PC580 v2.3 Installation Manual
PC580 v2.3 Installation Manual
This manual contains information on limitations regarding product use and function and information on the
        limitations as to liability of the manufacturer. The entire manual should be carefully read.
This panel will not operate if installed outside of North America. See section 1.1 for details.
                               Installation
                                 Manual
                                                                                                                                                                                                        i
     P C 5 8 0 Wiri ng Di ag ram
ii
               S e c tion 1 : Sy s te m Intro d u cti o n
1.1    Specifications                                             Digital Communicator Specifications*
                                                                  • Supports major communication formats including SIA and
Downloading Software Support                                        Contact ID
• PC580 v2.3 uses DLS-1 v6.7 and up.
                                                                  • Digital Communicator compatible receivers and their formats:
Flexible Zone Configuration                                         Silent Knight Model 9000: 3/1, 4/1, 4/2 non-extended, 3/1
• Four fully programmable zones                                     extended, 20 bps, 1400 Hz handshake.
• System expandable to 8 zones using keypad zone inputs and         Ademco Model 685: 3/1, 4/1, 4/2 non-extended, 3/1
   to 32 zones using the PC5132 wireless expansion module           extended, 20 bps, 1400 Hz handshake, Contact ID.
• 38 access codes: one master code, one maintenance                 Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended, 3/1
   code, two duress codes, two supervision codes and 32             extended, 20 bps, 1400 Hz handshake.
   general access codes                                             Radionics Model D6500: 3/1, 4/2 non-extended, 3/1
• 27 zone types; 8 programmable zone attributes                     extended, with or without parity, 1400 and 2300 Hz handshake.
• Normally closed, single EOL and double EOL zone wiring            Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without parity, 20
• 32 wireless zones with the PC5132 Wireless Receiver               bps, 1400 and 2300 Hz handshake, Contact ID, SIA.
                                                                  • Event-initiated personal paging
Audible Alarm Output
                                                                  • Three programmable telephone numbers
• 700mA Supervised Bell Output (current limited at 3 amps),
  12VDC                                                           • Two account numbers
• Steady or Pulsed Output                                         • Supports LINKS1000 cellular communication
                                                                  • Supports LINKS2X50 long range radio transmitter
EEPROM Memory                                                     • Supports Skyroute transceiver
• Does not lose programming or system status on complete          • DTMF and pulse dialing
  AC and Battery failure                                          • DPDT line seizure
Programmable Outputs                                              • Anti-jam feature
• Two programmable outputs; 18 programmable options               • Split reporting of selected transmissions to each telephone
• PGM1 = 50mA; PGM2 = 50mA                                          number
Powerful 1.5 Amp Regulated Power Supply                           System Supervision Features
• 550 mA Auxiliary Supply, 12 VDC                                 The PC580 continuously monitors a number of possible trou-
• Positive Temperature Coefficient (PTC) components               ble conditions including:
  replace fuses                                                   • AC power failure             • AUX Power Supply Trouble
• Supervision for loss of AC power, low battery                   • Fault by zone                • Loss of internal clock
• Internal clock locked to AC power frequency                     • Tamper by zone               • Bell output trouble
Power Requirements                                                • Fire trouble                 • Telephone line trouble
• Transformer = 16.5 VAC, 40VA                                    • Failure to communicate       • Low battery condition (panel)
• Battery = 12 volt 4 Ah minimum rechargeable sealed lead         • Low battery by zone (wireless)
   acid battery                                                   • Module fault (supervisory or tamper)
• For household fire and burglary installations, two 7Ah bat-     False Alarm Prevention Features
   teries in parallel must be used, providing 24 hours of         • Audible Exit Delay     • Quick Exit
   standby power and 4 minutes of alarm output power.             • Audible Exit Fault     • Cross Zone Burglary Alarm
• For commercial burglary installations, a 4Ah (or larger) bat-   • Communication Delay    • Rotating Keypress Buffer
   tery must be used, providing at least 4 hours of standby       • Urgency on Entry Delay
   power and 4 minutes of alarm output power.
                                                                  Additional Features
WARNING: Do not install this panel outside of North America.
                                                                  • Auto Arm at specified time
By design, this panel will not work if the AC line frequency
                                                                  • Keypad-activated alarm output and communicator test
drops below 55.5Hz.                                               • All modules connect to the system via a four wire Keybus
Remote Keypad Specifications                                        up to 1000’/305m from main panel
• Keypads available:                                              • An event buffer which records the past 128 events with
  - PC1555RKZ eight zone LED keypad with zone input                 both the time and date at which they occurred; buffer can
  - PC5508Z eight zone LED keypad with zone input                   be printed using PC5400 serial interface module, or
  - PC5516Z sixteen zone LED keypad with zone input                 viewed with the LCD5500Z keypad and DLS-1 software
  - PC5532Z thirty-two zone LED keypad with zone input            • Supports the addition of the PC5132 wireless receiver for
  - LCD5500Z Alphanumeric keypad with zone input                    integration of wireless devices
• All keypads have five programmable function keys                • Uploading and downloading capability
• Connect up to eight keypads                                     • Local downloading capability through the use of the
• 4-wire (Quad) connection to Keybus                                PC-LINK adaptor
• Built in piezoelectric buzzer                                   • Added Keybus fault protection: clock and data outputs
                                                                    have been programmed to withstand shorts to +12v to pre-
                                                                    vent control panel damage
2                                             *WLS910, LINKS1000, LINKS2X50, and Skyroute have not been investigated by UL.
                       S ec tion 2: Ge tti ng Starte d
The following sections provide a thorough description of how      Step 10: Testing the System
to wire and configure devices and zones.                          Test the panel thoroughly to ensure that all features and func-
                                                                  tions are operating as programmed.
2.1    Installation Steps
Read this section completely before you begin. Once you           2.2     Terminal Descriptions
have an overall understanding of the installation process,        Battery Connection
carefully work through each step.                                 A 12V 4Ah rechargeable battery is used as a backup source
Step 1: Create a Layout                                           of power in the event of an AC power failure. The battery also
Draw a rough sketch of the building to get an idea of where all   provides additional current when the panel’s demands exceed
alarm detection devices, keypads and other modules are to         the power output of the transformer, such as when the panel is
be located.                                                       in alarm.
Step 2: Mounting the Panel                                        NOTE:Do not connect the battery until all other wiring is com-
Mount the panel in a dry area close to an unswitched AC           plete. Connect the battery before connecting the AC.
power source and the incoming telephone line. Before attach-      Connect the RED battery lead to the positive battery terminal;
ing the cabinet to the wall, be sure to press the four circuit    connect the BLACK lead to negative.
board mounting studs into the cabinet from the back. After
you have attached the cabinet to the wall, stick the provided     AC Terminals – AC
DSC logo sticker on the front of the cabinet.                     The panel requires a 16.5VAC, 40VA transformer. Connect the
                                                                  transformer to an unswitched AC source and connect the
NOTE:You must complete all wiring before connecting the bat-      transformer to these terminals.
tery, or applying AC to the panel.
                                                                  NOTE:Do not connect the transformer until all other wiring is
Step 3: Wiring the Keybus (Section 2.3)                           complete.
Wire the Keybus to each of the modules following the guide-
lines provided in Section 2.3 of this manual.                     Auxiliary Power Terminals – AUX+ and AUX-
                                                                  These terminals provide up to 550 mA of additional current at
Step 4: Zone Wiring (Section 2.8)                                 12 VDC for devices requiring power. Connect the positive side
You must power down the control panel to complete all zone        of any device requiring power to the AUX+ terminal, the nega-
wiring. Please refer to 2.8 “Zone Wiring” on page 5 when con-     tive side to AUX- (ground). The AUX output is protected. This
necting zones using normally closed loops, single EOL resis-      means that if too much current is drawn from these terminals
tors, double EOL resistors, Fire zones and Keyswitch Arming       (such as a wiring short), the panel will temporarily shut off the
zones.                                                            output until the problem is corrected.
Step 5: Complete Wiring (Section 2.2)                             Bell Output Terminals – BELL+ and BELL-
Complete all other wiring including bells or sirens, telephone    These terminals provide up to 700 mA of continuous current at
line connections, and ground connections following the guide-     12 VDC for powering bells, sirens, strobes or other warning-
lines provided in Section 2.2 (“Terminal Descriptions”).          type equipment. Connect the positive side of any alarm warn-
Step 6: Power up the Control                                      ing device to BELL+, the negative side to BELL–. Please note
Once all zone and Keybus wiring is complete, power up the         that the Bell output is protected: if too much current is drawn
control panel. First, connect the red battery lead to the posi-   from these terminals (such as a wiring short), the Bell PTC will
tive terminal and the black lead to negative. Then, connect the   open. Three amps can be drawn for short periods only.
AC.                                                               The Bell output is supervised. If no alarm warning devices are
NOTE: Connect the battery before connecting the AC. You           in use, connect a 1000Ω resistor across BELL+ and BELL– to
must apply AC power to the panel for at least 10 seconds, or      prevent the panel from displaying a trouble condition. For
the panel will not function. The panel will not power up on the   more information, please refer to “[*][2] Trouble Display” on
battery connection alone.                                         page 9).
                                                                                             For UL installations, when a bell or
Step 7: Keypad Assignment (Section 2.5)                                                      siren is used for fire signaling with a
In order for keypads to be properly supervised, each must be                                 pulsed cadence, it must be con-
assigned to a different slot. Please follow the guidelines pro-                              nected between the AUX+ and
vided in Section 2.5 when assigning keypads.                                                 BELL- terminals. To maintain bell cir-
Step 8: Supervision (Section 2.6)                                                            cuit supervision, do not connect
The supervision of each module by the panel is automatically                                 more than one device to the BELL-
enabled upon power up. Please verify that all modules appear                                 terminal. A fire bell or siren used for
on the system according to the instructions in Section 2.6.       this application must be UL Listed and have a current con-
Step 9: Programming the System (Sections 4 & 5)                   sumption of 400mA or less (e.g. Wheelock MT-12/24-R).
Section 4 explains how to program the panel. Section 5 con-       Keybus Terminals – AUX+, AUX-, YEL, GRN
tains a complete description of the various programmable fea-     The Keybus is used by the panel to communicate with mod-
tures, which options are available and how they function. Fill    ules and vice versa. Each module has four Keybus terminals
out the Programming Worksheets completely before attempt-         that must be connected to the four Keybus terminals on the
ing to program the system.                                        panel. For more information, see section 2.3 “Keybus Opera-
                                                                  tion and Wiring” on page 4.
                                                                                                                                  3
Programmable Output Terminals – PGM1 and PGM2                     • No module can be more than 1,000'/305m (in wire length)
Each PGM output is designed so that when activated by the           from the panel.
panel, the terminal will switch to ground                         • Shielded wire should not be used.
                                 PGM1 can sink up to 50mA of      Example of Keybus Wiring
                                 current. Connect the positive    NOTE:
                                 side of the LED or buzzer to     Module (A) is correctly
                                 AUX+, the negative side to       wired within 1,000'/
                                 PGM1. PGM2 operates simi-        305m of wire from the
                                 larly to PGM1. If more than 50   panel.
                                 mA of current are required, a
                                                                  Module (B) is correctly
                                 relay must be used.
                                                                  wired within 1,000'/
                                 Please study PGM wiring in       305m of wire from the
                                 the accompanying diagram.        panel.
                                 For a list of the programmable   Module (C) is NOT wired correctly as it is further than 1,000'/
                                 output options, please see       305m from the panel, in wire distance.
                                 section 5.11 “PGM Output
                                 Options” on page 20.             2.4 Current Ratings – Modules and Acces-
                              Zone Input Terminals –              sories
                              Z1 to Z4                            In order for the PC580 system to operate properly, the power
Each detection device must be connected to a zone on the          output capabilities of the main control and the expansion
control panel. We suggest that one detection device be con-       devices must not be exceeded. Use the data presented below
nected to each zone; wiring multiple detection devices to a       to ensure that no part of the system is overloaded and cannot
single zone, however, is possible. For zone wiring specifics,     function properly.
please see section 2.8 “Zone Wiring” on page 5.                   PC580 (12 VDC)
Telephone Connection Terminals – TIP, RING, T-1, R-1              AUX+: ........550mA: Subtract the listed rating for each key-
If a telephone line is required for central station communica-                   pad, expansion module and accessory con-
tion or downloading, connect an RJ-31X telephone jack in the                     nected to AUX+ or Keybus.
following manner:                                                 BELL: .........700mA continuous rating; 3.0A short term. Avail-
                                                                                 able only with standby battery connected.
                                                                  PC580 Device Ratings (at 12 VDC)
                                                                  • LCD5500Z Keypad: 85mA max.
                                                                  • PC1555RKZ Keypad: 85mA max.
                                                                  • PC5508Z, PC5516Z, PC5532Z Keypads: 85mA max.
                                                                  • PC5400 Serial Module: 65mA
                                                                  • PC5132 Wireless Receiver: 125mA
NOTE:Please ensure that all plugs and jacks meet the dimen-       Other Devices
sion, tolerance and metallic plating requirements of 47 C.F.R.    Please read the manufacturer’s literature carefully to deter-
                                                                  mine the maximum current requirements for each device—
Part 68, SubPart F. For proper operation, no other telephone
                                                                  during activation or alarm—and include the proper values for
equipment should be connected between the control panel and
                                                                  loading calculations. Connected devices must not exceed
the telephone company facilities. Do not connect the alarm
                                                                  system capabilities during any possible operational mode.
panel communicator to telephone lines intended for use with a
fax machine. These lines may incorporate a voice filter which     2.5    Keypad Assignment
disconnects the line if anything other than fax signals are       There are eight available slots for keypads. LED keypads by
detected, resulting in incomplete transmissions.                  default are always assigned to slot 1. LCD5500Z keypads are
                                                                  always assigned to slot 8. You will need to assign each key-
2.3    Keybus Operation and Wiring
                                                                  pad to its own slot (1 to 8). Keypad assignment is required, as
The Keybus is used by the panel to communicate with all con-
                                                                  it tells the panel which slots are occupied. The panel can then
nected modules and vice versa. The red (AUX+) and black
                                                                  generate a fault when a keypad supervisory is not present.
(AUX-) terminals are used to provide power, while the yellow
(YEL) and green (GRN) terminals are clock and data respec-        NOTE: One LCD keypad must be assigned to slot 8 in order to
tively.                                                           upload keypad programming using DLS-1 software.
NOTE: The four Keybus terminals of the panel must be con-         How to Assign Keypads
nected to the four Keybus terminals or wires of all modules.      Do the following at each keypad installed on the system:
                                                                  1. Enter [*][8][installer’s code] to go to installer programming
The following restrictions apply to Keybus wiring:
                                                                  2. Enter [000] for Keypad Programming
• Keybus should be run in minimum 22 gauge quad
                                                                  3. Enter [0] for Slot Assignment
   (0.5mm); two pair twist is preferred.
                                                                  4. Enter a two digit number (11-18) to specify which supervi-
• The modules should be home-run to the panel but can be             sory slot the keypad will occupy.
   connected in series or T-tapped.                               5. Press [#] twice to exit installer programming.
• Any module can be connected anywhere along the Key-             After assigning all keypads, perform a supervisory reset by
   bus. You do not need to run a separate Keybus wire for         entering section [902] in installer’s programming. The panel
   keypads, etc.
4
                                                                        G e t t i n g   S t a r t e d :   2 . 6   S u p e r v i s i o n
will now supervise all assigned keypads and enrolled modules       power it back up. If you do not, the zones may not work cor-
on the system.                                                     rectly.
How to Program Function Keys                                       Normally Closed (NC) Loops
By default, the 5 function keys on each keypad are pro-
grammed as Stay Arm (03), Away Arm (04), Chime (06), Sen-
sor Reset (14) and Quick Exit (16). You can change the
function of each key on every keypad:
1. Go to the keypad where you want to change the function
    key programming and enter Installer Programming.
2. Press [000] for Keypad Programming.
3. Enter [1] to [5] to select a function key to program.           To enable normally closed loops, programming section [013],
4. Enter the 2 digit number, [00] to [17] to select the feature    option [1] must be ON.
    you want the function key to have. For a complete list of      NOTE:This option should only be selected if Normally Closed
    Function Key options see section 3.5 “Function Keys” on        (NC) detection devices or contacts are being used.
    page 11.
5. Continue from step 3 until all function keys are pro-           Single End Of Line (EOL) Resistors (5600Ω)
    grammed.                                                       To enable panel detection of single end of line resistors, pro-
6. To exit Installer Programming, press [#] twice.                 gramming section [013], options [1] and [2] must be OFF.
2.6    Supervision
By default, all modules are supervised upon installation.
Supervision is enabled at all times so that the panel can indi-
cate a trouble if a module is removed from the system.
To check which modules are currently connected and super-
vised, enter programming section [903] from installer’s pro-
gramming. The LCD keypad will allow you to scroll through the
display of connected modules. A connected module which
does not show as being present will appear as a trouble con-
dition and the Trouble light on the keypad will turn ON. This
condition may be due to one or more of the following reasons:
• the module is not connected to the Keybus
• there is a Keybus wiring problem
• the module is more than 1,000'/305m from the panel               NOTE:This option should be selected if either Normally Closed
• the module does not have enough power                            (NC) or Normally Open (NO) detection devices or contacts are
For more information regarding module supervision troubles,        being used.
please refer to “[*][2] Trouble Display” on page 9.
                                                                   Double End of Line (DEOL) Resistors
2.7    Removing Modules                                            Double End of Line resistors allow the panel to determine if the
The panel must be instructed to no longer supervise a module       zone is in alarm, tampered or faulted.
being removed from the system. To remove the module, dis-          To enable panel detection of double end of line resistors, pro-
connect it from the Keybus and reset the supervision field by      gramming section [013], option [1] must be OFF and option
entering [902] in the installer’s programming. The panel will be   [2] must be ON.
reset to recognize and supervise all existing modules on the       NOTE: If the Double EOL supervision option is enabled, all
system.                                                            hardwire zones on the main panel must be wired for Double
                                                                   EOL resistors, except for Fire and 24 Hour Supervisory zones.
