Catnic Lintels
Catnic Lintels
Uniclass                 EPIC
    L325:P4142              F631:X442
   Cl/Sfb        (31.9)   Hh2
   August 2006
Catnic
            August 2006
9616 Catnic Lintel Brochure   2/8/06   12:40   Page ii
9616 Catnic Lintel Brochure   2/8/06   12:40   Page 1
                                               Contents
                                   Page        Introduction
                                        2      Leaders in Technical Innovation
                                        3      Help When You Need It
                                        4      Catnic Service Package
                                               Lintel Guidelines
                                        5      How to Select a Lintel
                                        6      Catnic Lintel Benefits
                                       10      Lintel Selector - Cavity Walls
                                       11      Lintel Selector - All Products
                                       12      Installing a Cavity Wall Lintel
                                       13      Installing a Lintel Supporting Concrete Floors
                                               Products
                                       14      Cougar Open Back Lintels
                                       24      Classic Combined Box Lintels
                                       25      CXL Lintels
                                       28      Cavity Wall Eaves Lintels
                                       32      Timber Frame Lintels
                                       35      Installing a Timber Frame Lintel
                                       36      External Solid Wall Lintels
                                       40      Internal Partition and Loadbearing Wall Lintels
                                               Extended Range
                                       46      Standard Arch Lintels
                                       47      Bespoke Lintels
                                       48      Fabricated Arch Lintels
                                       49      Enquiry Form - Fabricated Arch Lintels
                                       50      Fabricated Corner and Bay Lintels
                                       51      Enquiry Form - Fabricated Bay Lintels
                                       52      Corner Lintels
                                       53      Enquiry Form - Bay and Corner Lintels
                                               Accessories
                                       55      Lintel Arch Centres
                                       56      Stop Ends
                                       57      Weep Vents and Soffit Cladding
                                               Technical Specifications & Quality Assurances
                                       58      Where to Use a Separate DPC
                                       59      Quality Assurance
                                       60      Technical Information
                                       61      The Environment
                                       62      Technical Specification & Glossary
                                       63      Technical Enquiry Request Form
                                       64      Notes Page
                                       65      Other Catnic Products
           Catnic - Leaders in
           Technical Innovation
           Catnic has pioneered the steel lintel for more than three generations and designs,
           manufactures and supplies the construction industry with technically superior
           products. Catnics reputation has been earned through constant technical innovation
           and leading the UK lintel market.
           Far from just leading, Catnic in fact has worked over the
           years with the BSI to establish the standards for lintels
           in this country, and continues to develop and invest in
           improving on these standards with its extensive range of
           products and unique features.
        Catnic is committed to providing the building industry    Catnics sales and technical teams are dedicated to
        with new and improved products, borne from investment     matching the quality of our products with the excellence
        in design and manufacturing technologies.                 of our service, from the professional voice at the end of
                                                                  the telephone to our on-site consultation.
        Catnic means:
         The strongest brand in the industry                     Full service support for customers
         A partnership approach to the way we work               Catnic has been at the forefront of lintel design for over
         Dedicated haulier - liveried lorries                    35 years. Our reputation for exceptional quality and
         Servicing builders, architects, specifiers              technical expertise has ensured customers satisfaction
         and merchants                                            and loyalty in the products and services that we offer.
         Committed to both national and independent
         merchants                                                Catnics team:
         Investment in plant and machinery and the latest         Are professional and experienced
         technologies                                              Are extensively trained
         Continuously dedicated to research and development       Have comprehensive product and industry knowledge
         of the industry and our product offering                  Have a committed parent company who are Investors
                                                                   in People  Corus.
        We hope that you will find this Lintel Product Selector
        both useful and informative. Should you require any                                               visit
                                                                                                       our website
        further assistance or information about our other
        product ranges then please call us on 029 2033 7900.                              www.                               .com
                                                                                                                        om
                                                                                                       w
                                                                                                        w
                                                                                                            w.
                                                                                                                 c atnic.c
                                                                             Technical support
                                                                             Experienced engineers qualified in construction enable Catnic
                                                                             to offer an advisory service to anyone engaged on building
                                                                             projects, regardless of size, from a private house extension, to
                                                                             a major housing development or commercial building.
           Built in DPC  Conforms to NHBC required            Product Benefits & Design Features
           profile. No additional DPC is required in many       Self - weight of lintel allows easy handling solutions
           areas of the UK, making construction quicker         Profile shape designed for use without a separate DPC,
           and easier, giving extra peace of mind but also      whilst providing additional support when required
           saving on time and cost. Where a DPC is              BBA and BSI kitemark certified products
           required, the lintel profile is shaped to support    Corrosion protected
           the DPC during construction.                         Safe working lintel loads are provided throughout this
                                                                product selector with reference to various differential
                                                                loading arrangements which are common to traditional
                                                                cavity wall construction
        The Black Lintel = Improved Corrosion Protection                  The protection system complies fully with the chemical and
        Many Catnic lintels employ not one but two methods of             physical test requirements outlined in Table 2 of BS5977:
        protection against corrosion attack: the unique,                  PART 2: 1983 for lintels having their own built-in Damp
        sophisticated Duplex double protection system.                    Proof Course (DPC).
           Catnic Lintels
           Our rigid adherence to quality control and compliance
           is your guarantee of technical superiority
            Catnics Cougar Open Back (page 14) lintels are easy to       Load ratios
           use profiles allowing masonry to be built up continuously on    Safe working loads, as defined by BS 5977: Part 2 for
           both the inner and outer leaves saving time and cost on         cavity wall lintels refer to uniform distributed loads
           site. Cougars are fully insulated by moulding expanded          applied in the inner to outer leaf ratios:
           polystyrene bead into the CG style lintel, forming a ribbed
                                                                            1:1 For lintels supporting masonry only
           finish on the underside to provide a plaster key. The rigid
                                                                            3:1 For lintels normally carrying timber floors
           slotted base on CL & CU lintels provides plaster adhesion
                                                                            5:1 For lintels normally carrying concrete floors
           and avoids the hazards of working with mesh.
                                                                           The CL & CU lintel range refers to uniformly distributed
           Parts L1 & L2 of the Building Regulations                       loads in the ratio of 19:1 when non standard or unusual
           Approved Documents                                              loading conditions occur.
           Catnics lintels comply with the amended Approved
           Document L regulations. Catnics compliance illustrates their
           position as technical leaders, always striving for continuous
           improvement in more energy efficient construction practices.
        Material
        Catnic Cougar and Classic lintels are manufactured from
        high quality grade galvanised steel to BS EN 10327:2004
        DX51D & Z275, with a black coloured polyester resin finish.
        Damp Proof Course                                              Quality control checks on the incoming steel include:
        The design of Catnic Cougar open back and combined              Dimensional tolerances
        box lintels incorporates a built in DPC, and any water          Mechanical properties
        penetrating the cavity automatically transfers across the       Thickness
        sloping face of the lintel and is disposed of externally. In    Quality of the galvanising
        areas of sheltered to medium exposed weather conditions
        there is no need to install a separate DPC.                    Quality control checks during manufacture include:
                                                                        Dimensions
        Quality                                                         Thickness
        Catnic lintels are manufactured to the highest quality and      Weld quality
        are continually assessed both internally and by numerous        Quality and accuracy of the black coating
        external, independent organisations. All quality assurance      Insulation
        systems comply with BS EN ISO 9001: 2000.
