0% found this document useful (0 votes)
211 views4 pages

Lazy Axe Access Print Commands Guide

This document provides print commands for accessing data from different network elements in the LAZY AXE ACCESS 910 PRINT system. It includes commands for the STC, RPG, GSD, ETC, AUS (EMG), and TAU network elements. The commands allow viewing data on resource points, equipment, connections between devices, software loads, hardware information, and status of the different elements.

Uploaded by

n70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
211 views4 pages

Lazy Axe Access Print Commands Guide

This document provides print commands for accessing data from different network elements in the LAZY AXE ACCESS 910 PRINT system. It includes commands for the STC, RPG, GSD, ETC, AUS (EMG), and TAU network elements. The commands allow viewing data on resource points, equipment, connections between devices, software loads, hardware information, and status of the different elements.

Uploaded by

n70
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

LAZY AXE ACCESS 910 PRINT COMMANDS

Issue 4 (Local 7.2 and TL 4.2)

STC

DIRRP:RP=rp or ALL; RP & EM Events.


STC EXEMP:RP=rp,EM=em or ALL; EM data.
EXCLP:EQM=ALL; Control Signalling Link data.
EXCLP:EQM=CLC-x; Control Signalling Link data.
EXEGP:EMG=emg or ALL; EMG Control signalling link device.
EXRPP:RP=rp or ALL; RP data.

STC-M RPG Connected.

RPG DIRRP:RP=rp or ALL; RP & EM Events.


EXEMP:RP=rp,EM=em or ALL; EM data
EXCGP:DEV=CSLDEV-x; or ALL; GS connected CLC Device
EXCPP:EMG=emg or ALL[,RDL]; GS connected CLCs,
EXCPP:EQM=ALL[,RDL]; RDL = Redundancy Level
EXCPP:EQM=CSLM7-x[,RDL]; As above.
EXEGP:EMG=emg or ALL; EMG Control signalling link device.
EXRPP:RP=rp or ALL; RP data
Device and GS connection.

RPG for V5.1 AU(Pots,BA),TAU Both AU & TAU require individual RPGs
RPG
DIRRP:RP=rp or ALL; RP & EM Events.
EXDRP:DEV=STAU-x or STTAU-x; Used to locate connected RPG.
EXEMP:RP=rp,EM=em or ALL; EM data
EXRPP:RP=rp or ALL; RP data
GNACP:AG=ag or ALL; GAM Data Connection.
GNACP:CONCG=concg or ALL; Connected to concentration group
GNACP:DIP=dip; AG connection.
GNSPP:DIP=xLIAU or xLITAU; GAM Signalling Channel Path
GNSPP:SNT=ALL; GAM Signalling Channel Path
GNSPP:SNT=STAU-x or STTAU-x; GAM Signalling Channel Path
GNSTI:SNT=STAU-x or STTAU-x; Transfer NT to another free RPG.
NTCOP:SNT=STAU-x or STTAU-x; Device and GS connection.
GSD GSD Multiple positions & connected devices.

EXMDP:MUP=mup; (eg GS-3-10) Multiple position and Device connections


NTCOP:SNT= ETRST-x or ALL; Shows DIP and Device connections.
NTCOP:SNTP=sntp or ALL; As above. (Eg. SNTP=TSM-2-4&&-7)
NTSTP:SNT=ETRST-x or ALL; Shows SNT status.

ETC4 RST devices


ETC
EXDRP:DEV=RST-x; Shows ETC connected RP / EM & route.
EXDEP:DEV=RST-x Shows SNT and EMG route.
DTDIP:DIP=xETRST; Connected SNT.
DTIDP:DIP=dip or ALL: DIP initial data.
DTSTP:DIP=xETRST; DIP status.
STDEP:DEV=RST-x; RST device status.

Robert Walker, EGS Australia, Phone ECN 880 4606. 31/08/17 Page 1
AUS (Equivalent to EMG EM)

DIREP:EMG=emg or ALL; EMG Event Record.