2.8    Zone Wiring                                                 NOTE:Do not wire DEOL resistors on keypad zones.
For a complete description of the operation of all zone types,
please refer to 5.2 “Zone Programming” on page 15.                 NOTE: Do not use DEOL resistors for Fire zones or 24 Hour
There are several different ways in which zones may be wired,      Supervisory zones. Do not wire Fire zones to keypad zone ter-
depending on which programming options have been                   minals if the DEOL supervision option is selected.
selected. The panel can be programmed to supervise nor-
mally closed, End of Line, or Double End of Line loops. Please
refer to the following diagrams to study each type of individu-
ally supervised zone wiring.
NOTE:Any zone programmed for Fire or 24 Hour Supervisory
must be wired with a single End of Line (EOL) resistor regard-
less of the type of zone wiring supervision selected for the
panel (section [013]: [1] -[2]). See 5.2 “Zone Programming” on
page 15.                                                           NOTE: This option can only be selected if Normally Closed
                                                                   (NC) detection devices or contacts are being used.
NOTE:If you change the zone supervision options from DEOL
to EOL or from NC to DEOL (section [013], options [1] or [2]),     NOTE:Only one NC contact can be connected to each zone.
you should power down the system completely, and then              Wiring multiple detection devices or contacts on a single loop
                                                                   is not allowed.
                                                                                                                                     5
The following chart shows zone status under certain condi-                    LINKS Answer
tions:                                                                        When using the LINKS1000
           Loop Resistance              Loop Status                           cellular communicator, any
    0Ω (shorted wire, loop shorted)         Fault                             main board zone may be
        5600Ω (contact closed)            Secure                              configured     for     LINKS
   Infinite (broken wire, loop open)      Tamper                              Answer.
        11200Ω (contact open)             Violated                            A zone configured for
                                                                              LINKS      Answer      allows
End of Line Resistors. . . . . . . . . . . . . . . . . . Section [013]: [1]   downloading to be per-
Double End of Line Resistors . . . . . . . . . . . Section [013]: [2]         formed in the event of tele-
                                                                              phone line failure. When
                                                                              the LINKS receives a tele-
2.9      Fire Zone Wiring                                                     phone call, it will activate
NOTE:4-Wire Smoke Detectors                                                   the RING terminal on the
All fire zones must be wired according to the following dia-                  LINKS circuit board. The
gram:                                                                         zone     programmed        as
                                                                              LINKS Answer          always
                                                                              requires a single EOL resis-
                                                                              tor (5600Ω).
                                                                              Wire the LINKS Answer zone according to the above diagram.
                                                                              NOTE: The LINKS Answer zone is only required for download-
                                                                              ing to the panel via the LINKS.
                                                                              NOTE: When using the LINKS, Busy Tone Detection must not
                                                                              be used.
                                                                              NOTE: Keypad zones cannot be used for 24 Hour Supervisory
                                                                              or LINKS Answer.
                                                                                                                                   7
                  S e c tion 3 : Ke y p ad Co mmand s
Use any system keypad to enter commands and/or program               3.3     Automatic Arming
the PC580 security system. The LED keypad uses function              The system can be programmed to Auto-Arm at a specific
and zone indicator lights to represent alarm functions and sta-      time every day if it is in the disarmed condition. In order for the
tus. If you have a PC1555RKZ keypad, the System light acts           Auto-Arm function to work properly, you must program the cor-
as a Trouble, Memory, Program and Bypass indicator. Unlike           rect Time of Day. For programming the clock and auto-arm
other LED keypads, these conditions will only be represented         times, see “[*][6] User Functions” on page 10.
by the System light.                                                 When the system’s internal clock matches the Auto-Arm Time,
The LCD keypad provides a written description on the liquid          the panel will check the system status. If the system is armed,
crystal display and uses function indicator lights to communi-       the panel will do nothing until the next day at the auto-arm
cate alarm status to the user.                                       time, when it will check the system again. If the system is dis-
The PC580 Instruction Manual provides basic directions for           armed at the auto-arm time, the panel will sound the buzzer of
arming and disarming the system, bypassing zones and per-            all keypads for one minute. If the Bell Squawk During Auto
forming user functions from the keypads. The following sec-          Arm option is enabled (section [014], option [2]), the bell will
tions provide additional details on these functions.                 squawk once every 10 seconds while the system is auto-arm-
                                                                     ing. If a valid access code is entered, auto-arming will be
3.1     Arming and Disarming                                         aborted.
For a description of basic arming and disarming, please see          NOTE: If auto-arm is cancelled, the number of the user who
the PC580 Instruction Manual. For other methods of arming,           cancelled the auto-arm will be logged in the event buffer.
please refer to “[*][0] Quick Arm”, “[*][9] Arming Without Entry
Delay” and 3.5 “Function Keys” on page 11.                           If no code is entered, the panel will auto-arm. If a zone is vio-
                                                                     lated, the panel will transmit a Partial Closing Reporting Code
NOTE: The event buffer will log “Armed in Stay Mode” or
                                                                     – if programmed – to indicate to the central station that the
“Armed in Away Mode” whenever the system is armed.
                                                                     system is not secure. If the zone is restored, the panel will add
In an attempt to prevent false alarms, the Audible Exit Fault        the zone back into the system.
will notify the user of an improper exit when they arm their sys-    NOTE: Auto arming can only be cancelled by entering a valid
tem. If a non force-arming Delay 1 or Delay 2 type zone is left      access code at any keypad.
open at the end of the exit delay, the entry delay will begin
immediately and the bell or siren will sound a steady alarm for      3.4     [*] Commands
the entry delay period. At the end of the entry delay period, if     The [*] key commands provide an easy way for the user to
the system has not been disarmed it will go into alarm. This         access basic system programming – such as programming
feature can be turned OFF in programming section [013],              access codes or bypassing zones. The user can also use the
option [6]. (See 5.17 “Arming/Disarming Options” on page             [*] key commands to check on the system’s status, including
23.)                                                                 viewing trouble conditions and displaying the event buffer on
                                                                     the LCD keypad.
3.2     Auto Bypass – Stay Arming
                                                                     The [*] key commands can be performed from both LCD and
Stay arming allows the user to arm the system without leaving
                                                                     LED keypads. The LED keypad uses the zone indicator lights
the premises. All zones programmed as stay/away will be
                                                                     to display command information. The LCD display provides
bypassed when the user stay arms the system, so that the
                                                                     written information, guiding the user through each command.
user does not have to bypass interior zones manually. (See
                                                                     The commands in this section are explained as viewed from
5.2 “Zone Programming” on page 15.)
                                                                     an LED keypad. When using an LCD keypad, use the arrow
When the system is armed using a valid access code, if any           keys (< >) to scroll through information provided. Otherwise,
zones on the system have been programmed as stay/away                the functions remain the same for both keypad types.
zones, the Bypass light will turn ON. The panel will then moni-
tor all zones programmed as Delay 1 and Delay 2 zones, such          [*][1] Bypassing and Activating Stay/Away Zones
as designated entry/exit doors. If a delay zone is not violated      Use the [*][1] keypad command to bypass individual zones. A
by the end of the exit delay, the panel will bypass all stay/away    bypassed zone will not cause an alarm.
zones. The Bypass light will remain on to inform the user that       NOTE: Zones can only be bypassed when the system is not
the interior zones have been automatically bypassed by the           armed.
panel. If a delay zone is violated during the exit delay, the sys-   If the Code Required for Bypass option is enabled (section
tem will arm in Away mode and all stay/away zones will be            [015], option [5]), only access codes with the bypass attribute
active after the exit delay expires.                                 enabled will be able to bypass zones. (See 5.1 “Programming
The user can arm the stay/away zones at any time by entering         Security Codes” on page 15.)
the [*][1] keypad command. (See “[*][1] Bypassing and Acti-          If the Bypass Status Displayed While Armed option is cho-
vating Stay/Away Zones” on page 8.)                                  sen, the Bypass (or System) light will be ON while the system
Stay arming can also be initiated by pressing and holding the        is armed to indicate any bypassed zones. (See 5.17 “Arming/
Stay function key for two seconds on the PC5508Z and                 Disarming Options” on page 23.)
LCD5500Z keypads, if programmed by the installer. For more
                                                                     NOTE: When you disarm the system, all manually-bypassed
information regarding Stay arming, please see 3.5 “Function
                                                                     zones will be unbypassed.
Keys” on page 11.
8
                                                                           K e y p a d      C o m m a n d s :         3. 4   [ *]   C om m a n ds
         Light   Trouble
           1     Service Required: Press [1] to determine the specific trouble. Lights 1 - 5 will light up to indicate the trouble:
                 • Light [1] Low Battery: Main panel backup battery charge is low (below 11.5 volts under load).Trouble is restored
                             when the battery charges over 12.5 volts.
                 • Light [2] Bell Circuit Trouble: The bell circuit is open (see section 5.13 “Bell” on page 22).
                 • Light [3] General System Trouble: The printer connected to the PC5400 Printer module has a fault and is off-line.
                 • Light [4] General System Tamper: Tamper has been detected in a module.
                 • Light [5] General System Supervisory: The panel has lost communication with a module connected to the Keybus
                             (see section 2.6 “Supervision” on page 5). The event buffer will log the event.
                 NOTE: All tamper conditions must be physically restored before the trouble condition will clear.
                 NOTE:Lights [6-8] – Not used
           2     AC Failure: AC power is no longer being supplied to the control panel. The Trouble (or System) light will flash if an AC
                 Failure is present, if the Trouble Light Flashes if AC Fails option is programmed (section [016], option [2]). This trouble
                 will not be displayed if the AC Trouble Displayed option is disabled (section [016], option [1]). See section 5.8 “Com-
                 municator – Reporting Codes” on page 18 for information on AC trouble reporting.
           3     Telephone Line Monitoring Trouble (TLM): There is a problem with the telephone line (See section 5.12 “Tele-
                 phone Line Monitor (TLM)” on page 22.)
           4     Failure to Communicate (FTC): The communicator failed to communicate with any of the programmed telephone
                 numbers (see section 5.5 “Communicator – Dialing” on page 17).
           5     Zone Fault (including Fire Zone): A zone on the system is experiencing trouble, meaning that a zone could not
                 provide an alarm to the panel if required to do so (e.g. a fire zone is open, or there is a short on a DEOL zone, or a super-
                 visory fault on a wireless zone). When a zone fault trouble condition occurs, the keypad(s) on the system will start to
                 beep. Press [5] while in Trouble mode to view the affected zones.
                 NOTE: A Fire zone trouble will be generated and displayed in the armed state.
           6     Zone Tamper: A zone configured for Double End Of Line resistor supervision has a tamper condition, or the tamper
                 switch is open on a wireless device. When a tamper condition occurs, the keypad(s) will start to beep. Press [6] while in the
                 Trouble mode to view the affected zones. If a zone is tampered or faulted, it must be fully restored to clear the trouble.
                 NOTE: By enabling Tampers/Faults Do Not Show as Open in section [013], option [4], Faults and Tampers will not show
                 as open on the keypad, and will be hidden from the end user. If the option is disabled, Faults and Tampers will be dis-
                 played on the keypad
                 NOTE:Once a zone is tampered or faulted, it must be completely restored before the trouble condition will clear.
           7     Device Low Battery: A wireless device has a low battery condition. Press [7] one, two, or three times to view which
                 devices are experiencing battery failure. An LED keypad will indicate battery failure using zone lights 1 to 8. The follow-
                 ing will occur:
                                Keypad beeps: Keypad displays:
                 Press [7]             1         Zones with low batteries (LED keypad - zone lights 1 to 32)
                 Press [7] again        2        Handheld keypads with low batteries (LED keypad - zone lights 1 to 4)
                 Press [7] again        3        Wireless keys with low batteries (LED keypad - zone lights 1 to 8)
                               To view the battery conditions of wireless keys 9 through 16, you must use an LCD keypad.
           8     Loss of System Time: When the panel is powered up, the internal clock needs to be set to the correct time. This
                 trouble is cleared when an attempt is made to reset the clock.
                                                                                                                                                 9
[*][5] Programming Access Codes                                        [*][6] User Functions
There are 37 access codes available to the user. They are:             This command can be used to program several different func-
Access code (40) ..................... One master code                 tions:
Access codes (01)-(32)............ 32 general access codes             To program User Functions:
Access codes (33)-(34)............ Two duress codes                    1. Press [*][6][Master Code]. The Program (or System) light
Access codes (41)-(42)............ Two supervisor codes                    will flash.
All access codes have the ability to arm or disarm the system          2. Press the number [1] to [6] for the item to be programmed.
and can activate the PGM Outputs using the [*][7] com-                 • [1] – Time and Date
mands.                                                                     The time and date must be accurate for the auto-arm or
For a description of how to program access codes from LCD                  test transmission functions to work properly and for the
or LED keypads, see the PC580 Instruction Manual.                          event buffer to time and date stamp all events.
                                                                           - Enter the time (hour and minute) using 24hr format [HH
Master Code – Access Code (40)                                             MM] from 00:00 to 23:59.
This code can be used to program all access codes. The                     - Enter the date by month, day and year [MM DD YY].
Master code has all Access Code Attributes enabled by                  • [2] – Auto-Arm Enable/Disable
default, so that the Master code can be used to perform any                To enable or disable auto-arming, press [2]. The keypad
keypad function. Master code attributes cannot be changed.                 will sound three short beeps when auto-arm is enabled
If the Master Code Not Changeable option is enabled, (sec-                 and one long beep when disabled. For more information,
tion [015], option [6]) the Master Code can only be changed                see 3.3 “Automatic Arming” on page 8.
by the Installer.
                                                                       • [3] – Auto-Arm Time
General Access Codes – Access Codes (01) to (32)                           The system can be programmed to arm automatically at a
General access codes can arm and disarm the system. When                   pre-set time. When programming the auto-arm time, enter
the Code Required for Bypassing option is enabled, users                   the time (hour and minute) using 24hr format [HH MM]. For
will need to enter a valid access code when bypassing zones.               more information, see 3.3 “Automatic Arming” on page 8.
Individual access codes can have the Zone Bypassing                    • [4] – System Test
attribute disabled under Access Code Attribute programming.                When [4] is pressed the panel will test the bell output, key-
For more information regarding access code options, please                 pad lights and the communicator for two seconds. The
see 5.1 “Programming Security Codes” on page 15.                           panel will also send a System Test Reporting code, if pro-
Duress Code – Access Code (33) and (34)                                    grammed. (See 5.8 “Communicator – Reporting Codes” on
Duress codes will send a duress reporting code to the central              page 18.)
station when entered.                                                  • [5] – Enable DLS (Downloading)
NOTE: If a duress code is programmed, when it is used, the                 When [5] is pressed, the panel will enable the downloading
panel will always send a reporting code to the central station,            option for six hours. During this time, the panel will answer
even if the attributes of the duress code are turned off.                  incoming downloading calls. (See 5.10 “Downloading” on
                                                                           page 20.)
Supervisor Codes – Access Code (41) and (42)                           • [6] – User Initiated Call-Up
These codes can be used to program general access and                      When [6] is pressed, the panel will initiate a call to the
duress codes. The two supervisor codes have all attributes on              downloading computer.
by default. These settings can be changed.
                                                                       Additional Features Available from the LCD Keypad
Access Code Attributes                                                 Additional features, including access to the event buffer, are
There are three access code attributes which can be pro-
                                                                       available using the LCD keypad. Use the arrow keys (< >) to
grammed for each code.                                                 scroll through the [*][6] menu and press the [*] key to select
To program each attribute, enter [*][5][Master Code][9] to             the following commands:
enter the attribute programming mode. Then enter the code
number [01-32,33,34,41,42]. Enter the attribute number:                Viewing the Event Buffer from an LCD Keypad
                                                                       Select “View Event Buffer” from the [*][6] menu. The keypad
Attribute [1].......... User enabled for arming, disarming, alarm
                                                                       will display the event, event number, time and date along with
                        reset, [*][7][1-2] options, auto arm cancel-
                                                                       the zone number and access code, if applicable. Press [*] to
                        lation
                                                                       toggle between this information and the event itself. Use the
Attribute [2].......... Not used                                       arrow keys (<>) to scroll through the events in the buffer.
Attribute [3].......... Zone bypassing enabled                         When you have finished viewing the event buffer, press [#] to
Attribute [4]-[6] .... Not used                                        exit.
Attribute [7].......... Bell squawk on access code entry               Brightness Control
Example: You can use the arm/disarm bell squawk attribute to           You can select from 10 different backlighting levels. Use the
have wireless key access codes squawk the bell, while other            arrow keys (< >) to scroll to the desired backlighting level.
codes are silent. To do this, enable attribute [7] on all access       Press [#] to exit.
codes associated with wireless keys.
                                                                       Contrast Control
NOTE: If you enable the Bell Squawk on Arming/Disarming                You can select from 10 different display contrast levels. Use
(section [014], option [1]), the bell will sound arm/disarm bell       the arrow keys (< >) to scroll to the desired contrast level.
squawks for all access codes, regardless of the programming            Press [#] to exit.
for attribute [7]. See 5.17 “Arming/Disarming Options” on
page 23.                                                               Keypad Sounder Control
                                                                       You can select from 21 different keypad tones. Use the arrow
NOTE: Master code attributes cannot be changed.                        keys (< >) to scroll to the desired keypad sound level and
10
                                                                    K e y p a d   C o m m a n d s :     3 . 5   F u nc t io n   K e y s
press [#] to exit. This feature can be accessed on LED key-          If the Quick Arm option is disabled (section [015], option [4]),
pads by pressing and holding the [*] key.                            users will need to enter an access code after pressing a func-
[*][7] Command Output Functions                                      tion key.
