International Journal of Engineering Trends and Technology (IJETT)  Volume-45 Number4 -March 2017
Comparative Study and Analysis of the
Lateral and Vertical Loads Of Pile Foundation
                                         Shashi Kumar1, Harika Priya2
                                        1,2
                                          Department of Civil Engineering
              1,2
                 Lords Institute of Engineering and Technology, Himayathsagar, Hyderabad, India
Abstract Pile foundations are common foundations          summarised the points that need to be amended to
for bridge abutment, piers and buildings resting on       Indian codes of practice to meet the state of the art
soft soil strata. Piles are structural members that are   developments in the subject. Presented in this
made of steel, concrete, or timber. They are used to      research paper are the results of a competetive and
build pile foundations. Despite the cost, the use of      Analysis of Laterally and Vertically Loaded of Pile
piles often is necessary to ensure structural safety.     foundations. compressive clay soil comparasion in
piles are used in construction work, depending on         cohesive soils, cohesiveless soils change parameters
the type of load to be carried, the subsoil conditions,   of pile ( Length) depth in meter considered as
and the location of the water table The objective of      primary parameter. Analysis is performed both for a
the current study is to carry out parametric analysis     single pile and a pile group. It was observed that
of a group of piles by analyzing using finite element     lateral and vertical loaded pile foundation analysis.
method & comparing the results obtained using
empirical equations(Brom s method and Vesics                            II. SOIL INVESTIGATION
method) . The piles are modelled as linear elements.         The overall purposes of this study are to
The effect of soil structure interaction is taken into    investigate the stereography at the site, perform a
account by assuming it as vertical and horizontal         detailed liquefaction susceptibility analysis for the
soil spring (winkler soil spring) . Lateral subgrade      site, and to develop geotechnical recommendations
modulus and vertical subgrade modulus of soil (KH         for design and construction of foundations for the
and kv) is calculated as per is code 2911. The pile       proposed building and associated facilities. Static
group is subjected to both vertical and horizontal        cone penetration tests to get the additional data for
forces.                                                   foundation analysis.
                                                                  Testing selected soil and groundwater
Keywords  Spring Constants, Pile Foundation,             sample in the laboratory to determine pertinent index
Static Analysis, Staad Pro.                               and engineering properties of the soils.
                                                                  analyzing all field and laboratory data in
                  I. INTRODUCTION                         order to develop engineering recommendations for
   Pile foundations are adopted commonly for              foundation design and construction. This reports
various types of multi-storeyed structures when the       presents     our     engineering      analysis      and
founding soil is weak and soft; and also in industrial    recommendations for the entire plant site, including
structures, bridges, offshore structures. With            detailed liquefaction susceptibility analysism
increasing infrastructural growth and seismic             Cohesiveness, soil angle of friction, Density water
activities, designing the pile foundations for load       levels SPT N Values Static Cone Penetration Test:
bearing conditions and soil conditions is of              The static cone penetration is a specialized
considerable importance for the efficient function of     penetration test to obtain a profile of soil resistance
the structures especially, the lifeline structures like   with depth. The test was conducted using our skid
bridges etc. Several studies were conducted by            mounted 10 tones capacity, hydraulically operated.
various researchers on the lateral and verticial          The cone penetrometer used is a mechanical cone
loaded analysis and design of the pile foundations        with friction jacket type that measures the total
and evolved different theories on the same. Codes of      resistance to penetration, cone tip resistance and
practice available in different countries suggested       cone plus friction resistance. The         test     was
some procedures for find lateral and vertical loaded      conducted in general accordance with IS 4968
design of pile foundations. This paper presents a         Part III
short discussion on the various theories evolved on
load calculation pile performance concepts followed       Plate Load Test: Plate load test was performed at the
by outlines of suggested procedures by selected           site at specified depth using a 30 x 30 cm size test
international and Indian codes on the subject. A soil     plate. The test procedure was in general accordance
profile is selected from Gangavaram, Vizag area as        with IS:1888-1982 Test results are presented as a
an exemplary case to demonstrating the load design        graphical plot of bearing pressure on plate are
of pile foundations. From this paper it can be            measured
    ISSN: 2231-5381                       http://www.ijettjournal.org                           Page 153
      International Journal of Engineering Trends and Technology (IJETT)  Volume-45 Number4 -March 2017
Laboratory Tests: The laboratory testing has been             Design of Pile Foundations
carried out in CENGRES laboratory. The quality                The general criteria for the design of pile groups
procedure in our laboratory confirms to IS 2911.          is that:
Soil Classification showing RL and Depth                       The load-carrying capacity of a single pile
                                                              should not be exceeded due to loads and moments
Soil Data                                                     coming from the superstructure.