Inner Block size (mm) Cavity 50-65mm Page Cavity 70-85mm Page Cavity 90-105mm Page
           Note:
           The above table represents our standard stock range of cavity wall lintels. For any requirements that fall outside of these
           parameters please contact Technical Services on 029 2033 7900 for advice on Catnics extensive range of special lintels
125-140 50-65 102 CG50/125, CGH50/125, CLA50/125, Wide Inner Leaf Open Back Lintel 19
125-140 70-85 102 CG70/125, CGH70/125, CLA70/125, Wide Inner Leaf Open Back Lintel 21
125-140 90-105 102 CG90/125, CGH90/125, CLA90/125, Wide Inner Leaf Open Back Lintel 23
100-115 50 140-150 CN42, CN99/124 Combined Box Lintel Wide Outer Leaf 24
125-140 50-85 N/A CGE50/125 Wide Inner Leaf Open Back Eaves Lintel 30
125-140 90-105 N/A CGE90/125 Wide Inner Leaf Open Back Eaves Lintel 30
                                                                                                                                        Ensure a nominal
                                                                                                                                        150mm end bearing
                         Ensure lintel is
                                                                                                                                        at each end.*
                         not damaged.
                                                                            Structural opening
                                                                              or clear span.
           Additional notes
           Do                                                                            Do not
            Install a separate DPC in severe exposure conditions.                        Use damaged lintels
             A Catnic Cougar Open Back or Classic Combined Box
                                                                                          Apply point loads without prior consultation. Where the
             lintel with an additional DPC membrane installed in
                                                                                           loading or a substantial part of it is applied as
             accordance with normal practice provides the best
                                                                                           concentrated loads, each concentrated load must be
             possible protection (page 58)
                                                                                           supported over a length of lintel of not less than 200mm.
            Locate the window/door frame so that the drip on the                          In such cases, the total loading must not produce
             front of the lintel projects forward of the drip on the front                 bending moments or shear forces greater than those
             of the frame. It is good building practice to insert a                        produced by the uniformly distributed loads specified in
             flexible joint between the lintel and the top of the frame                    the relevant data tables
            Ensure that timber floor joists and roof trusses have a                      Allow blockwork to overhang the lintel by more
             full block depth between them and the lintel flange on                        than 25mm
             Cougar Open Back Lintels
                                                                                          Apply concrete floor loads without ensuring that the total
            Refer to the Catnic How to Install a Lintel Supporting                       loads are checked by a structural engineer, or by Catnic
             Concrete Floors or the Steel Lintel Manufacturers                            Technical Services
             Association guidelines (available on request) when using
                                                                                          Do not cut CG or CGH type lintels under any
             Classic Combined Box or CL & CU Open Back Lintels to
                                                                                           circumstances
             support concrete floors
                                                                                          Apply point loads directly on lintel flanges
            Consider the use of our soffit cladding for all coastal
             sites (refer to page 56 & 57)
                                                                                                       Lintel
                                                                                                                           Brick outer leaf
           Typical applications
           CG
            Triangulated masonry load
            Supporting uniformly distributed masonry load
            Supporting uniformly distributed timber floor and
              roof loads
            Suitable for fair faced inner leaf masonry
           CGH
           As above plus:
            Increased loading conditions                                                                CG Lintel
            Uneven loading situations
            Nominal point loading eg. stair trimmers, stud
              partition supports, etc.
           CL & CU
           As above plus:
            Supports concrete floors
            Attic truss loads                                                                                                          CU Lintel
                                                                                                         Benefits
            Larger span multiple truss loads
                                                                                                          Materials used in Lintels
                                                                                                            The CG, CGH, CL and CU ranges are formed from
           Conditions of use
                                                                                                            galvanised steel, then powder coated
            Nominal 150mm end bearings
            Both leaves are raised together
                                                                                                          Integral insulation
            One course of block prior to installation of floor/roof
                                                                                                            Maximising thermal efficiency, minimising cold bridging
            Refer to Installing a cavity wall lintel (page 12)
           Note: For a definition of these terms see the Glossary                                         Duplex corrosion protection
           of Technical Terms on page 62                                                                    Ensures optimum durability and longevity
                                                                                                          Built-in DPC
                                                                                                            Saves time in construction, and means cavity is easy to
                                                                                                            clean without risk of damage to DPC (refer to page 58)
                                                                                                          Accessories
                                                                                                            ArchCentres, Stop Ends, Cavity Weep Vents, Soffit
                                                                                                            Cladding (refer to page 54)
           NOTE: Whilst the above information is intended to offer general guidance regarding typical applications, it should not be considered as comprehensive. Requirements not fully covered
           by the above should be referred to our technical services department for individual consideration.
         Lightweight plaster or
         plasterboard
         Insulated plasterboard
         (Gyproc Thermal Board
         LD or similar approved)
         to soffit area
100 48 95
            CGH50/100
            Standard lengths (mm)                    900-1200           1350-1500             1650-1800              1950-2100
            SWL 1:1/3:1 (kN)                               23                    29                  34                        40
            Weight (kg/m)                                 9.5                  11.1                 14.2                   16.2
            Nominal height h (mm)                       140                  180                  180                        220
            CU50/100
            Standard lengths (mm) 2100-3000 3300-3900                                         4200-4800                                      Note: To achieve the CL & CU loading
                                                                                                                                             figures indicated, lintels must be built-in
            SWL 1:1/19:1 (kN)                              74                    47                  29                                      as illustrated, ensuring that the blockwork
                                                                                                                                             infill is well-jointed during construction and
            Weight (kg/m)                                19.4                  19.4                19.4                                      compatible with the strength of the
                                                                                                                                             masonry above.
            Nominal height h (mm)                       232                  232                  232
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
                                                                                                                                             Continuous
                                                                                                                                             solid infill
                                                                         Continuous                                                          block
                                                                         solid infill
                                                                         block
125 48 95
         CGH50/125*
         Standard lengths (mm) 900-1200                             1350-1500            1650-1800              1950-2100
         SWL 1:1/3 :1 (kN)                            23                   29                   34                        40
         Weight (kg/m)                               10.0                 11.6                 14.8                       16.8
         Nominal height h (mm)                      140                 180                  180                        220
         CU50/125
         Standard lengths (mm) 2100-3000 3300-3900                                       4200-4800                                      Note: To achieve the CL & CU loading
                                                                                                                                        figures indicated, lintels must be built-in
         SWL 1:1/19:1 (kN)                            74                   47                   29                                      as illustrated, ensuring that the blockwork
                                                                                                                                        infill is well-jointed during construction and
         Weight (kg/m)                              19.76               19.76                 19.76                                     compatible with the strength of the
                                                                                                                                        masonry above.