The user can activate programmable output functions using            NOTE:On the PC1555RKZ keypad, use number keys 1 - 5 for
the [*][7][1-2] commands. The outputs may be activated when          the function keys.
the system is either armed or disarmed.                              “Stay” – (03) Stay Arm
[*] [7] [1] – Command Output Option #1:                              The system will arm in the Stay mode (see 3.2 “Auto Bypass –
Press [*] [7] [1] [Access Code, if required] to activate outputs     Stay Arming” on page 8). Enable the Quick Arm feature (pro-
programmed as PGM output option [19]. This output can be             gramming section [015], option [4]) to have this key function
used for operating devices such a garage door opener, light-         without the need to enter an access code. If Quick Arm is not
ing or door strikes.                                                 enabled, the user will have to enter an access code before the
[*][7][2] – Command Output Option #2:                                system will stay arm.
Press [*][7][2][Access Code, if required] to activate all outputs    “Away” – (04) Away Arm
programmed as one of PGM output options [03] or [20].                The system will arm in the Away mode (see 3.2 “Auto Bypass
Special Note: Traditionally, [*][7][2] has been reserved for         – Stay Arming” on page 8). Enable the Quick Arm feature (pro-
resetting smoke detectors. Smoke detectors should now be             gramming section [015], option [4]) to have this key function
programmed as output [03] “Sensor Reset” . If using output           without the need to enter an access code. If Quick Arm is not
option [03], do not program [20] Command Output Option #2.           enabled, the user will have to enter an access code before the
Please see 5.11 “PGM Output Options” on page 20 for more             system will away arm.
information.                                                         When the panel is being Away armed, users can restart the
[*][8] Installer’s Programming                                       exit delay once, by pressing the Away button before the exit
Enter [*][8] followed by the Installer’s Code to access              delay expires. This will not work if the panel is being Stay
Installer’s Programming. See sections 4 and 5 for more infor-        armed.
mation.                                                              “Chime” – (06) Door Chime On / Off
[*][9] Arming Without Entry Delay                                    The Door Chime feature will turn ON or OFF. (See “[*][4] Door
When the system is armed with the [*][9] command, the panel          Chime On/Off” on page 9.)
will cancel the entry delay. Delay 1 and Delay 2 type zones will     “Reset” – (14) Sensor Reset or [*][7][2]
be instant and Stay/Away zones will be bypassed as soon as           The panel will activate all PGM outputs programmed as option
the exit delay has ended (see section 5.2 “Zone Program-             [03] Sensor Reset or [20] Command Output Option #2. (See
ming” on page 15). The user must enter a valid access code           “[*][7] Command Output Functions” .)
after pressing [*][9].                                               “Exit” – (16) Activate Quick Exit
[*][0] Quick Arm                                                     The panel will activate the Quick Exit feature (See        “[*][0]
If the Quick Arm option is enabled (section [015], option [4]),      Quick Exit” on page 11.)
enter [*][0] to arm the panel without an access code. (See           Additional Function Key Options
5.17 “Arming/Disarming Options” on page 23.) If the Quick            The programming of any function key on any keypad may be
Arm option is disabled, users will need to enter an access           changed to one of the options listed below. (See 2.5 “Keypad
code after pressing a function key.                                  Assignment” on page 4 for instructions on changing function
NOTE: Quick Arm cannot be used to cancel auto arm.                   key programming.) Each option is listed according to the pro-
[*][0] Quick Exit                                                    gramming code, followed by the corresponding [*] key com-
The Quick Exit function, if enabled, will allow someone to           mand. For more information regarding each function, please
leave an armed premises through a Delay type zone without            refer to the appropriate part of Section 3.4, “[*] Commands”.
having to disarm and re-arm the system. (See 5.17 “Arming/           [00]      Null Key: The key is not used and will perform no
Disarming Options” on page 23.)                                                function when pressed.
When [*][0] is entered, the panel will provide a two minute win-     [01]-[02] For future use
dow for the user to exit the premises. During this time, the         [03]      Stay Arm: As described above.
panel will ignore only one activation of a Delay zone. When the      [04]      Away Arm: As described above.
Delay zone is secured, the panel will end the two minute quick       [05]      [*][9] No-Entry Delay Arm: A valid access code
exit delay.                                                                    must also be entered.
If a second Delay zone is tripped, or if the zone is not restored    [06]      [*][4] Door Chime On / Off: As described above.
after two minutes, the panel will begin entry delay 1.               [07]      [*][6][----][4] System Test: A valid master code must
NOTE: If the Exit Delay is in progress, performing a Quick Exit                also be entered.
will not extend the Exit Delay.                                      [08]      [*][1] Bypass Mode: A valid access code may need
                                                                               to be entered.
3.5     Function Keys                                                [09]      [*][2] Trouble Display
There are five function keys on each keypad labelled Stay,
                                                                     [10]      [*][3] Alarm Memory
Away, Chime, Reset and Exit. Each of these keys is pro-
                                                                     [11]      [*][5] Programming Access Codes: A valid master
grammed by default to perform one of the functions described
                                                                               code must also be entered.
below. Press and hold the appropriate key for two seconds to
activate a function.                                                 [12]      [*][6] User Functions: A valid master code must also
                                                                               be entered.
                                                                                                                                    11
[13]      [*][7][1] Command Output Option #1: A valid
          access code may need to be entered.
[14]      [*][7][2] Reset (Command Output Option #2): As
          described above.
[15]      For future use
[16]      [*][0] Quick Exit: As described above.
[17]      [*][1] Reactivate Stay/Away Zones
[18] - [20] For future use
12
                            S e c tion 4: Ho w to P ro g ram
The following section of the manual describes the Installer’s                     4.2     Programming Decimal Data
Programming function and how to program the various sec-                          A set number of programming boxes are allotted for each sec-
tions.                                                                            tion requiring decimal data (e.g.: codes, telephone numbers).
NOTE: Read the following section of the manual very carefully                     If a digit is entered for each program box, the panel will auto-
before you begin programming. We also recommend filling out                       matically exit from the selected programming section. The
the Programming Worksheets section before you program the                         Ready light will turn OFF and the Armed light will turn ON.
panel.                                                                            On the PC1555RKZ and PC5508Z keypads, you can also
                                                                                  press the [#] key to exit a programming section without enter-
For your reference, the corresponding programming sections                        ing data for every box. This is handy if you only need to
for the functions listed are highlighted in text boxes such as                    change digits in the first few programming boxes. All other
this one.                                                                         digits in the programming section will remain unchanged.
                                                                                                                                                  13
4.4     Programming Toggle Option Sections                           The keypad displays the information using a binary format,
Some programming sections contain several toggle options.            according to the following chart:         See Hex data
The panel will use zone lights 1 through 8 to indicate if the dif-                                                entry instructions
ferent options are enabled or disabled. Press the number cor-
responding to the option to turn it ON or OFF. Once all the
toggle options have been selected correctly, press the [#] key
to exit the section and save the changes. The Ready light will
turn OFF and the Armed light will turn ON.
Refer to the Programming Worksheets in this manual to deter-
mine what each option represents and whether the light
                                                                     Press any of the Emergency Keys (Fire, Auxiliary or Panic) to
should be ON or OFF for your application.
                                                                     advance to the next digit. When all the digits in a section have
4.5     Viewing Programming                                          been viewed, the panel will exit the section; the Ready Light
                                                                     will turn OFF and the Armed light will turn ON, waiting for the
LED Keypads                                                          next three-digit programming section number to be entered.
Any programming section can be viewed from an LED key-               Press the [#] key to exit the section
pad. When a programming section is entered, the keypad will
immediately display the first digit of information programmed        LCD Keypad
in that section.                                                     When a programming section is entered, the keypad will
                                                                     immediately display all the information programmed in that
                                                                     section. Use the arrow keys (< >) to scroll through the data
                                                                     being displayed. Scroll past the end of the data displayed or
                                                                     press the [#] key to exit the section.
14
                 S e c tion 5 : Pro gram De s cri p ti o ns
The following section explains the operation of all programma-                    should be disarmed. If the panel is disarmed before the entry
ble features and options and provides a summary of all corre-                     time expires, no alarm will be generated.
sponding programming locations.                                                   [02] Delay 2 Zone
                                                                                  The Delay 2 entry delay time can be set independently of
5.1       Programming Security Codes                                              Delay 1 in programming section [005] (System Times).
There are three codes which can be programmed by the
installer in the Installer’s Programming function: the Master                     [03] Instant Zone
code, the Installer’s code, and a Maintenance code. All other                     This zone type will cause an instant alarm if it is violated when
access codes can be programmed through the [*][5] com-                            the panel is armed. Typically, this zone is used for windows,
mand. (See “[*][5] Programming Access Codes” on page 10.)                         patio doors or other perimeter zones, and glass break detec-
                                                                                  tors.
The master code can also be programmed by the user as
access code (40). If the Master Code Not Changeable option                        [04] Interior Zone
is enabled, the system master code can only be changed by                         This zone will not cause an alarm if violated during the entry
the installer.                                                                    delay. If the zone is violated before the entry delay has begun,
The Maintenance code can only be used to arm and disarm                           it will cause an instant alarm. Typically, this zone is used for
the system. The Maintenance code cannot bypass zones, use                         interior protection devices, such as motion detectors.
[*][9] to arm the system, cancel autoarming, or perform [*][7]                    [05] Interior Stay/Away Zone
command functions. There will be no arm/disarm bell                               This zone type works similarly to the Interior zone type, except
squawks when the Maintenance code is used.                                        that it will be automatically bypassed under the following con-
General access codes can arm and disarm the system. When                          ditions:
the Code Required for Bypassing option is enabled, users                          • When the panel is armed in the Stay Mode. (See 3.5 “Func-
will need to enter a valid access code when bypassing zones.                          tion Keys” on page 11.)
Individual access codes can have the Zone Bypassing                               • When the panel is armed without entry delay. (See “[*][9]
attribute disabled under Access Code Attribute programming.                           Arming Without Entry Delay” on page 11.)
(See “[*][5] Programming Access Codes” on page 10.)                               • When the panel is armed with an access code and a Delay
If the 6-Digit User Access Codes option is enabled, all the                           type zone is NOT tripped during the exit delay.
access codes may be programmed with six digits instead of                         The automatic bypass prevents the user from having to manu-
four, with the exception of the Panel ID code and the Down-                       ally bypass interior type zones when arming at home. This
loading Access Code.                                                              zone is typically used for interior protection devices, such as
                                                                                  motion detectors.
Installer’s Code. . . . . . . . . . . . . . . . . . . . . . . . . Section [006]
Master Code. . . . . . . . . . . . . . . . . . . . . . . . . . . Section [007]    [06] Delay Stay/Away Zone
Maintenance Code . . . . . . . . . . . . . . . . . . . . . . Section [008]        This zone type will operate similarly to Interior Stay/Away
Master Code Not Changeable . . . . . . . . . . Section [015]: [6]                 zones, except that it will always provide an entry delay. Typi-
Code Required for Bypassing . . . . . . . . . . Section [015]: [5]                cally, this zone is used for interior protection devices, such as
6-digit User Access Codes . . . . . . . . . . . . Section [701]: [5]              motion detectors. This zone option will help prevent false
                                                                                  alarms since it always provides an entry delay time for the
                                                                                  user to turn off the panel.
5.2       Zone Programming                                                        NOTE: Hardwire motion detectors covering entry/exit doors
Zones 1-8 are enabled by default. Disable unused zones, or                        that are using wireless transmitters must be programmed as
enable additional zones in programming sections [202] -                           Delay Stay/Away. If not, the panel may see the motion detector
[205].                                                                            violation before the entry/exit transmitter has time to transmit to
The zone definitions describe how each of the zones you use                       the receiver, causing a false alarm.
will operate. Program a two-digit code describing the zone
definition in sections [001] - [004]. Select a definition from the                [07] Delayed 24 Hour Fire Zone
list below.                                                                       NOTE:Do not wire Fire zones on keypad zone terminals if the
In addition, each zone has eight different attributes which may                   DEOL supervision option is enabled for the panel (section
be programmed in sections [101] to [108]. (See 5.3 “Zone                          [013], option [2]).
Attributes” on page 16.)                                                          When this zone is violated, the alarm output will be immedi-
Zone Definitions                                                                  ately activated (pre-alert) but the communicator will be
                                                                                  delayed for 30 seconds. If the user presses any key on any
[00] Null Zone
                                                                                  keypad during this delay, the alarm output and the communi-
The zone is vacant. Unused zones should be programmed as
                                                                                  cator will be delayed an additional 90 seconds, giving the
Null zones.
                                                                                  user time to correct the problem. If the zone is still violated
[01] Delay 1 Zone                                                                 after the 90 second delay, the panel will sound the alarm out-
This zone type, normally used for entry/exit doors, can be vio-                   put and delay the communicator for 30 seconds.
lated during the exit delay time without causing an alarm.                        If the user does not press a key during the 30 second pre-
Once the exit delay has expired, opening the zone will start                      alert, the alarm output will latch and the panel will communi-
the entry delay timer. During the entry delay time, the keypad                    cate the alarm to the central station. The alarm will sound until
buzzer will sound steadily to advise the user that the system
                                                                                                                                                  15
the Bell Cutoff time expires (Section [005] “System Times”), or       [23] Maintained Keyswitch Arm Zone
until a code is entered. (See 5.13 “Bell” on page 22.)                When this zone is violated, the system will arm. When this
NOTE:If a second Fire type zone is violated or if the Fire keys       zone is secured, the system will disarm.
are pressed during the delay period, the panel will latch the         [24] LINKS Answer Zone
alarm output and will immediately communicate the alarm.              Downloading can be performed via the LINKS1000 Cellular
A violated Fire zone will be displayed on all keypads and can         Communicator (if used) when the conventional telephone line
be delayed at any keypad. Typically this zone is used for             is disconnected. If this operation is desired, connect the RING
latching smoke detectors.                                             terminal of the LINKS1000 to a LINKS Answer zone. (See 2.10
                                                                      “LINKS Zone Wiring*” on page 6.) Refer to the LINKS1000
[08] Standard 24 Hour Fire Zone                                       Installation Manual for more information.
NOTE:Do not wire Fire zones on keypad zone terminals if the           NOTE:Do not wire LINKS Answer zones on keypad zone ter-
DEOL supervision option is enabled for the panel (section             minals.
[013], option [2]).
                                                                      [25] Interior Delay Zone
When this zone is violated, the panel will immediately latch the      This zone type is normally used with motion detectors and has
alarm output and communicate to the central station. The              a standard exit delay time.
alarm will sound until the Bell Cutoff time expires (Section
                                                                      If the panel is Away armed (a delay zone is violated during the
[005] “System Times”), or until a code is entered. (See 5.13
                                                                      exit delay, or the Away function key is used), the Interior Delay
“Bell” on page 22.)
                                                                      zone will work the same as the Interior zone [04].
A violated Fire zone will be displayed on all keypads. Typically
                                                                      If the panel is Stay armed (a delay zone is NOT violated dur-
this zone is used for pull stations.
                                                                      ing the exit delay, the Stay key is used, or [*][9] is used for
[09] 24 Hour Supervisory Zone                                         arming), a violation of the zone will initiate Entry Delay 1.
If this zone is violated when the system is either armed or dis-
                                                                      [87] Delayed 24 Hour Fire (Wireless)
armed, the panel will report to the central station, and will log
                                                                      This zone type operates the same as [07] Delayed 24 Hour
the zone alarm to the event buffer. This zone gives a silent
                                                                      Fire Zone and must be used if the smoke detector is wireless.
alarm by default.
                                                                      [88] Standard 24 Hour Fire (Wireless)
NOTE:Do not wire 24-Hour Supervisory zones on keypad zone
                                                                      This zone type operates the same as [08] Standard 24 Hour
terminals.
                                                                      Fire Zone and must be used if the smoke detector is wireless.
[10] 24 Hour Supervisory Buzzer Zone
If this zone is violated when the system is either armed or dis-      Zone Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [001]
armed, the panel will immediately latch the keypad buzzer             Zone Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [202]
until a valid access code is entered and will immediately com-
municate to the central station.                                      5.3       Zone Attributes
[11] 24 Hour Burglary Zone                                            NOTE: All zones, with the exception of 24 Hour and Fire, will
If this zone is violated when the system is either armed or dis-      provide an exit delay.
armed, the panel will immediately latch the alarm output and
communicate to the central station. The alarm will sound until        NOTE: Do not change the attributes for Fire Zones from the
the Bell Cutoff time expires (Section [005] “System Times”), or       default settings.
until a code is entered. (See 5.13 “Bell” on page 22.)                Additional zone attributes can be programmed to customize
[12] - [20]                                                           the operation of a zone for a specific application. The follow-
The following zone definitions operate similar to the 24 Hour         ing attributes are programmable for each zone:
Burglary except for the System Event output type and the SIA          • Audible / Silent – This attribute determines whether or not
identifier:                                                              the zone will activate the alarm output.
[12] 24 Hour Holdup Zone - This zone gives a silent alarm by          • Pulsed / Steady – This attribute determines whether the
default.                                                                 alarm output will be steady or will pulse on and off every
[13] 24 Hour Gas Zone                                                    second.
[14] 24 Hour Heating Zone (N/C zone)                                  • Activate Chime – This attribute determines whether or not
[15] 24 Hour Medical Zone                                                the zone will activate the chime feature. (See “[*][4] Door
                                                                         Chime On/Off” on page 9.)
[16] 24 Hour Panic Zone
                                                                      • Bypass Enable – This attribute determines whether or not
[17] 24 Hour Non-Medical Emergency Zone
                                                                         the zone can be manually bypassed. (See “[*][1] Bypass-
[18] 24 Hour Sprinkler Zone                                              ing and Activating Stay/Away Zones” on page 8.)
[19] 24 Hour Water Flow Zone                                          • Force Arm Enable – This attribute determines whether or
[20] 24 Hour Freezer Zone                                                not the system can be armed while a zone is violated. At
[21] 24 Hour Latching Tamper                                             the end of the exit delay, if this type of zone is violated, it
If this zone is violated, the installer must enter Installer’s Pro-      will be ignored by the panel. Once the zone is secured, it
gramming before the system can be armed.                                 will be monitored by the system. This zone attribute, for
                                                                         example, will allow the user to arm the system with the
NOTE: Wireless zones should not be programmed as zone
                                                                         garage door open. Later, when the door is closed, it will be
types [22] - [24].
