Explosion Protection Conform To 2014/34/EU: Ex Ia IIC T6 Ga
Explosion Protection Conform To 2014/34/EU: Ex Ia IIC T6 Ga
Zoning
     Classification of potentially explosion hazardous areas
     Duration–                                                            Continuous hazard                                            Occasional hazard                                                              Temporary hazard
     for information only:
                                                                          Zone 0              Zone 20             Zone 20              Zone 1                  Zone 21                    Zone 21                     Zone 2                  Zone 22             Zone 22
                              IEC                                         (gas)               (dust)              (lint)               (gas)                   (dust)                     (lint)                      (gas)                   (dust)              (lint)
                              CENELEC
                              Europe
                                                                          Ga                  Da                  Da                   Gb                      Db                         Db                          Gc                      Dc                  Dc
     Equipment protection level (EPL)
Class I Class II Class III Class I Class II Class III Class I Class II Class III
North America
                                                                                                                                                                                                                                                                                                                                   INFO
     Zone             Symbol                          Category                  Protection                         Zone         Symbol                 Category                    Protection                                        Categorie            Materials
                                                                                requirements                                                                                       requirements
     0                                                1 G required              2 independant means of             20                    
                                                                                                                                                       1 D required                2 independant means of                            IIIA                 flammable lints
                              
                                                                                protection                                                                                         protection
     1                                          2 G required,
                                                      1 G possible
                                                                                1 independant mean of
                                                                                protection
                                                                                                                   21                           2 D required,
                                                                                                                                                       1 D possible
                                                                                                                                                                                   1 independant mean of
                                                                                                                                                                                   protection
                                                                                                                                                                                                                                     IIIB                 non conductive dust
                                                                                                                                                                                                                                                                                                                                   Explosion protection
     2                                          3 G required,
                                                      1 G, 2 G possible
                                                                                normal operation                   22                           3 D required,
                                                                                                                                                       1 D, 2 D possible
                                                                                                                                                                                   normal operation                                  IIIC                 conductive dust                                                          conform to 2014/34/EU
    Marking of an associated apparatus (for example):                                                                                              Marking of an intrinsically safe apparatus acc. to ATEX (for example):                                                                 The first definition of a simple intrinsically safe circuit requires to observe all electrical limit values
                                                                                                                                                                                                                                                                                          stated in the EC type examination certificate and the power characteristics. If these conditions are
            [                                                                                                          IIC
                                                                                                                                                                                                                                                                                          met, the user is entitled to keep a proof of intrinsic safety. Inductances and capacitances of the in-
                                       Ex                   ia                  Ga                    ]                                             É                            II                                             1                                G                        stalled cables must be taken into account.
         associated            conform to                  type of             equipment         associated     Explosion group                     symbol            all areas except mining                  very high safety level suited         explosion protected against          Intrinsic safety of a simple circuit is given, if the following conditions are met (application of the
         apparatus              European                 protection            protection        apparatus                                                                   (mining = I)                     for zone 0 (two independent                 gas, vapour and mist            50 % rule for accumulated reactances):
                                standard                                       level (EPL)                                                                                                                         means of protection)                      (D = dusts)
                                                                                                                                                     Additionally, the year of production and the constructional level of safety must be contained in the                                   Associated ap-                    Condition                                      intrinsically safe equip-
                                                                                                                                                                                              device’s marking.                                                                             paratus                                                                          ment + cable
ATEX directive
EC type examination certificate                                                                                                                                                                                                                                                             U0                                            ≤                                  UI
    Marking of the EC type examination certificate acc. to ATEX:                                                                                   Marking of an associated apparatus acc. to ATEX (for example):                                                                            I0                                           ≤                                  II
          PTB                                    13                ATEX                      2013                      X                            É                     II                          (                         1                    )                  G                   P0                                            ≤                                  PI
    authorised body                         year of issue              acc. to            serial certificate   special conditions
                                                                      2014/34/EU              number                                                symbol          all areas except           associated              very high safety          associated       explosion pro-
                                                                                                                                                                         mining                 appartus                level suited for          appartus        tected against             L0                                           ≥                                  LI + LC
                                                                                                                                                                      (mining = I)                                        zone 0 (two                            gas, vapour and
                                                                                                                                                                                                                         independent                                   mist                 C0                                            ≥                                  CI + CC
Complete marking (for example)                                                                                                                                                                                           means of pro-                              (D = dusts)
Legal and technical marking                                                                                                                                                                                                 tection)