         Nominal height h (mm)                     232                  232                  232
        Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
        The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
* For applications incorporating 140mm solid aggregate concrete blocks, contact our Technical Services Department on 029 2033 7900
                                                                                                                                         Continuous
                                                                                                                                         solid infill
                                                                    Continuous                                                           block
                                                                    solid infill
                                                                    block
100 68 95
            CG70/100
            Standard lengths (mm) 750-1500                              1650-1800             1950-2100             2250-2400               2550-2700             2850-3000                  3300-3900
            SWL 1:1/3 :1 (kN)                              15                    18                  20                     22                   26                      26                         26
            Weight (kg/m)                                5.98                  7.48                 8.1                    8.7                  9.98                  12.46                      16.29
            Nominal height h (mm)                       140                  140                  160                    180                  220                    220                          220
           CGH70/100
            Standard lengths (mm) 900-1200                              1350-1500             1650-1800             1950-2100
            SWL 1:1/3 :1 (kN)                              23                    29                  34                     40
            Weight (kg/m)                                 9.7                  11.3                14.5                   16.5
            Nominal height h (mm)                       140                  180                  180                    220
            CU70/100
            Standard lengths (mm) 2100-3000 3300-3900                                         4200-4800                                     Note: To achieve the CL & CU loading
                                                                                                                                            figures indicated, lintels must be built-in
            SWL 1:1/19:1 (kN)                              74                    47                  29                                     as illustrated, ensuring that the blockwork
                                                                                                                                            infill is well-jointed during construction and
            Weight (kg/m)                               19.91                 19.91                19.91                                    compatible with the strength of the
                                                                                                                                            masonry above.
            Nominal height h (mm)                       232                  232                  232
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
                                                                                                                                         Continuous
                                                                                                                                         solid infill
                                                                                                                                         block
                                                                         Continuous
                                                                         solid infill
                                                                         block
125 68 95
         CG70/125*
         Standard lengths (mm) 750-1200                              1350-1800             1950-2400            2550-2700             2850-3000
         SWL 1:1/3 :1 (kN)                             12                   17                   20                        26                   26
         Weight (kg/m)                                6.33                7.95                  9.18                 13.07                  16.9
         Nominal height h (mm)                      140                  140                  180                    220                  220
         CGH70/125*
         Standard lengths (mm) 900-1200                              1350-1500             1650-1800            1950-2100
         SWL 1:1/3 :1 (kN)                             23                   29                   34                        40
         Weight (kg/m)                                10.2                11.8                  15.1                  17.1
         Nominal height h (mm)                      140                  180                  180                    220
        CU70/125
         Standard lengths (mm) 2100-3000 3300-3900                                         4200-4800                                        Note: To achieve the CL & CU loading
                                                                                                                                            figures indicated, lintels must be built-in
         SWL 1:1/19:1 (kN)                             74                   47                    29                                        as illustrated, ensuring that the blockwork
                                                                                                                                            infill is well-jointed during construction and
         Weight (kg/m)                               20.27               20.27                 20.27                                        compatible with the strength of the
         Nominal height h (mm)                      232                  232                   232                                        masonry above.
        Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
        The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
* For applications incorporating 140mm solid aggregate concrete blocks, contact our Technical Services Department on 029 2033 7900
                                                                                                                                             Continuous
                                                                                                                                             solid infill
                                                                           Continuous                                                        block
                                                                           solid infill
                                                                           block
100 88 95
           CG90/100
           Standard lengths (mm) 750-1500                               1650-1800             1950-2100            2250-2400              2550-2700              2850-3000                  3300-3900
           SWL 1:1/3 :1 (kN)                              15                   18                    20                   22                        26                     26                      26
           Weight (kg/m)                                 6.13                7.63                  8.26                  8.88                  10.15                  12.96                       16.6
           Nominal height h (mm)                       140                  140                   160                  180                     220                       220                    220
           CGH90/100
           Standard lengths (mm) 900-1200                               1350-1500             1650-1800            1950-2100
           SWL 1:1/3 :1 (kN)                              23                   29                    34                   40
           Weight (kg/m)                                 10.0                11.6                  14.8                  16.8
           Nominal height h (mm)                       140                  180                   180                  220
           CU90/100
           Standard lengths (mm) 2100-3000 3300-3900                                          4200-4800                                   Note: To achieve the CL & CU loading
                                                                                                                                          figures indicated, lintels must be built-in
           SWL 1:1/19:1 (kN)                              74                   47                    29                                   as illustrated, ensuring that the blockwork
                                                                                                                                          infill is well-jointed during construction and
           Weight (kg/m)                                20.48               20.48                 20.48                                   compatible with the strength of the
           Nominal height h (mm)                       232                  232                   232                                   masonry above.
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
                                                                                                                                          Continuous
                                                                                                                                          solid infill
                                                                                                                                          block
                                                                             Continuous
                                                                             solid infill
                                                                             block
        Cavity Walls
                                                                                                                                                                           125           88         95
125 88 95
        CG90/125*
        Standard lengths (mm) 750-1200                               1350-1800             1950-2400             2550-2700             2850-3000
        SWL 1:1/3:1 (kN)                               12                   17                    20                       26                 26
        Weight (kg/m)                                  6.5                8.13                  9.36                  13.28                  17.2
        Nominal height h (mm)                       140                  140                   180                   220                   220
        CGH90/125*
        Standard lengths (mm) 900-1200                               1350-1500             1650-1800             1950-2100
        SWL 1:1/3:1 (kN)                               23                   29                    34                       40
        Weight (kg/m)                                 10.4                12.0                  15.4                   17.4
        Nominal height h (mm)                       140                  180                   180                   220
        CU90/125
        Standard lengths (mm) 2100-3000 3300-3900                                          4200-4800                                         Note: To achieve the CL & CU loading
                                                                                                                                             figures indicated, lintels must be built-in
        SWL 1:1/19:1 (kN)                              74                   47                    29                                         as illustrated, ensuring that the blockwork
                                                                                                                                             infill is well-jointed during construction and
        Weight (kg/m)                                20.85               20.85                 20.85
                                                                                                                                             compatible with the strength of the
        Nominal height h (mm)                       232                  232                   232                                         masonry above.
        Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
        The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
* For applications incorporating 140mm solid aggregate concrete blocks, contact our Technical Services Department on 029 2033 7900
                                                                                                                                        Continuous
                                                                                                                                        solid infill
                                                                      Continuous                                                        block
                                                                      solid infill
                                                                      block
           CN42C
           Standard lengths (mm)                 750-4200
                                                                                                                                                              100      50      130
           SWL 1:1/5:1 (kN)                            29
           Weight (kg/m)                             20.5
                                                                                                                                          nominal
                                                                                                                                                      h
                                                                                                                                          height (see
           Nominal height h (mm)                    219                                                                                 tables below)
           CN99/124C
           Standard lengths (mm)                 750-4200
                                                                                                                                                              100      70       130
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4200mm
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
CXL Lintels
            Longer spans
             High loads at longer spans
            Varying widths
             Suits a variety of wall widths  with special widths
             on application
Applications
        Cavity Walls
                                                                                                                            133                      133                             133
                                                                                                                                       6                              6                          6
                                                                                                                              234                          259                             284
         CXL240
         Standard lengths (mm) 2100-3000                          3300-4800              5100             5400               5700          6000                     6300              6600
         SWL 5:1/19:1(kN)                            88                  83                78               71                    64         56                      52                    47
         Weight (kg/m)                             41.1                41.1               41.1            41.1                41.1          41.1                    41.1              41.1
         Ixx (cm ) 4
                                                   4051                4051              4051             4051               4051          4051                     4051              4051
         Zxx (cm3)                                  303                 303               303              303                303           303                     303                303
         Serviceability moment (kNm)                 50                  50                50               50                    50         50                      50                    50
         Allowable reaction (kN)                     68                  68                68               68                    68         68                      68                    68
The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 200mm end bearings.