                                                                         armed along with the rest of the system. Do not program
[22] Momentary Keyswitch Arm Zone                                        this attribute for 24Hr zones.
Momentary violation of this zone will alternately arm/disarm             The Force Arm attribute is not recommended for UL
the system.                                                              installations.
16
                                                   P r o g r a m       D e s c r i p t i o n s :       5. 4    A s s ig n in g       K e y p a d      Z o ne s
• Swinger Shutdown Enable – This attribute determines                          NOTE:Contact your local telephone company to confirm which
    whether or not the panel will shut down the communicator                   settings should be used.
    and bell for a zone once its swinger limit has been
    reached. (See 5.19 “Swinger Shutdown” on page 24.)                         DTMF or Pulse Dialing . . . . . . . . . . . . . . . . .Section [380]: [3]
• Transmission Delay Enable – This attribute determines                        Switch to Pulse Dialing on Fifth Attempt . . .Section [380]: [4]
    whether or not the panel will delay communicating the alarm                Communicator Enable/Disable . . . . . . . . . .Section [380]: [1]
    reporting code for the programmed Transmission Delay                       Communicator Call Direction Options . . . Section [361]-[368]
    Period. (See 5.15 “Transmission Delay” on page 23.)                        Busy Tone Detection . . . . . . . . . . . . . . . . . .Section [701]: [6]
• Wireless Zone – This attribute determines which zones                        Maximum Dialing Attempts . . . . . . . . . . . . . . . . Section [160]
    are to have wireless devices. This allows the panel to gen-                Post Dial Wait for Handshake . . . . . . . . . . . . . . Section [161]
    erate a low battery trouble and zone supervisories for the
    wireless zones.                                                            5.6       Communicator – Account Numbers
NOTE: Any zone with the wireless attribute enabled will not                    The account number is used by the central station to distin-
cause an alarm for a fault condition when armed (or any time                   guish between panels. There are two account numbers pro-
for 24-hour zones).                                                            grammable for the PC580.
Zone Attributes . . . . . . . . . . . . Sections [101] - [108]: [1] - [8]      First Account Code (4 digits). . . . . . . . . . . . . . . Section [310]
                                                                               Second Account Code (4 digits) . . . . . . . . . . . Section [311]
5.4      Assigning Keypad Zones
“Z” keypads have zone inputs to which devices—such as                          5.7       Communicator – Telephone Numbers
door contacts—can be connected. (See 2.11 “Keypad Zones”                       The panel can use three different telephone numbers for com-
on page 6 for wiring information.)                                             municating with the central station. The First Telephone
Once the keypad zones are installed, assign the zone in pro-                   Number is the primary number, the Second Telephone Num-
gramming section [020] Keypad Zone Assignments.                                ber is the secondary number and the Third Telephone Num-
Enter the 2 digit zone designated for each keypad (slot) from                  ber will back up the First telephone number if enabled.
01-08.                                                                         NOTE:The Third Telephone Number will NOT back up the Sec-
                                                                               ond Telephone Number.
Keypad Zone Assignments . . . . . . . . . . . . . . . . . . . . . . [020]
                                                                               NOTE: If you enter a telephone number section (sections [301]
                                                                               - [303]) at an LED keypad, pressing [#] will delete the pro-
5.5      Communicator – Dialing                                                grammed telephone number and change all the digits to [F].
If the Communicator Disable option is selected, the panel
                                                                               If the Alternate Dial option is enabled, the panel will alternate
will not attempt to call central station. If communication is
                                                                               between the first and third telephone numbers when attempt-
enabled, the panel will attempt to call central station when an
                                                                               ing to call the central station. If the option is disabled, the
event with a valid reporting code occurs. (See 5.8 “Communi-
                                                                               panel will only attempt to call the Third telephone number after
cator – Reporting Codes” on page 18.)
                                                                               failing to communicate with the first telephone number.
The Communicator Call Direction options are used to select
which telephone number the panel will dial when an event                       NOTE:To use the Third Telephone Number, you must enable it
occurs.                                                                        in section [380], option [5], and program it in section [303].
If the DTMF Dialing option is enabled, the panel will dial using               NOTE:Telephone numbers can be up to 32 digits. This allows
DTMF (touch tone). If the Switch to Pulse Dial option is                       you to add special digits if required. To program the telephone
enabled, the panel will switch to pulse dialing on the fifth                   number, enter the numbers 0 through 9 as required. The fol-
attempt to call the central station. When this option is dis-                  lowing is a list of programmable HEX digits and the functions
abled, the panel will always dial using DTMF. If DTMF Dialing                  they perform:
is disabled, the panel will always pulse dial.                                 HEX (B) - simulates the [*] key on a touch tone telephone
If the Busy Tone Detection option is enabled, the panel will                   HEX (C) - simulates the [#] key on a touch tone telephone
hang up after detecting busy tone for 5 seconds and will
                                                                               HEX (D) - forces the panel to search for dial tone
redial after the amount of time programmed in the Delay
Between Dialing Attempts section.                                              HEX (E) - forces the panel to pause for 2 seconds
Maximum Dialing Attempts determines the maximum num-                           HEX (F) - marks the end of the telephone number
ber of attempts the panel will make to send a signal to the                    NOTE:The first digit of all telephone numbers must be the HEX
central station before indicating a Failure to Communicate                     digit ‘D’ for dial tone search, or HEX digit ‘E’ for a two-second
(FTC) trouble condition. The 3rd Telephone Number can be                       pause.
used to back up the 1st in this situation. (See 5.7 “Communi-
cator – Telephone Numbers” on page 17.) If a later communi-                    First Telephone Number. . . . . . . . . . . . . . . . . . . Section [301]
cation attempt is successful, the FTC reporting code(s)                        Second Telephone Number . . . . . . . . . . . . . . . . Section [302]
programmed in section [351] will be transmitted along with the                 Third Telephone Number . . . . . . . . . . . . . . . . . . Section [303]
unreported events from an earlier unsuccessful communica-                      Third Telephone Number Enable . . . . . . . . .Section [380]: [5]
tion.                                                                          Alternate Dial . . . . . . . . . . . . . . . . . . . . . . . .Section [380]: [6]
Post Dial Wait for Handshake determines the amount of time
the panel will wait for a valid handshake from the receiver. If
the panel does not hear the handshake it will consider the call
a failed attempt, hang up and try again.
                                                                                                                                                             17
5.8      Communicator – Reporting Codes                                       access code, if one is programmed for the Key, regardless of
The panel can be programmed to report events to the central                   this option.
station by sending the Reporting Code programmed for a                        AC Failure Trouble Alarm Code
particular event.                                                             To prevent the panel from transmitting an AC Failure Trouble
Reporting codes can be one or two digits and can use HEX                      Alarm reporting code during short power outages, the panel
digits (A through F). For a complete description of reporting                 will not send the signal unless AC power is lost for the amount
codes which can be programmed and lists of automatic Con-                     of minutes programmed for the AC Failure Communication
tact ID and SIA format codes, please see Appendix A:                          Delay. The AC Failure Trouble Restoral reporting code follows
“Reporting Codes” on page 42.                                                 the AC failure communication delay as well.
NOTE:Do not use the digit C in a reporting code when using                    NOTE:If AC Failure Communications Delay is programmed as
Pager Format. In most cases, the digit C will be interpreted as               “000,” then the AC failure transmission will be immediate.
a [#], which will terminate the page before it has finished.
                                                                              AC Failure Communication Delay . . . . . . . . . . . Section [370]
Reporting Codes . . . . . . . . . . . . . . . . . Section [320] to [353]
                                                                              Wireless Maintenance
Cross Zone Police Reporting Code                                              The panel will transmit a Wireless Device Low Battery Alarm
The Cross Zone Police Code Alarm will be sent when two                        reporting code if a low battery condition is indicated by a
different alarms occur during any armed-to-armed period.                      detector. The transmission of the trouble will be delayed by
When an alarm occurs while the panel is armed and a second                    the number of days programmed for Zone Low Battery
alarm occurs on a different zone during the same armed                        Transmission Delay. The Wireless Device Low Battery Resto-
period, or after the system is disarmed, this code will be sent.              ral reporting code will be transmitted when the problem is cor-
All zone types contribute to this alarm. The cross zone police                rected. The specific zone that caused the trouble will be
code will be transmitted immediately unless either or both                    recorded in the event buffer.
zones have the Transmission Delay attribute enabled. If so,                   NOTE: The restoral will not be transmitted until all detectors
the code will be delayed for the programmed transmission                      indicate good battery conditions.
delay time.
Cross Zone Police Code Alarm . . . . . . . . . . . . Section [328]            Wireless Maintenance Reporting Codes . . . . . Section [353]
                                                                              Wireless Device Battery Transmission Delay . . Section [370]
Zone Restorals
If the Restoral on Bell Time-out option is selected, the panel                Arming and Activity Delinquency
will send the Zone Restoral Reporting Code for the zone if                    When Delinquency Follows Arming (Days) is selected, the
the bell cut-off time has expired and the zone is secured. If the             Delinquency reporting code is sent whenever the panel is not
zone is not secured when the bell cut-off time expires, the                   armed within the number of days programmed for the Delin-
panel will send the restoral immediately once the zone is                     quency Transmission Cycle.
secured, or when the system is disarmed. If the Restoral on                   NOTE: If the Delinquency Transmission Cycle is set for one
Bell Time-out option is not selected, the panel will immediately              day, there must be 24 hours of no arming or disarming before
send the Zone Restoral Reporting Code when the zone is                        the Delinquency Code will be sent. After a Delinquency Code
secured, regardless of whether or not the alarm output is                     has been transmitted, it will not be sent again until the system
active.                                                                       has been armed and disarmed.
NOTE:24 Hour type zones will report the restoral immediately                  When Delinquency Follows Zone Activity (hours) is
when the zone is secured.                                                     enabled, if there is no activity on zones in the system, the
                                                                              Delinquency Transmission Cycle Timer in Section [370] will
Restoral on Bell Time-out . . . . . . . . . . . . . . Section [380]: [2]      begin counting in hours. When the counter reaches the pro-
                                                                              grammed time, the panel will communicate the Delinquency
Closings (Arming Codes)                                                       reporting code to the central station, if programmed. If there
If the Closing Confirmation option is enabled, once the exit                  is a closing or zone activity present on the system at any time,
delay expires, the keypad will sound a series of eight beeps to               the counter will be reset.
confirm to the user that the closing code was sent and                        NOTE:Activity Delinquency will not be reported while the panel
received by the central station.                                              is armed in Away mode.
Closing Confirmation . . . . . . . . . . . . . . . . . . Section [381]: [4]   NOTE:Activity on manually bypassed zones will not reset the
                                                                              timer.
Openings/Closings by Wireless Key                                             NOTE:This timer is reset when the panel is armed, or if
If you are using a PC5132 v3.0 or higher, wireless keys with                  Installer Programming is entered.
access codes may be identified when they are used to arm or
disarm the system: the panel will log and transmit opening or                 NOTE:When using the SIA FSK communication format with
closing by access code (the same as if an access code had                     Activity Delinquency, the Closing Delinquency identifier is
been used to arm/disarm the system). If wireless keys with no                 transmitted.
access code are used, the event will be logged and transmit-
ted as opening or closing by keyswitch.                                       Miscellaneous Maintenance Reporting Codes. Section [351]
The Function Keys Require Code option must be selected                        Delinquency Follows Zone Activity . . . . . . . . . . . . . .[380]: [8]
(section [015], option 4 OFF) in order for wireless keys to be                Delinquency Transmission Cycle . . . . . . . . . . . . . . . . . . [370]
identified for arming. Disarming will always be logged by
18
                           P r o g r a m    D e s c r i p t i o n s :   5. 9   C o m m un ic a t or    –   R e p o rt i ng   F or m a t s
5.9     Communicator – Reporting Formats                                NOTE:If the Automatic Contact ID option is selected, the panel
Each communication telephone number can be programmed                   will automatically generate all zone and access code numbers,
to report using any one of eight formats available. Two 20              eliminating the need to program these items.
BPS pulse formats are supported, in addition to Contact ID,             If the Contact ID uses Programmed Reporting Codes
SIA and Pager formats.                                                  option is enabled, the panel will operate as follows:
The Communicator Call Direction options can be used to                  1. If an event’s reporting code is programmed as [00] or [FF],
disable the reporting of events such as Openings and Clos-                  the panel will not attempt to call central station.
ings.                                                                   2. If the reporting code for an event is programmed as any-
NOTE: Do not program the 2nd telephone number to use Con-                   thing from [01] to [FE], the panel will send the programmed
tact ID or SIA reporting code formats (section [360]) if Auto-              reporting code.
matic reporting codes are selected for either Contact ID or SIA         Additional Notes on Contact ID
(section [381]).                                                        1. Account numbers must be four digits.
                                                                        2. All reporting codes must be two digits.
Communicator Format Options . . . . . . . . . . . . Section [360]       3. Substitute the HEX digit ‘A’ for the ‘0’.
Communicator Call Directions . . . . . . . Section [361] to [368]       4. To prevent the panel from reporting an event, the reporting
                                                                           code should be programmed as [00].
The following is a description of each reporting format:
                                                                        Please refer to Appendix A: “Reporting Codes”for a list of
Pulse Formats                                                           Contact ID Identifiers.
Depending on which pulse format is selected, the panel will
communicate using the following specifications:                         Contact ID Uses Programmed/Automatic Codes . . [381]: [7]
• 3/1, 3/2, 4/1 or 4/2
• 1400 or 2300 Hz handshake                                             SIA
• 20 bits per second                                                    SIA is a specialized format that will communicate information
                                                                        quickly using Frequency Shift Keying (FSK) rather than
• non-extended
                                                                        pulses. The SIA format will automatically generate the type of
Additional Notes on Pulse Formats
                                                                        signal being transmitted, such as Burglary, Fire, Panic etc.
1. The digit ‘0’ will send no pulses and is used as a filler digit.     The two digit reporting code is used to identify the zone or
2. When programming account numbers, enter four digits.                 access code number.
   When programming a three digit account number, the
                                                                        NOTE: If the Automatic SIA option is selected, the panel will
   fourth digit must be programmed as ‘0’.
                                                                        automatically generate all zone and access code numbers,
   3 digit account number [123] - program [1230]
3. If an account number has a ‘0’ in it, substitute a HEX digit         eliminating the need to program these items.
   ‘A’ for the ‘0’. For example:                                        If the SIA Sends Automatic Reporting Codes option is
   3 digit account number [502] - program [5A20]                        enabled, the panel will operate as follows:
   4 digit account number [4079] - program [4A79]                       1. If an event’s reporting code is programmed as [00], the
4. Reporting codes are two digits. When programming sin-                    panel will not attempt to call the central station.
   gle-digit Reporting Codes, the second digit must be pro-             2. If the reporting code for an event is programmed as any-
   grammed as a ‘0’. If a ‘0’ is to be transmitted, substitute              thing from [01] to [FF], the panel will automatically gener-
   HEX digit ‘A’. For example:                                              ate the zone or access code number.
   1 digit Reporting Code [3] - program [30]                            If the SIA Sends Programmed Reporting Codes option is
   2 digit Reporting Code [30] - program [3A]                           enabled, the panel will operate as follows:
5. To prevent the panel from reporting an event, the reporting          1. If an event’s reporting code is programmed as [00] or [FF],
   code should be programmed as [00] or [FF].                               the panel will not attempt to call central station.
Contact ID                                                              2. If the reporting code for an event is programmed as any-
Contact ID is a specialized format that will communicate infor-             thing from [01] to [FE], the panel will send the programmed
mation using tones rather than pulses. This format allows more              reporting code.
information to be sent faster than other formats. For example,          Please refer to Appendix A: “Reporting Codes”for a list of SIA
in addition to reporting an alarm in zone one, the Contact ID           identifiers.
format will also report the type of alarm, such as an Entry/Exit
                                                                        SIA Sends Automatic Reporting Codes. . . .Section [381]: [3]
alarm.
If the Contact ID uses Programmed Reporting Codes                       Pager Format
option is enabled, a two digit number from Appendix A must              The Communicator Format option for either telephone number
be entered in programming sections [320] to [353] for each              can be programmed as Pager format. If an event occurs and
event to be transmitted. The two digit number determines the            the Communicator Call Direction options direct the call to a
type of alarm. The panel will automatically generate all other          telephone number with the Pager Format selected, the panel
information, including the zone number.                                 will attempt to page.
If the Contact ID uses Automatic Reporting Codes option is              When calling a pager, extra digits will be required in order for
enabled, the panel will operate as follows:                             the format to function properly. The following is a list of Hex
1. If an event’s reporting code is programmed as [00], the              digits and the functions they perform:
     panel will not attempt to call the central station.                Hex [B] - simulates the [*] key on a touch tone telephone
2. If the reporting code for an event is programmed as any-
                                                                        Hex [C] - simulates the [#] key on a touch tone telephone
     thing from [01] to [FF], the panel will automatically gener-
     ate the zone or access code number. See Appendix A for a           Hex [D] - forces the panel to search for dial tone
     list of the codes which will be transmitted.                       Hex [E] - two second pause
                                                                        Hex [F] - marks the end of the telephone number
                                                                                                                                      19
The panel will attempt to call the pager once. Once the appro-      Local Downloading via the PC-LINK, enter [*][8][Installer’s
priate telephone number is dialed, the panel will send the          Code][499][Installer’s Code][499]. All keypads will be busy for
account number and Reporting Code followed by the [#] key           the duration of the PC-LINK connection. The status LEDs will
(Hex [C]).                                                          display the current system status on the keypad where the
The panel has no way of confirming if the pager was called          PC-LINK was initiated. For more information on connecting the
successfully. A Failure To Communicate trouble will only be         PC-LINK, refer to your “PC-LINK Download Kit Instruction
generated if the panel detects a busy tone on all dialing           Sheet”.
attempts, or if no dial tone is detected on all dialing attempts.   NOTE: When a zone status upload is performed through PC-
The pager format will not cause any form of ringback.               LINK, the information uploaded may not be accurate. For more
NOTE:The Pager Format cannot be used with the LINKS1000             information, refer to your DLS-1 manual.
cellular communicator.                                              Downloading can also be performed through the LINKS1000
NOTE:Do not use the digit C in a reporting code when using          cellular communicator if the telephone line is disconnected. If
Pager Format. In most cases, the digit C will be interpreted as     using the LINKS1000 with call back, you need to program the
a [#], which will terminate the page before it has finished.        LINKS1000 Preamble with the downloading telephone num-
                                                                    ber in order for the panel to call the computer correctly.
