Errores KM 5050
Errores KM 5050
                                                                                 Remarks
  Code                      Contents
                                                          Causes           Check procedures/corrective measures
 C0030    Fax control PWB system problem             Defective fax con-   Replace the fax control PWB and verify the
          (optional fax)                             trol PWB.            operation.
          Processing with the fax software was
          disabled due to a hardware or software
          problem.
 C0060    Main PWB type mismatch error               Defective PWB.       Contact the Service Administrative Division.
 C0070    Fax control PWB incompatibility            FAX and the          Use the FAX control PWB that is designed
          detection problem (optional fax)           machine are not      for use with the machine.
          Fax software is not compatible with main   compatible.
          software.
 C0130    Backup memory (EEPROM) device              Defective main       Replace the main PWB and check for cor-
          problem (Main PWB)                         PWB.                 rect operation.
          Reading from or writing to EEPROM
                                                     Device damage of     Contact the Service Administrative Division.
          cannot be performed.
                                                     EEPROM.
 C0140    Backup memory (EEPROM) data        Data damage of               Contact the Service Administrative Division.
          problem (Main PWB)                 EEPROM.
          Reading data from EEPROM is abnor-
          mal.
 C0150    Backup memory device problem               Defective engine     Replace the engine PWB and check for cor-
          (Engine PWB)                               PWB.                 rect operation.
          Reading from or writing to EEPROM
                                                     Device damage of     Contact the Service Administrative Division.
          cannot be performed.
                                                     EEPROM.
 C0160    Backup memory data problem                 Problem with the     Run maintenance item U022 to initialize the
          (Engine PWB)                               backup memory        backup memory data.
          Reading data from EEPROM is abnor-         data.
          mal.
                                                     Defective engine     If the C0160 is displayed after initializing the
          Read and write data does not match five
                                                     PWB.                 backup memory, replace the engine PWB
          times continuously.
                                                                          and check for correct operation.
 C0170    Copy counts problem                        Data damage of       Contact the Service Administrative Division.
          A checksum error is detected in the main   EEPROM.
          and engine backup memories for the
                                                     Defective PWB.       Replace the main PWB or engine PWB and
          copy counters.
                                                                          check for correct operation.
 C0180    Machine number mismatch error              Data damage of       Contact the Service Administrative Division.
          Machine number of main PWB and             EEPROM.
          engine PWB does not match.
 C0600    DIMM installed incorrectly                 DIMM installed       Check if the DIMM is inserted into the socket
          DIMM is not installed correctly.           incorrectly.         on the main PWB correctly.
 C0610    DIMM problem                               Defective main       Replace the main PWB and check for cor-
          The DIMM on the main PWB does not          PWB.                 rect operation.
          operate correctly.
                                                     Defective DIMM.      Replace the DIMM and check for correct
                                                                          operation.
                                                                                                                    1-4-23
2GN/2GP/2GR
                                                                                   Remarks
  Code                   Contents
                                                           Causes            Check procedures/corrective measures
 C0630   DMA problem                                  Defective main        Replace the main PWB and check for cor-
         DMA transmission of compressed,              PWB.                  rect operation.
         decompressed, rotated, relocated or
         blanked-out image data does not com-
         plete within the specified period of time.
 C0640   Hard disk drive problem                      Poor contact in the   Check the connection of connector YC49 on
         The hard disk cannot be accessed.            connector termi-      the main PWB and the connector on the
                                                      nals.                 hard disk. Repair or replace if necessary.
                                                      Defective hard        Run U024 (HDD formatting) without turning
                                                      disk.                 the power off to initialize the hard disk.
                                                                            Replace the hard disk drive and check for
                                                                            correct operation if the problem is still
                                                                            detected after initialization.
                                                      Defective main        Replace the main PWB and check for cor-
                                                      PWB.                  rect operation.
 C0700   CF error for backup                          CF installed incor-   Install CF correctly.
         Optional data backup kit (CF) is not suit-   rectly.
         able as backup.
                                                      Defective CF.         Install normal CF.
 C0800   Image processing problem                     Defective main        Replace the main PWB and check for cor-
         JAM05 is detected twice.                     PWB.                  rect operation.
 C0830   Flash ROM program area checksum              Defective fax con-    Replace the fax control PWB and check for
         error (optional fax)                         trol PWB.             correct operation.
         A checksum error occurred with the pro-
         gram in the Flash ROM on the fax con-
         trol PWB.
 C0870   Fax control PWB to main PWB high             Poor contact in the   Check the connection of connector YC1 on
         capacity data transfer problem               connector termi-      the fax control PWB and YC4 on the inter-
         (optional fax)                               nals.                 face PWB, connection of connector YC30
         High-capacity data transfer between the                            on the main PWB and YC6 on the interface
         fax control PWB and the main PWB was                               PWB and the continuity across the connec-
         not normally performed even if the data                            tor terminals. Repair or replace if necessary.
         transfer was retried the specified times.
                                                      Defective fax con-    Replace the fax control PWB or main PWB
                                                      trol PWB or main      and check for correct operation.
                                                      PWB.
 C0880   Fax control PWB program archive              Defective fax con-    Replace the fax control PWB and check for
         problem (optional fax)                       trol PWB.             correct operation.
         When power is turned on, the com-
         pressed program in the Flash ROM on
         the fax control PWB was not success-
         fully decompressed.
 C0920   Fax file system error (optional fax)         Defective fax con-    Replace the fax control PWB and verify the
         The backup data is not retained for file     trol PWB.             operation.
         system abnormality of flash memory of
         the fax control PWB.
1-4-24
                                                                                                           2GN/2GP/2GR
                                                                                  Remarks
Code                    Contents
                                                          Causes            Check procedures/corrective measures
C1010   Upper lift motor error                      Poor contact in the    Check the connection of connector of upper
        When cassette 1 is inserted, upper lift     connector termi-       lift motor and the connector YC13 on the
        limit switch does not turn on within 12 s   nals.                  engine PWB, and the continuity across the
        of upper lift motor turning on.                                    connector terminals. Repair or replace if
                                                                           necessary.
                                                    Broken gears or        Replace upper lift motor.
                                                    couplings of upper
                                                    lift motor.
                                                    Defective upper lift   Check for continuity across the coil. If none,
                                                    motor.                 replace upper lift motor.
                                                    Defective upper lift   Check if YC13-B9 on the engine PWB goes
                                                    limit switch.          low when upper lift limit switch is turned off.
                                                                           If not, replace upper lift limit switch.
                                                    Poor contact in the    Check the connection of connector of upper
                                                    connector termi-       lift limit switch and the connector YC13 on
                                                    nals.                  the engine PWB, and the continuity across
                                                                           the connector terminals. Repair or replace if
                                                                           necessary.
                                                    Defective engine       Replace the engine PWB and check for cor-
                                                    PWB.                   rect operation.
C1020   Lower lift motor error                      Poor contact in the    Check the connection of connector of lower
        When cassette 2 is inserted, lower lift     connector termi-       lift motor and the connector YC13 on the
        limit switch does not turn on within 12 s   nals.                  engine PWB, and the continuity across the
        of lower lift motor turning on.                                    connector terminals. Repair or replace if
                                                                           necessary.
                                                    Broken gears or        Replace lower lift motor.
                                                    couplings of lower
                                                    lift motor.
                                                    Defective lower lift   Check for continuity across the coil. If none,
                                                    motor.                 replace lower lift motor.