         Eaves Lintels
          Closed eaves lintels are manufactured from
          galvanised steel and powder coated for extra
          protection. Available in both Cougar open back or
          Classic box styles
         Integral insulation
          Maximising thermal efficiency, minimising
          cold bridging
         Extended durability
          Duplex system providing twice the protection
           Closed Eaves
           Cougar Open Back
            CGE50/100
            Standard lengths (mm)                   750-1500           1650-2100                 2400                  2700                                               100       48        60
            SWL (kN)*                                     25                  22                   20                    20
                                                                                                                                                                  h
            Weight (kg/m)                                7.0                 8.0                  10.2                 10.2
            Nominal height h (mm)                       95                 115                  115                   115                                                     CGE50/100
            CGE50/125
            Standard lengths (mm) 900-1500                             1650-2100                 2400                  2700                                              125         48       60
            SWL (kN)*                                     25                  25                   25                    25
                                                                                                                                                           h
            Weight (kg/m)                                8.3                 9.3                  11.9                 11.9
            Nominal height h (mm)                      115                 140                  140                   140                                                      CGE50/125
            CGE90/1000
                                                                                                                                                                          100         88           60
            Standard lengths (mm) 750-1500                             1650-2100                 2400                  2700
            SWL (kN)*                                     25                  22                   20                    20
                                                                                                                                                                  h
            Weight (kg/m)                                7.7                 8.3                  10.7                 10.7
            Nominal height h (mm)                       95                 115                  115                   115                                                       CGE90/100
            CGE90/125
                                                                                                                                                                        125              88        60
            Standard lengths (mm) 900-1500                             1650-2100                 2400                  2700
            SWL (kN)*                                     25                  25                   25                    25
                                                                                                                                                            h
           Standard lengths are available in increments of 150mm, except for 2250mm and 2550mm.
           *To achieve the stated safe working load (SWL), closed eaves lintels must be built in with solid blockwork and continuous timber wall-plates. Allow 150mm at each end for bearing support.
        Closed Eaves
        Classic Box
        Typical applications
         Universal application caters for all loading conditions
         Direct roof loading
         Attic truss loads
         Supports point loads e.g. multiple trusses
         CN55A
         Standard lengths (mm) 900 &1200                             1500      1650-2100 2400&2700
         SWL (kN)                                   30                30          25        20
         Weight (kg/m)                              9.0               9.0        9.0        9.0
                                                                                                                 100   75
        Standard lengths are available in increments of 150mm.
        For lengths over 2700mm please contact Technical Services.
143
CN55C CN55
Eaves Lintel
         Restraint clips
          Allows vertical differential movement of timber frame
         Accessories
          ArchCentres, Stop Ends, Cavity Weep Vents,
          Soffit Cladding (refer to page 57)
        Lintels for timber frame construction are supplied with lintel restraint clips (free of charge), which must be screw or
        nail fixed to the timber frame, to allow for differential movement between the timber structure and the brick facing.
                                                                                                Lintel      Number
        Lintel code      Length (mm)        Clip fixings                                        Length (mm) of clips
        CTF5, 6 & 7      750-3600           50mm x 3.35mm diam. Plain head galvanised nails     Up to 1800           3
        CTF5, 6 & 7      3900-4800          38mm x No10 RD/HD sherardised wood screws           1950-3000            5
        CN23             Up to 4800         38mm x No10 RD/HD sherardised wood screws           3300-4200            7
                                                                                                4575-4800            9
38 95
           Cavity Walls
                                                                                                     47   95                 60     95                 67        95
           Timber Frame
                                                                                                                   h                          h                   h             h
            CTF5
            Standard lengths (mm) 750-1200                          1350-1500           1650-2400              2550-3000          3300-3600           3900-4800
            SWL (kN)                                    4                  5                    7                   7                     9                 10
            Weight (kg/m)                              3.8                4.8                 5.6                 7.2                     8.0               9.0
            Nominal height h (mm)                   128                128                  183                 183                    218            256
            CTF6
            Standard lengths (mm) 750-1200                          1350-1500           1650-2400              2550-3000          3300-3600           3900-4800
            SWL (kN)                                    4                  5                    7                   7                     9                 10
            Weight (kg/m)                             4.48                5.6                5.88                7.28                    8.03           9.05
            Nominal height h (mm)                   170                170                  187                 187                    222            265
            CTF7
            Standard lengths (mm) 750-1200                          1350-1500           1650-2400              2550-3000          3300-3600           3900-4800
            SWL (kN)                                    4                  5                    7                   7                     9                 10
            Weight (kg/m)                             4.18               5.23                5.88                7.52                    8.29           9.35
            Nominal height h (mm)                   145                145                  187                 187                    218            265
            CN23B                                                                      CN23C
            Standard lengths (mm) 750-3600                                              3900-4800
            SWL (kN)                                   10                                      10
            Weight (kg/m)                            12.8                                    16.3
            Nominal height h (mm)                   268                                     268
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm.
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
         When propping, a horizontal board should be placed                       The prop can be removed after the mortar has cured
            along the flat underside of the lintel soffit; this will                   and the wall ties become effective.
            prevent any point loading, which could cause localised
                                                                                   A timber pinch batten should be fixed at the heel of the
            deformation of the lintel flange.
                                                                                       timber frame lintel in order to minimise any rotation.
         On small openings a single prop should be placed
                                                                                   Catnic timber frame lintels (e.g. CTFs) are intended only
            centrally within the opening and gently wedged into place.
                                                                                       to support an outer skin of brickwork where it is tied to
         The number of props should be increased for larger                           an inner skin of timber frame and must be suitably
            openings. Generally props should be installed at                           propped during construction.
            maximum centres of 1 metre.
Centre of lintel
                                                                Pinch batten       Lintels for timber frame construction are supplied with
                                                                                   lintel restraint clips (free of charge), which must be
                                                         Timber frame              screw or nail fixed to the timber frame, as shown on
                                                                                   page 33, to allow for differential movement between the
                                                                                   timber structure and the brick facing.