NOTE:If the panel detects a busy signal, it will attempt to page
again. It will make the maximum number of attempts pro-             NOTE:When uploading labels from LCD keypads, only labels
                                                                    from the LCD keypad assigned to slot 8 will be uploaded.
grammed in section [160].
NOTE:Force dialing should be disabled when using Pager for-         Answering Machine/Double Call . . . . . . . . Section [401]: [1]
mat.                                                                User Enable DLS Window . . . . . . . . . . . . . Section [401]: [2]
NOTE:When using Pager format, you must program two hex              Call-Back . . . . . . . . . . . . . . . . . . . . . . . . . . Section [401]: [3]
digit E’s at the end of the telephone number                        User-initiated Call-up enabled/disabled . . . Section [401]: [4]
                                                                    Downloading Computer’s Telephone Number . Section [402]
5.10 Downloading                                                    Downloading Access Code . . . . . . . . . . . . . . . Section [403]
The required downloading software is DLS-1 v6.7 and up.             Panel Identification Code . . . . . . . . . . . . . . . . . Section [404]
Downloading allows you to program the entire control panel          Answering Machine Double Call Timer . . . . . . Section [405]
via a computer, a modem and a telephone line. All functions,        Number of Rings to Answer On . . . . . . . . . . . . Section [406]
features, their changes and status – such as trouble condi-         LINKS1000 Preamble (Downloading) . . . . . . . . Section [490]
tions and open zones – can be viewed or programmed                  Initiate Local Downloading (PC-LINK) . . . . . . . Section [499]
through downloading.
NOTE:Downloading is always enabled for six hours each time          5.11 PGM Output Options
the panel is powered up, unless the User Can Enable DLS             Program the programmable outputs PGM1 and PGM2 on the
Window option is disabled                                           main board by selecting one of the output options listed below
The panel will answer calls for downloading when the pro-           (exceptions noted).
grammed Number of Rings is heard by the panel.                      Main Board PGM Outputs. . . . . . . . . . . . . . . . . Section [009]
If the Answering Machine/Double Call option is enabled (or
during the first six hours after power up), the panel will answer   NOTE: PGM outputs cannot be completely disabled in
incoming calls for downloading in the following manner:             installer’s programming. To disable a PGM output completely,
1. The panel hears one or two rings then misses a ring.             you must remove all wiring from the output.
2. At this point the panel will start a the double-call timer.
                                                                    [01] Burglary and Fire Bell Output
3. If the panel hears another ring before the Answering
                                                                    The output will activate when the alarm output is active and
     Machine Double-Call Timer expires, it will answer on the
                                                                    will deactivate when the alarm output is silenced. If the alarm
     first ring of the second call.
                                                                    output is pulsing, the PGM output will pulse as well. This out-
The panel will immediately go on line and begin downloading.
                                                                    put will follow the activation of the alarm output (pre-alert) for
If the Call-Back option is enabled, the panel and the com-
                                                                    delayed fire zones.
puter will both hang up. The panel will then call the Down-
loading Computer’s Telephone Number and wait for the                [02] For future use
computer to answer. Once the computer answers, download-            [03] Sensor Reset ([*][7][2])
ing will begin.                                                     NOTE:This output will normally be active (switched to ground).
If the User Enabled DLS Window option is ON, the user can
                                                                    This option is used to reset power for latching smoke detec-
activate the downloading feature by entering [*][6][Master
                                                                    tors. The output will deactivate for five seconds when the
Code][5].
                                                                    [*][7][2] command is entered. (See “[*][7] Command Output
If the User Initiated Call-Up option is enabled, the user can       Functions” on page 11.) The keypad buzzer will not sound for
have the panel initiate a call to the downloading computer by       the five second period.
pressing [*][6][Master Code][6].
                                                                    Please refer to the Control Panel Wiring Diagram in this man-
The Download Access Code and Panel Identifier Code are              ual for wiring instructions.
for security and proper identification. Both the panel and the
                                                                    NOTE:Only ONE of options [03] Sensor Reset and [20] [*][7][2]
computer file should contain the same information pro-
grammed before attempting to download.
                                                                    Command Output Option #2 may be programmed on the same
                                                                    system.
The time to complete a successful download can be signifi-
cantly reduced with the use of the PC-LINK. This adaptor
makes it possible to perform on-site downloading. To Initiate
20
                                                  P r o g r a m       D e s c r i p t i o n s :      5 . 11     P G M     O u t pu t     O pt i o ns
[04] For future use                                                       Program which events will activate the output by selecting
[05] Armed Status                                                         some or all of the following attributes:
When the system is armed, the PGM output will activate at the             Attribute
beginning of the exit delay. The output deactivates when the                 [1] .........Burglary (Delay, Instant, Interior, Stay/Away and
system is disarmed.                                                                       24 Hour Burglary Zones)
[06] Ready To Arm                                                            [2] .........Fire (Fire Keys, Fire Zones)
The PGM will be active as long as the system is ready to arm                 [3] .........Panic (Panic Keys and Panic Zones)
and all non-force armable zones on the system are restored.                  [4] .........Medical (Auxiliary Keys, Medical and Emergency
Once an access code is entered to arm the system and the                                  Zones)
exit delay begins, the PGM output is deactivated.                            [5] .........Supervisory (Supervisory, Freezer and Water
[07] Keypad Buzzer Follower Mode                                                          Zones)
The PGM will activate when any of the following events occur                 [6] .........Priority (Gas, Heat, Sprinkler and 24 Hour Latch-
and will remain active for as long as the keypad buzzer is                                ing Zones)
active:                                                                      [7] .........Holdup (Holdup zones)
• Door Chime                       • Entry Delay                             [8] .........Output Follows Timer (output will activate for the
• Auto-Arm Prealert                • Audible Exit Delay                                   number of seconds programmed in the PGM Out-
• 24 Hour Supervisory Buzzer Zone                                                         put Timer) / Output Latched
[08] Courtesy Pulse                                                       NOTE:If attribute [8] is turned ON, attributes [1-7] must also be
Upon arming, the PGM output will activate for the duration of             turned ON.
the exit delay plus an additional two minutes. Upon disarming,
the PGM output will activate for the duration of the entry delay          PGM Output Timer . . . . . . . . . . . . . . . . . . . . . . . Section [164]
plus an additional two minutes.
                                                                          [11] System Tamper (All Sources)
[09] System Trouble Output                                                The PGM output will activate when any tamper condition is
The PGM output will activate when any of the selected trouble             present and will deactivate when all tampers are restored.
conditions are present. It will deactivate when all the selected
trouble conditions are cleared.                                           [12] TLM and Alarm
                                                                          The PGM output activates when the system experiences both
The PGM attributes for this option, programmed in Sections
                                                                          a telephone line trouble and an alarm. When the system is
[141] to [142], differ from the standard selection of attributes.
                                                                          armed, the output will deactivate only if an access code is
Program which trouble conditions will activate the output by
                                                                          entered or if the telephone line is restored.
selecting some or all of the following attributes:
                                                                          If an alarm activates this output in the disarmed state, the out-
Attribute                                                                 put will deactivate if a user enters a valid access code while
   [1] .......... Service Required (battery, bell, general trouble,       the Bell Cut-off timer is counting down, or if the telephone line
                  general tamper, general supervisory)                    is restored. The output will also deactivate if someone arms
   [2] .......... AC Failure                                              the system after the Bell Cut-off has expired.
   [3] .......... Telephone Line Trouble                                  NOTE:This output will activate for all silent and audible alarms
   [4] .......... Failure to Communicate                                  except the Duress alarm.
   [5] .......... Fire Trouble / Zone Fault
                                                                          [13] Kissoff Output
   [6] .......... Zone Tamper
                                                                          The output will activate for two seconds after the control panel
   [7] .......... Zone Low Battery
                                                                          receives the kissoff transmission from the central station.
   [8] .......... Loss of Clock
                                                                          [14] Ground Start Pulse
[10] System Event (Strobe Output)                                         The PGM Output will activate for two seconds to obtain a dial
The output activates when any of the selected system events               tone on Ground Start telephone equipment before the panel
(alarms) occur on the system.                                             attempts to dial. Insert two 2-second pauses at the beginning
NOTE:This output will activate for silent and audible alarms or           of the telephone number when using this option.
medical conditions only. It will not activate during pre-alert or         [15] Remote Operation (DLS-1 Support)
delays.                                                                   This output can be activated and deactivated remotely using
If attribute [8] is turned ON, the output will activate for the           the DLS software.
number of seconds programmed in the PGM output timer                      [16] LINKS1000 Support (PGM1 Only)
(section [164]).                                                          The PGM output will be used as a data wire to communicate
If attribute [8] is turned OFF, in the armed state, the output will       telephone number information for the LINKS1000 cellular unit.
deactivate only once the system is disarmed. If an alarm acti-
                                                                          [17] Away Armed Status
vates this output in the disarmed state, the output will deacti-
                                                                          When the system is armed in the Away mode, the PGM output
vate if a user enters a valid access code while the Bell Cut-off
                                                                          will activate at the beginning of the exit delay. The output
timer is counting down. The output will also deactivate if
                                                                          deactivates when the panel is disarmed.
someone arms the system after the Bell Cut-off has expired.
This output can be used to indicate that an alarm has                     [18] Stay Armed Status
occurred before entering the premises.                                    When the system is armed in the Stay mode, the PGM output
                                                                          will activate at the beginning of the exit delay. The output
The PGM attributes for this option, programmed in Sections
                                                                          deactivates when the panel is disarmed.
[141] to [142], differ from the standard selection of attributes.
                                                                                                                                                    21
[19] [*][7][1] Command Output Option #1                                 5.12 Telephone Line Monitor (TLM)
[20] [*][7][2] Command Output Option #2                                 When the TLM Enable option is selected, the panel will super-
These outputs are user-initiated by entering [*][7][1-2] at any         vise the telephone line and will indicate a trouble condition if
keypad. When any output is activated, three acknowledgment              the telephone line is disconnected.
beeps are sounded.                                                      If the TLM Enable option is ON, the panel will check the tele-
NOTES on Option [20] [*][7][2]:                                         phone line every 10 seconds. If the telephone line voltage is
Press [*][7][2][Access Code, if required] to activate any out-          below 3V for the number of checks programmed in the TLM
put programmed as one of PGM output option [03] or [20].                Trouble Delay section, the panel will report a TLM trouble.
Traditionally, [*][7][2] has been reserved for resetting smoke          The default number of checks is 3. Enter a number from [003]
detectors. Smoke detectors should now be programmed as                  to [255] in the TLM Trouble Delay section to change the num-
output [03] “Sensor Reset”.                                             ber of checks before the TLM trouble is reported. Program-
                                                                        ming a delay means that a momentary interruption of the
NOTE:Only ONE of options [03] Sensor Reset and [20] [*][7][2]           telephone line will not cause a trouble condition.
Command Output Option #2 may be programmed on the same
                                                                        If the TLM Trouble Beeps When Armed option is enabled,
system.
                                                                        the panel will indicate a TLM trouble at the keypad while the
[21]-[24] For future use                                                system is armed. To activate the bell output in the case of a
PGM Output Attributes                                                   TLM trouble while the system is armed, the TLM Audible
In addition to programming the output type, you must also               (Bell) When Armed option must be selected.
program the PGM output attributes for each output.                      When the trouble condition is restored, the panel can send a
PGM output options [09] “System Trouble” and [10] “System               TLM Restoral reporting code. Any events which occur while
Event” have their own unique set of attributes listed below the         the telephone line is down will also be communicated.
description of each output type.                                        If the LINKS1000 Cellular Communicator, Skyroute transceiver,
PGM output options [01], [03], [05]-[08], [11]-[20] have the            or LINKS2X50 is being used, the panel can be programmed to
following attributes:                                                   report a TLM Trouble Reporting Code.
Attribute.... ON                       OFF                              TLM Enable/Disable . . . . . . . . . . . . . . . . . . Section [015]: [7]
     [1] ....... PGM Enable            PGM Disable                      TLM Trouble Beeps When Armed or
     [3] ....... True Output           Inverted Output                  TLM Audible (Bell) When Armed . . . . . . . . Section [015]: [8]
                 Attribute ON: the output energizes when activated      TLM Trouble Reporting Code . . . . . . . . . . . . . . Section [349]
                 Attribute OFF: the output de-energizes when acti-      TLM Restoral Reporting Code . . . . . . . . . . . . . Section [350]
                 vated                                                  TLM Trouble Delay . . . . . . . . . . . . . . . . . . . . . . Section [370]
     [4] ....... Output Pulsed         Output ON/OFF
                 Attribute ON: the output will activate once for the
                                                                        5.13 Bell
                 amount of time programmed in section [164]
                                                                        The bell will silence after the number of minutes programmed
                 when initiated by the user
                                                                        for the Bell Cut-off time have passed.
                 Attribute OFF: the output will toggle ON or OFF
                 when initiated by the user.                            The panel supervises the Bell output. If an open condition is
                 (Only applicable to options [19]-[20].)                detected, the panel will immediately indicate a trouble condi-
                                                                        tion by beeping the keypad twice every 10 seconds to alert
     [5] ....... Access Code Req. No code Req.
                                                                        the owner of the problem. The panel can send a Bell Circuit
                 Attribute ON: the output requires a code for acti-
                                                                        Trouble and Trouble Restoral reporting codes to indicate the
                 vation.
                                                                        situation (See 5.8 “Communicator – Reporting Codes” on
                 Attribute OFF: no code required.
                                                                        page 18.)
                 (only applicable to keypad-activated outputs)
                                                                        If the Temporal Three Fire Signal option is enabled, all Fire
PGM attributes return to their default settings when you
                                                                        signals (on zone types [07], [08], [87], [88]) will follow the
change PGM output options. Please see the programming
                                                                        Temporal Three Pattern as described in NFPA 72. If turned
worksheets for a list of the default settings for each PGM out-
                                                                        OFF all Fire signals will sound a one second on, one second
put type.
                                                                        off cadence.
Be careful when selecting the normal and active states of
                                                                        If Fire Bell Continuous is enabled, the alarm output will
each PGM output to ensure that an undesirable output state
                                                                        sound until a code is entered. If disabled, the alarm will sound
does not occur after a loss and restore of AC power.
                                                                        until a code is entered or the bell cut-off time has expired.
NOTE: Attribute [3] must be ON (default) for PGM output
option [16].                                                            Bell Cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [005]
NOTE: If you program more than one PGM output as the same               Bell Circuit Trouble Reporting Code . . . . . . . . . Section [349]
output type (e.g. if PGM1 and PGM2 are both programmed as               Bell Circuit Trouble Restoral Reporting Code . . Section [350]
[19] Command Output 1), the settings for output attributes [1],         Temporal Three Fire Signal Enable/Disable Section [013]: [8]
[2] and [5] must be the same. This does not apply to outputs            Fire Bell Continuous . . . . . . . . . . . . . . . . . . Section [014]: [8]
programmed as types [09] and [10].
                                                                        5.14 Test Transmission
PGM Output Attributes . . . . . . . . . . . . . . Section [141]-[142]   To ensure that the communication link with the central station
                                                                        is functioning properly, program the panel to send a test trans-
                                                                        mission signal on a regular basis.
22
                                                         P r o g r a m     D e s c r i p t i o n s :        5 . 1 5    T r a n sm i ss io n        D e l a y
The panel can send a Periodic Test Transmission Reporting                    NOTE:The Fire, Auxiliary, Panic keys will operate even if Key-
Code at the programmed Test Transmission Time of Day.                        pad Blanking is active (See 5.22 “Keypad Blanking” on page
The Test Transmission Cycle determines the period of time                    24.)
between tests.
NOTE:The LINKS Test Transmission can only be programmed                      [F] Key Enable . . . . . . . . . . . . . . . . . . . . . . .Section [015]: [1]
in days.                                                                     [P] Key Audible Bell and Buzzer . . . . . . . . .Section [015]: [2]
If you program the test transmission cycle for a longer period
of time than it was programmed for previously, the system will               5.17 Arming/Disarming Options
wait the original time period before the next test transmission              If the Quick Arm option is enabled, the panel can be armed
is sent, and then begin reporting with the new interval.                     without an access code by entering [*][0] or by pressing the
The panel can also send a test for the LINKS1000 Cellular                    Stay or Away function key. If the Quick Arm option is disabled,
Communicator, if used. If the LINKS1000 Test Transmission                    users will need to enter an access code after pressing a func-
Code is programmed, the panel will send a cellular test at the               tion key.
interval programmed in the LINKS Test Transmission Cycle.                    The Quick Exit option, if enabled, will allow someone to leave
Users can also generate a communicator test. If the System                   an armed premises through a Delay type zone without having
Test Reporting Code is programmed, the panel will send the                   to disarm and re-arm the system. See “[*][0] Quick Exit” on
signal when the System Test keypad command is entered.                       page 11.
(See “[*][6] User Functions” on page 10.)                                    Enable the Arm/Disarm Bell Squawk option to have the
                                                                             panel squawk the alarm output once upon arming and twice
Test Transmission Reporting Codes. . . . . . . . . Section [352]             upon disarming. If an alarm is in memory, when the panel is
Test Transmission Time of Day . . . . . . . . . . . . . Section [371]        disarmed the bell will sound three pairs of disarm squawks.