                                                    Defective lower lift   Check if YC13-B15 on the engine PWB
                                                    limit switch.          goes low when lower lift limit switch is turned
                                                                           off. If not, replace lower lift limit switch.
                                                    Poor contact in the    Check the connection of connector of lower
                                                    connector termi-       lift limit switch and the connector YC13 on
                                                    nals.                  the engine PWB, and the continuity across
                                                                           the connector terminals. Repair or replace if
                                                                           necessary.
                                                    Defective engine       Replace the engine PWB and check for cor-
                                                    PWB.                   rect operation.
                                                                                                                    1-4-25
2GN/2GP/2GR
                                                                                      Remarks
  Code                   Contents
                                                             Causes             Check procedures/corrective measures
 C1030   Paper feeder lift motor 1 error               Poor contact in the     Check the connection of connector on the
         (optional paper feeder)                       connector termi-        engine PWB and the connector on the paper
         When optional cassette 3 is inserted,         nals.                   feeder main PWB, and the continuity across
         paper feeder lift switch 1 does not turn                              the connector terminals. Repair or replace if
         on within 12 s of paper feeder lift motor 1                           necessary.
         turning on.
                                                       Broken gears or         Replace paper feeder lift motor 1.
                                                       couplings of paper
                                                       feeder lift motor 1.
                                                       Defective paper         Check for continuity across the coil. If none,
                                                       feeder lift motor 1.    replace paper feeder lift motor 1.
                                                       Defective paper         Check if YC1-5 on the paper feeder main
                                                       feeder lift switch 1.   PWB goes low when paper feeder lift switch
                                                                               1 is turned off. If not, replace paper feeder lift
                                                                               switch 1.
 C1040   Paper feeder lift motor 2 error               Poor contact in the     Check the connection of connector on the
         (optional paper feeder)                       connector termi-        engine PWB and the connector on the paper
         When optional cassette 4 is inserted,         nals.                   feeder main PWB, and the continuity across
         paper feeder lift switch 2 does not turn                              the connector terminals. Repair or replace if
         on within 12 s of paper feeder lift motor 2                           necessary.
         turning on.
                                                       Broken gears or         Replace paper feeder lift motor 2.
                                                       couplings of paper
                                                       feeder lift motor 2.
                                                       Defective paper         Check for continuity across the coil. If none,
                                                       feeder lift motor 2.    replace paper feeder lift motor 2.
                                                       Defective paper         Check if YC1-7 on the paper feeder main
                                                       feeder lift switch 2.   PWB goes low when paper feeder lift switch
                                                                               2 is turned off. If not, replace paper feeder lift
                                                                               switch 2.
 C1100   Paper feeder lift motor 1 error               Poor contact in the     Check the connection of connector on the
         (optional 3000-sheet paper feeder)            connector termi-        engine PWB and the connector on the paper
         A motor over-current signal is detected       nals.                   feeder main PWB, and the continuity across
         continuously for 1 s or longer.                                       the connector terminals. Repair or replace if
                                                                               necessary.
                                                       Paper feeder lift       Check the gears and remedy if necessary.
                                                       motor 1 does not
                                                       rotate correctly (the
                                                       motor is over-
                                                       loaded).
 C1110   Paper feeder lift motor 2 error               Poor contact in the     Check the connection of connector on the
         (optional 3000-sheet paper feeder)            connector termi-        engine PWB and the connector on the paper
         A motor over-current signal is detected       nals.                   feeder main PWB, and the continuity across
         continuously for 1 s or longer.                                       the connector terminals. Repair or replace if
                                                                               necessary.
                                                       Paper feeder lift       Check the gears and remedy if necessary.
                                                       motor 2 does not
                                                       rotate correctly (the
                                                       motor is over-
                                                       loaded).
1-4-26
                                                                                                                2GN/2GP/2GR
                                                                                     Remarks
Code                   Contents
                                                          Causes               Check procedures/corrective measures
C1120   Paper feeder left lift position problem     Poor contact in the       Check the connection of connector on the
        (optional 3000-sheet paper feeder)          connector termi-          engine PWB and the connector on the paper
        Paper feeder switch 2 does not turn on      nals.                     feeder main PWB, and the continuity across
        within 30 s of paper feeder lift motor 1                              the connector terminals. Repair or replace if
        turning on.                                                           necessary.
                                                    Defective paper           Check if YC5-7 on the paper feeder main
                                                    feeder lift switch 2.     PWB goes low when paper feeder lift switch
                                                                              2 is turned off. If not, replace paper feeder lift
                                                                              switch 2.
                                                    Defective paper           Check for continuity across the coil. If none,
                                                    feeder lift motor 1.      replace paper feeder lift motor 1.
                                                    The paper feeder          Check the gears and belts, and remedy if
                                                    left lift does not rise   necessary.
                                                    properly.
C1130   Paper feeder right lift position prob-      Poor contact in the       Check the connection of connector on the
        lem (optional 3000-sheet paper              connector termi-          engine PWB and the connector on the paper
        feeder)                                     nals.                     feeder main PWB, and the continuity across
        Paper feeder switch 1 does not turn on                                the connector terminals. Repair or replace if
        within 30 s of paper feeder lift motor 2                              necessary.
        turning on.
                                                    Defective paper           Check if YC5-4 on the paper feeder main
                                                    feeder lift switch 1.     PWB goes low when paper feeder lift switch
                                                                              1 is turned off. If not, replace paper feeder lift
                                                                              switch 1.
                                                    Defective paper           Check for continuity across the coil. If none,
                                                    feeder lift motor 2.      replace paper feeder lift motor 2.
                                                    The paper feeder          Check the gears and belts, and remedy if
                                                    right lift does not       necessary.
                                                    rise properly.
C1800   Paper feeder unit communication             Poor contact in the       Check the connection of connector on the
        problem (optional paper feeder/3000-        connector termi-          engine PWB and the connector on the paper
        sheet paper feeder)                         nals.                     feeder main PWB, and the continuity across
        No communication: there is no reply                                   the connector terminals. Repair or replace if
        after 5 retries.                                                      necessary.
        Abnormal communication: a communica-
                                                    Defective engine          Replace the engine PWB and check for cor-
        tion error (parity or checksum error) is
                                                    PWB.                      rect operation.
        detected five times in succession.
                                                    Defective paper           Replace the paper feeder main PWB and
                                                    feeder main PWB.          check for correct operation.
C1900   Paper feeder EEPROM error (optional         Poor contact in the       Check the connection of connector on the
        paper feeder)                               connector termi-          engine PWB and the connector on the paper
        When writing the data, the write data and   nals.                     feeder main PWB, and the continuity across
        the read data is not continuously in                                  the connector terminals. Repair or replace if
        agreement three times.                                                necessary.
                                                    Defective engine          Replace the engine PWB and check for cor-
                                                    PWB.                      rect operation.
                                                    Defective paper           Replace the paper feeder with another unit
                                                    feeder.                   and check the operation. If the operation is
                                                                              normal, replace or repair optional paper
                                                                              feeder.
                                                                                                                          1-4-27
2GN/2GP/2GR
                                                                               Remarks
  Code                  Contents
                                                        Causes            Check procedures/corrective measures
 C2000   Drive motor problem                       Poor contact in the   Check the connection of connector YC11 on
         Stable OFF is detected for 1 s continu-   connector termi-      the engine PWB and the connector on the
         ously after drive motor stability.        nals.                 drive motor, and the continuity across the
                                                                         connector terminals. Repair or replace if
                                                                         necessary.