Clearance 1950-3000 5
                                                                                           Clearance                                3300-4200           7
      Brick outer leaf                                                                                                              4575-4800           9
         Integral insulation
          Maximising thermal efficiency
         Staggered slots
          Minimises cold bridging
         Box section
          Resists twisting during construction
                                                                            External Solid Wall CN71 Lintel
                                                                                                                                                                     h    nominal
           For 200 & 215mm Exterior Solid Walls                                                                                                                             height (see
                                                                                                                                                                            tables below)
            CN71A                                                                                                           CN71C
            Standard lengths (mm) 750-1500                        1650-2100          2250-2700                               900-1500           1650-1950
            SWL (kN)                                 29                 27                 20                                     49                  44
            Weight (kg/m)                            9.3               9.3                 9.3                                   14.6                14.6
            Nominal height h (mm)                  143               143                143                                     143                143
           CN81B                                                                    CN81C
            Standard lengths (mm) 2100-3600                                          2100-2700           2850-3300               3600           3900-4575                  4800
            SWL (kN)                                 29                                    54                  47                 39                  29                     26
            Weight (kg/m)                            15.1                                 18.5                18.5               18.5                18.5                  18.5
            Nominal height h (mm)                  219                                  219                 219                 219                219                    219
            CN99/394C
            Standard lengths (mm) 3000-3300 3600-3900                                4200-4800
            SWL (kN)                                 54                 51                 49
            Weight (kg/m)                            22.3             22.3                22.3
            Nominal height h (mm)                  295               295                295
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
55
100 91 182
        For 102 & 215mm Exterior Solid Walls                                                                          CN48 & CN49            CNZ94, CNZ95,      CN50 & CN51
                                                                                                                                             CNZ96 & CNZ97
         CN48C                                                                           CN49C
         Standard lengths (mm) 750-1800                                                    1950-2700
         SWL (kN)                                      15                                        20
         Weight (kg/m)                                 7.5                                       9.3
         Nominal height h (mm)                      154                                       229
        Lintels CN48 and CN49 should be suitably propped and laterally restrained during construction.
        To achieve loading figures, lintels must be constructed with brickwork (blockwork) fully built-in as shown.
         CNZ96C                                                                           CNZ97C
         Standard lengths (mm) 2250-2400                                                   2550-2700
         SWL (kN)                                      10                                        15
         Weight (kg/m)                                 6.3                                       7.5
         Nominal height h (mm)                      167                                       215
        Lintels CNZ94, CNZ95, CNZ96 and CNZ97 should be suitably propped and laterally restrained during construction.
        Profile CNZ94A is designed for use over meter boxes only.
         CN50C                                                                            CN51C
         Standard lengths (mm) 750-1800                                                    1950-2700
         SWL (kN)                                      10                                        12
         Weight (kg/m)                                 9.0                                      12.7
         Nominal height h (mm)                       91                                       167
        Typical applications
        CN92 & CN102
         Suitable for nominal domestic loading
        CN100
        As above plus:
         Suitable for masonry and timber floor loads
          Note: 1800 and 2100mm lengths are not suitable
          for floor loads
                                                                                         Box profiles
                                                                                           Sized to suit brick or block course heights. Use box
                                                                                           profiles for heavier loads and wider openings,
        Typical application showing CN5X box profile lintel in 100mm wall
                                                                                           manufactured from galvanised steel with additional
                                                                                           polyester powder coating
                                                                                         Plaster/mortar keys
                                                                                           Incorporated in all lintels
        NOTE: Whilst the above information is intended to offer general guidance regarding typical applications, it should not be considered as comprehensive.
        Requirement not fully covered by the above should be referred to our technical services department for individual consideration.
68 98
           Note: When using CN92 and CN102 lintels normal building practice should be observed, in that one course of blockwork should be laid on
           the lintel and the mortar allowed to harden for at least 24 hours before additional loads are applied.
103 (inside)
                                                                                                                                                             nominal
                                                                                                                                                             height (see     h
           For 100mm Interior Solid Walls                                                                                                                    tables below)
            CN5XA                                                                                                                  CN5XC
            Standard lengths (mm) 750-1500                            1650-2100           2250-2700                                  750-1500       1650-1950
            SWL (kN)                                    29                  25                   20                                        49              39
            Weight (kg/m)                               7.6                 7.6                  7.6                                     12.3              12.3
            Nominal height h (mm)                    143                 143                  143                                       143              143
           CN6XB                                                                          CN6XC
            Standard lengths (mm) 2100-3600                                               2100-2700            2850-3300                 3600       3900-4575                       4800
            SWL (kN)                                    29                                       49                   39                   34              29                        26
            Weight (kg/m)                              12.4                                     15.7                15.7                 15.7              15.7                     15.7
            Nominal height h (mm)                    219                                      219                  219                  219              219                      219
            CN99/438C
            Standard lengths (mm) 3000 -3300 3600 - 3900 4200-4800
            SWL (kN)                                    54                  51                   41
            Weight (kg/m)                              19.5                19.5                 19.5
            Nominal height h (mm)                    295                 295                  295
           Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
           The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
                                                                                                                                                                nominal
                                                                                                                                                                height (see     h
                                                                                                                                                                tables below)
        For 140-150mm Interior Solid Walls
                                                                                                                                                                   CN56X & CN66X & CN99/436
        CN56XA                                                                                      CN56XC
        Standard lengths (mm) 1050-1500 1650-2700                                                    1200 & 1350 1800 & 2100
        SWL (kN)                                  29                 20                                     49                 44
        Weight (kg/m)                            9.0                9.0                                    14.5               14.5
        Nominal height h (mm)                  143                143                                    143                 143
        CN66XC
        Standard lengths (mm) 1650-2700 2850-3300                                     3600            3900-4575               4800
        SWL (kN)                                  54                 47                 39                  29                 26
        Weight (kg/m)                            18.0              18.0                18.0                18.0               18.0
        Nominal height h (mm)                  219                219                219                 219                 219
        CN99/436C
        Standard lengths (mm) 3000-3300 3600-3900                                 4200-4800
        SWL (kN)                                  54                 51                 49
        Weight (kg/m)                            23.0              23.0                23.0
        Nominal height h (mm)                  295                295                295
        Standard lengths are available in increments of 150mm at lengths up to 3000mm, 300mm at lengths from 3000mm  4800mm (including 4575mm, but excluding 4500mm).
        The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
CN5X Lintel supporting first floor partition CN56X Lintel over door opening
           Feature Lintels
           When buildings require a more unconventional
           support solution, Catnic have the expertise to design
           and manufacture special and fabricated lintels to suit
           a variety of shapes and sizes. These include both the
           standard and bespoke fabricated arch lintel ranges
           for the use in more creative openings.
             Catnic - Arches
             When you want to make a feature of brickwork you may
             need more than a standard lintel, so Catnic offers
             both standard and innovative bespoke designs
        Bespoke Designs
        When a building requires a more unconventional support
        solution, Catnic is again, one step ahead and has an
        experienced feature design engineer dedicated to
        providing innovative design solutions to achieve the
        architects vision.