                                                                                                                                                                                                                                                                                          The cable characteristics provided by the manufacturer should be used. Should these not be avail-
                                                                                                                                                                                                                                                                                          able, it is recommended to apply the following typical values (acc. to EN 60079-14):
    In summary, an intrinsically safe equipment for use in Zone 0 has the following complete
    marking:                                                                                                                                       Preconditions for an explosion                                                                                                         LC = 1 µH/m (30 µH/W)
          II                  1                    G               Ex                ia            T6*)              Ga
                                                                                                                                                                                                                                                                                          CC = 200 pF/m
                                                                                                                                                                                                            Ignition triangle                                                             Connection of proximity switches to isolating switching amplifiers, or 2-wire transmitters to isolat-
* ) On equipment for use in dust explosion hazardous areas here the maximum                                                                                                                                                                                                               ing transducers, or solenoid valves to a valve control module can be considered as simple circuits.
surface temperature e.g. T140° is specified.
                                                                                                                                                                                                                                                                                          General guidelines for the use of devices with intrinsically safe circuits
    In summary, an intrinsically safe equipment for use in Zone 0 has the following complete                                                                                Sources of ignition:                                                                                          It is required to observe a safety distance of 3 mm (EN 60079-11) to earthed components, such
                                                                                                                                                                            • hot surfaces
    marking:                                                                                                                                                                                                                                                                              as covers or side panels of mounting cabinets. A thread measure of 50 mm must be observed be-
                                                                                                                                                                            • flames and hot gases                                Oxidizers:
                                                                                                                                                                            • mechanical sparking                                 • air (21 % oxygen)                                     tween intrinsically safe connections and non-safe connections.
                                                                                                                                                                                                         flammable concentrations of                                                                                                  NO
                                                                                                                                                                                                                                                                                                                                    1 off
                                                                                                                                                                                                                                                                                                                                                    NC
                                                                                                                                                                                                                                                                                                                                                    WB
                                                                                                                EN 60079-0 comprises general regulations on the construction and testing of electrical equipment for use in explosion
                                        General requirements                          EN 60079-0
                                                                                                                hazardous areas.
                                                                                                                                                                                                                                                                                     Ignition temperature and classification of combustible
                                                                                                                                                                                                                                                                                     materials according to groups and temperature classes
                                                                                                                In the case of ignition inside the encapsulation, the enclosure must withstand the pressure, and a transfer of the                                             1     (I = mining areas susceptible to fire damp II = all other atmospheres)
                         
                                        Flameproof enclosure (d)                      EN 60079-1
                                                                                                                "inner" explosion to the outside must be ruled out.                                                                                                            2
                                                                                                                                                                                                                                                                                      450 °C                                                            Maximum surface temperature of apparatus
                                        Presurised enclosure                          EN 60079-2                A protective gas, which is under overpressure, (min 0.5 mbar) encloses and separates the ignition source from the
                                                                                                                                                                                                                                                                               2
                                        (p) (pD2) (px) (py) (pz)                      EN 61241-4                surrounding atmosphere.
                                                                                                                The finely grained material encloses the ignition source. An electric arc generated in the inside of the housing must not be                                   1      300 °C
                                        Sand filling (q)                              EN 60079-5
                                                                                                                capable of igniting the potentially explosive atmosphere during normal operation.                                                                              2
                                                                                                                                                                                                                                                                                      200 °C
                                                                                                                Protection type „oil immersion“ implies that the electrical apparatus and its components are separated from the potentially                                    1
                                        Oil immersion (o)                             EN 60079-6
                                                                                                                explosive atmosphere by immersion in oil.                                                                                                                      2
                                                                                                                                                                                                                                                                                      135 °C
                                                                                                                                                                                                                                                                                      100 °C
                                                                                                                This protection type ( e ) applies only to electrical equipment and its components which is incapable of generating danger-
                                                                                                                                                                                                                                                                               1          85 °C
                                        Increased safety (e)                          EN 60079-7                ous sparks, electrical arcs or thermal effects during normal operation. The voltage rating of this type of equipment may not
                                                                                                                                                                                                                                                                               2
                                                                                                                exceed 11 kV.
