Analysis & Design of Combined Footing: Condition:1

The document analyzes and designs a combined footing to support two columns. STAAD analysis of the column loads results in maximum forces and moments. Sizing checks confirm the required footing area and reinforcement are adequate to resist the loads with safety factors applied. The footing geometry and reinforcement details are designed and specified.

Uploaded by

Nikhil Poriya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
172 views3 pages

Analysis & Design of Combined Footing: Condition:1

The document analyzes and designs a combined footing to support two columns. STAAD analysis of the column loads results in maximum forces and moments. Sizing checks confirm the required footing area and reinforcement are adequate to resist the loads with safety factors applied. The footing geometry and reinforcement details are designed and specified.

Uploaded by

Nikhil Poriya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ANALYSIS & DESIGN OF COMBINED FOOTING

INPUT DATA : INPUT COMBINED FOOTING: CF1


fck = M 30
fy = Fe 415 CONDITION
2
SBC = 140 kN/m C5 1
Column Geometry:
C/C distance between Col's : 2.07 m
Column id: C5 C6 : LOAD CASES :
Lx = 300 375 mm X
Lz = 450 300 mm Lz
Offset from face of column : 75 mm Z

CONDITION:1

C6

C5 C6 Lz

Lx

Lx CONDITION: 2

:STAAD RESULTS : :TOTAL OF TWO COLUMNS:


Force-X Force-Y Force-Z Moment- Moment- Moment- Force-X Force-Y Force-Z Moment- Moment-Y Moment-
Node L/C
kN kN kN X kNm Y kNm Z kNm kN kN kN X kNm kNm Z kNm
C5 / 2005 5 1.652 390.714 -3.316 -2.225 0.274 -1.693 4.97 982.56 -4.49 -3.27 0.14 -4.99
6 -25.432 174.024 0.584 5.806 1.428 45.888 -59.77 772.12 0.09 6.08 2.35 106.58
7 28.325 549.132 -7.136 -10.473 -1.002 -48.87 68.35 991.39 -8.44 -12.27 -2.16 -115.25
8 0.699 430.239 -38.46 -76.252 0.357 -0.774 2.36 839.58 -58.00 -110.06 0.13 -2.49
9 2.194 292.917 31.909 71.585 0.069 -2.209 6.23 923.94 49.66 103.88 0.06 -6.18
10 -20.181 162.528 0.435 4.731 1.191 36.549 -47.28 698.34 -0.18 4.73 1.91 84.74
11 22.825 462.614 -5.741 -8.292 -0.752 -39.257 55.22 873.75 -7.00 -9.96 -1.69 -92.72
12 0.724 367.5 -30.801 -60.915 0.335 -0.78 2.43 752.30 -46.66 -88.19 0.14 -2.51
13 1.92 257.643 25.495 57.354 0.105 -1.928 5.52 819.79 39.48 82.96 0.08 -5.47
14 -26.011 29.393 1.895 6.739 1.343 46.484 -61.49 419.42 1.76 7.32 2.31 108.32
15 27.747 404.5 -5.826 -9.539 -1.087 -48.274 66.64 638.69 -6.77 -11.03 -2.20 -113.52
16 0.121 285.607 -37.15 -75.318 0.272 -0.177 0.64 486.87 -56.34 -108.83 0.10 -0.75
17 1.615 148.286 33.219 72.518 -0.016 -1.612 4.51 571.23 51.33 105.11 0.02 -4.45
C6 / 2006 5 3.314 591.844 -1.169 -1.041 -0.135 -3.295
6 -34.335 598.099 -0.49 0.277 0.922 60.696 Distance of Load C.G. from column C5 : 1.247 m
7 40.029 442.26 -1.302 -1.797 -1.157 -66.382 Area of Footing Required: 5.721 m2
8 1.659 409.338 -19.544 -33.812 -0.224 -1.713
9 4.035 631.02 17.752 32.291 -0.011 -3.972 Footing Geometry :
10 -27.095 535.811 -0.611 -0.004 0.723 48.195 Length of the footing Lx = 3.65 m
11 32.397 411.14 -1.26 -1.663 -0.94 -53.467 Width of the footing Lz = 1.8 m
12 1.701 384.803 -15.854 -27.275 -0.194 -1.732 Area of footing Provided = 6.57 m2
13 3.602 562.148 13.983 25.608 -0.023 -3.54 O.K.
3
14 -35.474 390.027 -0.132 0.581 0.969 61.833 Zxx = 1.971 m
3
15 38.89 234.188 -0.943 -1.493 -1.11 -65.245 Zzz = 3.997 m
16 0.52 201.267 -19.186 -33.508 -0.177 -0.576
17 2.896 422.948 18.111 32.596 0.036 -2.835
: SIZING CHECK :
Minimum width of
L/C Factor Req. Area P/A MX/ZX Mz/Zz P(max) P(min) P(allow) REMARKS
beam (req.) : 600. mm
5 1.5 5.15 109.67 -1.10 -0.83 111.61 107.73 140 O.K. O.K. So,
6 1.5 4.04 86.18 2.06 17.78 106.02 66.35 175 O.K. O.K.
7 1.5 5.19 110.66 -4.15 -19.22 134.03 87.28 175 O.K. O.K. Width of beam (prov.) : 600. mm
8 1.5 4.40 93.71 -37.23 -0.41 131.35 56.07 175 O.K. O.K.
9 1.5 4.84 103.13 35.13 -1.03 139.29 66.96 175 O.K. O.K. For, Slab Design :
10 1.2 4.57 97.43 2.00 17.67 117.10 77.77 175 O.K. O.K. P(max) : 166.76 kN/m2
11 1.2 5.72 121.91 -4.21 -19.33 145.45 98.37 175 O.K. O.K.
12 1.2 4.93 104.96 -37.29 -0.52 142.77 67.15 175 O.K. O.K. For, Beam Design :
13 1.2 5.37 114.38 35.08 -1.14 150.60 78.16 175 O.K. O.K. P(max) : 150.37 kN/m2
14 0.9 3.66 78.03 4.13 30.11 112.26 43.79 175 O.K. O.K. ( Considering Moment
15 0.9 5.58 118.82 -6.22 -31.56 156.59 81.04 175 O.K. O.K. along X-X axis only .)
16 0.9 4.25 90.57 -61.35 -0.21 152.13 29.02 175 O.K. O.K.
17 0.9 4.99 106.27 59.26 -1.24 166.76 45.77 175 O.K. O.K.
0.578 m 2.070 m 1.002 m