        Although the majority of arches are semi-circular, Catnic     lintels can often be delivered along with standard lintels
        also offer gothic arches for Victorian styled buildings and   minimising delays on site. Each lintel, as always, is
        apex designs for triangular or diamond shaped openings,       manufactured to a high quality standard; hot dip
        curved on-plan for bays, in curved walls and also             galvanised after manufacture to BS EN ISO 1461:1999
        elliptical, parabolic, Arabian and segmental. The list
        is endless and there are limitless variations which           Feature lintels
        Catnic have the capacity to fabricate virtually any           While your imagination runs wild with creative openings,
        arch specification required.                                  why not be inventive with brickwork too? Catnic has the
                                                                      expertise to design and manufacture lintels for decorative
        A fast and cost effective fabrication service from a unique   brick and stone work, for example reduced toe lintels for
        and specialised fabrication facility  means that bespoke     discrete use with cant bricks.
                                                                                                                   B
            Plaster key requirements (internal and external)                                                                   E
                                                                                                               C
                                                                                                                                                            E
               Inner Leaf
                 Dim B       Cavity
                                      Outer Leaf                                                                                        A
                             Dim C                                                                         B
                                                                                                       C                    E
              Typically, end bearings are 200mm
                                                                                                                                                                H
               Dim                            Dim
                B                              C
                                                                                                                                            R
                 Dim C
                                                                                                                                                    D
            Traditional cavity wall      Single leaf support                                                                                                E
            application                  application
D A
                                                                                                               B
           NOTE: As part of Catnics BS EN ISO 9001:2000, manufacture of fabricated lintels will               C                E
           not commence without a signed (approved) copy of our drawing(s) returned to our
           Technical Services Department.
                                                                                                       Apex arch
                                                                                                                                                                H
                                                                                                       B
                                                                                                   C                    E
        Please complete all relevant details and submit to Technical Services on Fax: 029 2086 0135
        If you require further information please Tel: 029 2033 7900
                                                                                                             Date:
        Name:
E-mail: E-mail:
R H H
                                                                                        E               A                    E
                     E                  A                   E
R H H
                                                     D
                                                                                       E                A                    E
                      E                 A                   E
Load per metre (kN) Inner leaf Outer leaf (Please provide full working drawings if unknown)
           Curved Lintel                                         The illustrations shown here are for guidance only.
                                                                 To ensure the lintel design meets the application,
                                                                 the following information will be required:
        Please complete all relevant details and submit to Technical Services on Fax: 029 2086 0135
        If you require further information please Tel: 029 2033 7900
                                                                                                                      Date:
        Name:
E-mail: E-mail:
                                                                                                                                E
                   E                   A                    E
                                                                                                                      A
                                                                                                             R
                                                       E
Note: If submitting this enquiry form, please do not allow for end bearings. This will be calculated by Catnic Technical Services.
Load per metre (kN) Inner leaf Outer leaf (Please provide full working drawings if unknown)
Corner Lintels
Notes:
Support posts
Notes:
        Please complete all relevant details and submit to Technical Services on Fax: 029 2086 A0135
        If you require further information please Tel: 029 2033 7900
                                                                                                                                          Date:
        Name:
        Select required lintel shape - Standard lintels available for mitre, welded corner & bay windows
        Lintel               Wall construction             SWL*           Select          Lintel                  Wall construction                        SWL*          Select
                       Outer Cavity         Inner                                                             Outer Cavity                Inner
        CG50/100           102       65   100-115         26 (kN)                         CG70/125              102        70-85 125-140*                  26 (kN)
        CG50/125           102       65   125-140*        26 (kN)                         CG90/100              102        90-105 100-115                  26 (kN)
        CG70/100           102      70-85 100-115         26 (kN)                         CG90/125              102        90-105 125-140*                 26 (kN)
        *Safe working loads are maximum per leg length for load ratios of 1:1 / 3:1
                                                                                                                                           C
                                                                                                                                          Angle
                                                                    Angle
                           Angle
          A                                     A                                          A
                                                                                                              A                                                         A
B B B
Note: If submitting this enquiry form, please do not allow for end bearings. This will be calculated by Catnic Technical Services.
                                                                                                              CG70/100                                              CG90/100
            Please select Post length required                      A
                                                                                                              CG70/125                                              CG90/125
            1000mm*                       2500mm*
            1500mm*                       3000mm*
            2000mm*                       *Cut to length on site                   Typical details showing 8mm thick base plates bolted to substructure using 12mm diameter fixing bolts
        For Catnic to check suitability of Lintel application, please include the following.
        Plans/Dimensions                  Elevations                    Sections                 Suspended floor layout                               Roof layout
           Accessories
           A range of accessories including ArchCentres,
           Stop Ends, Cavity Weep Vents and Soffit Cladding
           to complement your specific lintel requirements.
ArchCentre Span
                                                                                                                                         ACA - 75mm
                                       Lintel ArchCentre                                                                                 ACB - 150mm
                                                                                      Installation notes
                                                                                      i)   Do not use damaged ArchCentres, refer to ArchCentre
        ArchCentre        ArchCentre             Structural                                Installation Leaflet.
        Code              Span (mm)              Opening (mm)             Rise (mm)
                                                                                      ii) Remove the ArchCentre from its protective wrapping.
        ACA0475           475                    450-500                  75
        ACA0625           625                    600-650                  75
                                                                                      iii) Check that the ArchCentre is correct for application
        ACA0925           925                    900-950                  75               (Refer to the code identification on the underside of
        ACA1050           1050                   1025-1075                75               the arch unit, and to the lintel specification).
        ACA1225           1225                   1200-1250                75
                                                                                      iv) Ensure the ArchCentre and lintel mounting surfaces are
        ACA1350           1350                   1325-1375                75
        ACA1485           1485                   1460-1510                75               clean and dry.
        ACA1625           1625                   1600-1650                75          v) Locate the unit centrally over the opening to determine
        ACA1700           1700                   1675-1725                75               the position on the lintel. The front drip section should
        ACA1785           1785                   1760-1810                75
                                                                                           be trimmed off at the bearing end to allow for thin
        ACB1975*          1975                   1950-2000                150
        ACB2125*          2125                   2100-2150                150              mortar joints and to enhance the appearance.
        ACA2250*          2250                   2225-2275                75          vi) Ensure the lintel is adequately bedded-in at supports,
        ACB2325*          2325                   2300-2350                150
                                                                                           and is parallel to the wall face.
        ACB2425*          2425                   2400-2450                150
                                                                                      vii) Remove the backing from the self-adhesive tape and
                                                                                           locate the unit against the toe of the lintel at a position
        Note
                                                                                           previously determined, and rotate onto the lintel.
        * Incorporate a solid base plate
        Special ArchCentres available - for details please call our Technical         viii) Apply downward pressure to ensure full contact of the
        Services Department on 029 2033 7900                                               self-adhesive tape.
                                                                       Figure 2:
                                                                       Lintel Stop End type C90 for use with CG or CGH lintels and
                                                                       external solid lintels
           Figure 1:
           Lintel Stop End type CL3 for use with combined lintels
           or CL & CU lintels
        Important note
        All external wall lintels fitted with lintel cladding must be
        installed with a flexible damp proof course (DPC) ensuring
        that the DPC projects beyond the front face of the cladding.