                                                   Defective drive       Check if the rollers and gears rotate
                                                   transmission sys-     smoothly. If not, grease the bushings and
                                                   tem.                  gears. Check for broken gears and replace if
                                                                         any.
                                                   Defective engine      Replace the engine PWB and check for cor-
                                                   PWB.                  rect operation.
                                                   Defective drive       Replace the drive motor.
                                                   motor.
 C2250   Main charger cleaning motor error         Poor contact in the   Check the connection of connector YC9 on
         A locking error has been detected three   connector termi-      the engine PWB and the connector on the
         times in a row during a reciprocating     nals.                 main charger cleaning motor, and the conti-
         cleaning motion.                                                nuity across the connector terminals. Repair
                                                                         or replace if necessary.
                                                   Defective drive       Check if the rollers and gears rotate
                                                   transmission sys-     smoothly. If not, grease the bushings and
                                                   tem.                  gears. Check for broken gears and replace if
                                                                         any.
                                                   Defective engine      Replace the engine PWB and check for cor-
                                                   PWB.                  rect operation.
                                                   Defective main        Replace the main charger cleaning motor.
                                                   charger cleaning
                                                   motor.
 C2500   Paper feed motor error                    Poor contact in the   Check the connection of connector YC11 on
         Stable OFF is detected for 1 s continu-   connector termi-      the engine PWB and the connector on the
         ously after paper feed motor stability.   nals.                 paper feed motor, and the continuity across
                                                                         the connector terminals. Repair or replace if
                                                                         necessary.
                                                   Defective drive       Check if the rollers and gears rotate
                                                   transmission sys-     smoothly. If not, grease the bushings and
                                                   tem.                  gears. Check for broken gears and replace if
                                                                         any.
                                                   Defective engine      Replace the engine PWB and check for cor-
                                                   PWB.                  rect operation.
                                                   Defective paper       Replace the paper feed motor.
                                                   feed motor.
1-4-28
                                                                                                          2GN/2GP/2GR
                                                                                 Remarks
Code                    Contents
                                                          Causes           Check procedures/corrective measures
C4010   Polygon motor steady-state problem          Poor contact in the   Check the connection of connector YC8 on
        The polygon motor rotation is not stable    connector termi-      the engine PWB and laser scanner unit, and
        for 20 s after the polygon motor rotation   nals.                 the continuity across the connector termi-
        has been stabilized.                                              nals. Repair or replace if necessary.
                                                    Defective polygon     Replace the laser scanner unit.
                                                    motor.
                                                    Defective engine      Replace the engine PWB and check for cor-
                                                    PWB.                  rect operation.
C4200   BD steady-state problem                     Poor contact in the   Check the connection of connector YC8 on
        ASIC detects a BD error A for 2 s after     connector termi-      the engine PWB and laser scanner unit, and
        the polygon motor rotation has been sta-    nals.                 the continuity across the connector termi-
        bilized.                                                          nals. Repair or replace if necessary.
                                                    Defective laser       Replace the laser scanner unit.
                                                    scanner unit.
                                                    Defective engine      Replace the engine PWB and check for cor-
                                                    PWB.                  rect operation.
C5300   Broken cleaning lamp wire                   Defective cleaning    Replace the cleaning lamp.
        While the cleaning lamp is on, the bro-     lamp.
        ken cleaning lamp wire detection signal
                                                    Defective engine      Replace the engine PWB and check for cor-
        is detected for 2 s continuously.
                                                    PWB.                  rect operation.
C6000   Fuser heater break                          Defective fuser       Replace the fuser heater M or S.
        Fuser thermistor 1 is detected 40C/        heater M or S.
        104F below with 10 s continuously dur-
                                                    Installation defec-   Check the mounting state of the fuser ther-
        ing warm-up and ready in.
                                                    tiveness on fuser     mistor 1. If any problem is found, repair it.
                                                    thermistor 1.
                                                    Defective fuser       Replace the fuser thermostat.
                                                    thermostat.
                                                    Defective PWB.        Replace the power source PWB or engine
                                                                          PWB and check for correct operation.
C6020   Abnormally high fuser thermistor            Installation defec-   Check the mounting state of the fuser ther-
        temperature                                 tiveness on fuser     mistor 1 or 2. If any problem is found, repair
        Fuser thermistor 1 or 2 is detected         thermistor 1 or 2.    it.
        230C/446F or more for 40 ms.
                                                    Defective fuser       Replace the fuser thermistor 1 or 2.
                                                    thermistor 1 or 2.
                                                    Defective engine      Replace the engine PWB and check for cor-
                                                    PWB.                  rect operation.
C6030   Fuser thermistor break error                Installation defec-   Check the mounting state of the fuser ther-
        The thermistor break signal is detected     tiveness on fuser     mistor 1 or 2. If any problem is found, repair
        continuously for 500 ms.                    thermistor 1 or 2.    it.
                                                    Defective fuser       Replace the fuser thermistor 1 or 2.
                                                    thermistor 1 or 2.
                                                    Defective engine      Replace the engine PWB and check for cor-
                                                    PWB.                  rect operation.
                                                                                                                  1-4-31
2GN/2GP/2GR
                                                                                   Remarks
  Code                   Contents
                                                           Causes            Check procedures/corrective measures
 C3210   CIS lamp problem                             Poor contact in the   Check the connection of connector on the
         After the reading starting, when input       connector termi-      main PWB and the connector on the DP
         value at the time of CIS illumination does   nals.                 main PWB, and the continuity across the
         not exceed the threshold value between                             connector terminals. Repair or replace if
         5 s.                                                               necessary.
                                                      Defective DP main     Replace the DP main PWB and check for
                                                      PWB.                  correct operation.
                                                      Defective DP          Replace the DP inverter PWB and check for
                                                      inverter PWB.         correct operation.
                                                      Defective CIS.        Replace the CIS and check for correct oper-
                                                                            ation.
 C3300   CCD AGC problem                              Poor contact in the   Check the connection of connector on the
         After AGC, correct input is not obtained     connector termi-      SHD PWB and the connector on the CCD
         at CCD.                                      nals.                 PWB, and the continuity across the connec-
                                                                            tor terminals. Repair or replace if necessary.
                                                      Defective exposure    Replace the exposure lamp or inverter
                                                      lamp.                 PWB.
                                                      Defective PWB.        Replace the SHD PWB or CCD PWB and
                                                                            check for correct operation.
 C3310   CIS AGC problem                              Defective DP main     Replace the DP main PWB and check for
         After AGC, correct input is not obtained     PWB.                  correct operation.
         at CIS.
                                                      CIS output prob-      Replace the CIS and check for correct oper-
                                                      lem.                  ation.
                                                      Defective DP          Replace the DP inverter PWB and check for
                                                      inverter PWB.         correct operation.
 C3500   Communication error between scan-            Poor contact in the   Check the connection of connector YC3 on
         ner and SHD                                  connector termi-      the scanner PWB and the connector YC4 on
         An error code is detected.                   nals.                 the SHD PWB, and the continuity across the
                                                                            connector terminals. Repair or replace if
                                                                            necessary.
                                                      Defective PWB.        Replace the scanner PWB or SHD PWB and
                                                                            check for correct operation.
 C3900   Backup memory read/write problem             Defective backup      Replace the scanner PWB and check for
         (scanner PWB)                                RAM or scanner        correct operation.
         Read and write data does not match.          PWB.
