Absolute Quality Certification ‘AQC JORDAN [An ISO Certification Body) RUM CODE (0421638821017 Calibration Report Report NO. : (RPTC-3852-2017) ‘Company Name: J) 335) Jil pad Ga yi pS, S Address: Amman Jordan Tel: 00962 6 778405660107 78405669 Fax: NA E-mail: marmouti@fait.cpm.io Tquipment] Instrument information Tnstrument Name: Compostable Gas Indicator Manufacturer: Gas Cope Model / Type: 625, S/N: 10950 Description : Compostable Gas Indicator Location : Customer Site Customer ID: V/A sl TRSFECHONNOTES, “Test Performed: Gas Equipment Statues: B Good a Defected Other (specify) Calibration Date: 24/10/2017 Calibration Due Date: 24/10/2018 Calibration Conditions: ‘Temperature: (20.5 °C) Relative Humidity: 39.0 RH %) TECHNICAL DATA Calibration Location: | RUM Lab Calibration Method No. (SOP) Manufacturer | errective ate: specification U Range: 070 100% Acceptable Toleranc WA Test Point jag | Unit Under Test Reading Dblistione Reference Reading (LEL%) Correction 596 concentration - 100 ‘Correction = Reference Reading ~ Unit under Test Reading i Standard Used: Description Type/Model_| Serial No, | Calibration Date | Calibration Due Date Gare Metiane 5007 grag | asmzasns | aaooaor | aonaoie The above instruments have been cllorated using instruments Waceable to International standards FINALRESULT, Pass FAIL The result concem only the objects specified in this report. ‘Remarks: The Compostable gas indicator calibration should read 100% on the meter " MM M erry Ri saas Calibrated By wecked By jroved BY OA/OC Cal, & Q. Engineer Technical Manager “Qualify Manager ‘Murshed ALDiri Husam Yjamdan Huda Shaliey_, or Be a ee PyINTAG Zr Oh [AlFubels- Queen Rania Street beside Baccalaureate Schools Te: +962 64722500 Mobile: +962 79 7443308 —Fax: 962 6 4722505 Email: customercare@®rumeal.com / Websiteworw.rumeal.com Prepared By: Lama AlReyahi For-To16 Revs. Page oft

You might also like