                                                               The load-carrying capacity of the group should
                                                          not be exceeded by the total superposed loads.
                                                               The settlements, both total and differential,
                                                          should be within permissible limits.
                                                          The design of pile foundation may be carried out in
                                                          the following steps:
                                                                 Calculate the loads. The total load acting on
                                                                    the piles includes the weight of the pile cap
                                                                    and the soil above it. If the ground is newly
                                                                    filled or will be filled in the future, the
                                                                    additional load on piles due to negative skin
                                                                    friction should be included.
Pile Load Test                                                   Get the soil profile of the site and,
Static pile load test is the most reliable means of                 superimpose the outline of the proposed
determining the load capacity of a pile. The test                   foundation and substructure on this. Mark
procedure consists of applying static load to the pile              the ground water level.
in increments up to a designated level of load and               Determine type and length of piles.
recording the vertical deflection of the pile. The load          Determine pile capacity.
is usually transmitted by means of a hydraulic jack              Establish pile spacing
placed between the top of the pile and a beam                    Check stresses in lower strata
supported by tow or more reaction piles. The
vertical deflection of the top of the pile is usually
measured by mechanical gauges attached to a beam,
which span over the test pile
Load Applied to Pile
      Combinations of vertical, horizontal and
         moment loading may be applied at the soil
         surface from the overlying structure for the
         majority of foundations the loads applied to
         the piles are primarily vertical
      For piles in jetties, foundations for bridge
         piers, tall chimneys, and offshore piled
         foundations the lateral resistance is an
         important consideration                          Pile Analysis, Design and Detailing
      The analysis of piles subjected to lateral         For this pile foundation design, piles will be fixed-
         and moment loading is more complex than          head, 0.2m diameter, cast-in-place piles arranged in
         simple vertical loading because of the soil-     pile groups with piles spaced at 0.4m inches center-
         structure interaction. Pile installation will    to-center. The computer program STAAD PRO is
         always cause change of adjacent soil             used to analyze piles for both soil conditions
         properties, sometimes good, sometimes bad        (cohesive, cohesiveless) length of pile 12m, 28m.
                                                          The response to lateral loads is affected to some
                                                          degree by the coincident axial load
    ISSN: 2231-5381                       http://www.ijettjournal.org                           Page 154
      International Journal of Engineering Trends and Technology (IJETT)  Volume-45 Number4 -March 2017
                                                          Equations for determine Pile Capacity
                                                          The ultimate load carrying capacity Qu of a pile is
                                                          given by the equatin Qu = Qp+Qs
                                                          where Qp= load carrying capacity of the pile point,
                                                          Qs = frictional resistance (skin friction) derived from
                                                          the soil pile inter face.
                                                          Point bearing capacity Qp: The Ultimate bearing
                                                          capacity of shallow foundation according to
                                                          terzaghi's equations Qu = 1.3 C Nc + q Nq + 0.4 y B
                                                          Ny
                                                          The general bearing capacity equation for shallow
                                                          foundations for vertical loading qu C Nc + q Nq + y
                                                          B Ny where Nc, nq and Ny are the bearing capacity
                                                          factors the include the necessary shape and depth
                                                          factors
                                                          Qp = C Nc + q Nq now that the term q has been
                                                          replace by q' to signify effective vertical stress. thus
                                                          the point bearing of piles is Qp = Ap qp = Ap ( c' Nc +
                                                          q' Nq) where Ap= Area of pile tip c= cohesion of the
                                                          soil supporting the pile tip, qp = unit point resistance
                                                          q- effective vertical stress at the level of the pile
                                                          The total ultimate load Qu is expressed as the sum of
                                                          these two, that is, Qu = Qb + Qf= qb Ab + fs As
                                                          Utimate friction load
                                                          The load transmitted to the soil along the length of
                                                          the pile is called the Ultimate Friction load or Skin
                                                          load Qf. load transmitted to the base is calld the base
                                                          or point load Qb.. The Total Ultimate Load           is
                                                          expressed as the Sum of Base load and Ultimate
                                                          friction load