Test Transmission Cycles . . . . . . . . . . . . . . . . . Section [370]
                                                                             NOTE: If you enable the Bell Squawk on Arming/Disarming
                                                                             (section [014], option [1]), the bell will sound arm/disarm bell
5.15 Transmission Delay                                                      squawks for all access codes, regardless of the programming
If the transmission delay zone attribute is selected for a given             for attribute [7]. See “[*][5] Programming Access Codes” on
zone, the panel will delay reporting an alarm for that zone for              page 10.
the number of seconds programmed for the Transmission                        Enable both the Squawk on Away Arming/Disarming Only
Delay Time. If the panel is disarmed before the delay time                   and the Arm/Disarm Bell Squawk options to have the panel
expires, the panel will not report the event.                                squawk the bell only when the system is away armed or dis-
Transmission Delay Time . . . . . . . . . . . . . . . . . Section [370]      armed.
                                                                             The Opening After Alarm Keypad Ringback option will
                                                                             cause the keypad to beep 8 times rapidly after the Opening
5.16 Fire, Auxiliary and Panic Keys                                          After Alarm reporting code has been successfully transmitted
The emergency keys are available on all keypads. These keys                  to the central station. The Opening After Alarm Bell Ring-
must be pressed and held for two seconds before they will                    back option will cause the panel to squawk the bell 8 times
activate. This two second delay is designed to help prevent                  rapidly after the Opening After Alarm reporting code has been
accidental activation.                                                       successfully transmitted to the central station.
If the [F] /   Key option is enabled, when the Fire keys are                 NOTE:If the panel is armed using the Stay function key, or by
pressed and held for two seconds, the panel will activate the                entering [*][9][access code], there will be no bell squawks dur-
alarm output following the option programmed in section                      ing entry and exit delays, except for the arm/disarm bell
[013]: [8] (see section 5.13 “Bell” on page 22). The alarm out-              squawks.
put will sound until a code is entered or until the bell cut-off
                                                                             Closing Confirmation, if enabled, will cause the keypad to
time expires. Communication of the signal to central station is
                                                                             beep 8 times rapidly after the closing reporting code has
immediate.
                                                                             been successfully transmitted to central station.
If the [A] /    Key is pressed and held for two seconds, the                 If the Bypass Status Displayed While Armed option is cho-
panel will sound the keypad beeps three times to verify acti-                sen, the Bypass light will be ON while the system is armed to
vation. The panel will beep the keypad ten times rapidly when                indicate that there are bypassed zones.
a kissoff is received, to verify communication to the central
                                                                             If you enable the WLS Key Does Not Use Access Codes
station.
                                                                             option, the disarm button will work on wireless keys which
If the [P] /   Key is pressed and held for two seconds, the                  have not been assigned access codes. Wireless keys can
panel will immediately communicate the signal to central sta-                only be assigned access codes when used with PC5132 v3.0
tion.                                                                        or higher.
If [P] Key Audible Bell and Buzzer option is enabled, when a                 To prevent disarming by wireless keys which don’t have
user presses the [P] /   key, the keypad will beep three times               access codes, disable this option. (Please see your PC5132
and the panel will activate the alarm output until an access                 manual for more information on programming wireless keys.)
code is entered or the bell cut-off expires. If the option is dis-           NOTE: This option must be enabled when using a PC5132
abled, the Panic alarm will be completely silent.                            v2.1 or earlier.
Each LCD keypad may be programmed to have the [F], [A], &
[P] keys enabled or disabled. Please refer to Appendix B:                    Quick Arm Enable . . . . . . . . . . . . . . . . . . . .Section [015]: [4]
“Programming LCD Keypads” on page 44.                                        Quick Exit Enable. . . . . . . . . . . . . . . . . . . . .Section [015]: [3]
                                                                             Arm/Disarm Bell Squawk . . . . . . . . . . . . . . .Section [014]: [1]
                                                                                                                                                          23
Squawk on Away Arm/Disarm Only. . . . . . . Section [017]: [8]                Bell Squawk Options. . . . . . . . . . . . . . Section [014]: [2] - [4]
Closing Confirmation . . . . . . . . . . . . . . . . . . Section [381]: [4]   Exit Delay Termination. . . . . . . . . . . . . . . . . Section [014]: [7]
Opening After Alarm Keypad Ringback . . . Section [381]: [1]
Opening After Alarm Bell Ringback . . . . . . Section [381]: [2]
                                                                              5.19 Swinger Shutdown
Bypass Status Displayed While Armed. . . . Section [016]: [7]
                                                                              The swinger shutdown feature is designed to prevent a “run-
Unident. Wkey Disarm Enabled . . . . . . . . . Section [017]: [1]
                                                                              away” communicator from tying up the central station. After
                                                                              the panel has communicated the programmed number of
5.18 Entry/Exit Delay Options                                                 transmissions for an event, it will no longer report that event
Two different Entry Delays can be programmed: the first entry                 until the swinger shutdown is reset. Different swinger shut-
delay will be enabled for Delay 1 type zones and the second                   down levels can be set for zone alarms, zone tampers and
for Delay 2 type zones. Only one Exit Delay can be pro-                       maintenance signals.
grammed.                                                                      By default, each Swinger Shutdown limit is set to [003]. The
NOTE:When the panel is armed, the entry delay will follow the                 panel will not send more than three signals for each zone until
entry delay time programmed for the delay zone which is vio-                  the swinger shutdown is reset.
lated first.                                                                  The Bell output will not be activated for alarms on zones that
                                                                              have exceeded the limit of alarms set in the Swinger Shut-
Users can restart the exit delay by pressing the Away key
                                                                              down counter.
while it is counting down. The system will not log the user who
re-started the exit delay, unless the Quick Arming Disabled/                  Swinger shutdown will be reset every day at midnight or when
Function Keys Require Code option is turned on (section                       the panel is armed. Once reset, the panel will again communi-
[015], option [4]).                                                           cate normally.
NOTE: If the system has been Stay armed or armed with no                      Swinger Shutdown . . . . . . . . . . . . . . . . . . . . . . Section [370]
entry delay ([*][9]) pressing the Away key will not start an exit
delay.
                                                                              5.20 Event Buffer
Upon arming, the panel will begin the exit delay. If the Audible              The panel will store the last 128 events which occurred on the
Exit Delay with Urgency option is enabled, the keypad will                    system. The Event Buffer will contain the name, time and
beep at one second intervals until the exit delay expires. The                date of each event, along with the zone number, access code
keypad will beep rapidly for the last 10 seconds of exit delay                number or any other information pertaining to the event.
to warn the user that the system is about to arm. If this option              If the Event Buffer Follows Swinger Shutdown option is
is disabled, the keypad will not beep during the exit delay.                  enabled, the event buffer will not store events after the
The Audible Exit Fault, as explained in Section 3.1, will notify              Swinger Shutdown level has been reached. This will prevent
the user if they failed to secure the premises upon arming.                   the panel from overwriting the entire buffer if a problem exists.
This option can be enabled or disabled according to the                       The event buffer can be viewed in three different ways: from
user’s needs.                                                                 an LCD keypad (see “[*][6] User Functions” on page 10)
For commercial applications, the Bell Squawk on Exit Delay                    printed on-site using the PC5400 printer module, or it can be
option may be enabled. The panel will squawk the alarm out-                   uploaded using DLS software.
put once every second when the exit delay is initiated and
three times per second for the last 10 seconds until the exit                 Event Buffer Follows
delay expires.                                                                Swinger Shutdown . . . . . . . . . . . . . . . . . . . Section [013]: [7]
Upon entry, if a Delay type zone is violated, the panel will
begin the entry delay. The keypad will emit a steady tone. The                5.21 Keypad Lockout Options
keypad will pulse the keypad sounder during the last 10 sec-
                                                                              The panel can be programmed to “lock out” keypads if a
onds to warn the user the system is about to go into alarm. If
                                                                              series of incorrect access codes are entered. Once the Num-
there was an alarm during the armed period, the keypad will
                                                                              ber of Invalid Codes Before Lockout limit has been reached,
pulse for the entire entry delay to warn the user of the previous
                                                                              the panel will lock out all keypads for the Lockout Duration
alarm.
                                                                              and log the event to the event buffer. For the duration of the
For commercial applications Bell Squawk on Entry Delay                        lockout, the panel will sound an error tone when any key is
may be enabled. The panel will squawk the alarm output once                   pressed.
every second until the entry delay expires or the system is dis-
                                                                              NOTE: The Invalid Code Counter will be reset every hour.
armed.
If the Bell Squawk During Auto Arm option is enabled, the                     To disable the keypad lockout option, program the Number of
bell will squawk once every 10 seconds for one minute during                  Invalid Codes Before Lockout as [000].
the Auto-arm pre-alert. This will notify anyone on the premises               NOTE: If Keypad Lockout is active, the panel CANNOT be
that the system is being armed.                                               armed / disarmed with a keyswitch.
If the Exit Delay Termination option is enabled, the panel will
monitor the Delay 1 zones during exit delay. During the exit                  Keypad Lockout Options . . . . . . . . . . . . . . . . . Section [012]
delay, if a Delay 1 type zone is violated and then secured, the
exit delay will be terminated and the panel will be armed                     5.22 Keypad Blanking
immediately.
                                                                              If the Blank Keypad When Not in Use option is enabled, the
Entry Delay 1 and 2 (System Times) . . . . . . . . . Section [005]            panel will turn off all lights and LCDs on the keypads when no
Exit Delay (System Times). . . . . . . . . . . . . . . . . Section [005]      keys are pressed for 30 seconds. The keys, however, will
Audible Exit Delay with Urgency . . . . . . . . . Section [014]: [6]          remain backlit.
Audible Exit Fault Enabled/ Disabled . . . . . Section [013]: [6]
24
                                                       P r o g r a m       D e s c r i p t i o n s :     5 . 2 3   K e y p a d    B ac k li gh t in g
The panel will turn the lights and LCDs back on if entry delay                 NOTE: If a LINKS1000 is connected to the system, make sure
begins or an audible alarm occurs. The lights and LCDs will                    the Maximum Number of Dialing Attempts is programmed to
also come on if a key is pressed or, if a valid access code is                 be 008 or greater (section [160].
entered when the Code Required to Restore Blanking
                                                                               Using LINKS1000 as the Sole Communicator
option is enabled.
                                                                               The panel can be programmed to report an event only using
NOTE:If using a PC5132 v3.0 or greater, and wireless keys, do                  the LINKS1000 cellular communicator. To program this option,
not enable the Code Required to Restore Blanking option, as                    select only the LINKS1000 in the Communicator Call Direction
the keys will not function correctly.                                          Options. The Call LINKS as well as Land Line option must also
If the Power Save Mode option is enabled the panel will blank                  be enabled.
all keypad lights including backlighting when AC power fails,                  When the selected event occurs the panel will only attempt to
in order to conserve the back up battery.                                      call central station using the LINKS.
                                                                               Using the LINKS1000 as a Backup Communicator
Blank Keypad when not in use. . . . . . . . . . Section [016]: [3]
                                                                               The panel can be programmed to call using the LINKS1000
Code Required to Restore Blanking. . . . . . Section [016]: [4]
                                                                               Cellular Communicator if the panel is having difficulty commu-
Power Save Mode . . . . . . . . . . . . . . . . . . . Section [016]: [6]
                                                                               nicating an event using the land line. To program this option,
                                                                               select both the telephone number and LINKS options in the
5.23 Keypad Backlighting                                                       Communicator Call Direction Options. The LINKS is Backup
The keys of all the keypads can be backlit to provide easy                     of Land Lines option must be selected.
viewing in dim lighting conditions. If the Keypad Backlighting                 When used as a backup communicator, the panel will attempt
option is enabled the keys will be illuminated.                                to call the central station in the following manner:
                                                                               the panel will try to call using land lines – if unsuccessful, the
Keypad Backlighting Option . . . . . . . . . . . Section [016]: [5]
                                                                               panel will try to call using the LINKS
                                                                               if unsuccessful, the panel will try to call using the land lines on
5.24 Loop Response                                                             the next dialing attempt
The normal loop response time for all zones is 500 millisec-                   This process will continue until the panel has successfully
onds. The panel will not consider a zone violated unless it is                 communicated with the central station or until the panel’s pro-
violated for at least 500 milliseconds.                                        grammed number of dialing attempts have been exhausted.
Zones 1-4 on the control board, however, can be programmed
                                                                               Using the LINKS as a Redundant Communicator
for a fast loop response (under 40ms).
                                                                               The panel can be programmed to call using first the
Zones 1-4 are Fast Loop Response . . . . . Section [030]: [1-4]                LINKS1000 and then the land line when an event occurs. To
                                                                               program this option, select both the telephone number and
                                                                               the LINKS options for the Communicator Call Direction
5.25 Keypad Tampers                                                            Options for the event. The Call LINKS as well as Land Line
If the Keypad Tampers Enable option is selected, the panel                     option must be selected.
will display and transmit a General System Tamper reporting
                                                                               LINKS Special Preamble
code if any keypad is removed from the wall. When the key-
                                                                               In some areas of North America, dialing #DAT or *DATA
pad tamper is restored, the panel will transmit the General
                                                                               reduces the cellular billing increment. The LINKS Special
System Tamper Restoral reporting code. All keypads should
                                                                               Preamble (section [393]), allows the use of [*] and [#] charac-
be properly installed and secured before enabling this option.
                                                                               ters for the programming of #DAT and *DATA.
NOTE:The auto arm cancellation code is not transmitted when
                                                                               The LINKS Special Preamble is sent BEFORE the Preamble
a reset is required because a user has not cancelled the auto-
                                                                               programmed in Sections [390] to [392].
arming sequence.
                                                                               Example: [Special Preamble][Regular Preamble][Telephone
                                                                               Number]
Keypad Tamper Enable . . . . . . . . . . . . . . . Section [016]: [8]
General System Tamper and Tamper                                               NOTE: If this Special Preamble is programmed, it will be
Restoral Reporting Codes . . . . . . . . . . . . . . . . Section [338]         inserted before the Regular Preamble of ALL telephone num-
                                                                               bers. Hex digits D and E are not supported for Preamble pro-
NOTE: After enabling keypad tampers, it is recommended to                      gramming.
tamper and restore all keypads to ensure proper functioning.                   NOTE: If Busy Tone Detection is enabled, the LINKS1000
                                                                               must be tested to ensure full operation.
5.26 LINKS1000 Cellular Communicator*
The LINKS1000 Cellular Communicator can be used three dif-                     Please refer to the LINKS1000 installation Manual for more
ferent ways:                                                                   information and connection diagrams.
• as the sole communicator for the panel
                                                                               LINKS Preamble (First Telephone Number). . . . Section [390]
• as a backup for either or both telephone numbers                             LINKS Preamble (Second Telephone Number) . Section [391]
• as a redundant backup to the land line communicator,                         LINKS Preamble (Third Telephone Number) . . . Section [392]
    where the panel will call using the land line and the LINKS.               LINKS Preamble
A LINKS Preamble is programmable for each telephone num-                       (Downloading Telephone Number) . . . . . . . . . . Section [490]
ber in the event that the land line number is local but the                    Communicator Call Direction Options . . . Section [361]-[368]
LINKS is required to dial an exchange. When programming a                      Call LINKS as well as Land Line . . . . . . . . .Section [380]: [7]
LINKS Preamble, all unused digits must be programmed with                      LINKS Special Preamble . . . . . . . . . . . . . . . . . . Section [393]
a hexadecimal “F”.
                                                                               *Not investigated by UL
                                                                                                                                                     25
5.27 Additional System Modules*                                                  5.29 Installer’s Lockout
The following modules are programmed through the module                          If Installer’s Lockout is selected, a hardware default cannot
programming sections [801]-[804]: the PC5400 Printer mod-                        be performed. If a software default is performed, all program-
ule, the Links2X50 Long-Range Radio module, the Skyroute                         ming will restore to factory default.
transceiver module, and the PC5132 Wireless Receiver and                         If Installer’s Lockout Disable is selected, the panel will
all of its devices. For instructions on the installation and pro-                restore all programming to factory defaults when a hardware
gramming of these additional modules and devices, please                         or software default is performed on the main control panel.
see their respective installation and programming manuals.                       To enable or disable Installer’s Lockout, perform the following:
                                                                                 1. Enter the Installer’s Programming mode.
PC5400 Printer Module Programming. . . . . . . . Section [801]
                                                                                 2. Enter the appropriate programming section: [990] or [991].
Alternative Comm. (LINKS2X50, Skyroute)
                                                                                 3. Enter the Installer’s Code.
Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . Section [803]
                                                                                 4. Re-enter the appropriate programming section: [990] or
PC5132 Programming . . . . . . . . . . . . . . . . . . . . Section [804]
                                                                                     [991].
Customer: _______________________________________________________________________________________________________
Address: ________________________________________________________________________________________________________
Zone 2 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 3 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 4 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 5 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 6 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 7 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 8 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 9 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 10 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 11 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 12 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 13 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 14 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 15 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 16 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 17 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 18 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 19 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 20 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 21 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 22 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 23 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 24 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 25 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 26 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 27 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 28 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 29 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 30 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 31 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
Zone 32 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I I_____I_____I_____I_____I_____I_____I
*Zone Attributes:
Option 1: Audible/Silent  Option 5: Force**
Option 2: Steady/Pulsed   Option 6: Swinger Shutdown
Option 3: Chime           Option 7: Transmission Delay
Option 4: Bypass          Option 8: Wireless
**NOTE: Option 5, Force Arming is not recommended for UL installations.
28
                                                                                                                  P r o g r a m m i n g     W o r k s h e e t s
Keypad Programming
[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
  00 Null Key                                 08 [*][1] Bypass Mode                                               16   [*][0] Quick Exit
  01 For future use                           09 [*][2] Trouble Display                                           17   [*][1] Reactivate Stay/Away’s
  02 For future use                           10 [*][3] Alarm Memory                                              18   For future use
  03 Stay Arm                                 11 [*][5] User Programming                                          19   For future use
  04 Away Arm                                 12 [*][6] User Functions                                            20   For future use
  05 [*][9] No-Entry Arm                      13 Command Output #1 [*][7][1]                                      21   For future use
  06 [*][4] Chime On / Off                    14 Command Output #2 [*][7][2]
  07 [*][6][——][4] System Test                15 For future use
                                  Slot            Function                     Function            Function               Function          Function
                                                   Key 1                        Key 2               Key 3                  Key 4             Key 5
LED Defaults                      11                 03                           04                  06                     14                16
LCD Defaults                      18                  03                                04             06                     14                16
KEYPAD 1                    I________I________I     I________I                        I________I     I________I             I________I        I________I
Basic Programming
Zone Definitions
 00 Null Zone (Not Used)                                   10    24 Hour Supervisory Buzzer                       20   24 Hour Freeze
 01 Delay 1                                                11    24 Hour Burglary                                 21   24 Hour Latching Tamper
 02 Delay 2                                                12    24 Hour Holdup                                   22   Momentary Keyswitch Arm
 03 Instant                                                13    24 Hour Gas                                      23   Maintained Keyswitch Arm
 04 Interior                                               14    24 Hour Heating (N/C zone)                       24   LINKS Answer
 05 Interior, Stay/Away                                    15    24 Hour Medical                                  25   Interior Delay
 06 Delay, Stay/Away                                       16    24 Hour Panic                                    87   Delay 24 Hour Fire (Wireless)
 07 Delayed 24 Hour Fire (Hardwired)                       17    24 Hour Emergency                                88   Standard 24 Hour Fire (Wireless)
 08 Standard 24 Hour Fire (Hardwired)                      18    24 Hour Sprinkler
 09 24 Hour Supervisory                                    19    24 Hour Water
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions (Section 5.2 “Zone Programming” on page 15)
  Default                          Default
    01    I_______I_______I Zone 1   00      I_______I_______I Zone 5
     03       I_______I_______I    Zone 2             00          I_______I_______I     Zone 6
     04       I_______I_______I    Zone 3             00          I_______I_______I     Zone 7
     04       I_______I_______I    Zone 4             00          I_______I_______I     Zone 8
                                                                                                                                                            29
NOTE:Zones 9-32 are only available for wireless zones.
