0% found this document useful (0 votes)
185 views2 pages

Bid Eeea300a

This document provides bid specifications for a flexible gas analyzer system including a 5-gas analyzer module, handheld PC, software, and accessories. The key specifications of the analyzer module are listed, including gas measurement ranges and accuracies. Features of the handheld PC and software are described. The document also lists optional configuration models, accessories, and safety information.

Uploaded by

Balaam1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
185 views2 pages

Bid Eeea300a

This document provides bid specifications for a flexible gas analyzer system including a 5-gas analyzer module, handheld PC, software, and accessories. The key specifications of the analyzer module are listed, including gas measurement ranges and accuracies. Features of the handheld PC and software are described. The document also lists optional configuration models, accessories, and safety information.

Uploaded by

Balaam1
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Flexible Gas Analyzer (FGA)

5-Gas Analyzer
BID SPECIFICATIONS
Performance Ranges/Resolutions:
HC: 0 - 30,000 ppm @+/-3% accuracy, 1 ppm resolution
CO: 0 -15% +/-3% accuracy, .01% resolution
CO2: 0 - 20% +/-3% relative, .01% resolution
O2: 0 - 25% +/-5% relative, .01% resolution
NO: 0 - 5000 ppm +/-4% relative 1 ppm resolution
Operating Temperature Range:
32 to 122 F. (0 to 50C)
Relative Humidity: up to 90%, non-condensing
Storage Temperature Range:
-4 to 158 F. (-20 to 70C)
Relative Humidity: up to 90%, non-condensing
Response Time: 90% of full scale in 8 seconds
Warm-up Time: 1 minute
FEATURES Flow Rate: 7.0 liters per minute
Flexible design and versatile software options allow for use with
multiple display devices: FGA HANDHELD PC
- pocket PC Display: 2.5 x 3.25, 320 x 420 color; detachable for viewing at
- laptop or desktop PC any angle
- MODIS platform
Display Control: Touch screen with stylus pen
Lightweight, go anywhere portability, powered by:
Expansion: open architecture and compact flash slot accept
- Long-life internal battery rechargeable with standard
peripheral devices (modem, bar code reader, etc.) designed for
wall charger or vehicle battery handheld PC
- 12VDC source with cigarette lighter adapter external External Ports: 1 RS232; 1 compact flash slot; 1 infrared port
- 12VDC direct from vehicle battery Compact, one-hand operation
Meets or exceeds BAR 97 and European OIML Class 0
Advanced Windows CE operating software
standards for accuracy
Print capability via infrared port

FGA GAS MODULE 6V DC power maximum

Model EEEA300A Audio-capable


Included with Model EEEA301A
Non-dispersive infrared gas bench (Specific model may vary depending on availability)
Heavy-duty sampling system with dual head sample pump
20 sample hose with self-retaining sample probe SOFTWARE
Optional 12 RPM and oil temperature probes Live Gas Display: displays all five gases simultaneously, or
RS232 serial and USB communications ports individually, plus AFR, Lambda or GPM readings
PDA power port for handheld PC, 6V DC maximum Data Display Options: gas digital, gas graph, custom gas, X/Y
plotting, min/max, optional RPM/oil temperature
Long-life rechargeable internal battery
Easily replaceable NO and 02 cells Pass/fail limits

Power: 12VDC Catalytic converter test

Dimensions: 14 x 9 x 8 Save/recall test data with shop and vehicle ID

Weight: 10 lbs. Model EEEA300ASW PC software package


Model EEEA301ASW flash card software package
Model EEEA306A01 MODIS Software
BID SPECS CONT.

MODEL CONFIGURATIONS

Model EEEA300A: includes FGA module, hoses, probes, power


accessories, power supply, RS232 cable. (Requires
EEEA300ASW, EEEA301ASW or EEMS306A01).
Model EEEA301A: includes FGA module, pocket PC, hoses,
probes, flash card, power accessories, power supply, RS232
cable
Model EEEA300ASW: PC software package only ( Requires
EEEA300A & PC w/Windows 98/2000/XP)
Model EEEA301ASW: Flash card software package only
(Requires EEEA300A & pocket PC w/Windows CE 3.0 or later)
Model EEMS306A01: MODIS software package only (requires
EEEA300A)

OPTIONAL ACCESSORIES

EAK0213L10A RPM Kit: includes adapters for connection to


spark plug wire, OBD II port, or radio frequency (RF)
EAK0213L11A Gas Calibration Kit: includes adapters, hoses
and gauge. Calibration gas not included
EAK0213L12A Oil Temperature Kit: includes 12 temperature
probe. Requires EAK0213L10A RPM kit.

SAFETY INFORMATION
Products may have inherent risk to the user.
Read, understand and follow all safety messages on
the product, user manual and vehicle to be serviced
before operating Model EEEA300A.
Improper use may result in injury

Specifications subject to change without notice.

SS2102 (10/2002) 2002 Snap-on Tools Company