                                                                   Qu = Ultimate Friction load (Qf ) + Base
                                                          Point load (Qb)
                                                          Factor of Safety
                                                          The working load for all pile types in all types of
                                                          soil may be taken as equal to the sum of the base
Vertical Load Analysis Of Piles By P-Y Curves             resistance and shaft friction divided by a suitable
The bearing capacity of groups of piles subjected to      factor of safety. A safety factor of 2.5 is normally
vertical or vertical and lateral loads depends upon       used
the behavior of a single pile. The bearing capacity of    Qa = Qb + Qf / 2.5 (Factor of Safety as per IS 2911)
a single pile depends upon size and length pile
parameters. type of soil and the method of pile           General Theory For Ultimate Bearing Capacity
installation. The bearing capacity of a single pile       The total failure load Qu may be written as follows:
increases with an increase in the size and length         Qu = Qu + Wp = Qb + Qf + Wp The general equation
                                                          for the base resistance may be written as Qb = C Nc +
Load Transfer Mechanism                                   qo Nq + 0.5 yd Ny Ab For cohesionless soils, c = 0
The load transfer mechanism from a pile to the soil       and the term cohesive friction becomes insignificant
is complicated. consider pile of length L main factor.    in comparison with the term qoNq for deep
The load on the pile is gradually increased from          foundations Qb = Qu + Wp = q~NqAb + Wp +Qf
Zero point to Q (z=o) at the ground surface, part of
this load will be resisted by the side friction           The net ultimate load in excess of the overburden
developed along the shaft Q1. and part by the soil        pressure load qoAb is
below the tip the pile Q2. A static vertical load is
applied on the top. It is required to determine the
ultimate bearing capacity Qu of the pile. When the
                                                          If we assume, for all practical purposes, Wp and
ultimate load applied on the top of the pile is Qu
                                                          q'oAb are roughly equal for straight side or
                                                          moderately tapered piles
    ISSN: 2231-5381                      http://www.ijettjournal.org                             Page 155
      International Journal of Engineering Trends and Technology (IJETT)  Volume-45 Number4 -March 2017
                                                          analysis of laterally loaded piles such as Equivalent
                                                          Fixity Depth Approach As per IS: 2911-1979
                                                          Vesic has suggested the following for approximating
                                                          ks from the allowable bearing capacity qa based on
Cohesive Soils                                            geotechnical data:
                                                          .
For cohesive soils such as saturated clays (normally      Range of modulus of subgrade reaction ks.
consolidated), we have for </> = 0, N - 1 and N= 0.
The ultimate base load from Eq. (5) is                      Soil                         Ks ( kN/m3)
                                                                      Loose sand         4800-6000
                                                                      Medium dense       9600-80000
                                                                      sand
                                                                      Dense sand         64000-
                                                                                         128000
                                                                      Clayey medium      32000-
                                                                      dense sand         80000
                                                                      Slity medium       24000-
Pile Spacing: The minimum centre-to-centre spacing                    dense sand         48000
of piles is considered from three aspects, namely,                    Clayey soil
practical aspects of installing the piles, diameter of                qa  200 kPa       12000-
the pile, and nature of the load transfer to the soil                                    24000
and
                                                                      200 < qa  800     24000-
possible reduction in the load capacity of piles group.
                                                                      kPa                48000
In case of piles resting on rock, the spacing of two
times the said diameter may be adopted. The spacing                   qa > 800 kPa       >48000
of piles in a group depends upon many factors such
as overlapping of stresses of adjacent piles, cost of
foundation and efficiency of the pile group.
                                                          Soil Spring Constants
Pile Groups In Cohesive Soils:
The effect of driving piles into cohesive soils (clays
and silts) is very different from that of cohesionless
soils. When piles are spaced at closer intervals, the
soil contained between the piles move downward
with the piles and at failure The load-carrying
capacity of a pile groupmay be equal to or less than
the load-carrying capacity of individual piles
multiplied by the number of piles in the group
Ultimate bearing capacity Load Carrying Capacity
of Piles The Ultimate Bearing Capacity Qu of Piles
Qu = As ( 0.5 D y Ny + PD Nq ) + Ki PDi tan i Asi
                                                          Lateral Load Analysis Using Broms Method
      III. LATERAL LOAD ANALYSIS
Laterally Loaded Analysis by Using Subgrade               Analysis of piles using Brom's methods by IS 2911:
Reaction Using Vesics method : A horizontal load          Analysis of a single pile according to Brom's is
on a vertical pile is transmitted to the subsoil          described in Brom's, 1964. This method exclusively
primarily by horizontal subgrade reaction generated       assumes a pile in the homogeneous soil. Thus the
in the upper part of the shaft. A single pile is          analysis method does not allow for layered subsoil.
normally designed to carry load along its axis.           The lateral soil resistance for granular soils and
Transverse load bearing capacity of a single pile         normally consolidated clays which have varying soil
depends on the soil reaction developed and the            modulus is modelled according to the equation
structural capacity of the shaft under bending.