[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming” on page 15)
  Default                          Default
    00    I_______I_______I Zone 9   00     I_______I_______I Zone 13
      00     I_______I_______I    Zone 10            00        I_______I_______I    Zone 14
      00     I_______I_______I    Zone 11            00        I_______I_______I    Zone 15
      00     I_______I_______I    Zone 12            00        I_______I_______I    Zone 16
[003] Zone 17-24 Definitions (Section 5.2 “Zone Programming” on page 15)
  Default                           Default
    00    I_______I_______I Zone 17   00    I_______I_______I Zone 21
      00     I_______I_______I    Zone 18            00        I_______I_______I    Zone 22
      00     I_______I_______I    Zone 19            00        I_______I_______I    Zone 23
      00     I_______I_______I    Zone 20            00        I_______I_______I    Zone 24
[004] Zone 25-32 Definitions (Section 5.2 “Zone Programming” on page 15)
  Default                           Default
    00    I_______I_______I Zone 25   00    I_______I_______I Zone 29
      00     I_______I_______I    Zone 26            00        I_______I_______I    Zone 30
      00     I_______I_______I    Zone 27            00        I_______I_______I    Zone 31
      00     I_______I_______I    Zone28             00        I_______I_______I    Zone 32
[005] System Times
 Default   Valid entries: [001-255]
   030    I_______I_______I_______I Entry Delay 1 (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
     045     I_______I_______I_______I      Entry Delay 2 (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
     120     I_______I_______I_______I      Exit Delay (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
     004     I_______I_______I_______I      Bell Cut-off (in minutes)(Section 5.13 “Bell” on page 22)
[006] Installer’s Code (Section 4.1 “Installer’s Programming” on page 13)
 Default
  5555     I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes” on page 15)
 Default
  1234    I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes” on page 15)
 Default
  AAAA    I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options” on page 20)
Programmable Output Options
    01 Burglary and Fire Bell Output                               14 Ground Start Pulse
    02 For future use                                              15 Remote Operation (DLS-1 Support)
    03 Sensor Reset                                                16 LINKS1000 Support (PGM1 only)
    04 For future use                                              17 Away Armed Status
    05 System Armed Status                                         18 Stay Armed Status
    06 Ready To Arm                                                19 Command Output #1 ([*][7][1])
    07 Keypad Buzzer Follow Mode                                   20 Command Output #2 ([*][7][2])
    08 Courtesy Pulse                                              21 For future use
    09 System Trouble Output (with Trouble options)                22 For future use
    10 System Event [Strobe (with Event options)]                  23 For future use
    11 System Tamper (all sources: zones, kpd, modules)            24 For future use
    12 TLM and Alarm
    13 Kissoff Output
NOTE:Output types [03] and [20] cannot be used together on the same system.
 Default                                              Default
     19     I_______I_______I     PGM 1                   10          I_______I_______I   PGM 2   Program PGM Option Attributes in sections [141] & [142].
30
                                                                                                        P r o g r a m m i n g   W o r k s h e e t s
[012] Keypad Lockout Options (Section 5.21 “Keypad Lockout Options” on page 24)
NOTE:If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
 Default
  000          I_______I_______I_______I   Number of Invalid Codes Before Lockout (001-255 codes)
   000         I_______I_______I_______I   Lockout Duration (001-255 minutes)
[013] First System Option Code
 Default         Option ON                                                          Off                                            Section Page #
  OFF I________I   1    Normally Closed Loops                                       End-of-Line Resistors                            2.8     5
  OFF      I________I          2             Double End-of-Line Resistors           Single End-of-Line Resistors                     2.8      5
  ON*      I________I          3             Panel shows all troubles when armed    Panel shows only Fire troubles when armed        3.4      8
  OFF      I________I          4             Tampers/Faults do not show as open     Tampers/Faults show as open                      3.4      8
  OFF      I________I          5             For future use
   ON      I________I          6             Audible Exit Fault Enabled             Audible Exit Fault Disabled                      5.18     24
   ON      I________I          7             Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown            5.20     24
  OFF      I________I          8             Temporal Three Fire Signal Enabled**   Standard Pulsed Fire Signal                      5.13     22
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
**The Temporal Three Fire Signal option must be used for UL Household Fire installations.
[014] Second System Option Code
 Default         Option ON                                                          Off                                            Section Page #
  OFF I________I   1    Arm / Disarm Bell Squawk enabled                            Arm / Disarm Bell Squawk disabled               5.17     23
  OFF      I________I          2             Bell Squawk During Auto Arm            No Bell Squawk During Auto Arm                  5.18      24
  OFF      I________I          3             Bell Squawk On Exit Delay              No Bell Squawk On Exit Delay                    5.18      24
  OFF      I________I          4             Bell Squawk On Entry Delay             No Bell Squawk On Entry Delay                   5.18      24
  OFF      I________I          5             Bell Squawk On Trouble                 No Bell Squawk On Trouble                        3.4      8
   ON      I________I          6             Audible Exit with Urgency              Silent Exit Delay                               5.18      24
  OFF      I________I          7             Exit Delay Termination Enabled         Exit Delay Termination Disabled                 5.18      24
  OFF      I________I          8             Fire Bell is Continuous                Fire Bell Follows Bell Cut-off                  5.13      22
[015] Third System Option Code
 Default         Option ON                                                          Off                                            Section Page #
   ON I________I   1    Fire Keys Enabled                                           Fire Keys Disabled                              5.16     23
  OFF      I________I          2             Panic Keys Audible (Bell / Beeps)      Panic Keys Silent                                5.16    23
  OFF      I________I          3             Quick Exit Enabled                     Quick Exit Disabled                              3.4      8
  ON*      I________I          4             Quick Arming Enabled                   Quick Arming Dis. / Function keys Req. Code      3.4      8
  OFF      I________I          5             Code Required For Bypassing            No Code Required                                 3.4      8
  OFF      I________I          6             Master Code Not Changeable             Master Code Changeable                           5.1     15
   ON      I________I          7             TLM Enabled                            TLM Disabled                                     5.12    22
  OFF      I________I          8             TLM Audible (Bell) When Armed          TLM Trouble Beeps When Armed                     5.12    22
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
 Default         Option ON                                                          Off                                            Section Page #
   ON I________I   1    AC Trouble Displayed                                        AC Trouble Not Displayed                         3.4     8
  OFF      I________I          2             Trouble Light Flashes if AC Fails      Trouble Light Does Not Follow AC Status          3.4      8
  OFF      I________I          3             Blank Keypad When Not Used             Keypad Active Always                             5.22     24
  OFF      I________I          4             Code Required to Remove Kypd BlankingNo Code Required                                   5.22     24
   ON      I________I          5             Keypad Backlighting is enabled         Keypad Backlighting is disabled                  5.23     25
  OFF      I________I          6             Power Save Mode enabled                Power Save Mode disabled                         5.22     24
  OFF      I________I          7             Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed             5.17     23
  OFF      I________I          8             Keypad Tampers enabled                 Keypad Tampers disabled                          5.25     25
                                                                                                                                                   31
[017] Fifth System Option Code
 Default        Option ON                                                      Off                                 Section Page #
  ON I________I   1    WLS Key Does Not Use Access Codes*                      WLS Key Uses Access Codes            5.17     23
     OFF   I________I        2-7         For future use
     OFF   I________I          8         Squawk on Away Arming/Disarming OnlyBell Squawk on all Arming/Disarming    5.17    23
*This option must be enabled when using a PC5132 v2.1 or earlier.
32
                                                                                          P r o g r a m m i n g           W o r k s h e e t s
                                                                                                                                                33
[115]            15       (         )               I________I             I________|          I________|              I________|              I________|          I________|            I________|          I________I
PGM Output Attributes (Section 5.11 “PGM Output Options” on page 20)
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
 Attribute:                                    1                    2                   3                      4                       5
                           ON           Output enabled              —           True Output          Follows Timer              Code Req.
 Attribute:                                   1                    2                    3                      4                       5                       6                     7                      8
 PGM Option
                              ON          Serv. req.             AC Fail          TLM Fault                   FTC               Zone Fault                  Zone Tmp.           Zn. Low Bat.          Loss of Clock
                              OFF         Disabled          Disabled               Disabled                 Disabled                Disabled                Disabled             Disabled                Disabled
 [09] System Trouble                          Y                    Y                    Y                      Y                       Y                       Y                     Y                      Y
                              ON         Burg. Evnt.        Fire Evnt.           Panic Evnt.           Med. Evnt.               Supv. Evnt.            Priority Evnt.           Holdup Evnt.          Follows Timer*
                              OFF         Disabled          Disabled               Disabled                 Disabled                Disabled                Disabled             Disabled                Latched
 [10] System Event                            Y                    Y                    Y                      Y                       Y                       Y                     Y                      N
                                        *If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
34
                                                                                                                                                                                     P r o g r a m m i n g                               W o r k s h e e t s
[160] Maximum Dialing Attempts to Each Telephone Number (Section 5.5 “Communicator – Dialing” on page 17)
Default: 008 I_______I_______I_______I Valid entries are 001-015 attempts (do not enter 000).
[161] Post Dial Wait for Handshake (All Formats) (Section 5.5 “Communicator – Dialing” on page 17)
Default: 040 I_______I_______I_______I Valid entries are 001-255 seconds
[164] PGM Output Timer (Section 5.5 “Communicator – Dialing” on page 17)
Default: 005 I_______I_______I_______I Valid entries are 001-255 seconds
[202] Zone Assignments 01-08 (Section 5.2 “Zone Programming” on page 15)
Program zone definitions in sections [001] - [004] and zone attributes in sections [101] - [132]. Program keypad zone assignments
in section [020].
NOTE:Any zones not used on the system should be disabled in this section. Disabled wireless zones should have a blank serial
number (i.e. [000000]).
Zones 1-8: Default = ON; Zones 9-32: Default = OFF
 Section Option:       1            2            3                                                                                      4                            5                             6                          7                             8
  [202]              Zone 1      Zone 2        Zone 3                                                                                 Zone 4                       Zone 5                        Zone 6                     Zone 7                        Zone 8
                                               I______________I               I______________I           I______________I             I______________I            I______________I             I______________I             I______________I              I______________I
Communicator Programming
NOTE: For sections [301] to [353], the content of every section by default is [F].
[301] First Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[302] Second Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[303] Third Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[310] First/Third Telephone Number Account Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
[311] Second Telephone Number Account Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
Alarm Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
  [320] Zone 1      Zone 2       Zone 3           Zone 4          Zone 5          Zone 6          Zone 7                                                                                                                                                           Zone 8
                        I_______I_______I                 I_______I_______I                 I_______I_______I                I_______I_______I                 I_______I_______I                 I_______I_______I                I_______I_______I                I_______I_______I
                                                                                                                                                                                                                                                                               35
Alarm Restoral Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
  [324] Zone 1       Zone 2      Zone 3        Zone 4         Zone 5            Zone 6          Zone 7          Zone 8
                  I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I     I_______I_______I   I_______I_______I   I_______I_______I   I_______I_______I
[328] Miscellaneous Alarm Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
      I_______I_______I 1. Duress Alarm   I_______I_______I 4. Zone Expander Supervisory Alarm
         I_______I_______I   2. Opening After Alarm                            I_______I_______I     5. Zone Expander Supervisory Restoral
         I_______I_______I   3. Recent Closing                                 I_______I_______I     6. Cross Zone Police Code Alarm
[329] Priority Alarm and Restoral (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
      I_______I_______I 1. Keypad Fire Alarm     I_______I_______I 5. Keypad Fire Restoral
         I_______I_______I   2. Keypad Auxiliary Alarm                         I_______I_______I     6. Keypad Auxiliary Restoral
         I_______I_______I   3. Keypad Panic Alarm                             I_______I_______I     7. Keypad Panic Restoral
         I_______I_______I   4. For future use                                 I_______I_______I     8. For future use
Tamper Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
 Section
  [330]  Zone 1     Zone 2      Zone 3            Zone 4         Zone 5          Zone 6           Zone 7                                                                  Zone 8
                  I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I     I_______I_______I   I_______I_______I   I_______I_______I   I_______I_______I
Tamper Restoral Reporting Codes, Zones 1-8 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
 Section
  [334]  Zone 1     Zone 2       Zone 3       Zone 4          Zone 5            Zone 6          Zone 7          Zone 8
                  I_______I_______I    I_______I_______I   I_______I_______I            I_______I_______I     I_______I_______I   I_______I_______I   I_______I_______I   I_______I_______I
[338] Miscellaneous Tamper Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
      I_______I_______I 1. General System Tamper
36
                                                                                                                                           P r o g r a m m i n g           W o r k s h e e t s
Closing (Arming) Reporting Codes, Access Codes 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
 Section
  [339]   Code 1       Code 2       Code 3      Code 4           Code 5          Code 6          Code 7          Code 8
                 I_______I_______I     I_______I_______I   I_______I_______I           I_______I_______I               I_______I_______I        I_______I_______I   I_______I_______I   I_______I_______I
*The LINKS Test Transmission Code must be programmed as “00” for the LINKS Test Transmission to be disabled.
                                                                                                                                                                                                     37
[353] Wireless Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
      I_______I_______I 1. Wireless Device Low Battery Alarm I_______I_______I 2. Wireless Device Low Battery Restore
[360] Communicator Format Options (Section 5.9 “Communicator – Reporting Formats” on page 19)
NOTE:The Third telephone number follows the format of the First telephone number.
 Default
   02      I_______I_______I        1st/3rd Telephone Number
     02    I_______I_______I        2nd Telephone Number
     01 20 BPS, 1400 HZ handshake                    04 SIA FSK
     02 20 BPS, 2300 HZ handshake                    05 Pager
     03 DTMF CONTACT ID
[361] Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default            Option ON                                      OFF
   ON     I_______I   1    1st Telephone Number                    Disabled
     OFF   I_______I           2           2nd Telephone Number               Disabled
     OFF   I_______I           3           1st Telephone Number (via LINKS)   Disabled
     OFF   I_______I           4           2nd Telephone Number (via LINKS)   Disabled
     OFF   I_______I           5-8         For future use
[363] Tamper/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default            Option ON                                      OFF
   ON    I________I   1    1st Telephone Number                    Disabled
     OFF   I________I           2          2nd Telephone Number               Disabled
     OFF   I________I           3          1st Telephone Number (via LINKS)   Disabled
     OFF   I________I           4          2nd Telephone Number (via LINKS)   Disabled
     OFF   I________I          5-8         For future use
[365] Opening/Closing Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default            Option ON                                      OFF
   ON    I________I   1    1st Telephone Number                    Disabled
     OFF   I________I           2          2nd Telephone Number               Disabled
     OFF   I________I           3          1st Telephone Number (via LINKS)   Disabled
     OFF   I________I           4          2nd Telephone Number (via LINKS)   Disabled
     OFF   I________I          5-8         For future use
[367] System Maintenance Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default             Option ON                                   OFF
   ON     I________I   1    1st Telephone Number                 Disabled
     OFF   I________I           2          2nd Telephone Number               Disabled
     OFF   I________I           3          1st Telephone Number (via LINKS)   Disabled
     OFF   I________I           4          2nd Telephone Number (via LINKS)   Disabled
     OFF   I________I          5-8         For future use
[368] System Test Transmissions Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
 Default            Option ON                                  OFF
   ON    I________I   1    1st Telephone Number                Disabled
     OFF   I________I           2          2nd Telephone Number               Disabled
     OFF   I________I           3          1st Telephone Number (via LINKS)   Disabled
     OFF   I________I           4          2nd Telephone Number (via LINKS)   Disabled
  OFF    I________I 5-8  For future use
NOTE:The LINKS1000 backup call directions will only back up their respective telephone numbers.
38
                                                                                                                            P r o g r a m m i n g    W o r k s h e e t s
                                                                                                                                                                        39
Downloading Options
[401] First Downloading Option Code (Section 5.10 “Downloading” on page 20)
 Default        Option ON                                   Off
  OFF I_______I   1    Answering machine/double call enabledAnswering machine/double call disabled
      ON            I_______I             2               User Can Enable DLS Window                                                             User Cannot Enable DLS Window
     OFF            I_______I             3               Call-Back Enabled                                                                      Call-Back Disabled
     OFF            I_______I             4               User-initiated call-up enabled                                                         User-initiated call-up disabled
     OFF            I_______I           5-8               For future use
[402] Downloading Computer’s Telephone Number (32 Digits) (Section 5.10 “Downloading” on page 20)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
International Programming
[701] First International Options Code
 Default        Option ON                                                                                                                              Off                                          Section Page #
  OFF I_______I   1-4  For Future Use
     OFF            I_______I             5               6-Digit User Access Codes                                                                    4-Digit User Access Codes                      5.1    15
     OFF            I_______I             6               Busy tone detection enabled                                                                  Busy tone detection disabled                   5.5    17
      OFF           I_______I           7-8               For Future Use
Module Programming*
[801] PC5400 Printer Module Programming
Please refer to your PC5400 Installation Manual for installation and programming instructions.
