Calculations:
Flow rate (Qv):
Q=V/t
Q1=0.005/25=2*10e-4
Q2=0.005/25=2*10e-4
Similarly others.
Torque (T):
T= (w1-w2)*r
T1= (2-1)*0.03=0.03
T2= (2.5-1.5)*0.03=0.037                n2=r1*n1/r2
Similarly others.                        n2= 33*2300/60=1265
Brake power (Pb):                        similarly for other rpms
Pb= 2nT/60
Pb1= 2*1265*0.03/60=3.97
Pb2=2*1375*0.037/60=5.4
Water Power (Pw):
Pw=
Pw1=1000*9.8*8*2*10e-4=15.7
Pw2=1000*9.8*8*2*10e-4=15.7
Similarly others.
Overall efficiency ():
=Pb/Pw
1=3.97/15.7=25.31%
2 =5.4/15.7=34.9%        similarly others.
Calculations:
Flow rate (Qv):
Q=V/t
Q1=0.005/13.75=3.6*10e-4
Q2=0.005/16=3.1*10e-4
Similarly others.
Torque (T):
T= (w1-w2)                            n2=r1*n1/r2
T1= (1.75-1)*0.03=0.0225              n2= 33*2200/60=1210
T2= (1.75-1)*0.03=0.0225              similarly for other rpms
Similarly others.
Brake power (Pb):
Pb= 2nT/60
Pb1= 2*1210*0.03/60=2.85
Pb2=2*1265*0.037/60=2.98
Water Power (Pw):
Pw=
Pw1=1000*9.8*2*3.6*10e-4=7.06
Pw2=1000*9.8*3*3.1*10e-4=9.12
Similarly others.
Overall efficiency ():
=Pb/Pw
1=2.85/7.06=40.37%
2 =2.98/9.12=32.67%        similarly others.