 C3910   Backup memory data problem (scan-            Problem with the      Run maintenance item U022 to initialize the
         ner PWB)                                     backup memory         backup memory data.
         Data in the specified area of the backup     data.
         memory does not match the specified
                                                      Defective scanner     If the C3910 is displayed after initializing the
         values.
                                                      PWB.                  backup memory, replace the scanner PWB
                                                                            and check for correct operation.
 C4000   Polygon motor synchronization prob-          Poor contact in the   Check the connection of connector YC8 on
         lem                                          connector termi-      the engine PWB and laser scanner unit, and
         The polygon motor does not reach the         nals.                 the continuity across the connector termi-
         stable speed within 20 s of the START                              nals. Repair or replace if necessary.
         signal turning on.
                                                      Defective polygon     Replace the laser scanner unit.
                                                      motor.
                                                      Defective engine      Replace the engine PWB and check for cor-
                                                      PWB.                  rect operation.
1-4-30
                                                                                                          2GN/2GP/2GR
                                                                                 Remarks
Code                    Contents
                                                         Causes            Check procedures/corrective measures
C2600   Paper feeder paper conveying motor          Poor contact in the   Check the connection of connector on the
        error (optional 3000-sheet paper            connector termi-      engine PWB and the connector on the paper
        feeder)                                     nals.                 feeder main PWB, and the continuity across
        The lock signal of the motor is detected                          the connector terminals. Repair or replace if
        avobe 450 ms.                                                     necessary.
        Paper feeder drive motor error
                                                    Paper feeder paper    Check the gears and remedy if necessary.
        (optional paper feeder)
                                                    conveying motor /
        The lock signal of the motor is detected
                                                    paper feeder drive
        avobe 500 ms.
                                                    motor does not
                                                    rotate correctly
                                                    (the motor is over-
                                                    loaded).
                                                    Defective PWB.        Replace the paper feeder main PWB or
                                                                          engine PWB and check for correct opera-
                                                                          tion.
                                                    Defective motor.      Replace the paper feeder paper conveying
                                                                          motor / paper feeder drive motor.
C3100   Scanner carriage problem                    Poor contact in the   Check the connection of connector YC4 on
        The home position is not correct when       connector termi-      the scanner PWB and the connector on the
        the power is turned on or at the start of   nals.                 scanner home position switch, and the conti-
        copying using the table.                                          nuity across the connector terminals. Repair
                                                                          or replace if necessary.
                                                    Defective scanner     Replace the scanner PWB and check for
                                                    PWB.                  correct operation.
                                                    Defective scanner     Replace the scanner home position switch.
                                                    home position
                                                    switch.
                                                    Defective scanner     Replace the scanner motor.
                                                    motor.
                                                    The mirror frame,     Check if the mirror flames and exposure
                                                    exposure lamp, or     lamp are on the rail. And check the scanner
                                                    scanner wire is       wire winds correctly.
                                                    defective.
C3200   Exposure lamp problem                      Poor contact in the    Check the connection of connector YC6 on
        After the reading starting, when input     connector termi-       the scanner PWB and the connector on the
        value at the time of exposure lamp illumi- nals.                  inverter PWB, and the continuity across the
        nation does not exceed the threshold                              connector terminals. Repair or replace if
        value between 5 s.                                                necessary.
                                                    Defective scanner     Replace the scanner PWB and check for
                                                    PWB.                  correct operation.
                                                    Defective CCD         Replace the CCD PWB and check for cor-
                                                    PWB.                  rect operation.
                                                    Defective exposure    Replace the exposure lamp or inverter
                                                    lamp or inverter      PWB.
                                                    PWB.
                                                    Incorrect shading     Adjust the position of the contact glass
                                                    position.             (shading plate). If the problem still occurs,
                                                                          replace the scanner home position switch.
                                                                                                                   1-4-29
2GN/2GP/2GR
                                                                                 Remarks
  Code                  Contents
                                                         Causes            Check procedures/corrective measures
 C6050   Abnormally low fuser thermistor 3         Defective fuser        Replace the fuser heater M or S.
         temperature                               heater M or S.
         Fuser thermistor 1 is detected 100C/
                                                   Installation defec-    Check the mounting state of the fuser ther-
         212F less than 1 s continuously during
                                                   tiveness on fuser      mistor 1. If any problem is found, repair it.
         copying.
                                                   thermistor 1.
                                                   Defective PWB.         Replace the power source PWB or engine
                                                                          PWB and check for correct operation.
 C6400   Zero-cross signal error                   Defective PWB.         Replace the engine PWB or power source
         While fuser heater ON/OFF control is                             PWB and check for correct operation.
         performed, the zero-cross signal is not
         input within 3 s.
 C6410   Fuser unit connector insertion prob-      Fuser unit connec-     Reinsert the fuser unit connector if neces-
         lem                                       tor inserted incor-    sary.
         Absence of the fuser unit is detected.    rectly.
                                                   Defective fuser unit   Replace the fuser unit.
                                                   connector.
 C6420   Fuser unit fuse cut problem             Poor contact in the      Check the connection of connector YC10 on
         The fuse in the fuser unit did not blow connector termi-         the engine PWB and the continuity across
         within three seconds.                   nals.                    the connector terminals. Repair or replace if
                                                                          necessary.
                                                   Fuser unit connec-     Reinsert the fuser unit connector if neces-
                                                   tor inserted incor-    sary.
                                                   rectly.
 C7300   Toner container problem                   Poor contact in the    Check the connection of connector YC9 on
         Toner level is not detected when toner    connector termi-       the engine PWB and the continuity across
         empty is detected.                        nals.                  the connector terminals. Repair or replace if
                                                                          necessary.
                                                   Defective toner        Replace the toner container sensor.
                                                   container sensor.
 C7400   Developing unit connector insertion       Developing unit        Reinsert the developing unit connector if
         problem                                   connector inserted     necessary.
         Absence of the developing unit is         incorrectly.
         detected.
                                                   Defective develop-     Replace the developing unit.
                                                   ing unit connector.
 C7410   Drum unit connector insertion prob-       Drum unit connec-      Reinsert the drum unit connector if neces-
         lem                                       tor inserted incor-    sary.
         Absence of the drum unit is detected.     rectly.
                                                   Defective drum unit    Replace the drum unit.
                                                   connector.
 C7800   Broken external thermistor wire           Poor contact in the    Check the connection of connector YC14 on
         The thermistor output value is 4.5 V or   connector termi-       the engine PWB and the continuity across
         more.                                     nals.                  the connector terminals. Repair or replace if
                                                                          necessary.
                                                   Defective humidity     Replace the humidity sensor.
                                                   sensor.
1-4-32
                                                                                                            2GN/2GP/2GR
                                                                                   Remarks
Code                    Contents
                                                           Causes             Check procedures/corrective measures
C7810   Short-circuited external thermistor           Poor contact in the    Check the connection of connector YC14 on
        The thermistor input value is 0.5 V or        connector termi-       the engine PWB and the continuity across
        less.                                         nals.                  the connector terminals. Repair or replace if
                                                                             necessary.
                                                      Defective humidity     Replace the humidity sensor.
                                                      sensor.
C7900   Drum EEPROM error                             Poor contact in the    Check the connection of connector on the
        Reading from or writing to EEPROM             connector termi-       engine PWB and the continuity across the
        cannot be performed.                          nals.                  connector terminals. Repair or replace if
                                                                             necessary.
                                                      Defective drum         Replace the drum unit.
                                                      unit.