         As per Vesic (1961), modulus of subgrade         Modulus of Subgrade Reaction for Granular Soils,
reaction There are various methods available for          h, in kN/m3
    ISSN: 2231-5381                        http://www.ijettjournal.org                         Page 156
      International Journal of Engineering Trends and Technology (IJETT)  Volume-45 Number4 -March 2017
                                                          less soils pile. showing results with suitable pile
                                                          length and diameter for buidling.
                                                                                REFERENCES
                                                          [1]   Balaam, N.P., Poulos, H.G., and Booker, J.R. (1975).
                                                                "Finite Element Analysis of the Effects of Installation on
                                                                Pile Load-settlement Behaviour," Geot. Eng., Vol. 6, No. 1.
                                                          [2]   Bowles, J.E. (1996). Foundation Analysis and Design,
                                                                McGraw-Hill, New York.Chellis, R.D. (1961). Pile
                                                                Foundations, McGraw Hill, New York. Desai, C.S. (1974).
                                                                "Numerical Design-Analysis for Piles in Sands," J.
                                                                Geotech. Eng. Div., ASCE, Vol. 100, No. GT6.
                                                          [3]   Matlock, H. (1970). "Correlations for Design of Laterally
                                                                Loaded Piles in Soft Clay," Proc. 2nd Offshore Tech. Conf.,
The lateral soil resistance for preloaded clays with            Houston, Vol. 1.
constant soil modulus is modelled according to the        [4]   Matlock, H., and Reese, L.C. (1960). "Generalized
                                                                Solutions for Laterally Loaded Piles," JSMFD,ASCE, Vol.
Broms equation with help of K1 Terzaghis                      86, N. SMS, Part 1.
modulus of subgrade reaction.                             [5]   Matlock, H., and Reese, L.C. (1961). "Foundation Analysis
                                                                of Offshore Supported Structures,"Proc. 5th Int. Conf. SM
From analysis of structure, it is found that maximum            and FE, Vol. 2.
                                                          [6]   Meyerhof, G.G. (1951). "The Ultimate Bearing Capacity of
axial load in working condition is 2932 kN. Pile                Foundation," Geotechnique, Vol. 2,No. 4.
capacity is checked for above value of axial load         [7]   Murthy, V.N.S, and Subba Rao, K.S. (1995). "Prediction of
required to be transmitted. Bearing capacity of piles           Nonlinear Behaviour of LaterallyLoaded Long Piles,"
is calculated as per procedure given in Appendix B              Foundation Engineer, Vol. 1, No. 2, New Delhi.
                                                          [8]   Poulos, H.G. (1974). Elastic Solutions for Soil and Rock
IS: 2911-1979 part 1/sec 2                                      Mechanics, John Wiley & Sons, NewYork. Poulos, H.G.,
Ultimate Skin Resistance Qs = (*C +                            and Davis, E.H. (1980). Pile Foundation Analysis and
K*Pdi*tan)*Asi                                                 Design, John Wiley & Sons,New York
Ultimate End Bearing Capacity Qb = (Cp*Nc +
Pd*Nq + 0.5**B*N)*Ap
Ultimate Bearing Capacity Of Soil Qu = Qs + Qb-W
       IV COMPARISION & CONCLUSION
The analytical methods like Broms presented almost
half a century back still holds good in estimating the
pile head deflections under the lateral loads. Even
though these methods overestimate the deflection,
they can still be adopted considering the soil as a
complex and nonlinear material which is influenced
by many variables, including its history, nature of
loading, changes in the environment, method of pile
installation etc. Broms methods which gave fairly
accurate results can be adopted for small scale
projects and when softwares are not available for the
analysis. The STAAD Pro analysis, though
applicable for structural analysis and design, can be
effectively used to evaluate pile head deflections
with some multiplication factor due to its
consistently lower deflection values. Its dependence
on soil spring constants and ultimately on the
accuracy in the estimation of soil elastic modulus
based on soil properties and field data shall be well
understood before its use. Comparision between
Cohesive Soils, Cohesiveless Soils Behaviour of
piles Single pile lateral and verticial load bearing
capacity and group of piles. Obtain Various Pile
Parameters (Length) Ground Level soil behavior.
Calculating efficiency of the pile Subjected to lateral
loads. Calculating Bending moment, shear forces,
deflection and response of Piles. Conclude with
effeciency Pile length soil spring constant suitable
for site. While comparing Pile length on cohesivess
    ISSN: 2231-5381                       http://www.ijettjournal.org                                  Page 157