[803] Alternative Communicator Programming
Please refer to your LINKS2X50, Skyroute Installation Manual for installation and programming instructions.
[804] PC5132 Wireless Expansion Programming
Please refer to your PC5132 Installation Manual for programming locations and instructions.
* LINKS2X50 and Skyroute modules have not been investigated by UL.
40
                                                                                    P r o g r a m m i n g   W o r k s h e e t s
[996] Restore PC5132 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
[997] Restore PC5400 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
[999] Restore PC580 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
                                                                                                                            41
                 A p p e n d ix A: R e p o rti ng Co d e s
The following tables contain Contact ID and Automatic SIA for-            SIA Format - Level 2 (Hardcoded)
mat reporting codes. For more information on reporting code               The SIA communication format used in this product follows the
formats and notes about individual reporting codes, see sec-              level 2 specifications of the SIA Digital Communication Stan-
tions 5.8 “Communicator – Reporting Codes” on page 18 and                 dard - January 1996. This format will send the Account Code
5.9 “Communicator – Reporting Formats” on page 19.                        along with its data transmission. The transmission would look
Contact ID                                                                similar to the following at the receiver:
The first digit (in parentheses) will automatically be sent by the                          N Ri01           BA 01
control. The second two digits are programmed to indicate spe-                                    N     =    New Event
cific information about the signal.                                                            Ri01     =    Partition /Area Identifier
For example, if zone 1 is an entry/exit point, you could program                                BA      =    Burglary Alarm
the event code as [34]. The central station would receive the                                    01     =    Zone 1
following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
42
                                                                                                                                       R e p o r t i n g         C o d e s
   Table2: Contact ID Zone Alarm/Restoral Event                                                      Table 3: SIA Format Automatic Zone
   Codes (as per ADEMCO):                                                                            Alarm/Restoral Codes
   Program any of these codes for zone alarms/restorals when using
   the standard (non-automatic) Contact ID reporting format.                                                                                     SIA Auto Rep
                                                                                                      Zone Definition                               Codes*
   Medical Alarms                           (1)34 Entry / Exit
   (1)AA Medical                            (1)35 Day / Night                                                                                   Zone Alm/Rest.
   (1)A1 Pendant Transmitter                (1)36 Outdoor                                             Delay, Instant, Interior, Delay            BA-ZZ/BH-ZZ
   (1)A2 Fail to Report In                  (1)37 Tamper                                              Stay/Away, Interior Stay/Away,
   Fire Alarms                              (1)38 Near Alarm                                          24Hr Burg.
   (1)1A Fire Alarm                         General Alarms                                            Standard 24Hr Fire, Delayed                FA-ZZ/FH-ZZ
   (1)11 Smoke                              (1)4A General Alarm                                       24Hr Fire
   (1)12 Combustion                         (1)43 Exp. module failure                                 24Hr Supervisory                           US-ZZ/UR-ZZ
   (1)13 Water Flow                         (1)44 Sensor tamper
   (1)14 Heat                               (1)45 Module Tamper                                       24Hr Supervisory Buzzer                    UA-ZZ/UH-ZZ
   (1)15 Pull Station                       (1)4A Cross Zone Police Code                              24Hr Sprinkler                             SA-ZZ/SH-ZZ
   (1)16 Duct                               24 Hour Non-Burglary                                      24Hr Gas                                   GA-ZZ/GH-ZZ
   (1)17 Flame                              (1)5A 24 Hour non-Burg
                                                                                                      24Hr Heat                                  KA-ZZ/KH-ZZ
   (1)18 Near Alarm                         (1)51 Gas detected
   Panic Alarms                             (1)52 Refrigeration                                       24Hr Medical                              MA-ZZ/MH-ZZ
   (1)2A Panic                              (1)53 Loss of Heat                                        24Hr Emergency (non-medical)               QA-ZZ/QH-ZZ
   (1)21 Duress                             (1)54 Water Leakage
                                                                                                      24Hr Waterflow                            WA-ZZ/WH-ZZ
   (1)22 Silent                             (1)55 Foil Break
   (1)23 Audible                            (1)56 Day Trouble                                         24Hr Freeze                                ZA-ZZ/ZH-ZZ
   Burglar Alarms                           (1)57 Low bottled Gas level                               24Hr Holdup                                HA-ZZ/HH-ZZ
   (1)3A Burglary                           (1)58 High Temp                                           24Hr Panic                                 PA-ZZ/PH-ZZ
   (1)31 Perimeter                          (1)59 Low Temp
   (1)32 Interior                           (1)61 Loss of Air Flow                                    Latching 24Hr                              BA-ZZ/BH-ZZ
   (1)33 24 Hour                                                                                                                            * ZZ = zones 01-08
                                                                                                                                                                           43
      Appendix B: Programming LCD Keypads
If you have an LCD5500Z Keypad, additional programming is required for proper operation. The following is a description of the
available programming options and their accompanying programming sections:
How to Enter LCD Programming
Follow the programming procedure as outlined in Section 4 by pressing [*][8][Installer’s Code]. Press the [*] key. Enter the two
digit Section number to be programmed.
Programmable Labels – Sections [01] - [08], [33], [34], [40], [44], [51], [52]
Zone labels and other LCD display identifiers can be customized to make operation of the system easier for the end user. The fol-
lowing procedure should be used for creating all LCD labels:
• Enter Installer’s Programming. Enter the Number corresponding to the label to be programmed.
• Use the arrow keys (<>) to move the underline bar underneath the letter to be changed.
• Press the number key [1] to [9] corresponding to the letter you require. The first time you press the number the first letter will
  appear. Pressing the number key again will display the next letter. Refer to the following chart:
   [1] - A, B, C, 1    [2] - D, E, F, 2 [3] - G, H, I, 3 [4] - J, K, L, 4     [5] - M, N, O, 5
   [6] - P, Q, R, 6    [7] - S, T, U, 7 [8] - V, W, X, 8 [9] - Y, Z, 9,0     [0] - Space
• When the required letter or number is displayed use the arrow keys (<>) to scroll to the next letter.
• When you are finished programming the Zone Label, press the [*] key, scroll to “Save,” then press [*].
• Continue from Step 2 until all Labels are programmed.
[01] to [32] Zone Labels (14 Characters)
     Default: “Zone 1” - “Zone 32”
       Record zone labels on page 28
[33] Fire Alarm Label (14 Characters)
     Default: “Fire Zone”     I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
44
                                                                                            P r o g r a m m i n g       L C D    K e y p a d s
                                                                                                                                              45
UL Listed Commercial and Residential Installations
The installation requirements listed below must be met for the follow-   Control of the Protected Premises
ing grades of service.                                                   In order to have a UL Certificated system the protected area is to be
Grade A Local                                                            under the responsibility of one ownership and management (i.e. one
The installation must have a bell UL Listed for mecantile local alarms   business under one name). This may be a group of buildings
(AMSECO MBL10B with model AB-12 bell housing).                           attached or unattached with different addresses but under the
The digital communicator must be enabled.                                responsibility of someone having mutual interest. The person of
The control panel must be in the Attack Resistant Enclosure (DSC         mutual interest is not the alarm installing company.
Model CMC-1).                                                            Bell Location
Swinger shutdown must be disabled.                                       The alarm sounding device (bell) must be located where it can be
Grade B Central Station and Police Connect                               heard by the person or persons responsible for maintaining the secu-
The installation must have a bell UL Listed for mecantile local alarms   rity system during the daily arming cycle.
(AMSECO MBL10B with model AB-12 bell housing).                           Protection of the Control Unit
The digital communicator must be enabled.                                The local control and the local power supply must be protected by
Ringback must be enabled.                                                one of the following ways:
The control panel must be in the Attack Resistant Enclosure (DSC         • The control unit and audible alarm device power supply must be
Model CMC-1).                                                                 in a protected area which is armed 24 hours a day.
Swinger shutdown must be disabled.                                       • Each partition shall arm the area protecting the control unit and
Grade C Central Station                                                       the audible alarm device power supply. This may require dupli-
The digital communicator must be enabled.                                     cate protection armed by each partition. Access to this protected
Ringback must be enabled.                                                     area, without causing an alarm, will require that all partitions be
The control panel must be in the Attack Resistant Enclosure (DSC              disarmed.
Model CMC-1).                                                            In all cases described above, the protected area for the control unit
Swinger shutdown must be disabled.                                       must be programmed as not bypassable.
All Commercial Installations                                             Casual Users
• The entry delay must not exceed 60 seconds                             The installer should caution the user(s) to not give system information
• The exit delay must not exceed 60 seconds.                             to casual users (e.g. codes, bypass methods, etc. to baby-sitters or
• The minimum bell cutoff time is 15 minutes.                            service people). Only the One-Time Use codes should be given to
                                                                         casual users.
Residential Installations
• The entry delay must not exceed 45 seconds                             User Information
• The exit delay must not exceed 60 seconds.                             The installer should advise the users and note in the user instruction
• The minimum bell cutoff time is 4 minutes.                             manual:
                                                                         • Service organization name and telephone number
Programming                                                              • The programmed exit time
The notes in the programming sections describing the system config-      • The programmed entry time
urations for UL Listed installations must be implemented.
46
F CC C O M P L IA N C E S TAT E M E N T
CAUTION: Changes or modifications not expressly approved by Digital               equivalent, in such a manner as to allow for easy, immediate disconnection of
Security Controls Ltd. could void your authority to use this equipment.           the terminal equipment. Standard jacks shall be so arranged that, if the plug
This equipment has been tested and found to comply with the limits for a          connected thereto is withdrawn, no interference to the operation of the equip-
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are    ment at the customer’s premises which remains connected to the telephone
designed to provide reasonable protection against harmful interference in a       network shall occur by reason of such withdrawal.
residential installation. This equipment generates, uses and can radiate radio    INCIDENCE OF HARM Should terminal equipment or protective circuitry
frequency energy and, if not installed and used in accordance with the            cause harm to the telephone network, the telephone company shall, where
instructions, may cause harmful interference to radio communications. How-        practicable, notify the customer that temporary disconnection of service may
ever, there is no guarantee that interference will not occur in a particular      be required; however, where prior notice is not practicable, the telephone
installation. If this equipment does cause harmful interference to radio or       company may temporarily discontinue service if such action is deemed rea-
television reception, which can be determined by turning the equipment off        sonable in the circumstances. In the case of such temporary discontinuance,
and on, the user is encouraged to try to correct the interference by one or       the telephone company shall promptly notify the customer and will be given
more of the following measures:                                                   the opportunity to correct the situation.
•   Re-orient the receiving antenna.                                              ADDITIONAL TELEPHONE COMPANY INFORMATION The security control
•   Increase the separation between the equipment and receiver.                   panel must be properly connected to the telephone line with a USOC RJ-31X
•   Connect the equipment into an outlet on a circuit different from that         telephone jack.
    to which the receiver is connected.                                           The FCC prohibits customer-provided terminal equipment be connected to
                                                                                  party lines or to be used in conjunction with coin telephone service. Intercon-
•   Consult the dealer or an experienced radio/television technician for
                                                                                  nect rules may vary from state to state.
    help.
                                                                                  CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The tele-
The user may find the following booklet prepared by the FCC useful: “How
                                                                                  phone company may make changes in its communications facilities, equip-
to Identify and Resolve Radio/Television Interference Problems”. This book-
                                                                                  ment, operations or procedures, where such actions are reasonably required
let is available from the U.S. Government Printing Office, Washington D.C.
                                                                                  and proper in its business. Should any such changes render the customer’s
20402, Stock # 004-000-00345-4.
                                                                                  terminal equipment incompatible with the telephone company facilities the
Im p o rta n t In for m a t i o n
This equipment complies with Part 68 of the FCC Rules. On the side of this        customer shall be given adequate notice to the effect modifications to main-
equipment is a label that contains, among other information, the FCC regis-       tain uninterrupted service.
tration number of this equipment.                                                 RINGER EQUIVALENCE NUMBER (REN) The REN is useful to determine the
NOTIFICATION TO TELEPHONE COMPANY The customer shall notify the tele-             quantity of devices that you may connect to your telephone line and still have
phone company of the particular line to which the connection will be made,        all of those devices ring when your telephone number is called. In most, but
and provide the FCC registration number and the ringer equivalence of the         not all areas, the sum of the RENs of all devices connected to one line should
protective circuit.                                                               not exceed five (5.0). To be certain of the number of devices that you may con-
                                                                                  nect to your line, you may want to contact your local telephone company.
FCC Registration Number: F53CAN-32394-AL-E                                        EQUIPMENT MAINTENANCE FACILITY If you experience trouble with this
Ringer Equivalence Number: 0.0B                                                   telephone equipment, please contact the facility indicated below for informa-
                                                                                  tion on obtaining service or repairs. The telephone company may ask that
USOC Jack: RJ-31X
                                                                                  you disconnect this equipment from the network until the problem has been
TELEPHONE CONNECTION REQUIREMENTS Except for the telephone com-                   corrected or until you are sure that the equipment is not malfunctioning.
pany provided ringers, all connections to the telephone network shall be          Digital Security Controls Ltd. 160 Washburn St., Lockport, NY 14094
made through standard plugs and telephone company provided jacks, or
AVIS: L’étiquette de l’Industrie Canada identifie le matériel homologué.          NOTICE: The Industry Canada label identifies certified equipment. This
Cette étiquette certifie que le matériel est conforme à certaines normes          certification means that the equipment meets certain telecommunica-
de protection, d’exploitation et de sécurité des réseaux de télécommuni-          tions network protective, operational and safety requirements. Industry
cations. Industrie Canada n’assure toutefois pas que le matériel fonc-            Canada does not guarantee the equipment will operate to the user’s sat-
tionnera à la satisfaction de l’utilisateur.                                      isfaction.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de   Before installing this equipment, users should ensure that it is permissi-
le raccorder aux installations de l’entreprise locale de télécommunica-           ble to be connected to the facilities of the local telecommunications
tion. Le matériel doit également être installé en suivant une méthode             company. The equipment must also be installed using an acceptable
acceptée de raccordement. L’abonné ne doit pas oublier qu’il est possi-           method of connection. The customer should be aware that compliance
ble que la conformité aux conditions énoncées ci-dessus n’empêchent               with the above conditions may not prevent degradation of service in
pas la dégradation du service dans certaines situations.                          some situations.
Les réparations de matériel homologué doivent être effectuées par un              Repairs to certified equipment should be made by an authorized Cana-
centre d’entretien canadien autorisé désigné par le fournisseur. La               dian maintenance facility designated by the supplier. Any repairs or
compagnie de télécommunications peut demander à l’utilisateur de                  alterations made by the user to this equipment, or equipment malfunc-
débrancher un appareil à la suite de réparations ou de modifications              tions, may give the telecommunications company cause to request the
effectuées par l’utilisateur ou à cause de mauvais fonctionnement.                user to disconnect the equipment.
Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de      User should ensure for their own protection that the electrical ground
mise à la terre de la source d’énergie électrique, les lignes télépho-            connections of the power utility, telephone lines and internal metallic
niques et les canalisations d’eau métalliques, s’il y en a, sont raccordés        water pipe system, if present, are connected together. This precaution
ensemble. Cette précaution est particulièrement importante dans les               may be particularly important in rural areas.
régions rurales.                                                                  CAUTION: Users should not attempt to make such connections them-
AVERTISSEMENT: L’utilisateur ne doit pas tenter de faire ces raccorde-            selves, but should contact the appropriate electric inspection authority,
ments lui-même; il doit avoir recours à un service d’inspection des instal-       or electrician, as appropriate.
lations électriques, ou à un électricien, selon le cas.                           The Load Number (LN) assigned to each terminal device denotes the
L’indice de charge (IC) assigné a chaque dispositif terminal indique,             percentage of the total load to be connected to a telephone loop which
pour éviter toute surcharge, le pourcentage de la charge totale qui peut          is used by the device, to prevent overloading. The termination on a loop
être raccordée à un circuit téléphonique bouclé utilisé par ce dispositif.        may consist of any combination of devices subject only to the require-
La terminaison du circuit bouclé peut être constituée de n’importe quelle         ment that the total of the Load Numbers of all the devices does not
combinaison de dispositifs, pourvu que la somme des indices de charge             exceed 100.
de l’ensemble des dispositifs ne dépasse pas 100.                                 The Load Number of this unit is 0.1B.
L’Indice de charge de ce produit est 0.1B.
                                           PC580 Module Compatibility
           Module                     Compatible?    Comments
           Classic Escort (VPM-1)          No
           Escort5580                      No
           PC-16 Out                       No
           PC5204                          No
           PC5208                          No
           PC5108                          No
           PC5108L                         No
           PC5132 v1.X                     Yes       No support for Wireless Keys, Pendants or Handheld Keypads
           PC5132 v2.X                     Yes       No identified Wireless Keys support
           PC5132 v3.X                     Yes
           PC5506                          No
           PC55XX                          Yes       No Keypad zone support
           PC55XXZ                         Yes
           LCD5500 v1.X                    Yes       No Keypad zone support; Some display messages not supported
           LCD5500Z v2.X                   Yes
           LCD600                          No
           LED615                          No
           SL-XX                           No
           PC1500RK                        No
           PC1555RKZ                       Yes
           PC5908                          No
           PC5928                          No
           PC5400 Printer                  Yes       Some printing messages not supported
           Module v1.X to v2.1
           PC5400 Printer                  Yes
           Module v2.2
           Links1000*                      Yes
           Links2150*                      Yes
           Links2450*                      Yes
           Skyroute*                       Yes