C7910   Developing unit EEPROM error                  Poor contact in the    Check the connection of connector on the
        Reading from or writing to EEPROM             connector termi-       engine PWB and the continuity across the
        cannot be performed.                          nals.                  connector terminals. Repair or replace if
                                                                             necessary.
                                                      Defective develop-     Replace the developing unit.
                                                      ing unit.
C8020   Punch motor problem (optional 3000-           Poor contact in the    Check the connection of connector on the
        sheet document finisher)                      connector termi-       punch PWB and the continuity across the
        The LOCK signal of the punch motor is         nals.                  connector terminals. Repair or replace if
        detected for more than 500 ms while the                              necessary.
        punch motor is operating.
                                                      Defective punch        Replace the punch motor.
                                                      motor.
                                                      Defective PWB.         Replace the punch PWB or finisher main
                                                                             PWB and check for correct operation.
C8030   Tray upper limit detection problem            The tray upper limit   Reinsert the connector. Also check for conti-
        (optional document finisher)                  sensor/push paper      nuity within the connector cable. If none,
        When the tray elevation motor raises a        sensor/surface         remedy or replace the cable.
        tray, the ON status of the tray upper limit   view sensor con-
        sensor is detected.                           nector makes poor
                                                      contact.
                                                      Defective tray      Replace the sensor.
                                                      upper limit sensor/
                                                      push paper sensor/
                                                      surface view sen-
                                                      sor.
                                                      Defective finisher     Replace the finisher main PWB and check
                                                      main PWB.              for correct operation.
                                                                                                                    1-4-33
2GN/2GP/2GR
                                                                               Remarks
  Code                  Contents
                                                        Causes           Check procedures/corrective measures
 C8050   Paper conveying belt motor 1 prob-        Poor contact in the   Check the connection of connector YC2 on
         lem (optional 3000-sheet document         connector termi-      the internal tray PWB and the connector on
         finisher)                                 nals.                 paper conveying belt motor 1, and the conti-
         Paper conveying belt home position sen-                         nuity across the connector terminals. Repair
         sor 1 does not turn off within 1.5 s.                           or replace if necessary.
         Paper conveying belt home position sen-
                                                   Defective paper       Replace paper conveying belt home position
         sor 1 does not turn on within 2.5 s.
                                                   conveying belt        sensor 1.
         Jam 88 is indicated.
                                                   home position sen-
                                                   sor 1.
                                                   Defective paper       Replace paper conveying belt motor 1.
                                                   conveying belt
                                                   motor 1.
                                                   Defective PWB.        Replace the internal tray PWB or finisher
                                                                         main PWB and check for correct operation.
 C8060   Paper conveying belt motor 2 prob-        Poor contact in the   Check the connection of connector YC6 on
         lem (optional 3000-sheet document         connector termi-      the internal tray PWB and the connector on
         finisher)                                 nals.                 paper conveying belt motor 2, and the conti-
         Paper conveying belt home position sen-                         nuity across the connector terminals. Repair
         sor 2 does not turn off within 1.5 s.                           or replace if necessary.
         Paper conveying belt home position sen-
                                                   Defective paper       Replace paper conveying belt home position
         sor 2 does not turn on within 2.5 s.
                                                   conveying belt        sensor 2.
                                                   home position sen-
                                                   sor 2.
                                                   Defective paper       Replace paper conveying belt motor 2.
                                                   conveying belt
                                                   motor 2.
                                                   Defective PWB.        Replace the internal tray PWB or finisher
                                                                         main PWB and check for correct operation.
 C8070   Internal tray communication error         Poor contact in the   Check the connection of connector YC6 on
         (optional 3000-sheet document fin-        connector termi-      the finisher main PWB and the connector
         isher)                                    nals.                 YC1 on the internal tray PWB, and the conti-
         Communication with the internal tray is                         nuity across the connector terminals. Repair
         not possible although the connection is                         or replace if necessary.
         detected.
                                                   Defective PWB.        Replace the internal tray PWB or finisher
                                                                         main PWB and check for correct operation.
1-4-34
                                                                                                           2GN/2GP/2GR
                                                                                  Remarks
Code                    Contents
                                                           Causes            Check procedures/corrective measures
C8140   Main tray problem (optional 3000-            Poor contact in the    Check the connection of connector YC6 on
        sheet document finisher)                     connector termi-       the finisher main PWB and the connector on
        The main tray is not detected by the         nals.                  the main tray motor, and the continuity
        main tray top limit detection sensor or                             across the connector terminals. Repair or
        the main tray capacity detection sensor                             replace if necessary.
        within 20s since the tray has started
                                                     Defective main tray    Replace the main tray motor.
        ascending.
                                                     motor.
        The main tray upper limit detection sen-
        sor or the main tray load detection sen-     Defective main tray    Replace the sensor.
        sor is not detected to be turned off in 20   upper limit detec-
        seconds after the main tray has              tion sensor/main
        descended.                                   tray load detection
        The main tray low limit detection sensor     sensor/main tray
        is not detected to be turned on in 20 sec-   lower limit detec-
        onds after the main tray has descended.      tion sensor.
        During main tray ascent, the main tray
        upper limit detection sensor or the main     Defective finisher     Replace the finisher main PWB and check
        tray load detection sensor stays on for      main PWB.              for correct operation.
        more than 2 s.
        Tray elevation motor problem                 The tray elevation     Reinsert the connector. Also check for conti-
        (optional document finisher)                 motor connector        nuity within the connector cable. If none,
        When the tray elevation motor is driving,    makes poor con-        remedy or replace the cable.
        the ON status of the tray lower limit sen-   tact.
        sor or surface view sensor cannot be
                                                     The tray elevation     Replace the tray elevation motor.
        detected even if a specified time has
                                                     motor malfunc-
        elapsed.
                                                     tions.
                                                     The tray lower limit   Reinsert the connector. Also check for conti-
                                                     sensor/push paper      nuity within the connector cable. If none,
                                                     sensor/surface         remedy or replace the cable.
                                                     view sensor con-
                                                     nector makes poor
                                                     contact.
                                                     Defective tray      Replace the sensor.
                                                     lower limit sensor/
                                                     push paper sensor/
                                                     surface view sen-
                                                     sor.
                                                     Defective finisher     Replace the finisher main PWB and check
                                                     main PWB.              for correct operation.
                                                                                                                   1-4-35
2GN/2GP/2GR
                                                                                      Remarks
  Code                    Contents
                                                              Causes             Check procedures/corrective measures
 C8170   Side registration motor 1 problem               Poor contact in the    Check the connection of connector YC2 on
         (optional 3000-sheet document fin-              connector termi-       the internal tray PWB and the connector on
         isher)                                          nals.                  side registration motor 1, and the continuity
         When operation returned to a home                                      across the connector terminals. Repair or
         position is performed at the time of initial                           replace if necessary.
         operation and a home position is not
                                                         Defective side reg-    Replace side registration motor 1.
         detected even if 3 s passed.
                                                         istration motor 1.
         Jam 88 is indicated.
                                                         Defective PWB.         Replace the internal tray PWB or finisher
                                                                                main PWB and check for correct operation.
         Adjustment motor problem (optional              The adjustment         Reinsert the connector. Also check for conti-
         document finisher)                              motor connector        nuity within the connector cable. If none,
         When the adjustment motor is driving,           makes poor con-        remedy or replace the cable.
         the ON status of the adjustment home            tact.
         position sensor cannot be detected even
                                                         Defective adjust-      Replace adjustment motor.
         if a specified time has elapsed.