                                                                                                              Lintel Product Selector 57
9616 Catnic Lintel Brochure        2/8/06      12:53     Page 58
                                                                                                                      Stirling
                                                                                                          Glasgow                        Dunbar
           Exposure              Approximate wind                                                                    Edinburgh
           zones                 driven rain
                                 (litres/m2 per spell)                                             Ayr
exposure categories.
Quality Assurance
         manufacturer to be awarded                                                   For copies of Catnics BBA Certificates    Clarification and documentation
         a BSI Kitemark licence and                                                   please visit www.Catnic.com or call        of policies and objectives
         BBA certificate.                                                             us on 029 2033 7900
                                                                                                                                 Relating to customers
        BSI Kitemark                                                                                                             requirements to production with a
                                                                                      Technical Conformity
        The Kitemark is a BSI certification                                                                                      view to achieving customer
                                                                                      Catnic comply with the technical
        mark, licensed for use on a product                                                                                      satisfaction
                                                                                      requirement of:
        after independent testing has been
                                                                                       National House-Building Council
        carried out to establish conformity                                                                                      Understanding how statutory and
                                                                                       (NHBC): NHBC is the independent
        with the stated standard, and                                                                                            regulatory requirements impact
                                                                                       regulatory board and the worlds
        satisfactory assessment of the                                                                                           on Catnic and our customers
                                                                                       leading warranty and insurance
        manufacturing control process has
                                                                                       provider for new homes in the UK.
        taken place to establish that such                                                                                       Clear responsibilities and
        conformity may consistently be                                                                                           authorities  increasing motivation
                                                                                       Housing Association Property
        achieved. BSI verifies continuing                                                                                        and commitment
                                                                                       Mutual (HAPM): with appropriate
        product conformity by periodic                                                 adjustment factors lintels are rated
                                                                                                                                 Reduce waste
        product testing and assessment of                                              by HAPM as satisfying the 35 years
        the manufacturing control process.                                             to first maintenance durability          Consistency and traceability of
                                                                                       rating, laid down in the HAPM            products and services
                                                   BRITISH
                                                TO         S
                                                                                       Component Life Manual.
                                    CERTIFIED
                                                           TA
                                                             NDARD
Technical Information
           Research and Development                   The CL & CU lintel range refers to                        Also, because Catnic cavity wall
           The Research, Development and              uniformly distributed loads in the                        lintels are shaped to form a built-
           Technology business of Corus               ratio of 19:1 when non standard or                        in damp proof course, partial fill
           combines top class innovation and          unusual loading conditions occur.                         cavity wall insulation can extend
           cutting edge technology to deliver                                                                   down to the top of the lintel. This
           metals solutions in a constantly         A lintel should not exceed a                              means that the cold voids normally
           changing world.                            maximum vertical deflection of                            associated with separate damp
                                                      0.003 x the effective span (effective                     proof courses are avoided, without
           We use up to the minute technology         span = distance between centre of                         the need to install specially shaped
           to expand and improve the quality          bearings) when subjected to the                           insulation batts behind the DPC.
           of our performance; we continually         safe working load (SWL).
           invest in and upgrade our                                                                            To achieve the thermal benefits of
           manufacturing processes and use            * The brochure SWLs are based on                         a Cougar open back or Classic
           the latest methods in process              the lesser value derived from a                           combined box lintel in accordance
           analysis and design.                       serviceability deflection limitation of                   with the robust details as referred
                                                                                                                in the approved documents: Part L1
           Structural performance                      [   effective span
                                                                325
                                                                            ]   or
                                                                                     [   ultimate failure
                                                                                            1.6 (min)
                                                                                                            ]   and Part L2, the window frame
           The structural data published in the                                                                 should be positioned so that the
           loading tables included in this            Fire tests                                                back face of the frame overlaps the
           technical guide, was achieved in           Catnic lintels have been                                  inner face of the outer leaf of the
           accordance with the requirements           independently tested in accordance                        cavity wall by a minimum of 30mm.
           of BS 5977: Part 2:1983 and BS EN          with the relevant parts of BS476,
           845-2.2003. Extensive testing was          Methods of Determination of the                           The standard range of cavity wall
           undertaken at the following test           Fire Resistance of Loadbearing                            lintels incorporating perforated
           houses:                                    Elements of Construction. Details                         base plates have been designed to
                                                      of the test results can be found                          minimise any potential cold bridge
            The University of Wales, School          in TRADA (Timber Research and                             path without compromising its
             of Engineering                           Development Association) Nos.                             structural integrity. The unique
            The University of Glamorgan,             FR254, 275, 659, 863, 1662 and                            slotted base plate design on the
             Construction Centre                      RF94015 and FROSI (Fire Research                          underside of the lintels provides an
            Ceram Building Technology,               Organisation) No. 5001.                                   effective conductivity not exceeding
             Stoke-on-Trent                                                                                     30W/mK which satisfies the
                                                      Thermal performance                                       requirements of the approved
           Safe working loads (SWL)*, as              All Catnic cavity wall lintels                            document to support Part L1 & L2
           defined by BS 5977: Part 2:1983 for        contribute to the thermal integrity of                    2002 edition.
           cavity wall lintels refer to uniform       the building as they are supplied
           distributed loads applied in the           with an insulated core. The core of
           inner to outer leaf ratios:                the Cougar Open Back style lintels
                                                      is fully filled with CFC & HCFC free
            1:1 For lintels supporting
                                                      insulation to prevent cold voids.
             masonry only
            3:1 For lintels normally carrying
             timber floors
            5:1 For lintels normally carrying
             concrete floors
The Environment
        We consider care for the                     advises on the economic,                All products should be used in
        environment to be essential both             environmental and social                accordance with their specific
        in terms of our duty to society              performance of its products in          instructions to prevent failure.
        and to ensure the continuity of              buildings and structures, in order to
        our business.                                improve sustainability awareness        Handling storage and disposal
                                                     throughout the supply chain.             Gloves should be worn to avoid
        Environmental Policy                                                                   injury from any sharp edges.
        Catnic are committed to protecting           Corus encourage, promote and
        the environment by minimising the            assist in the return of steel for        When lifting or carrying,
        impact of our operations and our             recycling and also actively               consideration must be given to
        products through the adoption of             encourage customers to use                the size and weight of the
        sustainable practices and through            products sustainably. As a result,        product.
        continuous improvement in                    the metals used in construction are
        environmental performance and                now often recycled, as are the           Processes such as welding,
        control. We believe that respect for         metals used in other sectors, such        burning, cutting or grinding can
        the environment is critical to the           as automotive and packaging.              result in vaporising the metal or
        success of our business and our                                                        generating airborne particles that
        aim, therefore, is to continuously           Health & Safety Policy                    may present additional hazards.
        improve our performance.                     Catnic actively work towards Corus
                                                     own international safety rating          Unless required for immediate
        Sustainability                               system and have one of the highest        use on site, all products should
        Corus places great emphasis on the           scores amongst all Corus                  be stored in a clean and dry
        contribution we make to a                    manufacturing sites in the UK.            environment on firm and level
        sustainable society and is                                                             ground.
        committed to incorporating the                We believe that all our activities
        principles of sustainable                     can be undertaken safely and we         Do not use damaged goods.
        development into all aspects of               will never compromise safety.
        our operations.                                                                       When disposing of any Catnic
                                                      We will conduct our business in a       products or packaging, due
        Steel is one of the worlds most              way that ensures the health and          consideration must be given to
        recycled materials with, for                  well being of our employees,             the environmental impact of the
        example, around 40% of the worlds            contractors and any person               method of disposal.
        production of new steel made from           affected by our activities.
        recycled steel. Steel products play
                                                                                             Control of Substances
        a role in everything we do in                 We know that continuous               Hazardous to Health
        modern day life and much of the               improvement of our health and          Regulations 1994 (COSHH)
        steel in use today will therefore be          safety performance is essential for
                                                                                              All products are considered non-
        reused and recycled in the same               a succesful company.