EXEDP:EMG=emg,EM=em; Shows loaded software.
EXEGP:EMG=emg or ALL; EMG Control signalling link device.
EXEIP:EMG=emg,EM=em or ALL; EMRP Information, EMRP type.
EXEPP:EMG=ALL,EM=ALL; EMG EM Processor Control State.
EXEPP:EMG=emg,EM=em or ALL; As above.
EXHWP:MACCG=emg; All hardware information.
EXHWP:PIU=AUS-x; As above.
AUS EXMCP; Multiple Access Groups to EMGs
(EMG) EXPUP:MACCG=emg[,SR=sr Position, subrack and states of PIU.
[MACCG] [,POS=pos...]];
EXPUP:PIU=AUS-x or AUEP-x; As above.
EXSMP:ENB=ALL,ANL,EMG=emg; Emergency lines & Announcement lines.
EXSMP:ENB=ALL,ANL; As above.
NNBLE:NODE=AUS-x; Deblock AUS.
NNBLI:NODE=AUS-x; Block AUS.
NNCDP:MACCG=emg; Network nodes characteristics (Clock).
NNCDP:NODE=AUS-x or ALL; As above.
NNCOP:MACCG=emg; Shows AUS hardware variant.
NNCOP:NODE=AUS-x or ALL; As above.
NNIDP:MACCG=emg; Shows Node Mesh & AUS status.
NNIDP:NODE=AUS-x[&&-x]; As above.
NNSTP:MACCG=emg; Shows Node State.
NNSTP:NODE=AUS-x [,LIST]; As above.
NNSTP:NODE=AUS-ALL; As above.
NNTEI:NODE=AUS-x; Initiates testing the AUS.
NNUPP:MACCG=emg; Shows connected Devices/DIPs to Ports
NNUPP:NODE=AUS-x[&&-x]; As above.
NNUPP:NODE=AUS-x As above.
[,PORT=port];
PWESP:MACCG=emg(,SWITCHED); Protection switching equipment state.
(SWITCH only PIUs with protected
switching will be printed)
PWSCC:PIU=piu...,AUTO=auto Automatic protection switching (Yes/No).
[,LIM=lim]; (1-100) Set percentage of faulty devices on a
PWSCC:PIUTYPE=AUS[,AUTO=aut] board before a automatic switch is done.
[,LIM=lim]; (1-100)
PWSCP:PIU=AUS-x; Protection switching equipment criteria.
PWSCP:PIUTYPE=AUS; Protection switching for type AUS.
RECEI:EMG=emg,EMRP=x-A; Repair EMRP.
RECEI:EMG=emg,STR=A or B; Repair STR.
REMEI:EMG=emg,MAG=EM-x, Maintenance Block EMRP.
PCB=EMRPI;
REMEI:EMG=emg,MAG=STR-A/B, Maintenance Block STR.
PCB=EMRPI;
REPEI:EMG=emg,EMRP=x-A; Fault Repair EMRP.
REPEI:EMG=emg,STR=A or B; Fault Repair STR.
SYESI:EMG=emg,EM=em or ALL, Restart with or without Reload
EMRPRANK=RELOAD; Use MINRQ or COMPL or RELOAD

Robert Walker, EGS Australia, Phone ECN 880 4606. 31/08/17 Page 2
TAU(Equivalent = SLCT +more)

BLPFI:PIU=TAU-x Forced TAU blocking.


BLPUI:PIU=TAU-x; Block TAU. Need to block DIP first.
BLPUE:PIU=TAU-x; Deblock TAU.
TAU DTSTP:DIP=xLITAU; DIP status.
EXHWP:PIU=TAU-x; TAU hardware information.
EXPCP:PIU=TAU-x[&&-x]; Shows Device and DIP connection.
EXPUP:MACCG=emg; Shows TAU to AU communication status.
Shows status of specific position in a
EXPUP:MACCG=emg,SR=sr, subrack.
POS=pos..; As above.
EXPUP:PIU=TAU-x[&&-x]; Shows TAU sub rack connection.
Test
Bus
EXTCP:MACCG=emg; Change TAU connection to sub rack.
EXTGC:PIU=piu,SR=sr; Shows TAU connected to sub rack.
EXTGP:MACCG=emg,SR=sr; Shows the sub rack TAU located in.
EXTGP:PIU=TAU-x; Shows what software is loaded.
FCLPP:PIU=TAU-x,[LOADED]; As above.
FCLPP:SUID=suid,MACCG=emg; Shows current phase and status.
FCPUP; Test System access to Debugger.
TEPUI:PIU=TAU-x;

AU For both POTs & BA.

BLPFI:PIU=AU-x; Forced AU blocking.


BLPUI:PIU=AU-x; Block AU. Need to block DIP first.
BLPUE:PIU=AU-x; Deblock AU.
DTSTP:DIP=xLIAU; DIP status.
EXHWP:PIU=AU-x; AU hardware information.
EXPCP:PIU=AU-x[&&-x]; Shows Device and DIP connection.
EXPUP:MACCG=emg; Shows TAU to AU communication status.
EXPUP:PIU=AU-x[&&-x]; Shows what software is loaded.
FCLPP:PIU=AU-x; Subscriber line circuit test.
SLOCI:PIU=AU-x; As above.
SLOCI:SNB=snb; As above.
AU SLOCI:DEV=dev; Test subscriber line.
SLOMI:DEV=dev,MP=11; As above.
SLOMI:SNB=snb,MP=11; To finish SLOMI command.
:END; Test System access to Debugger.
TEPUI:PIU=AU-x; Var SYSTMANSTATE contains V5.1
PRINT VAR CTRLAU 0-:57; Interface state.
HF = Null means not started
H0 = Starting Up.
H4 = Working. See Plex for other states

Robert Walker, EGS Australia, Phone ECN 880 4606. 31/08/17 Page 3
AUS LED FUNCTION

AUS PIU

MIA Red Manual Intervention Allowed OAM

PWR Green Power OK. On = Stable power source.

On = Active control signalling link


COM Green Communication protocol OK.
protocol towards APZ.

SYN Yellow Clock Synchronisation On = Proper synchronisation


Flash = 1 synch ring missing.

CSR Yellow Call Set up Rate Flash One flash = A call is set up in
the time switch.

TL1 Yellow Traffic Level 1 indication TL1 off + TL2 off = no traffic.
TL1 on + TL2 off = 0<X<100

TL2 Yellow Traffic Level 2 indication TL1 off + TL2 on = 100<X<200


TL1 on + TL2 on = 200< calls