                                                         ment motor.
         When adjustment operation starts, the
         ON status of the adjustment home posi-          The adjustment         Reinsert the connector. Also check for conti-
         tion sensor is not detected.                    home position sen-     nuity within the connector cable. If none,
                                                         sor connector          remedy or replace the cable.
                                                         makes poor con-
                                                         tact.
                                                         Defective adjust-      Replace the adjustment home position sen-
                                                         ment home posi-        sor.
                                                         tion sensor.
                                                         Defective finisher     Replace the finisher main PWB and check
                                                         main PWB.              for correct operation.
         Finisher front side registration motor          The front side reg- Reinsert the connector. Also check for conti-
         problem (optional built-in finisher)            istration motor con- nuity within the connector cable. If none,
         When the front-side registration home-          nector makes poor remedy or replace the cable.
         position sensor is turned on during initial-    contact.
         ization, the sensor did not turn on while it
                                                         Defective front side   Replace front side registration motor.
         has moved by 106 pulses.
                                                         registration motor.
         When the front-side registration home-
         position sensor is turned off during initial-   The front side reg-    Reinsert the connector. Also check for conti-
         ization, the sensor did not turn on in          istration home         nuity within the connector cable. If none,
         three seconds.                                  position sensor        remedy or replace the cable.
                                                         connector makes
                                                         poor contact.
                                                         Defective front side   Replace the front side registration home
                                                         registration home      position sensor.
                                                         position sensor.
                                                         Defective finisher     Replace the finisher control PWB and check
                                                         control PWB.           for correct operation.
1-4-36
                                                                                                             2GN/2GP/2GR
                                                                                    Remarks
Code                     Contents
                                                              Causes           Check procedures/corrective measures
C8180   Side registration motor 2 problem               Poor contact in the   Check the connection of connector YC8 on
        (optional 3000-sheet document fin-              connector termi-      the internal tray PWB and the connector of
        isher)                                          nals.                 side registration motor 2, and the continuity
        When operation returned to a home                                     across the connector terminals. Repair or
        position is performed at the time of initial                          replace if necessary.
        operation and a home position is not
                                                        Defective side reg-   Replace side registration motor 2.
        detected even if 3 s passed.
                                                        istration motor 2.
        Jam 88 is indicated.
                                                        Defective PWB.        Replace the internal tray PWB or finisher
                                                                              main PWB and check for correct operation.
        Finisher rear side registration motor           The rear side reg-   Reinsert the connector. Also check for conti-
        problem (optional built-in finisher)            istration motor con- nuity within the connector cable. If none,
        When the rear-side registration home-           nector makes poor remedy or replace the cable.
        position sensor is turned on during initial-    contact.
        ization, the sensor did not turn on while it
                                                        Defective rear side   Replace rear side registration motor.
        has moved by 106 pulses.
                                                        registration motor.
        When the rear-side registration home-
        position sensor is turned off during initial-   The rear side reg-    Reinsert the connector. Also check for conti-
        ization, the sensor did not turn on in          istration home        nuity within the connector cable. If none,
        three seconds.                                  position sensor       remedy or replace the cable.
                                                        connector makes
                                                        poor contact.
                                                        Defective rear side   Replace the rear side registration home
                                                        registration home     position sensor.
                                                        position sensor.
                                                        Defective finisher    Replace the finisher control PWB and check
                                                        control PWB.          for correct operation.
C8190   Finisher trailing edge registration             The trailing edge     Reinsert the connector. Also check for conti-
        motor problem (optional built-in fin-           registration motor    nuity within the connector cable. If none,
        isher)                                          connector makes       remedy or replace the cable.
        When the trailing edge registration             poor contact.
        home-position sensor is turned on during
                                                        Defective trailing    Replace trailing edge registration motor.
        initialization, the sensor did not turn on
                                                        edge registration
        while it has moved by 106 pulses.
                                                        motor.
        When the trailing edge registration
        home-position sensor is turned off during       The trailing edge     Reinsert the connector. Also check for conti-
        initialization, the sensor did not turn on in   registration home     nuity within the connector cable. If none,
        three seconds.                                  position sensor       remedy or replace the cable.
                                                        connector makes
                                                        poor contact.
                                                        Defective trailing    Replace the trailing edge registration home
                                                        edge registration     position sensor.
                                                        home position sen-
                                                        sor.
                                                        Defective finisher    Replace the finisher control PWB and check
                                                        control PWB.          for correct operation.
                                                                                                                      1-4-37
2GN/2GP/2GR
                                                                                     Remarks
  Code                   Contents
                                                             Causes            Check procedures/corrective measures
 C8210   Stapler moving motor 1 error                   Poor contact in the   Check the connection of connector YC9 on
         (optional 3000-sheet document fin-             connector termi-      the finisher main PWB and the connector of
         isher)                                         nals.                 stapler moving motor 1, and the continuity
         When operation returned to a home                                    across the connector terminals. Repair or
         position is performed at the time of initial                         replace if necessary.
         operation and a home position is not
                                                        Defective stapler     Replace stapler moving motor 1.
         detected even if 1.5 s passed.
                                                        moving motor 1.
                                                        Defective finisher    Replace the finisher main PWB and check
                                                        main PWB.             for correct operation.
         Stapler problem (optional document             The stapler con-      Reinsert the connector. Also check for conti-
         finisher)                                      nector makes poor     nuity within the connector cable. If none,
         When the stapler motor is driving, the         contact.              remedy or replace the cable.
         ON status of the stapler home position
                                                        The stapler is        Remove the stapler cartridge, and check the
         sensor cannot be detected even if a
                                                        blocked with a sta-   cartridge and the stapling section of the sta-
         specified time has elapsed.
                                                        ple.                  pler.
                                                        The stapler is bro-   Replace the stapler and check for correct
                                                        ken.                  operation.
                                                        Defective finisher    Replace the finisher main PWB and check
                                                        main PWB.             for correct operation.
         Finisher stapler problem (optional             The stapler con-      Reinsert the connector. Also check for conti-
         built-in finisher)                             nector makes poor     nuity within the connector cable. If none,
         The stapler home position sensor does          contact.              remedy or replace the cable.
         not change state from nondetection to
                                                        The stapler is        Remove the stapler cartridge, and check the
         detection within 200 ms of the start of
                                                        blocked with a sta-   cartridge and the stapling section of the sta-
         stapler motor counterclockwise (forward)
                                                        ple.                  pler.
         rotation.
         During initialization, the stapler home        The stapler is bro-   Replace the front stapler and check for cor-
         position sensor does not change state          ken.                  rect operation.
         from non-detection to detection within
         600 ms of the start of stapler motor           Defective finisher    Replace the finisher control PWB and check
         clockwise (reverse) rotation.                  control PWB.          for correct operation.
 C8220   Stapler moving motor 2 error                   Poor contact in the   Check the connection of connector YC10 on
         (optional 3000-sheet document fin-             connector termi-      the finisher main PWB and the connector of
         isher)                                         nals.                 stapler moving motor 2, and the continuity
         When operation returned to a home                                    across the connector terminals. Repair or
         position is performed at the time of initial                         replace if necessary.
         operation and a home position is not
                                                        Defective stapler     Replace stapler moving motor 2.
         detected even if 3.5 s passed.
                                                        moving motor 2.
                                                        Defective finisher    Replace the finisher main PWB and check
                                                        main PWB.             for correct operation.