                                                                                               hazardous to health under normal
        and different applications in
                                                                                               conditions of use.
        the future.                                   Everyone in Corus has
                                                      responsibility for their own and
        Corus provides advice to designers
                                                      others' health and safety.
        to help minimise the use of scarce
        natural resources while maximising
                                                      We will encourage a health and
        the potential of low energy,
                                                      safety culture in Corus.
        recyclable products. For example,
        in the construction sector, Corus
           Cougar Open Back Styles                     Classic Combined Box/External              Safe working load (SWL)
           CG and CGH ranges                             Solid Wall/ Internal and Timber            The total uniformly distributed load
           The lintels are manufactured from             Frame Styles                               (UDL) that the lintel is designed to
           galvanised steel to BS EN10327: 2004                                                     support, whilst providing an
                                                         CN and CTF range
           (continuously hot-dip coated strip and                                                   appropriate safety factor.
                                                         The lintels are manufactured from
           sheet of low carbon steels and cold           galvanised steel to BS EN 10327:           Triangulated masonry load
           forming - technical delivery conditions)      2004 (continuously hot-dip coated          A load assessed in accordance with
           of grade DX51D & Z275, but with a             strip and sheet of low carbon steels       the guidelines of BS 5977 Part 1:1981
           minimum yield stress of 250N/mm2.             and cold forming - technical delivery      and AMD 4796:1985
           The lintels are further protected against     conditions) of grade DX51D & Z275
           corrosion by a black coloured polyester       but with a minimum yield stress of         Uniformly Distributed Load (UDL)
           resin coating applied to all external         250N/mm2. The lintels (excluding           A load that is uniformly spread along
           surfaces. The lintels are fully insulated     internal lintels CN92 and CN102) are       the entire length of the lintel.
           with expanded polystyrene bead of             further protected against corrosion by
           density 18kg/m3 giving a thermal                                                         Point load
                                                         a polyester resin coating applied to all
           conductivity of between 0.031W/mK                                                        The load applied from a single
                                                         external surfaces of the lintel. The
           and 0.036W/mK.                                                                           member such as a steel beam or
                                                         lintels are insulated (where applicable)
                                                                                                    girder truss. It should be spread over
           CL & CU range                                 with expanded polystyrene board to
                                                                                                    an appropriate area so that the
           The lintels are manufactured from             BS 3837 Part 1: 2004 (expanded
                                                                                                    limiting design values are not
           galvanised steel to BS EN10327: 2004          polystyrene boards  specification
                                                                                                    exceeded.
           of grade DX51D & Z275 with a                  for boards manufactured from
           minimum yield stress of 250N/mm2.             expandable beads).                         Moment of inertia (Ixx)
           The lintels are further protected             CNZ range                                  Represents the moment of inertia or
           against corrosion by a black coloured         The lintels are manufactured from          second moment of area of the lintel
           polyester resin coating applied to all        galvanised steel to BS EN 10327:           section about a horizontal axis
           external surfaces of the lintels.             2004 (continuously hot-dip coated          through the lintel centroid indicating
                                                         strip and sheet of low carbon steels       the stiffness of a lintel under a given
           The lintels are fully insulated with
                                                         and cold forming - technical delivery      load and indicative of the lintel shape.
           expanded polystyrene board
                                                         conditions) of grade DX51D & Z275          The greater the Ixx level, the stiffer the
           manufactured in accordance with
                                                         but with a minimum yield stress of         lintel will be and hence the less a lintel
           BS 3837: Part 1: 2004 (Expanded
                                                         250N/mm2. The lintels are further          will deflect.
           polystyrene boards specification for
           boards manufactured from                      protected against corrosion by a
                                                                                                    Deflection (  )
           expandable beads). The material is            polyester resin coating applied to all
                                                                                                    Vertical/horizontal displacement of the
           CFC & HCFC free and has an ozone              external surfaces of the lintel.
                                                                                                    lintel due to bending about the
           depletion potential (ODP) of zero.            Feature Lintels                            vertical/horizontal axis.
           The CU range can also be supplied             CCA and CCB range                          Modulus of elasticity (Zxx min)
           with a hot dip galvanised finish after        The lintels are manufactured from          The section Modulus of the lintel
           manufacture to BS EN ISO1461:                 3.0mm structural grade steel plate of      about a horizontal axis, when
           1999. At ordering stage ensure that a         grade S275 to BS EN10025-2:2004            multiplied by the permissible working
           suffix PG is included within the lintel     and hot-dip galvanised after               stress, the resultant value is the
           code reference, ie. CU50/100PG.               manufacture to BS EN ISO1461:1999.         serviceability moment.
           To satisfy the corrosion protection           Glossary
           system of BS 5977: Part 2 and NHBC                                                       Serviceability reaction
                                                         Lintel                                     The permissible load at an end
           technical requirements, lintels
                                                         A structural member spanning an            support within the working load
           galvanised to BSEN ISO1461: 1999
                                                         opening in a wall.                         capacity of the lintel webs.
           must be installed with a separate
           damp proof course.                            Clear span or Clear opening
                                                                                                    End bearing
                                                         The clear distance between
                                                                                                    The bearing length at lintel supports.
                                                         lintel supports.
           62 Lintel Product Selector
9616 Catnic Lintel Brochure         2/8/06   12:54   Page 63
From: Date:
E-mail: E-mail:
        Please indicate whether outer leaf support is required at eaves level                             Yes             No
        Special Requirements (eg. send to Site/Merchant etc.)
EITHER Suspended floor carcass timber OR Suspended concrete floor span directions
Roof carcass (for girder trusses) Structural engineers steelwork arrangements Attic truss carcassing
        NOTE: IT IS IMPORTANT FOR A QUICK TURNAROUND THAT ALL BOXES ARE COMPLETED CORRECTLY BY REFERRING TO THE
        DRAWINGS BEFORE SENDING TO OUR TECHNICAL SERVICES DEPARTMENT
                                                                                                  Lintel Product Selector 63
9616 Catnic Lintel Brochure        2/8/06   12:54   Page 64
Notes
www.catnic.com
        Copyright 2004
        Corus
        Catnic
        Pontypandy Industrial Estate
        Caerphilly
        CF83 3GL
        Telephone 029 2033 7900
        Facsimile 029 2086 7796                                   C03:30000:UK:08/2006