0% found this document useful (0 votes)
169 views1 page

Explosion Proof LED Ballast & Inverter

This document describes an explosion proof ballast and emergency inverter system for LED lighting in hazardous locations. It includes the HFX LED power supply and ARC 600/1200 LED lamps. The HFX LED supply provides constant current to the lamps and includes a battery charger/inverter for backup power. The ARC LED lamps are designed to replace fluorescent lamps and provide high light output, long lifespan, and high efficiency. The system is certified for use in hazardous gas zones and is suitable for applications like gas stations, fuel storage, mines, chemical plants, and offshore installations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views1 page

Explosion Proof LED Ballast & Inverter

This document describes an explosion proof ballast and emergency inverter system for LED lighting in hazardous locations. It includes the HFX LED power supply and ARC 600/1200 LED lamps. The HFX LED supply provides constant current to the lamps and includes a battery charger/inverter for backup power. The ARC LED lamps are designed to replace fluorescent lamps and provide high light output, long lifespan, and high efficiency. The system is certified for use in hazardous gas zones and is suitable for applications like gas stations, fuel storage, mines, chemical plants, and offshore installations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Explosion proof Ballast and Emergency

inverter for use with ARC lamps - LED version

D ESC RI PT I ON
The new Barel LED series is
designed to replace
fluorescent lamps in
conventional luminaries for
Ex zones 1 & 2. HFX LED is a
constant current power supply
designed to meet the special
requirements of LED operation TECHNICAL DATA
HFX/HFXE Certification: Presafe 14 ATEX 5355U, IECEx PRE 14.0039U
HFXE LED version includes a
Apparatus category/EPL: Ex II 2G / Gb
battery charger and inverter to
Type of protection: Ex eb mb IIC T4
operate the LED lamp from a
Amb. Temp.(Ta) / Tc: HFXE: (-52 to +65°C ) / 77°C – HFX: (-42 to +65°C) / 77°C
back-up battery
Rated voltage / Frequency: 110 – 254V AC/ 220-250VDC / 50/60Hz / DC
Power factor: 0,90 – 0,96
ARC 600 / ARC 1200 LED
Basic dimensions (LxWxH): HFXE: 285 x 75 x 32 mm – HFX: 285 x 41 x 32 mm
Lamps are designed to replace
Weight (for reference only): HFXE: 960g – HFX: 510g
traditional fluorescent lamps
- -
ARC LED certification: Presafe 15 ATEX 6296U, IECEx PRE 15.0014U
Apparatus category/EPL: Ex II 2G / Gb
Suit able f or us e in:
Superior functional life, Type of protection: Ex mb op is IIC T4
practical use and high Amb. Temp.(Ta) / Tc: ARC600: (-52 to +65°C ) / 80°C – ARC1200: (-52 to +65°C) / 80°C
efficiency are the key Light output Lumen: ARC600: 2500-2800 - ARC1200: 5000 - 5600 - Emergency: 25 %
benefits from choosing the
Battery pack: 4,8V 4Ah or 8,4V 4Ah / NiCd ogrNiMh cells
new Barel Ex LED system in
Expected system life time: >50000h at Ta 45°C
Gas Stations
Basic dimensions (LxWxH): ARC600: 576 x 61 x 11 mm – ARC1200: 1136 x 61 x 11 mm
Fuel Reservoirs
Weight (for reference only): ARC600: 630 g – ARC1200: 1250 g (for reference only)
Oil Tankers
Mines
Plants
Mills
On / Offshore installations

Chemical Industry
Marine