 C8230   Stapler motor problem (optional 3000- Poor contact in the            Check the connection of connector YC10 on
         sheet document finisher)              connector termi-               the finisher main PWB and the connector of
         Jam 82 is indicated.                  nals.                          stapler motor, and the continuity across the
                                                                              connector terminals. Repair or replace if
                                                                              necessary.
                                                        Defective stapler     Replace the stapler motor.
                                                        motor.
                                                        Defective finisher    Replace the finisher main PWB and check
                                                        main PWB.             for correct operation.
1-4-38
                                                                                                           2GN/2GP/2GR
                                                                                  Remarks
Code                   Contents
                                                          Causes             Check procedures/corrective measures
C8300   Centerfold unit communication error         Poor contact in the     Check the connection of connector YC22 on
        (optional centerfold unit of 3000-sheet     connector termi-        the finisher main PWB and the continuity
        document finisher)                          nals.                   across the connector terminals. Repair or
        Communication with the centerfold unit                              replace if necessary.
        is not possible although the connection
                                                    Defective center-       Replace the centerfold unit set switch.
        is detected.
                                                    fold unit set switch.
                                                    Defective finisher      Replace the finisher main PWB and check
                                                    main PWB.               for correct operation.
C8310   Centerfold side registration motor 1        Poor contact in the     Check the connection of connector YC6 on
        problem (optional centerfold unit of        connector termi-        the centerfold main PWB and the connector
        3000-sheet document finisher)               nals.                   of centerfold side registration motor 1, and
        The home position is not detected when                              the continuity across the connector termi-
        initial operation even if 1000 ms passed.                           nals. Repair or replace if necessary.
                                                    Defective center-       Replace centerfold side registration motor 1.
                                                    fold side registra-
                                                    tion motor 1.
                                                    Defective PWB.          Replace the centerfold main PWB or finisher
                                                                            main PWB and check for correct operation.
C8320   Centerfold paper conveying belt             Poor contact in the     Check the connection of connector YC6/
        motor problem (optional centerfold          connector termi-        YC7 on the centerfold main PWB and the
        unit of 3000-sheet document finisher)       nals.                   connector of centerfold paper conveying belt
        The home position is not detected when                              motor 1/2, and the continuity across the con-
        initial operation even if 2500 ms passed.                           nector terminals. Repair or replace if neces-
                                                                            sary.
                                                    Defective center-       Replace centerfold paper conveying belt
                                                    fold paper convey-      motor 1/2.
                                                    ing belt motor 1/2.
                                                    Defective PWB.          Replace the centerfold main PWB or finisher
                                                                            main PWB and check for correct operation.
C8330   Blade motor problem (optional cen-          Poor contact in the     Check the connection of connector YC8 on
        terfold unit of 3000-sheet document         connector termi-        the centerfold main PWB and the connector
        finisher)                                   nals.                   of the blade motor, and the continuity across
        The home position is not detected when                              the connector terminals. Repair or replace if
        initial operation even if 1500 ms passed.                           necessary.
                                                    Defective blade         Replace the blade motor.
                                                    motor.
                                                    Defective PWB.          Replace the centerfold main PWB or finisher
                                                                            main PWB and check for correct operation.
C8340   Centerfold staple motor problem             Poor contact in the     Check the connection of connector YC9 on
        (optional centerfold unit of 3000-sheet     connector termi-        the centerfold main PWB and the connector
        document finisher)                          nals.                   of the centerfold staple motor, and the conti-
        Jam89 is indicated.                                                 nuity across the connector terminals. Repair
                                                                            or replace if necessary.
                                                    Defective center-       Replace the centerfold staple motor.
                                                    fold staple motor.
                                                    Defective PWB.          Replace the centerfold main PWB or finisher
                                                                            main PWB and check for correct operation.
                                                                                                                      1-4-39
2GN/2GP/2GR
                                                                                 Remarks
  Code                  Contents
                                                           Causes           Check procedures/corrective measures
 C8350   Centerfold side registration motor 2        Poor contact in the   Check the connection of connector YC7 on
         problem (optional centerfold unit of        connector termi-      the centerfold main PWB and the connector
         3000-sheet document finisher)               nals.                 of centerfold side registration motor 2, and
         The home position is not detected when                            the continuity across the connector termi-
         initial operation even if 1000 ms passed.                         nals. Repair or replace if necessary.
                                                     Defective center-     Replace centerfold side registration motor 1.
                                                     fold side registra-
                                                     tion motor 2.
                                                     Defective PWB.        Replace the centerfold main PWB or finisher
                                                                           main PWB and check for correct operation.
 C8360   Centerfold main motor problem               Poor contact in the   Check the connection of connector YC12 on
         (optional centerfold unit of 3000-sheet     connector termi-      the centerfold main PWB and the connector
         document finisher)                          nals.                 of the centerfold main motor, and the conti-
         The motor lock signal is detected above                           nuity across the connector terminals. Repair
         1000 ms during driving the centerfold                             or replace if necessary.
         main motor.
                                                     Defective center-     Replace the centerfold main motor.
                                                     fold main motor.
                                                     Defective PWB.        Replace the centerfold main PWB or finisher
                                                                           main PWB and check for correct operation.
 C8440   Sensor adjusting problem (optional          The paper entry       Reinsert the connector. Also check for conti-
         document finisher)                          sensor connector      nuity within the connector cable. If none,
         The sensor cannot be adjusted within        makes poor con-       remedy or replace the cable.
         the specified range.                        tact.
                                                     Defective paper       Replace the paper entry sensor and check
                                                     entry sensor.         for correct operation.
                                                     The optical path of   Remove the foreign matter.
                                                     the paper entry
                                                     sensor is blocked
                                                     by foreign matter.
                                                     Defective finisher    Replace the finisher main PWB and check
                                                     main PWB.             for correct operation.
 C8460   EEPROM problem (optional document           Defective             Replace the finisher main PWB and check
         finisher)                                   EEPROM or fin-        for correct operation.
         Reading from or writing to EEPROM           isher main PWB.
         cannot be performed.
 C8500   Mail box communication error                Poor contact in the   Check the connection of the connector of
         (optional mail box of 3000-sheet doc-       connector termi-      the mail box and the connector YC7 on the
         ument finisher)                             nals.                 finisher main PWB, and the continuity
         Communication with the mail box is not                            across the connector terminals. Repair or
         possible although the connection is                               replace if necessary.
         detected.
                                                     Defective PWB.        Replace the mail box main PWB or finisher
                                                                           main PWB and check for correct operation.
1-4-40
                                                                                                       2GN/2GP/2GR
                                                                               Remarks
Code                   Contents
                                                        Causes            Check procedures/corrective measures
C8510   Mail box drive motor problem               Poor contact in the   Check the connection of connector YC2 on
        (optional mail box of 3000-sheet doc-      connector termi-      the mail box main PWB and the connector of
        ument finisher)                            nals.                 the mail box drive motor, and the continuity
        The motor lock signal is detected above                          across the connector terminals. Repair or
        500 ms during driving the mail box drive                         replace if necessary.
        motor.
                                                   Defective mail box    Replace the mail box drive motor.
                                                   drive motor.
                                                   Defective PWB.        Replace the mail box main PWB or finisher
                                                                         main PWB and check for correct operation.
C8800   Document finisher communication            Poor contact in the   Check the connection of connector on the
        problem (optional 3000-sheet docu-         connector termi-      finisher main PWB and the connector on the
        ment finisher)                             nals.                 engine PWB, and the continuity across the
        No communication: there is no reply                              connector terminals. Repair or replace if
        after 5 retries.                                                 necessary.
