FDD Reporting Events
Intra-frequency reporting events: 1A…1J Traffic volume reporting events: 4A and 4B
1A: A primary CPICH enters the reporting range 4A: Transport Channel Traffic Volume exceeds an absolute threshold
1B: A primary CPICH leaves the reporting range 4B: Transport Channel Traffic Volume becomes smaller than an absolute
1C: A non-active primary CPICH becomes better than an active primary threshold
CPICH
1D: Change of best cell
1E: A primary CPICH becomes better than an absolute threshold
Quality reporting events: 5A
1F: A primary CPICH becomes worse than an absolute threshold
5A: A predefined number of bad CRCs is exceeded
1J: A non-active E-DCH but active DCH primary CPICH becomes better
than an active E-DCH primary CPICH
UE internal measurement reporting events: 6A…6G
Inter-frequency reporting events: 2A…2F 6A: The UE Tx power becomes larger than an absolute threshold
2A: Change of best frequency 6B: The UE Tx power becomes less than an absolute threshold
2B: The estimated quality of the currently used frequency is below a 6C: The UE Tx power reaches its minimum value
certain threshold and the estimated quality of a non-used frequency 6D: The UE Tx power reaches its maximum value
is above a certain threshold 6E: The UE RSSI reaches the UE’s dynamic receiver range
2C: The estimated quality of a non-used frequency is above a certain 6F: The UE Rx-Tx time difference for a RL in the active set becomes
threshold larger than an absolute threshold
2D: The estimated quality of the currently used frequency is below a 6G: The UE Rx-Tx time difference for a RL in the active set becomes less
certain threshold than an absolute threshold
2E: The estimated quality of a non-used frequency is below a certain
threshold
2F: The estimated quality of the currently used frequency is above a
certain threshold UE positioning reporting events: 7A…7D
7A: The UE position changes more than an absolute threshold
7B: SFN-SFN measurement changes more than an absolute threshold
Inter-RAT reporting events: 3A…3D 7C: GPS time and SFN time has drifted apart more than an absolute
3A: The estimated quality of the currently used UTRAN frequency is below threshold
a certain threshold and the estimated quality of the other system is 7D: GANSS time and SFN time have drifted apart more than an absolute
above a certain threshold. threshold
3B: The estimated quality of other system is below a certain threshold
3C: The estimated quality of other system is above a certain threshold
3D: Change of best cell in other system
Source: 25.331, ver. 9.1.0