0.600 m 1.247 m 0.823 m

C5 C6 1.800 m

0.600 m

3.650 m COMBINED FOOTING: CF1


SLAB DESIGN :
Clear cantilever for slab : 0.600 m fck = M 30 Effective Depth required : 104.37 mm
Maximum Pressure @ base : 166.76 kN/m2 fy = Fe 415 Total depth required : 159.37 mm
So, Moment @ base : 30.02 kNm kmax = 0.479 So, Provide Total depth : 300 mm
Shear @ base : 50.03 kN Rmax = 0.138 Depth @ Edge : 150 mm
Factored Moment : 45.025 kNm *Dia. of bar : 10. mm Effective Depth Provided : 245 mm
Factored Shear : 75.042 kN *Clear cover : 50. mm pt required : 0.214 %
So, Ast Required : 524.81 mm2 β: 13.582 Min. pt required : 0.120 %
Provide, (*Assumed)
Dia. 10 @ 125 mm C/C Check for Shear : Acting shear stress: 0.306 N/mm2
( Ast(prov.) : 628.32 ) O.K Permissible Shear stress: 0.373 N/mm2 O.K

BEAM DESIGN :
589.29 892.65 Max. base pressure ( Pb ) = 150.37 kN/m2
UDL acting on the beam = Pb x w = 270.67 kN/m
Factored UDL (1.5X )= 406.01 kN/m

406.01 kN/m Width of beam provided = 600.00 mm


485.88 Effective depth required = 286.65 mm
234.73 Total Depth required = 374.65 mm
X = 0.873
Total Depth provided = 600.00 mm
0 0
: TOP REINFORCEMENT :
-406.77 Max. Moment = 86.97 kNm
-354.56 Effective depth provided = 559.00 mm
S.F.D. pt required : 0.131 % (assuming 25mm cover @ top)
86.97 Min. pt required : 0.205 %
So, Ast Required : 737.35 mm2
Provide,
5 Nos. - 16 Dia.
+
0 Nos. - 0 Dia.
( Ast(prov.) : 1005.31 ) O.K ( Pt(prov.): 0.300 % )

67.85 203.76 : BOTTOM REINFORCEMENT :


B.M.D. Max. Moment = 203.76 kNm
(where, X is the point of contarflexure) Effective depth provided = 512.00 mm
pt required : 0.379 %
Min. pt required : 0.205 %
So, Ast Required : 1163.81 mm2
Provide,
5 Nos. - 20 Dia.
+
0 Nos. - 0 Dia.
( Ast(prov.) : 1570.80 ) O.K ( Pt(prov.): 0.511 % )

: SHEAR REINFORCEMENT :
Maximum shear force = 485.88 kN
Max. Shear stress = 1.582 N/mm2 β: 6.812
Permissible Shear stress = 0.501 N/mm2
Section needs to be design for shear reinforcement.
Design shear force = 331.86 kN
Provide,
Nos. of Legs : 4 Dia of Stirrup ring = 8 mm
Spacing required : 112.00 mm
Spacing provided : 100 mm O.K
: SIDE FACE REINFORCEMENT : (Cl.26.5.1.3.; IS 456-2000)
Required total Ast : 0 mm2 ( Ast(prov.) : 0.00 )
Provide, 0 Nos. - 0 Dia. O.K