        Abnormal communication: a communica-
                                                   Defective PWB.        Replace the finisher main PWB or engine
        tion error (parity or checksum error) is
                                                                         PWB and check for correct operation.
        detected five times in succession.
C8900   Backup memory data problem                 Poor contact in the   Check the connection of connector on the
        (optional 3000-sheet document fin-         connector termi-      finisher main PWB and the connector on the
        isher)                                     nals.                 engine PWB, and the continuity across the
        Read and write data does not match.                              connector terminals. Repair or replace if
                                                                         necessary.
                                                   Defective finisher    Replace the finisher main PWB and check
                                                   main PWB.             for correct operation.
C8910   Backup memory data problem                 Poor contact in the   Check the connection of connector on the
        (optional punch unit of 3000-sheet         connector termi-      punch PWB and the connector YC4 on the
        document finisher)                         nals.                 finisher main PWB, and the continuity
        Read and write data does not match.                              across the connector terminals. Repair or
                                                                         replace if necessary.
                                                   Defective punch       Replace the punch PWB and check for cor-
                                                   PWB.                  rect operation.
C8920   Backup memory data problem                 Poor contact in the   Check the connection of connector on the
        (optional mail box of 3000-sheet doc-      connector termi-      mail box main PWB and the connector YC7
        ument finisher)                            nals.                 on the finisher main PWB, and the continuity
        Read and write data does not match.                              across the connector terminals. Repair or
                                                                         replace if necessary.
                                                   Defective mail box    Replace the mail box main PWB and check
                                                   main PWB.             for correct operation.
C8930   Backup memory data problem                 Poor contact in the   Check the connection of connector on the
        (optional centerfold unit of 3000-sheet    connector termi-      centerfold main PWB and the connector
        document finisher)                         nals.                 YC5 on the finisher main PWB, and the con-
        Read and write data does not match.                              tinuity across the connector terminals.
                                                                         Repair or replace if necessary.
                                                   Defective center-     Replace the centerfold main PWB and
                                                   fold main PWB.        check for correct operation.
                                                                                                               1-4-41
2GN/2GP/2GR
                                                                                   Remarks
  Code                   Contents
                                                            Causes            Check procedures/corrective measures
 C9000   DP communication problem                     Poor contact in the    Check the connection of connector YC7 on
         (optional DP)                                connector termi-       the scanner PWB and the connector of the
         A communication error is detected.           nals.                  DP, and the continuity across the connector
                                                                             terminals. Repair or replace if necessary.
                                                      Defective DP main      Replace the DP main PWB and check for
                                                      PWB.                   correct operation.
 C9040   DP lift motor going up error                 Loose connection       Reinsert the connector. Also check for conti-
         (optional DP)                                of the DP lift motor   nuity within the connector cable. If none,
         The pulse count raised to 10000 at lift-     connector.             remedy or replace the cable.
         ing, however, the DP lift switch could not
                                                      Malfunction of the     Replace the DP lift motor and check for cor-
         be turned on. After one time retry, the DP
                                                      DP lift motor.         rect operation.
         lift limit switch could not be turned on.
                                                      Malfunction of the     Replace the DP lift upper limit switch and
                                                      DP lift upper limit    check for correct operation.
                                                      switch.
                                                      Loose connection       Reinsert the connector. Also check for conti-
                                                      of the DP lift upper   nuity within the connector cable. If none,
                                                      limit switch con-      remedy or replace the cable.
                                                      nector.
                                                      Defective DP main      Replace the DP main PWB and check for
                                                      PWB.                   correct operation.
 C9050   DP lift motor going down error               Loose connection       Reinsert the connector. Also check for conti-
         (optional DP)                                of the DP lift motor   nuity within the connector cable. If none,
         The pulse count lowered to 10000 at lift-    connector.             remedy or replace the cable.
         ing down, however, the DP bottom limit
                                                      Malfunction of the     Replace the DP lift motor and check for cor-
         switch could not be turned on.
                                                      DP lift motor.         rect operation.
         After one time retry, the DP bottom limit
         switch could not be turned on.               Malfunction of the     Replace the DP lift lower limit switch and
                                                      DP lift lower limit    check for correct operation.
                                                      switch.
                                                      Loose connection       Reinsert the connector. Also check for conti-
                                                      of the DP lift lower   nuity within the connector cable. If none,
                                                      limit switch con-      remedy or replace the cable.
                                                      nector.
                                                      Defective DP main      Replace the DP main PWB and check for
                                                      PWB.                   correct operation.
 C9060   DP EEPROM error (optional DP)                Defective DP main      Replace the DP main PWB and check for
         Read and write data does not match.          PWB.                   correct operation.
         Data in the specified area of the backup
                                                      Device damage of       Contact the Service Administrative Division.
         memory does not match the specified
                                                      EEPROM.
         values.
 C9070   Communication problem between DP             Loose connection       Reinsert the connector. Also check for conti-
         and SHD (optional DP)                        of the SHD PWB.        nuity within the connector cable. If none,
         A communication error is detected.                                  remedy or replace the cable.
                                                      Defective SHD          Replace the SHD PWB and check for cor-
                                                      PWB.                   rect operation.
 C9080   Communication problem between DP             Loose connection       Reinsert the connector. Also check for conti-
         and CIS (optional DP)                        of CIS.                nuity within the connector cable. If none,
         Reading cannot be performed correctly.                              remedy or replace the cable.
                                                      Defective CIS.         Replace CIS and check for correct opera-
                                                                             tion.
1-4-42
                                                                                           2GN/2GP/2GR
                                                                     Remarks
Code                Contents
                                                Causes         Check procedures/corrective measures
F000   Operation panel PWB communication   Defective main      Replace the main PWB and check for cor-
       error                               PWB.                rect operation.
                                           Defective opera-    Replace the operation panel PWB and
                                           tion panel PWB.     check for correct operation.
F010   Main PWB checksum error             Defective main      Replace the main PWB and check for cor-
                                           PWB.                rect operation.
F020   Memory checksum error               Defective main      Replace the main PWB and check for cor-
                                           PWB.                rect operation.
                                           Defective expan-    Replace the expansion memory and check
                                           sion memory.        for correct operation.
F030   Main PWB system error               Defective main      Replace the main PWB and check for cor-
                                           PWB.                rect operation.
F040   Engine PWB communication error      Defective main      Replace the main PWB and check for cor-
                                           PWB.                rect operation.
                                           Defective engine    Replace the engine PWB and check for cor-
                                           PWB.                rect operation.
F041   Scanner PWB communication error     Defective main      Replace the main PWB and check for cor-
                                           PWB.                rect operation.
                                           Defective scanner   Replace the scanner PWB and check for
                                           PWB.                correct operation.
F050   Engine ROM checksum error           Defective engine    Replace the engine PWB and check for cor-
                                           PWB.                rect operation.
F060   Engine RAM error                    Defective engine    Replace the engine PWB and check for cor-
                                           PWB.                rect operation.
F070   Flash ROM error                     Defective flash     Replace the flash ROM and check for cor-
                                           ROM.                rect operation.
F080   Flash ROM error (during download)   Defective flash     Replace the flash ROM and check for cor-
                                           ROM.                rect operation.
F090   Fax control PWB communication       Defective main      Replace the main PWB and check for cor-
       error                               PWB.                rect operation.
1-4-43