                                                                                                                                                                                                                                                                               0                                   T1              T2                                       T3                  T4                  T5   T6
                                                                                                                The energy in the current circuit is limited to such an extent that sparks, electrical arcs or high temperatures cannot be
                                        Intrinsic safety (ia) (ib) (ic)               EN 60079-11                                                                                                                                                                              1      I                            Methane
                                                                                                                generated.
                                                                                                                                                                                                                                                                               2
                                                                                                                                                                                                                                                                                      IIA                          Aceton          Butane                                   Benzines
                                                                                                                                                                                                                                                                                                                   Ammonia         Butanol                                  Diesel
                                                                                                                Sparking is excluded. Clearances and creepage distances are determined. Maximum surface and component temperatures                                                                                 Amyl Acetate    Ethanol                                  fuel
                                                                                                                are limited.                                                                                                                                                                                       Benzene                                                  Hexane
                                        Non sparking apparatus (nA)                   EN 60079-15                                                                                                                                                                              2
                                                                                                                The protection degree of the housing has to be at least IP54/IP44.                                                                                                                                 Acetic Acid
                                                                                                                Area of application: zone 2.                                                                                                                                                                       Ethane
                                                                                                                                                                                                                                                                                                                   Ethyl acetate
                                                                                                                                                                                                                                                                                                                   Carbon
                                                                                                                The protection type applies to sparking equipment, in which contacts are appropriately protected by:                                                                                               monoxide
                                                                                                                – enclosed switching device                                                                                                                                                                        Methane
                                        Sparking apparatus (nC) (nR)                  EN 60079-15               – enclosed i.e. sealed equipment                                                                                                                               2                                   Methanol
                                                                                                                – hermetically sealed housing.                                                                                                                                                                     Propane
                                                                                                                Area of application: zone 2.                                                                                                                                                                       Toluene
                                                                                                                Distinguished are:
                                                                                                                - certified intrinsically safe systems                                                                                                                         0
                                        Intrinsically safe electrical                                           - certified intrinsically safe systems
                                                                                      EN 60079-25                                                                                                                                                                              1
                                        systems (ia) (ib) (ic)
                                                                                                                                                                                                                                                                               2
                                                                                                                An intrinsically safe system is the approved assembly of interconnected electrical equipment (intrinsically safe and associ-
                                                                                                                ated apparatus). It is documented accordingly in the system description.
                                        Optical radiation
                                        (op pr) (op sh)
                                                                                      EN 60079-28
                                                                                                                The optical radiated power is limited so that it is incapable of igniting an explosive
                                                                                                                atmosphere.
                                                                                                                                                                                                                                                                               1
                                                                                                                                                                                                                                                                               2
                                                                                                                                                                                                                                                                                                      www.turck.com
                                                                                                                                                                                                                                                                                                      Hans Turck GmbH & Co. KG
                                                                                                                                                                                                                                                                                                      Witzlebenstr. 7
                                                                                                                                                                                                                                                                               20                     45472 Muelheim an der Ruhr
                                       Protection by housing                                                   The enclosure is so dense that no combustible dust can enter it.                                                                                               21                     Germany
                                                                                      EN 60079-31
                                        (t2,) (ta) (tb) (tc)                                                    The surface temperature of the outer enclosure is limited.                                                                                                     22                     Tel.	    +49 208 4952-0
                                                                                                                                                                                                                                                                                                      Fax	     +49 208 4952-264
                                                                                                                                                                                                                                                                                                      E-Mail	more@turck.com
) Application in dust areas
2
                                                                                                                                                                                                                                                                                                      D200457 2014/04_V1.2
                                                                                                                                                                                                                                                                                                      Subject to change without notice          ●    Edition 04.14           ●    © Hans Turck GmbH & Co. KG 2014