61000-4-4
surge withstand
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for power lines (AC) in common mode conforming to EN/IEC 61000-4-5
2 kV for relay output in common mode conforming to EN/IEC 61000-4-5
1 kV for I/O in common mode conforming to EN/IEC 61000-4-5
3/9
1 kV for shielded cable in common mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for power lines (AC) in differential mode conforming to EN/IEC 61000-4-5
1 kV for relay output in differential mode conforming to EN/IEC 61000-4-5
0.5 kV for power lines (DC) in common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances, induced by radio 10 Vrms (0.15...80 MHz) conforming to EN/IEC 61000-4-6
frequency fields
3 Vrms (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
10 Vrms (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to
Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.15...0.5 MHz :
79 dBV/m QP/66 dBV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines (AC), 0.5...300 MHz :
73 dBV/m QP/60 dBV/m AV
Conducted emissions conforming to EN/IEC 55011 power lines, 10...150 kHz :
120...69 dBV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 150 kHz...1.5 MHz :
79...63 dBV/m QP
Conducted emissions conforming to EN/IEC 55011 power lines, 1.5...30 MHz : 63
dBV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 30...230 MHz : 40
dBV/m QP
Radiated emissions conforming to EN/IEC 55011 class A 10 m, 200 MHz...1 GHz : 47
dBV/m QP
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 C for horizontal installation
-10...35 C for vertical installation
ambient air temperature for storage
-25...70 C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20 with protective cover in place
pollution degree
<= 2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
3.5 mm (vibration frequency: 5...8.4 Hz) on symmetrical rail
1 gn (vibration frequency: 8.4...150 Hz) on symmetrical rail
3.5 mm (vibration frequency: 5...8.4 Hz) on panel mounting
1 gn (vibration frequency: 8.4...150 Hz) on panel mounting
shock resistance
98 m/s (test wave duration:11 ms)
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS (date code: YYWW)
Compliant - since 1415 - Schneider Electric declaration of conformity
REACh
Reference contains SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Available
Dimensions
Mounting on a Rail
4/9
Direct Mounting on a Panel Surface
(1)
Install a mounting strip
Mounting Hole Layout
Mounting
Correct Mounting Position
Acceptable Mounting Position
Incorrect Mounting Position
5/9
Clearance
Digital Inputs
Wiring Diagram (Positive Logic)
(*)
Type T fuse
Wiring Diagram (Negative Logic)
(*)
Type T fuse
Connection of the Fast Inputs
I0, I1, I6, I7
Relay Outputs
Negative Logic (Sink)
6/9
(*)
Type T fuse
(1)
The COM0, COM1 and COM2 terminals are not connected internally.
(2)
To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling
diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load
Sink wiring (negative logic)
Positive Logic (Source)
(*)
Type T fuse
(1)
The COM0, COM1 and COM2 terminals are not connected internally.
(2)
To improve the life time of the contacts, and to protect from potential inductive load damage, you must connect a free wheeling
diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load
Source wiring (positive logic)
Analog Inputs
The (-) poles are connected internally.
Pin
Wire Color
0V
Black
AN1
Red
0V
Black
AN0
Red
Ethernet Connection
Pin N Signal
1
TD+
7/9
TD-
RD+
RD-
USB Mini-B Connection
SL1 Connection
SL1
N
RS 232
RS 485
RxD
N.C.
TxD
N.C.
RTS
N.C.
N.C.
D1
N.C.
D0
CTS
N.C.
N.C*.
5 Vdc
Common Common
N.C.: not connected
* : 5 Vdc delivered by the controller. Do not connect.
8/9
Derating Curves
Embedded Digital Inputs (No Cartridge)
X:
Ambient temperature
Y:
Input simultaneous ON ratio
Embedded Digital Inputs (with Cartridge)
X:
Ambient temperature
Y:
Input simultaneous ON ratio
9/9